IMPORTANT: Before you start with the installation of the product, read the attached IMPORTANT
SECURITY NOTES very carefully and follow all the herein given information very accurate!
Description:
This set contains: Raspberry PI B3+® board, 16 GB Micro SD card with preinstalled RaspBian®
Buster, enclosure for DIN rail and wall mounting, 3 native serial interfaces integrated: 1xRS232 and
2xRS485, hardware switching of RS485 direction, each serial interface has removable 3 pin terminal
clamp, integrated clock with battery backup, integrated power supply 12-48V= with two
removeable 2pin terminal clamps, Size (LxBxH):72x90x62mm, Weight:190g, Power supply:12-48V=,
Power consumption:15.0W, Housing:4MU, Mounting: DIN EN50022 rail or wall mounting,
Terminals: Terminal type RM5 , Cable cross section: max. 2.5 mm², max. 14AWG, Screw: M3,
Tightening torque: max. 0.5Nm, max. 4.43 Lb-in, Terminal type RM3.5, Cable cross section: max.
1.5 mm², max. 16AWG, Screw: M2, Tightening torque: max. 0.2Nm, max. 1.77 Lb-in, Certification:
CE, TARIC number:8538 90 91
Interfaces
The CODESYS device description does support the following components:
Visualization
CODESYS WebVisu, is included as full version in the delivery of the runtime package.
Fieldbus support
With the delivery of the Runtime Package the following fieldbuses are supported:
CODESYS CANopen Manager / Device
CODESYS EtherCAT Master
CODESYS EtherNet/IP Scanner / Adapter
CODESYS J1939
CODESYS Modbus TCP Master / Slave
CODESYS Modbus Serial Master / Slave
CODESYS PROFINET Controller / Device
Product options
Further products can be licensed for a fee:
CODESYS BACnet SL
CODESYS KNX SL
CODESYS Redundancy SL
CODESYS SoftMotion SL
CODESYS SoftMotion CNC+Robotics SL
Important hint:
Before you start with the installation and the initial setup of the device, you have to read
this document and the attached installation guide and the actual manual for the device
very carefully. You have to follow all the herein given information very accurate!
Only authorized and qualified personnel are allowed to install and setup the device!
The connection of the device must be done in de-energized state!
Do not perform any electrical work while the device is connected to power!
Disable and secure the system against any automatic restart or power on procedure!
The device must be operated with the defined voltage level!
Supply voltage jitters must not exceed the technical specifications and tolerances given in
the technical manuals for the product. If you do not obey this issue, the proper
performance of the device cannot be guaranteed. This can lead to fail functions of the
device and in worst case to a complete breakdown of the device!
You have to obey the current EMC regulations for wiring!
All signal, control and supply voltage cables must be wired in a way, that no inductive or
capacitive interference or any other severe electrical noise disturbance may interfere with
the device. Wrong wiring can lead to a malfunction of the device!
For signal or sensor cables you have to use shielded cables, to avoid damages through
induction!
You have to obey and to apply the current safety regulations given by the ÖVE, VDE, the
countries, their control authorities, the TÜV or the local energy supply company!
Obey country-specific laws and standards!
The device must be used for the intended purpose of the manufacturer!
No warranties or liabilities will be accepted for defects and damages resulting from
improper or incorrect usage of the device!
Subsequent damages, which results from faults of this device, are excluded from warranty
and liability!
Only the technical data, wiring diagrams and operation instructions, which are part to the
product shipment are valid!
The information on our homepage, in our datasheets, in our manuals, in our catalogues or
published by our partners can deviate from the product documentation and is not
necessarily always actual, due to constant improvement of our products for technical
progress!
In case of modification of our devices made by the user, all warranty and liability claims are
lost!
The installation has to fulfill the technical conditions and specifications (e.g. operating
temperatures, power supply, …) given in the devices documentation!
Operating our device close to equipment, which do not comply with EMC directives, can
influence the functionality of our device, leading to malfunction or in worst case to a
breakdown of our device!
Our devices must not be used for monitoring applications, which solely serve the purpose
of protecting persons against hazards or injury, or as an emergency stop switch for systems
or machinery, or for any other similar safety-relevant purposes!
Dimensions of the enclosures or enclosures accessories may show slight tolerances on the
specifications provided in these instructions!
Modifications of this documentation is not allowed!
In case of a complaint, only complete devices returned in original packing will be accepted