PRODUCING TRUST IN FIRE AND SAFETY

CERTIFIED
FIRE HYDRANT
SYSTEM
A PRODUCT OF

www.sffecoglobal.com
SFFECO with its more than 30 years of experience
has always been a progressive organization that has
remained in the forefront of the fire fighting industry
with innovative, re-engineered and unique products.

SFFECO in its state-of-the-art manufacturing plants


in RIYADH & DUBAI works in close connections with
renowned governmental and certification bodies to
provide key answers to the challenges faced by the
society.

SFFECO brings together over 3-Decades of


expertise and experience in form of Design,
Consultancy, Testing, Commissioning, Maintenance
& Refurbishment of fire protection and fire
fighting systems.

SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0

SFFECO is proud to be working with International certification


bodies. For specific product certifications, please check the
respective product page or contact our sales team.
SFFECO designs and manufactures multi types of fire hydrants & systems
to be lasting and robust to ensure that they function in all weather
conditions. SFFECO Fire Hydrants are certified by UL, FM and
LPCB. We also manufacture and customize fire hydrants based
on your specific requirements.

DRY BARREL HYDRANT

WET BARREL HYDRANT

ANTI THEFT HYDRANT

SPECIAL APPLICATION HYDRANT

HYDRANT CABINETS

SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0


HYDRANT
DRY BARREL
KEY FEATURES
• UL listed (EX16453) and FM Approved, Conforms to UL 246 and FM 1510 Standard.
• Hydrant Available in 6” inlet size.
• Working pressure of 250Psig and test pressure of 1000 Psig as per UL246 & FM1510.
• Flanges conform to ANSI B16.42 class 150, ANSI B16.1 class 125 & AWWA C11
Mechanical Joint Configuration.
• Break away design to prevent accidents to the hydrants, where only the
upper part of the flange would be broken upon impact.
• Automatic drain system drains the water in the upper part when the main
805
valve is closed, thus avoiding damage caused by freezing.
460
• Hydrant Body (Lower, Middle and Upper body) is of ductile iron.
• Meet all applicable parts of ANSI/AWWA C502 standard.
• Nozzle threads conforms to NFPA 1963 Standard.
• Efficient hydraulic design provides optimum performance & maximum flow.
• Easily removable main valve from either the bonnet or ground line flange.
• Threaded & Field replaceable hose nozzles & pumper outlet
(A)
• Ease of operation by anti-friction washer and forced lubrication.
• Epoxy lined hydrant shoe and nozzle section.
• Hydrant may be supplied with a 3 or 4 in. flanged monitor elbow.
• Hydrants are designed for high performance and easy to install, maintain
and repair.
• Painting: Epoxy/Poly urethene painting with average thickness of 75 microns, RAL3000
(other thickness & fusion bonded expoxy are available upon request).

BURIED BURIED Hose Outlet Pumper Outlet


MODEL DEPTH DEPTH WEIGHT Rated
(mm) (A) (Feet-Inch) (A) Model Certification Pressure
No of Outlet Size No of Outlet Size in PSIG
*SF-F-06 (915) 170 kg Outlets in inches Outlets inches
915 mm 3’ - 0”
4, 4-1/2, 5 NST Pumper
*SF-F-06 (1068) 178 kg SF-F-06 UL/FM 2 2-1/2 1 connection or 5 250
1068 mm 3’ - 6”
nonthreaded Storz

*SF-F-06 (1220) 1220 mm 4’ - 0” 183 kg ***SF-F-06 UL/FM 2 2-1/2 0 — 250

***SF-F-06 UL/FM 4 2-1/2 0 — 250


**SF-F-06 (1372) 1372 mm 4’ - 6” 196 k g
4, 4-1/2, 5 NST
200 k g Pumper connection
**SF-F-06 (1524) 1524 mm 5’ - 0” SF-F-06 UL 2 2-1/2 2
or 5 nonthreaded
250

Storz
**SF-F-06 (1676) 1676 mm 5’ - 6” 210 kg
4, 4-1/2, 5 NST
**SF-F-06 (1829) 1829 mm 6’ - 0” 215 kg Pumper connection
SF-F-06 UL/FM 3 2-1/2 1 250
or 5 nonthreaded
**SF-F-06 (1981) 1981 mm 6’ - 6” 224 kg Storz
SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0

Standard size - 2 number of 2-1/2" hose outlets, 1 Number of 4-1/2" Pumper connection.
* Standard Models ( Subject to stock availability). Other outlet sizes are available upon request only.
** Available upon customer’s request only.
*** Monitor elbow is not available in “FM”

Requirement :
1.All inspection should be according to the factory standard and relate inspection instruction.

{
2.Avoid scratch after assembly the hydrant in order to keep good surface quality. Note : Standard on flange
joint where mechanical
connection is available up
{
on request.
HYDRANT
DRY BARREL
OUTLET CONFIGURATION

Hydrant With 2 Hose


Pumper Outlet : Outlets, 1 Pumper
Hydrant with Flanged Mechanical Joint
Nonthreaded (STORZ) Monitor Elbow (3” or 4”) Flange
Outlet.

Monitor Connection
Available in 3” & 4”

Pumper outlet with


Storz Nozzle (Outer Cap)

Hydrant with 2 hose Hydrant With 2 Hose Hydrant With 3 Hose Hydrant With 4hose
outlets, 0 pumper outlet. Outlets, 2 Pumper Outlet Outlets, 1 Pumper Outlet Outlets, 0 Pumper Outlet

SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0

*Standard size - 2 number of 2-1/2" hose outlets, 1 Number of 4-1/2" Pumper connection. And others are available up
on request only.
HYDRANT
DRY BARREL
KEY FEATURES
• LPCB Approved, Conforms to BS EN 14384: 2005, BS 1074-1, BS 1074-2 & BS 1074-6 Standards.
• Hydrant Available in 4” and 6” inlet size.
• Working pressure of 16 Bar and test pressure of 25 Bar as per BS EN 14384: 2005
• Flanges conforms to EN1092-2 Standard.
• Break away design to prevent accidents to the hydrants, where only the upper part of the flange would be
broken upon impact.
• Automatic drain system drains the water in the upper part when the main valve is closed, thus avoiding
damage caused by freezing.
• Hydrant Body (Lower, Middle and Upper body) is of ductile iron.
• Efficient hydraulic design provides optimum performance & maximum flow.
• Easily removable main valve from the ground line flange.
• Threaded & Field replaceable hose nozzles & pumper outlet
• Available with Different type of caps and outlet landing valves.
• Hydrants are designed for high performance and easy to install, maintain and repair.
• Painting: Inside surface coated with non toxic epoxy paint not less than 300 microns. Outer surface
above ground coated with epoxy paint not less than 300 microns (RAL 3000). Underground portion
coated with asphalt not less than 300 microns (RAL 9005).Other thickness & fusion bonded expoxy are
available upon request).

C GROUND LEVEL
B B
D D

C C GROUND LEVEL HIGHER DEPTH


LOWER DEPTH

HYDRANT
A
HYDRANT

A A

Notes:
1) Available with straight and
90 Deg Horizantal inlet,
with different dimension.
Description Lower Depth Hydrant Details 2) Standard Size For higher depth
hydrant: 2 nos. of 2.5” BSP Description Higher Depth Hydrant Details.
Model SFH100-LPLD SFH150-LPLD hose outlets & 1 no. of 4” BSP
SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0

pumper connection. with


standard depth of 800/1200mm. Model SFH100-LPHD SFH150-LPHD
Size DN100 Flange (4") DN150 Flange (6")
Other options are available
563/713/943 (For Straight inlet) 563/713/943 (For Straight inlet) upon request. Size DN100 Flange (4") DN150 Flange (6")
Buried Depth (mm) (A)
420/575/800 (For 90 Deg inlet) 420/575/800 (For 90 Deg inlet)
3) Standard Size for Lower depth Buried Depth (mm) (A) 800/1200/1445 600/800/1200/1500/1700
Upper body Outlet hydrant: 2 nos. of 2.5” BSP hose
423 423
elevation (B) outlets & 1 no. of 4” BSP pumper Upper body Outlet
Upper body flange connection with standard depth 344 402
of 800mm. Other options are elevation (B)
clearance to ground 58 58
available upon request. Upper body flange
level (mm) ( C )
clearance to ground 53 53
Upper body Pumper 4) Lower Depth hydrants can be level (mm) ( C )
353 353 supplied without the barrel
Oulet elevation (D)
(upper body directly connects
to lower body)
HYDRANT
DRY BARREL
OUTLET CONFIGURATION

HYDRANT WITH LANDING VALVE HYDRANT WITH CAP HYDRANT WITH CAP HYDRANT
WITH LANDING VALVE

LOWER DEPTH HYDRANT DETAIL LOWER DEPTH HYDRANT DETAIL HIGHER DEPTH HYDRANT DETAIL

2.5" Hose outlet Details

Description Reference Standard


Connector,2.5"NH Male Thread, Brass ASME B1.20.7-1991

Cap,2.5"NH Female Thread, Gray Iron/Ductile Iron/Brass ANSI/NFPA 1963-1985


Connector,2.5"BSP Male Thread Aluminum BS21.2779
DN65 Storz Adaptor & Cap Aluminum STORZ 65
DN65 DSP Adaptor With Lock Ring Aluminum
DSP 65
DN65 DSP Adaptor & AP Aluminum
* DN65 Landing Valve Bronze/Brass
BS 336
DN65 Bs Female Adaptor,Aluminum/Brass/Brass Coated Cr

4" Pumper Outlet Details

Description Reference Standard


Connector, 4"NH Male Thread Brass ASME B1.20.7-1991
Cap, 4"NH Female Thread Gray Iron/Ductile Iron ANSI/NFPA 1963-1985
Connector, 4"BSP Male Thread Brass/Aluminum
* Cap, 4"BSP Female Thread Gray Iron BS21.2779
Cap, 4"BSP Male Thread Gray Iron
Connector, 4"BSRT Male Thread,Brass/Brass Plated Cr

Cap, 4"BSRT Female Thread,Ductile Iron/Gray/Gray Iron Plated


SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0

Cr/brass Plated Cr BS336

Connector,4"BSRT Female Thread, Brass


Cap,4"BSRT Male Thread,Ductile Iron/Gray Iron
DN100 Storz Adaptor & Cap, Aluminum Storz 100
DN100 Dsp Adaptor With Lock Ring, Aluminum
DSP 100
DN100 Dsp Adaptor & Cap , Aluminum

* Standard outlet types.


Other outlet details are optional and can be supplied at customer request.
HYDRANT
WET BARREL Working Pressure
KEY FEATURES 250PSI for UL/FM Listed
• UL listed (EX16453) and FM Approved, Conforms to UL 246 and FM 1511 Standard.
• Hydrant Available in 6” inlet size.
• Working pressure of 250Psig and test pressure of 1000 Psig as per UL246 & FM1511.
• Flanges conforms to ANSI B16.42 class 150 and ANSI B16.1 class 125
• Hydrant Body is of ductile iron.
• Meet all applicable parts of ANSI/AWWA C503 standard.
• Nozzle threads conforms to NFPA 1963 Standard.
• Efficient hydraulic design provides optimum performance & maximum flow.
• Hydrants are designed for high performance and easy to install, maintain and repair.
• Threaded & Field replaceable hose nozzles & pumper outlet
• Hydrant may be supplied with a 3” (UL) or 4” (UL/FM) size monitor flange on top of the hydrant.
• Painting: Interior and exterior is e-coated to a dry film thickness of 0.6 mils minimum, then fusion
bonded epoxy powder coated ( FBE) (Other thickness are available upon request).

MODEL MODEL

SFD-250-WH SFD-250-WH
Flanged Head Closed Head

Ø229
All Dimensions are measured in MM

95
135

663
720

360

Ø279
Ø279

Hose Outlet Pumper Outlet

Model Certification Outlet Rated


No of No of Outlet Size in
Size in Pressure,
Outlets Outlets inches
inches PSIG

SFD-250-WH UL/FM 2 2-1/2 - - 250


SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0

4 NST Pumper
SFD-250-WH UL/FM 1 2-1/2 1 250
Connection

4, 4-1/2 NST Pumper


SFD-250-WH UL/FM 2 2-1/2 1 connection or 5 250
Non threaded storz

4-1/2 NST Pumper


SFD-250-WH UL 1 2-1/2 1 connection or 5 250
Non threaded storz

Standard size - 2 number of 2-2/1 " hose outlets, 1 Number of 4-1/2" Pumper connection.
Other optionals are available upon request.
HYDRANT
WET BARREL
OUTLET CONFIGURATION

Hydrant With 1 Hose Hydrant with 2 hose


Hydrant With 1 Hose Outlets, 1 Pumper Outlet, outlets
Outlets, 1 Pumper Outlet With Monitor Flange

Hydrant With 2 Hose Hydrant With 2 Hose


Hydrant With 2 Hose Outlets, 1 Pumper Outlet
Outlets, 1 Pumper Outlet,
Outlets, 1 Pumper Outlet Storz (Non Threaded)
With Monitor Flange

SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0


HYDRANT
DRY BARREL
ANTI THEFT HYDRANT
All Dimensions are measured in MM

KEY FEATURES
• New Developed with built-in ball valve and standard straight valve.
• Hydrant Available in 4” and 6” inlet size.
• Working pressure of 16 Bar and test pressure of 25 Bar.
• Flanges conforms to BS4504 Standard (ANSI/DIN Flange Available upon request)
• Break away design to prevent accidents to the hydrants, where only the upper
part of the flange would be broken upon impact.
• Automatic drain system drains the water in the upper part when the main valve is
closed, thus avoiding damage caused by freezing.
• Hydrant Body (Lower, Middle and Upper body) is of ductile iron. (Cast iron
available up on request)
• Efficient hydraulic design provides optimum performance
& maximum flow.
B
• Easily removable main valve from the ground line flange.
• Hydrants are designed for high performance and easy to
install, maintain and repair.
• Painting: Buried part surface with RAL 9005 black paint,
GROUND LEVEL
outside surface with RAL 3000 Paint.
• Approved by Royal Oman Police & PAWE Oman.

A
SPECIFICATION
BURRIED UPPER
MODEL DIAMETER ATTACHMENTS
DEPTH (A) BODY (B)
1 No. 4" Pumper
connection female BSP+
2 No.of Plug Outlet
SFH-100-CIV 1200 mm 669 mm 4” (100mm) 2.5"BS336 Ductile iron
with Ductile Cap inside
builtin ball valve
SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0

1 No. 4" Pumper


connection female BSP+
2 No.of Plug Outlet
SFH-150-CIV 1200 mm 669 mm 6” (150mm) 2.5"BS336 Ductile iron
with Ductile Cap inside
builtin ball valve

Other depths are available upon customer’s request.


HYDRANT
DRY BARREL
SPECIAL APPLICATION HYDRANT
All Dimensions are measured in MM

KEY FEATURES
• Hydrant Available in 4” and 6” inlet size.
• Working pressure of 16 Bar and test pressure of 25 Bar.
• Flanges conforms to BS4504 Standard (ANSI/DIN Flange Available upon
request)
• Break away design to prevent accidents to the hydrants, where only
the upper part of the flange would be broken upon impact.
• Automatic drain system drains the water in the upper part when the main
valve is closed, thus avoiding damage caused by freezing.
• Hydrant Body (Lower, Middle and Upper body) is of ductile iron. (Cast iron
available up on request)
• Efficient hydraulic design provides optimum performance & maximum flow.
• Easily removable main valve from the ground line flange.
• Hydrants are designed for high performance and easy to
install, maintain and repair. B

• Painting: Buried part surface with RAL 9005 black paint,


outside surface with RAL 3000 Paint.
GROUND LEVEL

SPECIFICATION
BURRIED UPPER
MODEL DIAMETER ATTACHMENTS
DEPTH (A) BODY (B)
A
1 No. of 4” Pumper
*100SFH800-CI 800 mm 600 mm 4” (100mm) Connection & 2 Nos. of
2.5” Dia. Hose Outlet

1 No. of 4” Pumper
*100SFH1200-CI 1200 mm 669 mm 4” (100mm) Connection & 2 Nos. of
2.5” Dia. Hose Outlet

1 No. of 4” Pumper
150SFH800-CI 800 mm 600 mm 6” (150mm) Connection & 2 Nos. of
2.5” Dia. Hose Outlet
1 No. of 4” Pumper
150SFH1200-CI 1200 mm 669 mm 6” (150mm) Connection & 2 Nos. of
SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0

2.5” Dia. Hose Outlet

Other depths are available upon customer’s request.


HYDRANT
WET BARREL
SPECIAL APPLICATION HYDRANT
MODELS
KEY FEATURES SFH – 50W/100 – 4”
• Hydrant Available in 4” and 6” inlet size. SFH – 50W/150 – 6”
• Working pressure of 16 Bar and test pressure of 25 Bar.
• Flanges conforms to BS4504 Standard (ANSI/DIN Flange Available upon request)
• Hydrant Body is of Cast Iron.
• Ductile hydrants available upon request.
• Two numbers of 2½" hydrant landing valves with cap and chain are provided with hydrants.
• The valves are of BSPT threads inlets and PN16 rating.
• Other pressure ratings are available upon request.
• Efficient hydraulic design provides optimum performance & maximum flow.
• Hydrants are designed for high performance and easy to install, maintain and repair.
• Painting: Color RED RAL 3000.

805mm

562.5mm

122.5mm

4 Inch
6 Inch
SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 1 of 3

835mm

682.5mm

{ Wet fire hydrant is used in places where no


danger of Vehicle accidents or freezing
{
atmospheres. It is better to be used in malls,
shopping centers, colleges, hospitals, etc.
HYDRANT
CABINETS
SHC-800
Length Width Depth Leg Height
SHC-750 1500mm 800mm 250mm 100mm

Length Width Depth Leg Height


1000mm 800mm 250mm 600mm

Standard Accessories Cabinet Design Optional Accessories


2 pcs-Fire Hose Size 2.5”x100 feet Cabinet doors are made from 1mm Extra Fire hose 2.5” or
synthetic rubber lined with Aluminum mild steel or stainless steel. 1.5”. Double jacket Hoses.
& morris coupling. Availablein brushed, hairline or mirror Crow Bar
finish (SS304 or SS316 Grade).
2 pcs-Hose Nozzle 2.5 morris coupling. 2.5” Underwriters Play Pipe
Corrosion Protection-cabinets are painted
SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0

1 pc-Adjustable Hydrant Wrench with Electrostatic Powder Paint oven Flashing Light
baked to protect against rust. Torch
1 pc-Pin Lug Spanner Wrench Cabinet is designed to be weather-proof. Certified and Non certified Hoses
Fire Axe All instructions are silk-screened on the are available upon request.
Cabinet & No sticker applied.
4 pcs-2.5” Rubber Gasket for Hose
Other special series or equipment are
Couplings available upon request.
ORDERING
FORM
FIRE HYDRANTS
PARAMETER FIRE HYDRANT SELECTION
QUANTITY

MODEL NUMBER

TYPE WET DRY


APPROVAL UL FM UL-FM STANDARD LPCB UL FM UL-FM STANDARD

HYDRANT SIZE 6 INCH 4 INCH 6 INCH 4 INCH 6 INCH 6 INCH 4 INCH 6 INCH

800mm 1200mm 915mm 1220mm 800mm 1200mm


BURRIED DEPTH NOT APPLICABLE NOT APPLICABLE OTHERS, SPECIFY OTHERS, SPECIFY OTHERS, SPECIFY

# OUTLET : SIZE “: # OUTLET : SIZE “: # OUTLET : SIZE “: # OUTLET : SIZE “: # OUTLET : SIZE “:
HOSE OUTLET
(NO. & SIZE)

# PUMPER : SIZE “: # PUMPER : SIZE “: # PUMPER : SIZE “: # PUMPER : SIZE “: # PUMPER : SIZE “:
PUMPER OUTLET
(NO. & SIZE)

WITH MONITOR YES NO YES NO


FLANGE IF YES, PLEASE SPECIFY NO NOT APPLICABLE YES NO
IF YES, PLEASE SPECIFY
3” 4” 3” 4”

2.5” OUTLETS 2.5” LANDING VALVE 2.5” MORRIS ADAPTORS WITHOUT VALVES & ADAPTORS STANDARD OTHERS

STRAIGHT OR 90 NOT APPLICABLE NOT APPLICABLE


INLET FLANGE 90 INLET STRAIGHT 90 INLET

OTHER SPECIAL REQUIREMENTS : SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0


A PRODUCT OF

PRODUCING
SFG-HYDCAT | Date 30/12/2018 | Rev. No.: 0.0

TRUST IN
FIRE AND SAFETY

You might also like