6777317e8bf6eb3dbdf43f4a 70255451274
6777317e8bf6eb3dbdf43f4a 70255451274
Godwin cd150 parts breakdown. Godwin cd150 parts manual. Godwin cd150 pump parts breakdown. Godwin pump cd150 manual.
Manual for CD, HL & NC Range Dri-Prime Pumps 95-0019-0000 Edition. Installation, operation, and maintenance guidelines. The equipment's warranty is void if parts not approved by Godwin Pumps Ltd are used. Parts must meet correct material, dimensions, or finish standards. Failure to comply will invalidate the warranty. Pumps' warranty policy
applies unless special arrangements are made in writing by both parties. Damages arising from improper use of unapproved parts or failure to follow instructions will not be covered. The equipment must be lifted safely according to local and national guidelines. Figure 1-4 illustrate safe lifting practices, but consult Godwin Pumps Ltd if unsure.
Personnel working on the pump must wear clean, fitting clothing and safety footwear. Clothing impregnated with oil or fuel can cause health hazards through prolonged skin contact and may also pose a fire hazard. The equipment's serial number must be quoted in any inquiry for spares or service. Genuine parts from local Godwin Pumps Ltd
suppliers are recommended to maintain warranty validity. Failure to do so may reduce the pump's working life. Pumps in this range should only operate in one direction. Alignment adjustments should be made by moving the driver, not the pump. The installer is responsible for providing an additional 0.25mm (0.010”) height difference between pump
and driver support for shimming purposes. When cold weather is imminent and frost is possible, drain the pump and non-return valve (if fitted) by removing the drain plug located on the bottom or side of the volute or discharge flange. For bearings, check every 250 hours and re-grease if necessary. Mechanical seals cooled by oil or glycol should have
their coolant levels checked at least weekly. To remove a seal, follow procedure 8.3.1 for pumps CD75 to CD100M, and procedure 8.4.1 for other pumps. For seal removal, isolate the driver, ensure the pump is not operational, drain the delivery line, and lock the pump shaft to prevent rotation. Then, follow procedures 8.3.2 or 8.4.1 depending on the
pump type. For rear wear plate removal, undo fasteners from the motor adaptor/bearing bracket/seal housing adaptor side. Cleanliness is crucial throughout the entire installation process. Never touch or allow contaminants to come into contact with these components. Page 21: Set the initial seal working length, apply thread locking compound (refer
to Technical Data), and lightly tighten the drive screws to centralize and secure the sleeve on the shaft. A special tool from Godwin Pumps Ltd is available for correct seal setting. Page 22: Installation, Operation, and Maintenance Manual CD, HL & NC Ranges of Dri-Prime Pumps Fit a new roll pin into the wear plate, carefully tapping it in from the
impeller side until flush with that side. It should protrude 2-3mm from the seal side. Installation, Operation, and Maintenance Manual CD, HL & NC Ranges of Dri-Prime Pumps 8.5.3 Fitting the wear plate Pump types CD75/ CD80D/ CD80M/ CD100M/ CD103M/ CD150M HL80 NC80/ NC100/ NC150 Smear the outside diameters and O-rings with oil to
aid assembly, helping prevent rust and facilitating future strip-downs. This article cannot be generated as it has been marked as 'spam' Pumps and their components require proper installation, operation, and maintenance to ensure efficient and safe functioning. The following instructions are for pumps in the CD, HL, and NC ranges: ####CD Range
BearinGs** * Heat bearings: Single roller bearing inner race (pump end) and complete spherical roller bearing (drive end) + For CD140M, CD225, CD250M, HL100M, HL110M, HL125MS, and HL150M * Heat single roller bearing inner race and two angular contact bearings ####HL Range BearinGs** * Heat bearings: Single roller bearing inner
race (pump end) and complete spherical roller bearing (drive end) + For HL130M/HL160M/HL225M/HL250M/HL260M * Once up to temperature, take the two angular contact bearings and slide them up hard against the shaft shoulder at the drive end ####Air Compressor** * Fitted with an air compressor for smaller pumps in the range + Follow
instructions for filter replacement and pipe work checking ####Link Belt Tensioning** * Check and adjust weekly or after every 100 hours of operation + Use adjusting studs and clamping screws (Figure 29) ####Tools** * Pump MA version: CD75, CD80D, CD80M, CD100M, CD103M, CD140M, CD150M * Special tools: + First seal setting tool for
HL110M/HL200M + Shaft aligning jig (CD300M) ####Technical Data** * Designations, sizes, and capacities for CD and HL ranges Installation, Operation and Maintenance Manual for Dri-Prime Pumps CD, HL & NC Ranges - Iss 11. This manual outlines the specifications for various models within the HL and NC ranges of Dri-Prime pumps. Key
information includes: ####HL Range Data: The HL range consists of pumps with capacities ranging from HL260M to HL80. ####NC Range Data: Similarly, the NC range encompasses pumps such as NC150, NC100, and NC80. ####Spanner Torques: Recommended tightening torques for general-purpose fasteners are provided in this section.
These values should be used when joining metal components without gaskets or specialized fixtures. ####Belt Tensioning (Force & Deflection Method): A specific method for achieving belt tension involves applying a setting force at the midpoint of the belt to achieve a desired deflection, thus ensuring proper belt alignment. Contact information for
Godwin Pumps in England and America is also included.