GENERAL NOTES AND SPECIFICATIONS
SECTION 1. ARCHITECTURAL WORKS
1.1 GENERAL NOTES AND SPECIFICATIONS 1.1.1 ROOFING SYSTEM AND CEILING A. USE A LIGHT-COLORED ROOF (PREFERABLY GREEN OR WHITE COLOR), SINCE A DARK- COLORED ROOF ABSORBS MORE HEAT FROM THE SUN. B. USE METAL FRAMING FOR THE DURABILITY OF THE TRUSSES. C. USE ASPHALT SHINGLE ROOF. D. APPLY ROOF INSULATION, THIS HELPS IN REDUCING THERMAL BRIDGING. E. HEIGHT OF CEILING FROM GROUND FLOOR TO SECOND FLOOR IS 3000 MM. F. HEIGHT OF CEILING FROM SECOND FLOOR TO ROOF BEAM IS 2700 MM. 1.1.2 WALLS A. FOR SOME AREAS IN THE EXTERIOR WALL, PUT SOME PLANTS TO LESSEN THE HEAT THAT COMES IN THROUGH THE WALL. B. PUT SOME WALL CLADDING (PARTICULARLY WOOD PANEL CLADDING) AND SOME PLANTS ON THE WALL TO ADD AESTHETIC, AND TO LESSEN THE HEAT ABSORPTION. C. USE COOL AND LIGHT COLORS FOR EXTERIOR WALL PAINT D. USE A WARM TONE ON THE INTERIOR WALL TO ADD COZINESS AND COMFORT. E. PUT TREES IN AN AREA WHERE THE SUNLIGHT HITS DIRECTLY TO THE WALL OR IN ANY FENESTRATION TO BLOCK HEAT NATURALLY. 1.1.3 DOORS A. MAHOGANY DOORS FOR THE MAIN DOOR FOR DURABILITY AND HAS LOW MAINTENANCE. B. FOR TOILET AND BATH DOORS, USE PLASTIC OR PVC, SINCE IT IS MORE EXPOSED TO WATER. C. STANDARD DIMENSIONS OF DOORS ARE AS FOLLOWS: MAIN DOOR 900 MM WIDTH, 2100 MM HEIGHT BEDROOM DOORS 800 MM WIDTH, 2100 MM HEIGHT TOILET AND BATH DOORS 600 MM WIDTH, 2100 MM HEIGHT 1.1.4 WINDOWS A. TEMPERED GLASS IS RECOMMENDED TO BE USED IN LARGE WINDOWS TO PREVENT BREAKING AND CAN WITHSTAND HEAVY WIND OR TYPHOON. B. GLAZING IS RECOMMENDED TO BE USED FOR WINDOWS SINCE IT HELPS TO RETAIN THE WARMTH DURING THE WINTER, AS WELL AS REDUCING THE REFLECTION OF HEAT DURING SUMMER. C. APPLY WINDOW TINT/FILM IN EVERY WINDOW GLASS TO BLOCK THE UV RAYS, AND HELPS IN REDUCING THE HEAT THAT COMES INTO THE HOUSE. D. FOR WINDOWS, USE SLIDING WINDOWS FOR ALL OPENINGS EXCEPT FOR THE TOILET AND BATH FOR BETTER AND NATURAL VENTILATION. E. MOUNTING HEIGHT OF ALL WINDOWS ARE 900 MM ABOVE THE FINISHED FLOOR LINE. F. STANDARD DIMENSIONS OF WINDOWS ARE AS FOLLOWS: SLIDING WINDOWS 1650 MM WIDTH, 1200 MM HEIGHT FIXED WINDOWS 1650 MM WIDTH, 1650 MM HEIGHT TOILET AND BATH WINDOWS 600 MM WIDTH, 600 MM HEIGHT 1.1.5 FINISHING WORKS A. PAINTING 1. PRIOR IMMEDIATELY AFTER STEEL WINDOWS AND DOORS HAVE BEEN ERECTED AND BEFORE GLAZING, ONE COAT OF OIL-BASE OR METAL PROTECTIVE PAINT SHALL BE APPLIED. A SECOND COAT SHALL BE APPLIED AFTER PUTTY HAS DRIED AND SORT, NOT SOONER THAN THREE WEEKS AFTER GLAZING. 2. ALL DOORS AND WINDOWS SHALL RECEIVE ONE COAT OF RUST RESISTING PRIMING PAINTS. 3. FOR PAINTING OF INDOOR AND OUTDOOR DRYWALL, USE TWO COATS OF SYNTHETIC LATEX BASED, WEATHER RESISTANT PAINT.
SECTION 2. STRUCTURAL WORKS
2.1 GENERAL NOTES AND SPECIFICATIONS 2.1.1 MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE FOLLOWING BUILDING CODE A. ACI 318-19 B. AISC 2011 C. NSCP 2015 2.1.2 CONCRETE AND MASONRY WORKS A. CONCRETE MIXTURES TO BE USED IN THIS PROJECT ARE THE FOLLOWING: CLASS A - FOR COLUMNS, BEAMS, FOOTINGS AND TIE BEAMS CLASS B - FOR WALKS, DRIVEWAYS, HOLLOW BLOCKS MORTAR, FILLER AND PLASTERING CLASS C - FOR FLOOR AND SLABS ON FILL B. USE 3000 PSI CONCRETE FOR FOOTINGS, COLUMNS, BEAMS, AND ALL CONCRETE SLABS AND 2500 PSI FOR SLABS ON FILL. C. CONCRETE HOLLOW BLOCKS TO BE USED IN THIS PROJECT ARE THE FOLLOWING: 6” x 8” x 16” CHB - TO BE USED FOR ALL LOWER AND UPPER EXTERIOR WALLS 4” x 8” x 16” CHB - TO BE USED FOR ALL INTERIOR WALLS D. SPECIFIED CURING TIME FOR THE REMOVAL OF FORMS: SUSPENDED SLABS 28 DAYS BEAMS 28 DAYS COLUMNS AND WALLS 3 DAYS FOUNDATIONS 3 DAYS 2.1.3 REINFORCEMENT AND STEEL WORKS A. STEEL REINFORCEMENTS TO BE USED IN THIS PROJECT ARE THE FOLLOWING: 1. 16 MM DIA. DEFORMED BAR - TO BE USED FOR COLUMN REINFORCEMENT 2. 16 MM DIA. DEFORMED BAR - TO BE USED FOR BEAMS AND FOOTINGS REINFORCEMENT AS WELL AS FOR FOOTING TIE BEAM 3. 10 MM DIA. DEFORMED BAR - TO BE USED FOR BEAMS STIRRUPS AND LATERAL TIES 4. #16 G.I. WIRE TO BE USED FOR ALL STEEL BAR INTERSECTIONS 5. GRADE 40 - 40000 PSI 2.1.4 FLOORING AND TILE WORKS A. THE FLOORINGS SHALL BE SUCH AS TO PROVIDE A PERMANENT SURFACE THAT CAN BE WALKED ON. B. MATERIALS FOR POLISHED CEMENT FLOORS SHALL CONSIST OF PORTLAND CEMENT TYPE 1 AND SAND. C. ALL TILES AND MOSAIC SHALL BE SET OR LAID PLUMB, IN TRUE ALIGNMENT AND HORIZONTAL OR AT THE SLOPE SPECIFIED, WITHOUT ANY PROJECTIONS, WITH REGARD TO ANY SPECIFIED REFERENCE AND LEVEL LINES. D. THE MORTAR COMPOSITION SHALL BE AS ONE PART OF CEMENT AND FOUR PARTS OF SAND. E. FOR THE SETTING AND LAYING OF GLASS TILES, GLASS WALL PANELS AND GLASS MOSAIC, THE MANUFACTURER’S PROCESSING INSTRUCTIONS SHALL BE OBSERVED. THE THICKNESS OF THE MORTAR BEDDING FOR TILE COVERINGS SHALL BE AT LEAST 10 MM, WITH AN AVERAGE OF 15 MM, UNLESS OTHERWISE SPECIFIED. F. ALL TILES FOUND TO BE HOLLOW WHEN TAPPED SHALL BE REPLACED. ALL SURPLUS MORTARS OR GROUTS SHALL BE REMOVED BEFORE THEY HAVE HARDENED. G. WHERE FLOOR DRAINS ARE PROVIDED, THE PLANES OF THE FINISHED FLOOR SHALL BE SLOPED TOWARDS THE DRAINS. H. TILES SHALL FIT CLOSELY AND NEATLY AROUND ALL PLUMBING FIXTURES AND AROUND ELECTRICAL OUTLETS. I. UPON COMPLETION OF THE WORK, ALL SURFACES OF CERAMIC TILES SHALL BE CLEANED WITH A SOAP POWDER AND CLEAN WATER.
SECTION 3. ELECTRICAL WORKS
3.1 GENERAL NOTES AND SPECIFICATIONS 3.1.1 ALL ELECTRICAL WORKS SHALL COMPLY IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE (PEC). THE RULES AND REGULATIONS OF THE LOCAL ENFORCING AUTHORITY AND THE REQUIREMENTS OF THE LOCAL POWER COMPANY. THE ELECTRICAL WORKS SHALL BE UNDER IMMEDIATE SUPERVISION OF A DULY REGISTERED ELECTRICAL ENGINEER. 3.1.2 THE ELECTRICAL SERVICE POWER IS 1-PHASE, 2 WIRE + GROUND 230 V, 60 HZ. 3.1.3 CONDUITS SHALL HAVE A MINIMUM OUTSIDE DIAMETER OF 20 MM ELECTRICAL SIZE PER PEC. AS NECESSARY, PROVIDE CONDUIT SIZE IN COMPLIANCE WITH MAXIMUM CONDUIT FILL ALLOWED BY THE PEC. 3.1.4 MINIMUM SIZE OF CONDUCTOR TO BE USED FOR LIGHTING AND CONVENIENCE CIRCUITS SHALL BE 2.00 MM SQ. STRANDED CONDUCTOR. 3.1.5 ALL CONDUITS INSTALLED SHALL BELOW GROUND OR EMBEDDED IN FLOOR OR WALL SHALL BE PVC. 3.1.6 MOUNTING HEIGHT OF DEVICES SHALL BE AS FOLLOWS: WALL SWITCHES 1.30 M ABOVE THE FINISHED FLOOR LINE CONVENIENCE OUTLET 0.30 M ABOVE THE FINISHED FLOOR LINE PANEL BOARD 1.80 M ABOVE THE FINISHED FLOOR LINE FIRE ALARM OUTLET 1.50 M ABOVE THE FINISHED FLOOR LINE 3.1.7 TOP OF PANEL BOARDS SHALL BE NOT MORE THAN 1.8 M ABOVE FINISHED FLOOR PLAN. 3.1.8 SIZES OF WIRES SHALL BE INCREASED BY ONE SIZE IF HOME RUN IS MORE THAN 30 METERS. 3.1.9 ALL MATERIALS USED FOR INSTALLATION SHALL BE BRAND NEW AND FREE FROM ALL DAMAGE. 3.1.10 ALL NON-CURRENT METAL PARTS OF EQUIPMENT/SERVICES SUCH AS PANEL BOARD AND THE LIKE SHALL BE PROPERLY GROUNDED IN ACCORDANCE WITH THE PROVISIONS OF ARTICLE 4, PEC. 3.1.11 NO ALTERATION SHALL BE DONE IN THE PLAN UNLESS NOTED BY THE DESIGNER AND OWNER. 3.1.12 ALL ELECTRICAL WORKS/INSTALLATIONS SHALL BE DONE IN STANDARD WORKMANSHIP MANNER WITH SKILLED MANPOWER AND DULY SUPERVISED ELECTRICAL ENGINEER.
SECTION 4. PLUMBING WORKS
4.1 GENERAL NOTES AND SPECIFICATIONS 4.1.1 ALL PLUMBING WORKS TO BE DONE AND SIZES OF THE PIPES TO BE USED SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF UNIFORM PLUMBING CODE OF THE PHILIPPINES AND LOCAL REGULATION AND ORDINANCES. 4.1.2 ALL PIPES SHALL BE INSTALLED AS INDICATED IN THE WORKING DRAWINGS. ANY RELOCATION REQUIRED FOR PROPER EXECUTION OF OTHER TRADES SHALL BE UPON APPROVAL OF SANITARY ENGINEER. 4.1.3 ALL PIPES SHALL BE PROVIDED BY PROPER HANGER AND SUPPORT. 4.1.4 ALL FIXTURES SHALL BE VENTED INDIVIDUALLY AND WATER LINES SHALL BE VALVE BY GROUP. 4.1.5 ALL PLUMBING FITTINGS SHALL BE ACCESSIBLE FOR MAINTENANCE. PROVIDE MANHOLE IF SUCH INSTALLATION ARE INSIDE THE CEILING. 4.1.6 ALL CHANGES IN DIRECTION SHALL BE MADE BY THE APPROPRIATE USE OF FORTY FIVE (45) WYE LONG SWEEP QUARTER BEND. ONE EIGHT WHEN THE CHANGE OF FLOR IS FROM HORIZONTAL TO VERTICAL. A SINGLE BEND COMBINATION MAY BE USED ONLY ON VENT PIPE. 4.1.7 NO DOUBLE HUB OR DOUBLE TEE BRANCH SHALL BE USED ON HORIZONTAL SOIL AND WASTE LINES. 4.1.8 PROVIDE PIPE SLEEVES AT WALL COLUMNS OR SLAB TO PROTECT FROM BREAKAGE. 4.1.9 ALL SLOPES FROM HORIZONTAL DRAINAGE PIPES SHALL MAINTAIN 1% UNLESS OTHERWISE SPECIFIED. 4.1.10 THE BRAND AND OTHER DETAILED PLUMBING FIXTURES SHALL BE IN ACCORDANCE WITH THE SCHEDULE FURNISHED BY THE ARCHITECT. 4.1.11 GATE VALVE SHALL BE BRONZE BODY, SOLID WEDGE TYPE, SCREWED OR FLANGED END. 4.1.12 USE UPLASTICISED POLYVINYL CHLORIDE (uPVC) FOR ALL WATER PIPING SYSTEM. 4.1.13 USE uPVC SANITARY PIPING SYSTEM 1000 FOR 100 ⌀ AND SMALLER AND SBR-34 GRAVITY SEWER MAIN uPVC PIPING SYSTEM FOR 150 ⌀ AND BIGGER. 4.1.14 ENGINEER-IN-CHARGE TO VERIFY ACTUAL LOCATION AND ELEVATION OF STREET DRAINAGE, STREET SEWER AND STREET WATER MAINS FOR CONNECTION BEFORE CONSTRUCTION.