Description

V1/50 /4”– 4”/ 20–120 mm grouting thickness.


V1/10 < 1 /16”/ < 30 mm grouting thickness.
V1/160 > 4”/ > 100 mm grouting thickness.
• High flowability, even after 90 minutes.
• Cement-based and chloride-free.
• Controlled and even expansion with a rigid bond between concrete foundation and machine
base plate.
• High early and final strength.
• Low modulus of elasticity in connection with high bending strength.
• Resistant to cracks even when prepared with a low water/cement ratio (0.36-0.38).
• Resistant to freeze/thaw cycles, waterproof, resistant to oil and petrol.
• Pumpable and easy to pour even during low temperatures.
• Good for use in drinking water areas.

Recommended Uses

• Universal grout for precision machines of all kinds.


• Turbines, generators, compressors, diesel engines and other power equipment operating
with heavy vibration.
• Anchor screws, levelling units and sole plates.
• Steel and concrete columns.
• Pre-fabricated concrete units and structural steel works.
• Bridge bearings and construction joints.
• Crane rails and radio telescopes.
• Steel and blast-furnace plants as well as mines.

ADM
A IDXMT U
I XRTEUS R E S
SPECIAL ADMIXTURES
SPECIAL ADMIXTURES
S U R FA C E I M P R O V E M E N T
SURFACE IMPROVEMENT
GROUTS
GROUTS
WAT E R P R O O F I N G
WATERPROOFING
FLOORING
FLOORING
I N D U S T R I A L C O AT I N G S
INDUSTRIAL COATINGS
JOINT SEALANTS
JOINT SEALANTS
R E PA I R / C R A C K I N J E C T I O N

T I LR
I NEGP S
A YI RS /TCE RMAS C K I N J E C T I O N

TILING SYSTEMS
Technical Data

TYPE V1/10 V1/50 V1/160


Aggregate Size Inch 0 - 0.04 0 - 0.02 0 - 0.63
mm 0-1 0-5 0 - 16

Grouting Height Inch 0.20 - 1.18 0.79 - 4.72 3.94


mm 5 -30 20 - 120 >100
Amount of water % 12-13% 3 ¼ - 3½ 10-12% 4 - 4¼ 11%-25/8 - 3
QTS(3-3.25L) QTS(3.25-4L) QTS(2.5-2.75L)
Material Needed (dry mortar) Kg/dm3 2.0 2.0 2.1
Density of freshly mixed mortar at 20 C
O Kg/dm3 2.28 2.3 2.33
Workability Immediately Min. >90 >90 >90
Flowability (channel) 60 Min. inch (cm) 21.65 (55) 21.65 (55) -
Immediately inch (cm) 20.47 (52) 17.71 (45) -
Measure of extention 60 Min. Vol. % - - 21.65 (55)
(DIN 1048) 24 h Vol. % - - 17.71 (45)
Extension 28 h PSI (MPA) + 0,5 + 1,0 + 1,0
24 h PSI (MPA) + 0,5 + 1,0 + 1,0
Compressive strength 7d PSI (MPA) 4,930 (34) 5,510 (38) 5,655 (39)
V1/10, V1/50:1.57 x 1.57 x 6.30 inch 28 d PSI (MPA) 6,960 (48) 8,120 (56) 8,120 (56)
V1/160: 3.943.943.94 inch 90 d PSI (MPA) 10,005 (69) 10,440 (72) 10,440 (72)
24 h PSI (MPA) 10,875 (75) 11,310 (78) 11,310 (78)
Bending strength 7d PSI (MPA) 652.5 (4.5) 797.5 (5.5) 797.5 (5.5)
1.57 x 1.57 x 6.3 inch 28 d PSI (MPA) 797.5 (5.5) 942.5 (6.5) 942.5 (6.5)
90 d 1,087.5 (7.5) 1,160 (8.0) 1,160 (8.0)
1,087.5 (7.5) 1,160 (8.0) 1,160 (8.0)
Pot Life at 30OC min 120 120 120
All test data are derived under normal climate conditions. 23/50-2

Visual Representation:

Development of compressive strength (V1/50)

Development of Expansion
Application Guidelines

Surface preparation:
Clean thoroughly, remove loose or unsound material and cement slurry by means of hydraulic
water-blasting or similar till carrying capacity of grain structure is reached. Prior to grouting,
the surface must be wetted continuously for approx. 6 hours till saturation.

Formwork:
Must be of rigid construction, with sand or dry mortar being placed around the concrete base
carefully to prevent leakage.

Mixing:
The grout is ready for use, only water is to be added (10–12 % or 2.5–3 l per bag). Measure
out the correct quantity of water and fill two thirds of this into a concrete mixer. Add the dry
mortar and mix for about 3 minutes. Then fill in the remaining water and mix for another 2
minutes. Grouting then should take place immediately.

Placing:
Place the mixed grout from one side or corner only in one continuous pour. When grouting
large areas, we suggest to pour starting from the middle – using a pipe or funnel. On machine
installations fill the anchor bolt pockets first (up to approximately top of anchor bolt pockets)
and then the underside of the machine. Open areas must be protected against wind, draught
and premature evaporation by using for example a plastic foil or VERTEX RockCure O2 Curing
Compound.

Grouting shoulders:
Height and shoulders around base plates must not exceed 2 inches or 50 mm.

Temperature:
Apply between 5°- 35°C. Low temperature working conditions retard the strength develop-
ment and reduce the flowability while high temperatures accelerate the same.

Non-Iron-Metals:
Cement as well as all cement-bound building materials may under certain circumstances
cause a coming-off of non-iron-metals in the application area (for example aluminum, copper,
zinc), please ask for our technical service.

Important Information:
Supplied in: 25kg Bag.

Storage: Dry, frost free area. Out of direct sunlight.

Yeild: 0.12 m3/bag.

Shelf life: 12 months.

Hazard Class: No dangerous goods.

The information provided in this leaflet is supplied by our consulting service and is the end result of exhaustive research and extensive
experience. However, it is without any liability on our part particularly regarding third party proprietary rights. This information does not
relieve the user of the responsibility for verifying that the products and processes are suitable for the intended application. The data
presented was derived from tests under normal climate conditions according to DIN 50014 and mean average values and analysis.
Deviations are possible when delivery takes place. Given the recommendations may differ from those shown in this leaflet, written
confirmation should be sought. It is the responsibility of the purchaser to ensure they have latest leaflet issue and that its contents are
current. Our customer service staff will be glad to provide assistance at any time. We appreciate the interest you have shown in our
products. This technical datasheet supersedes previously issued information.

VERTEX
C h em i ca ls (Pvt .) Lt d.
Plot # 1-A Misc Zone, Phone: +92 (0) 41 8507212-13
Value Addition City, Fax: +92 (0) 41 850 7214
Sahianwala Road Khurriawala, Email: [email protected]
Faisalabad, Pakistan. Website: vertexchemicals.pk