Project name EDUCATIONAL BUILDINGS CONSTRUCTION IN RIYADH Project no.

RIYADH 111
Contractor name Al Bawani Co. Project Manager Eng / Shehzad khanzada
Consultant name AECOM Data Date 14-May-17
To the Engineer Report no. S13/701
School Name ABDULLAH IBNU-A'MER ELEMENTARY SCHOOL- BOYS School Code S13
Temperature Max : 34°C Min : 20°C Site Hand-Over Day 17-Feb-15
Weather Sunny Cloudy Rainy Humidity High Medium Low

Contractor's Manpower (including Subcontractors)* Plant/Equipment*

Status (Idle
Staff No. Direct Labor No Type Qty. Location
or Repair)
Projt. MGR. 1 Supervisor/Foreman 2 Excavator/ Poclain/ Excavator 0
Tech. Team 1 Precast Man 0 Shovel/ Loader/ Grader 0
Contract MGR. 1 Equipment Optr. 1 BOBCAT 1
Precast Manager 1 Carpenter 2 Dump Truck 0
Const. Manager 1 Welder 0 Roller/ Compactor 0
Project Control Team 1 Steelfixer 1 Portable Generator 0
QA/QC 1 E/M 7 Mobile Crane 0
Tech. Support 1 Mason 0 Tower Crane 0
Purch & Procurement 1 Painter Loabor 0 Pick up 0
Set. Manager 1 Plastering man 0 Water Tanker 1
Site Engineer 1 labor 8 Welding Machine 0
General Fork Lift
Safety/ HSE 1 0
Contractor JCB
Timekeeper 1 0
Electro Mechanical Engrs 1 Water Pump 2
Surveyor & Survayor Assistant 1 Bulldozer 0
Guard 2 Levelling Machine 0
Total station 0
Container 1
Water Tank 3
Portacabin 3
Temporary Genset 0

Sub Total/Main 17 21 4

Sub-contractors

Sub Total/Subcon 0 0 0

Grand Total 17 21 4

Activities and Tasks*


COMPLETED ACTIVITIES ON-GOING ACTIVITIES
Percentage
Type of Work Building Name Start Date Finish Date Type of Work Building Name Activity name Start Date Finish Date
Complete
Excavation Main Building - GF 8-Apr-15 18-Apr-15 Sub Structure Water Tank Bituminous Sheet Waterproofing for Water Tank 50.00% 29-Dec-16
Multi-purpose hall 13-Jul-16 18-Aug-16 Epoxy Ratengs of Waterproofing 95.00% 1-Mar-17
Electric Room 2-Jul-16 19-Jul-16 Boundary Wall Bituminous Waterproofing for Boundary Wall 90.00% 11-Jan-17
Canteen 7-Jun-16 24-Jul-16 Water Proofing Multi-purpose hall Foam Concrete 60.00% 4-Apr-17
Guard House 28-May-16 24-Jul-16 Gate Work Membrane Proofing 80.00% 2-May-17
Gate Work 25-Jul-16 2-Nov-16 Precast Boundary Wall Precast Concret Panels for Boundary Wall 90.00% 24-Dec-16
Site layout 17-Mar-15 24-Jul-16 Concrete Works Multi-purpose hall R.C Concrete for Stairs 85.00% 20-Mar-17
Water Tank 29-May-16 24-Jul-16 R.C Concrete for Ramp 85.00% 20-Mar-17
Boundary Wall 5-Jun-16 30-Jul-16 Plaster Cement Plastering 25.00% 1-May-17
Earth Works Site layout 1-Mar-15 24-Jul-16 Canteen Cement Plaster 50.00% 25-Mar-17
Sub Structure Main Building - GF 26-Aug-15 23-Jun-16 Guard House Cement Plaster 50.00% 26-Mar-17
Multi-purpose hall 25-Jul-16 7-Nov-16 Gate Work Cement Plaster 50.00% 26-Mar-17
Electric Room 27-Jul-16 25-Dec-16 Mechanical Main Building - GF Water Supply Pipes ( Cold & Hot ) & Testing 50.00% 14-Mar-17
Canteen 27-Jul-16 31-Oct-16 Drainage Pipes for Toilets & Testing 85.00% 15-Nov-16
Guard House 27-Jul-16 31-Oct-16 Floor Drain & Clean Out & Testing 80.00% 15-Nov-16
Gate Work 30-Jul-16 1-Jan-17 Electric Water Heaters & Testing 20.00% 8-May-17
Backfilling Main Building - GF 3-Jan-16 22-Jun-16 Pipe Fitting & Testing 60.00% 20-Feb-16
Multi-purpose hall 3-Sep-16 10-Nov-16 Fire Hose Cabinates 60.00% 20-Nov-16
Electric Room 23-Aug-16 28-Dec-16 HVAC Duct & Testing 90.00% 20-Jul-16
Canteen 8-Sep-16 26-Nov-16 Split Units & Testing 10.00% 8-May-17
Guard House 28-Aug-16 26-Nov-16 Main Building - FF Fire Extingushers 40.00% 6-Nov-16
Gate Work 3-Sep-16 7-Feb-17 Water Supply Pipes ( Cold & Hot ) & Testing 25.00% 19-Mar-17
Boundary Wall 4-Jan-17 11-Feb-17 Drainage Pipes for Toilets & Testing 85.00% 25-Sep-16
Slab On Grade Main Building - GF 22-Jun-16 9-Jul-16 Fire Hose Cabinates 60.00% 31-Oct-16
Multi-purpose hall 26-Sep-16 7-Nov-16 HVAC Duct & Testing 90.00% 23-Sep-16
Electric Room 15-Sep-16 1-Jan-17 Ventilation Fans & Testing 20.00% 31-Oct-16
Canteen 5-Oct-16 8-Dec-16 Split Units & Testing 40.00% 15-Oct-16
Guard House 20-Sep-16 8-Dec-16 Floor Drain & Clean Out & Testing 85.00% 22-Sep-16
Gate Work 25-Sep-16 10-Jan-17 Main Building - SF Split Units & Testing 25.00% 15-Oct-16
Precast Main Building - GF 24-Jan-16 29-Mar-16 HVAC Duct & Testing 60.00% 19-Sep-16
Main Building - FF 10-Feb-16 2-Apr-16 Drainage Pipes for Toilets & Testing 85.00% 20-Sep-16
Main Building - SF 10-Feb-16 9-Apr-16 Floor Drain & Clean Out & Testing 85.00% 22-Sep-16
Main Building - RF 15-Jun-16 14-Jul-16 Fire Extingushers 45.00% 7-Nov-16
Multi-purpose hall 28-Aug-16 12-Mar-17 Fire Hose Cabinates 45.00% 1-Nov-16
Electric Room 22-Sep-16 30-Jan-17 Main Building - RF Elevated Water Tanks & Testing 25.00% 22-Mar-17
Canteen 16-Oct-16 1-Feb-17 Roof Drain & Testing 85.00% 22-Sep-16
Guard House 1-Oct-16 22-Feb-17 Multi-purpose hall Fire Hose Cabinates 75.00% 27-Apr-17
Gate Work 12-Feb-17 28-Feb-17 Drainage Pipes for Toilets 90.00% 25-Oct-16
Block Work Main Building - GF 24-Jul-16 8-Aug-16 Roof Drain 80.00% 27-Apr-17
Main Building - FF 13-Jul-16 20-Sep-16 Split Units 10.00% 6-May-17
Main Building - SF 13-Jul-16 30-Oct-16 Electric Room Ventilation Fans 90.00% 26-Apr-17
Multi-purpose hall 19-Mar-17 29-Mar-17 Canteen Drainage Pipes for Toilets 80.00% 26-Oct-16
Canteen 5-Mar-17 7-Mar-17 Roof Drain 90.00% 19-Mar-17
Guard House 4-Mar-17 6-Mar-17 Split Unit 10.00% 6-May-17
Gate Work 5-Mar-17 7-Mar-17 Guard House Drainage Pipes for Toilets 90.00% 26-Oct-16
Water Tank 7-Mar-17 8-Mar-17 Roof Drain 70.00% 30-Apr-17
Plaster Main Building - GF 21-Nov-16 25-Feb-17 Windows Unit 10.00% 8-May-17
Main Building - FF 22-Aug-16 26-Feb-17 Gate Work Split Unit 10.00% 7-May-17

Page 1 of 2
Main Building - SF 15-Oct-16 25-Feb-17 Drainage Pipes for Toilets 80.00% 22-Feb-17
Water Tank 9-Mar-17 9-Mar-17 Roof Drain 90.00% 1-May-17
Doors Electric Room 7-Mar-17 9-Mar-17 Elevator Main Building - RF Install Steelwork Support For Elevator 50.00% 22-Mar-17
Windows Electric Room 7-Mar-17 9-Mar-17 Electric Traction Elevators 50.00% 15-Mar-17
Exposed Aggr. Main Building - RF 15-Jun-16 4-Jul-16 Electrical Main Building - GF Grounding System , UPS &Low-Voltage Electrical Power Conductors
80.00% and20-Sep-16
Cables
Electric Room 19-Mar-17 24-Mar-17 Lighting System Second Fix (Wires ) 90.00% 3-Sep-16
No R_Type Of Work Electric Room 7-Feb-17 26-Mar-17 Panelboards 70.00% 22-Feb-17
Wiring Devices Second Fix (Wires ) 92.00% 27-Apr-17
Fire Alarm Second Fix (Wires ) 92.00% 27-Apr-17
Data Communications System Second Fix (Wires ) 92.00% 27-Apr-17
IP Telephone System Second Fix (Wires ) 92.00% 27-Apr-17
Main Building - FF Lighting System Second Fix (Wires ) 92.00% 27-Apr-17
Panelboards 70.00% 22-Feb-17
Wiring Devices Second Fix (Wires ) 92.00% 27-Apr-17
Fire Alarm Second Fix (Wires ) 92.00% 27-Apr-17
Data Communications System Second Fix (Wires ) 92.00% 27-Apr-17
IP Telephone System Second Fix (Wires ) 92.00% 27-Apr-17
Grounding System , UPS &Low-Voltage Electrical Power Conductors
80.00% and21-Sep-16
Cables
Main Building - SF Lighting System Second Fix (Wires ) 92.00% 27-Apr-17
Panelboards 70.00% 22-Feb-17
Wiring Devices Second Fix (Wires ) 92.00% 27-Apr-17
Data Communications System Second Fix (Wires ) 92.00% 27-Apr-17
IP Telephone System Second Fix (Wires ) 92.00% 27-Apr-17
Fire Alarm Second Fix (Wires ) 92.00% 27-Apr-17
Grounding System , UPS &Low-Voltage Electrical Power Conductors
80.00% and14-Sep-16
Cables
Main Building - RF Panelboards 20.00% 15-Apr-17
Lighting Units (all building ) 50.00% 15-Apr-17
Multi-purpose hall Public Address System First Fix (Pipes ) 60.00% 5-May-17
IP Telephone System First Fix (Pipes ) 90.00% 29-Apr-17
Lighting System First Fix (Pipes ) 75.00% 29-Apr-17
Wiring Devices First Fix (Pipes ) 70.00% 30-Apr-17
Fire Alarm System First Fix (Pipes ) 35.00% 1-May-17
Canteen Panelboards 50.00% 15-Apr-17
Guard House Panelboards 50.00% 15-Apr-17
Gate Work Panelboards 50.00% 15-Apr-17
Doors Main Building - GF Hollow Metal Doors 50.00% 23-Mar-17
Main Building - FF Hollow Metal Doors 50.00% 28-Mar-17
Main Building - SF Hollow Metal Doors 50.00% 19-Mar-17
Windows Main Building - GF Aluminum Windows 50.00% 23-Mar-17
Main Building - FF Aluminum Windows 50.00% 23-Mar-17
Main Building - SF Aluminum Windows 53.00% 22-Mar-17
Space Frame Multi-purpose hall Install & Supply Space Frame 95.00% 22-Feb-17
Tiling Main Building - GF Granite Tiling 50.00% 20-Mar-17
Stairs Granite 75.00% 20-Mar-17
Porcelain Tiles 80.00% 21-Dec-16
Main Building - FF Granite Tiling 50.00% 22-Mar-17
Stairs Granite 70.00% 18-Mar-17
Porcelain Tiles 90.00% 9-Nov-16
Main Building - SF Granite Tiling 53.00% 22-Mar-17
Stairs Granite 70.00% 20-Mar-17
Porcelain Tiles 90.00% 21-Dec-16
Ceiling Main Building - GF Solid Gypsum Ceiling 80.00% 21-Dec-16
Main Building - FF Solid Gypsum Ceiling 90.00% 9-Nov-16
Main Building - SF Solid Gypsum Ceiling 90.00% 21-Dec-16
Paint Electric Room Final Coat Paint 40.00% 29-Mar-17
No R_Type Of Work Main Building - GF Porcelain Skirting 80.00% 21-Dec-16
Main Building - FF Granit Skirting 50.00% 20-Mar-17
Porcelain Skirting 90.00% 14-Nov-16
Main Building - SF Porcelain Skirting 90.00% 21-Dec-16

Materials delivered to Site*


Item Unit Qty. Approved submittal reference

Contractor's authorized signatory Engineer's authorized signatory


Name: Mohammad Anas Omar Al Hafi Name:
Signature: Signature:
Date: 14-May-17 Date: 14-May-17

* This form is to be used by the General Contractor to capture the above required information on a daily basis to report to the
Construction Supervisor (Engineer).

Page 2 of 2