FIRE HYDRANT
SYSTEM
A PRODUCT OF
www.sffecoglobal.com
SFFECO with its more than 30 years of experience
has always been a progressive organization that has
remained in the forefront of the fire fighting industry
with innovative, re-engineered and unique products.
HYDRANT CABINETS
Storz
**SF-F-06 (1676) 1676 mm 5’ - 6” 210 kg
4, 4-1/2, 5 NST
**SF-F-06 (1829) 1829 mm 6’ - 0” 215 kg Pumper connection
SF-F-06 UL/FM 3 2-1/2 1 250
or 5 nonthreaded
**SF-F-06 (1981) 1981 mm 6’ - 6” 224 kg Storz
SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0
Standard size - 2 number of 2-1/2" hose outlets, 1 Number of 4-1/2" Pumper connection.
* Standard Models ( Subject to stock availability). Other outlet sizes are available upon request only.
** Available upon customer’s request only.
*** Monitor elbow is not available in “FM”
Requirement :
1.All inspection should be according to the factory standard and relate inspection instruction.
{
2.Avoid scratch after assembly the hydrant in order to keep good surface quality. Note : Standard on flange
joint where mechanical
connection is available up
{
on request.
HYDRANT
DRY BARREL
OUTLET CONFIGURATION
Monitor Connection
Available in 3” & 4”
Hydrant with 2 hose Hydrant With 2 Hose Hydrant With 3 Hose Hydrant With 4hose
outlets, 0 pumper outlet. Outlets, 2 Pumper Outlet Outlets, 1 Pumper Outlet Outlets, 0 Pumper Outlet
*Standard size - 2 number of 2-1/2" hose outlets, 1 Number of 4-1/2" Pumper connection. And others are available up
on request only.
HYDRANT
DRY BARREL
KEY FEATURES
• LPCB Approved, Conforms to BS EN 14384: 2005, BS 1074-1, BS 1074-2 & BS 1074-6 Standards.
• Hydrant Available in 4” and 6” inlet size.
• Working pressure of 16 Bar and test pressure of 25 Bar as per BS EN 14384: 2005
• Flanges conforms to EN1092-2 Standard.
• Break away design to prevent accidents to the hydrants, where only the upper part of the flange would be
broken upon impact.
• Automatic drain system drains the water in the upper part when the main valve is closed, thus avoiding
damage caused by freezing.
• Hydrant Body (Lower, Middle and Upper body) is of ductile iron.
• Efficient hydraulic design provides optimum performance & maximum flow.
• Easily removable main valve from the ground line flange.
• Threaded & Field replaceable hose nozzles & pumper outlet
• Available with Different type of caps and outlet landing valves.
• Hydrants are designed for high performance and easy to install, maintain and repair.
• Painting: Inside surface coated with non toxic epoxy paint not less than 300 microns. Outer surface
above ground coated with epoxy paint not less than 300 microns (RAL 3000). Underground portion
coated with asphalt not less than 300 microns (RAL 9005).Other thickness & fusion bonded expoxy are
available upon request).
C GROUND LEVEL
B B
D D
HYDRANT
A
HYDRANT
A A
Notes:
1) Available with straight and
90 Deg Horizantal inlet,
with different dimension.
Description Lower Depth Hydrant Details 2) Standard Size For higher depth
hydrant: 2 nos. of 2.5” BSP Description Higher Depth Hydrant Details.
Model SFH100-LPLD SFH150-LPLD hose outlets & 1 no. of 4” BSP
SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0
HYDRANT WITH LANDING VALVE HYDRANT WITH CAP HYDRANT WITH CAP HYDRANT
WITH LANDING VALVE
LOWER DEPTH HYDRANT DETAIL LOWER DEPTH HYDRANT DETAIL HIGHER DEPTH HYDRANT DETAIL
MODEL MODEL
SFD-250-WH SFD-250-WH
Flanged Head Closed Head
Ø229
All Dimensions are measured in MM
95
135
663
720
360
Ø279
Ø279
4 NST Pumper
SFD-250-WH UL/FM 1 2-1/2 1 250
Connection
Standard size - 2 number of 2-2/1 " hose outlets, 1 Number of 4-1/2" Pumper connection.
Other optionals are available upon request.
HYDRANT
WET BARREL
OUTLET CONFIGURATION
KEY FEATURES
• New Developed with built-in ball valve and standard straight valve.
• Hydrant Available in 4” and 6” inlet size.
• Working pressure of 16 Bar and test pressure of 25 Bar.
• Flanges conforms to BS4504 Standard (ANSI/DIN Flange Available upon request)
• Break away design to prevent accidents to the hydrants, where only the upper
part of the flange would be broken upon impact.
• Automatic drain system drains the water in the upper part when the main valve is
closed, thus avoiding damage caused by freezing.
• Hydrant Body (Lower, Middle and Upper body) is of ductile iron. (Cast iron
available up on request)
• Efficient hydraulic design provides optimum performance
& maximum flow.
B
• Easily removable main valve from the ground line flange.
• Hydrants are designed for high performance and easy to
install, maintain and repair.
• Painting: Buried part surface with RAL 9005 black paint,
GROUND LEVEL
outside surface with RAL 3000 Paint.
• Approved by Royal Oman Police & PAWE Oman.
A
SPECIFICATION
BURRIED UPPER
MODEL DIAMETER ATTACHMENTS
DEPTH (A) BODY (B)
1 No. 4" Pumper
connection female BSP+
2 No.of Plug Outlet
SFH-100-CIV 1200 mm 669 mm 4” (100mm) 2.5"BS336 Ductile iron
with Ductile Cap inside
builtin ball valve
SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0
KEY FEATURES
• Hydrant Available in 4” and 6” inlet size.
• Working pressure of 16 Bar and test pressure of 25 Bar.
• Flanges conforms to BS4504 Standard (ANSI/DIN Flange Available upon
request)
• Break away design to prevent accidents to the hydrants, where only
the upper part of the flange would be broken upon impact.
• Automatic drain system drains the water in the upper part when the main
valve is closed, thus avoiding damage caused by freezing.
• Hydrant Body (Lower, Middle and Upper body) is of ductile iron. (Cast iron
available up on request)
• Efficient hydraulic design provides optimum performance & maximum flow.
• Easily removable main valve from the ground line flange.
• Hydrants are designed for high performance and easy to
install, maintain and repair. B
SPECIFICATION
BURRIED UPPER
MODEL DIAMETER ATTACHMENTS
DEPTH (A) BODY (B)
A
1 No. of 4” Pumper
*100SFH800-CI 800 mm 600 mm 4” (100mm) Connection & 2 Nos. of
2.5” Dia. Hose Outlet
1 No. of 4” Pumper
*100SFH1200-CI 1200 mm 669 mm 4” (100mm) Connection & 2 Nos. of
2.5” Dia. Hose Outlet
1 No. of 4” Pumper
150SFH800-CI 800 mm 600 mm 6” (150mm) Connection & 2 Nos. of
2.5” Dia. Hose Outlet
1 No. of 4” Pumper
150SFH1200-CI 1200 mm 669 mm 6” (150mm) Connection & 2 Nos. of
SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0
805mm
562.5mm
122.5mm
4 Inch
6 Inch
SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 1 of 3
835mm
682.5mm
1 pc-Adjustable Hydrant Wrench with Electrostatic Powder Paint oven Flashing Light
baked to protect against rust. Torch
1 pc-Pin Lug Spanner Wrench Cabinet is designed to be weather-proof. Certified and Non certified Hoses
Fire Axe All instructions are silk-screened on the are available upon request.
Cabinet & No sticker applied.
4 pcs-2.5” Rubber Gasket for Hose
Other special series or equipment are
Couplings available upon request.
ORDERING
FORM
FIRE HYDRANTS
PARAMETER FIRE HYDRANT SELECTION
QUANTITY
MODEL NUMBER
HYDRANT SIZE 6 INCH 4 INCH 6 INCH 4 INCH 6 INCH 6 INCH 4 INCH 6 INCH
# OUTLET : SIZE “: # OUTLET : SIZE “: # OUTLET : SIZE “: # OUTLET : SIZE “: # OUTLET : SIZE “:
HOSE OUTLET
(NO. & SIZE)
# PUMPER : SIZE “: # PUMPER : SIZE “: # PUMPER : SIZE “: # PUMPER : SIZE “: # PUMPER : SIZE “:
PUMPER OUTLET
(NO. & SIZE)
2.5” OUTLETS 2.5” LANDING VALVE 2.5” MORRIS ADAPTORS WITHOUT VALVES & ADAPTORS STANDARD OTHERS
PRODUCING
SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0
TRUST IN
FIRE AND SAFETY