NCT-196 Setup
NCT-196 Setup
ATTENTION
To enable setting adjustment, remove the cover of the NCT-196N DSC/NBDP MODEM
and insert the switch(S1)-No.3 into the OFF. When adjustment is complete, re-insert
the switch(S1)-No.3 into the ON and replace the cover.
S1 S1
8
7
7
6
6
5
5
4
4
3
3
2
2
OFF
OFF
1
1
Insert the S1-3 to Re-insert the
OFF at the time of S1-3 to ON after
Self-ID setting. Self-ID setting.
Procedure
(a) Both press MENU and “POWER SWITCH” to access the following the “INSTALLATIONSETUP”
menu.
INSTALLATION SETUP
Self-ID : 111111111
Group-ID : 022222222
Navigation : NMEA0183
Serial cont: ON
Data clear : OFF
SPACE signal send
MARK signal send
DOT signal send
70-TIME MESSAGE send
WKR frequency : 2,187.5
WKR step test
History
54
(b) Select “Self-ID” using ▼ / ▲ , input the Self-ID (9-digit) using the number keys and
press ENT .
(c) If a Group-ID is assigned, select “Group-ID” using ▼ / ▲ , input the Group-ID (8-digit) and
press ENT .
(d) Select “Navigation” using ▼ / ▲ , specify the navigation data format using / and
press ENT .
ATTENTION
There are two types of navigation data formats, NMEA 0183 and JRC format. For
normal operation, specify NMEA 0183.
NMEA0183 format
(A) Transmission format
Transmission method: Asynchronous
baud rate : 4800bps
Start bit : 1bit
Data bit : 8bit
Stop bit : 1bit
Parity : None
(B) Data format
GLL : Position data ( Lat / Lon ) and UTC time data (IEC61162-1)
Position data ( Lat / Lon ) (NMEA Version 1.5)
ZDA : UTC time data and date ( year, month, day ) data (IEC61162-1)
ZLZ : UTC time data (NMEA Version 1.5)
ZZU : UTC time data (NMEA Version 1.5)
VHW : Water speed and heading data (IEC61162-1)
VTG : Course over ground and ground speed (IEC61162-1)
RMC : Position data ( Lat / Lon ), UTC time data,
and ( year, month, day ) data (IEC61162-1)
JRC format
(A) Transmission format
Transmission method: Asynchronous
baud rate : 1200bps
Start bit : 1bit
Data bit : 8bit
Stop bit : 2bit
Parity : None
(e) Select “Serial cont” using ▼ / ▲ , specify “ON” using / and press ENT .
(f) Press FUNC and then 9 (SAVE). The contents of the settings are written to memory
(saved) and the “DSC watching” display returns. This completes the operation setting.
Note Press FUNC and then 4 (QUIT) to cancel the set contents and end the setting operation.
55