0% found this document useful (0 votes)
55 views20 pages

Bee Automation - Schematic Workbook_EDIT

The document provides technical details about PLC systems, including components like the SRMV and SRMAC relay modules, which convert analog signals to relay outputs for controlling heating pumps and boilers. It also describes the IQ241 controller, which manages various building plant operations with multiple digital and analog inputs and outputs. The IQ241 can function independently or as part of a Building Management System, offering extensive capabilities for complex control strategies.

Uploaded by

iambasnetsuraj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views20 pages

Bee Automation - Schematic Workbook_EDIT

The document provides technical details about PLC systems, including components like the SRMV and SRMAC relay modules, which convert analog signals to relay outputs for controlling heating pumps and boilers. It also describes the IQ241 controller, which manages various building plant operations with multiple digital and analog inputs and outputs. The IQ241 can function independently or as part of a Building Management System, offering extensive capabilities for complex control strategies.

Uploaded by

iambasnetsuraj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

PLC

with in the panel

This horizontal line is a divide between what's in the field and what's in the panel

out infield

Temperature Sensor out in field


3-PHASE Connection
Inputs with digital signal

contacts

heating pumps outside with dps means differential pressure switch


PLC

They are trend relays SRMV which takes not 10V


signal and convert them to digital output signal

chanel 39 and 37 giving put 1-10 V DC


signal means 0-10V Analog outputs to boiler 1 and boiler 2
Where 24 volts DC controls start.

MCB: Miniature circuit breaker

Control voltage start


controlled continued

Detail on boiler control


Detail on boiler control

pumps

pumps signal
Comtrol for Water heater
Data Sheet
SRMV, SRMAC
Single Relay Module

Single Relay Module

Type text here

Description Features
The Single Relay Module enables a controller output signal to • SRMV converts a 10 Vdc analogue output signal to a 8 A relay output
drive a single changeover relay. This allows plant of up to 8A • SRMAC converts a 24 Vac (triac) output signal to a 10 A relay output
at 240 Vac resistive to be switched by the relay contacts. The • Can be mounted on a DIN rail or any flat surface
module may either be mounted on a DIN rail or on a flat surface.
There are two versions: the SRMV accepts a 0 to 10 V signal,
and the SRMAC accepts a 0 to 24 Vac signal (e.g. triac output).

Physical
coil terminals
relay contact termnals
11 C O N C
A2 coil A1
15.5 mm
(0.61”)

NO 14

12

75.5 mm (2.97”)
42 mm (1.65”)

SRMV, SRMAC Data Sheet 91-0617 Issue 5/D 18/06/07 1


Data Sheet
IQ241
Controller

IQ241 Controller

Description Features
The IQ241 controllers are of medium capacity designed for the • 1 second cycle time.
control of all types of building plant. They can provide a minimum of • Optional integral/external Display Panel.
12 digital inputs, and 8 analogue voltage outputs. A further 20 I/O • Access to entire network by way of local supervisor
points can be made available by using up to 10 S cards, each connection.
providing 2 inputs or outputs of the same type (8 input only, 12 input • Facility for mounting an additional node controller.
or output). S cards can provide analogue current, analogue voltage, • High capacity DDC with PID control loops.
thermistor, or digital inputs, or analogue voltage outputs giving the • Stand alone or integrated system operation.
IQ241 sufficient capability for more complex strategies. It can • 12 digital inputs.
operate either as a stand alone device or as part of a Building • 8 analogue voltage outputs.
Management System. A standard Display Panel can be mounted • 10 slots for S cards (20 I/O points)
on the front cover, or externally. The IQ241 also has the facility to
connect any IQ system supervisor or Engineering Tool to the
network without a separate node controller.

Physical
230 Vac Input Power Knockouts for M20 cable gland
Knockout for RDS connector
Knockout for additional node RS232
(3.35”)
85 mm

24 V Input Power

I/O LEDs
325 mm
(12.8”)

S card fittings
under flap
V
1 3 5 7 9 1 1 1 3 1 5 1 7 1 9 2 1 2 3 2 5 2 7 2 9 3 1 3 3 3 5 3 7 3 9
2 4 6 1 0 1 2 1 4 1 6 1 2 0 2 2 2 4 2 6 2 3 0 3 2 3 4 3 6 3 4 0

LEDs TX RX

Channel identification label


1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 0
I1 d ig ita l in p u ts I1 2 I1 3 I2 0 I2 1 I3 2
S 1 a n a lo g u e in p u ts S 8 S 9 S 1 5
L 2 0 L 9 L 8 a n a lo g u e o u tp u ts L 1

LAN 1 C 3 C 5 C 7 C 9 C 11 C 13 C 15 C 17 C 19 C 21 C 23 C 25 C 27 C 29 C 31 C 33 C 35 C 37 C 39 C AUX
24v
2 C 4 C 6 C 8 C 10 C 12 C 14 C 16 C 18 C 20 C 22 C 24 C 26 C 28 C 30 C 32 C 34 C 36 C 38 C 40 C + - + -

Network connectors
Supervisor
I/O connectors port

Earthing (grounding)bar 355 mm (13.98”) Auxiliary supply

IQ241 Controller Data Sheet TA103013 Issue 2, 4/03/2009 1