Information requirements

(air-to-air air conditioners)


Model(s): GMV-Y140WL/A-E
Outdoor side heat
exchanger of air air
conditioner
Indoor side heat exchanger
air
of air conditioner
Type compressor driven vapour compression
If applicable: driver of
electric motor
compressor
Item Symbol Value Unit Item Symbol Value Unit
Seasonal space
Rated cooling capacity Prated,c 14.00 kW cooling energy ηs,c 259.0 %
efficiency
Declared cooling capacity for part load at given outdoor Declared energy efficiency ratio for part load at given
temperatures Tj and indoor 27°/19 °C (dry/wet bulb) outdoor temperatures Tj
Tj = + 35 °C Pdc 14.00 kW Tj = + 35 °C EERd 2.86 -
Tj = + 30 °C Pdc 9.90 kW Tj = + 30 °C EERd 4.90 -
Tj = + 25 °C Pdc 6.50 kW Tj = + 25 °C EERd 9.10 -
Tj = + 20 °C Pdc 3.80 kW Tj = + 20 °C EERd 18.00 -
Degradation co-efficient
Cdc 0.25 — -
for air conditioners(*)
Power consumption in modes other than ‘active mode’
Crankcase heater
Off mode POFF 0.048 kW PCK 0.048 kW
mode
Thermostat-off mode PTO 0.022 kW Standby mode PSB 0.048 kW
Other items
Capacity control variable
For air-to-air air
Sound power level, outdoor LWA 75.00 dB
conditioner: air
If engine driven: Emissions mg/kWh fuel m3/
NOx(**) - flow rate, — 6300
of nitrogen oxides input GCV h
outdoor
kg CO2 eq
GWP of the refrigerant 2088 measured
(100 years)
Contact details: Name of manufacturer:
West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 GREE ELECTRIC APPLIANCES,INC. OF ZHUHAI
(*) If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25. (**)
From 26 September 2018. Where information relates to multi-split air conditioners, the test result and performance data
may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended
by the manufacturer or importer.
Information requirements
(heat pump)
Model(s): GMV-Y140WL/A-E
Outdoor side heat
air
exchanger of heat pump
Indoor side heat
air
exchanger of heat pump
Indication if the heater
is equipped with a no
supplementary heater
If applicable: driver of
electric motor
compressor
Parameters declared for Average climate condition
Item symbol value unit Item symbol value unit
Seasonal space heating
Rated heating capacity Prated,h 14.00 kW ηs,h 165.8 %
energy efficiency
Declared heating capacity for part load at indoor temperature Declared coefficient of performance for part load at given
20 °C and outdoor temperature Tj outdoor temperatures Tj
Tj = – 7 °C Pdh 9.60 kW Tj = – 7 °C COPd 2.86 -
Tj = + 2 °C Pdh 5.90 kW Tj = + 2 °C COPd 3.80 -
Tj = + 7 °C Pdh 3.80 kW Tj = + 7 °C COPd 6.30 -
Tj = + 12 °C Pdh 2.62 kW Tj = + 12 °C COPd 7.00 -
Tbiv = bivalent
Pdh 9.60 kW Tbiv = bivalent temperature COPd 2.86 -
temperature
TOL = operation limit Pdh 11.00 kW TOL = operation limit COPd 2.20 -
Tj = – 15 °C (if TOL < – Tj = – 15 °C (if TOL < –
Pdh - kW COPd - -
20 °C) 20 °C)
Operation limit
Bivalent temperature Tbiv -7.00 °C Tol -10.00 °C
temperature
Degradation co-efficient
Cdh 0.25 —
heat pumps(**)
Power consumption in modes other than ‘active mode’ Supplementary heater
Back-up heating capacity
Off mode POFF 0.048 kW elbu 0 kW
(*)
Thermostat-off mode PTO 0.053 kW Type of energy input Electric
Crankcase heater mode PCK 0.048 kW Standby mode PSB 0.048 kW
Other items
Capacity control variable
air flow rate, outdoor
Sound power level, — 6300 m3/h
LWA -/75.00 dB measured
indoor/outdoor measured
Emissions of nitrogen mg/kWh
NOx(***) - Rated brine or water flow
oxides (if applicable) input GCV
rate, outdoor side heat — - m3/h
kg CO2 eq
GWP of the refrigerant 2088 exchanger
(100 years)
Contact details: Name of manufacturer:
West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 GREE ELECTRIC APPLIANCES,INC. OF ZHUHAI
(*)
(**) If Cdh is not determined by measurement then the default degradation coefficient of heat pumps shall be 0,25.
(***) From 26 September 2018.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the
performance of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.