The Optris CT LT is a precise non-contact temperature measurement device with a range of -50 °C to 975 °C and features a 22:1 optical resolution. It includes various output options, supports up to 32 sensors in one network, and has a rugged design suitable for high ambient temperatures. The device is equipped with separate electronics for easy programming and display, and offers optional interfaces for enhanced connectivity.

Uploaded by

shaik sohail
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views2 pages

Datasheet optris CT LT

The Optris CT LT is a precise non-contact temperature measurement device with a range of -50 °C to 975 °C and features a 22:1 optical resolution. It includes various output options, supports up to 32 sensors in one network, and has a rugged design suitable for high ambient temperatures. The device is equipped with separate electronics for easy programming and display, and offers optional interfaces for enhanced connectivity.

Uploaded by

shaik sohail
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

optris CT LT

TECHNICAL DATA

Precise non-contact Features:

temperature measurement • O
 ne of the smallest infrared sensors worldwide with 22:1
optical resolution
from –50 °C to 975 °C
• R
 ugged and usable up to 180 °C ambient temperature without
cooling
• Separate electronics with easy accessible programming keys
and LCD backlit display
• S
 electable analog output: 0/4 – 20 mA, 0 – 5 V, 0 – 10 V,
thermocouple type K or J
• O
 ptional USB, RS485, RS232 interface, relay outputs
(2 x optically isolated), Profibus DP, Ethernet
• Installation of up to 32 sensors in one network (with RS485)
• CTex: Explosion proof version (ATEX)

Measurement specifications
Temperature range –50 °C ... 975 °C (LT22)
General specifications (scalable via programming –50 °C ... 600 °C (LT15)
keys or software) –50 °C ... 600 °C (LT02)
Environmental rating IP 65 (NEMA-4)
Spectral range 8 – 14 μm
Ambient temperature1) –20 °C ... 180 °C (130°C to LT02) (sensing
head) Optical resolution 22:1 (precision glass optics)
–20 °C ... 85 °C (electronics) (90 % energy) 15:1 (precision glass optics)
2:1 (with flat front window)
Storage temperature – 40 °C ... 130 °C (sensing head)
– 40 °C ... 85 °C (electronics) CF-lens (optional) 0.6 mm @ 10 mm (with LT22)
0.8 mm @ 10 mm (with LT15)
Relative humidity 10 – 95 %, non condensing 2.5 mm @ 23 mm (with LT02)
Vibration (sensor) IEC 60068-2-6 (sinus shaped) System accuracy 2), 3) ±1 % or ±1 °C
IEC 60068-2-64 (broadband noise) (at ambient temp. 23 ±5 °C)
Shock (sensor) IEC 60068-2-27 (25G and 50G) Repeatability 2), 3) ±0.5 % or ±0.5 °C
(at ambient temp. 23 ±5 °C)
Weight 40 g (sensing head) / 420 g (electronics)
Temperature resolution 0.1 K
Electrical Specifications (display)
Outputs / analog Channel 1:0 / 4 – 20 mA, 0 – 5 / 10 V, thermocouple
NETD 3), 4) 0.05 K (LT22 / LT15)
J, K
0.1 K (LT02)
Channel 2: sensind head temperature (–20 °C ...
180 °C as 0 – 5 V or 0 – 10 V), alarm output Response time 150 ms (95 %)
Output / alarm 24 V / 50 mA (open collector) Emissivity/ Gain 0.100 – 1.100
(adjustable via programming
Optional Relay: 2 x 60 V DC/ 42 V ACeff; 0.4 A;
keys or software)
optically isolated
Transmissivity/ Gain 0.100 – 1.100
Outputs / digital (optional) USB, RS232, RS485, Profibus DP, Ethernet
(adjustable via programming
Output impedances mA max. 500 Ω (with 8 – 36 V DC) keys or software)
mV min. 100 kΩ load impedance
thermocouple 20 Ω Signal processing (parameter Peak hold, valley hold, average; extended hold func-
adjustable via programming tion with threshold and hysteresis
Inputs Programmable functional inputs for external keys or software, respectively)
emissivity adjustment, ambient temperature
compensation, trigger (reset of hold functions) Software optris Compact Connect
1) The LCD displays capacity may be limited at ambient temperatures below 0 °C
Cable length 1 m (standard), 3 m, 8 m, 15 m
2) Whichever is greater
Power Supply 8 – 36 V DC 3) At object temperatures >0 °C, ε = 1

4) At time constant 200 ms and T


Current draw Max. 100 mA Obj 25 °C

Optris GmbH · Ferdinand-Buisson-Str. 14 · 13127 Berlin · Germany


Phone: +49 30 500 197-0 · Fax: +49 30 500 197-10 · E-mail: [email protected] · www.optris.global
optris CT LT

Optical specifications

Optics CT LT SF, D:S = 2:1 Optics CT LT CF, D:S = 2:1 (far field = 2.5:1)

S 5 53.8 102.5 151.3 200 251.3 302.5 353.8 405 (mm) S 7 5 3.1 2.5 5.4 9.5 13.7 17.8 (mm)

D 0 100 200 300 400 500 600 700 800 (mm) D 0 10 20 23 30 40 50 60 (mm)

Optics CT LT SF, D:S = 15:1 Optics CT LT CF, D:S = 15:1 (far field = 1.5:1)

S 6.5 11.6 16.6 21.7 26.7 35 43.3 51.6 59.9 68.2 76.5 (mm) S 7 3.9 0.8 4.7 8.6 12.5 16.4 20.3 24.2 (mm)
D 0 100 200 300 400 500 600 700 800 900 1000 (mm) D 0 5 10 15 20 25 30 35 40 (mm)

Optics CT LT CF, D:S = 22:1 (far field = 1.5:1)


Optics CT LT SF, D:S = 22:1

S 6.5 10.9 15.2 19.6 23.9 28.3 32.6 37 41.3 45.7 50 (mm) S 7 3.8 0.6 4.4 8.2 12 15.8 19.6 23.4 (mm)
D 0 110 220 330 440 550 660 770 880 990 1100 (mm) D 0 5 10 15 20 25 30 35 40 (mm)

Versions with built-in CF lenses, head length: 32 mm


Optics CT LT CF, D:S = 15:1 (far field: 5:1) Optics CT LT CF, D:S = 22:1 (far field = 1.5:1)

S 6.5 5 4 3.4 5.4 8.4 13.3 18.3 23.2 28.2 33.1 (mm) S 6.5 4.4 3.2 2.3 4.1 6.7 11.1 15.5 19.9 24.3 28.7 (mm)

Specifications are subject to change without notice · CT LT-DS-EN2018-07-B


D 0 25 40 50 60 75 100 125 150 175 200 (mm) D 0 25 40 50 60 75 100 125 150 175 200 (mm)

Dimensions

Sensing head Electronics


(standard)

Sensing head
(built-in CF
lenses)