Fig 3

CONTROL PANEL 1418-2-1517


CONTROL PANEL 3 2 5 1

MOUNTING
The control panel is splash proof and may be mounted in the damp
area adjacent to the cabin. The thermostat sensor must be wall
mounted within the sauna. Please follow the measurements in the 1. Thermostat
heater instructions to avoid the possibility of scorching the wood. 2. Timer
3. Pilot lamp
4. Space for connection
TIMER 5. Sauna light
The timer (2) is the main on/off switch for the controlpanel. To switch
on, turn knob clockwise: The scale provides first a 1-4hr working band,
then a 1-8hr preset band, which delays the switch on time. The pilot
light (3) shows when the heater is on.

When the sauna is finished, the timer knob may be turned back to the
off position or left to switch off automatically at the end of the set
working time. 4

REGULATION OF TEMPERATURE
The thermostat control (1) regulates temperature. Turn clockwise to
achieve stepless increase of temperature level in the sauna. Reset-
ting the thermostat each time the sauna is used is unnecessary.
When the position which maintains the desired temperature has 1 Blue
been found, the knob may be permanently left at this setting. 2 White
3 Red
4 Yellow
LIGHT SWITCH
A rocker-switch (5) is provided for connections to the light fitting in the
sauna

SENSOR UNIT
The recommended mounting dimensions for the sensor are shown in
the heater instructions. A 3 metre lenght of heat- resistant cable
(170 C) 4 x 0,5mm - is provided. This may be extended with normal
low voltage cable Outside the sauna cabin. Connection details for
the sensor are shown in fig. 4. Front side Back side
LIMIT CONTROL
If the temperature in the sauna should rise too high (for example due
to a thermostat fault) the limit switch in the sensor will turn off the
ot2ps
power. When the fault has been rectified the switch may be reset. 314 SYOT 32 B
7014293
- Sensor installation

The sensor must be installed as shown in the illustration below.


Digression from these instructions may cause overheating and
risk for fire
Sensor

(mm) 40 (mm)
F

D
A A
min 30 min 30
min 1900

min 20
min 20

- Removing of the cover


Heater Distance (mm)

kW A D F

3,0 30 50 1200
4,5 50 80 1200
6,0 70 100 1250
8,0 100 150 1250
9,0 100 200 1250