The H3YN is a miniature solid-state timer with multiple time ranges and operating modes, designed to minimize stock and compatible with MY Power Relay pin configuration. It conforms to EN61812-1 and IEC60664-1 standards, offering various supply voltages and contact types. The timer features selectable time ranges from 0.1 seconds to 10 hours, with options for DPDT and 4PDT outputs, and requires separate ordering for accessories and sockets.

Uploaded by

Jason Lim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3 views

Timer

The H3YN is a miniature solid-state timer with multiple time ranges and operating modes, designed to minimize stock and compatible with MY Power Relay pin configuration. It conforms to EN61812-1 and IEC60664-1 standards, offering various supply voltages and contact types. The timer features selectable time ranges from 0.1 seconds to 10 hours, with options for DPDT and 4PDT outputs, and requires separate ordering for accessories and sockets.

Uploaded by

Jason Lim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

Solid-state Timer

H3YN CSM_H3YN_DS_E_4_1

Miniature Timer with Multiple Time Ranges


and Multiple Operating Modes
• Minimizes stock.
• Pin configuration compatible with MY Power Relay.
• Standard multiple operating modes and multiple time ranges.
• Conforms to EN61812-1 and IEC60664-1 for Low Voltage, and
EMC Directives.

Model Number Structure


■ Model Number Legend
H3YN-@@-@
1 2 3
1. Output 3. Contact Type
2: DPDT None: Single contact
4: 4PDT Z: Twin contacts
2. Time Range
None: Short-time range (0.1 s to 10 min)
1: Long-time range (0.1 min to 10 hrs)

Ordering Information
■ List of Models
Supply voltage Time-limit contact Short-time range model Long-time range model
(0.1 s to 10 min) (0.1 min to 10 h)
24, 100 to 120, 200 to 230 VAC; DPDT H3YN-2 H3YN-21
12, 24, 48, 100 to 110, 125 VDC 4PDT H3YN-4 H3YN-41
24 VDC 4PDT (Twin contacts) H3YN-4-Z H3YN-41-Z

Note: Specify both the model number and supply voltage when ordering.
Example: H3YN-2 24 VAC

Supply voltage
Note: 1. Sockets and Hold-down Clips are not included with the H3YN. They must be ordered separately.
2. Only models with 24-VDC power supply are available.
3. Use the H3YN-4 or H3YN-41 Series when switching micro loads, and use the H3YN-4-Z or H3YN-41-Z Series when switching even
smaller loads.

1
H3YN
■ Accessories (Order Separately)
Adapter, Mounting Plate, Clip
Name/specification Model
Flush mounting adapter Y92F-78
Mounting Plate for Socket For 1 Socket PYP-1
For 18 Sockets PYP-18
Clip For PYF@A Y92H-3
For PY@ and PYF@M Y92H-4

Note: For details, refer to NTLP×REFERENCE Socket and DIN Track Products.

Socket
Timer Square Sockets
Contact Model Pin Connection Terminal Model
DIN track mounting PYF08A
DIN track mounting
H3Y-2 Front Connecting PYF08A-E
DPDT 8-pin (Finger-safe tyape)
H3YN-2@
Screw mounting PYF08F
Back Connecting Solder terminal PY08
DIN track mounting PYF14A
H3Y-4 Front Connecting DIN track mounting
4PDT 14-pin PYF14A-E
H3YN-4@ (Finger-safe tyape)
Back Connecting Solder terminal PY14

Note: 1. Cannot be used with the H3Y-@-0 (PCB terminals).


2. The PYF@@A-E has a finger-protection structure. Round crimp terminals cannot be used. Use forked crimp terminals.
3. For details, refer to Socket and DIN Track Products.

2
H3YN
Specifications
■ Ratings
Item H3YN-2/-4/-4-Z H3YN-21/-41/-41-Z
Time ranges 0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min max. 0.1 min to 10 h (1 min, 10 min, 1 h, or 10 h max.
selectable) selectable)
Rated supply voltage (See note 5.) 24, 100 to 120, 200 to 230 VAC (50/60 Hz) (See note 1.)
12, 24, 48, 100 to 110, 125 VDC (See note 2.)
Pin type Plug-in
Operating mode ON-delay, interval, flicker OFF start, or flicker ON start (selectable with DIP switch)
Operating voltage range 85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage)
(See note 3.)
Reset voltage 10% min. of rated supply voltage (See note 4.)
Power consumption 100 to 120 VAC: Relay ON: Approx. 1.8 VA (1.6 W) at 120 VAC, 60 Hz
Relay OFF: Approx. 1 VA (0.6 W) at 120 VAC, 60 Hz
200 to 230 VAC: Relay ON: Approx. 2.2 VA (1.8 W) at 230 VAC, 60 Hz
Relay OFF: Approx. 1.5 VA (1.1 W) at 230 VAC, 60 Hz
24 VAC: Relay ON: Approx. 1.8 VA (1.4 W) at 24 VAC, 60 Hz
Relay OFF: Approx. 0.3 VA (0.2 W) at 24 VAC, 60 Hz
12 VDC: Relay ON: Approx. 1.1 W at 12 VDC
Relay OFF: Approx. 0.1 W at 12 VDC
24 VDC: Relay ON: Approx. 1.1 W at 24 VDC
Relay OFF: Approx. 0.1 W at 24 VDC
48 VDC: Relay ON: Approx. 1.2 W at 48 VDC
Relay OFF: Approx. 0.3 W at 48 VDC
100 to 110 VDC: Relay ON: Approx. 1.6 W at 110 VDC
Relay OFF: Approx. 0.4 W at 110 VDC
125 VDC: Relay ON: Approx. 1.6 W at 125 VDC
Relay OFF: Approx. 0.4 W at 125 VDC
Control outputs DPDT: 5 A at 250 VAC, resistive load (cosφ = 1)
4PDT: 3 A at 250 VAC, resistive load (cosφ = 1)
Note: 1. Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Times for details.
2. Single-phase, full-wave-rectified power supplies can be used.
3. When using the H3YN continuously in any place where the ambient temperature is in a range of 45°C to 50°C, supply 90% to 110% of
the rated supply voltages (supply 95% to 110% with 12 VDC type).
4. Set the reset voltage as follows to ensure proper resetting.
100 to 120 VAC: 10 VAC max.
200 to 230 VAC: 20 VAC max.
100 to 110 VDC: 10 VDC max.
5. Refer to Safety Precautions for All Timers when combining the Timer with an AC 2-wire proximity sensor.

3
H3YN
■ Characteristics
Item H3YN-2/-21/-4/-41
Accuracy of operating time ±1% FS max. (1 s range: ±1%±10 ms max.)
Setting error ±10%±50 ms FS max.
Reset time Min. power-opening time: 0.1 s max. (including halfway reset)
Influence of voltage ±2% FS max.
Influence of temperature ±2% FS max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying
metal parts) (see note 1)
2,000 VAC, 50/60 Hz for 1 min (between operating power circuit and control output)
2,000 VAC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model)
1,500 VAC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Vibration resistance Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 1 h each in 3 directions
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in 3 directions
Shock resistance Destruction: 1,000 m/s2
Malfunction: 100 m/s2
Ambient temperature Operating: −10°C to 50°C (with no icing)
Storage: −25°C to 65°C (with no icing)
Ambient humidity Operating: 35% to 85%
Life expectancy Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical: DPDT:
500,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
4PDT:
200,000 operations min. (H3YN-4-Z/-41-Z: 100,000 operations min.)
(3 A at 250 VAC, resistive load at 1,800 operations/h) (see note 2)
Impulse withstand voltage Between power terminals:
3 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1 kV for 12 VDC, 24 VDC, 48 VDC, 24 VAC
Between exposed non-current-carrying metal parts:
4.5 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1.5 kV for 12 VDC, 24 VDC, 48 VDC, 24 VAC
Noise immunity ±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity Destruction: 8 kV
Malfunction: 4 kV
Degree of protection IP40
Weight Approx. 50 g
EMC (EMI) EN61812-1
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
(EMS) EN61812-1
Immunity ESD: EN61000-4-2: 8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
Immunity Surge: EN61000-4-5: 2 kV line to ground (level 3)
1 kV line to line (level 3)
Approved standards UL508, CSA C22.2 No. 14, Lloyds
Conforms to EN61812-1 and IEC60664-1. (2.5 kV/2 for H3YN-2/-21, 2.5 kV/1 for H3YN-4/-41, H3YN-
4-Z/-41-Z)
Output category according to EN60947-5-1.
Note: 1. Terminal screw sections are excluded.
2. Refer to the Life-test Curve.

4
H3YN
■ Life-test Curve (Reference Value)
H3YN-2/-21
Switching operations (x 103)

Switching operations (x 103)


5,000 250 VAC, cosφ = 1 5,000 250 VAC, cosφ = 0.4
24 VDC, cosφ = 1 24 VDC, L/R = 7 ms

1,000 1,000
500 500

200 200

Load current (A) Load current (A)

Reference: A maximum current of 0.6 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.
The minimum applicable load is 1 mA at 5 VDC (P reference value).

H3YN-4/-41
Switching operations (x 103)

Switching operations (x 103)

5,000 250 VAC, cosφ = 1 5,000 250 VAC, cosφ = 0.4


24 VDC, cosφ = 1 24 VDC, L/R = 7 ms

1,000 1,000

500 500

200 200

Load current (A) Load current (A)

Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.
The minimum applicable load is 1 mA at 1 VDC (P reference value).
H3YN-4-Z/-41-Z
Switching operations (x 103)

5,000

1,000
500 250 VAC, resistive load

100 24 VDC,
60 resistive load

Load current (A)

Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.
The minimum applicable load is 0.1 mA at 1 VDC (P reference value).

5
H3YN
Connections
■ Connection
H3YN-2/-21 H3YN-4/-41
DIN Indication H3YN-4-Z/-41-Z DIN Indication

Timer Timer
circuit circuit

UP PW UP PW

(Bottom View) (Bottom View)

Pulse Operation
A pulse output for a certain period can be obtained with a random external input signal.
Use the H3YN in interval mode as shown in the following timing charts.

H3YN-2/-21

Power (9-14)

External short circuit


(5-13)
50 ms
External input min.
(9-13)

Time limit contact


NO (12-8)
Timer Time limit contact
circuit NC (12-4)
Run/Power indicator
(PW)
Output indicator (UP)
External input
Note: t: Set time
Rt: Reset time
H3YN-4/-41
H3YN-4-Z/-41-Z

Power (9-14)

External short circuit


(5-13)
50 ms
External input min.
(9-13)
Time limit contact NO
(10-6, 11-7, 12-8)
Timer Time limit contact NC
circuit (10-2, 11-3, 12-4)
Run/Power indicator
(PW)
Output indicator (UP)
External input
Note: t: Set time
Rt: Reset time

!Caution
Be careful when connecting wires.

Mode Terminals
Pulse operation Power supply between 9 and 14
Short-circuit between 5 and 13
Input signal between 9 and 13
Operating mode; interval and all other modes Power supply between 13 and 14

6
H3YN
Operation
■ Timing Chart
Operating mode Timing chart
H3YN-2/-21 H3YN-4/-41
ON-delay
Power (13-14) Power (13-14)
Power
Time limit contact
Time limit contact NC (9-1, 10-2, 11-3,
NC (9-1, 12-4) 12-4)
Output
Time limit contact Time limit contact
NO (9-5, 12-8) NO (9-5, 10-6, 11-7,
12-8)
Run/Power indicator
(PW) Run/Power indicator
(PW)
Output indicator Output indicator
(UP)

Interval
Power (13-14) Power (13-14)
Power
Time limit contact
Time limit contact NC (9-1, 10-2, 11-3,
NC (9-1, 12-4) 12-4)
Output Time limit contact
Time limit contact
NO (9-5, 12-8) NO (9-5, 10-6, 11-7,
12-8)
Run/Power Run/Power
indicator (PW) indicator (PW)
Output indicator Output indicator
(UP) (UP)

Flicker OFF-start
Power (13-14) Power (13-14)
Power
Time limit contact Time limit contact
NC (9-1, 12-4) NC (9-1, 10-2, 11-3,
12-4)
Output Time limit contact Time limit contact
NO (9-5, 12-8) NO (9-5, 10-6, 11-7,
12-8)
Run/Power indicator Run/Power indicator
(PW) (PW)
Output indicator Output indicator
(UP) (UP)

Flicker ON-start
Power (13-14) Power (13-14)

Power Time limit contact


Time limit contact
NC (9-1, 12-4) NC (9-1, 10-2, 11-3,
12-4)
Output Time limit contact Time limit contact
NO (9-5, 12-8) NO (9-5, 10-6, 11-7,
12-8)
Run/Power Run/Power
indicator (PW) indicator (PW)
Output indicator Output indicator
(UP) (UP)

Note: t: Set time


Rt: Reset time

7
H3YN
■ DIP Switch Settings
The 1-s range and ON-delay mode for H3YN-2/-4/-4-Z, the 1-min range and ON-delay mode for H3YN-21/-41/-41-Z are factory-set before shipping.

Time Ranges
Model Time range Time setting Setting Factory-set
range
H3YN-2, 1s 0.1 to 1 s Yes
H3YN-4
H3YN-4-Z 10 s 1 to 10 s No

1 min 0.1 to 1 min No

10 min 1 to 10 min No

H3YN-21, 1 min 0.1 to 1 min Yes 1s 10 s 1 min 10 min

H3YN-41
H3YN-41-Z 10 min 1 to 10 min No

1h 0.1 to 1 h No

10 h 1 to 10 h No

Note: The top two DIP switch pins are used to select the time ranges.

Operating Modes
Operating mode Setting Factory-set
ON-delay Yes

Interval No

Flicker OFF-start No

Flicker ON-start No

Note: The bottom two DIP switch pins are used to select the operating mode.

Nomenclature

Output Indicator (Orange) Run/Power Indicator (Green)


(Lit: Output ON) (Lit: Power ON)

Main Dial
Set the desired time according
to time range selectable by
DIP switch.

8
H3YN
Dimensions
Note: All units are in millimeters unless otherwise indicated.

■ Timers
H3YN-2/-21 Front Mounting

Mounting Holes
Pin 1
Eight, 3 × 1.2 elliptic holes

28 max.

6.4 Eight,
21.5 max. 1.3-dia. holes
(63.0)

H3YN-4/-41 Front Mounting


H3YN-4-Z/-41-Z

Mounting Holes
Pin 1
Fourteen, 3 × 1.2 elliptic holes

28 max.

Fourteen,
21.5 max. 1.3-dia. holes

Mounting Height

PYF08A/PYF08A-N/PYF08A-E PY08 (PY14 (see note)) PY08QN (PY14QN (see note))


(PYF14A/PYF14A-N/PYF14A-E
(see note))

H3YN H3YN H3YN


Series Series Series

PY08QN
PY08 (PY14) (PY14QN)
PYF08A (PYF14A)

Note: Models in parentheses are Connecting Sockets to the H3YN-4/-41 or H3YN-4-Z/-41-Z.

9
H3YN
■ Accessories (Order Separately)
Connecting Sockets
Use the PYF@A, PY@, PY@-02, or PY@QN(2) to mount the H3YN. When ordering any one of these Sockets, replace “@” with “08” or “14.”

Track Mounting/Front Connecting Sockets


PYF08A
Two, 4.2 × 5 6 3.4 Terminal Arrangement Mounting Holes
mounting holes
Eight, M3 × (Top View)
8 sems Two, 4.5 dia.
M4 or M3

H3YN
Series
72 max. 35.4 90.5 86.6
59±0.3

4
6 PYF@A
23 max. 15±0.2
16.5
30 max.
PYF-14A
Two, 4.2 × 5 6 3.4 Terminal Arrangement Mounting Holes
mounting holes
Fourteen, M3 × (Top View)
8 sems Two, 4.5 dia.
M4 or M3

72 max. 35.4
59±0.3

29.5 max. 6 22±0.2


16.5
30 max.

PYF-08A-N
Terminal Arrangement Mounting Holes
(for Surface Mounting)
4 1
42 12
12
4 1
42

8 5
44 14
44 14
8 5

3.2 dia.
66.5 max.
19.8 3.6 dia.

PYF-08A-N
41 11

12 9
12 9
A2 A2 A1 41 11
14 14 13
14 14 13
A2 A2 A1
30 max.
22 max.

PYF-14A-N
Terminal Arrangement Mounting Holes
(for Surface Mounting)
42 32 22 12
4 3 2 1
4 3 2 1
42 32 22 12
44 34 24 14
8 7 6 5 8 7 6 5 Two, 3.5 dia.
44 34 24 14

66.5 max.

PYF-14A-N
41 31 21 11

12 11 10 9

A2 A2 A1
12 11 10 9 20.8
14 14 13
41 31 21 11
30 max. 14 14 13
29.5 max. A2 A2 A1

10
H3YN
PYF08A-E
(Top View)
Two, 4.2 × 5 Two, 4.5 dia.
mounting holes Eight, M3 ×
8 sems M4 or M3

72 max.

23 max.

31 max.

PYF14A-E (Top View)


Two, 4.2 × 5 Two, 4.5 dia.
mounting holes M4 or M3
Fourteen,
M3 × 8
sems

72 max.

29.5 max.

31 max.

Back Connecting Sockets


PY08, PY14

Terminal Arrangement Panel Cutout


Eight, 3 × 1.2 dia. holes
only for PY08 (Fourteen, 3 (Bottom View)
× 1.2 dia. holes) 21.4+0.2
0
24 max.

0.3 H3YN
25.5 29.5 59.3 Series
max. max. 25.8+0.2
0

2.7 7.7 2.6

20 max. PY08 PY14


PY@, PY@-02,
PY08QN, PY14QN PY@QN(2)
PY08QN(2), PY14QN(2)
Terminal Arrangement
24 max. (Bottom View)
2.7 25 max. * 22 max.
(See
note)

29.5 max.

1x1
**
41.5 max.
(see note) PY08QN PY14QN
PY08QN(2) PY14QN(2)
Note: With PY@QN(2)(-3), dimension * should
read 20 max. and dimension ** 36.5 max.

PY08-02, PY14-02 Terminal Arrangement


22 max. (Bottom View)

0.3
25.5 29.5
max. max.

4.3
2.7 2

16.5 max.
PY08@-02 PY14@-02

11
H3YN
Flush Mounting Adapter
Y92F-78

Panel Cutout
R0.5 max. 25.2+0.2
−0 5

31.6+0.2
−0

27.1 3 48.5 25.1


3

33.5 31.5
Panel thickness
1 to 3 mm

Note: 1. Push the H3Y in until the Adaptor (Y92F-78)


hooks engage with its rear panel.
2. Do not round the corners of the cutout on
the rear panel surface, otherwise the
Adaptor (Y92F-78) tabs may not engage
properly.

Socket Mounting Plates


The PYP-1 is a Socket Mounting Plate for a single Socket and the PYP-18 is a Socket Mounting Plate for 18 Sockets. The PYP-18 can be cut
appropriately according to the number of Sockets to be used.

PYP-1 PYP-18 492


Two, 3.4-dia. holes 17 x 27.4 = 465.8±0.6
27.4±0.15 13.1
21.6 4.5
49 3.4

28 t = 1.6 42±0.1 49
Square hole

72, elliptic holes


t = 1.6

Hold-down Clips
The Hold-down Clip makes it possible to mount the H3YN securely and prevent the H3YN from falling out due to vibration or shock.

Y92H-3 Y92H-3 for Y92H-4 for


Y92H-4 PYF@A Socket PY@ Socket
(Set of Two Clips)
5 max. 9R

30.5
24.5 2.5
53

20 (84°)

4.5
4.5 1.2 33.7

12
H3YN
Safety Precautions
Refer to Safety Precautions for All Timers.

■ Correct Use Be careful not to apply any voltage to the terminal screws on the
back of the Timer. Mount the product so that the screws will not come
in contact with the panel or metal parts.
The operating voltage will increase when using the H3YN continu-
ously in any place where the ambient temperature is in a range of Do not use the H3YN in places where there is excessive dust, corro-
45°C to 50°C. Supply 90% to 110% of the rated voltages (at 12 VDC: sive gas, or direct sunlight.
95% to 110%).
Do not mount more than one H3YN closely together, otherwise the
Do not leave the H3YN in time-up condition for a long period of time internal parts may become damaged. Make sure that there is a
(for example, more than one month in any place where the ambient space of 5 mm or more between any H3YN models next to each
temperature is high), otherwise the internal parts (aluminum electro- other to allow heat radiation.
lytic capacitor) may become damaged. Therefore, the use of the
The internal parts may become damaged if a supply voltage other
H3YN with a relay as shown in the following circuit diagram is recom-
than the rated ones is imposed on the H3YN.
mended to extend the service life of the H3YN.
In order to conform to UL and CSA requirements when using the
H3YN-4/-41 or H3YN-4-Z/-41-Z, connect the Unit so that output con-
tacts (contacts of different poles) have the same electric potential.
X2/b T/a X1/a X1/a
In cases such as PLC input where the load is extremely small for the
control output of a timer containing a power relay (using other than
T X1 X2 gold-plated contacts), reliability can be increased by using contacts
of the same poles (e.g., the H3Y-2) in parallel.
: Auxiliary relay such as MY Relay
■ Precautions for EN61812-1
X

The H3YN must be disconnected from the Socket when setting the
DIP switch, otherwise the user may touch a terminal imposed with a
high voltage and get an electric shock. Conformance
Do not connect the H3YN as shown in the following circuit diagram The H3YN as a built-in timer conforms to EN61812-1 provided that
on the right hand side, otherwise the H3YN’s internal contacts differ- the following conditions are satisfied.
ent from each other in polarity may become short-circuited.

Correct Incorrect Handling


Do not touch the DIP switch while power is supplied to the H3YN.
L2
Before dismounting the H3YN from the Socket, make sure that no
voltage is imposed on any terminal of the H3YN.
L1 L2 L1 The applicable Socket is the PYF@A.
Only basic insulation is ensured between the Y92H-3 Hold-down
Use the following safety circuit when building a self-holding or self- Clips and H3YN internal circuits.
resetting circuit with the H3YN and an auxiliary relay, such as an MY
Do not allow the Y92H-3 Hold-down Clips to contact other parts.
Relay, in combination.
The insulation test voltage between different pole contacts for the 4-
pole model is the impulse voltage of 2.95 kV.

Wiring
The power supply for the H3YN must be protected with equipment
such as a breaker approved by VDE.
: Auxiliary relay such as MY Relay
Basic insulation is ensured between the H3YN’s operating circuit and
control output.
In the case of the above circuit, the H3YN will be in pulse operation.
Therefore, if the circuit shown on page 6 is used, no auxiliary relay Basic insulation: Overvoltage category II,
will be required. pollution degree 1 (H3YN-4/-41, H3YN-4-Z/-
41-Z), pollution degree 2 (H3YN-2/-21)
Do not set to the minimum setting in the flicker modes, otherwise the (with a clearance of 1.5 mm and a creepage
contact may become damaged. distance of 2.5 mm at 240 VAC)

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.


To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

In the interest of product improvement, specifications are subject to change without notice.

13
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR


FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE


OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

 Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

 Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.

 Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS


Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS


The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

2011.10
In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2011 All Right Reserved.