Cross-Connect
Rack Framework and
Accessories
Seventh Edition
Table of Contents
8/00 35
261
Table of Contents
CHANNEL RACKS
Framework (Overhead Supported) ....................................................................................... 24
Framework (Floor Supported) .............................................................................................. 25
Accessories ..................................................................................................................... 26-30
Traditionally, as DSX frameworks grew, DSX chassis and the jumper rings associated
Description with them were added one by one. Existing cross-connect jumpers had to be fed into
the new jumper rings as the new chassis were installed. Jumper movement in any one
direction was often restricted since jumper rings were not present at unequipped chassis
positions. If jumpers were pulled too tightly across unequipped positions, feeding them
into new rings was difficult if not impossible. Also, jumpers may have cut across corners
as they transitioned from vertical to horizontal wireways.
To solve these problems and greatly ease the process of growing a DSX lineup, ADC
offers skeleton bays, preassembled with all cable and jumper management, but no
chassis or modules. Bay spacers, end guards and other miscellaneous hardware are
ordered as required. Pre-provisioning all cable management ensures that existing
jumpers need never be touched when chassis are added to the bay. Jumper routing is
never restricted since all wireways are pre-provisioned.
DSX cross-connect system configurations are available for 7' (2.14 m) office environ-
ments. Configurations for 9' (2.75 m) and 11.6' (3.51 m) offices are available upon
request.
A SMALL system (12" [30.48 cm] deep) is designed for offices with limited capacity. A
LARGE (15" [38.1 cm] deep) system is designed with additional jumper capacity for
lineups with greater growth potential; the additional 3" (7.62 cm) of depth provides over
50% additional capacity in the upper and lower jumper troughs.
• Unequal flange type bays are recommended to provide vertical cable ducts for IN/OUT cables.
• Rack spaces over the 7' (2.14 m) high level are generally not used. If taller racks are used, install DSX modules
up to the 7' (2.14 m) level, leaving area above this level vacant. This eliminates the need for ladders for
monitoring circuits.
• Rack spacers on each side of the bay should be provided to allow for adequate room for IN/OUT cables.
• Fuse panels should be placed in the uppermost part of the bay, below horizontal wireways for both rear and
front cross-connects.
• The maintenance bay is typically placed in every third or fourth location of the lineup.
• Cross aisle panels should be provided or space reserved in each bay unless there will never be more than one
lineup.
• An upper and lower horizontal wireway should be provided in each bay for routing cross-connects between
bays in the lineup.
• Horizontal wireways should be at the same height in each bay throughout the lineup.
• Maximum equipment cable length for DS1 signals is 655' (200 m). Limits vary depending on the type of cable
used.
8/00 1
261
DSX-1 Skeleton Bays
Rear Cross-
The rear cross-connect network style skeleton bays, are preassembled with a
Connect fuse panel and all cable and jumper management, but no chassis or modules.
Miscellaneous and maintenance type equipment such as bridging office repeat-
ers, cross aisle panel, interbay patch panel, equipment shelf for portable test set,
communications panel, pencil and storage drawers, etc., may be substituted for
a chassis.
In multiple lineup systems, the top two chassis positions in each bay should be
reserved for a cross aisle panel for extending cross-connects to other lineups.
26" 26"
BAY WIDTH BAY WIDTH
7' HEIGHT
7' HEIGHT
12"
15"
DEPTH
DEPTH
2 8/00
261
DSX-1 Skeleton Bays
Rear Cross- Skeleton bays are designed for use with the 4" and 5"
Connect high DSX-1 chassis.
Note: See ADC Catalog 256, DSX-1 Digital Signal Cross-Connect Modules and Panels
for panel descriptions and choices.
Common Features
• Equipped with fuse panel, upper and lower horizontal jumper trough, vertical jumper rings on
rear of bay
• Accommodates 4" and 5" (10.16 and 12.7 cm) high chassis
• Network style UEF bay
• WECO mounting spaces
• Actual bay dimensions: 7' H x 26" W (2.14 m x 66.04 cm)
• Color: Putty
• 23" (58.42 cm) panel mounting
8/00 3
261
DSX-1 Skeleton Bays
Front Cross-
The front cross-connect network style skeleton bays are preassembled with a
Connect fuse panel and all cable and jumper management, but no panels, chassis or
modules. Miscellaneous and maintenance type equipment such as bridging
office repeaters, cross aisle panel, interbay patch panel, equipment shelf for
portable test set, communications panel, pencil storage drawer, etc., may be
substituted for a chassis.
In multiple lineup systems, the top two chassis positions in each bay should be
reserved for a cross aisle panel for extending cross-connects to other lineups.
26" 26"
BAY WIDTH BAY WIDTH
12" 15"
DEPTH DEPTH
4 8/00
261
DSX-1 Skeleton Bays
Front Cross- Skeleton bays are designed for use with 5" and 7" high
Connect DSX-1 chassis.
Note: See ADC Catalog 256, DSX-1 Digital Signal Cross-Connect Modules and Panels
for panel descriptions and choices.
Common Features
• Equipped with fuse panel, upper and lower horizontal jumper trough, vertical jumper rings on
front of bay
• Accommodates 5" and 7" (12.7 and 17.78 cm) high chassis
• Network style UEF bay
• WECO mounting spaces
• Actual bay dimensions: 7' H x 26" W (2.14 m x 66.04 cm)
• Color: Putty
• 23" (58.42 cm) panel mounting
8/00 5
261
DSX-3 Skeleton Bays
Rear Cross-
The rear cross-connect network style skeleton bays, are preassembled with a
Connect fuse panel and all cable and jumper management, but no chassis or modules.
Miscellaneous and maintenance type equipment such as bridging office repeat-
ers, cross aisle panel, interbay patch panel, equipment shelf for portable test set,
communications panel, pencil and storage drawers, etc., may be substituted for
a chassis.
In multiple lineup systems, the top chassis position in each bay should be
reserved for a cross aisle panel for extending cross-connects to other lineups.
3
3 Bay 4.5"
Bay 4.5" (incluWidth
(incluWidth jump ding
er rin
jump ding gs)
er rin
gs) 2 6
Rac "
2 6 k Wid
Rac " th
k Wid
th
7' 7'
Height Height
12" 15"
Depth Depth
6 8/00
261
DSX-3 Skeleton Bays
Rear Cross- DSX-3 Skeleton bays are designed for use with the
Connect following modular chassis:
DSX-4L 48 termination; 6" high chassis
DSX-4J 24 termination; 4" high chassis
DSX-4U 28 termination; 6" high chassis
DSX-4H 24 termination; 6" high chassis
NOTE: See ADC Catalog 272 and 274 DSX-3 Digital Signal Cross-Connect Front and
Rear Cross-Connect Products for chassis descriptions
Common Features
• Equipped with fuse panel, upper and lower horizontal jumper trough, vertical jumper rings on
rear of bay
• Bay dimensions: 7' H x 26" W (2.14 m x 66.04 cm)
• Network style UEF racks
• WECO mounting spaces
• Color: Putty
• 23" (58.42 cm) panel mounting
8/00 7
261
DSX-3 Skeleton Bays
8 8/00
261
DSX-3 Skeleton Bays
Front Cross-
The front cross-connect network style skeleton bays are preassembled with a
Connect fuse panel and all cable and jumper management, but no panels, chassis or
modules. Miscellaneous and maintenance type equipment such as bridging
office repeaters, cross aisle panel, interbay patch panel, equipment shelf for
portable test set, communications panel, pencil storage drawer, etc., may be
substituted for a chassis.
In multiple lineup systems, the top chassis position in each bay should be
reserved for a cross aisle panel for extending cross-connects to other lineups.
2
Bay 6" 2
Widt Bay 6"
h Widt
h
7' 7'
Height Height
12" 15"
Depth Depth
8/00 9
261
DSX-3 Skeleton Bays
Front Cross- Skeleton bays are designed for use with the following
Connect chassis:
DSX-4L 48 termination modular chassis
DSX-4F 24 termination modular chassis
DSX-4S 24 termination modular chassis
DSX-4B 24 termination modular chassis
DSX-4B 24 termination non-modular panel
NOTE: See ADC Catalog 272 and 274 DSX-3 Digital Signal Cross-Connect Front and
Rear Cross-Connect Products for chassis descriptions.
Common Features
• Equipped with fuse panel, upper and lower horizontal jumper trough, vertical jumper rings on
front of bay
• Network style UEF rack
• Actual bay dimensions: 7' H x 26" W (2.14 m x 66.04 cm)
• Color: Putty
• 23" (58.42 cm) panel mounting
10 8/00
261
Front Cross-Connect DSX-3 Skeleton Bays
8/00 11
261
Network Unequal Flange Earthquake Rack Framework
23" Framework
Earthquake
(To Zone 4)
A A
(HEIGHT) (HEIGHT)
(OPENING) 21.50"
(OPENING) 21.50"
(MTG HOLES) 22.31"
12.00" (MTG HOLES) 22.31" 12.00"
(FLANGE) 25.88"
(DEPTH) (FLANGE) 25.88" (DEPTH)
NOTE: Guard Box Cover and Bumper Rail are included with Network Racks.
12 8/00
261
Network Rack Accessories
*Kits include filler panel, guard box filler and all appropriate rack mounting hardware.
NOTE: Kits do not include AC raceway fillers. See page 16 for ordering information.
C B
(DEPTH) (WIDTH)
*Kits include filler panel, guard box filler and all appropriate rack mounting hardware.
NOTE: Kits do not include AC raceway fillers. See page 16 for ordering information.
Rear of rack filler spacer box is open to allow IN/OUT cables to pass through.
8/00 13
261
Network Rack Accessories
*Kits include filler panel, guard box filler and all appropriate rack mounting hardware.
Rack filler panels are hinged on the left side.
A
(HEIGHT)
NOTE: Kits do not include AC raceway fillers. See page 20 for catalog numbers.
*Kits include filler panel, guard box filler and all appropriate rack mounting hardware.
Rack filler panels are hinged on the left side.
NOTE: Kits do not include AC raceway fillers. See page 20 for catalog numbers.
Rack filler panels are hinged on the left side. Rear of rack filler spacer box is
open to allow cables to pass through.
14 8/00
261
Network Rack Accessories
DE B
Guard Box PT
H Ordering Information
Includes (5) bars for 7', 9' 2.5 12.0 79RSK-25DMTPW 79RSK-25DMTNB
and 11'6" racks
Includes (5) bars for 7', 9' 5.0 12.0 79RSK-50DMTPW 79RSK-50DMTNB
and 11'6" racks
Includes (5) bars for 7', 9' 10.0 12.0 79RSK-100DMTPW 79RSK-100DMTNB
and 11'6" racks
*Kits include spacer bars, guard box filler and all appropriate mounting hardware.
NOTE: Kits do not include AC raceway fillers. See page 16 for ordering information.
B
(DEPTH)
A
(WIDTH)
8/00 15
261
Network Rack Accessories
Raceways and
Raceway Fillers
For electrical wiring and
outlets for Network Rack
guard rails.
AC RACEWAY
Ordering Information
16 8/00
261
Network Rack Accessories
21.50"
22.31"
25.88"
8/00 17
261
Non-Network Unequal Flange Rack Framework
23 Inch
Earthquake
(To Zone 4)
A A
(HEIGHT) (HEIGHT)
6.00"
NOTE: Order Guard Box Cover and Guard Box (not included) on page 19.
NOTE: Order Guard Box Cover and Guard Box (not included) on page 19.
18 8/00
261
Non-Network Unequal Flange Rack Accessories
Cover Description
Catalog Number
(Gray)
Catalog Number
(Putty White)
.50"R 1.75"
4.34"
1.53"
45.00"
5.09"
2.00"
2.00"
.81"R
EARTHQUAKE CONFIGURATION FOOTPRINT
(SHOWN AT SCALE TIMES 2)
BASE
GUARD
BOX
8/00 19
261
Non-Network Unequal Flange Rack Accessories
Plate Kit* Width Height Rack Height Catalog Number Catalog Number
A (inches) B (Inches) (Ft.-in.) (Gray) (Putty)
Use with Rack Spacer
Box Kits 2.5 77.75 7'0" 7RFP-25 7RFP-25PW
2.5 101.75 9'0" 9RFP-25 9RFP-25PW
2.5 131.75 11'6" 11RFP-25 11RFP-25PW
5.0 77.75 7'0" 7RFP-5 7RFP-5PW
5.0 101.75 9'0" 9RFP-5 9RFP-5PW
5.0 131.75 11'6" 11RFP-5 PW116RFP-5
10.0 77.75 7'0" 7RFP-10 RAC-7C0236
10.0 101.75 9'0" 9RFP-10 RAC-9C0207
10.0 131.75 11'6" 11RFP-10 PW116RFP-10
*Kits include all applicable rack mounting hardware. Use only with non-
network unequal flange rack frameworks.
ADJACENT
RACKS
B
(HEIGHT)
(W
RACK
SPACERS
6"
A
(DEPTH) RACK
SPACER
A BOX
(WIDTH) Figure 1 Figure 2
B (WIDTH)
Plate Kit or with Rack Single only (Figure 1) 12.0 2.5 RSB-12 RSB-12PW
Spacer Kit Multiple boxes (Figure 2) 12.0 5.0 RSB-12A PWRSB-12A
Multiple boxes (Figure 2) 12.0 10.0 RACY013 RAC-0C0013
Single only (Figure 1) 15.0 2.5 RSB-15 RSB-15PW
Multiple boxes (Figure 2) 15.0 5.0 RSB-15A RAC-0C0014
Multiple boxes (Figure 2) 15.0 10.0 RAC-0C0020 RAC-0C0017
20 8/00
261
Non-Network Unequal Flange Rack Accessories
Use with Rack Spacer Quantity/ Width Catalog Number Catalog Number
Box Kits Description A (Inches) (Gray) (Putty)
Includes (4) bars for 7', 9' and 11'6" rack 0.0 11RSK-0 RAC-0C0246
RACKS REF
Includes (4) bars for 7', 9' and 11'6" rack 2.5 11RSK-25 RAC-0C0247
Includes (4) bars for 7', 9' and 11'6" rack 5.0 11RSK-5 RAC-0C0248
Includes (4) bars for 7', 9' and 11'6" rack 10.0 11RSK-10 RAC-0C0249
A
(WIDTH)
Non-Network A (HEIGHT)
Ordering Information
(OPENING) 21.50"
(MTG HOLES) 22.31"
(FLANGE) 25.94"
8/00 21
261
Network and Non-Network Rack Accessories
Universal End Height Depth Width Catalog Number Catalog Number Catalog Number
Guard Panels A (Ft.-In.) B (Inches) C (Inches) (Gray) (Putty) (Blue)
NOTE: 7" Toll End Guards to be used with Non-Network UEF Bays only
A A
(HEIGHT) (HEIGHT)
B C B C
(DEPTH) (WIDTH) (DEPTH) (WIDTH)
12" Universal End Guard Panel 7" Toll End Guard Panel
22 8/00
261
Network and Non-Network Rack Accessories
All kits may be used on Network and non-network racks and are rated to Earthquake
Zone 4 areas.
8/00 23
261
Channel Rack
3.0"
Framework 5.0"
2.0" 12" or 15"
4.25"
19 and 23 Inch or 6"
A 19" or 23"
(HEIGHT)
Guard Rail (front view)
7.0"
OPENING
MTG HOLES
C
CHANNEL
3.5" B
(DEPTH) D
Configuration 1
Bolted steel, double sided tapped mounting holes
Ordering Information
Panel Mounting Overall
Mounting Mounting Spaces Height Hole Width Opening Width Catalog
Size 1.75" (EIA) A (Ft.-In.) B (Inches) C (Inches) D (Inches) Number
24 8/00
261
Channel Rack
3.0"
Framework 2.0" 12" or 15"
4.25"
5.0"
19 and 23 Inch or 6"
A 19" or 23"
(HEIGHT) OPENING
MTG HOLES
C
B
CHANNEL Guard Rail (front view)
D
3.5"
12.5"
15.0"
Configuration 2
Bolted steel, double sided tapped mounting holes
Ordering Information
Panel Mounting Overall
Mounting Mounting Spaces Height Hole Width Opening Width Catalog
Size 1.75" (EIA) A (Ft.-In.) B (Inches) C (Inches) D (Inches) Number
8/00 25
261
Channel Rack Accessories
Color is gray.
A
(HEIGHT)
B
C (WIDTH)
(DEPTH)
2 3/8"
26 8/00
261
Channel Rack Accessories
8/00 27
261
Common Channel Rack Accessories
2.00 BC-2
L 3.00 BC-3
4.00 BC-4
5.00 BC-5
6.00 BC-6
7.00 BC-7
8.00 BC-8
Color is gray.
Bracket Kit* Bracket Height Mounting Rack Width Catalog Number Catalog Number Catalog Number
(Inches) Spaces Adapts (Putty) (Black) (Gray)
* Kit includes (2) brackets and all appropriate rack mounting hardware.
** This kit is used for all 19" x 1.75" equipment mounting in 23" x 2" racks.
28 8/00
261
Common Channel Rack Accessories
Note: all stand-off bracket kits include right and left bracket
and mounting screws
8/00 29
261
Common Channel Rack Accessories
19" or 23"
GBA-XX
.65"
.55"
GLK-1
GAK
30 8/00
261
Index
8/00 31
261
Index
32 8/00
261
Index
8/00 33
261
Index
RACY007 ..................................................................... 21
RACY013 ..................................................................... 20
RACY026 ..................................................................... 19
RBPH ........................................................................... 27
RCH ............................................................................. 27
RINST-DDP7-XX ......................................................... 23
RINST-DDP9-XX ......................................................... 23
RINST-DSX7-XX ......................................................... 23
RINST-DSX9-XX ......................................................... 23
RINST-DSXRFL-XX ........................................................ 23
RK5 .............................................................................. 18
RMSK-50 ..................................................................... 27
RMSK-51 ..................................................................... 27
RMSK-52 ..................................................................... 27
RSB-12 ........................................................................ 20
RSB-12A ...................................................................... 20
RSB-12PW .................................................................. 20
RSB-15 ........................................................................ 20
RSB-15A ...................................................................... 20
RSB-15PW .................................................................. 20
TEGP-7 ........................................................................... 22
TEGP-7NNB .................................................................... 22
TEGP-7NPW ............................................................... 22
TEGP-9 ........................................................................ 22
TEGP-9NNB ................................................................ 22
TEGP-9NPW ............................................................... 22
TEGP-11 ......................................................................... 22
TEGP-115NNB ................................................................ 22
TEGP-115NPW ............................................................... 22
UEF-7ER ..................................................................... 18
UEF-7ER1A ................................................................. 18
UEF-9ER1 ................................................................... 18
UEF-115ER1 ............................................................... 18
UEF-EBBR .................................................................. 19
UEF-EGB2 ................................................................... 19
UEF-EGB5 ................................................................... 19
UEF-EGBC .................................................................. 19
UEGP-7G .................................................................... 22
UEGP-7NB .................................................................. 22
UEGP-7PW ................................................................. 22
UEGP-9G .................................................................... 22
UEGP-9NBS ................................................................ 22
UEGP-9PW ................................................................. 22
UEGP-115G ................................................................ 22
UEGP-115NB .............................................................. 22
UEGP-115PW ............................................................. 22
34 8/00
261
From North America, Call Toll Free: 1-800-366-3891
Outside of North America: +1-952-938-8080
FAX: +1-952- 946-3292 ADC Telecommunications, Inc.
Web Site: http://www.adc.com P.O. Box 1101
For a complete listing of ADC's global sales office locations, please refer to our web site. Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications
without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an
important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents.
261 8/00 Revision © 1994, 1998, 2000 ADC Telecommunications, Inc. All Rights Reserved An Equal Opportunity Employer