AL MOGHAMMAS RESERVIOR

TRANSMISSION SYSTEM PACKAGE-C

TABLE OF CONTENT

DESCRIPTIONS
SR NO YES REMARKS

01.0 Reply reference no. EF-AMF-L-0646 ✓


01.1 AMA ✓
02.1 Lifetime Warranty ✓
03.1 Master Keying Schedule ✓
04.1 One Year Warranty ✓
05.1 Stainless care ✓
06.1 Three-year warranty ✓
07.1 Warranty Period ✓
08.1 UL and Test Certificate ✓
AL-MOGHAMMAS RESERVIOR
TRANSMISSION SYSTEM Package-C.

02.0 Lifetime Warranty


139 Victor Street
St. Louis, Missouri 63104
800-255-3590 main
314-772-4400 main
314-772-0744 fax
www.hagerco.com

LIFETIME WARRANTY

*Locks (exceptions: 2300 Series, 2500 Series and 3600 Series), Closers (exceptions: 5400 Series), Exit Devices
(exceptions: 4700 Series), Roton (exceptions: Electric), Stainless Steel Continuous Hinges (exceptions: Electric),
Architectural Hinges including 3-Knuckle (exceptions: Electric, ECCO, Spring Hinges and 2-Knuckle Hinges).

Subject to the limitations of liability set forth below, Hager Companies (the “Company”) warrants to purchasers that the
products which the Company sells under the Hager name are free from defects in workmanship and materials under normal
use and regular service and maintenance for a period of the useful life of the building in which originally installed.

THIS IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCTS AND IS IN
LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, ARISING BY OPERATION OF LAW OR OTHERWISE, ALL
IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, NONINFRINGEMENT,
AND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY EXCLUDED.

This warranty does not cover defects or damage arising from improper installation, incorrect application, lack of or improper
maintenance, improper storage, shipping and handling, ordinary wear and tear, misuse, abuse, accident, unauthorized
service, or use with unauthorized products or parts.

The sole and exclusive liability of the Company under this warranty or otherwise, shall be limited to the repair or replacement
of any product or component part which shall prove defective to the original purchaser from the Company. The Company, as
covered in these limited warranties, will not cover the costs for the removal and reinstallation of products, shipping and freight
expenses required to return the product, or any other related incidental, or indirect punitive damages. THE COMPANY SHALL
NOT BE LIABLE FOR DAMAGES CAUSED BY DELAY IN PERFORMANCE AND IN NO EVENT, REGARDLESS OF THE FORM OF
THE CLAIM OR CAUSE OF ACTION (WHETHER BASED ON CONTRACT, INFRINGEMENT, NEGLIGENCE, STRICT LIABILITY,
OTHER TORT OR OTHERWISE), SHALL THE COMPANY’S LIABILITY TO PURCHASER AND/OR ITS CUSTOMERS EXCEED THE
PRICE PAID BY PURCHASER FOR THE SPECIFIC PRODUCTS PROVIDED BY THE COMPANY GIVING RISE TO THE CLAIM OR
CAUSE OF ACTION. PURCHASER AGREES THAT IN NO EVENT SHALL THE COMPANY’S LIABILITY TO PURCHASER AND/OR
ITS CUSTOMERS EXTEND TO INCLUDE INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES RESULTING FROM USE
OF THESE PRODUCTS, OR ARISING OUT OF ANY BREACH OF THIS WARRANTY. The term “consequential damages” shall
include, but not be limited to, loss of anticipated profits, business interruption, loss of use or revenue, cost of capital or loss
or damage to property or equipment. The foregoing limitations and exclusions are intended to be effective to the maximum
extent permitted by law. This warranty is governed by the law of the State of Missouri without regard to its conflicts of law
principles. The company and purchaser agree that the United Nations Convention on Contracts for the International Sale of
Goods and the United Nations Convention on the Limitation Period in the International Sale of Goods shall not apply to sales
of the products covered by this warranty.

Written notice of a product believed to be defective as covered by this warranty should be emailed to Hager Companies,
at [email protected] within 30 days from the discovery of the alleged defects, and should include the
purchaser’s name and address, identification of the product, and brief description of the defect. Upon receipt of such
notice, the Company will inform the purchaser where to ship such product, shipping charges prepaid, for examination. In
the event such examination reveals a defect covered by this warranty, the Company will, at its own option, repair or
replace the product, and return it or the replacement to the purchaser, with charge only for transportation.

One Family. One Brand. One Vision.TM


AL-MOGHAMMAS RESERVIOR
TRANSMISSION SYSTEM Package-C.

03.0 Master Keying Schedule


Al Moghammas Strategic

GMK‐A

MK-AA MK-AB MK-AC

SAFETY & SECURITY WORKSHOP BUILDING


ELECTRICAL BUILDING
BUILDING &-1ST FLOOR)

Change Key Change Key Change Key


AA1 AB1 AC1 ‐ AC9
PROPOSED MASTER KEYING SCHEDULE
Project :‐ Al Moghammas Strategic

KEYING INFORMATION Contract#:‐ HW0028241‐KM‐16EU‐Metal Doors


a. GMK : 5 Keys. Date:‐ 25‐11‐2024
b. MK : 5 Keys for each group (5 x 3 = 15)
c. CK : 3 Keys for each cylinder (11 x 3 = 33)

SPECIFIED OPERATION
a. GMK‐A will Operate all Cylinders in the buildings
b. MK‐AA, AB & AC will operate all locks in specified group in each building
c. Change key is a independent key operating its own specified location

Change
Head# Building / Area Door / Frame Door Type Location 1 Description Lock Cyl/ IC Core QTY GMK MK Remarks
Key
003 AL‐MOGHAMMAS (ELECTRICAL BUILDING) HMD X HMF D5A Low voltage Intrumentation Cabinet Outside Trim Exit Device 42CE x WLM lever 3000‐45H x 45mm 1 A AA AA1 HW0028241

008 SAFETY & SECURITY BUILDING HMD X HMF D3 HVAC ROOM Outside Trim Exit Device 42CE x WLM lever 3000‐45H x 45mm 1 A AB AB1 HW0028241

016 WORKSHOP BUILDING HMD X HMF D6 WORKSHOP Outside Trim Exit Device 42CE x WLM lever 3000‐45H x 45mm 1 A AC AC1 HW0028241
016 WORKSHOP BUILDING HMD X HMF D6 WORKSHOP Outside Trim Exit Device 42CE x WLM lever 3000‐45H x 45mm 1 A AC AC2 HW0028241
016 WORKSHOP BUILDING HMD X HMF D6 WORKSHOP Outside Trim Exit Device 42CE x WLM lever 3000‐45H x 45mm 1 A AC AC3 HW0028241
016 WORKSHOP BUILDING HMD X HMF D6 WORKSHOP Outside Trim Exit Device 42CE x WLM lever 3000‐45H x 45mm 1 A AC AC4 HW0028241
018 WORKSHOP BUILDING HMD X HMF D8B STORAGE TOOLS Mortise Sashlock 3800U‐55S x 55BS 3000‐70D x 70mm 1 A AC AC5 HW0028241
024 WORKSHOP BUILDING HMD X HMF D10A INSTALLATION SHAFTS Outside Trim Exit Device 42CE x WLM lever 3000‐45H x 45mm 1 A AC AC6 HW0028241
024 WORKSHOP BUILDING HMD X HMF D10A INSTALLATION SHAFTS Outside Trim Exit Device 42CE x WLM lever 3000‐45H x 45mm 1 A AC AC7 HW0028241
026 WORKSHOP BUILDING‐1ST FLOOR HMD X HMF D4A CORRIDOR Outside Trim Exit Device 42CE x WLM lever 3000‐45H x 45mm 1 A AC AC8 HW0028241
026 WORKSHOP BUILDING‐1ST FLOOR HMD X HMF D4A CORRIDOR Outside Trim Exit Device 42CE x WLM lever 3000‐45H x 45mm 1 A AC AC9 HW0028241
031 WORKSHOP BUILDING‐1ST FLOOR WD X HMF D14 TOILET Mortise Bathroom Lock 3800U‐55B x 55BS NO CYLINDER HW0029311
031 WORKSHOP BUILDING‐1ST FLOOR WD X HMF D14 TOILET Mortise Bathroom Lock 3800U‐55B x 55BS NO CYLINDER HW0029311
031 WORKSHOP BUILDING‐1ST FLOOR WD X HMF D14 TOILET Mortise Bathroom Lock 3800U‐55B x 55BS NO CYLINDER HW0029311
031 WORKSHOP BUILDING‐1ST FLOOR WD X HMF D14 TOILET Mortise Bathroom Lock 3800U‐55B x 55BS NO CYLINDER HW0029311
Total 11
AL-MOGHAMMAS RESERVIOR
TRANSMISSION SYSTEM Package-C.

04.0 One Year Warranty


139 Victor Street
St. Louis, Missouri 63104
800-255-3590 main
314-772-4400 main
314-772-0744 fax
www.hagerco.com

ONE-YEAR WARRANTY

*Electrified Products including 8 200 Series Auto Operators, Sliding D oor Hardware, Trim a nd Auxiliary, Electric
Modifications on Locks and Exit Devices, ECCO Hinges, Pivots, Residential Hinges, Electric Architectural Hinges, Spring
Hinges, 2-Knuckle Hinges, Air Transfer Hinges, Roton Electric Hinges, and Electric Stainless Steel Hinges.

Subject to the limitations of liability set forth below, Hager Companies (the “Company”) warrants to purchasers that the
products identified above which the Company sells under the “Hager” trademark or trade name are free from defects in
workmanship and materials under normal use and regular service and maintenance for a period of one year from date of
delivery.*

THIS IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCTS AND IS IN
LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, ARISING BY OPERATION OF LAW OR OTHERWISE. ALL
IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, NON-INFRINGEMENT
AND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY EXCLUDED.

This warranty does not cover defects or damage arising from improper installation, incorrect application, lack of or improper
maintenance, improper storage, shipping and handling, excessive wear and tear, misuse, abuse, accident, unauthorized
service, or use with unauthorized products or parts.

The sole and exclusive liability of the Company under this warranty or otherwise, shall be limited to the repair or
replacement of any product or component part which shall prove defective to the original purchaser from the Company. The
Company, as covered in these limited warranties, will not cover the costs for the removal and reinstallation of products,
shipping and freight expenses required to return the product, or any other related incidental, or indirect punitive
damages. THE COMPANY SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY DELAY IN PERFORMANCE AND IN NO EVENT,
REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTION (WHETHER BASED ON CONTRACT, INFRINGEMENT,
NEGLIGENCE, STRICT LIABILITY, OTHER TORT OR OTHERWISE), SHALL THE COMPANY’S LIABILITY TO PURCHASER
AND/OR ITS CUSTOMERS EXCEED THE PRICE PAID BY PURCHASER FOR THE SPECIFIC PRODUCTS GIVING RISE TO THE
CLAIM OR CAUSE OF ACTION. PURCHASER AGREES THAT IN NO EVENT SHALL THE COMPANY’S LIABILITY TO
PURCHASER AND/OR ITS CUSTOMERS EXTEND TO INCLUDE INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES
RESULTING FROM USE OF THESE PRODUCTS, OR ARISING OUT OF ANY BREACH OF THIS WARRANTY. The term
“consequential damages” shall include, but not limited to, loss of anticipated profits, business interruption, loss of use or
revenue, cost of capital or loss or damage to property or equipment. The foregoing limitations and exclusions are intended
to be effective to the maximum extent permitted by law. This warranty is governed by the law of the State of Missouri
without regard to its conflicts of law principles. The company and purchaser agree that the United Nations Convention on
Contracts for the International Sale of Goods and the United Nations Convention on the Limitation Period in the
International Sale of Goods shall not apply to sales of the products covered by this warranty.

Written notice of a product believed to be defective as covered by this warranty should be emailed to Hager Companies, at
[email protected] within 30 days from the discovery of the alleged defects, and should include the purchaser’s
name and address, identification of the product, and brief description of the defect. Upon receipt of such notice, the
Company will inform the purchaser where to ship such product, shipping charges prepaid, for examination. In the event
such examination reveals a defect covered by this warranty, the Company will, at its own option, repair or replace the
product, and return it or the replacement to the purchaser, with charge only for transportation.

One Family. One Brand. One Vision.TM


AL-MOGHAMMAS RESERVIOR
TRANSMISSION SYSTEM Package-C.

05.0 Stainless care


139 Victor Street
St. Louis, Missouri 63104
800-255-3590 main
314-772-4400 main
314-772-0744 fax
www.hagerco.com

STAINLESS STEEL HARDWARE CARE AND CLEANING

What Makes Stainless Steel “Stainless”?


Stainless steel differs from carbon steel by the amount of chromium present. Unprotected carbon steel rusts readily when exposed to air
and moisture. This iron oxide film (the rust) is active and accelerates corrosion by forming more iron oxide. The corrosion will continue
until all the carbon steel is converted into iron oxide.

Stainless steel is a group of alloys that contain a minimum of 10.5% chromium. Because stainless steel contains at least 10.5% chromium,
the oxidation of the iron is changed to produce a complex oxide that resists further oxidation and forms a passive layer on the surface.
The passive layer is only a few microns in thickness and will reform if it is removed by scratching or machining. If stainless steel is
properly selected and maintained, it should not suffer any corrosion. For highly corrosive areas, 316 grade or clear coat over 304L may be
recommended. Hager’s standard grade stainless steel is 304L.

What Makes Stainless Steel Corrode?


Stainless steel is corrosion resistant not corrosion proof and will corrode under certain conditions. Corrosion in stainless steel is not the
same type of corrosion as found in carbon steel. The most likely form of stainless steel corrosion is “pitting”. Pitting occurs when the
environment overpowers the ability of stainless steel to reform the passive layer. Normally dark brown pits occur on the surface of the
stainless steel.

The three key types of corrosion that normally effect door hardware products are:
1. Atmospheric Corrosion
Atmospheric corrosion occurs when stainless steel is exposed to airborne liquids, solids or gases. Some sources of
atmospheric corrosion are sea spray, rain in coastal zones, salt (possibly from de-icing), and dirt. This form of corrosion is
typically worse outdoors, especially near marine environments.
2. Chemical Corrosion
Chemical corrosion takes place when stainless steel comes in direct contact with a material that has a high chloride
concentration or a strong corrosive solution. Some factors which affect the severity of chemical corrosion include:
chemical/chloride concentration level, duration of contact, frequency of washing, and the operating environment.
3. Contact Corrosion
A small piece of carbon steel, scale, copper, or foreign material lodged in stainless steel may be sufficient to destroy
passivity at the point of contact and cause pitting. Carbon steel brushes and steel wool should never be used to
clean stainless steel.

Maintenance of Stainless Steel Finishes


Cleanliness is essential for maximum resistance to corrosion. Surface contamination by dirt or other materials hinders the ability of stainless
steel to reform the passive layer and traps corrosive agents, reducing corrosion protection.

In many cases, standard household cleaners can be used to clean and maintain stainless steel hardware items. Soap, ammonia, and
detergent and water are used to clean normal dirt. Cleaning should always be followed by rinsing with clean water. When water contains
mineral solids, which leave water spots, it is advisable to wipe the surface completely with dry towels.

In selecting cleaning practices, consider the possibility of scratching and the potential for post cleaning corosion caused by incompletely
removed cleaners. Select only cleaners that are not abrasive, not acidic, and low in chloride. Many antibacterial cleaners used to clean and
sanitize door hardware contain high levels of chlorides, which will cause corrosion if not properly removed from the surface by rinsing.

Routine cleaning is essential, especially in environments that have elevated levels of atmospheric corrosion. Proper care for your stainless
steel door hardware will result in many years of durable use.

Acknowledgements:
Stainless Steel Industry of North America
Euro Inox - European Stainless Steel Development Association

One Family. One Brand. One Vision.TM


AL-MOGHAMMAS RESERVIOR
TRANSMISSION SYSTEM Package-C.

06.0 Three-year warranty


139 Victor Street
St. Louis, Missouri 63104
800-255-3590 main
314-772-4400 main
314-772-0744 fax
www.hagerco.com

THREE-YEAR WARRANTY

*All Euroline products including Mortise Lock Bodies, Levers, Cylinders, Door Controls, Patch Fittings and Architectural Hinges.

Subject to the limitations of liability set forth below, Hager Companies (the “Company”) warrants to purchasers that the
products identified above which the Company sells under the “Hager” trademark or trade name are free from defects in
workmanship and materials under normal use and regular service and maintenance for a period of five years from date of
delivery.*

THIS IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCTS AND IS IN
LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, ARISING BY OPERATION OF LAW OR OTHERWISE. ALL
IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, NON-INFRINGEMENT
AND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY EXCLUDED.

This warranty does not cover defects or damage arising from improper installation, incorrect application, lack of or improper
maintenance, improper storage, shipping and handling, excessive wear and tear, misuse, abuse, accident, unauthorized
service, or use with unauthorized products or parts.

The sole and exclusive liability of the Company under this warranty or otherwise, shall be limited to the repair or replacement
of any product or component part which shall prove defective to the original purchaser from the Company. The Company,
as covered in these limited warranties, will not cover the costs for the removal and reinstallation of products, shipping
and freight expenses required to return the product, or any other related incidental, or indirect punitive damages. THE
COMPANY SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY DELAY IN PERFORMANCE AND IN NO EVENT, REGARDLESS
OF THE FORM OF THE CLAIM OR CAUSE OF ACTION (WHETHER BASED ON CONTRACT, INFRINGEMENT, NEGLIGENCE,
STRICT LIABILITY, OTHER TORT OR OTHERWISE), SHALL THE COMPANY’S LIABILITY TO PURCHASER AND/OR ITS
CUSTOMERS EXCEED THE PRICE PAID BY PURCHASER FOR THE SPECIFIC PRODUCTS GIVING RISE TO THE CLAIM OR
CAUSE OF ACTION. PURCHASER AGREES THAT IN NO EVENT SHALL THE COMPANY’S LIABILITY TO PURCHASER AND/OR
ITS CUSTOMERS EXTEND TO INCLUDE INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES RESULTING FROM USE
OF THESE PRODUCTS, OR ARISING OUT OF ANY BREACH OF THIS WARRANTY. The term “consequential damages” shall
include, but not limited to, loss of anticipated profits, business interruption, loss of use or revenue, cost of capital or loss or
damage to property or equipment. The foregoing limitations and exclusions are intended to be effective to the maximum
extent permitted by law. This warranty is governed by the law of the State of Missouri without regard to its conflicts of law
principles. The company and purchaser agree that the United Nations Convention on Contracts for the International Sale of
Goods and the United Nations Convention on the Limitation Period in the International Sale of Goods shall not apply to sales
of the products covered by this warranty.

Written notice of a product believed to be defective as covered by this warranty should be sent to Hager Companies, 139
Victor Street, St. Louis, Missouri 63104 within 30 days from the discovery of the alleged defects, and should include the
purchaser’s name and address, identification of the product, and brief description of the defect. Upon receipt of such notice,
the Company will inform the purchaser where to ship such product, shipping charges prepaid, for examination. In the event
such examination reveals a defect covered by this warranty, the Company will, at its own option, repair or replace the
product, and return it or the replacement to the purchaser, with charge only for transportation.

One Family. One Brand. One Vision.TM


AL-MOGHAMMAS RESERVIOR
TRANSMISSION SYSTEM Package-C.

07.0 Warranty Period


AL-MOGHAMMAS RESERVIOR
TRANSMISSION SYSTEM Package-C.

08.0 UL and Test Certificate


CERTIFICATE OF APPROVAL
No CF 5908
This is to certify that, in accordance with
TS00 General Requirements for Certification of Fire Protection Products
The undermentioned products of
1

HAGER COMPANIES
139 Victor Street, St. Louis MO 63124
Tel: (314) 772-4400

Have been assessed against the requirements of the Technical Schedule(s)


denoted below and are approved for use subject to the conditions
appended hereto:
_____________________________________________________________________________________________________

CERTIFIED PRODUCT TECHNICAL SCHEDULE


3800U SERIES LOCKS TS23 The Contribution of
Locks and Latches to The
Performance of Fire Resisting
Doorsets

TS 31 The Contribution Of
Emergency Exit Devices,
Operated By A Lever Handle Or
Push Pad, To The Performance
Of Fire Resisting Door
Assemblies

Signed and sealed for and on behalf of Warringtonfire Testing and Certification Limited

Paul Duggan
Certification Manager Issued: 6th August 2021
Reissued: 30th April 2024
Valid to: 5th August 2026

Page 1 of 8

This certificate is the property of Warringtonfire Testing and Certification Limited


Registered in England and Wales
Registered Office: 3rd Floor, Davidson Building, 5 Southampton Street, London, WC2E 7HA. Company Registration No: 11371436
CERTIFICATE No CF 5908
HAGER COMPANIES
3800U SERIES LOCKS

1. The locks and latches covered by this certificate are all steel cased. This approval relates
to the following specific locks:

Reference Description
3800U-55S Sashlock
3800U-55F Deadlock
3800U-55B Bathroom Lock
3800U-55L Plain Latch
3800U-55M Nightlatch
3800U-55T Nightlatch w/ Anti-thrust bolt
3800U-55P Anti-Panic Mortise Lock

The mortice locks have a maximum 235 mm high x 24 mm wide forend; the latch/deadbolt,
case, forend and strikeplates are all of steel, with a latchbolt projection of 12.5 mm. All
models approved in 55mm backset, with 20 mm and 24 mm width forend options and either
square or radiused forend and strikeplate.

2. This certification is provided to the client for their own purposes and we cannot opine on
whether it will be accepted by Building Control authorities or any other third parties for any
purpose.

3. This approval relates to their use with the following door assemblies:-

Latched and unlatched, intumescent sealed door assemblies consisting of timber


faced and edged leaves with timber, cellulosic or mineral cores in timber frames
having a fire resistance up to 60 minutes (Code ITT).

Latched and unlatched, door assemblies consisting of uninsulated or insulated


predominantly steel leaves, hung in steel frames with or without intumescent seals
having a fire resistance up to 240 minutes (Code IMM/MM).

4. The locks are approved on the basis of:

i. Initial type testing to EN 1634-1 and EN 12209/EN 179 (where relevant)


ii. An appraisal against TS23 or TS31 (where relevant)
iii. Certification of quality management system.
iv. Inspection and surveillance of factory production control
v. On-going audit testing in accordance with TS23 or TS31 requirements

5. This approval relates to the use of the above locks/latches in contributing to the fire
resistance performance of timber based doorsets and predominantly steel-based doorsets,
as defined in BS EN 1634-1 or BS 476: Part 22: 1987. Issued: 6th August 2021
Reissued: 30th April 2024
Signed Page 2 of 8
Valid to: 5th August 2026
J/154

This certificate is the property of Warringtonfire Testing and Certification Limited


Registered in England and Wales
Registered Office: 3rd Floor, Davidson Building, 5 Southampton Street, London, WC2E 7HA. Company Registration No: 11371436
CERTIFICATE No CF 5908
HAGER COMPANIES
3800U SERIES LOCKS
6. EN1634-1 was issued originally in 2000, with amended versions issued in 2008, 2014
and 2018. The differences between each version are mainly procedural and are not
considered to have a practical impact on the performance of the samples under test. On
this basis this evaluation is consider applicable to all versions of EN1634-1 issued prior to
the issue of this certificate.

7. The mortice locks and/or latches should only be used with door assemblies of proven fire
resistance (as defined in BS EN 1634-1 or BS 476: Part 22: 1987) with similar size locks
and strikeplates. The critical aspects of the doorset construction are considered to be the
material of the door frame, the leaf to frame clearance gaps and the lipping material.
Attention should be paid to these details and these should not be amended from that
previously fire tested. The following minimum specification shall be followed:

Timber-based assemblies:

i) Door frame density - 450 kg/m³ (30 minutes), 640 kg/m3 (60 minutes)
ii) Door leaves shall have a minimum thickness of 44 mm for 30 minute applications
and 54 mm for 60 minute applications.
iii) Lipping density - 640 kg/m3.

Steel-based assemblies (Code MM/IMM)

i) Door leaves shall have a minimum thickness of 44 mm for up to 240 minute


applications.
ii) No additional intumescent protection is required.

8. When fitted to insulated timber or mineral composite door assemblies, The required
protection will be as follows:

i) The required protection for 30 minute ITT applications will be 2 mm thick Interdens
mono ammonium phosphate intumescent sheet material around the lock case and
behind the forend and strike plate.

ii) The required protection for 60 minute ITT applications will be 2 mm thick Firestop
graphite-based intumescent sheet material around the lock case and behind the
forend and strike plate. Additionally the perimeter intumescent within the
frame/door edge shall by-pass the strike plate or forend by a minimum of 8 mm
wide on each side (with the exception of the latchbolt lead where present).

Failure to install the protection will invalidate this certificate

Signed Page 3 of 8 Issued: 6th August 2021


Reissued: 30th April 2024
J/154 Valid to: 5th August 2026

This certificate is the property of Warringtonfire Testing and Certification Limited


Registered in England and Wales
Registered Office: 3rd Floor, Davidson Building, 5 Southampton Street, London, WC2E 7HA. Company Registration No: 11371436
CERTIFICATE No CF 5908
HAGER COMPANIES
3800U SERIES LOCKS

9. The mortice locks and/or latches and their associated strikeplates and keeps may only be
fitted in the manner described in this certificate and subject to any limitations on the
inclusion of locks/latches specified for the door leaf. This approval is applicable only to the
specified locks used with door assemblies of proven fire resistance (as defined in BS EN
1634-1 or BS 476: Part 22: 1987) and when using appropriate intumescent protection.

10. The mortice locks and/or latches should only be used with doorsets which have been
previously shown to be capable of providing the required fire resistance performance when
tested in accordance with EN 1634-1 or BS 476: Part 22: 1987 in the proposed
configuration i.e. single-leaf or double-leaf.

11. The locks/latches should not be fitted higher than 1100 mm from the spindle to the finished
floor level of the surrounding floors.

12. Lock assemblies not incorporating a latching mechanism shall only be fitted to proven
unlatched door assemblies.

13. Cylinders shall only be fitted to doors which have previously been shown capable of
accommodating the installation of cylinder locks without detriment to the doorset’s
performance.

14. The mortice locks may incorporate Euro profile cylinders as follows:

i) Single cylinder
ii) Double cylinder
iii) Cylinder and thumbturn
iv) Brass or steel cylinders for ITT30 and 60 doorsets
v) Brass or Steel cylinders only for MM/IMM 240 doorsets

Note: The hole in the door face shall follow the shape of the cylinders and be as tight as
possible; furthermore the single cylinders door preparation will penetrate through only half
the thickness of the door leaf)

15. Recessing for locks shall result in a tight fit, allowing for any intumescent protection
where required. Mortices for the latchbolt and deadbolt behind the strikeplate shall be as
small as possible.

16. The spindle hole through the door shall be a maximum of 15 mm diameter unless the
doorset has test evidence that proves spindle holes of a greater size than this.

17. The doorset shall be installed in accordance with BS 8214

Issued: 6th August 2021


Signed Page 4 of 8 Reissued: 30th April 2024
J/154 Valid to: 5th August 2026

This certificate is the property of Warringtonfire Testing and Certification Limited


Registered in England and Wales
Registered Office: 3rd Floor, Davidson Building, 5 Southampton Street, London, WC2E 7HA. Company Registration No: 11371436
CERTIFICATE No CF 5908
HAGER COMPANIES
3800U SERIES LOCKS

18. The approval relates to on-going production. Product and/or its immediate packaging is
identified with the manufacturer’s name, the product name or number, the CERTIFIRE
name or name and mark, together with the CERTIFIRE certificate number and application
where appropriate.

19. The following table shows the acceptable doorset types and fire resistance periods:

Approved Door Type


Class IMM MM ITT ITM ITC
FD20
    
FD30
    
FD60
    
FD90
    
FD120
    
FD240
    
E 20
    
EI 20
    
E 30
    
EI 30
    
E 60
    
EI 60
    
E 90
    
EI 90
    
E 120
    
EI 120
    
E 240
    
EI 240
    
Key:
 - approved
 - Not approved

Issued: 6th August 2021


Signed Page 5 of 8
Reissued: 30th April 2024
J/154 Valid to: 5th August 2026

This certificate is the property of Warringtonfire Testing and Certification Limited


Registered in England and Wales
Registered Office: 3rd Floor, Davidson Building, 5 Southampton Street, London, WC2E 7HA. Company Registration No: 11371436
CERTIFICATE No CF 5908
HAGER COMPANIES
3800U SERIES LOCKS

20. Doors are classified as the following types:

Code ITT - 20 minute to 120 minute doorsets containing intumescent seals and consisting
of timber faced and edged leaves with timber, cellulosic or mineral cores, hung in timber-
based frames.

Code ITM - 20 minute to 120 minute doorsets containing intumescent seals and consisting
of timber faced and edged leaves with timber, cellulosic or mineral cores, hung in steel
frames.

Code ITC - 20 minute to 120 minute doorsets containing intumescent seals and consisting
of timber faced and edged leaves with timber, cellulosic or mineral cores, hung in
proprietary composite frames, of which the principal material is other than timber or metal
but which may include any other materials.

Code MM - 20 to 240 minute doorsets consisting of uninsulated or insulated predominantly


steel leaves, hung in steel frames without intumescent seals.

Code IMM - 20 to 240 minute doorsets consisting of uninsulated or insulated predominantly


steel leaves, hung in steel frames with intumescent seals.

Approved lock/latch models and classifications.

3800U-55S Sashlock - BS EN 12209: 2003

3 X 5 1 0 F 3 B C 2 0

3800U-55F Deadlock - BS EN 12209: 2003

3 X 5 1 0 F 3 B C 0 0

3800U-55B Bathroom Lock - BS EN 12209: 2003

3 X 5 1 0 F - B G 2 0

3800U-55L Mortice Latch- BS EN 12209: 2003

3 X 5 1 0 F - B 0 2 0

Signed Page 6 of 8 Issued: 6th August 2021


Reissued: 30th April 2024
J/154 Valid to: 5th August 2026

This certificate is the property of Warringtonfire Testing and Certification Limited


Registered in England and Wales
Registered Office: 3rd Floor, Davidson Building, 5 Southampton Street, London, WC2E 7HA. Company Registration No: 11371436
CERTIFICATE No CF 5908
HAGER COMPANIES
3800U SERIES LOCKS

Approved lock/latch models and classifications (continued).

3800U-55M Nightlatch - BS EN 12209: 2003

3 X 5 1 0 F - B 0 2 0

3800U-55T Nightlatch w/ Anti-thrust bolt - BS EN 12209: 2003

3 X 5 1 0 F 2 B B 2 0

3800U-55P Anti-Panic Mortise Lock - BS EN 179: 2008

3 7 6 B 1 3 4 2 A

Scope of approval

• The locks may not be fitted to timber/mineral-based doorsets without perimeter


intumescent fire seals fitted with the frame rebate or door edge.
• ITT door leaves shall have solid lignocellulosic construction in the lock area
encompassing the entire lock case.
• Strikeplates/keeps
o The locks/latches are approved with a range of strikeplates/keeps. All of
which are steel and the a maximum size permitted for use on all doorsets is
as follows:

width 24 mm (exc. Lip)


height 172 mm
thickness 1.5 mm
Latchbolt- lip height 60 mm

• Only the 3800U-55P Escape lock is approved for use as an emergency exit with the
following accessories:
o 6802 Lever Furniture with 2-669-0733 through-spindle

Issued: 6th August 2021


Signed Page 7 of 8 Reissued: 30th April 2024
Valid to: 5th August 2026
J/154

This certificate is the property of Warringtonfire Testing and Certification Limited


Registered in England and Wales
Registered Office: 3rd Floor, Davidson Building, 5 Southampton Street, London, WC2E 7HA. Company Registration No: 11371436
CERTIFICATE No CF 5908
HAGER COMPANIES
3800U SERIES LOCKS

Further Information

Further information regarding the details contained in this certificate may be obtained from Hager
Companies - Tel: (314) 772-4400).

Further information regarding CERTIFIRE certification and other approved products can be
obtained from CERTIFIRE (Tel: 01925 646777).

Signed Page 8 of 8 Issued: 6th August 2021


Reissued: 30th April 2024
J/154
Valid to: 5th August 2026

This certificate is the property of Warringtonfire Testing and Certification Limited


Registered in England and Wales
Registered Office: 3rd Floor, Davidson Building, 5 Southampton Street, London, WC2E 7HA. Company Registration No: 11371436
Certificate of Constancy of Performance
0359-CPR-000331-01

In compliance with Regulation 305/2011/EU of the European Parliament and of the Council
of 9 March 2011 (the Construction Products Regulation), this certificate applies to the
construction product(s).

Product(s): Panic Exit Device


(refer to attached appendix for details and conditions)

Placed on the market Hager Companies, Inc.,


under the trade mark of: 139 Victor Street, St. Louis, Missouri, 63104, U.S.A..

Produced in the A013


manufacturing plant(s):

Intended use: For doors on escape routes.

This certificate attests that all provisions concerning the assessment and
verification of constancy of performance described in Annex ZA of the
standard(s):

EN 1125:2008

Under system 1 for the performance set out in this certificate are applied and that
the performance of the construction product is assessed to remain constant.
th
This certificate was first issued on 15 November 2016 under CPR (305/2011)
and will remain valid as long as neither the harmonised standard, the
construction product, the AVCP methods nor the manufacturing conditions in the
plant are modified significantly, unless suspended or withdrawn by the notified
product certification body.

The issued document and statement(s) herein makes reference only to a


presumption of conformity in accordance with the CPR Regulations EU
305/2011 (as amended). However, it is the manufacturer’s or their authorised
representative’s sole responsibility to affix the CE logo and, by doing so,
0359 confirms full compliance and conformity to all other European mandatory
directives and regulations that may also apply.

Intertek Testing & Certification Limited


Cleeve Road, Leatherhead
David Bigland Date 15 Nov-2016
Surrey, KT22 7SB
Tel: + 44 (0)1372 370900 Certification
Fax: +44 (0)1372 370977 Manager Issue 01
E-mail: [email protected]
Registered No 3272281 Academy Place, 1-9 Brook Street, Brentwood,
www.intertek.com Essex, CM14 5NQ, United Kingdom
This Certificate is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client
in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Certificate. Only the Client is authorized to permit
copying or distribution of this Certificate and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of
the tested material, product or service must first be approved in writing by Intertek.
Page 1 of 5
Certificate of Constancy of Performance
0359-CPR-000331-01
Appendix to Certificate of Constancy of Performance 0359-CPR-000331-01

Model Ref: Panic Exit device: 4201R-32D, 4201R-ALM, 4201S-32D, 4201S-ALM

Table A1. Model number details for Panic Exit Device from Hager Companies, Inc.

Double door Lock &


Model list Single door Material (Touch Bar)
Active door Inactive door Latch type

4201R-ALM   -- Rim Latch Carbon Steel


4201R-32D   -- Rim Latch Stainless steel
4201S-ALM -- --  Vertical Bolt Carbon Steel
4201S-32D -- --  Vertical Bolt Stainless steel
Accessories
42KE Lever Outside access device
42CE Lever Outside access device

Notes:
1. The panic exit device(s) are to be installed in accordance with the installation instructions for the
product(s).
2. This certificate of constancy of performance refers to the requirements for the product(s) described
under the CPR. There may be other European Directives, where requirements need to be declared
before CE marking can be affixed by the manufacturer or their authorised representative.
3. Products tested for use on metal doors and frames, as described in fire resistance test reports (see
summary Table A.3
4. Product code ALM – designation represents mild steel cover
5. Product code 32D – designation represents stainless steel cover

Table A2. Mechanical test reports and product classification for Panic Exit Devices from Hager
Companies, Inc.

Mechanical test
reports Model list Product Classification

1
4201R-ALM 3 7 6 B 1 4 2 2 B A
1
4201R-32D 3 7 6 B 1 4 2 2 B A
161107112GZU-001 1
4201S-ALM 3 7 6 B 1 4 2 2 B C
1
4201S-32D 3 7 6 B 1 4 2 2 B C

Notes.
1. Digit 4 grade “B” was based on the test result from fire resistance test(s) (refer to Table A3).

Intertek Testing & Certification Limited, Cleeve Road, Leatherhead, Surrey, KT22 7SB 0359-CPR-000331-01
Tel: + 44 (0)1372 370900, Fax: +44 (0)1372 370977, E-mail: [email protected] Issue: 01

Registered No 3272281 Academy Place, 1-9 Brook Street, Brentwood, Essex,


www.intertek.com CM14 5NQ, United Kingdom
This Certificate is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility
and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with
the agreement, for any loss, expense or damage occasioned by the use of this Certificate. Only the Client is authorized to permit copying or distribution of
this Certificate and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or
service must first be approved in writing by Intertek.
Page 2 of 5
Certificate of Constancy of Performance
0359-CPR-000331-01
Table A3. Fire test reports for Panic Exit Device from Hager Companies, Inc.

Fire Resistance
Fire Test Reports Model list Test Method (minutes)
Integrity (E) Insulation (I)

161107112GZU-001 4201R-ALM EN 1634-1:2014 60 60

Test configuration: Single Action Single Door, timber fire door assembly
Orientation: Open into the furnace
Model numbers assessed as having same performance: 4201R-32D
161107112GZU-001 4201S-ALM EN 1634-1:2014 60 60
Test configuration: Single Action Single Door, timber fire door assembly
Orientation: Open into the furnace
Model numbers assessed as having same performance: 4201S-32D

161107112GZU-001 4201R-ALM EN 1634-1:2014 62 62

Test configuration: Single Action Single Door, timber fire door assembly
Orientation: Open away from the furnace.
Model numbers assessed as having same performance: 4201R-32D
161107112GZU-001 4201S-ALM EN 1634-1:2014 90 90
Test configuration: Single Action Single Door, timber fire door assembly
Orientation: Open away from the furnace
Model numbers assessed as having same performance: 4201S-32D
4201R-ALM (active door)
161107112GZU-001 EN 1634-1:2014 70 70
4201S-ALM (inactive door)
Test configuration: Single Action Double Door, timber fire door assembly
Orientation: Open into the furnace
Model numbers in pair assessed as having same performance: (4201R-32D, 4201S-32D)
4201R-ALM (active door)
161107112GZU-001 EN 1634-1:2014 70 70
4201S-ALM (inactive door)
Test configuration: Single Action Double Door, timber fire door assembly
Orientation: Open away from the furnace
Model numbers in pair assessed as having same performance: (4201R-32D, 4201S-32D)

Intertek Testing & Certification Limited, Cleeve Road, Leatherhead, Surrey, KT22 7SB 0359-CPR-000331-01
Tel: + 44 (0)1372 370900, Fax: +44 (0)1372 370977, E-mail: [email protected] Issue: 01

Registered No 3272281 Academy Place, 1-9 Brook Street, Brentwood, Essex,


www.intertek.com CM14 5NQ, United Kingdom
This Certificate is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility
and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with
the agreement, for any loss, expense or damage occasioned by the use of this Certificate. Only the Client is authorized to permit copying or distribution of
this Certificate and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or
service must first be approved in writing by Intertek.
Page 3 of 5
Certificate of Constancy of Performance
0359-CPR-000331-01
Table A4. Panic Exit Device - EN 1125 Table ZA.1 Clauses for panic exit device (Hager Brand)
Product: Panic exit devices (4201R-32D, 4201R-ALM, 4201S-32D, 4201S-ALM)
Intended uses: For doors on escape routes.
Requirement / Requirement clauses in this Results
characteristic European Standard
Ability to release 4.1.2 Release function < 1 second
(for doors on 4.1.3 Panic exit device mounting Surface mounted on inner face of door leaf.
escape routes)
4.1.5 Exposed edges and corners No sharp edges
4.1.7 Double doorset Pass
4.1.9 Bar installation Z < 150 mm
4.1.10 Bar length X/Y> 60%
4.1.11 Bar projection Standard projection Category 2: W <100 mm
4.1.12 Bar end The operating bar does not protrude beyond
either of the end support brackets
4.1.13 Operating bar face V > 18 mm
4.1.14 Test rod Pass, The device does not trap the test rod in any
position of the operating bar
4.1.15 Door face gap R > 25 mm
4.1.16 Accessible gap The test piece placed in any accessible gap
cannot prevent the correct operation of the device

4.1.17 Door free movement The device does not include any element
impeding the free movement of the door once it is
released
4.1.18 Top vertical bolt Pass
(4201S-ALM, 4201S-32D only)
4.1.20 Keepers The keeper protects the door frame from the
damage caused by the door closing and opening

4.1.21 Keepers dimensions Pass


(4201S-ALM, 4201S-32D only)
4.1.23 Door mass and dimensions Mass 200 Kg, height ≤ 2500 mm, width 650 to
1320 mm (dimensions mechanical only)
4.1.24 Outside access device Pass(Where included as part of test)
4..2.2 Release forces < 80 N with the door unloaded
< 220 N with the door loaded with 1 000 N
4.2.7 Security requirement Grade 2: the device remains locked when a force
of 1 000 N is applied to the door

Intertek Testing & Certification Limited, Cleeve Road, Leatherhead, Surrey, KT22 7SB 0359-CPR-000331-01
Tel: + 44 (0)1372 370900, Fax: +44 (0)1372 370977, E-mail: [email protected] Issue: 01

Registered No 3272281 Academy Place, 1-9 Brook Street, Brentwood, Essex,


www.intertek.com CM14 5NQ, United Kingdom
This Certificate is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility
and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with
the agreement, for any loss, expense or damage occasioned by the use of this Certificate. Only the Client is authorized to permit copying or distribution of
this Certificate and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or
service must first be approved in writing by Intertek.
Page 4 of 5
Certificate of Constancy of Performance
0359-CPR-000331-01
Durability of 4.1.4; 4.2.9 Corrosion resistance Grade 4: Very high resistance (240 hours)
ability to release 4.1.6 Temperature range -10°C; +60°C
against aging
and degradation 4.1.19 4.2.6 Covers for vertical NPD (No Declare Performance)
(for doors on rods
escape routes) 4.1.22 Lubrication Refer to Manufacturer’s Maintenance Instructions
4.2.3 Re-engagement force < 50 N
4.2.4 Durability Grade 7
200 000 test cycles
4.2.5 Abuse resistance – Pass
Horizontal bar
4.2.6 Abuse resistance –Vertical Pass
rod (4201S-ALM, 4201S-32D only)
4.2.8; 4.2.2; 4.1.17 Final The device is released with a force
examination < 80 N, with the door unloaded, and
< 220 N, with the door loaded with 1 000 N, and
the door moves freely
Self closing 4.2.3 Re-engagement force < 50 N
ability C (for
fire/smoke doors
on escape routes)
Durability of self 4.2.4 Durability Grade 7
closing ability C
200 000 test cycles
against aging
and degradation 4.2.3 Re-engagement force
(for fire/smoke < 50 N
doors on escape
routes)
Resistance to 4.1.8; Annex B Suitability of panic Grade B: suitable for use on fire/smoke resisting
fire E (integrity) exit devices for use on fire/smoke door assemblies (see Table A3).
and (insulation) resisting door assemblies –
(for fire doors on
escape routes)
Control of 4.1.25 dangerous substances No dangerous substances declared for this
Dangerous product/intended use
substances
END OF DOCUMENT

Intertek Testing & Certification Limited, Cleeve Road, Leatherhead, Surrey, KT22 7SB 0359-CPR-000331-01
Tel: + 44 (0)1372 370900, Fax: +44 (0)1372 370977, E-mail: [email protected] Issue: 01

Registered No 3272281 Academy Place, 1-9 Brook Street, Brentwood, Essex,


www.intertek.com CM14 5NQ, United Kingdom
This Certificate is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility
and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with
the agreement, for any loss, expense or damage occasioned by the use of this Certificate. Only the Client is authorized to permit copying or distribution of
this Certificate and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or
service must first be approved in writing by Intertek.
Page 5 of 5
CERTIFICATE OF APPROVAL
No CF 5288
This is to certify that, in accordance with
TS00 General Requirements for Certification of Fire Protection Products
The undermentioned products of
1

HAGER COMPANIES INC.


139 Victor Street, St. Louis, MO 63104, U.S.A.
Tel: 314-772-4400
Have been assessed against the requirements of the Technical Schedule(s)
denoted below and are approved for use subject to the conditions
appended hereto:
_____________________________________________________________________________________________________

CERTIFIED PRODUCT TECHNICAL SCHEDULE


Stainless Steel Ball TS24 The Contribution of
Bearing Hinges Single Axis Hinges to the Fire
Resistance of Door Assemblies

Signed and sealed for and on behalf of Warringtonfire Testing and Certification Limited

Paul Duggan
Certification Manager

th
Issued: 20 November 2015
st
Revised: 1 September 2022
st
Valid to: 31 August 2027
Page 1 of 5

This certificate is the property of Warringtonfire Testing and Certification Limited


Registered in England and Wales
Registered Office: 3rd Floor, Davidson Building, 5 Southampton Street, London, WC2E 7HA. Company Registration No: 11371436
CERTIFICATE No CF 5288
HAGER COMPANIES INC.
Hager Companies Inc. Stainless Steel Ball Bearing Hinges

1. This certification is provided to the client for their own purposes and we cannot opine on
whether it will be accepted by Building Control authorities or any other third parties for
any purpose.

2. The BB6191 range of Grade 13 stainless steel, single axis ball bearing hinge approved
are as follows:

Reference Description

4030B 102 x 75 x 3 mm – Square corner

4035B 102 x 90 x 3 mm – Square corner

4040B 102 x 102 x 3 mm – Square corner

5035BB 127 x 90 x 3 mm – Square corner

3. This approval relates to their use with the following door assemblies:-

Latched and unlatched, intumescent sealed door assemblies consisting of timber


faced and edged leaves with timber, cellulosic or mineral cores, in timber frames
having a fire resistance of 60 minutes only (Code ITT).

Latched and unlatched, door assemblies consisting of uninsulated or insulated


predominantly steel leaves, hung in steel frames with or without intumescent seals
having a fire resistance up to 240 minutes (Code IMM/MM).

4. The hinges are approved on the basis of:

i) Initial type testing to EN1935 and EN 1634-1


ii) An appraisal against TS24
iii) Certification of quality management system.
iv) Inspection and surveillance of factory production control
v) On-going audit testing in accordance with TS24 requirements

5. The door assembly shall be a CERTIFIRE approved product or have achieved the
appropriate fire resistance performance when tested at a UKAS accredited laboratory in
accordance with BS 476: Part 22: 1987 and/or BS EN 1634:1 with hinges of a similar
size.

th
Issued: 20 November 2015
Page 2 of 5 Signed st
Revised: 1 September 2022
J/039 Valid to:
st
31 August 2027

This certificate is the property of Warringtonfire Testing and Certification Limited


Registered in England and Wales
Registered Office: 3rd Floor, Davidson Building, 5 Southampton Street, London, WC2E 7HA. Company Registration No: 11371436
CERTIFICATE No CF 5288
HAGER COMPANIES INC.
Hager Companies Inc. Stainless Steel Ball Bearing Hinges

6. The hinges should only be used with door assemblies of proven fire resistance (as
defined in BS EN 1634-1 or BS 476: Part 22: 1987) with similar hinges, the critical
aspects of the doorset construction are considered to be the material of the door frame,
the leaf to frame clearance gaps and the lipping material. Attention should be paid to
these details and these should not be amended from that previously fire tested. Where
this information is not known the following minimum specification will be followed:

a. 60 minute timber and mineral-based assemblies (ITT):

i) Door frame density - 640 kg/m3 (60 minutes)


ii) Door leaves shall have a minimum thickness of 54 mm.
iii) Lipping density - 640 kg/m3.

b. Steel-based assemblies (MM/IMM)

i) Door leaves shall have a minimum thickness of 44 mm for up to 240 minute


applications.
7. When fitted to 60 minute insulated timber or mineral composite door assemblies, the
required additional intumescent protection will be as follows:

i) The required protection for 60 minute ITT applications will be 2 mm thickness of


mono ammonium phosphate or graphite-based intumescent sheet material (see
‘Scope of Approval’ below) behind both blades.
Failure to install the protection will invalidate this certificate

8. The hinges may only be fitted in the manner described in this certificate and subject to
any limitations on the inclusion of hinges specified for the door leaf. This approval is
applicable only to the specified hinges used with door assemblies of proven fire
resistance (as defined in BS EN 1634-1 or BS 476: Part 22: 1987) and when using
appropriate intumescent protection.

9. Regard should be paid to the maximum door mass permitted to be used with the hinge
(see classifications).

10. For ITT timber and mineral-based doorsets the hinges shall only be fitted using the
fixings supplied by the hinge manufacturer.

11. The ITT doorsets shall be installed in accordance with BS 8214.

th
Issued: 20 November 2015
Page 3 of 5 Signed st
Revised: 1 September 2022
J/039 Valid to:
st
31 August 2027

This certificate is the property of Warringtonfire Testing and Certification Limited


Registered in England and Wales
Registered Office: 3rd Floor, Davidson Building, 5 Southampton Street, London, WC2E 7HA. Company Registration No: 11371436
CERTIFICATE No CF 5288
HAGER COMPANIES INC.
Hager Companies Inc. Stainless Steel Ball Bearing Hinges

12. The approval relates to ongoing production. The product and/or its immediate packaging
is identified with the manufacturer’s name, the product name or number, the CERTIFIRE
name or name and mark, together with the CERTIFIRE certificate number and
application where appropriate.

13. The following table show acceptable doorset types and fire resistance periods:

Approved Door Type


Class IMM MM ITT ITM
FD20    
FD30    
FD60    
FD90    
FD120    
FD240    
E 20    
EI 20    
E 30    
EI 30    
E 60    
EI 60    
E 90    
EI 90    
E 120    
EI 120    
E 240    
EI 240    
Key:

 - approved
 - Not approved

th
Issued: 20 November 2015
Page 4 of 5 Signed st
Revised: 1 September 2022
J/039 Valid to:
st
31 August 2027

This certificate is the property of Warringtonfire Testing and Certification Limited


Registered in England and Wales
Registered Office: 3rd Floor, Davidson Building, 5 Southampton Street, London, WC2E 7HA. Company Registration No: 11371436
CERTIFICATE No CF 5288
HAGER COMPANIES INC.
Hager Companies Inc. Stainless Steel Ball Bearing Hinges

14. Doors are classified as the following types:

Code ITT - 20 minute to 120 minute doorsets containing intumescent seals and
consisting of timber faced and edged leaves with timber, cellulosic or mineral cores, hung
in timber-based frames.

Code ITM - 20 minute to 120 minute doorsets containing intumescent seals and
consisting of timber faced and edged leaves with timber, cellulosic or mineral cores, hung
in metal frames.

Code MM - 20 to 240 minute doorsets consisting of uninsulated or insulated


predominantly steel leaves, hung in steel frames without intumescent seals.

Code IMM - 20 to 240 minute doorsets consisting of uninsulated or insulated


predominantly steel leaves, hung in steel frames with intumescent seals.

Scope of Approval:

 The hinges may not be fitted to timber doorsets without perimeter intumescent fire
seals within the frame rebate or edge of the door leaf.

 Where graphite based intumescent sheet material is to be used in lieu of the mono
ammonium phosphate tested, the proposed graphite-based intumescent sheet
material, shall have suitable test evidence in the required thickness or less, with
timber/mineral-based doorset of the required classification period, in with steel
hinges of a minimum size of 100 mm x 75 mm.

Classification codes

The above approval provides the following classifications:

4 7 6 1 1 4 0 13
Further Information

Further information regarding the details contained in this certificate may be obtained from
Hager Companies Inc. (Tel: + 314 772 4400).

Further information regarding CERTIFIRE certification and other approved products can be
obtained from CERTIFIRE (Tel: 01925 646777).

th
Issued: 20 November 2015
Page 5 of 5 Signed st
Revised: 1 September 2022
J/039 Valid to:
st
31 August 2027

This certificate is the property of Warringtonfire Testing and Certification Limited


Registered in England and Wales
Registered Office: 3rd Floor, Davidson Building, 5 Southampton Street, London, WC2E 7HA. Company Registration No: 11371436
11/22/23, 2:27 PM GVEV.R16837 - Swinging Fire Door Closers | UL Product iQ

Swinging Fire Door Closers

COMPANY

HAGER COMPANIES
139 VICTOR ST
SAINT LOUIS, MO 63104-4724 United States

R16837

For self closing door closers, without hold-open feature, surface mounted type, size 2-6 Model(s) 5100, 5200, 5300

For self-closing doors, without hold-open feature, surface mounted type, sizes 2-6 Model(s) 5200

Additionally Investigated to Standard UL 10C.

For self-closing doors, surface mounted type, without hold-open feature Model(s) 5100, 5200, 5300, 5400

For self-closing doors, without hold-open feature, surface mounted Model(s) 5100

Last Updated on 2023-08-03

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL Solutions' Follow - Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL
Solutions' Follow - Up Service. Always look for the Mark on the product.

UL Solutions permits the reproduction of the material contained in Product iQ subject to the following conditions: 1. The Guide Information,
Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner,
without any manipulation of the data (or drawings). 2. The statement "Reprinted from Product iQ with permission from UL Solutions" must appear
adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "©2023 UL LLC."

https://iq.ulprospector.com/en/profile?e=42942 1/1
11/21/23, 5:16 PM GVWZ.R13647 - Gasketing Materials for Fire Doors | UL Product iQ

Gasketing Materials for Fire Doors

COMPANY

HAGER COMPANIES
139 VICTOR ST
SAINT LOUIS, MO 63104-4724 United States

R13647

Astragals, intended for use with hollow metal and steel covered composite type fire doors rated up to and including 3 h; wood covered
composite and wood core doors rated up to 1-1/2 h Model(s) 756, 771, 772, 774, 775, 776, 802, 835, 837, 839, 845, 846, 847, 848, 872, 874, 882,
884

Automatic door bottoms, intended for application to/with classified hollow metal and steel covered composite type fire doors rated up
to and including 3 hrs Model(s) 742SN, 742SV

Automatic door bottoms, intended for use with hollow metal and steel covered composite type fire doors rated up to and including 3 h;
wood covered composite and wood core doors rated up to 1-1/2 h Model(s) 730

Automatic door bottoms, intended for use with hollow metal and steel covered composite type fire doors rated up to and including 3 h;
wood covered composite and wood core doors rated up to 1-1/2 h Model(s) 740, may be installed as either surface mounted or half-mortised.

Automatic door bottoms, intended for use with hollow metal and steel covered composite type fire doors rated up to and including 3 h;
wood covered composite and wood core doors rated up to 1-1/2 h Model(s) 742, 743

Automatic door bottoms, intended for use with hollow metal and steel covered composite type fire doors rated up to and including 3 h;
wood covered composite and wood core doors rated up to 1-1/2 h Model(s) 747, may be installed as either surface mounted or half-mortised.

Brush type, intended for use with listed steel fire door frames and/or classified steel covered composite, hollow metal, rolling steel,
passenger elevator type fire doors rated up to 3 h; wood covered composite and wood core doors rated up to 1-1/2 h Model(s) 800, 801,
802, 803, 806, 808

Door sweep bottoms, intended for use with hollow metal and steel covered composite type fire doors rated up to and including 3 h;
wood covered composite and wood core doors rated up to 1-1/2 h Model(s) 750, 751, 752, 753, 754, 756, 759, 770, 771, 772, 774, 776, 777,
778, 779, 780, 781, 782, 783, 785, 787, 789, 801, 802, 806, 872, 882, 883, 884

Gasketing materials, automatic door bottom, for use on listed steel frames and/or classified hollow metal and steel covered composite
type fire doors rated up to 3 h, wood composite up to 1-1/2 h and wood core type rated 20 min without hose stream Model(s) 742S

Gasketing materials, door sweeps, for use on classified hollow metal or steel covered composite type fire doors rated up to 3 h, wood
composite up to 1-1/2 h and wood core type rated twenty minutes without hose stream Model(s) 752S, 759S

Gasketing materials, door sweeps, for use on Classified hollow metal or steel covered composite type fire doors rated up to 3 h; wood
composite up to 1-1/2 h; wood core type rated 20 min without hose stream Model(s) 906SN, 907S0, 907SN, 908S0, 908SN, 909S0, 909SN

Gasketing materials, perimeter seal, for Classified steel covered composite hollow metal type fire door rated up to and incl 3 h; wood
type fire door rated up to and incl 1/3 h; wood and plastic covered composite fire doors rated up to and incl 1-1/2 h Model(s) 738

Gasketing materials, threshold, intended for use with hollow metal and steel covered composite type fire doors rated up to and including
3 h; wood covered composite and wood core doors rated up to 1-1/2 h Model(s) 401 (a), 402 (a), 403 (a), 404 (a), 406 (a), 407 (a), 408 (a), 409
(a), 410 (a), 411 (a), 412 (a), 413 (a), 415 (a), 416 (a), 417 (a), 418 (a), 419 (a), 420 (a), 421 (a), 422 (a), 423 (a), 424 (a), 426 (a), 427 (a), 428 (a), 429 (a),
430 (a), 431 (a), 432 (a), 433 (a), 434 (a), 435 (a), 436 (a), 438 (a), 440 (a), 442 (a), 443 (a), 444 (a), 445 (a), 450 (a), 451 (a), 452 (a), 455 (a), 460 (a), 465
(a), 471 (a), 474 (a), 477 (a), 478 (a), 481 (a), 483 (a), 484 (a), 492 (a), 500 (a), 501 (a), 503 (a), 504 (a), 505 (a), 506 (a), 507 (a), 516 (a), 518 (a), 520 (a),
532 (a), 541 (a), 552 (a), 560 (a), 565 (a), 572 (a), 575 (a), 580 (a), 599 (a), 600 Series (a)

https://iq.ulprospector.com/en/profile?e=43731 1/2
11/21/23, 5:16 PM GVWZ.R13647 - Gasketing Materials for Fire Doors | UL Product iQ
Interlocking, intended for use with hollow metal and steel covered composite type fire doors rated up to and including 3 h; wood
covered composite and wood core doors rated up to 1-1/2 h Model(s) 701, 711, 713S, 715S, 716S, 717S, 718S

Jamb up seals, intended for use with hollow metal and steel covered composite type fire doors rated up to and including 3 h; wood
covered composite and wood core doors rated up to 1-1/2 h Model(s) 785, 800, 802, 803, 808, 858, 860, 861, 862, 863, 864, 865, 866, 870, 871,
872, 873, 874, 875, 877, 878, 880, 881, 882, 885, 887, 890, 891, 892, 893, 894, 896

Overhead door protection types, for use with hollow metal and steel covered composite type fire doors rated up to and including 3 h;
wood covered composite and wood core doors rated up to 1-1/2 h Model(s) 717 (b), 718 (b), 785 (b), 787 (b)

Perimeter seals, for use with classified wood and plastic covered composite and wood core doors rated up to 1-1/2 h; listed steel frames
and/or classified steel covered composite, hollow metal doors rated up to 3 h Model(s) 719, 720, 722, 724, 729, 734

Press-on, intended for use with hollow metal and steel covered composite type fire doors rated up to and including 3 h; wood covered
composite and wood core doors rated up to 1-1/2 h Model(s) 715, 718, 725, 726, 728, 729, 736, 737

Self-adhesive perimeter seals, for use with classified wood and plastic covered composite and wood core doors rated up to 1-1/2 hr., and
listed steel frames and/or classified steel covered composite, hollow metal doors rated up to 3 h Model(s) 721

(a) - With suffix letters S, SN, SS, SV or SW.

(b) - May have suffix or prefix letter.

Note - Gasketing may have suffix letters S, SN, SS or SV.

Last Updated on 2022-01-28

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL Solutions' Follow - Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL
Solutions' Follow - Up Service. Always look for the Mark on the product.

UL Solutions permits the reproduction of the material contained in Product iQ subject to the following conditions: 1. The Guide Information,
Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner,
without any manipulation of the data (or drawings). 2. The statement "Reprinted from Product iQ with permission from UL Solutions" must appear
adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "©2023 UL LLC."

https://iq.ulprospector.com/en/profile?e=43731 2/2
6/22/23, 6:31 PM GXSR.R13676 - Flush and Surface Bolts, Manual Type | UL Product iQ

Flush and Surface Bolts, Manual Type


See General Information for Flush and Surface Bolts, Manual Type

HAGER COMPANIES R13676


139 VICTOR ST
SAINT LOUIS, MO 63104-4724 USA
Manual flush bolt, Model 282D with 3/4 in. throw for hollow-metal, metal clad, steel covered composite and flush type sheet metal doors.

Manual flush bolt, Model 283D with 3/4 in throw for use on wood covered composite type fire doors.

Manual surface bolts, Models 275-D-8 , 276-D-12 with 1 in. throw for hollow metal, metal clad steel covered composite and flush type sheet
metal doors.

Last Updated on 1996-01-27

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL Solutions' Follow - Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL
Solutions' Follow - Up Service. Always look for the Mark on the product.

UL Solutions permits the reproduction of the material contained in Product iQ subject to the following conditions: 1. The Guide Information,
Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner,
without any manipulation of the data (or drawings). 2. The statement "Reprinted from Product iQ with permission from UL Solutions" must appear
adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "©2023 UL LLC."

Feedback

https://iq.ulprospector.com/en/profile?e=44363 1/1

You might also like