db-installation-guide-5-edition-rev-3
db-installation-guide-5-edition-rev-3
dB FLANGE DIMENSIONS (mm) Dispose of Transducer and cable in accordance with regional
environment regulations for electronic equipment e.g. WEEE
regulations apply within the EU to Directive 2012/19/EU
SPECIFICATIONS
There are two different versions:
One certified to Exia IIC T6 (Sira 02ATEX2103X) for use in zone 0,
1, 2, 20, 21 & 22 applications (safety barrier required), and another
certified to Exmb IIC T6, Exmb IIIC T85°C Db (Sira 02ATEX5104X Range in Blanking Operating Housing Housing
Model
and IECEx SIR 18.0037X ) suitable for use in zones 1, 2, 21 & 22 metres distance frequency dia. (mm) height
(no barriers required). 180
dBMach 3 2.5 0m 125kHz 215
The ‘X’ in the certification No.’s indicates the following special (sunshield)
dB3 3 0.125m 125kHz 78 115
conditions apply:
dB6 6 0.3m 75kHz 86 104
Exia & Exmb versions – Due to the plastic housing it is possible an dB10 10 0.3m 50kHz 86 104
electrostatic discharge may be generated, therefore when used for dB15 15 0.6m 40kHz 86 122
applications that specifically require group II category 1, do not dB25 25 0.6m 30kHz 105 142
install in conditions that are conducive to the build up of dB40 40 1.2m 20kHz 205 223
electrostatic charge. Additionally, clean only with a damp cloth.
Exmb version – This version must be supplied from apparatus that Process Connection: 1” BSP or NPT
provides protection from prospective short circuit currents up to Operating Temperature: -40 to +90°C (dB3/dBmach3 -30 to +90°C)
4000A. The Ultra and Blackbox units are provided with these fuses. In hazardous area -40 to +75° C (dB3/dBmach3 -30 to +75°C) Once the transducer is installed in position the cable can be routed
The dB transducers must be routinely inspected to avoid the build- Ingress Protection: IP68. back to the PULSAR ultra instrumentation and wired up. If the integral
up of a dust layer when installed in Zones 20, 21 & 22. cable is too short an extension cable and junction box may be used,
see figure 5. The cable can be extended up to 500 m.