0% found this document useful (0 votes)
4 views

WWW

The document contains architectural plans for a mixed-use building, detailing the ground, second, third, and fourth floor layouts. It includes specifications for various areas such as bedrooms, living spaces, kitchens, and service areas, along with compliance notes regarding architectural regulations. The plans are associated with Holy Angel University and include the names of students involved in the project.

Uploaded by

qfg2qqcf42
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4 views

WWW

The document contains architectural plans for a mixed-use building, detailing the ground, second, third, and fourth floor layouts. It includes specifications for various areas such as bedrooms, living spaces, kitchens, and service areas, along with compliance notes regarding architectural regulations. The plans are associated with Holy Angel University and include the names of students involved in the project.

Uploaded by

qfg2qqcf42
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

A B C D E F

37.58
28.00

2.49 4.32 3.35 2.00 4.33 4.13 2.05 3.35 4.27 A B C D E F

28.00

3.58 4.32 3.35 2.00 4.33 4.13 2.05 3.35 4.27 3.78

1 1
BEDROOM 1 BEDROOM 1 BEDROOM 1 BEDROOM 1
1.85

1.85

1.85

1.85
BALCONY BALCONY BALCONY BALCONY
T&B T&B T&B T&B T&B T&B T&B T&B

CL

CL

CL

CL

1.23
1.50
KITCHEN & DINING KITCHEN & DINING KITCHEN & DINING KITCHEN & DINING

LAU

LAU

LAU

LAU
MASTER AREA AREA MASTER MASTER AREA AREA MASTER
5.95

5.95

5.95
BEDROOM LIVING LIVING BEDROOM BEDROOM LIVING LIVING BEDROOM

REF

REF

REF

REF
AREA AREA AREA AREA

3.22
WALK-IN WALK-IN WALK-IN WALK-IN
CLOSET CLOSET CLOSET CLOSET

2 2

1.10
1.16
RAMP RAMP
DN
SECONDARY DN
ELEVATOR
2.66

2.66
UP FIRE EXIT & RESIDENTIAL AREA ENTRANCE / FIRE UP SERVICE RESIDENTIAL AREA ELEVATOR
HALLWAY AREA FIRE EXIT FIRE EXIT

1.28

1.40
EXIT AREA & STAIRS HALLWAY AREA
20.00

20.00

20.00

20.00
STAIRS STAIRS
DN DN
2 1
1 2

UP 8 7 6 5 4 3 2 1 17 1 UP 8 7 6 5 4 3 2 1 1 17

16 2 2 16
UP UP
17 1 15 3 17 1 3 15
16 2 14 4 16 2 4 14
15 3
FRONT DESK STORAGE 9 13 5 15 3
FRONT DESK STORAGE 9
SERVICE 5 13

3.28

3.22
14 4 12 6 14 4 6 12
3.57

3.57
13 5 ROOM 11 7 13 5 ROOM STAIRS 7 11
12 6 8 12 6 8
11 7 10 11 12 13 14 15 16 17 11 7 10 11 12 13 14 15 16 17

3 8
3 8

10 9 9 10

0.51
32.50

32.50
10 9 10 9

T&B T&B

2.61
2.86

2.86

2.86
ELEVATOR ELEVATOR
WORKSHOP / WORKSHOP /
AREA AREA
COMMERCIAL COMMERCIAL
SPACE SPACE

3.47
LOBBY
2.91

2.91

2.91
LOBBY

4 4

1.14 1.14 0.96 8.35 19.45 1.10 2.68


0.28 28.00
6.45

6.45
MAIN ENTRANCE

RAMP UP RAMP
UP UP
4.05

4.05
2.79 1.71 4.46 1.83 14.17 2.65
28.00
37.58

MIXED-USE BUILDING MIXED-USE BUILDING


1 GROUND FLOOR PLAN 2 SECOND FLOOR PLAN
A.01 SCALE - 1:225 MTS A.01 SCALE - 1:225 MTS

REPUBLIC ACT 9266


UNIVERSITY & DEPARTMENT ARTICLE III SECTION 20 (5):
PLATE TITLE & SECTION NAME OF STUDENT/S SHEET CONTENTS SHEET NO.
ALL ARCHITECTURAL DRAWINGS, PLANS, DESIGNS, SPECIFICATIONS AND
ARCHITECTURAL DOCUMENTS RELATIVE TO THE CONSTRUCTION OF A
BUILDING SHALL BEAR THE SEAL AND SIGNATURE ONLY OF AN ARCHITECT
REGISTERED AND LICENSED UNDER THE ACT.

HOLY ANGEL UNIVERSITY


SCHOOL OF ENGINEERING AND ARCHITECTURE
ARTICLE IV SECTION 33;
DRAWINGS AND SPECIFICATIONS DULY SIGNED, STAMP OR SEALED AS
INSTRUMENT OF SERVICES ARE INTELLECTUAL PROPERTIES AND
DOCUMENTS OF THE ARCHITECT.

REPUBLIC ACT 8293 SECTION 186:


WATER SUPPLY AND
DRAINAGE SYSTEMS
ME - 401
AARON WILL G. CALBANG
EZECHIEL S. HENZON
GROUND FLOOR PLAN
SECOND FLOOR PLAN A.01
INTELLECTUAL PROPERTY LAW : COPYRIGHT IN THE ARCHITECTURAL
WORKS OF AN ARCHITECT SHALL INCLUDE AND HAS RIGHT TO CONTROL ALL
DRAWINGS. DRAWN: 12/30/24
A B C D E F A B C D E F

28.00 28.00
3.58 4.32 3.35 2.00 4.33 4.13 2.05 3.35 4.27 3.78 3.58 4.32 3.35 2.00 4.33 4.13 2.05 3.35 4.27 3.78

1 1
BEDROOM 1 BEDROOM 1 BEDROOM 1 BEDROOM 1
1.85

1.85

1.85

1.85
BALCONY BALCONY BALCONY BALCONY
T&B T&B T&B T&B T&B T&B T&B T&B

CL

CL

CL

CL
1.23

1.23
1.50

1.50
KITCHEN & DINING KITCHEN & DINING KITCHEN & DINING KITCHEN & DINING

LAU

LAU

LAU

LAU
MASTER AREA AREA MASTER MASTER AREA AREA MASTER
5.95

5.95
BEDROOM LIVING LIVING BEDROOM BEDROOM LIVING LIVING BEDROOM

REF

REF

REF

REF
AREA AREA AREA AREA

3.22

3.22
WALK-IN WALK-IN WALK-IN WALK-IN
CLOSET CLOSET CLOSET CLOSET

2 2

1.10
1.16

1.10
1.16
SERVICE RESIDENTIAL AREA ELEVATOR SERVICE RESIDENTIAL AREA ELEVATOR
FIRE EXIT FIRE EXIT FIRE EXIT FIRE EXIT
1.28

1.40
AREA

1.28

1.40
HALLWAY HALLWAY AREA
20.00

20.00

20.00

20.00
STAIRS STAIRS
DN DN DN DN
17 1 UP 8 7 6 5 4 3 2 1 1 17 17 1 DN 10 11 12 13 14 15 16 17 1 17
16 2 2 16 16 2 2 16
15
UP 15
3 17 1 3 15 3 1 17 3 15
14 4 16 2 4 14 14 4 2 16 SERVICE 4 14
13 5 15 3
FRONT DESK STORAGE 9
SERVICE 5 13
FRONT DESK STORAGE 9
3.28

13 5 3 5 13

3.22
15

3.28

3.22
12 6 14 4 6 12 12 6 4 14 STAIRS 6 12
11 7 13 5 ROOM STAIRS 7 11 11 7 5 13 ROOM DN
7 11
8 12 6 8 8 6 12 8
11 7 10 11 12 13 14 15 16 17 7 11 8 7 6 5 4 3 2 1

3 8
3 10

10 9 9 10 10 9 9 10
0.51

0.51
10 9 8 9

T&B T&B

2.61

2.61
2.86

2.86
ELEVATOR ELEVATOR
WORKSHOP / WORKSHOP /
AREA AREA
COMMERCIAL COMMERCIAL
SPACE SPACE

3.47

3.47
2.91

2.91
LOBBY LOBBY

4 4

1.14 1.14 0.96 8.35 19.45 1.10 2.68 1.14 1.14 0.96 8.35 19.45 1.10 2.68
0.28 28.00 0.28 28.00

MIXED-USE BUILDING MIXED-USE BUILDING


1 THIRD FLOOR PLAN 2 FOURTH FLOOR PLAN
A.02 SCALE - 1:225 MTS A.02 SCALE - 1:225 MTS

REPUBLIC ACT 9266


UNIVERSITY & DEPARTMENT ARTICLE III SECTION 20 (5):
PLATE TITLE & SECTION NAME OF STUDENT/S SHEET CONTENTS SHEET NO.
ALL ARCHITECTURAL DRAWINGS, PLANS, DESIGNS, SPECIFICATIONS AND
ARCHITECTURAL DOCUMENTS RELATIVE TO THE CONSTRUCTION OF A
BUILDING SHALL BEAR THE SEAL AND SIGNATURE ONLY OF AN ARCHITECT
REGISTERED AND LICENSED UNDER THE ACT.

HOLY ANGEL UNIVERSITY


SCHOOL OF ENGINEERING AND ARCHITECTURE
ARTICLE IV SECTION 33;
DRAWINGS AND SPECIFICATIONS DULY SIGNED, STAMP OR SEALED AS
INSTRUMENT OF SERVICES ARE INTELLECTUAL PROPERTIES AND
DOCUMENTS OF THE ARCHITECT.

REPUBLIC ACT 8293 SECTION 186:


WATER SUPPLY AND
DRAINAGE SYSTEMS
ME - 401
AARON WILL G. CALBANG
EZECHIEL S. HENZON
THIRD FLOOR PLAN
FOURTH FLOOR PLAN A.02
INTELLECTUAL PROPERTY LAW : COPYRIGHT IN THE ARCHITECTURAL
WORKS OF AN ARCHITECT SHALL INCLUDE AND HAS RIGHT TO CONTROL ALL
DRAWINGS. DRAWN: 12/30/24

You might also like