Lo 5 4210 217 12
Lo 5 4210 217 12
ORDER LO 5-4210-217-12
LI-00664G-12 15 MAY 1975 (Supersedes L05-4210-217-12 dated 6 APRIL 1973)
Intervals are based on normal hours of operation. Adjust Dry before lubricating.
to compensate for abnormal operations and severe
conditions. Lubricate points indicated by dotted arrow shafts on both
sides of equipment.
During inactive periods sufficient lubrication must be
performed for adequate preservation. * The times specified are the hours required to perform
311 services at the particular interval.
Clean fittings before lubricating.
A dotted circle indicates a drain below.
Clean parts with SOLVENT, dry-cleaning, Type II (SD-2).
NOTES:
10. HOSE REEL. The motor, drum shaft bearings, and
1. FOR OPERATION OF EQUIPMENT IN swivel connection, do not require lubrication.
PROTRACTED COLD TEMPERATURES BELOW Lubricate hose reel drive chain with cloth saturated
10°F. (-23°C). Remove lubricants prescribed in the with OE/HDO.
key for temperatures above 10°F.(-23°C).
Relubricate with lubricants specified in the key for 11. PRIMING PUMP MOTOR. Every 500 hours or
temperatures below -10°F. (-23°C). semiannually, whichever occurs first, lubricate the
priming pump motor. The oil can point is located on
2. OIL CAN POINTS. Every 250 hours or quarterly, top of motor shaft housing. Use only a few drops of
whichever occurs first, clean and lightly coat door oil, do not over lubricate.
hinges and locks, push-pull operating control rods,
throttle control, '"latches, springs, and pinion gear, 12. FIRE PUMP. Every 500 hours or semiannually,
and all exposed threads 'with OE/HDO. whichever occurs first, lubricate the 5 gear sector
racks with GAA. The racks are installed on the 3
3. LUBRICANTS. The following is a list of lubricants discharge and 2 suction valves.
with Military Symbols and applicable Specification
numbers. 13. BATTERY COMPARTMENT. Every 500 hours or
semiannually, whichever occurs first, lubricate the
GO MIL-L-2105 GOS sliding trays, channels of top cover, and battery
MIL-L-10324 terminals with GAA.
OE/HDO MIL-L-2104C OEA
MIL-L-46167 14. FIRE PUMP PACKING GLANDS. The stuffing boxes
GAA MIL-G-10924 (2 each) are designed to leak slightly during
operation to cool and lubricate the packing.
Acceptable leakage rates are 10 drops minimum to
4. PUMP COMPARTMENT PANEL. Remove bottom 60 drops maximum of water per minute at 150 psig
cover panel of pump compartment for access to PTO discharge pressure. To adjust packing glands, refer
propeller shaft universal and slip joints, transmission to TM 5-4210-217-12.
interlock cable, electric shift unit, priming pump
motor, and draining fire pump gear case. 15. PUMP GEAR CASE. Check oil level after each use.
Add if required. Note: Area of check located under
5. BEARING OUTBOARD (IMPELLER SHAFT). Every left operator's panel on chassis member.
250 hours of operation or quarterly, whichever occurs
first, lubricate until lubricant appears at relief fitting. 16. RADIATOR SHUTTER. Position control assembly
The relief fitting is located directly below the screw to full exposure and apply OE/HDO to surface.
lubrication fitting.
Copy of this Lubrication Order will remain with the
6. PTO PROPELLER SHAFT UNIVERSAL JOINTS. equipment at all times; instructions contained herein are
To prevent damage to journal seals, use relief fitting mandatory.
with grease gun.
By Order of the Secretaries of the Army and the Navy:
7. TANK, PRIMING PUMP. Check and fill the tank
every fifty hours or after each use, whichever occurs FRED C. WEYAND
first. When changing from one grade of oil to General, United States Army
another, remove the tank and empty through fill Official: Chief of Staff
opening.
VERNE L. BOWERS
8. TRANSFER VALVE.. During lubrication, operate Major General, United States Army
transfer valve control several times to distribute the The Adjutant General
grease. E.J. MILLER
Major General, U. S. Marine
9. ELECTRIC SHIFT UNIT. Routine oil changes are Corps Deputy Chief of Staff
not necessary. Changing the lubricant is required for Installations & Logistics
only for cold weather operation or when shift unit is
removed. To drain the shift unit remove cover plate. DISTRIBUTION:
During reassembly, install new cover plate gasket. Active Army: To be distributed In accordance with DA Form 12-
To fill shift unit, use pump type oil can. Fill until oil 25A, (qty rqr block no. 121) Operator maintenance requirements for Fire
flows from fill opening. Fighting.
Marine Corps: MARCORPS LIST: AO plus 7000161 (2)
LO5-4210-217-12
The Metric System and Equivalents