str1
str1
FOOTING
REINFORCEMENT DETAILS
LxB A D No.
MARKS
h r b1 b2 t1 t2
F1 7'0" x 7'0" 2'3" 1'8" 11 12Ø @ 5" C/C 12Ø @ 5" C/C
F2 6'0" x 6'0" 2'3" 1'6" 5 12Ø @ 6" C/C 12Ø @ 6" C/C
CF1 8'6" x 11'0" 2'3" 1'10" 1 12Ø @ 6" C/C 12Ø @ 6" C/C 12Ø @ 6" C/C 12Ø @ 6" C/C
C
L as/detail
1 2 3 4 5
40'
A
15'-10"
A
PCC
C1 C1 6" 6"
3'
B
C1 C1
F1 F1 B
CF1
3'
14'-10"
14'-10"
F1 F1
X X
10'-10"
3'-4"
C C
3'
3'
C C
L L
C1
3'-8"
C1 C1
3'
3'
F1 F1 F1 F1
9'-1"
9'-1"
41'-2"
11'
42'
42'
3 N0s. 8Ø
D D
10Ø @6" C/C
1'-11"
1'-11"
3'
E C1 C1 E
C1 C1 Binder
3'
F1 F1
F1 F1
13'-9"
11'-10"
15'-4"
15'-4"
2'0"
3'
3'
F F
C1 C1
3'
3'
3'-6"
3'
3'
G F1 F1 G
C1
3'
3'
F1 F1
1 2 3 4 5
D D
SECTION FOR LIFT PIT
C
L
TYP DETAIL OF ISOLATED FOOTING
NOTES:-
8Ø Stirrups
(as/arch.) as/detail
EXIST. G.L.
Plinth Beam
as/detail
3 N0s. 8Ø
Binder
Ld<57Ø
10Ø @4" C/C min.
18"