BE-LAB Course Information Sample. (1)
BE-LAB Course Information Sample. (1)
Course Information
The aim of this course is to help the student to attain the following industry identified
competency through various teaching learning experiences:
Design electrical installation systems in building complexes.
At the end of the course, a student will be able to :
EEPC 307.1 Select accessories, wires, cables and wiring systems for electrification.
EEPC 307.2 Design electrical wiring installation system for residential unit.
PREREQUISITES
installations wire,
earthing
lead, fault
current,
leakage
current,
Sessi Different Cable Luminous flux Simple light Lighting and Measuremen
on 4 types of insulation of different and fan power circuits: t of earth
Holders materials types of light circuits Light and fan resistance
sources. circuit, Power using earth
circuit tester,
Methods of
reducing
earth
resistance,
Methods of
earthing and
procedure-
Driven pipe,
pipe and
plate
earthing,
modern
methods of
earthing
Sessi Different Selection of Lux level Stair case Wiring and
on 5 types of suitable cable required for wiring, Go- circuit
socket size and type different down wiring Schematic
outlets and from places as per circuit diagram
plugs standard SP 72: 2010 according to
data. IS: 2042(Part-
I)-1962:
multiline and
single line
representation
Sessi ceiling rose, Cable jointing Lighting Bedroom Load
on 6 distribution methods and design of a lighting assessment:
box, neutral Cable laying room for circuit Selection of
link, bus-bar methods estimation of Corridor size of
chamber lamps lighting conductor,
circuit Selection of
Series rating of main
parallel switch and
circuit, protective
Master switch switch gear.
control circuit
Sessi Intermediate Design and
on 7 switch, Call drawing,
bell circuit estimation and
using bell costing of a
indicator residential
installation
having
maximum 5
KW load;
Sequence to
be followed for
preparing
estimate;
Calculation of
length of wire
and other
materials,
labour cost
Sessi Testing of
on 8 wiring
installation as
per IS: 732-
1982:
Insulation
resistance -
between earth
and
conductors,
between
conductors,
polarity test of
single pole
switches.
Testing of
earth
continuity path
Sessi Residential
on 9 building
Service
Connection-
types
Underground
and overhead.
Calculation of
Material
required for
service
connection.
Sessi
on 10
Sessi
on 11
Sessi
on 12
Sessi
on 13
* Number of session may vary subject to the requirement (quarries) of the students.
Books:
Electrical and Electronics Measurement and Instrumentation by A.K.Sawhney (Dhanpat Rai & Co)
Electrical Measurements and Measuring Instruments by M.L.Anand