0% found this document useful (0 votes)
22 views1 page

Mahabubur Rahaman Approval

The document contains architectural plans for a proposed G+2 storied residential building, including various elevations, floor plans, and structural details. It specifies measurements for different sections, such as rooms, staircases, and entry ramps, along with details on materials and construction elements. Additionally, it includes information on lightning arrestors and height indicators relevant to the building's design.

Uploaded by

mehadimahmudmoon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
22 views1 page

Mahabubur Rahaman Approval

The document contains architectural plans for a proposed G+2 storied residential building, including various elevations, floor plans, and structural details. It specifies measurements for different sections, such as rooms, staircases, and entry ramps, along with details on materials and construction elements. Additionally, it includes information on lightning arrestors and height indicators relevant to the building's design.

Uploaded by

mehadimahmudmoon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ABDUR RAZZAK A B C D

LIGHTNING HEIGHT INDICATOR


ARRESTOR LIGHT 3.03m 3.51m 4.50m
15.85m

2.29m
1.00m

1.00m

0.91m
1.51m 3.00m
1
GB GB GB

ROOF LEVEL

3.87m

GB

GB
3.05m

GB
GB
GB
2

3.00m WIDE ROAD

3.00m WIDE ROAD


2ND FLOOR LEVEL

1.42m
12.80m
13.11m
PROPOSED G+2 STORIED STAIR & U.G.W.T GB GB
3

GB

GB
RESIDENTIAL BUILDING

3.05m

1.40m
GB
4
1ST FLOOR LEVEL

GB

GB
3.05m

3.87m

GB

GB
ENTRY/EXIT
RAMP

PL LEVEL GB GB GB
1.51m 3.00m 5

1.00m
0.0m ROAD LEVEL

1.22m

0.61m
EAST ELEVATION
SCALE = 1:100
15.85m

N
ROOF FLOOR PLAN TAHOMINA
LIGHTNING HEIGHT INDICATOR

NW

NE
W

E
SE

SCALE = 1:100

SW
S

ARRESTOR LIGHT
N
GRADE BEAM LAYOUT PLAN

NW

NE
W

E
SCALE = 1:100

SW

SE
S

2.29m
15.85m

0.91m
1 3 5

1.00m

1.00m
3.00m 2- 16mm Ø Bar ST 2- 16mm Ø Bar ST
ROOF LEVEL
1.70m
KITCHEN
1.37m 1 1' 1 1 1' 1
TOILET
3.08m 4.55m
PROPOSED

2.04m

1.98m
2.04mX1.70m 1.98mX1.37m

3.05m
BED ROOM BED ROOM 1 1' 1 1 1' 1 1148
1149,1150, SITE

3.89m

3.96m
3.89mX3.08m 3.96mX4.55m
2-16mmØ Bar ST 2-16mmØ Bar ST 1152,1153
10mm Ø @ 100mm~175mm~100mm C/C 10mm Ø @ 100mm~175mm~100mm C/C
2ND FLOOR LEVEL L/4 5L/12 L/3 L/3 5L/12 L/4
3.20m
DRAWING & DINING 1.24m. 2.07m. 1.66m. 1.66m. 2.07m. 1.25m.

3.13m
3.13mX3.20m 4.97m. 4.97m.

3.05m
A A

3.00m WIDE ROAD

3.00m WIDE ROAD


TOILET
2.44m GRADE BEAM LONG SECTION Gri - A B

1.22m

DN
1.22mX2.44m

12.80m
4.55mX2.44m
13.11m

STAIR
2.44m
4.55m MOUZA NAME - SRI BARI

A B C D N

MOUZA MAP

NE
NW

UP

E
1ST FLOOR LEVEL SCALE = 1:200

SW

SE
S

1.51m
2- 16mm Ø Bar ST 2- 16mm Ø Bar ST 2- 16mm Ø Bar ST

3.05m
1 1' 1 1 1' 1 1 1' 1

10mmBar @ 125mm C/C

ENTRY/EXIT
1 1' 1 1 1' 1 1 1' 1
10mmBar @ 125 C/C
RAMP PL LEVEL 2-16mmØ Bar ST 2-16mmØ Bar ST 2-16mmØ Bar ST
0.0m ROAD LEVEL 10mm Ø @ 100mm~175mm~100mm C/C 10mm Ø @ 100mm~175mm~100mm C/C 10mm Ø @ 100mm~175mm~100mm C/C
L/4 5L/12 L/3 L/3 L/3 L/3 L/3 5L/12 L/4

0.61m
WEST ELEVATION 0.68m. 1.14m. 0.91m. 1.08m. 1.07m. 1.07m. 1.41m. 1.75m. 1.05m.
SCALE = 1:100 2.73m. 3.21m. 4.21m.

0.18m.
12mmBar @ 125mm C/C 12mmBar @ 125mm C/C

1.00m
1.22m

GRADE BEAM LONG SECTION Gri - 1&5.


10mmBar @ 150mm C/C 10mmBar @ 150mm C/C

2.44m.
HEIGHT INDICATOR LIGHTNING
15.85m LIGHT ARRESTOR
0.25m 0.25m 12mmBar @ 6" C/C

0.30m.
N
GROUND FLOOR PLAN 2-16mm Ø Bar ST 2-16mm Ø Bar ST 0.30m.
NE

NW

16mmBar @ 6" C/C

1'
2.29m
W

SCALE = 1:100
SW

SE

0.31m

0.31m
0.91m
10mm Ø stirrup 10mm Ø stirrup
@ 100mm C/C @ 175mm C/C

0.08m.
15.85m SECTION X-X
ROOF LEVEL
0.25m 0.25m
2-16mm Ø Bar ST 2-16mm Ø Bar ST
1.00m

1.00m
3.86m
3.00m (GB) SECTION 1-1 (GB) SECTION 1'-1'

3.05m

0.25m
GRADE BEAM (GB)

0.25m
1.37m
1.70m
KITCHEN TOILET
3.08m 4.55m
2.04m

1.98m

2.04mX1.70m 1.98mX1.37m

BED ROOM BED ROOM 2ND FLOOR LEVEL


1 3 5
3.89m

3.96m

3.89mX3.08m 3.96mX4.55m

2- 16mm Ø Bar ST

3.05m

3.96m
3.20m 1- 12mmØ (Ext)
3.13m

DRAWING & DINING 1 1' 1 1 1' 1


3.13mX3.20m
A A
3.00m WIDE ROAD

3.00m WIDE ROAD


TOILET
2.44m
1.22m

DN

1.22mX2.44m 1ST FLOOR LEVEL 1 1' 1 1 1' 1 Man Hole Man Hole

12.80m
4.55mX2.44m
13.11m

2-16mmØ Bar ST 2-16mmØ Bar ST


STAIR
2.44m

4.55m
1-12mmØ(Ext) 1-12mmØ(Ext)
TOILET

3.05m
2.44m 10mm Ø @ 100mm~175mm~100mm C/C 10mm Ø @ 100mm~175mm~100mm C/C
1.22m

UP

1.22mX2.44m
L/4 5L/12 L/3 L/3 5L/12 L/4
DRAWING & DINING 1.24m. 2.07m. 1.66m. 1.66m. 2.07m. 1.25m.
3.13m

3.13mX3.20m 4.97m. 4.97m.


3.20m
FLOOR BEAM LONG SECTION Gri - A B 1.78m 1.78m
1.51m PL LEVEL
0.25m 0.3m 0.25m
0.0m ROAD LEVEL
3.96m
3.89m

BED ROOM BED ROOM

0.61m
3.89mX3.08m 3.96mX4.55m SOUTH ELEVATION A B C D UNDER GROUND
SCALE = 1:100
1.98m
2.04m

3.08m
KITCHEN TOILET
1.98mX1.37m
4.55m WATER RESERVOIR
2.04mX1.70m
1.70m
1.37m 2- 16mm Ø Bar ST 2- 16mm Ø Bar ST DETAILS
1- 12mmØ (Ext) 1- 12mmØ (Ext)
LIGHTNING HEIGHT INDICATOR 1 1' 1 1 1' 1 1 1' 1

0.18m.
1.00m

10mm Ø Bar @ 5" C/C

0.18m.
1.22m

ARRESTOR LIGHT 10mm Ø Bar @ 5" C/C

1 1' 1 1 1' 1 1 1' 1


15.85m

2.29m
2-16mmØ Bar ST INLET
1-12mmØ(Ext) OUTLET

1.14m.
10mm Ø @ 100mm~175mm~100mm C/C
TYPICAL FLOOR PLAN
0.91m
N 10mm Ø @ 100mm~175mm~100mm C/C 10mm Ø @ 100mm~175mm~100mm C/C
NW

NE

L/3 5L/12 L/4


W

L/4 5L/12 L/3 L/3 L/3 L/3


E

SCALE = 1:100
SW

SE

2.62m.
0.68m. 1.14m. 0.91m. 1.08m. 1.07m. 1.07m. 1.41m. 1.75m. 1.05m.

2.44m.
2.92m.
2.73m. 3.21m. 4.21m.

2.16m.

2.01m.

2.01m.

2.01m.

0.61m.
ROOF LEVEL FLOOR BEAM LONG SECTION Gri - 1&5.

0.69m.
15.85m 0.25m 0.25m 12mm Ø Bar @ 6" C/C

0.30m.
3.05m

2-16mm Ø Bar ST 2-16mm Ø Bar ST 12mm Ø Bar @ 6" C/C


1- 12mmØ Ext
1.00m

1.00m

0.31m

0.31m
3.00m

0.30m.
SLO
1:200
SLOPE
2ND FLOOR LEVEL 10mm Ø stirrup 10mm Ø stirrup SECTION X-X
P E 1:2
@ 175mm C/C
SLO

00 @ 100mm C/C

0.25m
APPROVAL DRAWING
SLOPE

0.25m 0.25m 0.25m 0.25m 0.25m


P E 1:2

0.25m 1.3m 1.17m 1.3m


1:200

00

3.05m

2-16mm Ø Bar ST 2-16mm Ø Bar ST


1-12mmØ Ext PROJECT

1.22m
(FB) SECTION 1-1

0.25m
(FB) SECTION 1'-1' 24" Ø Man Hole 24" Ø Man Hole 24" Ø Man Hole

1.02m
1ST FLOOR LEVEL
FLOOR BEAM (FB) PROPOSED G+2 STORIED
X INLET OUTLET X
RESIDENTIAL BUILDING AT

0.81m
A A
3.00m WIDE ROAD

3.00m WIDE ROAD

3.05m
DN

12.80m
4.55mX2.44m

MANIKGANJ
13.11m

STAIR
2.44m

4.55m
A B C D
4.27m
UP

3.03m 3.51m 4.50m


PL LEVEL 0.25m 0.25m 0.25m 0.25m
1.51m
SEPTIC TANK PLAN LOCATION
0.0m ROAD LEVEL
0.61m

NORTH ELEVATION
SCALE = 1:100
1 J.L NO.-97,

0.15m.
10mm Bar @ 125mm C/C

Khatian no-R.S-2145
00
00

HEIGHT INDICATOR LIGHTNING


P E 1:2
P E 1:2

12mm Bar @ 100mm C/C


LIGHT ARRESTOR
Mouza- Sri Bari
SLO

12mm Bar @ 100mm C/C


SLO

(A)
3.87m

1.52m.
1:200
1:200
SLOPE OVER HEAD
SLOPE WATER TANK
Dag No.- 1149,1150,1152,1153
2.29m

10mm Bar @ 125mm C/C

0.15m.
1.00m

Khariz :- 2277
1.22m

0.91m

2.90m.
15.85m 2 12mm Bar @ 100mm C/C
12mm Bar @ 100mm C/C P.S-Ghior
10mm Bar @ 125mm C/C
District- Manikganj,Bangladesh.

(B)

(B)
1.42m

ROOF LEVEL

0.15m.
0.25m.
N
ROOF FLOOR PLAN
NW

NE
W

1.52m.
E

0.15m.
SCALE = 1:100 3
SW

SE

10mm Bar @ 125mm C/C

2.90m.
3.05m

1.40m

A B C D 12mm Bar @ 100mm C/C


12mm Bar @ 100mm C/C
0.38m.
3.03m 3.51m 4.50m 4
1.22m.
2ND FLOOR LEVEL AREA

0.15m.
10mm Bar @ 125mm C/C

2.90m.
TOTAL LAND = 205.31 Sqm.
3.87m
0.15m

0.15m

0.15m

0.15m

0.15m 0.15m 0.15m 0.15m


(A) 12mm Bar @ 100mm C/C
3.05m

12mm Bar @ 100mm C/C


1

3.05m

6"
0.15m

0.15m

0.15m

0.15m

FLOOR

0.15m.
RESIDENTIAL

1.37m.
0.15m 0.15m 0.15m 0.15m
C1 C1 C1 C1 0.25m.

0.15m.
1.52m.
10mm Bar @ 125mm C/C
1ST FLOOR LEVEL 5 123.15 sqm X 1
3.87m

GROUND FLOOR

0.60m.
12mm Bar @ 100mm C/C
STAIR DETAIL
3.05m

1ST -2ND FLOOR 123.15 sqm X 2


0.19m

0.11m

0.15m
0.15m

2
0.19m

0.19m
1.42m

0.15m 0.23m
C2 C2 (A) = 10mmØ Bar @ 150 mm C/C alt ckd
PL LEVEL N
FLOOR BEAM LAYOUT PLAN (B) = 10mmØ Bar @ 150mm C/C CHILEKOTHA 12.9 sqm
NW

NE
0.16m

0.19m

0.23m 0.15m
W

SCALE = 1:100
SW

SE

3
S

0.0m ROAD LEVEL SLAB THICKNESS = 125mm


0.15m

0.19m

0.15m
C2
1.40m

0.15m
C2 Total build area
0.61m

SECTION AA 382.35 sqm


0.19m
0.19m

0.15m 0.15m
SCALE = 1:100
4
ARCHITECTS NAME:
0.11m
0.19m

0.23m
0.15m
C2 C2
A B C D One Layer 10mm Ø Bar @125mm C/C

3.03m 3.51m 4.50m


FOOTING SCHEDULE :
3.87m

0.09m.
0.76m 0.76m 0.76m 0.76m 0.76m 0.76m 0.76m 0.76m
DEPTH REINFORCEMENT REINFORCEMENT FALSE DETAILS
0.76m 0.76m

0.76m 0.76m

0.76m 0.76m

0.76m 0.76m

TYPE T L B
(D)
0.15m

0.15m

0.15m

0.15m

(SHORT DIRECTION BAR) (LONG DIRECTION BAR)


1.52m

1.52m

1.52m

1.52m

0.15m 0.15m 0.15m 0.15m


2-12mm Ø ST
5 1 0.15m.
0.15m

0.15m

0.15m

0.15m

0.15m 0.15m 0.15m 0.15m F1 F1 F1 F1


C1 C1 C1 C1

0.15m.
1.52m 1.52m 1.52m 1.52m
F1 2.43m .48m 1.3m 1.3m 16mm @ 152mm C/C 16mm @ 152mm C/C 8mm Ø stirrup @ 150mm C/C
3.87m

2-12 mm Ø ST

1.07m 1.07m 1.10m 1.03m F2 2.43m .48m 2.44m 2.44m 16mm @ 152mm C/C 16mm @ 152mm C/C LINTEL DETAILS
1.07m

COLUMN LAYOUT PLAN


1.03m

ENGINEERS NAME:
N
NW

NE
W

SCALE = 1:100
2.13m

2.13m
SW

SE

2
S

1.03m 1.10m 1.07m 1.07m


1.07m

1.10m
1.42m

1.07m

1.07m

F2 F2
COLUMN SCHEDULE
2.13m

2.13m

2.13m 2.13m
3 1.07m 1.07m 1.10m 1.03m
COLUMN 38mm Clear cover
1.06m

1.07m
1.40m

FLOOR LEVEL
BELOW GF ABOVE GF - REST
1.10m

ID
1.07m

F2 F2
2.13m
2.13m

G.B
8-16mmØ 8-16mmØ 4 2.13m 2.13m
E. G. L E.G.L
1.03m
1.07m

0.38m 0.30m F2 F2
2.13m 2.13m
0.38m

0.30m

75mm Clear cover

C1
3.87m

76mm 38mm
X X

a
DF

10mmØ Ring 10mmØ Ring


@ 100mm~150mm~100mm C/C @ 100mm~150mm~100mm C/C 0.76m 0.76m 0.76m 0.76m 0.76m 0.76m 0.76m 0.76m
B
0.76m 0.76m

0.76m 0.76m

0.76m 0.76m

0.76m 0.76m

OWNERS NAME AND SIGNATURE:


1.52m

1.52m

1.52m

1.52m

14-16mmØ 14-16mmØ 5
75mm
T

F1 F1 F1 F1 b
0.46m 0.38m B.F.S
1.52m 1.52m 1.52m 1.52m

C2 L
1m

SAND FILLING
0.38m

0.30m

76mm 38mm
L
SECTION OF X.X
PLAN OF FOOTING

10mmØ Ring 10mmØ Ring


@ 100mm~150mm~100mm C/C @ 100mm~150mm~100mm C/C N
FOOTING LAYOUT PLAN MD. MAHABUBUR RAHMAN
NW

NE
W

SCALE = 1:100
SW

SE