TR 45-150 Roof & Wall Sandwich Panel Data Sheet 9-3-14

The TigerPROFILES TR 45/150 sandwich panel is designed for roof and wall applications, available in various materials including aluminum, Alu-Zinc, and galvanized iron with thicknesses ranging from 0.30 to 1.2 mm. It offers insulation options such as PUR and PIR foam, providing excellent thermal resistance and fire safety features. The product data sheet includes detailed specifications on dimensions, section properties, allowable loads, and insulation characteristics, ensuring compliance with relevant standards.

Uploaded by

jihado2110
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views11 pages

TR 45-150 Roof & Wall Sandwich Panel Data Sheet 9-3-14

The TigerPROFILES TR 45/150 sandwich panel is designed for roof and wall applications, available in various materials including aluminum, Alu-Zinc, and galvanized iron with thicknesses ranging from 0.30 to 1.2 mm. It offers insulation options such as PUR and PIR foam, providing excellent thermal resistance and fire safety features. The product data sheet includes detailed specifications on dimensions, section properties, allowable loads, and insulation characteristics, ensuring compliance with relevant standards.

Uploaded by

jihado2110
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

Roof & Wall Sandwich Panel TR 45/150

Product Data Sheet Page 1 of 11

PRODUCT DESCRIPTION
TigerPROFILES TR 45/150 sandwich panel is applicable in its usage for roof and wall applications.

Measurement (in mm) Roofing Wall Cladding

Usage

Aluminum (Inner & outer Skin options)

Alu-Zinc (outer skin option)


Material
Galvanized Iron (GI) (Inner & Outer Skin Options)
Aluminum Foil (Inner Skin option)

Aluminum: 0.35 - 1.2 Aluminum: 0.35 - 1.2


Material Thickness
Alu-Zinc: 0.30 - 0.90 Alu-Zinc: 0.30 - 0.90
(Post Production)
Galvanized Iron (GI): 0.30 - 0.90 Galvanized Iron (GI): 0.30 - 0.90

Covering Width: 900 Covering Width: 900

Profile Pitch: 150 Profile Pitch: 150

Profile Depth: 45 Profile Depth: 45


Dimensions
Crown: 30 Crown: 30

Valley: 50 Valley: 50

Rib Width: 100 Rib Width: 100

Colors Standard RAL Colors. Special colors on request; min. order applied

Pre-painted Polyester Pre-painted Polyester

Coating/Finish Pre-painted PVDF Pre-painted PVDF

Mill-Finish Mill-Finish

PUR 35 AND PUR 40 (B2)(Foam) available in thickness of : 50-200mm

Insulation Options Hi PIR 45 (Foam) : 50-200mm available in thickness of : 50-200mm

Mineral Wool available in thickness of : 50-200mm

Key Features

Curved eave TR 45/150, PB Ridge, flashing, gutters, GI Self-tapping screws with neo-
Accessories prene, SS Self-drilling screws with neoprene, Butyle Sealant tape, Purlin Tape, PVC Tape,
PVC Color Caps, Aluminum Rivets, Bulb-tite Rivets, Fil1er Blocks Silicon Sealant.

T: +971 6 533 8449


F: +971 6 533 6673
E: [email protected]
The Roof & Cladding Company Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isn’t intended to replace
engineering judgment—for support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .
Roof & Wall Sandwich Panel TR 45/150
Product Data Sheet Page 2 of 11

SECTION PROPERTIES (PER METER WIDTH) BASE METAL: ALUMINIUM

Elastic Top in Compression Bottom in Compression


Thickness Cover Nominal
Area Full Sect. Modulus
Width Weight
(T) (mm) (cm2) Ix (cm4) ( E )(kN/ Ixet Sx-Top Sx-Bot Ma bx Ixeb Sx-Top Sx-Bot Ma bx
(mm) (kg/m2)
cm2) (cm4) (cm3) (cm3) (kNm) (cm4) (cm3) (cm3) (kNm)

0.70 9.66 123.0


900 6.820 209.71 6900 180.92 30.24 52.78 2.63 29.57 24.20 2.11
0.50 6.11 0

ALLOWABLE UNIFORM LOADS (KN/M2): BASE METAL: ALUMINIUM

Nominal
No. of Load Span (m)
Thickness
Spans Case
( T ) (mm) 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50

1 *D + L 21.05 13.47 9.35 6.87 5.26 4.16 3.37 2.78 2.29 1.80 1.44

**WS 16.84 10.78 7.49 5.50 4.21 3.33 2.69 2.23 1.87 1.59 1.37

2 D+L 12.36 8.66 6.37 4.86 3.82 3.08 2.53 2.11 1.79 1.53 1.33
0.7 + 0.5
WS 13.77 9.89 7.41 5.73 4.56 3.70 3.06 2.57 2.18 1.88 1.63

3 D+L 14.09 10.08 7.52 5.81 4.60 3.73 3.08 2.58 2.19 1.89 1.64

WS 15.39 11.27 8.58 6.73 5.40 4.42 3.68 3.11 2.53 1.99 1.59

Notes:
 *D+L = Dead + Live Load  Nominal Thickness refers to Base Metal Thickness
 **WS= Wind Suction  Assume bond with insulation ensures that lateral
 Design of sheeting is based on AISI -2007 sliding of sheet does not occur, and insulation
(ASD-Allowable Stress Design) doesn't have significant compression
 Deflection Limits - Span / 180

T: +971 6 533 8449


F: +971 6 533 6673
E: [email protected]
The Roof & Cladding Company Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isn’t intended to replace
engineering judgment—for support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .
Roof & Wall Sandwich Panel TR 45/150
Product Data Sheet Page 3 of 11

SECTION PROPERTIES (PER METER WIDTH) BASE METAL: STEEL

Elastic Top in Compression Bottom in Compression


Thickness Cover Nominal
Area Full Sect. Modulus
Width Weight
(T) (mm) (cm2) Ix (cm4) ( E )(kN/ Ixet Sx-Top Sx-Bot Ma bx Ixeb Sx-Top Sx-Bot Ma bx
(mm) (kg/m2)
cm2) (cm4) (cm3) (cm3) (kNm) (cm4) (cm3) (cm3) (kNm)

0.50 6.80
900 11.100 142.20 20300 107.20 17.00 36.10 2.35 68.00 18.20 12.35 1.70
0.40 4.78

ALLOWABLE UNIFORM LOADS (KN/M2): BASE METAL: STEEL

Nominal
No. of Load Span (m)
Thickness
Spans Case
( T ) (mm) 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50

1 *D + L 18.08 12.03 8.36 6.14 4.70 3.71 3.01 2.49 2.09 1.78 1.53

**WS 13.60 8.70 6.04 4.44 3.40 2.69 2.18 1.80 1.51 1.29 1.11
2 D+L 9.91 6.96 5.12 3.91 3.08 2.48 2.04 1.70 1.44 1.24 1.07
0.5 + 0.4
WS 11.46 8.34 6.31 4.93 3.94 3.22 2.67 2.25 1.92 1.65 1.44

3 D+L 11.28 8.08 6.04 4.67 3.70 3.00 2.48 2.08 1.77 1.52 1.32
WS 12.68 9.41 7.24 5.73 4.63 3.81 3.10 2.70 2.32 2.01 1.73

Notes:  Material Specifications - ASTM A653 - Yield Strength


 *D+L = Dead + Live Load - 230 Mpa
 **WS= Wind Suction  Nominal Thickness refers to Base Metal Thickness
 Design of sheeting is based on AISI -2007  Assume bond with insulation ensures that lateral
(ASD-Allowable Stress Design) sliding of sheet does not occur, and insulation
 Deflection Limits - Span / 180 doesn't have significant compression

T: +971 6 533 8449


F: +971 6 533 6673
E: [email protected]
The Roof & Cladding Company Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isn’t intended to replace
engineering judgment—for support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .
Roof & Wall Sandwich Panel TR 45/150
Product Data Sheet Page 4 of 11

OUR FOAM INSULATION OPTIONS FOR OUR ROOF AND WALL PANELS

TigerPROFILES produces insulated panels with standard BS EN 13165: 2008 (Thermal


foam cores as follows: Insulation products for buildings – Factory
made rigid polyurethane foam (PUR & PIR)
 PUR – (Polyurethane) : with 90% minimum
products).
closed cells. Available in thicknesses from
50-200mm. Some Advantages of using our Foam Insulated
Roof and Wall Sandwich Panels include:
Rigid polyurethane (PUR) materials are cellular
thermosetting insulation materials that typically  Excellent insulation values for roof and
form a char/burn when subject to heat and walls ; and no thermal bridges and thus
flame impingement. The char acts as an able to significantly lowers HVAC costs—
insulator that affords some protection to the with .
underlying product. However, PUR will burn  Excellent air and water tightness.
by charring and producing significant
 Effective vapor barrier performance
quantities of smoke in the process.
 Negligible reduction in long term
 PUR B2: This core produces no
thermal resistance R-value.
flaming droplets during a fire and is
self-extinguishing, which means that the  Eco-friendly production that allows
core stops burning when the heat source panels to be manufactured with the use of
disappears. Studies have also shown that a N-pentane blowing agents that have ZERO
PUR panel that is fixed to the framework DOP and low GWP
with a continuous mechanical fastener
 Lightweight for easy and speedy
does not fail until the structural framework
assembly; strong support and available in
fails.
long spans
 PIR – (Polyisocyanurate) : with 90%
 Easy to tailor to suit different dimensions
minimum closed cells. Available in and shapes
thicknesses from 50-200mm.
 Greatly decreases carbon emission of
Rigid polyisocyanurate (PIR) insulation that is a buildings
type of polyurethane that has undergone
significant material modification.  Wall panel systems are ideal for both low
and highrise buildings
In the event of a fire the core chars on the
exposed side; this charred layer then  Extra space in structures due to thinner
protects the rest of the core from the fire. This insulation requirement when compared
means that a panel with a PIR core is more with conventional insulation options
resistant to fire than a PUR B2 core. It also emits  Can easily replace concrete walls thus
less heat and smoke. reducing cost, structure weight and harmful
TigerPROFILES PUR and PIR sandwich panel cores carbon emissions from concrete
are approved and certified by Dubai
Municipality as Class E against the

T: +971 6 533 8449


F: +971 6 533 6673
E: [email protected]
The Roof & Cladding Company Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isn’t intended to replace
engineering judgment—for support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .
Roof & Wall Sandwich Panel TR 45/150
Product Data Sheet Page 5 of 11

LENGTH AND WIDTH TOLERANCES ACCORDING TO BS EN 13165: 2012

Dimensions (mm) Tolerances (mm)


FIGURES FOR (PUR) INSULATION

<1000 ±5

1000 to 2000 ±7.5

2001 to 4000 ±10

>4000 ±15

THICKNESS TOLERANCES ACCORDING TO BS EN 13165: 2012

Class Nominal Thickness (mm)


FIGURES FOR (PUR)

<50 50 to 75 >75
T2
±2 ±3 +5,-3

VALUES ACCORDING TO BS EN 13165: 2012

Compressive Strength or Stress

CS(10\Y)100 i.e. ≥100 kPa


FIGURES FOR (PUR) INSULATION

Density

≥38 kg/m3

Thermal Conductivity (Initial Value)

λD : 0.029 W/(m.K) @ T=35ºC & RH=60%

Thermal Conductivity (Aged Value)

0.0326 W/(m.K)

T: +971 6 533 8449


F: +971 6 533 6673
E: [email protected]
The Roof & Cladding Company Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isn’t intended to replace
engineering judgment—for support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .
Roof & Wall Sandwich Panel TR 45/150
Product Data Sheet Page 6 of 11

DIMENSIONAL STABILITY ACCORDING TO BS EN 13165: 2012


FIGURES FOR (PUR) INSULATION

Test condition Relative Changes Level DS(TH)8


Δεl
% ≤2
DS (70,90)
48H, (70 OC,RH ΔεB % ≤6

VALUES ACCORDING TO BS EN 13165: 2012

Water Vapor Transmission


 Water vapor diffusion resistance factor (µ) : 80.14
 Water vapor resistance (Z) : 5.4897 m2hPa/mg

General Specifications

 Nominal Thickness (min) : 50 mm for roof and wall


 Length (max) : 16 m
FIGURES FOR (PUR) INSULATION

 Width (max) : 1150 mm


 Reaction to Fire meets Euro Class E Fire Classification
 Code : PU-EN 13165-T2-DS(70,90)3-CS(10\Y)100-MU80
 Manufactured either with aluminum foil facing or, flat
or corrugated metal sheet on both or either sides to be used as
thermal insulation sandwich panel.
 n-Pentane is used as blowing agent; therefore
Chlorofluorocarbons (CFC’s) have not been used in
manufacturing of this product.
 n-Pentane blowing agent has ZERO ODP (Ozone Depletion
Potential) and low GWP (Global Warming Potential)
 Approved by Dubai Municipality under certificate number:
CL10020138

T: +971 6 533 8449


F: +971 6 533 6673
E: [email protected]
The Roof & Cladding Company Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isn’t intended to replace
engineering judgment—for support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .
Roof & Wall Sandwich Panel TR 45/150
Product Data Sheet Page 7 of 11

LENGTH AND WIDTH TOLERANCES ACCORDING TO BS EN 13165: 2012

Dimensions (mm) Tolerances (mm)


FIGURES FOR (PIR) INSULATION

<1000 ±5

1000 to 2000 ±7.5

2001 to 4000 ±10

>4000 ±15

THICKNESS TOLERANCES ACCORDING TO BS EN 13165: 2012

Class Nominal Thickness (mm)


FIGURES FOR (PIR)

<50 50 to 75 >75
T2
±2 ±3 +5,-3

VALUES ACCORDING TO BS EN 13165: 2012

Compressive Strength or Stress

CS(10\Y)100 i.e. ≥100 kPa


FIGURES FOR (PIR) INSULATION

Density

≥38 kg/m3

Thermal Conductivity (Initial Value)

λD : 0.025 W/(m.K) @ T=35ºC & RH=60%

Thermal Conductivity (Aged Value)

0.0299 W/(m.K)

T: +971 6 533 8449


F: +971 6 533 6673
E: [email protected]
The Roof & Cladding Company Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isn’t intended to replace
engineering judgment—for support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .
Roof & Wall Sandwich Panel TR 45/150
Product Data Sheet Page 8 of 11

DIMENSIONAL STABILITY ACCORDING TO BS EN 13165: 2012

Test condition Relative Changes Level DS(TH)8


FIGURES FOR (PIR) INSULA-

Δεl
% ≤1
DS (70,90) Δεb

48H, (70 OC,RH


Δεd % ≤4

VALUES ACCORDING TO BS EN 13165: 2012

Water Vapor Transmission

 Water vapor diffusion resistance factor (µ) : 109.13


 Water vapor resistance (Z) : 7.4731 m2hPa/mg

General Specifications

 Nominal Thickness (min) : 50 mm for roof and wall


 Length (max) : 16 m
FIGURES FOR (PIR) INSULATION

 Width (max) : 1150 mm


 Reaction to Fire meets Euro Class E Fire Classification
 Code : PU-EN 13165-T2-DS(70,90)4-CS(10\Y)100-MU109
 Manufactured either with aluminum foil facing or, flat
or corrugated metal sheet on both or either sides to be
used as thermal insulation sandwich panel.
 n-Pentane is used as blowing agent; therefore
Chlorofluorocarbons (CFC’s) have not been used in
manufacturing of this product.
 n-Pentane blowing agent has ZERO ODP (Ozone
Depletion Potential) and low GWP (Global Warming
Potential)
 Approved by Dubai Municipality under certificate
number: CL10020138

T: +971 6 533 8449


F: +971 6 533 6673
E: [email protected]
The Roof & Cladding Company Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isn’t intended to replace
engineering judgment—for support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .
Roof & Wall Sandwich Panel TR 45/150
Product Data Sheet Page 9 of 11

OUR MINERAL WOOL (ROCKWOOL®) OPTION FOR OUR ROOF AND WALL PANELS

TigerPROFILES produces insulated panels Advantages of using our Mineral Wool


with a mineral wool (also known as Insulated Roof and Wall Sandwich Panels
Rockwool®) core as follows: include:

 Mineral Wool core also known as  Optimum thermal insulation values and
Rockwool: available in thicknesses from no thermal bridges
50-200mm and a minimum density of  Higher fire safety than other insulation
100kg/m3. cores
We produce mineral wool insulated panels  Lightweight for easy assembly on
through the use of rigid slabs conforming to various supporting structures
ASTM C-612 and equivalent 8S-3958-5 that
 Wall panel systems are ideal for both
are designed for thermal and acoustic
low and highrise buildings
insulation operating at temperatures up to
750ºC. These rigid slabs are produced from  Extra space due to thinner insulation:
long, non-combustible resin bonded fibers with pitched roofs, the second layer,
with excellent load bearing characteristics. required by other types of insulation, is
They are easy to cut, fit and handle. The unnecessary, and with flat roofs and
robust fibers combine high levels of floors the reduced height of the
thermal efficiency and acoustic structure is an advantage Increased
absorption. scope for design because walls can be
made thinner
When incorporated within a sandwich
panel structure mineral wool insulating  Greater comfort and a better interior
core materials are suitable for a range of climate in buildings
applications where fire retardant
properties are essential, for example
internal and external walls, ceilings and
partitions.
TigerPROFILES mineral wool sandwich panel
core is approved and certified by Dubai
Municipality as Class E against the
standard ASTM C 612 –10 for Mineral Fiber
Block and Board Thermal Insulation

T: +971 6 533 8449


F: +971 6 533 6673
E: [email protected]
The Roof & Cladding Company Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isn’t intended to replace
engineering judgment—for support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .
Roof & Wall Sandwich Panel TR 45/150
Product Data Sheet Page 10 of 11

VALUES AND SPECIFICATIONS (MINERAL WOOL INSULATION CORE—SEMI-RIGID SLABS)

Moisture

Water repellent, non-hygroscopic, non-capillary, and does not


absorb any moisture rom the air. Moisture has no effect on the
stability of the slabs.

Fire Safety
FIGURES FOR (MINERAL WOOL/ROCKEWOOL®) INSULATION

Non-combustible when tested in accordance with B8-476: Part 4 and


A8TM E-136. Class I, when tested in accordance with BS 476 part 7
and ASTM E - 84.

Biological Properties

Rot-proof, non-hygroscopic, will not sustain vermin and will not


encourage growth of bacteria, mold or fungi.

Physical Properties

Asbestos-free and shot content is very low when tested as per ASTM C
-1335 and BS-2972 Section 14.

Compatibility

Compatible with all other forms of material with which it is likely to


come in contact in normal industrial and building applications.

Chemically Neutrality

Chemically neutral with a pH value of 7.3 when tested in accordance


with BS-2972 : Section 22 and ASTM C-871 It will neither cause nor
promote corrosion. It meets the requirements of ASTM C-795 the
standard specification for thermal insulation for use in contact with
austenitic stainless steel as per ASTM C-692 (Corrosion test) and ASTM
C-871 (Chemical analysis). It contains low level of chlorides when
tested in accordance with BS 2972 : Section 21, ASTM C-871 and AG I
Q 135.

T: +971 6 533 8449


F: +971 6 533 6673
E: [email protected]
The Roof & Cladding Company Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isn’t intended to replace
engineering judgment—for support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .
Roof & Wall Sandwich Panel TR 45/150
Product Data Sheet Page 11 of 11

THERMAL CONDUCTIVITY VALUES* (MINERAL WOOL INSULATION CORE—SEMI-RIGID SLABS)

Mean Temperature k-Value W/mK k-Value W/mK


FIGURES FOR (MINERAL WOOL) INSULATION

(oC) 100 kg/m3 120 kg/m3

50 0.037 0.037

100 0.044 0.044

150 0.052 0.052

200 0.061 0.060


250 0.072 0.070

300 0.084 0.082

350 0.098 0.096


400 0.118 0.110

*The Mineral Wool that we use shows remarkably low thermal conductivity
values with typical figures shown above as tested in accordance with BS 874,
equivalent ASTM C177/C518 (180 8302/180 8301) & DIN 52612 standards.

ACOUSTIC VALUES** (MINERAL WOOL INSULATION CORE—SEMI-RIGID SLABS)

Hz 100 kg/m3 120 kg/m3


FIGURES FOR (MINERAL WOOL)

125 0.23 0.23

250 0.66 0.66

500 1.05 1.05


1,000 1.07 1.06
2,000 1.05 1.05
4,000 0.97 0.97

**Typical sound absorption figures shown above are in accordance with BS


3638 & ISO 0354

T: +971 6 533 8449


F: +971 6 533 6673
E: [email protected]
The Roof & Cladding Company Website: TigerPROFILES.com
Information contained here was, at the time of publishing, accurate and true to the best of our knowledge, but isn’t intended to replace
engineering judgment—for support please contact our sales Dept. We reserve the right to make any changes for continuous improvement .

You might also like