0% found this document useful (0 votes)
16 views13 pages

E5cn-H Ds e 4 12 csm1376

Uploaded by

Petar Pavlov
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views13 pages

E5cn-H Ds e 4 12 csm1376

Uploaded by

Petar Pavlov
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

Advanced Digital Temperature Controller

E5CN-H (48 x 48 mm)


CSM_E5CN-H_DS_E_4_12

A New High-performance Controller: High Resolution, High Speed, and


High Input Accuracy.
Logic Operations and Preventive
Maintenance Function.
• High-resolution display with 5 digits/0.01°C display in a compact
Controller (48 x 48 mm).
• High-speed sampling cycle of 60 ms.
• High Accuracy
Thermocouple/Pt input: ±0.1% of PV
Analog input: ±0.1% FS
• Universal inputs on all models (thermocouple, PT, or analog
48 × 48 mm
input) to handle various sensors with one Controller. E5CN-H
• A PV/SV-status display function can be set to automatically alternate For the most recent information on models that have been certified for
between displaying the status of the Temperature Controller (auto/ safety standards, refer to your OMRON website.

manual, RUN/STOP, and alarms) and the PV or SV.


• Flexible contact outputs with logic operations (AND, OR, and Refer to Safety Precautions for E5@N/E5@N-H.
delays) set from the Support Software (CX-Thermo Ver. 4.0) Refer to Operation for E5@N/ E5@N-H for operating
• Preventive maintenance for relays in the Temperature procedures.
Controller using a Control Output ON/OFF Counter.

Main I/O Functions

Event Inputs
E5CN-H
• None
• Two
2-level Display: PV and SV 5-digit Display with high resolution of 0.01°C

Universal Sensor Inputs


• Auto/manual switching
• Universal thermocouple/Pt/analog
Auxiliary Outputs • Temperature Controller status display
(current/voltage) inputs.
• Two • Simple program function
Control Output 2 • Logic operations
Indication Accuracy
• None • Control output ON/OFF count alarm
• Thermocouple/Pt input: ±0.1% of PV
• Voltage output • PV change rate alarm
• Analog input: ±0.1% FS
(for driving SSR) • Models also available with RS-485 or
RS-232C communications
Sampling Period
Control Output 1
• 60 ms
• Relay output
• Voltage output (for driving SSR)
• Current output
• Linear voltage output

This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
and other information required for operation before attempting to use the product.
E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157)
E5CN-H/E5AN-H/E5EN-H Digital Controllers Communications Manual Advanced Type (Cat. No. H159)

1
E5CN-H
Lineup
1 control output 2 auxiliary outputs
E5CN-H
Terminal block Fully universal input
Advanced Type
2 control outputs 2 auxiliary outputs

Note: Models with one control output and models with two control outputs can be used for heating/cooling control.

Model Number Structure


Model Number Legend
Controllers Option Units

E5CN-@@@M@-@-500 E53-@@@@
1 2 3 4 5 6 7 1 2 3 4
1. Type 1. Applicable Controller
H: Advanced CN: E5CN-H or E5CN
2. Control Output 1 2. Function 1
R: Relay output Blank: None
Q: Voltage output (for driving SSR) Q: Control output 2 (voltage output for driving SSR)
C: Current output P: Power supply for sensor
V: Linear voltage output C: Current output
3. Auxiliary Outputs 3. Function 2
2: Two outputs Blank: None
H: Heater burnout/SSR failure/Heater overcurrent detection (CT1)
4. Option 1
HH: Heater burnout/SSR failure/Heater overcurrent detection
M: Option Unit can be mounted.
(CT2)
5. Power Supply Voltage B: Two event inputs
Blank: 100 to 240 VAC 03: RS-485 communications
D: 24 VAC/VDC H03: Heater burnout/SSR failure/Heater overcurrent detection
(CT1) + RS-485 communications
6. Case Color HB: Heater burnout/SSR failure/Heater overcurrent detection
Blank: Black (CT1) + Two event inputs
W: Silver HH03: Heater burnout/SSR failure/Heater overcurrent detection
7. Terminal Cover (CT2) + RS-485 communications
-500: With terminal cover H01: Heater burnout/SSR failure/Heater overcurrent detection
(CT1)/RS-232C communications
F: Transfer output
BF: Two event inputs/Transfer output
4. Version
N2: Available only to models released after January 2008
Note: Not all combinations of function 1 and function 2 specifications are possible for Option Units (E53-@@@@).

2
E5CN-H
Ordering Information
Controllers
Size Case Color Power supply voltage Auxiliary output Control output 1 Model
Relay output E5CN-HR2M-500
Voltage output (for driving SSR) E5CN-HQ2M-500
100 to 240 VAC 2
Current output E5CN-HC2M-500
Linear voltage output E5CN-HV2M-500
Black
Relay output E5CN-HR2MD-500
Voltage output (for driving SSR) E5CN-HQ2MD-500
1/16 DIN 24 VAC/VDC 2
Current output E5CN-HC2MD-500
48 × 48 × 78
(W × H × D) Linear voltage output E5CN-HV2MD-500
Relay output E5CN-HR2M-W-500
100 to 240 VAC 2 Voltage output (for driving SSR) E5CN-HQ2M-W-500
Current output E5CN-HC2M-W-500
Silver
Relay output E5CN-HR2MD-W-500
24 VAC/VDC 2 Voltage output (for driving SSR) E5CN-HQ2MD-W-500
Current output E5CN-HC2MD-W-500

Option Units
One of the following Option Units can be mounted to provide the E5CN with additional functions.
Functions Model
Communications 3-phase heater burnout/SSR failure/
E53-CNHH03N2
RS-485 Heater overcurrent detection
Heater burnout/SSR failure/
Event inputs E53-CNHBN2
Heater overcurrent detection
Communications Control output 2
E53-CNQ03N2
RS-485 (Voltage for driving SSR)
Communications Heater burnout/SSR failure/
E53-CNH03N2
RS-485 Heater overcurrent detection
Communications
E53-CN03N2
RS-485
Event inputs E53-CNBN2
Heater burnout/SSR failure/ Control output 2
E53-CNQHN2
Heater overcurrent detection (Voltage for driving SSR)
3-phase heater burnout/SSR failure/ Control output 2
E53-CNQHHN2
Heater overcurrent detection (Voltage for driving SSR)
Control output 2
Event inputs E53-CNQBN2
(Voltage for driving SSR)
Control output 2
Transfer Output E53-CNQFN2
(Voltage for driving SSR)
Event inputs Transfer Output E53-CNBFN2
Communications Control output 2
E53-CNQ01N2
RS-232C (Voltage for driving SSR)
Communications
E53-CN01N2
RS-232C
Communications Heater burnout/SSR failure/
E53-CNH01N2
RS-232C Heater overcurrent detection
Note: These Option Units are applicable only to models released after January 2008.

Accessories (Order Separately)


USB-Serial Conversion Cable Adapter
Model Connectable models Model
E58-CIFQ1 Terminal type Y92F-45
Note: Use this Adapter when the panel has been previously prepared for the E5B@.
Terminal Cover
Model
DIN Track Mounting Adapter
E53-COV17 Model
Note: 1. The Terminal Cover comes with the E5CN-@@@-500 Y92F-52
models.
2. The E53-COV10 cannot be used. Front cover
Type Model
Waterproof Packing Hard Front Cover Y92A-48B
Model Soft Front Cover Y92A-48D
Y92S-P8
Note: Waterproof Packing is included with the controller only for CX-Thermo Support Software
models with terminal blocks. Model
EST2-2C-MV4
Current Transformers (CTs)
Hole diameter Model Mounting Adapter
5.8 dia. E54-CT1
Model
12.0 dia. E54-CT3 Y92F-49
Note: This Mounting Adapter is provided with the Digital Temperature Controller.

3
E5CN-H
Specifications
Ratings
No D in model number: 100 to 240 VAC, 50/60 Hz
Power supply voltage
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range 85% to 110% of rated supply voltage
100 to 240 VAC: 8.5 VA (max.) (E5CN-HR2 at 100 VAC: 3.0 VA)
Power consumption
24 VAC/VDC: 5.5 VA (24 VAC)/3.5 W (24 VDC) (max.) (E5CN-HR2D at 24 VAC: 2.7 VA)
Any of the following can be selected (i.e., fully universal input).
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Sensor input Platinum resistance thermometer: Pt100 or JPt100
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedance Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB-N.)
Control method ON/OFF control or 2-PID control (with auto-tuning)
Relay output SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
Voltage output
Output voltage: 12 VDC ±15% (PNP), max. load current: 21 mA, with short-circuit protection circuit
Control (for driving SSR)
output Current output 4 to 20 mA DC/0 to 20 mA DC, load: 600 Ω max., resolution: approx. 10,000 *
Linear voltage
0 to 10 VDC (load: 1 kΩ min.), Resolution: Approx. 10,000
output
Number of outputs 2 max.
Auxiliary
output Output Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable
specifications load: 5 V, 10 mA
Number of outputs 2
Event External contact Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
input input Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
specifications Current flow: Approx. 7 mA per contact
Number of
8 max. (Combinations can be made using work bits.)
operations
• Logic operation: Any of the following four patterns can be selected. The input status may be inverted.
(A and B) or (C and D), (A or C) and (B or D), A or B or C or D, A and B and C and D (A, B,
Logic C, and D are four inputs.)
Operations
opera- • Delay: ON delay or OFF delay for the results of the logic operation given above.
tions Setting time: 0 to 9999 s or 0 to 9999 min
• Output inversion: Possible
Outputs One work bit per operation
Work bit Any of the following can be assigned to up to eight work bits (logic operation results): Event input operations,
assignments auxiliary outputs, or control outputs.
Number of outputs 1 max.
Transfer
outputs Output Current output: 4 to 20 mA DC, Load: 600 Ω max., Resolution at 4 to 20 mA: Approx. 10,000
specifications
RSP input Not supported
Setting method Digital setting using front panel keys
11-segment digital display and individual indicators (7-segments displays also possible)
Indication method
Character height: PV: 11 mm, SV: 6.5 mm
Supported (number of banks: 8)
Bank switching
Local SP, alarm settings, PID sets (PID constants, MV upper limit, MV lower limit, etc.)
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout
detection, 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop,
Other functions
protection functions, control output ON/OFF counter, extraction of square root, MV change rate limit, PV/SV
status display, logic operations, automatic cooling coefficient adjustment
Ambient operating
−10 to 55°C (with no condensation or icing), for 3-year warranty: −10 to 50°C
temperature
Ambient operating humidity 25% to 85%
Storage temperature −25 to 65°C (with no condensation or icing)
* For models with current outputs, control output 1 can be used as a transfer output.

4
E5CN-H

Input Ranges
Thermocouple/Platinum Resistance Thermometer/Analog Input (Fully Universal Inputs)
Platinum resistance Analog
Input type Thermocouple
thermometer input
4 to 0 to 1 to 0 to 0 to
Name Pt100 JPt100 K J T E L U N R S B W PL II 20 mA 20 mA 5V 5 V 10 V
2300.0
2300
1800.0
1800
1700.01700.0
1700
1600
1500
1400
1300.0 1300.0 1300.0
1300
Temperature range (°C)

1200
1100
Usable in the following
1000 ranges by scaling:
850.0 850.0 850.0
900 −19999 to 32400,
800 −1999.9 to 3240.0,
700 −199.99 to 324.00, or
600
600.0 −19.999 to 32.400
500.0 500.0 500.0
500
400.0 400.0 400.0 400.0 400.0
400
300
200.00 200.00 200.00 200.00
200
100.0 100.0
100
100.0
0
0.0 0.0 0.0 0.0 0.0 0.0
−100
−50.00 −20.0 −50.00−100.0 −20.0 −50.00 −50.00 −100.0
−200
−200.0−199.9 −199.9 −200.0 −200.0−199.9 −200.0 −200.0−199.9−200.0

Setting
number 0 1 2 24 3 4 5 6 21 7 8 22 9 10 23 11 12 13 14 15 16 17 18 19 20 25 26 27 28 29

Shaded settings are the default settings.


The applicable standards for the input types are as follows:
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 584-1 JPt100: JIS C 1604-1989, JIS C 1606-1989
L: Fe-CuNi, DIN 43710-1985 Pt100: JIS C 1604-1997, IEC 751
U: Cu-CuNi, DIN 43710-1985 PL II: According to Platinel II electromotive force charts from BASF (previously
W: W5Re/W26Re, ASTM E988-1990 Engelhard)

5
E5CN-H

Alarm Outputs
Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit.
Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm 1 will be an OR output of the alarm selected from the
following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent. To output only a heater burnout alarm, SSR
failure alarm, and heater overcurrent alarm for alarm 1, set the alarm type to 0 (i.e., no alarm function).

Alarm output operation


Set value Alarm type When alarm value When alarm value Description of function
X is positive X is negative
0 Alarm function OFF Output OFF No alarm
L H
Set the deviation in the set point by setting the alarm
1 *1 Upper- and lower-limit
ON
*2
OFF
SP upper limit (H) and alarm lower limit (L).
ON
X
ON
X
Set the upward deviation in the set point by setting
2 Upper-limit OFF
SP
OFF
SP the alarm value (X).
ON
X
ON
X
Set the downward deviation in the set point by setting
3 Lower-limit OFF
SP
OFF
SP the alarm value (X).
L H
Set the deviation in the set point by setting the alarm
4 *1 *3
ON
Upper- and lower-limit range OFF
SP upper limit (H) and alarm lower limit (L).
L H
ON
Upper- and lower-limit with A standby sequence is added to the upper- and
5 *1 OFF *4
standby sequence SP
lower-limit alarm (1). *6
*5
ON
X
ON
X
A standby sequence is added to the upper-limit alarm
6 Upper-limit with standby sequence OFF
SP
OFF
SP (2). *6
ON
X
ON
X
A standby sequence is added to the lower-limit alarm
7 Lower-limit with standby sequence OFF
SP
OFF
SP (3). *6
ON
X
ON
X
The alarm will turn ON if the process value is larger
8 Absolute-value upper-limit OFF
0
OFF
0 than the alarm value (X) regardless of the set point.
ON
X
ON
X
The alarm will turn ON if the process value is smaller
9 Absolute-value lower-limit OFF
0
OFF
0 than the alarm value (X) regardless of the set point.
Absolute-value upper-limit with ON
X
ON
X
A standby sequence is added to the absolute-value
10
standby sequence OFF
0
OFF
0 upper-limit alarm (8). *6
Absolute-value lower-limit with ON
X
ON
X
A standby sequence is added to the absolute-value
11
standby sequence OFF
0
OFF
0 lower-limit alarm (9). *6
12 LBA (alarm 1 type only) --- *7
13 PV change rate alarm --- *8
*1. With set values 1, 4 and 5, the upper and lower limit values can *5. Set value: 5, Upper- and lower-limit with standby sequence
be set independently for each alarm type, and are expressed as Always OFF when the upper-limit and lower-limit hysteresis
“L” and “H.” overlaps.
*2. Set value: 1, Upper- and lower-limit alarm *6. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature
Case 1 Case 2 Case 3 (Always ON)
Controllers User's Manual Basic Type (Cat. No. H156) for
H < 0, L < 0 information on the operation of the standby sequence.
L H SP SP L H H SP L *7. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature
H < 0, L > 0 Controllers User's Manual Basic Type (Cat. No. H156) for
H < 0, L > 0 H > 0, L < 0
⏐H⏐ < ⏐L⏐ ⏐H⏐ > ⏐L⏐
H L SP ⏐H⏐ ≥ ⏐L⏐ information on the loop burnout alarm (LBA).
H > 0, L < 0 *8. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature
SP H L ⏐H⏐ ≤ ⏐L⏐ Controllers User's Manual Basic Type (Cat. No. H156) for
*3. Set value: 4, Upper- and lower-limit range information on the PV change rate alarm.

Case 1 Case 2 Case 3 (Always OFF)


H < 0, L < 0
L H SP SP L H H SP L
H < 0, L > 0 H > 0, L < 0 H < 0, L > 0
⏐H⏐ < ⏐L⏐ ⏐H⏐ > ⏐L⏐ H L SP ⏐H⏐ ≥ ⏐L⏐

H > 0, L < 0
SP H L ⏐H⏐ ≤ ⏐L⏐
*4. Set value: 5, Upper- and lower-limit with standby sequence
For Upper- and Lower-Limit Alarm Described Above
• Case 1 and 2
Always OFF when the upper-limit and lower-limit hysteresis
overlaps.
• Case 3: Always OFF

6
E5CN-H

Characteristics
Thermocouple: (±0.1% of indicated value or ±1°C, whichever is greater) ±1 digit max. *1
Platinum resistance thermometer: (±0.1% of indicated value or ±0.5°C, whichever is greater) ±1 digit max.
Indication accuracy
Analog input: ±0.1% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Transfer output accuracy ±0.3% FS max.
Influence of temperature
*2 Thermocouple input (R, S, B, W, PLII): (±1% of PV or ±10°C, whichever is greater) ±1 digit max.
Other thermocouple input: (±1% of PV or ±4°C, whichever is greater) ±1 digit max. *3
Influence of voltage *2
Platinum resistance thermometer: (±1% of PV or ±2°C, whichever is greater) ±1 digit max.
Influence of EMS. Analog input: (±1%FS) ±1 digit max.
(at EN 61326-1)
Input sampling period 60 ms
Temperature input: 0.1 to 3240.0°C or °F (in units of 0.1°C or °F)
Hysteresis
Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)
Temperature input: 0.1 to 3240.0°C or °F (in units of 0.1 °C or °F)
Proportional band (P)
Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)
Integral time (I) 0.0 to 3240.0 s (in units of 0.1 s)
Derivative time (D) 0.0 to 3240.0 s (in units of 0.1 s)
Control period 0.5, 1 to 99 s (in units of 1 s)
Manual reset value 0.0 to 100.0% (in units of 0.1%)
Alarm setting range −19999 to 32400 (decimal point position depends on input type)
Affect of signal source Thermocouple: 0.1°C/Ω max. (100 Ω max.)
resistance Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.)
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge)
Vibration Malfunction 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
resistance Destruction 10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions
Shock Malfunction 100 m/s2, 3 times each in X, Y, and Z directions
resistance Destruction 300 m/s2, 3 times each in X, Y, and Z directions
Weight Controller: Approx. 150 g, Mounting Bracket: Approx. 10 g
Degree of protection Front panel: IP66, Rear case: IP20, Terminals: IP00
Memory protection Non-volatile memory (number of writes: 1,000,000 times)
Setup Tool CX-Thermo version 4.0 or higher
Provided on the bottom of the E5CN-H. Use this port to connect a computer to the E5CN-H.
Setup Tool port
An E58-CIFQ1 USB-Serial Conversion Cable is required to connect the computer to the E5CN-H. *4
Approved
UL 61010-1, CSA C22.2 No. 1010-1
standards
Standards
Conformed
EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II, Lloyd's standards *5
standards
EMI: EN 61326-1 *6
Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A
Noise Terminal Voltage: EN 55011 Group 1, class A
EMS: EN 61326-1 *6
ESD Immunity: EN 61000-4-2
EMC Electromagnetic Field Immunity: EN 61000-4-3
Burst Noise Immunity: EN 61000-4-4
Conducted Disturbance Immunity: EN 61000-4-6
Surge Immunity: EN 61000-4-5
Power Frequency Magnetic Field Immunity: EN 61000-4-8
Voltage Dip/Interrupting Immunity: EN 61000-4-11
*1. The indication accuracy of K thermocouples in the −200 to 1300°C range, T and N thermocouples at a temperature of −100°C max., and U
and L thermocouples at any temperatures is ±2°C ±1 digit max. The indication accuracy of the B thermocouple at a temperature of 400°C max.
is not specified. The indication accuracy of B thermocouples in the 400 to 800°C range is ±3°C max. The indication accuracy of the R and S
thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W thermocouples is ±0.3 of PV or ±3°C,
whichever is greater, ±1 digit max. The indication accuracy of PL II thermocouples is ±0.3 of PV or ±2°C, whichever is greater, ±1 digit max.
*2. Ambient temperature: −10°C to 23°C to 55°C, Voltage range: −15% to 10% of rated voltage
*3. K thermocouple at −100°C max.: ±10°C max.
*4. External communications (RS-232C or RS-485) and cable communications for the Setup Tool can be used at the same time.
*5. Refer to information on maritime standards in Safety Precautions for E5@N/E5@N-H for compliance with Lloyd's Standards.
*6. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)

7
E5CN-H

USB-Serial Conversion Cable Current Transformer (Order Separately)


Applicable OS Windows XP/Vista/7/8/8.1/10 Ratings
Applicable software CX-Thermo version 4 or higher Dielectric strength 1,000 VAC for 1 min
E5AN/E5EN/E5CN/E5CN-U/ Vibration resistance 50 Hz, 98 m/s2
Applicable models
E5AN-H/E5EN-H/E5CN-H
E54-CT1: Approx. 11.5 g,
Weight
USB interface standard Conforms to USB Specification 1.1. E54-CT3: Approx. 50 g
DTE speed 38400 bps Armatures (2)
Accessories (E54-CT3 only) Plugs (2)
Computer: USB (type A plug)
Connector specifications Temperature Controller: Setup Tool
port (on bottom of Controller) Heater Burnout Alarms, SSR Failure
Power supply
Bus power (Supplied from USB Alarms, and Heater Overcurrent Alarms
host controller.)
Models with detection for single-
Power supply voltage 5 VDC phase heaters: One input
CT input (for heater
Current consumption 70 mA Models with detection for single-
current detection)
phase or three-phase heaters: Two
Ambient operating 0 to 55°C (with no condensation or
inputs
temperature icing)
Maximum heater current 50 A AC
Ambient operating humidity 10% to 80%
Input current indication
−20 to 60°C (with no condensation ±5% FS ±1 digit max.
Storage temperature accuracy
or icing)
Heater burnout alarm 0.1 to 49.9 A (in units of 0.1 A)
Storage humidity 10% to 80%
setting range *1 Minimum detection ON time: 100 ms
Altitude 2,000 m max.
SSR failure alarm setting 0.1 to 49.9 A (in units of 0.1 A)
Weight Approx. 100 g range *2 Minimum detection OFF time: 100 ms
Note: A driver must be installed in the personal computer. Refer to Heater overcurrent alarm 0.1 to 49.9 A (in units of 0.1 A)
installation information in the operation manual for the setting range *3 Minimum detection ON time: 100 ms
Conversion Cable.
*1. For heater burnout alarms, the heater current will be measured
when the control output is ON, and the output assigned to the
Communications Specifications alarm 1 function will turn ON if the heater current is lower than the
set value (i.e., heater burnout detection current value).
Transmission line RS-485: Multipoint
*2. For SSR failure alarms, the heater current will be measured when
connection method RS-232C: Point-to-point
the control output is OFF, and the output assigned to the alarm 1
Communications RS-485 (two-wire, half duplex)/RS-232C function will turn ON if the heater current is higher than the set
Synchronization value (i.e., SSR failure detection current value).
Start-stop synchronization *3. For heater overcurrent alarms, the heater current will be
method
measured when the control output is ON, and the output assigned
Protocol CompoWay/F, SYSWAY, or Modbus to the alarm 1 function will turn ON if the heater current is higher
1200, 2400, 4800, 9600, 19200, 38400, or than the set value (i.e., heater overcurrent detection current
Baud rate
57600 bps value).
ASCII (CompoWay/F, SYSWAY)
Transmission code
RTU (Modbus) Electrical Life Expectancy Curve for
Data bit length * 7 or 8 bits Relays (Reference Values)
Stop bit length * 1 or 2 bits
Life (× 104 operations)

500
Vertical parity (none, even, odd) 300
Frame check sequence (FCS) with SYSWAY
Error detection
Block check character (BCC) with
CompoWay/F or CRC-16 Modbus 100

Flow control None 50


Interface RS-485, RS-232C 30

Retry function None


Communications 10
217 bytes
buffer
5
E5CN-H
Communications 0 to 99 ms 250 VAC, 30 VDC
3
response wait time Default: 20 ms (resistive load)
cosφ = 1
* The baud rate, data bit length, stop bit length, and vertical parity can
1
be individually set using the Communications Setting Level. 0 1 2 3 4 5 6
Switching current (A)

8
E5CN-H
External Connections
• A voltage output (control output, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple,
do not connect any of the control output terminals to ground. If the control output terminals are connected to ground, errors will occur in the
measured temperature values as a result of leakage current.

Controllers
The Temperature Controller is set for a K-type
thermocouple (input type = 5) by default. An input error
Control output 1
(s.err) will occur if the input type setting does not agree
Relay output with the temperature sensor. Check the input type.
250 VAC, 3 A
(resistive load) Auxiliary outputs Auxiliary outputs (relay outputs)
(relay outputs) 250 VAC, 3 A
Voltage output 1 11 6 (resistive load)
(for driving SSR) Control output 1 Auxiliary output 2
12 VDC, 21 mA 2 12 7 A heater burnout alarm, SSR
Linear voltage output Auxiliary output 1 failure, heater overcurrent alarm,
DO NOT DO NOT A or input alarm is sent to the
0 to 10 VDC USE USE 3 13 8
Load 1 k: min. output to which the alarm 1
mA B
Current output 4 14 9 function is assigned.
0 to 20 mA DC V Input power supply
DO NOT B x 100 to 240 VAC
4 to 20 mA DC 5 15 10
USE x 24 VAC/VDC (no polarity)
Load 600 : max.

Option Units
E53-CNBN2 E53-CNQBN2 E53-CNHBN2 E53-CNBFN2
Event Inputs Event Inputs and Event Inputs Event Inputs and
Control Output 2 and CT Transfer Output

11 11 11 11

EV1
12 EV1
12 EV1
12 12
EV1
13 13 13 13
EV2 EV2 EV2 EV2
DO NOT 14 14 14 14
USE Control output 2 4 to 20 mA DC
12 VDC 21 mA CT1 Transfer output
DO NOT 15 15 15 (Load 600 :max.)
15
USE

E53-CNQHHN2 E53-CNQFN2 E53-CN01N2 E53-CNH01N2 E53-CNQ01N2


Control Output 2 Control Output 2 and Communications Communications Communications (RS-232)
and CT2 Transfer Output (RS-232) (RS-232) and CT and Control Output 2
RS-232C RS-232C RS-232C
SD SD SD
Control output 2
11 11 11 11 11
Control output 2
12 VDC 21 mA 12 VDC 21 mA RD RD RD
12 12 12 12 12
DO NOT SG SG SG
13 13 13 13 13
USE
CT2 DO NOT
14 14 USE 14 14 14
4 to 20 mA DC Control output 2
CT1 Transfer output CT1
15 (Load 600 : DO NOT 12 VDC 21 mA
15 max.) USE 15 15 15

E53-CN03N2 E53-CNQ03N2 E53-CNH03N2 E53-CNHH03N2 E53-CNQHN2


Communications Communications (RS-485) Communications Communications Control Output 2
(RS-485) and Control Output 2 (RS-485) and CT (RS-485) and CT2 and CT

B () B () B () B ()


11 11 11 11 11
Control output 2
RS-485 RS-485 RS-485 RS-485 12 VDC 21 mA
12 12 12 12 12
A () A () A () A ()
DO NOT DO NOT DO NOT DO NOT
USE
13 13 13 13 USE
13
USE USE
DO NOT CT2
14 14 14 14 14
USE Control output 2
12 VDC 21 mA CT1 CT1 CT1
DO NOT
15 15 15 15 15
USE

Note: Wire all voltage input terminals correctly. The Controller may fail if voltage input terminals are wired incorrectly.

9
E5CN-H
Isolation/Insulation Block Diagrams

Transfer output

Temperature input/Analog input/CT input/Voltage pulse output

Power Communications/Event inputs


supply Linear current output/Linear voltage output

Relay output

Auxiliary output 1, 2

: Reinforced insulation : Functional insulation

Nomenclature
E5CN-H Temperature unit

SUB1
SUB2
SUB3 No. 1 display
Operation indicators HA

OUT1 STOP
OUT2 CMW MANU No. 2 display

Level Key Up Key

E5CN-H

Mode Key Down Key

Dimensions (Unit: mm)

E5CN-H
Panel Cutout
91
6 Mounted Separately Group Mounted
78 +1.0
(48 × number of units − 2.5) 0
48 × 48 1.5

+0.6
45 0

58 44.8 × 44.8 48.8


60 min. Group mounting does not
allow waterproofing.
• Recommended panel thickness is 1 to
45
+0.6
0
5 mm.
Waterproof Packing Mounting Adapter Terminal Cover • Group mounting is not possible in the
(Accessory, Y92S-P8 (Accessory, Y92F-49 (E53-COV17) vertical direction. (Maintain the specified
(also available for (also available for (Accessory) mounting space between Controllers.)
ordering separately)) ordering separately)) 45
+0.6
0
• To mount the Controller so that it is
waterproof, insert the waterproof packing
onto the Controller.
• When two or more Controllers are mounted,
make sure that the surrounding
Note: The terminal block cannot be removed. temperature does not exceed the allowable
operating temperature specified in the
specifications.

Accessories (Order Separately)


USB-Serial Conversion Cable
E58-CIFQ1

(2,100)
250 LED indicator 1,765
(SD)

USB connector (type A plug) Serial connector


LED indicator (RD)

10
E5CN-H

Terminal Cover Waterproof Packing


E53-COV17 Y92S-P8 (for DIN 48 × 48)

Order the Waterproof Packing separately if it becomes lost or


Note: The E53-COV10 damaged.
can not be used.
The Waterproof Packing can be used to achieve an IP66 degree of
protection.
(Deterioration, shrinking, or hardening of the waterproof packing may
48
occur depending on the operating environment. Therefore, periodic
replacement is recommended to ensure the level of waterproofing
specified in IP66. The time for periodic replacement depends on the
48.8 operating environment. Be sure to confirm this point at your site.
Consider one year a rough standard. OMRON shall not be liable for
the level of water resistance if the customer does not perform periodic
replacement.)
The Waterproof Packing does not need to be attached if a waterproof
22 structure is not required.

9.1

Current Transformers
E54-CT1 E54-CT1
21
15
2.8 Thru-current (Io) vs. Output Voltage
5.8 dia.
(Eo) (Reference Values)
7.5
Maximum continuous heater current: 50 A (50/60 Hz)
Number of windings: 400±2
25 3 Winding resistance: 18±2 Ω
100 V
Output voltage (Eo) V (r.m.s.)
10.5 50 Hz

40 10 ∞
1 kΩ Distortion
Two, 3.5 dia. factor 10%
1
3%
10
1%
100 mV
30

10 100 Ω

E54-CT3
2.36 dia. 1 RL = 10 Ω
30
12 dia.
9 100 μV

10
1 10 100 mA 1 10 100 1,000 A
40 × 40 Thru-current (Io) A (r.m.s.)

E54-CT3
Thru-current (Io) vs. Output Voltage
Two, M3 (depth: 4)
(Eo) (Reference Values)
15 Maximum continuous heater current: 120 A (50/60 Hz)
(Maximum continuous heater current for an OMRON
Temperature Controller is 50 A.)
30 Number of windings: 400±2
Winding resistance: 8±0.8 Ω
E54-CT3 Accessory 100 V
Output voltage (Eo) V (r.m.s.)

50 Hz
• Armature Connection Example Distor-
10
∞ tion
1 kΩ factor
Armature 10%
Approx. 3 dia. Plug 500 Ω 3%
1 1%
Lead

100 mV
100 Ω
50 Ω
18 10
RL = 10 Ω
• Plug
1

Approx. 6 dia. 100 μV

10
(22) 1 10 100 mA 1 10 100 1,000 A
Thru-current (Io) A (r.m.s.)

11
E5CN-H

Adapter
Y92F-45 Note: 1. Use this Adapter when the panel has already been prepared for the E5B@.
2. The Adapter is available only in black. Fixture (Accessory)
4.7 76
69.6 to 77.6
72 × 72

67 × 67 87

Mounted to E5CN-H
Panel (1 to 8 mm)
72 × 72

48 × 48

2.2 4.7
77.3 (to back of E5CN-H)

DIN Track Mounting Adapter


Y92F-52 Note: This Adapter cannot be used together with the Terminal Cover.
Remove the Terminal Cover to use the Adapter.

61

3.5
50 38

Mounted to E5CN-H

48

100.5

12
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.

Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.

Limitation on Liability; Etc.


OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.

Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.

Errors and Omissions.


Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.

2023.12
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2023 All Right Reserved.

You might also like