ANNUNCIATOR MODEL CODE DEFINITION

Series 90A Model Number


90A- - - - - - -
______ ______ _____ _____ _____ _____ _____
Item 1 Item 2 Item 3 Item 4 Item 5 Item 6 Item 7
Mounting # of Cells # of Cells Common Window Active Window
Options High Wide Service Size Points Color

- - - - - - -
_____ _____ _____ _____ _____ _____ _____
Item 8 Item 9 Item 10 Item 11 Item 12 Item 13 Item 14
Operational Repeat Power Field Contact Window Comm. Options
Sequence Relay Input Voltage Legends Options

Example: 90A-PM-3H-6W-INTB-2-34-W-A-RR-B-X-TP-MB-TS-IB-RLY

Item 1 Mounting Options Item 8 Operational Sequence


PM Semi-Flush Panel Mounting A; A4; A4-5-6; M; R; R-12 ; F1A; F2A; F3A; F2M-1;
PC Semi-Flush Panel Mounting w/rear cover FFAM2; F3C ; R12C ; RC
RK 19” Rack Mounting (5 wide systems only) IMO Intermixed Sequences (up to 4 available)
S Surface (Wall) Mounting (1H to 5H x 2W to 5W)
N4 Nema-4 Enclosure (3H to 5H x 3W to 5W)
Item 9 Repeat Relay Option
RR Auxiliary Repeat Relay Provided for every Input.
Item 2,3 Annunciator Size (Can be field configured to follow: alarm input status,
alarm sequence operation or Lamp Flash. Relays
can be set for normally energized or de-energized
# of Cells High # of Cells Wide operation and are jumper selectable for a Form A or
(1-13) (2-13) Form B contact arrangement).
FRC Auxiliary Repeat Relay Provided for every Input with
Form C (SPDT) Contacts.
Item 4 Common Service Cell (lower right cell) (Can only be used with Window Size 1E or 2S).
INTB Integral Pushbuttons (ACK, SIL, TEST, RESET) 2RR Two Repeat Relays for every input.
NPB Pushbuttons replaced w/ a Half or Full Size Window (Selectable for a Form A or Form B contact
Note: For either selection above, external pushbuttons can arrangement. Can only be used with Window
be connected to the Annunciator terminal blocks. Size 1E or 2S.)
NR No Repeat Relays required
(Note: Can only choose one selection from above).
Item 5 Window Size
4 Quad Size, 4 inputs per cell, ea 1.5”H x 1.5”W
3 Third Size, 3 inputs per cell, ea 1.0”H x 3.0”W Item 10 Power Input
2E Half Size, 2 inputs per cell, ea 1.5”H x 3.0”W F 24 VDC
2S Half Size, 2 inputs per cell, ea 1.5”H x 3.0”W E 48 VDC
2 Half Size, 2 inputs per cell, ea 1.5”H x 3.0”W C 125 VDC
1E Full Size, 1 input per cell, ea 3.0”Hx3.0”W B 120 VAC, 60 HZ
IMW Intermixed window size A 230 VAC, 50 HZ
Note:
Option 1E indicates that the cell is expandable up to 2 inputs.
Option 2E indicates that the cell is expandable up to 4 inputs. Item 11 Field Contact Voltage (FCV)
Option 2S indicates one input module per single input provided. Field Contact Voltage internally supplied by AMETEK, with
Do not include the CSM Cell in your quantity. common system-wide FCV return.
*For System Input Power Voltages of 120/230VAC or 125VDC.
D 125 VDC FCV
Item 6 Active Points X 24 VDC FCV
Total # of active points Field Contact Voltage externally supplied by Customer, internally
bussed to all input modules.
DC 125 VDC FCV supplied by Customer
Item 7 Window Color TC 48 VDC FCV supplied by Customer
XC 24 VDC FCV supplied by Customer
W White Window Filter
JC 12 VDC FCV supplied by Customer
R Red Window Filter
Field Contact Voltage externally supplied by Customer.
A Amber Window Filter
Every input is isolated and requires a separate FCV connection.
G Green Window Filter
D/ISO 125 VDC FCV supplied by Customer
B Blue Window Filter
T/ISO 48 VDC FCV supplied by Customer
IMC Intermix color, matrix must be included
X/ISO 24 VDC FCV supplied by Customer

SERIES 90A ANNUNCIATOR INSTALLATION AND CONFIGURATION MANUAL 12


J/ISO 12 VDC FCV supplied by Customer SER Time Stamping of alarms.
Y/ISO 120 VAC FCV supplied by Customer (The Time & Date of each alarm is recorded to the
NR No Field Contact Voltage (Serial Input Only) msec. The Time Stamp output can be selected as
Serial ASCII Data to a printer or terminal [must
select option SD], Modbus [must select option MB]
Item 12 Window Legends or DNP [must select option DNP]. The 1 msec input
TP Legends printed on Transparency Film (field response [option FR] is included).
changeable)
E Legends Engraved on Windows IB IRIG-B Time Sync Input (used with SER Option)
Note: Window engraving or printed legends can be provided (Standard BNC Input)
at the factory at no charge if provided 1 week before
shipment. SP Serial Printer used for Time Stamped Alarms
(Used with SER option [time stamped alarms] and
SD option [serial data output]. Modbus, DNP and
Item 13 Serial Communications Ethernet are not available when selecting this.)
SIM Modbus Serial Input Only (no Field Contact Inputs) GF Ground Fault Detector (internally mounted)
SID DNP Serial Input Only (no Field Contact Inputs)
MB Modbus Communications, Transmit or Receive RLY Additional Two CSM Common Relays
DNP DNP 3.0 Communications, Transmit or Receive (System includes 2 CSM Common Relays
SD Serial ASCII Data Output of Time Stamped Alarms configurable for Critical or Non-Critical Horn,
(Used with the Time Stamping option SER only.) Ringback Horn. The additional 2 CSM Common
Note: Can only select one of the above options. Relays can be configured for additional horns or
All options above are field selectable for RS-232 or Critical/Non-Critical Reflash or Fault, Power Fail,
RS-485 and can be configured for Master or Slave System Watchdog, or Ground Fault Detect)
operation.
SW External Inhibit Switch Input
(Software configurable for inhibit of LED Lamps,
Item 14 Options Horn, Repeat Relay Outputs or CSM Common
Relay Outputs)
ETH Ethernet Port (RJ-45 , T1 connection)
(Used with Modbus or DNP Communication options. HN Internal Horn
Must select option MB or DNP. Replaces RS-
232/485 Serial Port.) AS Automatic Horn Silence
(Can be used to silence any horn with software
FR 1 msec Input Response (50 msec Standard) configurable delay up to 60 seconds, in 0.25 second
(This will capture alarms that last 1 msec or longer. increments)
If Time Stamping is required, select option SER
instead) FS Flash Synchronization. Synchronizes the flash rate
to remote displays. Needs to be specified for each
Annunciator that will be synchronized together.
(Requires wiring between Annunciator Systems.)
STM Moisture/ Fungus Proof Coating

SERIES 90A ANNUNCIATOR INSTALLATION AND CONFIGURATION MANUAL 13