0% found this document useful (0 votes)
16 views

How to Design Cascade Aerators - Netsol Water

Uploaded by

Minoosh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views

How to Design Cascade Aerators - Netsol Water

Uploaded by

Minoosh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

 For Enquiry- 0120-2350053 || +91 9650608473 || +91 9650795306  enquiry@netsolwater.

com     

HOME ABOUT US PRODUCTS KNOWLEDGE CENTER CLIENTS RESOURCES CONTACT

GET A QUOTE!

How to Design Cascade Aerators?


In most cases, water may be treated in treatment facilities to remove dangerous contaminants!

Pretreatment, aeration, coagulation, flocculation, sedimentation, filtration, fluoridation, conditioning, reverse osmosis and
disinfection are all part of the treatment process.

Cascade aerators are effective in increasing the dissolved oxygen level of water, removing CO2, and contributing significantly to
water self-purification due to an increase in DO, which speeds up the breakdown of organic materials.

At a treatment facility, aeration is frequently the first important step.


Constituents are eliminated or changed during aeration to prevent them from interfering with the treatment process. Aerators are
all designed to increase the amount of contact between air and water in order to improve gas transport and oxidation. As a result,
the dirty supply of water has a higher purity percentage of 60 to 70 percent.

Various types of aerators are used to carry out the aeration process.

1) Spray Aerators.

2) Air Diffuser basins or Diffused Aerators.


3) Gravity Aerators, which include,

a) Multiple Tray Aerator b) Cascade Aerator c) Slopping Tray Aerator d) Inclined Apron Aerator

What are Cascade Aerators?


A cascade aerator (one of the most frequent and oldest kind of aerator) is made up of a sequence of steps through which water
flows (similar to a flowing stream). Aeration takes place in the splash zones of all cascade aerators. Blocks are placed over the
slope to form splash zones. These can be used to oxidize iron and decrease dissolved gases to some extent.

Design Criteria’s for the Design of Cascade Aerators


Area required for Design of Aerator = 0.015 – 0.045 m2 /m3 /hr.

No. of cascade = 3 to 9.

Height of aerator = 1 to 3m.

Rise of each step = 20 to 50 cm.

Velocity of inlet pipe = 0.3 to 0.9 m/s

Let us understand this with the help of an example which will give you a clear designing procedure

Design a Cascade Aerator for inflow of 12 MLD. Assume other data suitably.
A. Design of Inlet pipe:-
Flow = Q = 12 MLD = (12 x 106 x 10-3)/ (24 x 60 x 60) = 0.138 m3 /s

Assuming velocity through pipe = 0.6 m/s.

Area of inlet pipe = (Q/v) = 0.138 / 0.6 = 0.23 = (Π/4)dp2,

Where, dp = Diameter of Inlet Pipe =0.6m

B. Design of Aerator:-
Assuming Area required for Design of Aerator = 0.030 m2 /m3 /hr.

Q = 12 MLD = 500 m3 /hr.

Area of Bottom Cascade aerator = 0.03 x 500 = 15 m2.

Total area of bottom cascade aerator = Area of bottom aerator + Area of inlet pipe

= 15 + {(Π/4)0.62} = 15.28 m2.

Total area of bottom cascade aerator =15.28 m2

Assuming no. of steps = 5

Diameter of bottomCascade: (Π/4)dx52 = 15.28 m2x d5 = 4.5 m

Now, assuming Height of Aerator = 2m

Rise of each step 2/5 = 0.4m

Diameter of 4th Cascade Aerator:- (4.5 / 2) = d4 / (2 - 0.4) d4 = 3.6 m

Diameter of 3rd Cascade Aerator :- (4.5 / 2) = d3 / (2 - 0.8) d3 = 2.7 m


Diameter of 2nd Cascade Aerator :- (4.5 / 2) = d4 / (2 – 1.2) d2 = 1.8 m

Diameter of 1st Cascade Aerator :- (4.5 / 2) = d3 / (2 – 1.6) d1 = 0.9 m

C. Design of Collecting Channel:-


Diameter of Collecting Channel = 4.5 + 1 + 1 =6.5m

q = Q / 2 = 1.375 b x h (3/2)

Where, q = discharge through channel in m3/s

b = width of channel in m

h = height of channel

→ q= 0.138 / 2 = 1.375 x 1 x h (3/2) h = 0.14 m

What can we offer?


Netsol Water is one of India's major water and wastewater management company, specialized in the design, manufacture, and
delivery of custom-made treatment systems, industrial machinery, and luxury amenities for the water industry.

We manufacture top-of-the-line WWTPs/ WTPs/ STPs/ ETPs/ RO-Plants/ Water-Softeners, among other services, which are
effective in removing high concentration of pollutants from industrial and commercial wastewater.

Netsol Water is Greater Noida-based leading water & wastewater treatment plant manufacturer. We are industry's most
demanding company based on client review and work quality. We are known as best commercial RO plant
manufacturers, industrial RO plant manufacturer, sewage treatment plant manufacturer, Water Softener Plant
Manufacturers and effluent treatment plant manufacturers. Apart from this 24x7 customer support is our USP. Call on +91-
9650608473, or write us at [email protected] for any support, inquiry or product-purchase related query.

Enquire Now

Your Name

Phone

Email

Message
SUBMIT NOW

Related Blog List

 Top 10 Commercial RO Plant Manufacturers in Ghaziabad

 Washing your food with RO water

 Control of odor and taste using RO system

 Choosing the right type of water softener

 How can WWTP preserve environment

 View All Blogs

Popular Products

Sewage Treatment Plant Sewage Treatment Plant Manufacturer Effluent Treatment Plant

Effluent Treatment Plant Manufacturer Industrial RO Plant Commercial RO Plant Manufacturer

Water Treatment Solutions

Email address to subscribe SUBSCRIBE      


COPYRIGHT © 2024 NETSOL WATER SOLUTIONS PVT. LTD. - WATER TREATMENT COMPANY DELHI/NCR. ALL RIGHTS RESERVED.

You might also like