0% found this document useful (0 votes)
11 views

Red_Hat_Enterprise_Linux-8-Configuring_and_managing_high_availability_clusters-en-US

This document serves as a guide for installing, configuring, and managing the Red Hat High Availability Add-On for Red Hat Enterprise Linux 8. It covers various topics including Pacemaker architecture, fencing, quorum, resource management, and specific configurations for services like Apache and NFS in a high availability cluster. The document also provides detailed instructions and best practices for creating and managing high availability clusters.

Uploaded by

abrar.jalali
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views

Red_Hat_Enterprise_Linux-8-Configuring_and_managing_high_availability_clusters-en-US

This document serves as a guide for installing, configuring, and managing the Red Hat High Availability Add-On for Red Hat Enterprise Linux 8. It covers various topics including Pacemaker architecture, fencing, quorum, resource management, and specific configurations for services like Apache and NFS in a high availability cluster. The document also provides detailed instructions and best practices for creating and managing high availability clusters.

Uploaded by

abrar.jalali
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 161

Red Hat Enterprise Linux 8

Configuring and managing high availability


clusters

Configuring and managing the Red Hat High Availability Add-On

Last Updated: 2019-08-21


Red Hat Enterprise Linux 8 Configuring and managing high availability
clusters
Configuring and managing the Red Hat High Availability Add-On
Legal Notice
Copyright © 2019 Red Hat, Inc.

The text of and illustrations in this document are licensed by Red Hat under a Creative Commons
Attribution–Share Alike 3.0 Unported license ("CC-BY-SA"). An explanation of CC-BY-SA is
available at
http://creativecommons.org/licenses/by-sa/3.0/
. In accordance with CC-BY-SA, if you distribute this document or an adaptation of it, you must
provide the URL for the original version.

Red Hat, as the licensor of this document, waives the right to enforce, and agrees not to assert,
Section 4d of CC-BY-SA to the fullest extent permitted by applicable law.

Red Hat, Red Hat Enterprise Linux, the Shadowman logo, the Red Hat logo, JBoss, OpenShift,
Fedora, the Infinity logo, and RHCE are trademarks of Red Hat, Inc., registered in the United States
and other countries.

Linux ® is the registered trademark of Linus Torvalds in the United States and other countries.

Java ® is a registered trademark of Oracle and/or its affiliates.

XFS ® is a trademark of Silicon Graphics International Corp. or its subsidiaries in the United States
and/or other countries.

MySQL ® is a registered trademark of MySQL AB in the United States, the European Union and
other countries.

Node.js ® is an official trademark of Joyent. Red Hat is not formally related to or endorsed by the
official Joyent Node.js open source or commercial project.

The OpenStack ® Word Mark and OpenStack logo are either registered trademarks/service marks
or trademarks/service marks of the OpenStack Foundation, in the United States and other
countries and are used with the OpenStack Foundation's permission. We are not affiliated with,
endorsed or sponsored by the OpenStack Foundation, or the OpenStack community.

All other trademarks are the property of their respective owners.

Abstract
This guide provides information about installing, configuring, and managing the Red Hat High
Availability Add-On for Red Hat Enterprise Linux 8.
Table of Contents

Table of Contents
. . . . . . . . . . . . . FEEDBACK
PROVIDING . . . . . . . . . . . . ON
. . . .RED
. . . . .HAT
. . . . .DOCUMENTATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7. . . . . . . . . . . . .

.CHAPTER
. . . . . . . . . . 1.. .HIGH
. . . . . .AVAILABILITY
. . . . . . . . . . . . . . .ADD-ON
. . . . . . . . . .OVERVIEW
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8. . . . . . . . . . . . .
1.1. HIGH AVAILABILITY ADD-ON COMPONENTS 8
1.2. PACEMAKER OVERVIEW 8
1.2.1. Pacemaker architecture components 8
1.2.2. Configuration and management tools 9
1.2.3. The cluster and pacemaker configuration files 10
1.3. FENCING OVERVIEW 10
1.4. QUORUM OVERVIEW 10
1.5. RESOURCE OVERVIEW 11
1.6. LVM LOGICAL VOLUMES IN A RED HAT HIGH AVAILABILITY CLUSTER 11
1.6.1. Choosing HA-LVM or shared volumes 11
1.6.2. Configuring LVM volumes in a cluster 12

.CHAPTER
. . . . . . . . . . 2.
. . GETTING
. . . . . . . . . . .STARTED
. . . . . . . . . .WITH
. . . . . .PACEMAKER
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
..............
2.1. LEARNING TO USE PACEMAKER 13
2.2. LEARNING TO CONFIGURE FAILOVER 17

.CHAPTER
. . . . . . . . . . 3.
. . THE
. . . . . PCS
. . . . . COMMAND
. . . . . . . . . . . . LINE
. . . . . .INTERFACE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
..............
3.1. PCS HELP DISPLAY 22
3.2. VIEWING THE RAW CLUSTER CONFIGURATION 22
3.3. SAVING A CONFIGURATION CHANGE TO A WORKING FILE 22
3.4. DISPLAYING CLUSTER STATUS 23
3.5. DISPLAYING THE FULL CLUSTER CONFIGURATION 23

.CHAPTER
. . . . . . . . . . 4.
. . .CREATING
. . . . . . . . . . .A
. . RED
. . . . .HAT
. . . . .HIGH-AVAILABILITY
. . . . . . . . . . . . . . . . . . . . . .CLUSTER
. . . . . . . . . .WITH
. . . . . .PACEMAKER
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
..............
4.1. INSTALLING CLUSTER SOFTWARE 24
4.2. CREATING A HIGH AVAILABILITY CLUSTER 26
4.3. CREATING A HIGH AVAILABILITY CLUSTER WITH MULTIPLE LINKS 26
4.4. CONFIGURING FENCING 27
4.5. BACKING UP AND RESTORING A CLUSTER CONFIGURATION 28
4.6. ENABLING PORTS FOR THE HIGH AVAILABILITY ADD-ON 29

CHAPTER 5. CONFIGURING AN ACTIVE/PASSIVE APACHE HTTP SERVER IN A RED HAT HIGH


. . . . . . . . . . . . . . . .CLUSTER
AVAILABILITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
..............
5.1. CONFIGURING AN LVM VOLUME WITH AN EXT4 FILE SYSTEM IN A PACEMAKER CLUSTER 32
5.2. CONFIGURING AN APACHE HTTP SERVER 33
5.3. CREATING THE RESOURCES AND RESOURCE GROUPS 34
5.4. TESTING THE RESOURCE CONFIGURATION 36

CHAPTER 6. CONFIGURING AN ACTIVE/PASSIVE NFS SERVER IN A RED HAT HIGH AVAILABILITY


. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
CLUSTER ..............
6.1. PREREQUISITES 38
6.2. PROCEDURAL OVERVIEW 38
6.3. CONFIGURING AN LVM VOLUME WITH AN EXT4 FILE SYSTEM IN A PACEMAKER CLUSTER 38
6.4. CONFIGURING AN NFS SHARE 40
6.5. CONFIGURING THE RESOURCES AND RESOURCE GROUP FOR AN NFS SERVER IN A CLUSTER 40
6.6. TESTING THE NFS RESOURCE CONFIGURATION 44
6.6.1. Testing the NFS export 44
6.6.2. Testing for failover 44

. . . . . . . . . . . 7.
CHAPTER . . GFS2
. . . . . . .FILE
. . . . .SYSTEMS
. . . . . . . . . . IN
. . .A. .CLUSTER
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
..............

1
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

7.1. CONFIGURING A GFS2 FILE SYSTEM IN A CLUSTER 46


7.2. MIGRATING A GFS2 FILE SYSTEM FROM RHEL7 TO RHEL8 50

.CHAPTER
. . . . . . . . . . 8.
. . .CONFIGURING
. . . . . . . . . . . . . . . FENCING
. . . . . . . . . . .IN
..A
. . RED
. . . . . HAT
. . . . . HIGH
. . . . . . AVAILABILITY
. . . . . . . . . . . . . . . CLUSTER
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
..............
8.1. DISPLAYING AVAILABLE FENCE AGENTS AND THEIR OPTIONS 52
8.2. CREATING A FENCE DEVICE 53
8.3. GENERAL PROPERTIES OF FENCING DEVICES 53
8.4. ADVANCED FENCING CONFIGURATION OPTIONS 54
8.5. TESTING A FENCE DEVICE 59
8.6. CONFIGURING FENCING LEVELS 62
8.7. CONFIGURING FENCING FOR REDUNDANT POWER SUPPLIES 63
8.8. DISPLAYING CONFIGURED FENCE DEVICES 63
8.9. MODIFYING AND DELETING FENCE DEVICES 64
8.10. MANUALLY FENCING A CLUSTER NODE 64
8.11. DISABLING A FENCE DEVICE 64
8.12. PREVENTING A NODE FROM USING A FENCE DEVICE 64
8.13. CONFIGURING ACPI FOR USE WITH INTEGRATED FENCE DEVICES 65
8.13.1. Disabling ACPI Soft-Off with the BIOS 65
8.13.2. Disabling ACPI Soft-Off in the logind.conf file 67
8.13.3. Disabling ACPI completely in the GRUB 2 File 67

. . . . . . . . . . . 9.
CHAPTER . . .CONFIGURING
. . . . . . . . . . . . . . . CLUSTER
. . . . . . . . . . .RESOURCES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
..............
Resource creation examples 68
Deleting a configured resource 68
9.1. RESOURCE AGENT IDENTIFIERS 68
9.2. DISPLAYING RESOURCE-SPECIFIC PARAMETERS 69
9.3. CONFIGURING RESOURCE META OPTIONS 70
9.3.1. Changing the default value of a resource option 72
9.3.2. Displaying currently configured resource defaults 72
9.3.3. Setting meta options on resource creation 72
9.4. CONFIGURING RESOURCE GROUPS 73
9.4.1. Creating a resource group 73
9.4.2. Removing a resource group 74
9.4.3. Displaying resource groups 74
9.4.4. Group options 74
9.4.5. Group stickiness 74
9.5. DETERMINING RESOURCE BEHAVIOR 74

.CHAPTER
. . . . . . . . . . 10.
. . . DETERMINING
. . . . . . . . . . . . . . . .WHICH
. . . . . . . .NODES
. . . . . . . .A. .RESOURCE
. . . . . . . . . . . . CAN
. . . . . RUN
. . . . . ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
..............
10.1. CONFIGURING LOCATION CONSTRAINTS 76
10.2. LIMITING RESOURCE DISCOVERY TO A SUBSET OF NODES 77
10.3. CONFIGURING A LOCATION CONSTRAINT STRATEGY 78
10.3.1. Configuring an "Opt-In" Cluster 79
10.3.2. Configuring an "Opt-Out" Cluster 79

.CHAPTER
. . . . . . . . . . 11.
. . .DETERMINING
. . . . . . . . . . . . . . . THE
. . . . .ORDER
. . . . . . . . IN
. . .WHICH
. . . . . . . .CLUSTER
. . . . . . . . . .RESOURCES
. . . . . . . . . . . . . .ARE
. . . . RUN
. . . . . . . . . . . . . . . . . . . . . . . . . . .80
..............
11.1. CONFIGURING MANDATORY ORDERING 81
11.2. CONFIGURING ADVISORY ORDERING 81
11.3. CONFIGURING ORDERED RESOURCE SETS 81

. . . . . . . . . . . 12.
CHAPTER . . . COLOCATING
. . . . . . . . . . . . . . . CLUSTER
. . . . . . . . . . .RESOURCES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84
..............
12.1. SPECIFYING MANDATORY PLACEMENT OF RESOURCES 84
12.2. SPECIFYING ADVISORY PLACEMENT OF RESOURCES 85
12.3. COLOCATING SETS OF RESOURCES 85

2
Table of Contents

12.4. REMOVING COLOCATION CONSTRAINTS 86

. . . . . . . . . . . 13.
CHAPTER . . . DISPLAYING
. . . . . . . . . . . . . .RESOURCE
. . . . . . . . . . . . CONSTRAINTS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87
..............
13.1. DISPLAYING ALL CONFIGURED CONSTRAINTS 87
13.2. DISPLAYING LOCATION CONSTRAINTS 87
13.3. DISPLAYING ORDERING CONSTRAINTS 87
13.4. DISPLAYING COLOCATION CONSTRAINTS 87
13.5. DISPLAYING RESOURCE-SPECIFIC CONSTRAINTS 87

.CHAPTER
. . . . . . . . . . 14.
. . . DETERMINING
. . . . . . . . . . . . . . . .RESOURCE
. . . . . . . . . . . . LOCATION
. . . . . . . . . . . .WITH
. . . . . . RULES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
..............
14.1. PACEMAKER RULES 88
14.1.1. Node attribute expressions 88
14.1.2. Time/date based expressions 90
14.1.3. Date specifications 91
14.2. CONFIGURING A PACEMAKER LOCATION CONSTRAINT USING RULES 91

.CHAPTER
. . . . . . . . . . 15.
. . . MANAGING
. . . . . . . . . . . . .CLUSTER
. . . . . . . . . . RESOURCES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93
..............
15.1. DISPLAYING CONFIGURED RESOURCES 93
15.2. MODIFYING RESOURCE PARAMETERS 93
15.3. CLEARING FAILURE STATUS OF CLUSTER RESOURCES 94
15.4. MOVING RESOURCES IN A CLUSTER 94
15.4.1. Moving resources due to failure 94
15.4.2. Moving resources due to connectivity changes 95
15.5. DISABLING A MONITOR OPERATION 96

CHAPTER 16. CREATING CLUSTER RESOURCES THAT ARE ACTIVE ON MULTIPLE NODES (CLONED
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98
RESOURCES) ..............
16.1. CREATING AND REMOVING A CLONED RESOURCE 98
16.2. CONFIGURING CLONE RESOURCE CONSTRAINTS 100
16.3. CREATING PROMOTABLE CLONE RESOURCES 101
16.3.1. Creating a promotable resource 101
16.3.2. Configuring promotable resource constraints 101

. . . . . . . . . . . 17.
CHAPTER . . . MANAGING
. . . . . . . . . . . . .CLUSTER
. . . . . . . . . . NODES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103
...............
17.1. STOPPING CLUSTER SERVICES 103
17.2. ENABLING AND DISABLING CLUSTER SERVICES 103
17.3. ADDING CLUSTER NODES 103
17.4. REMOVING CLUSTER NODES 105

. . . . . . . . . . . 18.
CHAPTER . . . SETTING
. . . . . . . . . . USER
. . . . . . PERMISSIONS
. . . . . . . . . . . . . . . .FOR
. . . . .A. PACEMAKER
. . . . . . . . . . . . . . CLUSTER
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106
...............
18.1. SETTING PERMISSIONS FOR NODE ACCESS OVER A NETWORK 106
18.2. SETTING LOCAL PERMISSIONS USING ACLS 106

. . . . . . . . . . . 19.
CHAPTER . . . RESOURCE
. . . . . . . . . . . . .MONITORING
. . . . . . . . . . . . . . OPERATIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
...............
19.1. CONFIGURING RESOURCE MONITORING OPERATIONS 109
19.2. CONFIGURING GLOBAL RESOURCE OPERATION DEFAULTS 110
19.3. CONFIGURING MULTIPLE MONITORING OPERATIONS 111

. . . . . . . . . . . 20.
CHAPTER . . . .PACEMAKER
. . . . . . . . . . . . . .CLUSTER
. . . . . . . . . . PROPERTIES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112
..............
20.1. SUMMARY OF CLUSTER PROPERTIES AND OPTIONS 112
20.2. SETTING AND REMOVING CLUSTER PROPERTIES 115
20.3. QUERYING CLUSTER PROPERTY SETTINGS 115

. . . . . . . . . . . 21.
CHAPTER . . . CONFIGURING
. . . . . . . . . . . . . . . .A. .NODE
. . . . . . .PLACEMENT
. . . . . . . . . . . . . .STRATEGY
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .117
..............
21.1. UTILIZATION ATTRIBUTES AND PLACEMENT STRATEGY 117
21.1.1. Configuring node and resource capacity 117

3
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

21.1.2. Configuring placement strategy 118


21.2. PACEMAKER RESOURCE ALLOCATION 118
21.2.1. Node Preference 118
21.2.2. Node Capacity 119
21.2.3. Resource Allocation Preference 119
21.3. RESOURCE PLACEMENT STRATEGY GUIDELINES 119
21.4. THE NODEUTILIZATION RESOURCE AGENT 120

. . . . . . . . . . . 22.
CHAPTER . . . .CONFIGURING
. . . . . . . . . . . . . . . .A. .VIRTUAL
. . . . . . . . . DOMAIN
. . . . . . . . . .AS
. . .A. .RESOURCE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121
..............
22.1. VIRTUAL DOMAIN RESOURCE OPTIONS 121
22.2. CREATING THE VIRTUAL DOMAIN RESOURCE 123

. . . . . . . . . . . 23.
CHAPTER . . . .CLUSTER
. . . . . . . . . . QUORUM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124
...............
23.1. CONFIGURING QUORUM OPTIONS 124
23.2. MODIFYING QUORUM OPTIONS 125
23.3. DISPLAYING QUORUM CONFIGURATION AND STATUS 125
23.4. RUNNING INQUORATE CLUSTERS 126
23.5. QUORUM DEVICES 126
23.5.1. Installing quorum device packages 127
23.5.2. Configuring a quorum device 127
23.5.3. Managing the Quorum Device Service 131
23.5.4. Managing the quorum device settings in a cluster 131
23.5.4.1. Changing quorum device settings 131
23.5.4.2. Removing a quorum device 132
23.5.4.3. Destroying a quorum device 132

. . . . . . . . . . . 24.
CHAPTER . . . .TRIGGERING
. . . . . . . . . . . . . .SCRIPTS
. . . . . . . . . FOR
. . . . . CLUSTER
. . . . . . . . . . .EVENTS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134
...............
24.1. INSTALLING AND CONFIGURING SAMPLE ALERT AGENTS 134
24.2. CREATING A CLUSTER ALERT 135
24.3. DISPLAYING, MODIFYING, AND REMOVING CLUSTER ALERTS 135
24.4. CONFIGURING ALERT RECIPIENTS 136
24.5. ALERT META OPTIONS 136
24.6. ALERT CONFIGURATION COMMAND EXAMPLES 137
24.7. WRITING AN ALERT AGENT 139

. . . . . . . . . . . 25.
CHAPTER . . . .CONFIGURING
. . . . . . . . . . . . . . . .MULTI-SITE
. . . . . . . . . . . . CLUSTERS
. . . . . . . . . . . . WITH
. . . . . . PACEMAKER
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142
...............
25.1. OVERVIEW OF BOOTH CLUSTER TICKET MANAGER 142
25.2. CONFIGURING MULTI-SITE CLUSTERS WITH PACEMAKER 142

CHAPTER 26. INTEGRATING NON-COROSYNC NODES INTO A CLUSTER: THE PACEMAKER_REMOTE


. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146
SERVICE ...............
26.1. HOST AND GUEST AUTHENTICATION OF PACEMAKER_REMOTE NODES 147
26.2. CONFIGURING KVM GUEST NODES 147
26.2.1. Guest node resource options 147
26.2.2. Integrating a virtual machine as a guest node 148
26.3. CONFIGURING PACEMAKER REMOTE NODES 149
26.3.1. Remote node resource options 149
26.3.2. Remote node configuration overview 149
26.4. CHANGING THE DEFAULT PORT LOCATION 150
26.5. UPGRADING SYSTEMS WITH PACEMAKER_REMOTE NODES 151

. . . . . . . . . . . 27.
CHAPTER . . . .PERFORMING
. . . . . . . . . . . . . . .CLUSTER
. . . . . . . . . . MAINTENANCE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
...............
27.1. PUTTING A NODE INTO STANDBY MODE 152
27.2. MANUALLY MOVING CLUSTER RESOURCES 153
27.2.1. Moving a resource from its current node 153

4
Table of Contents

27.2.2. Moving a resource to its preferred node 154


27.3. ENABLING, DISABLING, AND BANNING CLUSTER RESOURCES 154
27.4. SETTING A RESOURCE TO UNMANAGED MODE 155
27.5. PUTTING A CLUSTER IN MAINTENANCE MODE 156
27.6. UPDATING A RHEL HIGH AVAILABILITY CLUSTER 156
27.7. UPGRADING REMOTE NODES AND GUEST NODES 157

5
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

6
PROVIDING FEEDBACK ON RED HAT DOCUMENTATION

PROVIDING FEEDBACK ON RED HAT DOCUMENTATION


We appreciate your input on our documentation. Please let us know how we could make it better. To do
so:

For simple comments on specific passages, make sure you are viewing the documentation in the
Multi-page HTML format. Highlight the part of text that you want to comment on. Then, click
the Add Feedback pop-up that appears below the highlighted text, and follow the displayed
instructions.

For submitting more complex feedback, create a Bugzilla ticket:

1. Go to the Bugzilla website.

2. As the Component, use Documentation.

3. Fill in the Description field with your suggestion for improvement. Include a link to the
relevant part(s) of documentation.

4. Click Submit Bug.

7
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 1. HIGH AVAILABILITY ADD-ON OVERVIEW


The High Availability Add-On is a clustered system that provides reliability, scalability, and availability to
critical production services.

A cluster is two or more computers (called nodes or members) that work together to perform a task.
Clusters can be used to provide highly available services or resources. The redundancy of multiple
machines is used to guard against failures of many types.

High availability clusters provide highly available services by eliminating single points of failure and by
failing over services from one cluster node to another in case a node becomes inoperative. Typically,
services in a high availability cluster read and write data (by means of read-write mounted file systems).
Therefore, a high availability cluster must maintain data integrity as one cluster node takes over control
of a service from another cluster node. Node failures in a high availability cluster are not visible from
clients outside the cluster. (High availability clusters are sometimes referred to as failover clusters.) The
High Availability Add-On provides high availability clustering through its high availability service
management component, Pacemaker.

1.1. HIGH AVAILABILITY ADD-ON COMPONENTS


The High Availability Add-On consists of the following major components:

Cluster infrastructure — Provides fundamental functions for nodes to work together as a cluster:
configuration file management, membership management, lock management, and fencing.

High availability service management — Provides failover of services from one cluster node to
another in case a node becomes inoperative.

Cluster administration tools — Configuration and management tools for setting up, configuring,
and managing the High Availability Add-On. The tools are for use with the cluster infrastructure
components, the high availability and service management components, and storage.

You can supplement the High Availability Add-On with the following components:

Red Hat GFS2 (Global File System 2) — Part of the Resilient Storage Add-On, this provides a
cluster file system for use with the High Availability Add-On. GFS2 allows multiple nodes to
share storage at a block level as if the storage were connected locally to each cluster node.
GFS2 cluster file system requires a cluster infrastructure.

LVM Locking Daemon (lvmlockd) — Part of the Resilient Storage Add-On, this provides volume
management of cluster storage. lvmlockd support also requires cluster infrastructure.

Load Balancer Add-On — Routing software that provides high availability load balancing and
failover in layer 4 (TCP) and layer 7 (HTTP, HTTPS) services. The Load Balancer Add-On runs
in a cluster of redundant virtual routers that uses load algorithms to distribute client requests to
real servers, collectively acting as a virtual server. It is not necessary to use the Load Balancer
Add-On in conjunction with Pacemaker.

1.2. PACEMAKER OVERVIEW


Pacemaker is a cluster resource manager. It achieves maximum availability for your cluster services and
resources by making use of the cluster infrastructure’s messaging and membership capabilities to deter
and recover from node and resource-level failure.

1.2.1. Pacemaker architecture components

8
CHAPTER 1. HIGH AVAILABILITY ADD-ON OVERVIEW

A cluster configured with Pacemaker comprises separate component daemons that monitor cluster
membership, scripts that manage the services, and resource management subsystems that monitor the
disparate resources.

The following components form the Pacemaker architecture:

Cluster Information Base (CIB)


The Pacemaker information daemon, which uses XML internally to distribute and synchronize current
configuration and status information from the Designated Coordinator (DC) — a node assigned by
Pacemaker to store and distribute cluster state and actions by means of the CIB — to all other cluster
nodes.
Cluster Resource Management Daemon (CRMd)
Pacemaker cluster resource actions are routed through this daemon. Resources managed by CRMd
can be queried by client systems, moved, instantiated, and changed when needed.
Each cluster node also includes a local resource manager daemon (LRMd) that acts as an interface
between CRMd and resources. LRMd passes commands from CRMd to agents, such as starting and
stopping and relaying status information.

Shoot the Other Node in the Head (STONITH)


STONITH is the Pacemaker fencing implementation. It acts as a cluster resource in Pacemaker that
processes fence requests, forcefully powering down nodes and removing them from the cluster to
ensure data integrity. STONITH is configured in the CIB and can be monitored as a normal cluster
resource. For a general overview of fencing, see Section 1.3, “Fencing overview” .
corosync
corosync is the component - and a daemon of the same name - that serves the core membership
and member-communication needs for high availability clusters. It is required for the High Availability
Add-On to function.
In addition to those membership and messaging functions, corosync also:

Manages quorum rules and determination.

Provides messaging capabilities for applications that coordinate or operate across multiple
members of the cluster and thus must communicate stateful or other information between
instances.

Uses the kronosnet library as its network transport to provide multiple redundant links and
automatic failover.

1.2.2. Configuration and management tools


The High Availability Add-On features two configuration tools for cluster deployment, monitoring, and
management.

pcs
The pcs command line interface controls and configures Pacemaker and the corosync heartbeat
daemon. A command-line based program, pcs can perform the following cluster management tasks:

Create and configure a Pacemaker/Corosync cluster

Modify configuration of the cluster while it is running

Remotely configure both Pacemaker and Corosync as well as start, stop, and display status
information of the cluster

9
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

pcsd Web UI
A graphical user interface to create and configure Pacemaker/Corosync clusters.

1.2.3. The cluster and pacemaker configuration files


The configuration files for the Red Hat High Availability Add-On are corosync.conf and cib.xml.

The corosync.conf file provides the cluster parameters used by corosync, the cluster manager that
Pacemaker is built on. In general, you should not edit the corosync.conf directly but, instead, use the
pcs or pcsd interface.

The cib.xml file is an XML file that represents both the cluster’s configuration and the current state of
all resources in the cluster. This file is used by Pacemaker’s Cluster Information Base (CIB). The
contents of the CIB are automatically kept in sync across the entire cluster. Do not edit the cib.xml file
directly; use the pcs or pcsd interface instead.

1.3. FENCING OVERVIEW


If communication with a single node in the cluster fails, then other nodes in the cluster must be able to
restrict or release access to resources that the failed cluster node may have access to. This cannot be
accomplished by contacting the cluster node itself as the cluster node may not be responsive. Instead,
you must provide an external method, which is called fencing with a fence agent. A fence device is an
external device that can be used by the cluster to restrict access to shared resources by an errant node,
or to issue a hard reboot on the cluster node.

Without a fence device configured you do not have a way to know that the resources previously used by
the disconnected cluster node have been released, and this could prevent the services from running on
any of the other cluster nodes. Conversely, the system may assume erroneously that the cluster node
has released its resources and this can lead to data corruption and data loss. Without a fence device
configured data integrity cannot be guaranteed and the cluster configuration will be unsupported.

When the fencing is in progress no other cluster operation is allowed to run. Normal operation of the
cluster cannot resume until fencing has completed or the cluster node rejoins the cluster after the
cluster node has been rebooted.

For more information about fencing, see Fencing in a Red Hat High Availability Cluster.

1.4. QUORUM OVERVIEW


In order to maintain cluster integrity and availability, cluster systems use a concept known as quorum to
prevent data corruption and loss. A cluster has quorum when more than half of the cluster nodes are
online. To mitigate the chance of data corruption due to failure, Pacemaker by default stops all
resources if the cluster does not have quorum.

Quorum is established using a voting system. When a cluster node does not function as it should or loses
communication with the rest of the cluster, the majority working nodes can vote to isolate and, if
needed, fence the node for servicing.

For example, in a 6-node cluster, quorum is established when at least 4 cluster nodes are functioning. If
the majority of nodes go offline or become unavailable, the cluster no longer has quorum and
Pacemaker stops clustered services.

The quorum features in Pacemaker prevent what is also known as split-brain, a phenomenon where the
cluster is separated from communication but each part continues working as separate clusters,
potentially writing to the same data and possibly causing corruption or loss. For more information on

10
CHAPTER 1. HIGH AVAILABILITY ADD-ON OVERVIEW

what it means to be in a split-brain state, and on quorum concepts in general, see Exploring Concepts of
RHEL High Availability Clusters - Quorum.

A Red Hat Enterprise Linux High Availability Add-On cluster uses the votequorum service, in
conjunction with fencing, to avoid split brain situations. A number of votes is assigned to each system in
the cluster, and cluster operations are allowed to proceed only when a majority of votes is present.

1.5. RESOURCE OVERVIEW


A cluster resource is an instance of program, data, or application to be managed by the cluster service.
These resources are abstracted by agents that provide a standard interface for managing the resource
in a cluster environment.

To ensure that resources remain healthy, you can add a monitoring operation to a resource’s definition.
If you do not specify a monitoring operation for a resource, one is added by default.

You can determine the behavior of a resource in a cluster by configuring constraints. You can configure
the following categories of constraints:

location constraints — A location constraint determines which nodes a resource can run on.

ordering constraints — An ordering constraint determines the order in which the resources run.

colocation constraints — A colocation constraint determines where resources will be placed


relative to other resources.

One of the most common elements of a cluster is a set of resources that need to be located together,
start sequentially, and stop in the reverse order. To simplify this configuration, Pacemaker supports the
concept of groups.

1.6. LVM LOGICAL VOLUMES IN A RED HAT HIGH AVAILABILITY


CLUSTER
The Red Hat High Availability Add-On provides support for LVM volumes in two distinct cluster
configurations:

High availability LVM volumes (HA-LVM) in active/passive failover configurations in which only a
single node of the cluster accesses the storage at any one time.

LVM volumes that use the lvmlockd daemon to manage storage devices in active/active
configurations in which more than one node of the cluster requires access to the storage at the
same time. The lvmlockd daemon is part of the Resilient Storage Add-On.

1.6.1. Choosing HA-LVM or shared volumes


When to use HA-LVM or shared logical volumes managed by the lvmlockd daemon should be based on
the needs of the applications or services being deployed.

If multiple nodes of the cluster require simultaneous read/write access to LVM volumes in an
active/active system, then you must use the lvmlockd daemon and configure your volumes as
shared volumes. The lvmlockd daemon provides a system for coordinating activation of and
changes to LVM volumes across nodes of a cluster concurrently. The lvmlockd daemon’s
locking service provides protection to LVM metadata as various nodes of the cluster interact

11
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

with volumes and make changes to their layout. This protection is contingent upon configuring
any volume group that will be activated simultaneously across multiple cluster nodes as a shared
volume.

If the high availability cluster is configured to manage shared resources in an active/passive


manner with only one single member needing access to a given LVM volume at a time, then you
can use HA-LVM without the lvmlockd locking service.

Most applications will run better in an active/passive configuration, as they are not designed or
optimized to run concurrently with other instances. Choosing to run an application that is not cluster-
aware on shared logical volumes may result in degraded performance. This is because there is cluster
communication overhead for the logical volumes themselves in these instances. A cluster-aware
application must be able to achieve performance gains above the performance losses introduced by
cluster file systems and cluster-aware logical volumes. This is achievable for some applications and
workloads more easily than others. Determining what the requirements of the cluster are and whether
the extra effort toward optimizing for an active/active cluster will pay dividends is the way to choose
between the two LVM variants. Most users will achieve the best HA results from using HA-LVM.

HA-LVM and shared logical volumes using lvmlockd are similar in the fact that they prevent corruption
of LVM metadata and its logical volumes, which could otherwise occur if multiple machines are allowed
to make overlapping changes. HA-LVM imposes the restriction that a logical volume can only be
activated exclusively; that is, active on only one machine at a time. This means that only local (non-
clustered) implementations of the storage drivers are used. Avoiding the cluster coordination overhead
in this way increases performance. A shared volume using lvmlockd does not impose these restrictions
and a user is free to activate a logical volume on all machines in a cluster; this forces the use of cluster-
aware storage drivers, which allow for cluster-aware file systems and applications to be put on top.

1.6.2. Configuring LVM volumes in a cluster


In Red Hat Enterprise Linux 8, clusters are managed through Pacemaker. Both HA-LVM and shared
logical volumes are supported only in conjunction with Pacemaker clusters, and must be configured as
cluster resources.

For examples of procedures for configuring an HA-LVM volume as part of a Pacemaker cluster,
see Configuring an active/passive Apache HTTP server in a Red Hat High Availability cluster .
and Configuring an active/passive NFS server in a Red Hat High Availability cluster .
Note that these procedures include the following steps:

Ensuring that only the cluster is capable of activating the volume group

Configuring an LVM logical volume

Configuring the LVM volume as a cluster resource

For a procedure for configuring shared LVM volumes that use the lvmlockd daemon to manage
storage devices in active/active configurations, see Configuring a GFS2 file system in a cluster

12
CHAPTER 2. GETTING STARTED WITH PACEMAKER

CHAPTER 2. GETTING STARTED WITH PACEMAKER


The following procedures provide an introduction to the tools and processes you use to create a
Pacemaker cluster. They are intended for users who are interested in seeing what the cluster software
looks like and how it is administered, without needing to configure a working cluster.

NOTE

These procedures do not create a supported Red Hat cluster, which requires at least two
nodes and the configuration of a fencing device.

2.1. LEARNING TO USE PACEMAKER


This example requires a single node running RHEL 8 and it requires a floating IP address that resides on
the same network as one of the node’s statically assigned IP addresses.

The node used in this example is z1.example.com.

The floating IP address used in this example is 192.168.122.120.

NOTE

Ensure that the name of the node on which you are running is in your /etc/hosts file.

By working through this procedure, you will learn how to use Pacemaker to set up a cluster, how to
display cluster status, and how to configure a cluster service. This example creates an Apache HTTP
server as a cluster resource and shows how the cluster responds when the resource fails.

1. Install the Red Hat High Availability Add-On software packages from the High Availability
channel, and start and enable the pcsd service.

# yum install pcs pacemaker fence-agents-all


...
# systemctl start pcsd.service
# systemctl enable pcsd.service

If you are running the firewalld daemon, enable the ports that are required by the Red Hat High
Availability Add-On.

# firewall-cmd --permanent --add-service=high-availability


# firewall-cmd --reload

2. Set a password for user hacluster on each node in the cluster and authenticate user hacluster
for each node in the cluster on the node from which you will be running the pcs commands. This
example is using only a single node, the node from which you are running the commands, but
this step is included here since it is a necessary step in configuring a supported Red Hat High
Availability multi-node cluster.

# passwd hacluster
...
# pcs host auth z1.example.com

3. Create a cluster named my_cluster with one member and check the status of the cluster. This
13
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

3. Create a cluster named my_cluster with one member and check the status of the cluster. This
command creates and starts the cluster in one step.

# pcs cluster setup my_cluster --start z1.example.com


...
# pcs cluster status
Cluster Status:
Stack: corosync
Current DC: z1.example.com (version 2.0.0-10.el8-b67d8d0de9) - partition with quorum
Last updated: Thu Oct 11 16:11:18 2018
Last change: Thu Oct 11 16:11:00 2018 by hacluster via crmd on z1.example.com
1 node configured
0 resources configured

PCSD Status:
z1.example.com: Online

4. A Red Hat High Availability cluster requires that you configure fencing for the cluster. The
reasons for this requirement are described in Fencing in a Red Hat High Availability Cluster . For
this introduction, however, which is intended to show only how to use the basic Pacemaker
commands, disable fencing by setting the stonith-enabled cluster option to false.


WARNING

The use of stonith-enabled=false is completely inappropriate for a


production cluster. It tells the cluster to simply pretend that failed nodes
are safely fenced.

# pcs property set stonith-enabled=false

5. Configure a web browser on your system and create a web page to display a simple text
message. If you are running the firewalld daemon, enable the ports that are required by httpd.

NOTE

Do not use systemctl enable to enable any services that will be managed by the
cluster to start at system boot.

# yum install -y httpd wget


...
# firewall-cmd --permanent --add-service=http
# firewall-cmd --reload

# cat <<-END >/var/www/html/index.html


<html>
<body>My Test Site - $(hostname)</body>
</html>
END

14
CHAPTER 2. GETTING STARTED WITH PACEMAKER

In order for the Apache resource agent to get the status of Apache, create the following
addition to the existing configuration to enable the status server URL.

# cat <<-END > /etc/httpd/conf.d/status.conf


<Location /server-status>
SetHandler server-status
Order deny,allow
Deny from all
Allow from 127.0.0.1
Allow from ::1
</Location>
END

6. Create IPaddr2 and apache resources for the cluster to manage. The 'IPaddr2' resource is a
floating IP address that must not be one already associated with a physical node. If the 'IPaddr2'
resource’s NIC device is not specified, the floating IP must reside on the same network as the
statically assigned IP address used by the node.
You can display a list of all available resource types with the pcs resource list command. You
can use the pcs resource describe resourcetype command to display the parameters you can
set for the specified resource type. For example, the following command displays the
parameters you can set for a resource of type apache:

# pcs resource describe apache


...

In this example, the IP address resource and the apache resource are both configured as part of
a group named apachegroup, which ensures that the resources are kept together to run on the
same node when you are configuring a working multi-node cluster.

# pcs resource create ClusterIP ocf:heartbeat:IPaddr2 ip=192.168.122.120 --group


apachegroup

# pcs resource create WebSite ocf:heartbeat:apache


configfile=/etc/httpd/conf/httpd.conf statusurl="http://localhost/server-status" --group
apachegroup

# pcs status
Cluster name: my_cluster
Stack: corosync
Current DC: z1.example.com (version 2.0.0-10.el8-b67d8d0de9) - partition with quorum
Last updated: Fri Oct 12 09:54:33 2018
Last change: Fri Oct 12 09:54:30 2018 by root via cibadmin on z1.example.com

1 node configured
2 resources configured

Online: [ z1.example.com ]

Full list of resources:

Resource Group: apachegroup


ClusterIP (ocf::heartbeat:IPaddr2): Started z1.example.com
WebSite (ocf::heartbeat:apache): Started z1.example.com

15
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

PCSD Status:
z1.example.com: Online
...

After you have configured a cluster resource, you can use the pcs resource config command to
display the options that are configured for that resource.

# pcs resource config WebSite


Resource: WebSite (class=ocf provider=heartbeat type=apache)
Attributes: configfile=/etc/httpd/conf/httpd.conf statusurl=http://localhost/server-status
Operations: start interval=0s timeout=40s (WebSite-start-interval-0s)
stop interval=0s timeout=60s (WebSite-stop-interval-0s)
monitor interval=1min (WebSite-monitor-interval-1min)

7. Point your browser to the website you created using the floating IP address you configured. This
should display the text message you defined.

8. Stop the apache web service and check the cluster status. Using killall -9 simulates an
application-level crash.

# killall -9 httpd

Check the cluster status. You should see that stopping the web service caused a failed action,
but that the cluster software restarted the service and you should still be able to access the
website.

# pcs status
Cluster name: my_cluster
...
Current DC: z1.example.com (version 1.1.13-10.el7-44eb2dd) - partition with quorum
1 node and 2 resources configured

Online: [ z1.example.com ]

Full list of resources:

Resource Group: apachegroup


ClusterIP (ocf::heartbeat:IPaddr2): Started z1.example.com
WebSite (ocf::heartbeat:apache): Started z1.example.com

Failed Resource Actions:


* WebSite_monitor_60000 on z1.example.com 'not running' (7): call=13, status=complete,
exitreason='none',
last-rc-change='Thu Oct 11 23:45:50 2016', queued=0ms, exec=0ms

PCSD Status:
z1.example.com: Online

You can clear the failure status on the resource that failed once the service is up and running
again and the failed action notice will no longer appear when you view the cluster status.

# pcs resource cleanup WebSite

9. When you are finished looking at the cluster and the cluster status, stop the cluster services on

16
CHAPTER 2. GETTING STARTED WITH PACEMAKER

the node. Even though you have only started services on one node for this introduction, the --all
parameter is included since it would stop cluster services on all nodes on an actual multi-node
cluster.

# pcs cluster stop --all

2.2. LEARNING TO CONFIGURE FAILOVER


This procedure provides an introduction to creating a Pacemaker cluster running a service that will fail
over from one node to another when the node on which the service is running becomes unavailable. By
working through this procedure, you can learn how to create a service in a two-node cluster and you can
then observe what happens to that service when it fails on the node on which it running.

This example procedure configures a two-node Pacemaker cluster running an Apache HTTP server. You
can then stop the Apache service on one node to see how the service remains available.

This procedure requires as a prerequisite that you have two nodes running Red Hat Enterprise Linux 8
that can communicate with each other, and it requires a floating IP address that resides on the same
network as one of the node’s statically assigned IP addresses.

The nodes used in this example are z1.example.com and z2.example.com.

The floating IP address used in this example is 192.168.122.120.

NOTE

Ensure that the names of the nodes you are using are in the /etc/hosts file on each node.

1. On both nodes, install the Red Hat High Availability Add-On software packages from the High
Availability channel, and start and enable the pcsd service.

# yum install pcs pacemaker fence-agents-all


...
# systemctl start pcsd.service
# systemctl enable pcsd.service

If you are running the firewalld daemon, on both nodes enable the ports that are required by
the Red Hat High Availability Add-On.

# firewall-cmd --permanent --add-service=high-availability


# firewall-cmd --reload

2. On both nodes in the cluster, set a password for user hacluster .

# passwd hacluster

3. Authenticate user hacluster for each node in the cluster on the node from which you will be
running the pcs commands.

# pcs host auth z1.example.com z2.example.com

4. Create a cluster named my_cluster with both nodes as cluster members. This command

17
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

4. Create a cluster named my_cluster with both nodes as cluster members. This command
creates and starts the cluster in one step. You only need to run this from one node in the cluster
because pcs configuration commands take effect for the entire cluster.
On one node in cluster, run the following command.

# pcs cluster setup my_cluster --start z1.example.com z2.example.com

5. A Red Hat High Availability cluster requires that you configure fencing for the cluster. The
reasons for this requirement are described in Fencing in a Red Hat High Availability Cluster . For
this introduction, however, to show only how failover works in this configuration, disable fencing
by setting the stonith-enabled cluster option to false


WARNING

The use of stonith-enabled=false is completely inappropriate for a


production cluster. It tells the cluster to simply pretend that failed nodes
are safely fenced.

# pcs property set stonith-enabled=false

6. After creating a cluster and disabling fencing, check the status of the cluster.

NOTE

When you run the pcs cluster status command, it may show output that
temporarily differs slightly from the examples as the system components start up.

# pcs cluster status


Cluster Status:
Stack: corosync
Current DC: z1.example.com (version 2.0.0-10.el8-b67d8d0de9) - partition with quorum
Last updated: Thu Oct 11 16:11:18 2018
Last change: Thu Oct 11 16:11:00 2018 by hacluster via crmd on z1.example.com
2 nodes configured
0 resources configured

PCSD Status:
z1.example.com: Online
z2.example.com: Online

7. On both nodes, configure a web browser and create a web page to display a simple text
message. If you are running the firewalld daemon, enable the ports that are required by httpd.

NOTE

Do not use systemctl enable to enable any services that will be managed by the
cluster to start at system boot.

18
CHAPTER 2. GETTING STARTED WITH PACEMAKER

# yum install -y httpd wget


...
# firewall-cmd --permanent --add-service=http
# firewall-cmd --reload

# cat <<-END >/var/www/html/index.html


<html>
<body>My Test Site - $(hostname)</body>
</html>
END

In order for the Apache resource agent to get the status of Apache, on each node in the cluster
create the following addition to the existing configuration to enable the status server URL.

# cat <<-END > /etc/httpd/conf.d/status.conf


<Location /server-status>
SetHandler server-status
Order deny,allow
Deny from all
Allow from 127.0.0.1
Allow from ::1
</Location>
END

8. Create IPaddr2 and apache resources for the cluster to manage. The 'IPaddr2' resource is a
floating IP address that must not be one already associated with a physical node. If the 'IPaddr2'
resource’s NIC device is not specified, the floating IP must reside on the same network as the
statically assigned IP address used by the node.
You can display a list of all available resource types with the pcs resource list command. You
can use the pcs resource describe resourcetype command to display the parameters you can
set for the specified resource type. For example, the following command displays the
parameters you can set for a resource of type apache:

# pcs resource describe apache


...

In this example, the IP address resource and the apache resource are both configured as part of
a group named apachegroup, which ensures that the resources are kept together to run on the
same node.

Run the following commands from one node in the cluster:

# pcs resource create ClusterIP ocf:heartbeat:IPaddr2 ip=192.168.122.120 --group


apachegroup

# pcs resource create WebSite ocf:heartbeat:apache


configfile=/etc/httpd/conf/httpd.conf statusurl="http://localhost/server-status" --group
apachegroup

# pcs status
Cluster name: my_cluster
Stack: corosync
Current DC: z1.example.com (version 2.0.0-10.el8-b67d8d0de9) - partition with quorum
Last updated: Fri Oct 12 09:54:33 2018

19
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Last change: Fri Oct 12 09:54:30 2018 by root via cibadmin on z1.example.com

2 nodes configured
2 resources configured

Online: [ z1.example.com z2.example.com ]

Full list of resources:

Resource Group: apachegroup


ClusterIP (ocf::heartbeat:IPaddr2): Started z1.example.com
WebSite (ocf::heartbeat:apache): Started z1.example.com

PCSD Status:
z1.example.com: Online
z2.example.com: Online
...

Note that in this instance, the apachegroup service is running on node z1.example.com.

9. Access the website you created, stop the service on the node on which it is running, and note
how the service fails over to the second node.

a. Point a browser to the website you created using the floating IP address you configured.
This should display the text message you defined, displaying the name of the node on which
the website is running.

b. Stop the apache web service. Using killall -9 simulates an application-level crash.

# killall -9 httpd

Check the cluster status. You should see that stopping the web service caused a failed
action, but that the cluster software restarted the service on the node on which it had been
running and you should still be able to access the web browser.

# pcs status
Cluster name: my_cluster
Stack: corosync
Current DC: z1.example.com (version 2.0.0-10.el8-b67d8d0de9) - partition with quorum
Last updated: Fri Oct 12 09:54:33 2018
Last change: Fri Oct 12 09:54:30 2018 by root via cibadmin on z1.example.com

2 nodes configured
2 resources configured

Online: [ z1.example.com z2.example.com ]

Full list of resources:

Resource Group: apachegroup


ClusterIP (ocf::heartbeat:IPaddr2): Started z1.example.com
WebSite (ocf::heartbeat:apache): Started z1.example.com

Failed Resource Actions:

20
CHAPTER 2. GETTING STARTED WITH PACEMAKER

* WebSite_monitor_60000 on z1.example.com 'not running' (7): call=31,


status=complete, exitreason='none',
last-rc-change='Fri Feb 5 21:01:41 2016', queued=0ms, exec=0ms

Clear the failure status once the service is up and running again.

# pcs resource cleanup WebSite

c. Put the node on which the service is running into standby mode. Note that since we have
disabled fencing we can not effectively simulate a node-level failure (such as pulling a
power cable) because fencing is required for the cluster to recover from such situations.

# pcs node standby z1.example.com

d. Check the status of the cluster and note where the service is now running.

# pcs status
Cluster name: my_cluster
Stack: corosync
Current DC: z1.example.com (version 2.0.0-10.el8-b67d8d0de9) - partition with quorum
Last updated: Fri Oct 12 09:54:33 2018
Last change: Fri Oct 12 09:54:30 2018 by root via cibadmin on z1.example.com

2 nodes configured
2 resources configured

Node z1.example.com: standby


Online: [ z2.example.com ]

Full list of resources:

Resource Group: apachegroup


ClusterIP (ocf::heartbeat:IPaddr2): Started z2.example.com
WebSite (ocf::heartbeat:apache): Started z2.example.com

e. Access the website. There should be no loss of service, although the display message
should indicate the node on which the service is now running.

10. To restore cluster services to the first node, take the node out of standby mode. This will not
necessarily move the service back to that node.

# pcs cluster unstandby z1.example.com

11. For final cleanup, stop the cluster services on both nodes.

# pcs cluster stop --all

21
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 3. THE PCS COMMAND LINE INTERFACE


The pcs command line interface controls and configures cluster services such as corosync,
pacemaker,booth, and sbd by providing an easier interface to their configuration files.

Note that you should not edit the cib.xml configuration file directly. In most cases, Pacemaker will reject
a directly modified cib.xml file.

3.1. PCS HELP DISPLAY


You can use the -h option of pcs to display the parameters of a pcs command and a description of
those parameters. For example, the following command displays the parameters of the pcs resource
command. Only a portion of the output is shown.

# pcs resource -h

3.2. VIEWING THE RAW CLUSTER CONFIGURATION


Although you should not edit the cluster configuration file directly, you can view the raw cluster
configuration with the pcs cluster cib command.

You can save the raw cluster configuration to a specified file with the pcs cluster cib filename
command. If you have previously configured a cluster and there is already an active CIB, you use the
following command to save the raw xml file.

pcs cluster cib filename

For example, the following command saves the raw xml from the CIB into a file named testfile.

pcs cluster cib testfile

3.3. SAVING A CONFIGURATION CHANGE TO A WORKING FILE


When configuring a cluster, you can save configuration changes to a specified file without affecting the
active CIB. This allows you to specify configuration updates without immediately updating the currently
running cluster configuration with each individual update.

For information on saving the CIB to a file, see Viewing the raw cluster configuration. Once you have
created that file, you can save configuration changes to that file rather than to the active CIB by using
the -f option of the pcs command. When you have completed the changes and are ready to update the
active CIB file, you can push those file updates with the pcs cluster cib-push command.

The following is the recommended procedure for pushing changes to the CIB file. This procedure
creates a copy of the original saved CIB file and makes changes to that copy. When pushing those
changes to the active CIB, this procedure specifies the diff-against option of the pcs cluster cib-push
command so that only the changes between the original file and the updated file are pushed to the CIB.
This allows users to make changes in parallel that do not overwrite each other, and it reduces the load
on Pacemaker which does not need to parse the entire configuration file.

1. Save the active CIB to a file. This example saves the CIB to a file named original.xml.

# pcs cluster cib original.xml

22
CHAPTER 3. THE PCS COMMAND LINE INTERFACE

2. Copy the saved file to the working file you will be using for the configuration updates.

# cp original.xml updated.xml

3. Update your configuration as needed. The following command creates a resource in the file
updated.xml but does not add that resource to the currently running cluster configuration.

# pcs -f updated.xml resource create VirtualIP ocf:heartbeat:IPaddr2 ip=192.168.0.120


op monitor interval=30s

4. Push the updated file to the active CIB, specifying that you are pushing only the changes you
have made to the original file.

# pcs cluster cib-push updated.xml diff-against=original.xml

Alternately, you can push the entire current content of a CIB file with the following command.

pcs cluster cib-push filename

When pushing the entire CIB file, Pacemaker checks the version and does not allow you to push a CIB
file which is older than the one already in a cluster. If you need to update the entire CIB file with a version
that is older than the one currently in the cluster, you can use the --config option of the pcs cluster
cib-push command.

pcs cluster cib-push --config filename

3.4. DISPLAYING CLUSTER STATUS


You can display the status of the cluster and the cluster resources with the following command.

pcs status

You can display the status of a particular cluster component with the commands parameter of the pcs
status command, specifying resources, cluster, nodes, or pcsd.

pcs status commands

For example, the following command displays the status of the cluster resources.

pcs status resources

The following command displays the status of the cluster, but not the cluster resources.

pcs cluster status

3.5. DISPLAYING THE FULL CLUSTER CONFIGURATION


Use the following command to display the full current cluster configuration.

pcs config

23
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 4. CREATING A RED HAT HIGH-AVAILABILITY


CLUSTER WITH PACEMAKER
The following procedure creates a Red Hat High Availability two-node cluster using pcs.

Configuring the cluster in this example requires that your system include the following components:

2 nodes, which will be used to create the cluster. In this example, the nodes used are
z1.example.com and z2.example.com.

Network switches for the private network. We recommend but do not require a private network
for communication among the cluster nodes and other cluster hardware such as network power
switches and Fibre Channel switches.

A fencing device for each node of the cluster. This example uses two ports of the APC power
switch with a host name of zapc.example.com.

4.1. INSTALLING CLUSTER SOFTWARE


The procedure for installing cluster software and configuring your system for cluster creation is as
follows.

1. On each node in the cluster, install the Red Hat High Availability Add-On software packages
along with all available fence agents from the High Availability channel.

# yum install pcs pacemaker fence-agents-all

Alternatively, you can install the Red Hat High Availability Add-On software packages along with
only the fence agent that you require with the following command.

# yum install pcs pacemaker fence-agents-model

The following command displays a listing of the available fence agents.

# rpm -q -a | grep fence


fence-agents-rhevm-4.0.2-3.el7.x86_64
fence-agents-ilo-mp-4.0.2-3.el7.x86_64
fence-agents-ipmilan-4.0.2-3.el7.x86_64
...


WARNING

After you install the Red Hat High Availability Add-On packages, you should
ensure that your software update preferences are set so that nothing is
installed automatically. Installation on a running cluster can cause
unexpected behaviors. For more information, see Recommended Practices
for Applying Software Updates to a RHEL High Availability or Resilient
Storage Cluster.

24
CHAPTER 4. CREATING A RED HAT HIGH-AVAILABILITY CLUSTER WITH PACEMAKER

2. If you are running the firewalld daemon, execute the following commands to enable the ports
that are required by the Red Hat High Availability Add-On.

NOTE

You can determine whether the firewalld daemon is installed on your system
with the rpm -q firewalld command. If it is installed, you can determine whether
it is running with the firewall-cmd --state command.

# firewall-cmd --permanent --add-service=high-availability


# firewall-cmd --add-service=high-availability

NOTE

The ideal firewall configuration for cluster components depends on the local
environment, where you may need to take into account such considerations as
whether the nodes have multiple network interfaces or whether off-host
firewalling is present. The example here, which opens the ports that are generally
required by a Pacemaker cluster, should be modified to suit local conditions.
Enabling ports for the High Availability Add-On shows the ports to enable for the
Red Hat High Availability Add-On and provides an explanation for what each port
is used for.

3. In order to use pcs to configure the cluster and communicate among the nodes, you must set a
password on each node for the user ID hacluster, which is the pcs administration account. It is
recommended that the password for user hacluster be the same on each node.

# passwd hacluster
Changing password for user hacluster.
New password:
Retype new password:
passwd: all authentication tokens updated successfully.

4. Before the cluster can be configured, the pcsd daemon must be started and enabled to start up
on boot on each node. This daemon works with the pcs command to manage configuration
across the nodes in the cluster.
On each node in the cluster, execute the following commands to start the pcsd service and to
enable pcsd at system start.

# systemctl start pcsd.service


# systemctl enable pcsd.service

5. Authenticate the pcs user hacluster for each node in the cluster on the node from which you
will be running pcs.
The following command authenticates user hacluster on z1.example.com for both of the
nodes in the example two-node cluster, z1.example.com and z2.example.com.

[root@z1 ~]# pcs host auth z1.example.com z2.example.com


Username: hacluster
Password:
z1.example.com: Authorized
z2.example.com: Authorized

25
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

4.2. CREATING A HIGH AVAILABILITY CLUSTER


This procedure creates a Red Hat High Availability Add-On cluster that consists of the nodes
z1.example.com and z2.example.com.

1. Execute the following command from z1.example.com to create the two-node cluster
my_cluster that consists of nodes z1.example.com and z2.example.com. This will propagate
the cluster configuration files to both nodes in the cluster. This command includes the --start
option, which will start the cluster services on both nodes in the cluster.

[root@z1 ~]# pcs cluster setup my_cluster --start z1.example.com z2.example.com

2. Enable the cluster services to run on each node in the cluster when the node is booted.

NOTE

For your particular environment, you may choose to leave the cluster services
disabled by skipping this step. This allows you to ensure that if a node goes down,
any issues with your cluster or your resources are resolved before the node
rejoins the cluster. If you leave the cluster services disabled, you will need to
manually start the services when you reboot a node by executing the pcs cluster
start command on that node.

[root@z1 ~]# pcs cluster enable --all

You can display the current status of the cluster with the pcs cluster status command. Because there
may be a slight delay before the cluster is up and running when you start the cluster services with the --
start option of the pcs cluster setup command, you should ensure that the cluster is up and running
before performing any subsequent actions on the cluster and its configuration.

[root@z1 ~]# pcs cluster status


Cluster Status:
Stack: corosync
Current DC: z2.example.com (version 2.0.0-10.el8-b67d8d0de9) - partition with quorum
Last updated: Thu Oct 11 16:11:18 2018
Last change: Thu Oct 11 16:11:00 2018 by hacluster via crmd on z2.example.com
2 Nodes configured
0 Resources configured

...

4.3. CREATING A HIGH AVAILABILITY CLUSTER WITH MULTIPLE


LINKS
You can use the pcs cluster setup command to create a Red Hat High Availability cluster with multiple
links by specifying all of the links for each node.

The format for the command to create a two-node cluster with two links is as follows.

pcs cluster setup cluster_name node1_name addr=node1_link0_address addr=node1_link1_address


node2_name addr=node2_link0_address addr=node2_link1_address

26
CHAPTER 4. CREATING A RED HAT HIGH-AVAILABILITY CLUSTER WITH PACEMAKER

When creating a cluster with multiple links, you should take the following into account.

The order of the addr=address parameters is important. The first address specified after a
node name is for link0, the second one for link1, and so forth.

It is possible to specify up to eight links using the knet transport protocol, which is the default
transport protocol.

All nodes must have the same number of addr= parameters.

Currently, it is not possible to add, remove, or change links in an existing cluster using the pcs
command.

As with single-link clusters, do not mix IPv4 and IPv6 addresses in one link, although you can
have one link running IPv4 and the other running IPv6.

As with single-link clusters, you can specify addresses as IP addresses or as names as long as the
names resolve to IPv4 or IPv6 addresses for which IPv4 and IPv6 addresses are not mixed in one
link.

The following example creates a two-node cluster named my_twolink_cluster with two nodes, rh80-
node1 and rh80-node2. rh80-node1 has two interfaces, IP address 192.168.122.201 as link0 and
192.168.123.201 as link1. rh80-node2 has two interfaces, IP address 192.168.122.202 as link0 and
192.168.123.202 as link1.

# pcs cluster setup my_twolink_cluster rh80-node1 addr=192.168.122.201


addr=192.168.123.201 rh80-node2 addr=192.168.122.202 addr=192.168.123.202

When adding a node to a cluster with multiple links, you must specify addresses for all links. The
following example adds the node rh80-node3 to a cluster, specifying IP address 192.168.122.203 as link0
and 192.168.123.203 as link1.

# pcs cluster node add rh80-node3 addr=192.168.122.203 addr=192.168.123.203

4.4. CONFIGURING FENCING


You must configure a fencing device for each node in the cluster. For information about the fence
configuration commands and options, see Configuring fencing in a Red Hat High Availability cluster .

For general information on fencing and its importance in a Red Hat High Availability cluster, see Fencing
in a Red Hat High Availability Cluster.

NOTE

When configuring a fencing device, attention should be given to whether that device
shares power with any nodes or devices in the cluster. If a node and its fence device do
share power, then the cluster may be at risk of being unable to fence that node if the
power to it and its fence device should be lost. Such a cluster should either have
redundant power supplies for fence devices and nodes, or redundant fence devices that
do not share power. Alternative methods of fencing such as SBD or storage fencing may
also bring redundancy in the event of isolated power losses.

This example uses the APC power switch with a host name of zapc.example.com to fence the nodes,
and it uses the fence_apc_snmp fencing agent. Because both nodes will be fenced by the same

27
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

fencing agent, you can configure both fencing devices as a single resource, using the pcmk_host_map
option.

You create a fencing device by configuring the device as a stonith resource with the pcs stonith create
command. The following command configures a stonith resource named myapc that uses the
fence_apc_snmp fencing agent for nodes z1.example.com and z2.example.com. The
pcmk_host_map option maps z1.example.com to port 1, and z2.example.com to port 2. The login
value and password for the APC device are both apc. By default, this device will use a monitor interval of
sixty seconds for each node.

Note that you can use an IP address when specifying the host name for the nodes.

[root@z1 ~]# pcs stonith create myapc fence_apc_snmp \


ipaddr="zapc.example.com" pcmk_host_map="z1.example.com:1;z2.example.com:2" \
login="apc" passwd="apc"

The following command displays the parameters of an existing STONITH device.

[root@rh7-1 ~]# pcs stonith config myapc


Resource: myapc (class=stonith type=fence_apc_snmp)
Attributes: ipaddr=zapc.example.com pcmk_host_map=z1.example.com:1;z2.example.com:2
login=apc passwd=apc
Operations: monitor interval=60s (myapc-monitor-interval-60s)

After configuring your fence device, you should test the device. For information on testing a fence
device, see Testing a fence device .

NOTE

Do not test your fence device by disabling the network interface, as this will not properly
test fencing.

NOTE

Once fencing is configured and a cluster has been started, a network restart will trigger
fencing for the node which restarts the network even when the timeout is not exceeded.
For this reason, do not restart the network service while the cluster service is running
because it will trigger unintentional fencing on the node.

4.5. BACKING UP AND RESTORING A CLUSTER CONFIGURATION


You can back up the cluster configuration in a tarball with the following command. If you do not specify a
file name, the standard output will be used.

pcs config backup filename

NOTE
28
CHAPTER 4. CREATING A RED HAT HIGH-AVAILABILITY CLUSTER WITH PACEMAKER

NOTE

The pcs config backup command backs up only the cluster configuration itself as
configured in the CIB; the configuration of resource daemons is out of the scope of this
command. For example if you have configured an Apache resource in the cluster, the
resource settings (which are in the CIB) will be backed up, while the Apache daemon
settings (as set in`/etc/httpd`) and the files it serves will not be backed up. Similarly, if
there is a database resource configured in the cluster, the database itself will not be
backed up, while the database resource configuration (CIB) will be.

Use the following command to restore the cluster configuration files on all nodes from the backup. If you
do not specify a file name, the standard input will be used. Specifying the --local option restores only
the files on the current node.

pcs config restore [--local] [filename]

4.6. ENABLING PORTS FOR THE HIGH AVAILABILITY ADD-ON


The ideal firewall configuration for cluster components depends on the local environment, where you
may need to take into account such considerations as whether the nodes have multiple network
interfaces or whether off-host firewalling is present.

If you are running the firewalld daemon, execute the following commands to enable the ports that are
required by the Red Hat High Availability Add-On.

# firewall-cmd --permanent --add-service=high-availability


# firewall-cmd --add-service=high-availability

You may need to modify which ports are open to suit local conditions.

NOTE

You can determine whether the firewalld daemon is installed on your system with the
rpm -q firewalld command. If the firewalld daemon is installed, you can determine
whether it is running with the firewall-cmd --state command.

Table 4.1, “Ports to Enable for High Availability Add-On” shows the ports to enable for the Red Hat High
Availability Add-On and provides an explanation for what the port is used for.

Table 4.1. Ports to Enable for High Availability Add-On

Port When Required

29
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Port When Required

TCP 2224 Default pcsd port required on all nodes (needed by


the pcsd Web UI and required for node-to-node
communication). You can configure the pcsd port by
means of the PCSD_PORT parameter in the
/etc/sysconfig/pcsd file.

It is crucial to open port 2224 in such a way that pcs


from any node can talk to all nodes in the cluster,
including itself. When using the Booth cluster ticket
manager or a quorum device you must open port
2224 on all related hosts, such as Booth arbiters or
the quorum device host.

TCP 3121 Required on all nodes if the cluster has any


Pacemaker Remote nodes

Pacemaker’s pacemaker-based daemon on the


full cluster nodes will contact the
pacemaker_remoted daemon on Pacemaker
Remote nodes at port 3121. If a separate interface is
used for cluster communication, the port only needs
to be open on that interface. At a minimum, the port
should open on Pacemaker Remote nodes to full
cluster nodes. Because users may convert a host
between a full node and a remote node, or run a
remote node inside a container using the host’s
network, it can be useful to open the port to all
nodes. It is not necessary to open the port to any
hosts other than nodes.

TCP 5403 Required on the quorum device host when using a


quorum device with corosync-qnetd. The default
value can be changed with the -p option of the
corosync-qnetd command.

UDP 5404-5412 Required on corosync nodes to facilitate


communication between nodes. It is crucial to open
ports 5404-5412 in such a way that corosync from
any node can talk to all nodes in the cluster, including
itself.

TCP 21064 Required on all nodes if the cluster contains any


resources requiring DLM (such as GFS2 ).

TCP 9929, UDP 9929 Required to be open on all cluster nodes and booth
arbitrator nodes to connections from any of those
same nodes when the Booth ticket manager is used
to establish a multi-site cluster.

30
CHAPTER 5. CONFIGURING AN ACTIVE/PASSIVE APACHE HTTP SERVER IN A RED HAT HIGH AVAILABILITY CLUSTER

CHAPTER 5. CONFIGURING AN ACTIVE/PASSIVE APACHE


HTTP SERVER IN A RED HAT HIGH AVAILABILITY CLUSTER
The following procedure configures an active/passive Apache HTTP server in a two-node Red Hat
Enterprise Linux High Availability Add-On cluster using pcs to configure cluster resources. In this use
case, clients access the Apache HTTP server through a floating IP address. The web server runs on one
of two nodes in the cluster. If the node on which the web server is running becomes inoperative, the web
server starts up again on the second node of the cluster with minimal service interruption.

Figure 5.1, “Apache in a Red Hat High Availability Two-Node Cluster” shows a high-level overview of the
cluster in which The cluster is a two-node Red Hat High Availability cluster which is configured with a
network power switch and with shared storage. The cluster nodes are connected to a public network, for
client access to the Apache HTTP server through a virtual IP. The Apache server runs on either Node 1
or Node 2, each of which has access to the storage on which the Apache data is kept. In this illustration,
the web server is running on Node 1 while Node 2 is available to run the server if Node 1 becomes
inoperative.

Figure 5.1. Apache in a Red Hat High Availability Two-Node Cluster

This use case requires that your system include the following components:

A two-node Red Hat High Availability cluster with power fencing configured for each node. We
recommend but do not require a private network. This procedure uses the cluster example
provided in Creating a Red Hat High-Availability cluster with Pacemaker .

A public virtual IP address, required for Apache.

Shared storage for the nodes in the cluster, using iSCSI or Fibre Channel.

The cluster is configured with an Apache resource group, which contains the cluster components that
the web server requires: an LVM resource, a file system resource, an IP address resource, and a web
server resource. This resource group can fail over from one node of the cluster to the other, allowing
either node to run the web server. Before creating the resource group for this cluster, you will be
performing the following procedures:

31
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

1. Configure an ext4 file system on the logical volume my_lv.

2. Configure a web server.

After performing these steps, you create the resource group and the resources it contains.

5.1. CONFIGURING AN LVM VOLUME WITH AN EXT4 FILE SYSTEM IN A


PACEMAKER CLUSTER
This use case requires that you create an LVM logical volume on storage that is shared between the
nodes of the cluster.

NOTE

LVM volumes and the corresponding partitions and devices used by cluster nodes must
be connected to the cluster nodes only.

The following procedure creates an LVM logical volume and then creates an ext4 file system on that
volume for use in a Pacemaker cluster. In this example, the shared partition /dev/sdb1 is used to store
the LVM physical volume from which the LVM logical volume will be created.

1. On both nodes of the cluster, perform the following steps to set the value for the LVM system
ID to the value of the uname identifier for the system. The LVM system ID will be used to
ensure that only the cluster is capable of activating the volume group.

a. Set the system_id_source configuration option in the /etc/lvm/lvm.conf configuration file


to uname.

# Configuration option global/system_id_source.


system_id_source = "uname"

b. Verify that the LVM system ID on the node matches the uname for the node.

# lvm systemid
system ID: z1.example.com
# uname -n
z1.example.com

2. Create the LVM volume and create an ext4 file system on that volume. Since the /dev/sdb1
partition is storage that is shared, you perform this part of the procedure on one node only.

a. Create an LVM physical volume on partition /dev/sdb1.

# pvcreate /dev/sdb1
Physical volume "/dev/sdb1" successfully created

b. Create the volume group my_vg that consists of the physical volume /dev/sdb1.

# vgcreate my_vg /dev/sdb1


Volume group "my_vg" successfully created

c. Verify that the new volume group has the system ID of the node on which you are running
and from which you created the volume group.

32
CHAPTER 5. CONFIGURING AN ACTIVE/PASSIVE APACHE HTTP SERVER IN A RED HAT HIGH AVAILABILITY CLUSTER

# vgs -o+systemid
VG #PV #LV #SN Attr VSize VFree System ID
my_vg 1 0 0 wz--n- <1.82t <1.82t z1.example.com

d. Create a logical volume using the volume group my_vg.

# lvcreate -L450 -n my_lv my_vg


Rounding up size to full physical extent 452.00 MiB
Logical volume "my_lv" created

You can use the lvs command to display the logical volume.

# lvs
LV VG Attr LSize Pool Origin Data% Move Log Copy% Convert
my_lv my_vg -wi-a---- 452.00m
...

e. Create an ext4 file system on the logical volume my_lv.

# mkfs.ext4 /dev/my_vg/my_lv
mke2fs 1.44.3 (10-July-2018)
Creating filesystem with 462848 1k blocks and 115824 inodes
...

5.2. CONFIGURING AN APACHE HTTP SERVER


The following procedure configures an Apache HTTP server.

1. Ensure that the Apache HTTP server is installed on each node in the cluster. You also need the
wget tool installed on the cluster to be able to check the status of the Apache HTTP server.
On each node, execute the following command.

# yum install -y httpd wget

If you are running the firewalld daemon, on each node in the cluster enable the ports that are
required by the Red Hat High Availability Add-On.

# firewall-cmd --permanent --add-service=high-availability


# firewall-cmd --reload

2. In order for the Apache resource agent to get the status of the Apache HTTP server, ensure
that the following text is present in the /etc/httpd/conf/httpd.conf file on each node in the
cluster, and ensure that it has not been commented out. If this text is not already present, add
the text to the end of the file.

<Location /server-status>
SetHandler server-status
Require local
</Location>

3. When you use the apache resource agent to manage Apache, it does not use systemd.
33
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

3. When you use the apache resource agent to manage Apache, it does not use systemd.
Because of this, you must edit the logrotate script supplied with Apache so that it does not use
systemctl to reload Apache.
Remove the following line in the /etc/logrotate.d/httpd file on each node in the cluster.

/bin/systemctl reload httpd.service > /dev/null 2>/dev/null || true

Replace the line you removed with the following line.

/usr/sbin/httpd -f /etc/httpd/conf/httpd.conf -c "PidFile /var/run/httpd.pid" -k graceful > /dev/null


2>/dev/null || true

4. Create a web page for Apache to serve up. On one node in the cluster, mount the file system
you created in Configuring an LVM volume with an ext4 file system , create the file index.html
on that file system, and then unmount the file system.

# mount /dev/my_vg/my_lv /var/www/


# mkdir /var/www/html
# mkdir /var/www/cgi-bin
# mkdir /var/www/error
# restorecon -R /var/www
# cat <<-END >/var/www/html/index.html
<html>
<body>Hello</body>
</html>
END
# umount /var/www

5.3. CREATING THE RESOURCES AND RESOURCE GROUPS


This use case requires that you create four cluster resources. To ensure these resources all run on the
same node, they are configured as part of the resource group apachegroup. The resources to create
are as follows, listed in the order in which they will start.

1. An LVM resource named my_lvm that uses the LVM volume group you created in Configuring
an LVM volume with an ext4 file system.

2. A Filesystem resource named my_fs, that uses the file system device /dev/my_vg/my_lv you
created in Configuring an LVM volume with an ext4 file system .

3. An IPaddr2 resource, which is a floating IP address for the apachegroup resource group. The IP
address must not be one already associated with a physical node. If the IPaddr2 resource’s NIC
device is not specified, the floating IP must reside on the same network as one of the node’s
statically assigned IP addresses, otherwise the NIC device to assign the floating IP address
cannot be properly detected.

4. An apache resource named Website that uses the index.html file and the Apache
configuration you defined in Configuring an Apache HTTP server .

The following procedure creates the resource group apachegroup and the resources that the group
contains. The resources will start in the order in which you add them to the group, and they will stop in
the reverse order in which they are added to the group. Run this procedure from one node of the cluster
only.

1. The following command creates the LVM-activate resource my_lvm. Because the resource
34
CHAPTER 5. CONFIGURING AN ACTIVE/PASSIVE APACHE HTTP SERVER IN A RED HAT HIGH AVAILABILITY CLUSTER

1. The following command creates the LVM-activate resource my_lvm. Because the resource
group apachegroup does not yet exist, this command creates the resource group.

NOTE

Do not configure more than one LVM-activate resource that uses the same LVM
volume group in an active/passive HA configuration, as this could cause data
corruption. Additionally, do not configure an LVM-activate resource as a clone
resource in an active/passive HA configuration.

[root@z1 ~]# pcs resource create my_lvm ocf:heartbeat:LVM-activate vgname=my_vg


vg_access_mode=system_id --group apachegroup

When you create a resource, the resource is started automatically. You can use the following
command to confirm that the resource was created and has started.

# pcs resource status


Resource Group: apachegroup
my_lvm (ocf::heartbeat:LVM-activate): Started

You can manually stop and start an individual resource with the pcs resource disable and pcs
resource enable commands.

2. The following commands create the remaining resources for the configuration, adding them to
the existing resource group apachegroup.

[root@z1 ~]# pcs resource create my_fs Filesystem \


device="/dev/my_vg/my_lv" directory="/var/www" fstype="ext4" \
--group apachegroup

[root@z1 ~]# pcs resource create VirtualIP IPaddr2 ip=198.51.100.3 \


cidr_netmask=24 --group apachegroup

[root@z1 ~]# pcs resource create Website apache \


configfile="/etc/httpd/conf/httpd.conf" \
statusurl="http://127.0.0.1/server-status" --group apachegroup

3. After creating the resources and the resource group that contains them, you can check the
status of the cluster. Note that all four resources are running on the same node.

[root@z1 ~]# pcs status


Cluster name: my_cluster
Last updated: Wed Jul 31 16:38:51 2013
Last change: Wed Jul 31 16:42:14 2013 via crm_attribute on z1.example.com
Stack: corosync
Current DC: z2.example.com (2) - partition with quorum
Version: 1.1.10-5.el7-9abe687
2 Nodes configured
6 Resources configured

Online: [ z1.example.com z2.example.com ]

Full list of resources:


myapc (stonith:fence_apc_snmp): Started z1.example.com

35
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Resource Group: apachegroup


my_lvm (ocf::heartbeat:LVM): Started z1.example.com
my_fs (ocf::heartbeat:Filesystem): Started z1.example.com
VirtualIP (ocf::heartbeat:IPaddr2): Started z1.example.com
Website (ocf::heartbeat:apache): Started z1.example.com

Note that if you have not configured a fencing device for your cluster, by default the resources
do not start.

4. Once the cluster is up and running, you can point a browser to the IP address you defined as the
IPaddr2 resource to view the sample display, consisting of the simple word "Hello".

Hello

If you find that the resources you configured are not running, you can run the pcs resource
debug-start resource command to test the resource configuration.

5.4. TESTING THE RESOURCE CONFIGURATION


In the cluster status display shown in Creating the resources and resource groups , all of the resources
are running on node z1.example.com. You can test whether the resource group fails over to node
z2.example.com by using the following procedure to put the first node in standby mode, after which
the node will no longer be able to host resources.

1. The following command puts node z1.example.com in standby mode.

[root@z1 ~]# pcs node standby z1.example.com

2. After putting node z1 in standby mode, check the cluster status. Note that the resources
should now all be running on z2.

[root@z1 ~]# pcs status


Cluster name: my_cluster
Last updated: Wed Jul 31 17:16:17 2013
Last change: Wed Jul 31 17:18:34 2013 via crm_attribute on z1.example.com
Stack: corosync
Current DC: z2.example.com (2) - partition with quorum
Version: 1.1.10-5.el7-9abe687
2 Nodes configured
6 Resources configured

Node z1.example.com (1): standby


Online: [ z2.example.com ]

Full list of resources:

myapc (stonith:fence_apc_snmp): Started z1.example.com


Resource Group: apachegroup
my_lvm (ocf::heartbeat:LVM): Started z2.example.com
my_fs (ocf::heartbeat:Filesystem): Started z2.example.com
VirtualIP (ocf::heartbeat:IPaddr2): Started z2.example.com
Website (ocf::heartbeat:apache): Started z2.example.com

The web site at the defined IP address should still display, without interruption.

36
CHAPTER 5. CONFIGURING AN ACTIVE/PASSIVE APACHE HTTP SERVER IN A RED HAT HIGH AVAILABILITY CLUSTER

3. To remove z1 from standby mode, enter the following command.

[root@z1 ~]# pcs cluster unstandby z1.example.com

NOTE

Removing a node from standby mode does not in itself cause the resources to
fail back over to that node.

37
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 6. CONFIGURING AN ACTIVE/PASSIVE NFS


SERVER IN A RED HAT HIGH AVAILABILITY CLUSTER
The following procedure configures a highly available active/passive NFS server on a two-node Red Hat
Enterprise Linux High Availability Add-On cluster using shared storage. The procedure uses pcs to
configure Pacemaker cluster resources. In this use case, clients access the NFS file system through a
floating IP address. The NFS server runs on one of two nodes in the cluster. If the node on which the
NFS server is running becomes inoperative, the NFS server starts up again on the second node of the
cluster with minimal service interruption.

6.1. PREREQUISITES
This use case requires that your system include the following components:

A two-node Red Hat High Availability cluster with power fencing configured for each node. We
recommend but do not require a private network. This procedure uses the cluster example
provided in Creating a Red Hat High-Availability cluster with Pacemaker .

A public virtual IP address, required for the NFS server.

Shared storage for the nodes in the cluster, using iSCSI or Fibre Channel.

6.2. PROCEDURAL OVERVIEW


Configuring a highly available active/passive NFS server on an existing two-node Red Hat Enterprise
Linux High Availability cluster requires that you perform the following steps:

1. Configure an ext4 file system on the LVM logical volume my_lv on the shared storage for the
nodes in the cluster.

2. Configure an NFS share on the shared storage on the LVM logical volume.

3. Create the cluster resources.

4. Test the NFS server you have configured.

6.3. CONFIGURING AN LVM VOLUME WITH AN EXT4 FILE SYSTEM IN


A PACEMAKER CLUSTER
This use case requires that you create an LVM logical volume on storage that is shared between the
nodes of the cluster.

NOTE

LVM volumes and the corresponding partitions and devices used by cluster nodes must
be connected to the cluster nodes only.

The following procedure creates an LVM logical volume and then creates an ext4 file system on that
volume for use in a Pacemaker cluster. In this example, the shared partition /dev/sdb1 is used to store
the LVM physical volume from which the LVM logical volume will be created.

1. On both nodes of the cluster, perform the following steps to set the value for the LVM system

38
CHAPTER 6. CONFIGURING AN ACTIVE/PASSIVE NFS SERVER IN A RED HAT HIGH AVAILABILITY CLUSTER

1. On both nodes of the cluster, perform the following steps to set the value for the LVM system
ID to the value of the uname identifier for the system. The LVM system ID will be used to
ensure that only the cluster is capable of activating the volume group.

a. Set the system_id_source configuration option in the /etc/lvm/lvm.conf configuration file


to uname.

# Configuration option global/system_id_source.


system_id_source = "uname"

b. Verify that the LVM system ID on the node matches the uname for the node.

# lvm systemid
system ID: z1.example.com
# uname -n
z1.example.com

2. Create the LVM volume and create an ext4 file system on that volume. Since the /dev/sdb1
partition is storage that is shared, you perform this part of the procedure on one node only.

a. Create an LVM physical volume on partition /dev/sdb1.

# pvcreate /dev/sdb1
Physical volume "/dev/sdb1" successfully created

b. Create the volume group my_vg that consists of the physical volume /dev/sdb1.

# vgcreate my_vg /dev/sdb1


Volume group "my_vg" successfully created

c. Verify that the new volume group has the system ID of the node on which you are running
and from which you created the volume group.

# vgs -o+systemid
VG #PV #LV #SN Attr VSize VFree System ID
my_vg 1 0 0 wz--n- <1.82t <1.82t z1.example.com

d. Create a logical volume using the volume group my_vg.

# lvcreate -L450 -n my_lv my_vg


Rounding up size to full physical extent 452.00 MiB
Logical volume "my_lv" created

You can use the lvs command to display the logical volume.

# lvs
LV VG Attr LSize Pool Origin Data% Move Log Copy% Convert
my_lv my_vg -wi-a---- 452.00m
...

e. Create an ext4 file system on the logical volume my_lv.

# mkfs.ext4 /dev/my_vg/my_lv
mke2fs 1.44.3 (10-July-2018)

39
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Creating filesystem with 462848 1k blocks and 115824 inodes


...

6.4. CONFIGURING AN NFS SHARE


The following procedure configures the NFS share for the NFS service failover.

1. On both nodes in the cluster, create the /nfsshare directory.

# mkdir /nfsshare

2. On one node in the cluster, perform the following procedure.

a. Mount the ext4 file system that you created in Configuring an LVM volume with an ext4 file
system on the /nfsshare directory.

[root@z1 ~]# mount /dev/my_vg/my_lv /nfsshare

b. Create an exports directory tree on the /nfsshare directory.

[root@z1 ~]# mkdir -p /nfsshare/exports


[root@z1 ~]# mkdir -p /nfsshare/exports/export1
[root@z1 ~]# mkdir -p /nfsshare/exports/export2

c. Place files in the exports directory for the NFS clients to access. For this example, we are
creating test files named clientdatafile1 and clientdatafile2.

[root@z1 ~]# touch /nfsshare/exports/export1/clientdatafile1


[root@z1 ~]# touch /nfsshare/exports/export2/clientdatafile2

d. Unmount the ext4 file system and deactivate the LVM volume group.

[root@z1 ~]# umount /dev/my_vg/my_lv


[root@z1 ~]# vgchange -an my_vg

6.5. CONFIGURING THE RESOURCES AND RESOURCE GROUP FOR AN


NFS SERVER IN A CLUSTER
This section provides the procedure for configuring the cluster resources for this use case.

NOTE

If you have not configured a fencing device for your cluster, by default the resources do
not start.

If you find that the resources you configured are not running, you can run the pcs
resource debug-start resource command to test the resource configuration. This starts
the service outside of the cluster’s control and knowledge. At the point the configured
resources are running again, run pcs resource cleanup resource to make the cluster
aware of the updates.

The following procedure configures the system resources. To ensure these resources all run on the

40
CHAPTER 6. CONFIGURING AN ACTIVE/PASSIVE NFS SERVER IN A RED HAT HIGH AVAILABILITY CLUSTER

same node, they are configured as part of the resource group nfsgroup. The resources will start in the
order in which you add them to the group, and they will stop in the reverse order in which they are added
to the group. Run this procedure from one node of the cluster only.

1. Create the LVM-activate resource named my_lvm. Because the resource group nfsgroup
does not yet exist, this command creates the resource group.


WARNING

Do not configure more than one LVM-activate resource that uses the same
LVM volume group in an active/passive HA configuration, as this risks data
corruption. Additionally, do not configure an LVM-activate resource as a
clone resource in an active/passive HA configuration.

[root@z1 ~]# pcs resource create my_lvm ocf:heartbeat:LVM-activate vgname=my_vg


vg_access_mode=system_id --group nfsgroup

2. Check the status of the cluster to verify that the resource is running.

root@z1 ~]# pcs status


Cluster name: my_cluster
Last updated: Thu Jan 8 11:13:17 2015
Last change: Thu Jan 8 11:13:08 2015
Stack: corosync
Current DC: z2.example.com (2) - partition with quorum
Version: 1.1.12-a14efad
2 Nodes configured
3 Resources configured

Online: [ z1.example.com z2.example.com ]

Full list of resources:


myapc (stonith:fence_apc_snmp): Started z1.example.com
Resource Group: nfsgroup
my_lvm (ocf::heartbeat:LVM): Started z1.example.com

PCSD Status:
z1.example.com: Online
z2.example.com: Online

Daemon Status:
corosync: active/enabled
pacemaker: active/enabled
pcsd: active/enabled

3. Configure a Filesystem resource for the cluster.


The following command configures an ext4 Filesystem resource named nfsshare as part of
the nfsgroup resource group. This file system uses the LVM volume group and ext4 file system
you created in Configuring an LVM volume with an ext4 file system and will be mounted on the
/nfsshare directory you created in Configuring an NFS share .

41
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

[root@z1 ~]# pcs resource create nfsshare Filesystem \


device=/dev/my_vg/my_lv directory=/nfsshare \
fstype=ext4 --group nfsgroup

You can specify mount options as part of the resource configuration for a Filesystem resource
with the options=options parameter. Run the pcs resource describe Filesystem command
for full configuration options.

4. Verify that the my_lvm and nfsshare resources are running.

[root@z1 ~]# pcs status


...
Full list of resources:
myapc (stonith:fence_apc_snmp): Started z1.example.com
Resource Group: nfsgroup
my_lvm (ocf::heartbeat:LVM): Started z1.example.com
nfsshare (ocf::heartbeat:Filesystem): Started z1.example.com
...

5. Create the nfsserver resource named nfs-daemon as part of the resource group nfsgroup.

NOTE

The nfsserver resource allows you to specify an nfs_shared_infodir parameter,


which is a directory that NFS servers use to store NFS-related stateful
information.

It is recommended that this attribute be set to a subdirectory of one of the


Filesystem resources you created in this collection of exports. This ensures that
the NFS servers are storing their stateful information on a device that will
become available to another node if this resource group needs to relocate. In this
example;

/nfsshare is the shared-storage directory managed by the Filesystem


resource

/nfsshare/exports/export1 and /nfsshare/exports/export2 are the export


directories

/nfsshare/nfsinfo is the shared-information directory for the nfsserver


resource

[root@z1 ~]# pcs resource create nfs-daemon nfsserver \


nfs_shared_infodir=/nfsshare/nfsinfo nfs_no_notify=true \
--group nfsgroup

[root@z1 ~]# pcs status


...

6. Add the exportfs resources to export the /nfsshare/exports directory. These resources are
part of the resource group nfsgroup. This builds a virtual directory for NFSv4 clients. NFSv3
clients can access these exports as well.

NOTE
42
CHAPTER 6. CONFIGURING AN ACTIVE/PASSIVE NFS SERVER IN A RED HAT HIGH AVAILABILITY CLUSTER

NOTE

The fsid=0 option is required only if you want to create a virtual directory for
NFSv4 clients. For more information, see How do I configure the fsid option in an
NFS server’s /etc/exports file?.

[root@z1 ~]# pcs resource create nfs-root exportfs \


clientspec=192.168.122.0/255.255.255.0 \
options=rw,sync,no_root_squash \
directory=/nfsshare/exports \
fsid=0 --group nfsgroup

[root@z1 ~]# # pcs resource create nfs-export1 exportfs \


clientspec=192.168.122.0/255.255.255.0 \
options=rw,sync,no_root_squash directory=/nfsshare/exports/export1 \
fsid=1 --group nfsgroup

[root@z1 ~]# # pcs resource create nfs-export2 exportfs \


clientspec=192.168.122.0/255.255.255.0 \
options=rw,sync,no_root_squash directory=/nfsshare/exports/export2 \
fsid=2 --group nfsgroup

7. Add the floating IP address resource that NFS clients will use to access the NFS share. This
resource is part of the resource group nfsgroup. For this example deployment, we are using
192.168.122.200 as the floating IP address.

[root@z1 ~]# pcs resource create nfs_ip IPaddr2 \


ip=192.168.122.200 cidr_netmask=24 --group nfsgroup

8. Add an nfsnotify resource for sending NFSv3 reboot notifications once the entire NFS
deployment has initialized. This resource is part of the resource group nfsgroup.

NOTE

For the NFS notification to be processed correctly, the floating IP address must
have a host name associated with it that is consistent on both the NFS servers
and the NFS client.

[root@z1 ~]# pcs resource create nfs-notify nfsnotify \


source_host=192.168.122.200 --group nfsgroup

9. After creating the resources and the resource constraints, you can check the status of the
cluster. Note that all resources are running on the same node.

[root@z1 ~]# pcs status


...
Full list of resources:
myapc (stonith:fence_apc_snmp): Started z1.example.com
Resource Group: nfsgroup
my_lvm (ocf::heartbeat:LVM): Started z1.example.com
nfsshare (ocf::heartbeat:Filesystem): Started z1.example.com
nfs-daemon (ocf::heartbeat:nfsserver): Started z1.example.com
nfs-root (ocf::heartbeat:exportfs): Started z1.example.com

43
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

nfs-export1 (ocf::heartbeat:exportfs): Started z1.example.com


nfs-export2 (ocf::heartbeat:exportfs): Started z1.example.com
nfs_ip (ocf::heartbeat:IPaddr2): Started z1.example.com
nfs-notify (ocf::heartbeat:nfsnotify): Started z1.example.com
...

6.6. TESTING THE NFS RESOURCE CONFIGURATION


You can validate your system configuration with the following procedures. You should be able to mount
the exported file system with either NFSv3 or NFSv4.

6.6.1. Testing the NFS export


1. On a node outside of the cluster, residing in the same network as the deployment, verify that
the NFS share can be seen by mounting the NFS share. For this example, we are using the
192.168.122.0/24 network.

# showmount -e 192.168.122.200
Export list for 192.168.122.200:
/nfsshare/exports/export1 192.168.122.0/255.255.255.0
/nfsshare/exports 192.168.122.0/255.255.255.0
/nfsshare/exports/export2 192.168.122.0/255.255.255.0

2. To verify that you can mount the NFS share with NFSv4, mount the NFS share to a directory on
the client node. After mounting, verify that the contents of the export directories are visible.
Unmount the share after testing.

# mkdir nfsshare
# mount -o "vers=4" 192.168.122.200:export1 nfsshare
# ls nfsshare
clientdatafile1
# umount nfsshare

3. Verify that you can mount the NFS share with NFSv3. After mounting, verify that the test file
clientdatafile1 is visible. Unlike NFSv4, since NFSv3 does not use the virtual file system, you
must mount a specific export. Unmount the share after testing.

# mkdir nfsshare
# mount -o "vers=3" 192.168.122.200:/nfsshare/exports/export2 nfsshare
# ls nfsshare
clientdatafile2
# umount nfsshare

6.6.2. Testing for failover


1. On a node outside of the cluster, mount the NFS share and verify access to the clientdatafile1
we created in Configuring an NFS share

# mkdir nfsshare
# mount -o "vers=4" 192.168.122.200:export1 nfsshare
# ls nfsshare
clientdatafile1

2. From a node within the cluster, determine which node in the cluster is running nfsgroup. In this
44
CHAPTER 6. CONFIGURING AN ACTIVE/PASSIVE NFS SERVER IN A RED HAT HIGH AVAILABILITY CLUSTER

2. From a node within the cluster, determine which node in the cluster is running nfsgroup. In this
example, nfsgroup is running on z1.example.com.

[root@z1 ~]# pcs status


...
Full list of resources:
myapc (stonith:fence_apc_snmp): Started z1.example.com
Resource Group: nfsgroup
my_lvm (ocf::heartbeat:LVM): Started z1.example.com
nfsshare (ocf::heartbeat:Filesystem): Started z1.example.com
nfs-daemon (ocf::heartbeat:nfsserver): Started z1.example.com
nfs-root (ocf::heartbeat:exportfs): Started z1.example.com
nfs-export1 (ocf::heartbeat:exportfs): Started z1.example.com
nfs-export2 (ocf::heartbeat:exportfs): Started z1.example.com
nfs_ip (ocf::heartbeat:IPaddr2): Started z1.example.com
nfs-notify (ocf::heartbeat:nfsnotify): Started z1.example.com
...

3. From a node within the cluster, put the node that is running nfsgroup in standby mode.

[root@z1 ~]# pcs node standby z1.example.com

4. Verify that nfsgroup successfully starts on the other cluster node.

[root@z1 ~]# pcs status


...
Full list of resources:
Resource Group: nfsgroup
my_lvm (ocf::heartbeat:LVM): Started z2.example.com
nfsshare (ocf::heartbeat:Filesystem): Started z2.example.com
nfs-daemon (ocf::heartbeat:nfsserver): Started z2.example.com
nfs-root (ocf::heartbeat:exportfs): Started z2.example.com
nfs-export1 (ocf::heartbeat:exportfs): Started z2.example.com
nfs-export2 (ocf::heartbeat:exportfs): Started z2.example.com
nfs_ip (ocf::heartbeat:IPaddr2): Started z2.example.com
nfs-notify (ocf::heartbeat:nfsnotify): Started z2.example.com
...

5. From the node outside the cluster on which you have mounted the NFS share, verify that this
outside node still continues to have access to the test file within the NFS mount.

# ls nfsshare
clientdatafile1

Service will be lost briefly for the client during the failover but the client should recover it with no
user intervention. By default, clients using NFSv4 may take up to 90 seconds to recover the
mount; this 90 seconds represents the NFSv4 file lease grace period observed by the server on
startup. NFSv3 clients should recover access to the mount in a matter of a few seconds.

6. From a node within the cluster, remove the node that was initially running running nfsgroup
from standby mode. This will not in itself move the cluster resources back to this node.

[root@z1 ~]# pcs cluster unstandby z1.example.com

45
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 7. GFS2 FILE SYSTEMS IN A CLUSTER


This section provides:

A procedure to set up a Pacemaker cluster that includes GFS2 file systems

A procedure to migrate RHEL 7 logical volumes that contain GFS2 file systems to a RHEL 8
cluster

7.1. CONFIGURING A GFS2 FILE SYSTEM IN A CLUSTER


This procedure is an outline of the steps required to set up a Pacemaker cluster that includes GFS2 file
systems. This example creates three GFS2 file systems on three logical volumes.

As a prerequisite for this procedure, you must install and start the cluster software on all nodes and
create a basic two-node cluster. You must also configure fencing for the cluster. For information on
creating a Pacemaker cluster and configuring fencing for the cluster, see Creating a Red Hat High-
Availability cluster with Pacemaker.

1. On both nodes of the cluster, install the lvm2-lockd, gfs2-utils, and dlm packages. The lvm2-
lockd package is part of the AppStream channel and the gfs2-utils and dlm packages are part
of the Resilient Storage channel.

# yum install lvm2-lockd gfs2-utils dlm

2. Set up a dlm resource. This is a required dependency for configuring a GFS2 file system in a
cluster. This example creates the dlm resource as part of a resource group named locking.

[root@z1 ~]# pcs resource create dlm --group locking ocf:pacemaker:controld op


monitor interval=30s on-fail=fence

3. Clone the locking resource group so that the resource group can be active on both nodes of
the cluster.

[root@z1 ~]# pcs resource clone locking interleave=true

4. Set up an lvmlockd resource as part of the group locking.

[root@z1 ~]# pcs resource create lvmlockd --group locking ocf:heartbeat:lvmlockd op


monitor interval=30s on-fail=fence

5. Check the status of the cluster to ensure that the locking resource group has started on both
nodes of the cluster.

[root@z1 ~]# pcs status --full


Cluster name: my_cluster
[...]

Online: [ z1.example.com (1) z2.example.com (2) ]

Full list of resources:

smoke-apc (stonith:fence_apc): Started z1.example.com


Clone Set: locking-clone [locking]

46
CHAPTER 7. GFS2 FILE SYSTEMS IN A CLUSTER

Resource Group: locking:0


dlm (ocf::pacemaker:controld): Started z1.example.com
lvmlockd (ocf::heartbeat:lvmlockd): Started z1.example.com
Resource Group: locking:1
dlm (ocf::pacemaker:controld): Started z2.example.com
lvmlockd (ocf::heartbeat:lvmlockd): Started z2.example.com
Started: [ z1.example.com z2.example.com ]

6. Verify that the lvmlockd daemon is running on both nodes of the cluster.

[root@z1 ~]# ps -ef | grep lvmlockd


root 12257 1 0 17:45 ? 00:00:00 lvmlockd -p /run/lvmlockd.pid -A 1 -g dlm
[root@z2 ~]# ps -ef | grep lvmlockd
root 12270 1 0 17:45 ? 00:00:00 lvmlockd -p /run/lvmlockd.pid -A 1 -g dlm

7. On one node of the cluster, create two shared volume groups. One volume group will contain
two GFS2 file systems, and the other volume group will contain one GFS2 file system.
The following command creates the shared volume group shared_vg1 on /dev/vdb.

[root@z1 ~]# vgcreate --shared shared_vg1 /dev/vdb


Physical volume "/dev/vdb" successfully created.
Volume group "shared_vg1" successfully created
VG shared_vg1 starting dlm lockspace
Starting locking. Waiting until locks are ready...

The following command creates the shared volume group shared_vg2 on /dev/vdc.

[root@z1 ~]# vgcreate --shared shared_vg2 /dev/vdc


Physical volume "/dev/vdc" successfully created.
Volume group "shared_vg2" successfully created
VG shared_vg2 starting dlm lockspace
Starting locking. Waiting until locks are ready...

8. On the second node in the cluster, start the lock manager for each of the shared volume groups.

[root@z2 ~]# vgchange --lock-start shared_vg1


VG shared_vg1 starting dlm lockspace
Starting locking. Waiting until locks are ready...
[root@z2 ~]# vgchange --lock-start shared_vg2
VG shared_vg2 starting dlm lockspace
Starting locking. Waiting until locks are ready...

9. On one node in the cluster, create the shared logical volumes and format the volumes with a
GFS2 file system. One journal is required for each node that mounts the file system. Ensure that
you create enough journals for each of the nodes in your cluster.

[root@z1 ~]# lvcreate --activate sy -L5G -n shared_lv1 shared_vg1


Logical volume "shared_lv1" created.
[root@z1 ~]# lvcreate --activate sy -L5G -n shared_lv2 shared_vg1
Logical volume "shared_lv2" created.
[root@z1 ~]# lvcreate --activate sy -L5G -n shared_lv1 shared_vg2
Logical volume "shared_lv1" created.

[root@z1 ~]# mkfs.gfs2 -j2 -p lock_dlm -t my_cluster:gfs2-demo1

47
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

/dev/shared_vg1/shared_lv1
[root@z1 ~]# mkfs.gfs2 -j2 -p lock_dlm -t my_cluster:gfs2-demo2
/dev/shared_vg1/shared_lv2
[root@z1 ~]# mkfs.gfs2 -j2 -p lock_dlm -t my_cluster:gfs2-demo3
/dev/shared_vg2/shared_lv1

10. Create an LVM-activate resource for each logical volume to automatically activate that logical
volume on all nodes.

a. Create an LVM-activate resource named sharedlv1 for the logical volume shared_lv1 in
volume group shared_vg1. This command also creates the resource group shared_vg1
that includes the resource. In this example, the resource group has the same name as the
shared volume group that includes the logical volume.

[root@z1 ~]# pcs resource create sharedlv1 --group shared_vg1 ocf:heartbeat:LVM-


activate lvname=shared_lv1 vgname=shared_vg1 activation_mode=shared
vg_access_mode=lvmlockd

b. Create an LVM-activate resource named sharedlv2 for the logical volume shared_lv2 in
volume group shared_vg1. This resource will also be part of the resource group
shared_vg1.

[root@z1 ~]# pcs resource create sharedlv2 --group shared_vg1 ocf:heartbeat:LVM-


activate lvname=shared_lv2 vgname=shared_vg1 activation_mode=shared
vg_access_mode=lvmlockd

c. Create an LVM-activate resource named sharedlv3 for the logical volume shared_lv1 in
volume group shared_vg2. This command also creates the resource group shared_vg2
that includes the resource.

[root@z1 ~]# pcs resource create sharedlv3 --group shared_vg2 ocf:heartbeat:LVM-


activate lvname=shared_lv1 vgname=shared_vg2 activation_mode=shared
vg_access_mode=lvmlockd

11. Clone the two new resource groups.

[root@z1 ~]# pcs resource clone shared_vg1 interleave=true


[root@z1 ~]# pcs resource clone shared_vg2 interleave=true

12. Configure ordering constraints to ensure that the locking resource group that includes the dlm
and lvmlockd resources starts first.

[root@z1 ~]# pcs constraint order start locking-clone then shared_vg1-clone


Adding locking-clone shared_vg1-clone (kind: Mandatory) (Options: first-action=start then-
action=start)
[root@z1 ~]# pcs constraint order start locking-clone then shared_vg2-clone
Adding locking-clone shared_vg2-clone (kind: Mandatory) (Options: first-action=start then-
action=start)

13. On both nodes in the cluster, verify that the logical volumes are active. There may be a delay of
a few seconds.

[root@z1 ~]# lvs


LV VG Attr LSize

48
CHAPTER 7. GFS2 FILE SYSTEMS IN A CLUSTER

shared_lv1 shared_vg1 -wi-a----- 5.00g


shared_lv2 shared_vg1 -wi-a----- 5.00g
shared_lv1 shared_vg2 -wi-a----- 5.00g

[root@z2 ~]# lvs


LV VG Attr LSize
shared_lv1 shared_vg1 -wi-a----- 5.00g
shared_lv2 shared_vg1 -wi-a----- 5.00g
shared_lv1 shared_vg2 -wi-a----- 5.00g

14. Create a file system resource to automatically mount each GFS2 file system on all nodes.
You should not add the file system to the /etc/fstab file because it will be managed as a
Pacemaker cluster resource. Mount options can be specified as part of the resource
configuration with options=options. Run the pcs resource describe Filesystem command for
full configuration options.

The following commands create the file system resources. These commands add each resource
to the resource group that includes the logical volume resource for that file system.

[root@z1 ~]# pcs resource create sharedfs1 --group shared_vg1


ocf:heartbeat:Filesystem device="/dev/shared_vg1/shared_lv1" directory="/mnt/gfs1"
fstype="gfs2" options=noatime op monitor interval=10s on-fail=fence
[root@z1 ~]# pcs resource create sharedfs2 --group shared_vg1
ocf:heartbeat:Filesystem device="/dev/shared_vg1/shared_lv2" directory="/mnt/gfs2"
fstype="gfs2" options=noatime op monitor interval=10s on-fail=fence
[root@z1 ~]# pcs resource create sharedfs3 --group shared_vg2
ocf:heartbeat:Filesystem device="/dev/shared_vg2/shared_lv1" directory="/mnt/gfs3"
fstype="gfs2" options=noatime op monitor interval=10s on-fail=fence

15. Verify that the GFS2 file systems are mounted on both nodes of the cluster.

[root@z1 ~]# mount | grep gfs2


/dev/mapper/shared_vg1-shared_lv1 on /mnt/gfs1 type gfs2 (rw,noatime,seclabel)
/dev/mapper/shared_vg1-shared_lv2 on /mnt/gfs2 type gfs2 (rw,noatime,seclabel)
/dev/mapper/shared_vg2-shared_lv1 on /mnt/gfs3 type gfs2 (rw,noatime,seclabel)

[root@z2 ~]# mount | grep gfs2


/dev/mapper/shared_vg1-shared_lv1 on /mnt/gfs1 type gfs2 (rw,noatime,seclabel)
/dev/mapper/shared_vg1-shared_lv2 on /mnt/gfs2 type gfs2 (rw,noatime,seclabel)
/dev/mapper/shared_vg2-shared_lv1 on /mnt/gfs3 type gfs2 (rw,noatime,seclabel)

16. Check the status of the cluster.

[root@z1 ~]# pcs status --full


Cluster name: my_cluster
[...1

Full list of resources:

smoke-apc (stonith:fence_apc): Started z1.example.com


Clone Set: locking-clone [locking]
Resource Group: locking:0
dlm (ocf::pacemaker:controld): Started z2.example.com
lvmlockd (ocf::heartbeat:lvmlockd): Started z2.example.com
Resource Group: locking:1

49
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

dlm (ocf::pacemaker:controld): Started z1.example.com


lvmlockd (ocf::heartbeat:lvmlockd): Started z1.example.com
Started: [ z1.example.com z2.example.com ]
Clone Set: shared_vg1-clone [shared_vg1]
Resource Group: shared_vg1:0
sharedlv1 (ocf::heartbeat:LVM-activate): Started z2.example.com
sharedlv2 (ocf::heartbeat:LVM-activate): Started z2.example.com
sharedfs1 (ocf::heartbeat:Filesystem): Started z2.example.com
sharedfs2 (ocf::heartbeat:Filesystem): Started z2.example.com
Resource Group: shared_vg1:1
sharedlv1 (ocf::heartbeat:LVM-activate): Started z1.example.com
sharedlv2 (ocf::heartbeat:LVM-activate): Started z1.example.com
sharedfs1 (ocf::heartbeat:Filesystem): Started z1.example.com
sharedfs2 (ocf::heartbeat:Filesystem): Started example.co
Started: [ z1.example.com z2.example.com ]
Clone Set: shared_vg2-clone [shared_vg2]
Resource Group: shared_vg2:0
sharedlv3 (ocf::heartbeat:LVM-activate): Started z2.example.com
sharedfs3 (ocf::heartbeat:Filesystem): Started z2.example.com
Resource Group: shared_vg2:1
sharedlv3 (ocf::heartbeat:LVM-activate): Started z1.example.com
sharedfs3 (ocf::heartbeat:Filesystem): Started z1.example.com
Started: [ z1.example.com z2.example.com ]

...

7.2. MIGRATING A GFS2 FILE SYSTEM FROM RHEL7 TO RHEL8


In Red Hat Enterprise Linux 8, LVM uses the LVM lock daemon lvmlockd instead of clvmd for
managing shared storage devices in an active/active cluster. This requires that you configure the logical
volumes that your active/active cluster will require as shared logical volumes. Additionally, this requires
that you use the LVM-activate resource to manage an LVM volume and that you use the lvmlockd
resource agent to manage the lvmlockd daemon. See Configuring a GFS2 file system in a cluster for a
full procedure for configuring a Pacemaker cluster that includes GFS2 file systems using shared logical
volumes.

To use your existing Red Hat Enterprise Linux 7 logical volumes when configuring a RHEL8 cluster that
includes GFS2 file systems, perform the following procedure from the RHEL8 cluster. In this example,
the clustered RHEL 7 logical volume is part of the volume group upgrade_gfs_vg.

NOTE

The RHEL8 cluster must have the same name as the RHEL7 cluster that includes the
GFS2 file system in order for the existing file system to be valid.

1. Ensure that the logical volumes containing the GFS2 file systems are currently inactive. This
procedure is safe only if all nodes have stopped using the volume group.

2. From one node in the cluster, forcibly change the volume group to be local.

[root@rhel8-01 ~]# vgchange --lock-type none --lock-opt force upgrade_gfs_vg


Forcibly change VG lock type to none? [y/n]: y
Volume group "upgrade_gfs_vg" successfully changed

50
CHAPTER 7. GFS2 FILE SYSTEMS IN A CLUSTER

3. From one node in the cluster, change the local volume group to a shared volume group

[root@rhel8-01 ~]# vgchange --lock-type dlm upgrade_gfs_vg


Volume group "upgrade_gfs_vg" successfully changed

4. On each node in the cluster, start locking for the volume group.

[root@rhel8-01 ~]# vgchange --lock-start upgrade_gfs_vg


VG upgrade_gfs_vg starting dlm lockspace
Starting locking. Waiting until locks are ready...
[root@rhel8-02 ~]# vgchange --lock-start upgrade_gfs_vg
VG upgrade_gfs_vg starting dlm lockspace
Starting locking. Waiting until locks are ready...

After performing this procedure, you can create an LVM-activate resource for each logical volume.

51
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 8. CONFIGURING FENCING IN A RED HAT HIGH


AVAILABILITY CLUSTER
A node that is unresponsive may still be accessing data. The only way to be certain that your data is safe
is to fence the node using STONITH. STONITH is an acronym for "Shoot The Other Node In The Head"
and it protects your data from being corrupted by rogue nodes or concurrent access. Using STONITH,
you can be certain that a node is truly offline before allowing the data to be accessed from another
node.

STONITH also has a role to play in the event that a clustered service cannot be stopped. In this case, the
cluster uses STONITH to force the whole node offline, thereby making it safe to start the service
elsewhere.

For more complete general information on fencing and its importance in a Red Hat High Availability
cluster, see Fencing in a Red Hat High Availability Cluster .

You implement STONITH in a Pacemaker cluster by configuring fence devices for the nodes of the
cluster.

8.1. DISPLAYING AVAILABLE FENCE AGENTS AND THEIR OPTIONS


Use the following command to view of list of all available STONITH agents. When you specify a filter, this
command displays only the STONITH agents that match the filter.

pcs stonith list [filter]

Use the following command to view the options for the specified STONITH agent.

pcs stonith describe stonith_agent

For example, the following command displays the options for the fence agent for APC over telnet/SSH.

# pcs stonith describe fence_apc


Stonith options for: fence_apc
ipaddr (required): IP Address or Hostname
login (required): Login Name
passwd: Login password or passphrase
passwd_script: Script to retrieve password
cmd_prompt: Force command prompt
secure: SSH connection
port (required): Physical plug number or name of virtual machine
identity_file: Identity file for ssh
switch: Physical switch number on device
inet4_only: Forces agent to use IPv4 addresses only
inet6_only: Forces agent to use IPv6 addresses only
ipport: TCP port to use for connection with device
action (required): Fencing Action
verbose: Verbose mode
debug: Write debug information to given file
version: Display version information and exit
help: Display help and exit
separator: Separator for CSV created by operation list
power_timeout: Test X seconds for status change after ON/OFF
shell_timeout: Wait X seconds for cmd prompt after issuing command

52
CHAPTER 8. CONFIGURING FENCING IN A RED HAT HIGH AVAILABILITY CLUSTER

login_timeout: Wait X seconds for cmd prompt after login


power_wait: Wait X seconds after issuing ON/OFF
delay: Wait X seconds before fencing is started
retry_on: Count of attempts to retry power on


WARNING

For fence agents that provide a method option, a value of cycle is unsupported and
should not be specified, as it may cause data corruption.

8.2. CREATING A FENCE DEVICE


The format for the command to create a stonith device is as follows. For a listing of the available stonith
creation options, see the pcs stonith -h display.

pcs stonith create stonith_id stonith_device_type [stonith_device_options] [op operation_action


operation_options]

The following command creates a single fencing device for a single node.

# pcs stonith create MyStonith fence_virt pcmk_host_list=f1 op monitor interval=30s

Some fence devices can fence only a single node, while other devices can fence multiple nodes. The
parameters you specify when you create a fencing device depend on what your fencing device supports
and requires.

Some fence devices can automatically determine what nodes they can fence.

You can use the pcmk_host_list parameter when creating a fencing device to specify all of the
machines that are controlled by that fencing device.

Some fence devices require a mapping of host names to the specifications that the fence
device understands. You can map host names with the pcmk_host_map parameter when
creating a fencing device.

For information on the pcmk_host_list and pcmk_host_map parameters, see General Properties of
Fencing Devices.

After configuring a fence device, it is imperative that you test the device to ensure that it is working
correctly. For information on testing a fence device, see Testing a fence device .

8.3. GENERAL PROPERTIES OF FENCING DEVICES


Any cluster node can fence any other cluster node with any fence device, regardless of whether the
fence resource is started or stopped. Whether the resource is started controls only the recurring
monitor for the device, not whether it can be used, with the following exceptions:

You can disable a fencing device by running the pcs stonith disable stonith_id command. This
will prevent any node from using that device.

53
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

To prevent a specific node from using a fencing device, you can configure location constraints
for the fencing resource with the pcs constraint location …​ avoids command.

Configuring stonith-enabled=false will disable fencing altogether. Note, however, that Red Hat
does not support clusters when fencing is disabled, as it is not suitable for a production
environment.

Table 8.1, “General Properties of Fencing Devices” describes the general properties you can set for
fencing devices.

Table 8.1. General Properties of Fencing Devices

Field Type Default Description

pcmk_host_map string A mapping of host names


to port numbers for
devices that do not
support host names. For
example:
node1:1;node2:2,3 tells
the cluster to use port 1 for
node1 and ports 2 and 3 for
node2

pcmk_host_list string A list of machines


controlled by this device
(Optional unless
pcmk_host_check=stat
ic-list ).

pcmk_host_check string * static-list if either How to determine which


pcmk_host_list or machines are controlled by
pcmk_host_map is set the device. Allowed values:
dynamic-list (query the
* Otherwise, dynamic-list device), static-list (check
if the fence device the pcmk_host_list
supports the list action attribute), none (assume
every device can fence
* Otherwise, status if the every machine)
fence device supports the
status action

*Otherwise, none.

8.4. ADVANCED FENCING CONFIGURATION OPTIONS


Table 8.2, “Advanced Properties of Fencing Devices” summarizes additional properties you can set for
fencing devices. Note that these properties are for advanced use only.

Table 8.2. Advanced Properties of Fencing Devices

54
CHAPTER 8. CONFIGURING FENCING IN A RED HAT HIGH AVAILABILITY CLUSTER

Field Type Default Description

pcmk_host_argument string port An alternate parameter to supply instead of


port. Some devices do not support the
standard port parameter or may provide
additional ones. Use this to specify an
alternate, device-specific parameter that
should indicate the machine to be fenced. A
value of none can be used to tell the cluster
not to supply any additional parameters.

pcmk_reboot_action string reboot An alternate command to run instead of


reboot. Some devices do not support the
standard commands or may provide
additional ones. Use this to specify an
alternate, device-specific, command that
implements the reboot action.

pcmk_reboot_timeout time 60s Specify an alternate timeout to use for


reboot actions instead of stonith-timeout.
Some devices need much more/less time to
complete than normal. Use this to specify an
alternate, device-specific, timeout for reboot
actions.

pcmk_reboot_retries integer 2 The maximum number of times to retry the


reboot command within the timeout period.
Some devices do not support multiple
connections. Operations may fail if the
device is busy with another task so
Pacemaker will automatically retry the
operation, if there is time remaining. Use this
option to alter the number of times
Pacemaker retries reboot actions before
giving up.

pcmk_off_action string off An alternate command to run instead of off.


Some devices do not support the standard
commands or may provide additional ones.
Use this to specify an alternate, device-
specific, command that implements the off
action.

pcmk_off_timeout time 60s Specify an alternate timeout to use for off


actions instead of stonith-timeout. Some
devices need much more or much less time
to complete than normal. Use this to specify
an alternate, device-specific, timeout for off
actions.

55
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Field Type Default Description

pcmk_off_retries integer 2 The maximum number of times to retry the


off command within the timeout period.
Some devices do not support multiple
connections. Operations may fail if the
device is busy with another task so
Pacemaker will automatically retry the
operation, if there is time remaining. Use this
option to alter the number of times
Pacemaker retries off actions before giving
up.

pcmk_list_action string list An alternate command to run instead of list.


Some devices do not support the standard
commands or may provide additional ones.
Use this to specify an alternate, device-
specific, command that implements the list
action.

pcmk_list_timeout time 60s Specify an alternate timeout to use for list


actions. Some devices need much more or
much less time to complete than normal. Use
this to specify an alternate, device-specific,
timeout for list actions.

pcmk_list_retries integer 2 The maximum number of times to retry the


list command within the timeout period.
Some devices do not support multiple
connections. Operations may fail if the
device is busy with another task so
Pacemaker will automatically retry the
operation, if there is time remaining. Use this
option to alter the number of times
Pacemaker retries list actions before giving
up.

pcmk_monitor_action string monitor An alternate command to run instead of


monitor. Some devices do not support the
standard commands or may provide
additional ones. Use this to specify an
alternate, device-specific, command that
implements the monitor action.

pcmk_monitor_timeout time 60s Specify an alternate timeout to use for


monitor actions instead of stonith-timeout.
Some devices need much more or much less
time to complete than normal. Use this to
specify an alternate, device-specific, timeout
for monitor actions.

56
CHAPTER 8. CONFIGURING FENCING IN A RED HAT HIGH AVAILABILITY CLUSTER

Field Type Default Description

pcmk_monitor_retries integer 2 The maximum number of times to retry the


monitor command within the timeout
period. Some devices do not support multiple
connections. Operations may fail if the
device is busy with another task so
Pacemaker will automatically retry the
operation, if there is time remaining. Use this
option to alter the number of times
Pacemaker retries monitor actions before
giving up.

pcmk_status_action string status An alternate command to run instead of


status. Some devices do not support the
standard commands or may provide
additional ones. Use this to specify an
alternate, device-specific, command that
implements the status action.

pcmk_status_timeout time 60s Specify an alternate timeout to use for


status actions instead of stonith-timeout.
Some devices need much more or much less
time to complete than normal. Use this to
specify an alternate, device-specific, timeout
for status actions.

pcmk_status_retries integer 2 The maximum number of times to retry the


status command within the timeout period.
Some devices do not support multiple
connections. Operations may fail if the
device is busy with another task so
Pacemaker will automatically retry the
operation, if there is time remaining. Use this
option to alter the number of times
Pacemaker retries status actions before
giving up.

57
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Field Type Default Description

pcmk_delay_base time 0s Enable a base delay for stonith actions and


specify a base delay value. In a cluster with
an even number of nodes, configuring a
delay can help avoid nodes fencing each
other at the same time in an even split. A
random delay can be useful when the same
fence device is used for all nodes, and
differing static delays can be useful on each
fencing device when a separate device is
used for each node. The overall delay is
derived from a random delay value adding
this static delay so that the sum is kept below
the maximum delay. If you set
pcmk_delay_base but do not set
pcmk_delay_max, there is no random
component to the delay and it will be the
value of pcmk_delay_base.

Some individual fence agents implement a


"delay" parameter, which is independent of
delays configured with a pcmk_delay_*
property. If both of these delays are
configured, they are added together and
thus would generally not be used in
conjunction.

pcmk_delay_max time 0s Enable a random delay for stonith actions


and specify the maximum of random delay. In
a cluster with an even number of nodes,
configuring a delay can help avoid nodes
fencing each other at the same time in an
even split. A random delay can be useful
when the same fence device is used for all
nodes, and differing static delays can be
useful on each fencing device when a
separate device is used for each node. The
overall delay is derived from this random
delay value adding a static delay so that the
sum is kept below the maximum delay. If you
set pcmk_delay_max but do not set
pcmk_delay_base there is no static
component to the delay.

Some individual fence agents implement a


"delay" parameter, which is independent of
delays configured with a pcmk_delay_*
property. If both of these delays are
configured, they are added together and
thus would generally not be used in
conjunction.

58
CHAPTER 8. CONFIGURING FENCING IN A RED HAT HIGH AVAILABILITY CLUSTER

Field Type Default Description

pcmk_action_limit integer 1 The maximum number of actions that can be


performed in parallel on this device. The
cluster property concurrent-fencing=true
needs to be configured first. A value of -1 is
unlimited.

pcmk_on_action string on For advanced use only: An alternate


command to run instead of on. Some devices
do not support the standard commands or
may provide additional ones. Use this to
specify an alternate, device-specific,
command that implements the on action.

pcmk_on_timeout time 60s For advanced use only: Specify an alternate


timeout to use for on actions instead of
stonith-timeout. Some devices need much
more or much less time to complete than
normal. Use this to specify an alternate,
device-specific, timeout for on actions.

pcmk_on_retries integer 2 For advanced use only: The maximum


number of times to retry the on command
within the timeout period. Some devices do
not support multiple connections. Operations
may fail if the device is busy with another
task so Pacemaker will automatically retry
the operation, if there is time remaining. Use
this option to alter the number of times
Pacemaker retries on actions before giving
up.

8.5. TESTING A FENCE DEVICE


Fencing is a fundamental part of the Red Hat Cluster infrastructure and it is therefore important to
validate or test that fencing is working properly.

Use the following procedure to test a fence device.

1. Use ssh, telnet, HTTP, or whatever remote protocol is used to connect to the device to
manually log in and test the fence device or see what output is given. For example, if you will be
configuring fencing for an IPMI-enabled device, then try to log in remotely with ipmitool. Take
note of the options used when logging in manually because those options might be needed
when using the fencing agent.
If you are unable to log in to the fence device, verify that the device is pingable, there is nothing
such as a firewall configuration that is preventing access to the fence device, remote access is
enabled on the fencing device, and the credentials are correct.

2. Run the fence agent manually, using the fence agent script. This does not require that the
cluster services are running, so you can perform this step before the device is configured in the
cluster. This can ensure that the fence device is responding properly before proceeding.

NOTE
59
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

NOTE

The examples in this section use the fence_ipmilan fence agent script for an iLO
device. The actual fence agent you will use and the command that calls that
agent will depend on your server hardware. You should consult the man page for
the fence agent you are using to determine which options to specify. You will
usually need to know the login and password for the fence device and other
information related to the fence device.

The following example shows the format you would use to run the fence_ipmilan fence agent
script with -o status parameter to check the status of the fence device interface on another
node without actually fencing it. This allows you to test the device and get it working before
attempting to reboot the node. When running this command, you specify the name and
password of an iLO user that has power on and off permissions for the iLO device.

# fence_ipmilan -a ipaddress -l username -p password -o status

The following example shows the format you would use to run the fence_ipmilan fence agent
script with the -o reboot parameter. Running this command on one node reboots the node
managed by this iLO device.

# fence_ipmilan -a ipaddress -l username -p password -o reboot

If the fence agent failed to properly do a status, off, on, or reboot action, you should check the
hardware, the configuration of the fence device, and the syntax of your commands. In addition,
you can run the fence agent script with the debug output enabled. The debug output is useful
for some fencing agents to see where in the sequence of events the fencing agent script is
failing when logging into the fence device.

# fence_ipmilan -a ipaddress -l username -p password -o status -D /tmp/$(hostname)-


fence_agent.debug

When diagnosing a failure that has occurred, you should ensure that the options you specified
when manually logging in to the fence device are identical to what you passed on to the fence
agent with the fence agent script.

For fence agents that support an encrypted connection, you may see an error due to certificate
validation failing, requiring that you trust the host or that you use the fence agent’s ssl-
insecure parameter. Similarly, if SSL/TLS is disabled on the target device, you may need to
account for this when setting the SSL parameters for the fence agent.

NOTE

If the fence agent that is being tested is a fence_drac, fence_ilo, or some other
fencing agent for a systems management device that continues to fail, then fall
back to trying fence_ipmilan. Most systems management cards support IPMI
remote login and the only supported fencing agent is fence_ipmilan.

3. Once the fence device has been configured in the cluster with the same options that worked
manually and the cluster has been started, test fencing with the pcs stonith fence command
from any node (or even multiple times from different nodes), as in the following example. The
pcs stonith fence command reads the cluster configuration from the CIB and calls the fence
agent as configured to execute the fence action. This verifies that the cluster configuration is
correct.

60
CHAPTER 8. CONFIGURING FENCING IN A RED HAT HIGH AVAILABILITY CLUSTER

# pcs stonith fence node_name

If the pcs stonith fence command works properly, that means the fencing configuration for the
cluster should work when a fence event occurs. If the command fails, it means that cluster
management cannot invoke the fence device through the configuration it has retrieved. Check
for the following issues and update your cluster configuration as needed.

Check your fence configuration. For example, if you have used a host map you should
ensure that the system can find the node using the host name you have provided.

Check whether the password and user name for the device include any special characters
that could be misinterpreted by the bash shell. Making sure that you enter passwords and
user names surrounded by quotation marks could address this issue.

Check whether you can connect to the device using the exact IP address or host name you
specified in the pcs stonith command. For example, if you give the host name in the stonith
command but test by using the IP address, that is not a valid test.

If the protocol that your fence device uses is accessible to you, use that protocol to try to
connect to the device. For example many agents use ssh or telnet. You should try to
connect to the device with the credentials you provided when configuring the device, to see
if you get a valid prompt and can log in to the device.
If you determine that all your parameters are appropriate but you still have trouble
connecting to your fence device, you can check the logging on the fence device itself, if the
device provides that, which will show if the user has connected and what command the user
issued. You can also search through the /var/log/messages file for instances of stonith and
error, which could give some idea of what is transpiring, but some agents can provide
additional information.

4. Once the fence device tests are working and the cluster is up and running, test an actual failure.
To do this, take an action in the cluster that should initiate a token loss.

Take down a network. How you take a network depends on your specific configuration. In
many cases, you can physically pull the network or power cables out of the host. For
information on simulating a network failure, see What is the proper way to simulate a
network failure on a RHEL Cluster?.

NOTE

Disabling the network interface on the local host rather than physically
disconnecting the network or power cables is not recommended as a test of
fencing because it does not accurately simulate a typical real-world failure.

Block corosync traffic both inbound and outbound using the local firewall.
The following example blocks corosync, assuming the default corosync port is used,
firewalld is used as the local firewall, and the network interface used by corosync is in the
default firewall zone:

# firewall-cmd --direct --add-rule ipv4 filter OUTPUT 2 -p udp --dport=5405 -j DROP


# firewall-cmd --add-rich-rule='rule family="ipv4" port port="5405" protocol="udp"
drop'

Simulate a crash and panic your machine with sysrq-trigger. Note, however, that triggering
a kernel panic can cause data loss; it is recommended that you disable your cluster
resources first.

61
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

# echo c > /proc/sysrq-trigger

8.6. CONFIGURING FENCING LEVELS


Pacemaker supports fencing nodes with multiple devices through a feature called fencing topologies.
To implement topologies, create the individual devices as you normally would and then define one or
more fencing levels in the fencing topology section in the configuration.

Each level is attempted in ascending numeric order, starting at 1.

If a device fails, processing terminates for the current level. No further devices in that level are
exercised and the next level is attempted instead.

If all devices are successfully fenced, then that level has succeeded and no other levels are tried.

The operation is finished when a level has passed (success), or all levels have been attempted
(failed).

Use the following command to add a fencing level to a node. The devices are given as a comma-
separated list of stonith ids, which are attempted for the node at that level.

pcs stonith level add level node devices

The following command lists all of the fencing levels that are currently configured.

pcs stonith level

In the following example, there are two fence devices configured for node rh7-2: an ilo fence device
called my_ilo and an apc fence device called my_apc. These commands set up fence levels so that if
the device my_ilo fails and is unable to fence the node, then Pacemaker will attempt to use the device
my_apc. This example also shows the output of the pcs stonith level command after the levels are
configured.

# pcs stonith level add 1 rh7-2 my_ilo


# pcs stonith level add 2 rh7-2 my_apc
# pcs stonith level
Node: rh7-2
Level 1 - my_ilo
Level 2 - my_apc

The following command removes the fence level for the specified node and devices. If no nodes or
devices are specified then the fence level you specify is removed from all nodes.

pcs stonith level remove level [node_id] [stonith_id] ... [stonith_id]

The following command clears the fence levels on the specified node or stonith id. If you do not specify
a node or stonith id, all fence levels are cleared.

pcs stonith level clear [node|stonith_id(s)]

If you specify more than one stonith id, they must be separated by a comma and no spaces, as in the
following example.

62
CHAPTER 8. CONFIGURING FENCING IN A RED HAT HIGH AVAILABILITY CLUSTER

# pcs stonith level clear dev_a,dev_b

The following command verifies that all fence devices and nodes specified in fence levels exist.

pcs stonith level verify

You can specify nodes in fencing topology by a regular expression applied on a node name and by a
node attribute and its value. For example, the following commands configure nodes node1, node2, and
`node3 to use fence devices apc1 and `apc2, and nodes `node4, node5, and `node6 to use fence
devices apc3 and `apc4.

pcs stonith level add 1 "regexp%node[1-3]" apc1,apc2


pcs stonith level add 1 "regexp%node[4-6]" apc3,apc4

The following commands yield the same results by using node attribute matching.

pcs node attribute node1 rack=1


pcs node attribute node2 rack=1
pcs node attribute node3 rack=1
pcs node attribute node4 rack=2
pcs node attribute node5 rack=2
pcs node attribute node6 rack=2
pcs stonith level add 1 attrib%rack=1 apc1,apc2
pcs stonith level add 1 attrib%rack=2 apc3,apc4

8.7. CONFIGURING FENCING FOR REDUNDANT POWER SUPPLIES


When configuring fencing for redundant power supplies, the cluster must ensure that when attempting
to reboot a host, both power supplies are turned off before either power supply is turned back on.

If the node never completely loses power, the node may not release its resources. This opens up the
possibility of nodes accessing these resources simultaneously and corrupting them.

You need to define each device only once and to specify that both are required to fence the node, as in
the following example.

# pcs stonith create apc1 fence_apc_snmp ipaddr=apc1.example.com login=user


passwd='7a4D#1j!pz864' pcmk_host_map="node1.example.com:1;node2.example.com:2"

# pcs stonith create apc2 fence_apc_snmp ipaddr=apc2.example.com login=user


passwd='7a4D#1j!pz864' pcmk_host_map="node1.example.com:1;node2.example.com:2"

# pcs stonith level add 1 node1.example.com apc1,apc2


# pcs stonith level add 1 node2.example.com apc1,apc2

8.8. DISPLAYING CONFIGURED FENCE DEVICES


The following command shows all currently configured fence devices. If a stonith_id is specified, the
command shows the options for that configured stonith device only. If the --full option is specified, all
configured stonith options are displayed.

pcs stonith config [stonith_id] [--full]

63
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

8.9. MODIFYING AND DELETING FENCE DEVICES


Use the following command to modify or add options to a currently configured fencing device.

pcs stonith update stonith_id [stonith_device_options]

Use the following command to remove a fencing device from the current configuration.

pcs stonith delete stonith_id

8.10. MANUALLY FENCING A CLUSTER NODE


You can fence a node manually with the following command. If you specify --off this will use the off API
call to stonith which will turn the node off instead of rebooting it.

pcs stonith fence node [--off]

In a situation where no stonith device is able to fence a node even if it is no longer active, the cluster
may not be able to recover the resources on the node. If this occurs, after manually ensuring that the
node is powered down you can enter the following command to confirm to the cluster that the node is
powered down and free its resources for recovery.


WARNING

If the node you specify is not actually off, but running the cluster software or
services normally controlled by the cluster, data corruption/cluster failure will occur.

pcs stonith confirm node

8.11. DISABLING A FENCE DEVICE


To disable a fencing device/resource, you run the pcs stonith disable command.

The following command disables the fence device myapc.

# pcs stonith disable myapc

8.12. PREVENTING A NODE FROM USING A FENCE DEVICE


To prevent a specific node from using a fencing device, you can configure location constraints for the
fencing resource.

The following example prevents fence device node1-ipmi from running on node1.

# pcs constraint location node1-ipmi avoids node1

64
CHAPTER 8. CONFIGURING FENCING IN A RED HAT HIGH AVAILABILITY CLUSTER

8.13. CONFIGURING ACPI FOR USE WITH INTEGRATED FENCE


DEVICES
If your cluster uses integrated fence devices, you must configure ACPI (Advanced Configuration and
Power Interface) to ensure immediate and complete fencing.

If a cluster node is configured to be fenced by an integrated fence device, disable ACPI Soft-Off for
that node. Disabling ACPI Soft-Off allows an integrated fence device to turn off a node immediately and
completely rather than attempting a clean shutdown (for example, shutdown -h now). Otherwise, if
ACPI Soft-Off is enabled, an integrated fence device can take four or more seconds to turn off a node
(see the note that follows). In addition, if ACPI Soft-Off is enabled and a node panics or freezes during
shutdown, an integrated fence device may not be able to turn off the node. Under those circumstances,
fencing is delayed or unsuccessful. Consequently, when a node is fenced with an integrated fence
device and ACPI Soft-Off is enabled, a cluster recovers slowly or requires administrative intervention to
recover.

NOTE

The amount of time required to fence a node depends on the integrated fence device
used. Some integrated fence devices perform the equivalent of pressing and holding the
power button; therefore, the fence device turns off the node in four to five seconds.
Other integrated fence devices perform the equivalent of pressing the power button
momentarily, relying on the operating system to turn off the node; therefore, the fence
device turns off the node in a time span much longer than four to five seconds.

The preferred way to disable ACPI Soft-Off is to change the BIOS setting to "instant-off" or an
equivalent setting that turns off the node without delay, as described in Section 8.13.1,
“Disabling ACPI Soft-Off with the BIOS”.

Disabling ACPI Soft-Off with the BIOS may not be possible with some systems. If disabling ACPI Soft-
Off with the BIOS is not satisfactory for your cluster, you can disable ACPI Soft-Off with one of the
following alternate methods:

Setting HandlePowerKey=ignore in the /etc/systemd/logind.conf file and verifying that the


node node turns off immediately when fenced, as described in Section 8.13.2, “Disabling ACPI
Soft-Off in the logind.conf file”. This is the first alternate method of disabling ACPI Soft-Off.

Appending acpi=off to the kernel boot command line, as described in Section 8.13.3, “Disabling
ACPI completely in the GRUB 2 File”. This is the second alternate method of disabling ACPI
Soft-Off, if the preferred or the first alternate method is not available.

IMPORTANT

This method completely disables ACPI; some computers do not boot correctly if
ACPI is completely disabled. Use this method only if the other methods are not
effective for your cluster.

8.13.1. Disabling ACPI Soft-Off with the BIOS


You can disable ACPI Soft-Off by configuring the BIOS of each cluster node with the following
procedure.

NOTE
65
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

NOTE

The procedure for disabling ACPI Soft-Off with the BIOS may differ among server
systems. You should verify this procedure with your hardware documentation.

1. Reboot the node and start the BIOS CMOS Setup Utility program.

2. Navigate to the Power menu (or equivalent power management menu).

3. At the Power menu, set the Soft-Off by PWR-BTTN function (or equivalent) to Instant-Off (or
the equivalent setting that turns off the node by means of the power button without delay).
BIOS CMOS Setup Utility: shows a Power menu with ACPI Function set to Enabled and Soft-
Off by PWR-BTTN set to Instant-Off.

NOTE

The equivalents to ACPI Function, Soft-Off by PWR-BTTN, and Instant-Off may


vary among computers. However, the objective of this procedure is to configure
the BIOS so that the computer is turned off by means of the power button
without delay.

4. Exit the BIOS CMOS Setup Utility program, saving the BIOS configuration.

5. Verify that the node turns off immediately when fenced. For information on testing a fence
device, see Testing a fence device .

BIOS CMOS Setup Utility:

`Soft-Off by PWR-BTTN` set to


`Instant-Off`

+---------------------------------------------|-------------------+
| ACPI Function [Enabled] | Item Help |
| ACPI Suspend Type [S1(POS)] |-------------------|
| x Run VGABIOS if S3 Resume Auto | Menu Level * |
| Suspend Mode [Disabled] | |
| HDD Power Down [Disabled] | |
| Soft-Off by PWR-BTTN [Instant-Off | |
| CPU THRM-Throttling [50.0%] | |
| Wake-Up by PCI card [Enabled] | |
| Power On by Ring [Enabled] | |
| Wake Up On LAN [Enabled] | |
| x USB KB Wake-Up From S3 Disabled | |
| Resume by Alarm [Disabled] | |
| x Date(of Month) Alarm 0 | |
| x Time(hh:mm:ss) Alarm 0: 0: | |
| POWER ON Function [BUTTON ONLY | |
| x KB Power ON Password Enter | |
| x Hot Key Power ON Ctrl-F1 | |
| | |
| | |
+---------------------------------------------|-------------------+

This example shows ACPI Function set to Enabled, and Soft-Off by PWR-BTTN set to Instant-Off.

66
CHAPTER 8. CONFIGURING FENCING IN A RED HAT HIGH AVAILABILITY CLUSTER

8.13.2. Disabling ACPI Soft-Off in the logind.conf file


To disable power-key handing in the /etc/systemd/logind.conf file, use the following procedure.

1. Define the following configuration in the /etc/systemd/logind.conf file:

HandlePowerKey=ignore

2. Reload the systemd configuration:

# systemctl daemon-reload

3. Verify that the node turns off immediately when fenced. For information on testing a fence
device, see Testing a fence device .

8.13.3. Disabling ACPI completely in the GRUB 2 File


You can disable ACPI Soft-Off by appending acpi=off to the GRUB menu entry for a kernel.

IMPORTANT

This method completely disables ACPI; some computers do not boot correctly if ACPI is
completely disabled. Use this method only if the other methods are not effective for your
cluster.

Use the following procedure to disable ACPI in the GRUB 2 file:

1. Use the --args option in combination with the --update-kernel option of the grubby tool to
change the grub.cfg file of each cluster node as follows:

# grubby --args=acpi=off --update-kernel=ALL

2. Reboot the node.

3. Verify that the node turns off immediately when fenced. For information on testing a fence
device, see Testing a fence device .

67
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 9. CONFIGURING CLUSTER RESOURCES


The format for the command to create a cluster resource is as follows:

pcs resource create resource_id [standard:[provider:]]type [resource_options] [op operation_action


operation_options [operation_action operation options]...] [meta meta_options...] [clone
[clone_options] | master [master_options] | --group group_name [--before resource_id | --after
resource_id] | [bundle bundle_id] [--disabled] [--wait[=n]]

Key cluster resource creation options include the following:

When you specify the --group option, the resource is added to the resource group named. If
the group does not exist, this creates the group and adds this resource to the group.

The --before and --after options specify the position of the added resource relative to a
resource that already exists in a resource group.

Specifying the --disabled option indicates that the resource is not started automatically.

You can determine the behavior of a resource in a cluster by configuring constraints for that resource.

Resource creation examples


The following command creates a resource with the name VirtualIP of standard ocf, provider heartbeat,
and type IPaddr2. The floating address of this resource is 192.168.0.120, and the system will check
whether the resource is running every 30 seconds.

# pcs resource create VirtualIP ocf:heartbeat:IPaddr2 ip=192.168.0.120 cidr_netmask=24 op


monitor interval=30s

Alternately, you can omit the standard and provider fields and use the following command. This will
default to a standard of ocf and a provider of heartbeat.

# pcs resource create VirtualIP IPaddr2 ip=192.168.0.120 cidr_netmask=24 op monitor


interval=30s

Deleting a configured resource


Use the following command to delete a configured resource.

pcs resource delete resource_id

For example, the following command deletes an existing resource with a resource ID of VirtualIP.

# pcs resource delete VirtualIP

9.1. RESOURCE AGENT IDENTIFIERS


The identifiers that you define for a resource tell the cluster which agent to use for the resource, where
to find that agent and what standards it conforms to. Table 9.1, “Resource Agent Identifiers” , describes
these properties.

Table 9.1. Resource Agent Identifiers

68
CHAPTER 9. CONFIGURING CLUSTER RESOURCES

Field Description

standard The standard the agent conforms to. Allowed values and their meaning:

* ocf - The specified type is the name of an executable file conforming


to the Open Cluster Framework Resource Agent API and located
beneath /usr/lib/ocf/resource.d/provider

* lsb - The specified type is the name of an executable file conforming


to Linux Standard Base Init Script Actions. If the type does not specify a
full path, the system will look for it in the /etc/init.d directory.

* systemd - The specified type is the name of an installed systemd


unit

* service - Pacemaker will search for the specifiedtype, first as an lsb


agent, then as a systemd agent

* nagios - The specified type is the name of an executable file


conforming to the Nagios Plugin API and located in the
/usr/libexec/nagios/plugins directory, with OCF-style metadata
stored separately in the /usr/share/nagios/plugins-metadata
directory (available in the nagios-agents-metadata package for
certain common plugins).

type The name of the resource agent you wish to use, for example IPaddr or
Filesystem

provider The OCF spec allows multiple vendors to supply the same resource
agent. Most of the agents shipped by Red Hat use heartbeat as the
provider.

Table 9.2, “Commands to Display Resource Properties” summarizes the commands that display the
available resource properties.

Table 9.2. Commands to Display Resource Properties

pcs Display Command Output

pcs resource list Displays a list of all available resources.

pcs resource standards Displays a list of available resource agent standards.

pcs resource providers Displays a list of available resource agent providers.

pcs resource list string Displays a list of available resources filtered by the
specified string. You can use this command to display
resources filtered by the name of a standard, a
provider, or a type.

9.2. DISPLAYING RESOURCE-SPECIFIC PARAMETERS

69
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

For any individual resource, you can use the following command to display a description of the resource,
the parameters you can set for that resource, and the default values that are set for the resource.

pcs resource describe [standard:[provider:]]type

For example, the following command displays information for a resource of type apache.

# pcs resource describe ocf:heartbeat:apache


This is the resource agent for the Apache Web server.
This resource agent operates both version 1.x and version 2.x Apache
servers.

...

9.3. CONFIGURING RESOURCE META OPTIONS


In addition to the resource-specific parameters, you can configure additional resource options for any
resource. These options are used by the cluster to decide how your resource should behave.

Table 9.3, “Resource Meta Options” describes the resource meta options.

Table 9.3. Resource Meta Options

Field Default Description

priority 0 If not all resources can be active, the


cluster will stop lower priority resources
in order to keep higher priority ones
active.

target-role Started What state should the cluster attempt


to keep this resource in? Allowed
values:

* Stopped - Force the resource to be


stopped

* Started - Allow the resource to be


started (and in the case of promotable
clones, promoted to master role if
appropriate)

* Master - Allow the resource to be


started and, if appropriate, promoted

* Slave - Allow the resource to be


started, but only in Slave mode if the
resource is promotable

is-managed true Is the cluster allowed to start and stop


the resource? Allowed values: true,
false

70
CHAPTER 9. CONFIGURING CLUSTER RESOURCES

Field Default Description

resource-stickiness 0 Value to indicate how much the


resource prefers to stay where it is.

requires Calculated Indicates under what conditions the


resource can be started.

Defaults to fencing except under the


conditions noted below. Possible
values:

* nothing - The cluster can always


start the resource.

* quorum - The cluster can only start


this resource if a majority of the
configured nodes are active. This is the
default value if stonith-enabled is
false or the resource’s standard is
stonith .

* fencing - The cluster can only start


this resource if a majority of the
configured nodes are active and any
failed or unknown nodes have been
fenced.

* unfencing - The cluster can only


start this resource if a majority of the
configured nodes are active and any
failed or unknown nodes have been
fenced and only on nodes that have
been unfenced. This is the default value
if the provides=unfencing stonith
meta option has been set for a fencing
device.

migration-threshold INFINITY How many failures may occur for this


resource on a node, before this node is
marked ineligible to host this resource.
A value of 0 indicates that this feature
is disabled (the node will never be
marked ineligible); by contrast, the
cluster treats INFINITY (the default)
as a very large but finite number. This
option has an effect only if the failed
operation has on-fail=restart (the
default), and additionally for failed
start operations if the cluster property
start-failure-is-fatal is false.

71
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Field Default Description

failure-timeout 0 (disabled) Used in conjunction with the


migration-threshold option,
indicates how many seconds to wait
before acting as if the failure had not
occurred, and potentially allowing the
resource back to the node on which it
failed.

multiple-active stop_start What should the cluster do if it ever


finds the resource active on more than
one node. Allowed values:

* block - mark the resource as


unmanaged

* stop_only - stop all active instances


and leave them that way

* stop_start - stop all active instances


and start the resource in one location
only

9.3.1. Changing the default value of a resource option


To change the default value of a resource option, use the following command.

pcs resource defaults options

For example, the following command resets the default value of resource-stickiness to 100.

# pcs resource defaults resource-stickiness=100

9.3.2. Displaying currently configured resource defaults


Omitting the options parameter from the pcs resource defaults displays a list of currently configured
default values for resource options. The following example shows the output of this command after you
have reset the default value of resource-stickiness to 100.

# pcs resource defaults


resource-stickiness: 100

9.3.3. Setting meta options on resource creation


Whether you have reset the default value of a resource meta option or not, you can set a resource
option for a particular resource to a value other than the default when you create the resource. The
following shows the format of the pcs resource create command you use when specifying a value for a
resource meta option.

pcs resource create resource_id [standard:[provider:]]type [resource options] [meta meta_options...]

72
CHAPTER 9. CONFIGURING CLUSTER RESOURCES

For example, the following command creates a resource with a resource-stickiness value of 50.

# pcs resource create VirtualIP ocf:heartbeat:IPaddr2 ip=192.168.0.120 meta resource-


stickiness=50

You can also set the value of a resource meta option for an existing resource, group, cloned resource, or
master resource with the following command.

pcs resource meta resource_id | group_id | clone_id meta_options

In the following example, there is an existing resource named dummy_resource. This command sets the
failure-timeout meta option to 20 seconds, so that the resource can attempt to restart on the same
node in 20 seconds.

# pcs resource meta dummy_resource failure-timeout=20s

After executing this command, you can display the values for the resource to verify that failure-
timeout=20s is set.

# pcs resource config dummy_resource


Resource: dummy_resource (class=ocf provider=heartbeat type=Dummy)
Meta Attrs: failure-timeout=20s
...

9.4. CONFIGURING RESOURCE GROUPS


One of the most common elements of a cluster is a set of resources that need to be located together,
start sequentially, and stop in the reverse order. To simplify this configuration, Pacemaker supports the
concept of resource groups.

9.4.1. Creating a resource group


You create a resource group with the following command, specifying the resources to include in the
group. If the group does not exist, this command creates the group. If the group exists, this command
adds additional resources to the group. The resources will start in the order you specify them with this
command, and will stop in the reverse order of their starting order.

pcs resource group add group_name resource_id [resource_id] ... [resource_id] [--before resource_id
| --after resource_id]

You can use the --before and --after options of this command to specify the position of the added
resources relative to a resource that already exists in the group.

You can also add a new resource to an existing group when you create the resource, using the following
command. The resource you create is added to the group named group_name. If the group group_name
does not exist, it will be created.

pcs resource create resource_id [standard:[provider:]]type [resource_options] [op operation_action


operation_options] --group group_name

There is no limit to the number of resources a group can contain. The fundamental properties of a group
are as follows.

73
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Resources are colocated within a group.

Resources are started in the order in which you specify them. If a resource in the group cannot
run anywhere, then no resource specified after that resource is allowed to run.

Resources are stopped in the reverse order in which you specify them.

The following example creates a resource group named shortcut that contains the existing resources
IPaddr and Email.

# pcs resource group add shortcut IPaddr Email

In this example:

The IPaddr is started first, then Email.

The Email resource is stopped first, then IPAddr.

If IPaddr cannot run anywhere, neither can Email.

If Email cannot run anywhere, however, this does not affect IPaddr in any way.

9.4.2. Removing a resource group


You remove a resource from a group with the following command. If there are no remaining resources in
the group, this command removes the group itself.

pcs resource group remove group_name resource_id...

9.4.3. Displaying resource groups


The following command lists all currently configured resource groups.

pcs resource group list

9.4.4. Group options


You can set the following options for a resource group, and they maintain the same meaning as when
they are set for a single resource: priority, target-role, is-managed. For information on resource meta
options, see Configuring resource meta options.

9.4.5. Group stickiness


Stickiness, the measure of how much a resource wants to stay where it is, is additive in groups. Every
active resource of the group will contribute its stickiness value to the group’s total. So if the default
resource-stickiness is 100, and a group has seven members, five of which are active, then the group as
a whole will prefer its current location with a score of 500.

9.5. DETERMINING RESOURCE BEHAVIOR


You can determine the behavior of a resource in a cluster by configuring constraints for that resource.
You can configure the following categories of constraints:

location constraints — A location constraint determines which nodes a resource can run on. For
74
CHAPTER 9. CONFIGURING CLUSTER RESOURCES

location constraints — A location constraint determines which nodes a resource can run on. For
information on configuring location constraints, see Determining which nodes a resource can
run on.

order constraints — An ordering constraint determines the order in which the resources run. For
information on configuring ordering constraints, see Determining the order in which cluster
resources are run.

colocation constraints — A colocation constraint determines where resources will be placed


relative to other resources. For information on colocation constraints, see Colocating cluster
resources.

As a shorthand for configuring a set of constraints that will locate a set of resources together and
ensure that the resources start sequentially and stop in reverse order, Pacemaker supports the concept
of resource groups. After you have created a resource group, you can configure constraints on the
group itself just as you configure constraints for individual resources. For information on resource
groups, see Configuring resource groups.

75
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 10. DETERMINING WHICH NODES A RESOURCE


CAN RUN ON
Location constraints determine which nodes a resource can run on. You can configure location
constraints to determine whether a resource will prefer or avoid a specified node.

10.1. CONFIGURING LOCATION CONSTRAINTS


You can configure a basic location constraint to specify whether a resource prefers or avoids a node,
with an optional score value to indicate the relative degree of preference for the constraint.

The following command creates a location constraint for a resource to prefer the specified node or
nodes. Note that it is possible to create constraints on a particular resource for more than one node with
a single command.

pcs constraint location rsc prefers node[=score] [node[=score]] ...

The following command creates a location constraint for a resource to avoid the specified node or
nodes.

pcs constraint location rsc avoids node[=score] [node[=score]] ...

Table 10.1, “Location Constraint Options” summarizes the meanings of the basic options for configuring
location constraints.

Table 10.1. Location Constraint Options

Field Description

rsc A resource name

node A node’s name

score Positive integer value to indicate the degree of preference for whether
the given resource should prefer or avoid the given node. INFINITY is
the default score value for a resource location constraint.

A value of INFINITY for score in a command that configures a resource


to prefer a node indicates that the resource will prefer that node if the
node is available, but does not prevent the resource from running on
another node if the specified node is unavailable. A value of INFINITY in
a command that configures a resource to avoid a node indicates that the
resource will never run on that node, even if no other node is available.

A numeric score (that is, not INFINITY) means the constraint is optional,
and will be honored unless some other factor outweighs it. For example,
if the resource is already placed on a different node, and its resource-
stickiness score is higher than aprefers location constraint’s score,
then the resource will be left where it is.

The following command creates a location constraint to specify that the resource Webserver prefers
node node1.

76
CHAPTER 10. DETERMINING WHICH NODES A RESOURCE CAN RUN ON

pcs constraint location Webserver prefers node1

pcs supports regular expressions in location constraints on the command line. These constraints apply
to multiple resources based on the regular expression matching resource name. This allows you to
configure multiple location contraints with a single command line.

The following command creates a location constraint to specify that resources dummy0 to dummy9
prefer node1.

pcs constraint location 'regexp%dummy[0-9]' prefers node1

Since Pacemaker uses POSIX extended regular expressions as documented at


http://pubs.opengroup.org/onlinepubs/9699919799/basedefs/V1_chap09.html#tag_09_04, you can
specify the same constraint with the following command.

pcs constraint location 'regexp%dummy[[:digit:]]' prefers node1

10.2. LIMITING RESOURCE DISCOVERY TO A SUBSET OF NODES


Before Pacemaker starts a resource anywhere, it first runs a one-time monitor operation (often referred
to as a "probe") on every node, to learn whether the resource is already running. This process of
resource discovery can result in errors on nodes that are unable to execute the monitor.

When configuring a location constraint on a node, you can use the resource-discovery option of the
pcs constraint location command to indicate a preference for whether Pacemaker should perform
resource discovery on this node for the specified resource. Limiting resource discovery to a subset of
nodes the resource is physically capable of running on can significantly boost performance when a large
set of nodes is present. When pacemaker_remote is in use to expand the node count into the hundreds
of nodes range, this option should be considered.

The following command shows the format for specifying the resource-discovery option of the pcs
constraint location command. In this command, a positive value for score corresponds to a basic
location constraint that configures a resource to prefer a node, while a negative value for score
corresponds to a basic location`constraint that configures a resource to avoid a node. As with basic
location constraints, you can use regular expressions for resources with these constraints as well.

pcs constraint location add id rsc node score [resource-discovery=option]

Table 10.2, “Resource Discovery Constraint Parameters” summarizes the meanings of the basic
parameters for configuring constraints for resource discovery.

Table 10.2. Resource Discovery Constraint Parameters

Field Description

id A user-chosen name for the constraint itself.

rsc A resource name

node A node’s name

77
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

score Integer value to indicate the degree of preference for whether


the given resource should prefer or avoid the given node. A
positive value for score corresponds to a basic location
constraint that configures a resource to prefer a node, while a
negative value for score corresponds to a basic location
constraint that configures a resource to avoid a node.

A value of INFINITY for score indicates that the resource will


prefer that node if the node is available, but does not prevent
the resource from running on another node if the specified node
is unavailable. A value of -INFINITY in a command that
configures a resource to avoid a node indicates that the
resource will never run on that node, even if no other node is
available.

A numeric score (that is, not INFINITY or -INFINITY) means


the constraint is optional, and will be honored unless some other
factor outweighs it. For example, if the resource is already
placed on a different node, and its resource-stickiness score
is higher than a prefers location constraint’s score, then the
resource will be left where it is.

resource-discovery options * always - Always perform resource discovery for the specified
resource on this node. This is the default resource-discovery
value for a resource location constraint.

* never - Never perform resource discovery for the specified


resource on this node.

* exclusive - Perform resource discovery for the specified


resource only on this node (and other nodes similarly marked as
exclusive). Multiple location constraints using exclusive
discovery for the same resource across different nodes creates
a subset of nodes resource-discovery is exclusive to. If a
resource is marked for exclusive discovery on one or more
nodes, that resource is only allowed to be placed within that
subset of nodes.


WARNING

Setting resource-discovery to never or exclusive removes Pacemaker’s ability to


detect and stop unwanted instances of a service running where it is not supposed to
be. It is up to the system administrator to make sure that the service can never be
active on nodes without resource discovery (such as by leaving the relevant
software uninstalled).

10.3. CONFIGURING A LOCATION CONSTRAINT STRATEGY

78
CHAPTER 10. DETERMINING WHICH NODES A RESOURCE CAN RUN ON

When using location constraints, you can configure a general strategy for specifying which nodes a
resource can run on:

Opt-In Clusters — Configure a cluster in which, by default, no resource can run anywhere and
then selectively enable allowed nodes for specific resources.

Opt-Out Clusters — Configure a cluster in which, by default, all resources can run anywhere and
then create location constraints for resources that are not allowed to run on specific nodes.

Whether you should choose to configure your cluster as an opt-in or opt-out cluster depends on both
your personal preference and the make-up of your cluster. If most of your resources can run on most of
the nodes, then an opt-out arrangement is likely to result in a simpler configuration. On the other hand,
if most resources can only run on a small subset of nodes an opt-in configuration might be simpler.

10.3.1. Configuring an "Opt-In" Cluster


To create an opt-in cluster, set the symmetric-cluster cluster property to false to prevent resources
from running anywhere by default.

# pcs property set symmetric-cluster=false

Enable nodes for individual resources. The following commands configure location constraints so that
the resource Webserver prefers node example-1, the resource Database prefers node example-2, and
both resources can fail over to node example-3 if their preferred node fails. When configuring location
constraints for an opt-in cluster, setting a score of zero allows a resource to run on a node without
indicating any preference to prefer or avoid the node.

# pcs constraint location Webserver prefers example-1=200


# pcs constraint location Webserver prefers example-3=0
# pcs constraint location Database prefers example-2=200
# pcs constraint location Database prefers example-3=0

10.3.2. Configuring an "Opt-Out" Cluster


To create an opt-out cluster, set the symmetric-cluster cluster property to true to allow resources to
run everywhere by default. This is the default configuration if symmetric-cluster is not set explicitly.

# pcs property set symmetric-cluster=true

The following commands will then yield a configuration that is equivalent to the example in
Section 10.3.1, “Configuring an "Opt-In" Cluster” . Both resources can fail over to node example-3 if their
preferred node fails, since every node has an implicit score of 0.

# pcs constraint location Webserver prefers example-1=200


# pcs constraint location Webserver avoids example-2=INFINITY
# pcs constraint location Database avoids example-1=INFINITY
# pcs constraint location Database prefers example-2=200

Note that it is not necessary to specify a score of INFINITY in these commands, since that is the default
value for the score.

79
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 11. DETERMINING THE ORDER IN WHICH CLUSTER


RESOURCES ARE RUN
To determine the order in which the resources run, you configure an ordering constraint.

The following shows the format for the command to configure an ordering constraint.

pcs constraint order [action] resource_id then [action] resource_id [options]

Table 11.1, “Properties of an Order Constraint” , summarizes the properties and options for configuring
ordering constraints.

Table 11.1. Properties of an Order Constraint

Field Description

resource_id The name of a resource on which an action is performed.

action The action to perform on a resource. Possible values of the


action property are as follows:

* start - Start the resource.

* stop - Stop the resource.

* promote - Promote the resource from a slave resource to a


master resource.

* demote - Demote the resource from a master resource to a


slave resource.

If no action is specified, the default action is start.

kind option How to enforce the constraint. The possible values of the kind
option are as follows:

* Optional - Only applies if both resources are executing the


specified action. For information on optional ordering, see
Configuring advisory ordering.

* Mandatory - Always (default value). If the first resource you


specified is stopping or cannot be started, the second resource
you specified must be stopped. For information on mandatory
ordering, see Configuring mandatory ordering.

* Serialize - Ensure that no two stop/start actions occur


concurrently for the resources you specify. The first and second
resource you specify can start in either order, but one must
complete starting before the other can be started. A typical use
case is when resource startup puts a high load on the host.

80
CHAPTER 11. DETERMINING THE ORDER IN WHICH CLUSTER RESOURCES ARE RUN

Field Description

symmetrical option If true, the reverse of the constraint applies for the opposite
action (for example, if B starts after A starts, then B stops
before Ordering constraints for which kind is Serialize cannot
be symmetrical. The default value is true for Mandatory and
Ordering kinds, false for Serialize .

Use the following command to remove resources from any ordering constraint.

pcs constraint order remove resource1 [resourceN]...

11.1. CONFIGURING MANDATORY ORDERING


A mandatory ordering constraint indicates that the second action should not be initiated for the second
resource unless and until the first action successfully completes for the first resource. Actions that may
be ordered are stop, start, and additionally for promotable clones, demote and promote. For example,
"A then B" (which is equivalent to "start A then start B") means that B will not be started unless and until
A successfully starts. An ordering constraint is mandatory if the kind option for the constraint is set to
Mandatory or left as default.

If the symmetrical option is set to true or left to default, the opposite actions will be ordered in reverse.
The start and stop actions are opposites, and demote and promote are opposites. For example, a
symmetrical "promote A then start B" ordering implies "stop B then demote A", which means that A
cannot be demoted until and unless B successfully stops. A symmetrical ordering means that changes in
A’s state can cause actions to be scheduled for B. For example, given "A then B", if A restarts due to
failure, B will be stopped first, then A will be stopped, then A will be started, then B will be started.

Note that the cluster reacts to each state change. If the first resource is restarted and is in a started
state again before the second resource initiated a stop operation, the second resource will not need to
be restarted.

11.2. CONFIGURING ADVISORY ORDERING


When the kind=Optional option is specified for an ordering constraint, the constraint is considered
optional and only applies if both resources are executing the specified actions. Any change in state by
the first resource you specify will have no effect on the second resource you specify.

The following command configures an advisory ordering constraint for the resources named VirtualIP
and dummy_resource.

# pcs constraint order VirtualIP then dummy_resource kind=Optional

11.3. CONFIGURING ORDERED RESOURCE SETS


A common situation is for an administrator to create a chain of ordered resources, where, for example,
resource A starts before resource B which starts before resource C. If your configuration requires that
you create a set of resources that is colocated and started in order, you can configure a resource group
that contains those resources, as described in Configuring resource groups.

There are some situations, however, where configuring the resources that need to start in a specified
81
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

There are some situations, however, where configuring the resources that need to start in a specified
order as a resource group is not appropriate:

You may need to configure resources to start in order and the resources are not necessarily
colocated.

You may have a resource C that must start after either resource A or B has started but there is
no relationship between A and B.

You may have resources C and D that must start after both resources A and B have started, but
there is no relationship between A and B or between C and D.

In these situations, you can create an ordering constraint on a set or sets of resources with the pcs
constraint order set command.

You can set the following options for a set of resources with the pcs constraint order set command.

sequential, which can be set to true or false to indicate whether the set of resources must be
ordered relative to each other. The default value is true.
Setting sequential to false allows a set to be ordered relative to other sets in the ordering
constraint, without its members being ordered relative to each other. Therefore, this option
makes sense only if multiple sets are listed in the constraint; otherwise, the constraint has no
effect.

require-all, which can be set to true or false to indicate whether all of the resources in the set
must be active before continuing. Setting require-all to false means that only one resource in
the set needs to be started before continuing on to the next set. Setting require-all to false has
no effect unless used in conjunction with unordered sets, which are sets for which sequential is
set to false. The default value is true.

action, which can be set to start, promote, demote or stop, as described in Properties of an
Order Constraint.

role, which can be set to Stopped, Started, Master, or Slave.

You can set the following constraint options for a set of resources following the setoptions parameter
of the pcs constraint order set command.

id, to provide a name for the constraint you are defining.

kind, which indicates how to enforce the constraint, as described in Properties of an Order
Constraint.

symmetrical, to set whether the reverse of the constraint applies for the opposite action, as
described in Properties of an Order Constraint .

pcs constraint order set resource1 resource2 [resourceN]... [options] [set resourceX resourceY ...
[options]] [setoptions [constraint_options]]

If you have three resources named D1, D2, and D3, the following command configures them as an
ordered resource set.

# pcs constraint order set D1 D2 D3

If you have six resources named A, B, C, D, E, and F, this example configures an ordering constraint for
the set of resources that will start as follows:

82
CHAPTER 11. DETERMINING THE ORDER IN WHICH CLUSTER RESOURCES ARE RUN

A and B start independently of each other

C starts once either A or B has started

D starts once C has started

E and F start independently of each other once D has started

Stopping the resources is not influenced by this constraint since symmetrical=false is set.

# pcs constraint order set A B sequential=false require-all=false set C D set E F


sequential=false setoptions symmetrical=false

83
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 12. COLOCATING CLUSTER RESOURCES


To specify that the location of one resource depends on the location of another resource, you configure
a colocation constraint.

There is an important side effect of creating a colocation constraint between two resources: it affects
the order in which resources are assigned to a node. This is because you cannot place resource A
relative to resource B unless you know where resource B is. So when you are creating colocation
constraints, it is important to consider whether you should colocate resource A with resource B or
resource B with resource A.

Another thing to keep in mind when creating colocation constraints is that, assuming resource A is
colocated with resource B, the cluster will also take into account resource A’s preferences when
deciding which node to choose for resource B.

The following command creates a colocation constraint.

pcs constraint colocation add [master|slave] source_resource with [master|slave] target_resource


[score] [options]

Table 12.1, “Properties of a Colocation Constraint” , summarizes the properties and options for
configuring colocation constraints.

Table 12.1. Properties of a Colocation Constraint

Field Description

source_resource The colocation source. If the constraint cannot be satisfied, the


cluster may decide not to allow the resource to run at all.

target_resource The colocation target. The cluster will decide where to put this
resource first and then decide where to put the source resource.

score Positive values indicate the resource should run on the same
node. Negative values indicate the resources should not run on
the same node. A value of +INFINITY, the default value,
indicates that the source_resource must run on the same node
as the target_resource. A value of -INFINITY indicates that the
source_resource must not run on the same node as the
target_resource.

12.1. SPECIFYING MANDATORY PLACEMENT OF RESOURCES


Mandatory placement occurs any time the constraint’s score is +INFINITY or -INFINITY. In such cases, if
the constraint cannot be satisfied, then the source_resource is not permitted to run. For
score=INFINITY, this includes cases where the target_resource is not active.

If you need myresource1 to always run on the same machine as myresource2, you would add the
following constraint:

# pcs constraint colocation add myresource1 with myresource2 score=INFINITY

Because INFINITY was used, if myresource2 cannot run on any of the cluster nodes (for whatever

84
CHAPTER 12. COLOCATING CLUSTER RESOURCES

Because INFINITY was used, if myresource2 cannot run on any of the cluster nodes (for whatever
reason) then myresource1 will not be allowed to run.

Alternatively, you may want to configure the opposite, a cluster in which myresource1 cannot run on the
same machine as myresource2. In this case use score=-INFINITY

# pcs constraint colocation add myresource1 with myresource2 score=-INFINITY

Again, by specifying -INFINITY, the constraint is binding. So if the only place left to run is where
myresource2 already is, then myresource1 may not run anywhere.

12.2. SPECIFYING ADVISORY PLACEMENT OF RESOURCES


If mandatory placement is about "must" and "must not", then advisory placement is the "I would prefer
if" alternative. For constraints with scores greater than -INFINITY and less than INFINITY, the cluster will
try to accommodate your wishes but may ignore them if the alternative is to stop some of the cluster
resources.

12.3. COLOCATING SETS OF RESOURCES


If your configuration requires that you create a set of resources that are colocated and started in order,
you can configure a resource group that contains those resources, as described in Configuring resource
groups. There are some situations, however, where configuring the resources that need to be colocated
as a resource group is not appropriate:

You may need to colocate a set of resources but the resources do not necessarily need to start
in order.

You may have a resource C that must be colocated with either resource A or B, but there is no
relationship between A and B.

You may have resources C and D that must be colocated with both resources A and B, but
there is no relationship between A and B or between C and D.

In these situations, you can create a colocation constraint on a set or sets of resources with the pcs
constraint colocation set command.

You can set the following options for a set of resources with the pcs constraint colocation set
command.

sequential, which can be set to true or false to indicate whether the members of the set must
be colocated with each other.
Setting sequential to false allows the members of this set to be colocated with another set
listed later in the constraint, regardless of which members of this set are active. Therefore, this
option makes sense only if another set is listed after this one in the constraint; otherwise, the
constraint has no effect.

role, which can be set to Stopped, Started, Master, or Slave.

You can set the following constraint option for a set of resources following the setoptions parameter of
the pcs constraint colocation set command.

id, to provide a name for the constraint you are defining.

score, to indicate the degree of preference for this constraint. For information on this option,
85
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

score, to indicate the degree of preference for this constraint. For information on this option,
see Location Constraint Options.

When listing members of a set, each member is colocated with the one before it. For example, "set A B"
means "B is colocated with A". However, when listing multiple sets, each set is colocated with the one
after it. For example, "set C D sequential=false set A B" means "set C D (where C and D have no
relation between each other) is colocated with set A B (where B is colocated with A)".

The following command creates a colocation constraint on a set or sets of resources.

pcs constraint colocation set resource1 resource2 [resourceN]... [options] [set resourceX resourceY
... [options]] [setoptions [constraint_options]]

12.4. REMOVING COLOCATION CONSTRAINTS


Use the following command to remove colocation constraints with source_resource.

pcs constraint colocation remove source_resource target_resource

86
CHAPTER 13. DISPLAYING RESOURCE CONSTRAINTS

CHAPTER 13. DISPLAYING RESOURCE CONSTRAINTS


There are a several commands you can use to display constraints that have been configured.

13.1. DISPLAYING ALL CONFIGURED CONSTRAINTS


The following command lists all current location, order, and colocation constraints.

pcs constraint list|show

13.2. DISPLAYING LOCATION CONSTRAINTS


The following command lists all current location constraints.

If resources is specified, location constraints are displayed per resource. This is the default
behavior.

If nodes is specified, location constraints are displayed per node.

If specific resources or nodes are specified, then only information about those resources or
nodes is displayed.

pcs constraint location [show [resources [resource...]] | [nodes [node...]]] [--full]

13.3. DISPLAYING ORDERING CONSTRAINTS


The following command lists all current ordering constraints. If the --full option is specified, show the
internal constraint IDs.

pcs constraint order show [--full]

13.4. DISPLAYING COLOCATION CONSTRAINTS


The following command lists all current colocation constraints. If the --full option is specified, show the
internal constraint IDs.

pcs constraint colocation show [--full]

13.5. DISPLAYING RESOURCE-SPECIFIC CONSTRAINTS


The following command lists the constraints that reference specific resources.

pcs constraint ref resource ...

87
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 14. DETERMINING RESOURCE LOCATION WITH


RULES
For more complicated location constraints, you can use Pacemaker rules to determine a resource’s
location.

14.1. PACEMAKER RULES


Rules can be used to make your configuration more dynamic. One use of rules might be to assign
machines to different processing groups (using a node attribute) based on time and to then use that
attribute when creating location constraints.

Each rule can contain a number of expressions, date-expressions and even other rules. The results of the
expressions are combined based on the rule’s boolean-op field to determine if the rule ultimately
evaluates to true or false. What happens next depends on the context in which the rule is being used.

Table 14.1. Properties of a Rule

Field Description

role Limits the rule to apply only when the resource is in


that role. Allowed values: Started, Slave, and
Master. NOTE: A rule with role="Master" cannot
determine the initial location of a clone instance. It
will only affect which of the active instances will be
promoted.

score The score to apply if the rule evaluates to true.


Limited to use in rules that are part of location
constraints.

score-attribute The node attribute to look up and use as a score if


the rule evaluates to true. Limited to use in rules that
are part of location constraints.

boolean-op How to combine the result of multiple expression


objects. Allowed values: and and or. The default
value is and .

14.1.1. Node attribute expressions


Node attribute expressions are used to control a resource based on the attributes defined by a node or
nodes.

Table 14.2. Properties of an Expression

Field Description

attribute The node attribute to test

88
CHAPTER 14. DETERMINING RESOURCE LOCATION WITH RULES

Field Description

type Determines how the value(s) should be tested.


Allowed values: string , integer , version. The
default value is string .

operation The comparison to perform. Allowed values:

* lt - True if the node attribute’s value is less than


value

* gt - True if the node attribute’s value is greater than


value

* lte - True if the node attribute’s value is less than or


equal to value

* gte - True if the node attribute’s value is greater


than or equal to value

* eq - True if the node attribute’s value is equal to


value

* ne - True if the node attribute’s value is not equal


to value

* defined - True if the node has the named attribute

* not_defined - True if the node does not have the


named attribute

value User supplied value for comparison (required unless


operation is defined or not_defined)

In addition to any attributes added by the administrator, the cluster defines special, built-in node
attributes for each node that can also be used, as described in Table 14.3, “Built-in Node Attributes” .

Table 14.3. Built-in Node Attributes

Name Description

#uname Node name

#id Node ID

89
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Name Description

#kind Node type. Possible values are cluster, remote , and


container. The value of kind is remote for
Pacemaker Remote nodes created with the
ocf:pacemaker:remote resource, and container
for Pacemaker Remote guest nodes and bundle
nodes.

#is_dc true if this node is a Designated Controller (DC),


false otherwise

#cluster_name The value of the cluster-name cluster property, if


set

#site_name The value of the site-name node attribute, if set,


otherwise identical to #cluster-name

#role The role the relevant promotable clone has on this


node. Valid only within a rule for a location constraint
for a promotable clone.

14.1.2. Time/date based expressions


Date expressions are used to control a resource or cluster option based on the current date/time. They
can contain an optional date specification.

Table 14.4. Properties of a Date Expression

Field Description

start A date/time conforming to the ISO8601


specification.

end A date/time conforming to the ISO8601


specification.

operation Compares the current date/time with the start or the


end date or both the start and end date, depending
on the context. Allowed values:

* gt - True if the current date/time is after start

* lt - True if the current date/time is beforeend

* in_range - True if the current date/time is after


start and before end

* date-spec - performs a cron-like comparison to


the current date/time

90
CHAPTER 14. DETERMINING RESOURCE LOCATION WITH RULES

14.1.3. Date specifications


Date specifications are used to create cron-like expressions relating to time. Each field can contain a
single number or a single range. Instead of defaulting to zero, any field not supplied is ignored.

For example, monthdays="1" matches the first day of every month and hours="09-17" matches the
hours between 9 am and 5 pm (inclusive). However, you cannot specify weekdays="1,2" or
weekdays="1-2,5-6" since they contain multiple ranges.

Table 14.5. Properties of a Date Specification

Field Description

id A unique name for the date

hours Allowed values: 0-23

monthdays Allowed values: 0-31 (depending on month and year)

weekdays Allowed values: 1-7 (1=Monday, 7=Sunday)

yeardays Allowed values: 1-366 (depending on the year)

months Allowed values: 1-12

weeks Allowed values: 1-53 (depending on weekyear)

years Year according the Gregorian calendar

weekyears May differ from Gregorian years; for example, 2005-


001 Ordinal is also 2005-01-01 Gregorian is also
2004-W53-6 Weekly

moon Allowed values: 0-7 (0 is new, 4 is full moon).

14.2. CONFIGURING A PACEMAKER LOCATION CONSTRAINT USING


RULES
Use the following command to configure a Pacemaker constraint that uses rules. If score is omitted, it
defaults to INFINITY. If resource-discovery is omitted, it defaults to always.

For information on the resource-discovery option, see Limiting resource discovery to a subset of
nodes.

As with basic location constraints, you can use regular expressions for resources with these constraints
as well.

When using rules to configure location constraints, the value of score can be positive or negative, with a
positive value indicating "prefers" and a negative value indicating "avoids".

91
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

pcs constraint location rsc rule [resource-discovery=option] [role=master|slave] [score=score | score-


attribute=attribute] expression

The expression option can be one of the following where duration_options and date_spec_options are:
hours, monthdays, weekdays, yeardays, months, weeks, years, weekyears, moon as described in
Properties of a Date Specification .

defined|not_defined attribute

attribute lt|gt|lte|gte|eq|ne [string|integer|version] value

date gt|lt date

date in_range date to date

date in_range date to duration duration_options …​

date-spec date_spec_options

expression and|or expression

(expression)

Note that durations are an alternative way to specify an end for in_range operations by means of
calculations. For example, you can specify a duration of 19 months.

The following location constraint configures an expression that is true if now is any time in the year 2018.

# pcs constraint location Webserver rule score=INFINITY date-spec years=2018

The following command configures an expression that is true from 9 am to 5 pm, Monday through
Friday. Note that the hours value of 16 matches up to 16:59:59, as the numeric value (hour) still matches.

# pcs constraint location Webserver rule score=INFINITY date-spec hours="9-16"


weekdays="1-5"

The following command configures an expression that is true when there is a full moon on Friday the
thirteenth.

# pcs constraint location Webserver rule date-spec weekdays=5 monthdays=13 moon=4

To remove a rule, use the following command. If the rule that you are removing is the last rule in its
constraint, the constraint will be removed.

pcs constraint rule remove rule_id

92
CHAPTER 15. MANAGING CLUSTER RESOURCES

CHAPTER 15. MANAGING CLUSTER RESOURCES


This section describes various commands you can use to manage cluster resources.

15.1. DISPLAYING CONFIGURED RESOURCES


To display a list of all configured resources, use the following command.

pcs resource status

For example, if your system is configured with a resource named VirtualIP and a resource named
WebSite, the pcs resource show command yields the following output.

# pcs resource status


VirtualIP (ocf::heartbeat:IPaddr2): Started
WebSite (ocf::heartbeat:apache): Started

To display a list of all configured resources and the parameters configured for those resources, use the -
-full option of the pcs resource config command, as in the following example.

# pcs resource config


Resource: VirtualIP (type=IPaddr2 class=ocf provider=heartbeat)
Attributes: ip=192.168.0.120 cidr_netmask=24
Operations: monitor interval=30s
Resource: WebSite (type=apache class=ocf provider=heartbeat)
Attributes: statusurl=http://localhost/server-status configfile=/etc/httpd/conf/httpd.conf
Operations: monitor interval=1min

To display the configured parameters for a resource, use the following command.

pcs resource config resource_id

For example, the following command displays the currently configured parameters for resource
VirtualIP.

# pcs resource config VirtualIP


Resource: VirtualIP (type=IPaddr2 class=ocf provider=heartbeat)
Attributes: ip=192.168.0.120 cidr_netmask=24
Operations: monitor interval=30s

15.2. MODIFYING RESOURCE PARAMETERS


To modify the parameters of a configured resource, use the following command.

pcs resource update resource_id [resource_options]

The following sequence of commands show the initial values of the configured parameters for resource
VirtualIP, the command to change the value of the ip parameter, and the values following the update
command.

# pcs resource config VirtualIP


Resource: VirtualIP (type=IPaddr2 class=ocf provider=heartbeat)

93
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Attributes: ip=192.168.0.120 cidr_netmask=24


Operations: monitor interval=30s
# pcs resource update VirtualIP ip=192.169.0.120
# pcs resource config VirtualIP
Resource: VirtualIP (type=IPaddr2 class=ocf provider=heartbeat)
Attributes: ip=192.169.0.120 cidr_netmask=24
Operations: monitor interval=30s

NOTE

When you update a resource’s operation with the pcs resource update command, any
options you do not specifically call out are reset to their default values.

15.3. CLEARING FAILURE STATUS OF CLUSTER RESOURCES


If a resource has failed, a failure message appears when you display the cluster status. If you resolve that
resource, you can clear that failure status with the pcs resource cleanup command. This command
resets the resource status and failcount, telling the cluster to forget the operation history of a resource
and re-detect its current state.

The following command cleans up the resource specified by resource_id.

pcs resource cleanup resource_id

If you do not specify a resource_id, this command resets the resource status and failcountfor all
resources.

The pcs resource cleanup command probes only the resources that display as a failed action. To probe
all resources on all nodes you can enter the following command:

pcs resource refresh

By default, the pcs resource refresh command probes only the nodes where a resource’s state is
known. To probe all resources even if the state is not known, enter the following command:

pcs resource refresh --full

15.4. MOVING RESOURCES IN A CLUSTER


Pacemaker provides a variety of mechanisms for configuring a resource to move from one node to
another and to manually move a resource when needed.

You can manually move resources in a cluster with the pcs resource move and pcs resource relocate
commands, as described in Manually moving cluster resources .

In addition to these commands, you can also control the behavior of cluster resources by enabling,
disabling, and banning resources, as described in Enabling, disabling, and banning cluster resources .

You can configure a resource so that it will move to a new node after a defined number of failures, and
you can configure a cluster to move resources when external connectivity is lost.

15.4.1. Moving resources due to failure

When you create a resource, you can configure the resource so that it will move to a new node after a
94
CHAPTER 15. MANAGING CLUSTER RESOURCES

When you create a resource, you can configure the resource so that it will move to a new node after a
defined number of failures by setting the migration-threshold option for that resource. Once the
threshold has been reached, this node will no longer be allowed to run the failed resource until:

The administrator manually resets the resource’s failcount using the pcs resource cleanup
command.

The resource’s failure-timeout value is reached.

The value of migration-threshold is set to INFINITY by default. INFINITY is defined internally as a very
large but finite number. A value of 0 disables the migration-threshold feature.

NOTE

Setting a migration-threshold for a resource is not the same as configuring a resource


for migration, in which the resource moves to another location without loss of state.

The following example adds a migration threshold of 10 to the resource named dummy_resource, which
indicates that the resource will move to a new node after 10 failures.

# pcs resource meta dummy_resource migration-threshold=10

You can add a migration threshold to the defaults for the whole cluster with the following command.

# pcs resource defaults migration-threshold=10

To determine the resource’s current failure status and limits, use the pcs resource failcount show
command.

There are two exceptions to the migration threshold concept; they occur when a resource either fails to
start or fails to stop. If the cluster property start-failure-is-fatal is set to true (which is the default), start
failures cause the failcount to be set to INFINITY and thus always cause the resource to move
immediately.

Stop failures are slightly different and crucial. If a resource fails to stop and STONITH is enabled, then
the cluster will fence the node in order to be able to start the resource elsewhere. If STONITH is not
enabled, then the cluster has no way to continue and will not try to start the resource elsewhere, but will
try to stop it again after the failure timeout.

15.4.2. Moving resources due to connectivity changes


Setting up the cluster to move resources when external connectivity is lost is a two step process.

1. Add a ping resource to the cluster. The ping resource uses the system utility of the same name
to test if a list of machines (specified by DNS host name or IPv4/IPv6 address) are reachable
and uses the results to maintain a node attribute called pingd.

2. Configure a location constraint for the resource that will move the resource to a different node
when connectivity is lost.

Table 9.1, “Resource Agent Identifiers” describes the properties you can set for a ping resource.

Table 15.1. Properties of a ping resources

95
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Field Description

dampen The time to wait (dampening) for further changes to


occur. This prevents a resource from bouncing
around the cluster when cluster nodes notice the loss
of connectivity at slightly different times.

multiplier The number of connected ping nodes gets multiplied


by this value to get a score. Useful when there are
multiple ping nodes configured.

host_list The machines to contact in order to determine the


current connectivity status. Allowed values include
resolvable DNS host names, IPv4 and IPv6
addresses. The entries in the host list are space
separated.

The following example command creates a ping resource that verifies connectivity to
gateway.example.com. In practice, you would verify connectivity to your network gateway/router. You
configure the ping resource as a clone so that the resource will run on all cluster nodes.

# pcs resource create ping ocf:pacemaker:ping dampen=5s multiplier=1000


host_list=gateway.example.com clone

The following example configures a location constraint rule for the existing resource named Webserver.
This will cause the Webserver resource to move to a host that is able to ping gateway.example.com if
the host that it is currently running on cannot ping www.example.com

# pcs constraint location Webserver rule score=-INFINITY pingd lt 1 or not_defined pingd

Module included in the following assemblies:


//
// <List assemblies here, each on a new line>
// rhel-8-docs/enterprise/assemblies/assembly_managing-cluster-resources.adoc

15.5. DISABLING A MONITOR OPERATION


The easiest way to stop a recurring monitor is to delete it. However, there can be times when you only
want to disable it temporarily. In such cases, add enabled="false" to the operation’s definition. When
you want to reinstate the monitoring operation, set enabled="true" to the operation’s definition.

When you update a resource’s operation with the pcs resource update command, any options you do
not specifically call out are reset to their default values. For example, if you have configured a
monitoring operation with a custom timeout value of 600, running the following commands will reset the
timeout value to the default value of 20 (or whatever you have set the default value to with the pcs
resource ops default command).

# pcs resource update resourceXZY op monitor enabled=false


# pcs resource update resourceXZY op monitor enabled=true

In order to maintain the original value of 600 for this option, when you reinstate the monitoring
96
CHAPTER 15. MANAGING CLUSTER RESOURCES

In order to maintain the original value of 600 for this option, when you reinstate the monitoring
operation you must specify that value, as in the following example.

# pcs resource update resourceXZY op monitor timeout=600 enabled=true

97
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 16. CREATING CLUSTER RESOURCES THAT ARE


ACTIVE ON MULTIPLE NODES (CLONED RESOURCES)
You can clone a cluster resource so that the resource can be active on multiple nodes. For example, you
can use cloned resources to configure multiple instances of an IP resource to distribute throughout a
cluster for node balancing. You can clone any resource provided the resource agent supports it. A clone
consists of one resource or one resource group.

NOTE

Only resources that can be active on multiple nodes at the same time are suitable for
cloning. For example, a Filesystem resource mounting a non-clustered file system such
as ext4 from a shared memory device should not be cloned. Since the ext4 partition is
not cluster aware, this file system is not suitable for read/write operations occurring from
multiple nodes at the same time.

16.1. CREATING AND REMOVING A CLONED RESOURCE


You can create a resource and a clone of that resource at the same time with the following command.

pcs resource create resource_id [standard:[provider:]]type [resource options] [meta resource meta
options] clone [clone options]

The name of the clone will be resource_id-clone.

You cannot create a resource group and a clone of that resource group in a single command.

Alternately, you can create a clone of a previously-created resource or resource group with the following
command.

pcs resource clone resource_id | group_name [clone options]...

The name of the clone will be resource_id-clone or group_name-clone.

NOTE

You need to configure resource configuration changes on one node only.

NOTE

When configuring constraints, always use the name of the group or clone.

When you create a clone of a resource, the clone takes on the name of the resource with -clone
appended to the name. The following commands creates a resource of type apache named webfarm
and a clone of that resource named webfarm-clone.

# pcs resource create webfarm apache clone

NOTE
98
CHAPTER 16. CREATING CLUSTER RESOURCES THAT ARE ACTIVE ON MULTIPLE NODES (CLONED RESOURCES)

NOTE

When you create a resource or resource group clone that will be ordered after another
clone, you should almost always set the interleave=true option. This ensures that copies
of the dependent clone can stop or start when the clone it depends on has stopped or
started on the same node. If you do not set this option, if a cloned resource B depends on
a cloned resource A and a node leaves the cluster, when the node returns to the cluster
and resource A starts on that node, then all of the copies of resource B on all of the
nodes will restart. This is because when a dependent cloned resource does not have the
interleave option set, all instances of that resource depend on any running instance of
the resource it depends on.

Use the following command to remove a clone of a resource or a resource group. This does not remove
the resource or resource group itself.

pcs resource unclone resource_id | group_name

Table 16.1, “Resource Clone Options” describes the options you can specify for a cloned resource.

Table 16.1. Resource Clone Options

Field Description

priority, target-role, is-managed Options inherited from resource that is being cloned,
as described in Table 9.3, “Resource Meta Options”.

clone-max How many copies of the resource to start. Defaults to


the number of nodes in the cluster.

clone-node-max How many copies of the resource can be started on a


single node; the default value is 1.

notify When stopping or starting a copy of the clone, tell all


the other copies beforehand and when the action was
successful. Allowed values: false, true. The default
value is false.

globally-unique Does each copy of the clone perform a different


function? Allowed values: false, true

If the value of this option is false, these resources


behave identically everywhere they are running and
thus there can be only one copy of the clone active
per machine.

If the value of this option is true, a copy of the clone


running on one machine is not equivalent to another
instance, whether that instance is running on another
node or on the same node. The default value is true
if the value of clone-node-max is greater than one;
otherwise the default value is false.

99
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Field Description

ordered Should the copies be started in series (instead of in


parallel). Allowed values: false, true. The default
value is false.

interleave Changes the behavior of ordering constraints


(between clones) so that copies of the first clone can
start or stop as soon as the copy on the same node
of the second clone has started or stopped (rather
than waiting until every instance of the second clone
has started or stopped). Allowed values: false, true.
The default value is false.

clone-min If a value is specified, any clones which are ordered


after this clone will not be able to start until the
specified number of instances of the original clone
are running, even if the interleave option is set to
true.

To achieve a stable allocation pattern, clones are slightly sticky by default, which indicates that they have
a slight preference for staying on the node where they are running. If no value for resource-stickiness
is provided, the clone will use a value of 1. Being a small value, it causes minimal disturbance to the score
calculations of other resources but is enough to prevent Pacemaker from needlessly moving copies
around the cluster. For information on setting the resource-stickiness resource meta-option, see
Configuring resource meta options.

16.2. CONFIGURING CLONE RESOURCE CONSTRAINTS


In most cases, a clone will have a single copy on each active cluster node. You can, however, set clone-
max for the resource clone to a value that is less than the total number of nodes in the cluster. If this is
the case, you can indicate which nodes the cluster should preferentially assign copies to with resource
location constraints. These constraints are written no differently to those for regular resources except
that the clone’s id must be used.

The following command creates a location constraint for the cluster to preferentially assign resource
clone webfarm-clone to node1.

# pcs constraint location webfarm-clone prefers node1

Ordering constraints behave slightly differently for clones. In the example below, because the
interleave clone option is left to default as false, no instance of webfarm-stats will start until all
instances of webfarm-clone that need to be started have done so. Only if no copies of webfarm-clone
can be started then webfarm-stats will be prevented from being active. Additionally, webfarm-clone
will wait for webfarm-stats to be stopped before stopping itself.

# pcs constraint order start webfarm-clone then webfarm-stats

Colocation of a regular (or group) resource with a clone means that the resource can run on any
100
CHAPTER 16. CREATING CLUSTER RESOURCES THAT ARE ACTIVE ON MULTIPLE NODES (CLONED RESOURCES)

Colocation of a regular (or group) resource with a clone means that the resource can run on any
machine with an active copy of the clone. The cluster will choose a copy based on where the clone is
running and the resource’s own location preferences.

Colocation between clones is also possible. In such cases, the set of allowed locations for the clone is
limited to nodes on which the clone is (or will be) active. Allocation is then performed as normally.

The following command creates a colocation constraint to ensure that the resource webfarm-stats runs
on the same node as an active copy of webfarm-clone.

# pcs constraint colocation add webfarm-stats with webfarm-clone

16.3. CREATING PROMOTABLE CLONE RESOURCES


Promotable clone resources are clone resources with the promotable meta attribute set to true. They
allow the instances to be in one of two operating modes; these are called Master and Slave. The names
of the modes do not have specific meanings, except for the limitation that when an instance is started, it
must come up in the Slave state.

16.3.1. Creating a promotable resource


You can create a resource as a promotable clone with the following single command.

pcs resource create resource_id [standard:[provider:]]type [resource options] promotable [clone


options]

The name of the promotable clone will be resource_id-clone.

Alternately, you can create a promotable resource from a previously-created resource or resource
group with the following command. The name of the promotable clone will be resource_id-clone or
group_name-clone.

pcs resource promotable resource_id [clone options]

Table 16.2, “Extra Clone Options Available for Promotable Clones” describes the extra clone options you
can specify for a promotable resource.

Table 16.2. Extra Clone Options Available for Promotable Clones

Field Description

promoted-max How many copies of the resource can be promoted;


default 1.

promoted-node-max How many copies of the resource can be promoted


on a single node; default 1.

16.3.2. Configuring promotable resource constraints


In most cases, a promotable resources will have a single copy on each active cluster node. If this is not
the case, you can indicate which nodes the cluster should preferentially assign copies to with resource
location constraints. These constraints are written no differently than those for regular resources.

101
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

You can create a colocation constraint which specifies whether the resources are operating in a master
or slave role. The following command creates a resource colocation constraint.

pcs constraint colocation add [master|slave] source_resource with [master|slave] target_resource


[score] [options]

For information on colocation constraints, see Colocating cluster resources .

When configuring an ordering constraint that includes promotable resources, one of the actions that you
can specify for the resources is promote, indicating that the resource be promoted from slave role to
master role. Additionally, you can specify an action of demote, indicated that the resource be demoted
from master role to slave role.

The command for configuring an order constraint is as follows.

pcs constraint order [action] resource_id then [action] resource_id [options]

For information on resource order constraints, see ifdef:: Determining the order in which cluster
resources are run.

102
CHAPTER 17. MANAGING CLUSTER NODES

CHAPTER 17. MANAGING CLUSTER NODES


The following sections describe the commands you use to manage cluster nodes, including commands to
start and stop cluster services and to add and remove cluster nodes.

17.1. STOPPING CLUSTER SERVICES


The following command stops cluster services on the specified node or nodes. As with the pcs cluster
start, the --all option stops cluster services on all nodes and if you do not specify any nodes, cluster
services are stopped on the local node only.

pcs cluster stop [--all | node] [...]

You can force a stop of cluster services on the local node with the following command, which performs a
kill -9 command.

pcs cluster kill

17.2. ENABLING AND DISABLING CLUSTER SERVICES


Use the following command to enables the cluster services, which configures the cluster services to run
on startup on the specified node or nodes. Enabling allows nodes to automatically rejoin the cluster
after they have been fenced, minimizing the time the cluster is at less than full strength. If the cluster
services are not enabled, an administrator can manually investigate what went wrong before starting the
cluster services manually, so that, for example, a node with hardware issues in not allowed back into the
cluster when it is likely to fail again.

If you specify the --all option, the command enables cluster services on all nodes.

If you do not specify any nodes, cluster services are enabled on the local node only.

pcs cluster enable [--all | node] [...]

Use the following command to configure the cluster services not to run on startup on the specified node
or nodes.

If you specify the --all option, the command disables cluster services on all nodes.

If you do not specify any nodes, cluster services are disabled on the local node only.

pcs cluster disable [--all | node] [...]

17.3. ADDING CLUSTER NODES

NOTE

It is highly recommended that you add nodes to existing clusters only during a production
maintenance window. This allows you to perform appropriate resource and deployment
testing for the new node and its fencing configuration.

Use the following procedure to add a new node to an existing cluster. This procedure adds standard

103
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Use the following procedure to add a new node to an existing cluster. This procedure adds standard
clusters nodes running corosync. For information on integrating non-corosync nodes into a cluster, see
Integrating non-corosync nodes into a cluster: the pacemaker_remote service .

In this example, the existing cluster nodes are clusternode-01.example.com, clusternode-


02.example.com, and clusternode-03.example.com. The new node is newnode.example.com.

On the new node to add to the cluster, perform the following tasks.

1. Install the cluster packages. If the cluster uses SBD, the Booth ticket manager, or a quorum
device, you must manually install the respective packages (sbd, booth-site, corosync-qdevice)
on the new node as well.

[root@newnode ~]# yum install -y pcs fence-agents-all

In addition to the cluster packages, you will also need to install and configure all of the services
that you are running in the cluster, which you have installed on the existing cluster nodes. For
example, if you are running an Apache HTTP server in a Red Hat high availability cluster, you will
need to install the server on the node you are adding, as well as the wget tool that checks the
status of the server.

2. If you are running the firewalld daemon, execute the following commands to enable the ports
that are required by the Red Hat High Availability Add-On.

# firewall-cmd --permanent --add-service=high-availability


# firewall-cmd --add-service=high-availability

3. Set a password for the user ID hacluster. It is recommended that you use the same password
for each node in the cluster.

[root@newnode ~]# passwd hacluster


Changing password for user hacluster.
New password:
Retype new password:
passwd: all authentication tokens updated successfully.

4. Execute the following commands to start the pcsd service and to enable pcsd at system start.

# systemctl start pcsd.service


# systemctl enable pcsd.service

On a node in the existing cluster, perform the following tasks.

1. Authenticate user hacluster on the new cluster node.

[root@clusternode-01 ~]# pcs host auth newnode.example.com


Username: hacluster
Password:
newnode.example.com: Authorized

2. Add the new node to the existing cluster. This command also syncs the cluster configuration file
corosync.conf to all nodes in the cluster, including the new node you are adding.

[root@clusternode-01 ~]# pcs cluster node add newnode.example.com

104
CHAPTER 17. MANAGING CLUSTER NODES

On the new node to add to the cluster, perform the following tasks.

1. Start and enable cluster services on the new node.

[root@newnode ~]# pcs cluster start


Starting Cluster...
[root@newnode ~]# pcs cluster enable

2. Ensure that you configure and test a fencing device for the new cluster node.

17.4. REMOVING CLUSTER NODES


The following command shuts down the specified node and removes it from the cluster configuration
file, corosync.conf, on all of the other nodes in the cluster.

pcs cluster node remove node

105
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 18. SETTING USER PERMISSIONS FOR A


PACEMAKER CLUSTER
You can grant permission for specific users other than user hacluster to manage a Pacemaker cluster.
There are two sets of permissions that you can grant to individual users:

Permissions that allow individual users to manage the cluster through the Web UI and to run
pcs commands that connect to nodes over a network. Commands that connect to nodes over a
network include commands to set up a cluster, or to add or remove nodes from a cluster.

Permissions for local users to allow read-only or read-write access to the cluster configuration.
Commands that do not require connecting over a network include commands that edit the
cluster configuration, such as those that create resources and configure constraints.

In situations where both sets of permissions have been assigned, the permissions for commands that
connect over a network are applied first, and then permissions for editing the cluster configuration on
the local node are applied. Most pcs commands do not require network access and in those cases the
network permissions will not apply.

18.1. SETTING PERMISSIONS FOR NODE ACCESS OVER A NETWORK


To grant permission for specific users to manage the cluster through the Web UI and to run pcs
commands that connect to nodes over a network, add those users to the group haclient.

18.2. SETTING LOCAL PERMISSIONS USING ACLS


You can use the pcs acl command to set permissions for local users to allow read-only or read-write
access to the cluster configuration by using access control lists (ACLs). By default, the root user and any
user who is a member of the group haclient has full local read/write access to the cluster configuration.

Setting permissions for local users is a two step process:

1. Execute the pcs acl role create…​ command to create a role which defines the permissions for
that role.

2. Assign the role you created to a user with the pcs acl user create command.

The following example procedure provides read-only access for a cluster configuration to a local user
named rouser.

1. This procedure requires that the user rouser exists on the local system and that the user
rouser is a member of the group haclient.

# adduser rouser
# usermod -a -G haclient rouser

2. Enable Pacemaker ACLs with the enable-acl cluster property.

# pcs property set enable-acl=true

3. Create a role named read-only with read-only permissions for the cib.

# pcs acl role create read-only description="Read access to cluster" read xpath /cib

106
CHAPTER 18. SETTING USER PERMISSIONS FOR A PACEMAKER CLUSTER

4. Create the user rouser in the pcs ACL system and assign that user the read-only role.

# pcs acl user create rouser read-only

5. View the current ACLs.

# pcs acl
User: rouser
Roles: read-only
Role: read-only
Description: Read access to cluster
Permission: read xpath /cib (read-only-read)

107
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 19. RESOURCE MONITORING OPERATIONS


To ensure that resources remain healthy, you can add a monitoring operation to a resource’s definition.
If you do not specify a monitoring operation for a resource, by default the pcs command will create a
monitoring operation, with an interval that is determined by the resource agent. If the resource agent
does not provide a default monitoring interval, the pcs command will create a monitoring operation with
an interval of 60 seconds.

Table 19.1, “Properties of an Operation” summarizes the properties of a resource monitoring operation.

Table 19.1. Properties of an Operation

Field Description

id Unique name for the action. The system assigns this when you configure an
operation.

name The action to perform. Common values: monitor, start, stop

interval If set to a nonzero value, a recurring operation is created that repeats at this
frequency, in seconds. A nonzero value makes sense only when the action name
is set to monitor. A recurring monitor action will be executed immediately after a
resource start completes, and subsequent monitor actions are scheduled starting
at the time the previous monitor action completed. For example, if a monitor
action with interval=20s is executed at 01:00:00, the next monitor action does
not occur at 01:00:20, but at 20 seconds after the first monitor action completes.

If set to zero, which is the default value, this parameter allows you to provide
values to be used for operations created by the cluster. For example, if the
interval is set to zero, the name of the operation is set to start, and the
timeout value is set to 40, then Pacemaker will use a timeout of 40 seconds
when starting this resource. A monitor operation with a zero interval allows you
to set the timeout / on-fail/ enabled values for the probes that Pacemaker does
at startup to get the current status of all resources when the defaults are not
desirable.

timeout If the operation does not complete in the amount of time set by this parameter,
abort the operation and consider it failed. The default value is the value of
timeout if set with the pcs resource op defaults command, or 20 seconds if it
is not set. If you find that your system includes a resource that requires more time
than the system allows to perform an operation (such as start, stop, or
monitor), investigate the cause and if the lengthy execution time is expected you
can increase this value.

The timeout value is not a delay of any kind, nor does the cluster wait the entire
timeout period if the operation returns before the timeout period has completed.

108
CHAPTER 19. RESOURCE MONITORING OPERATIONS

Field Description

on-fail The action to take if this action ever fails. Allowed values:

* ignore - Pretend the resource did not fail

* block - Do not perform any further operations on the resource

* stop - Stop the resource and do not start it elsewhere

* restart - Stop the resource and start it again (possibly on a different node)

* fence - STONITH the node on which the resource failed

* standby - Move all resources away from the node on which the resource failed

The default for the stop operation is fence when STONITH is enabled and block
otherwise. All other operations default to restart.

enabled If false, the operation is treated as if it does not exist. Allowed values:true, false

19.1. CONFIGURING RESOURCE MONITORING OPERATIONS


You can configure monitoring operations when you create a resource, using the following command.

pcs resource create resource_id standard:provider:type|type [resource_options] [op operation_action


operation_options [operation_type operation_options]...]

For example, the following command creates an IPaddr2 resource with a monitoring operation. The new
resource is called VirtualIP with an IP address of 192.168.0.99 and a netmask of 24 on eth2. A
monitoring operation will be performed every 30 seconds.

# pcs resource create VirtualIP ocf:heartbeat:IPaddr2 ip=192.168.0.99 cidr_netmask=24


nic=eth2 op monitor interval=30s

Alternately, you can add a monitoring operation to an existing resource with the following command.

pcs resource op add resource_id operation_action [operation_properties]

Use the following command to delete a configured resource operation.

pcs resource op remove resource_id operation_name operation_properties

NOTE

You must specify the exact operation properties to properly remove an existing
operation.

To change the values of a monitoring option, you can update the resource. For example, you can create
a VirtualIP with the following command.

109
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

# pcs resource create VirtualIP ocf:heartbeat:IPaddr2 ip=192.168.0.99 cidr_netmask=24


nic=eth2

By default, this command creates these operations.

Operations: start interval=0s timeout=20s (VirtualIP-start-timeout-20s)


stop interval=0s timeout=20s (VirtualIP-stop-timeout-20s)
monitor interval=10s timeout=20s (VirtualIP-monitor-interval-10s)

To change the stop timeout operation, execute the following command.

# pcs resource update VirtualIP op stop interval=0s timeout=40s

# pcs resource show VirtualIP


Resource: VirtualIP (class=ocf provider=heartbeat type=IPaddr2)
Attributes: ip=192.168.0.99 cidr_netmask=24 nic=eth2
Operations: start interval=0s timeout=20s (VirtualIP-start-timeout-20s)
monitor interval=10s timeout=20s (VirtualIP-monitor-interval-10s)
stop interval=0s timeout=40s (VirtualIP-name-stop-interval-0s-timeout-40s)

19.2. CONFIGURING GLOBAL RESOURCE OPERATION DEFAULTS


You can use the following command to set global default values for monitoring operations.

pcs resource op defaults [options]

For example, the following command sets a global default of a timeout value of 240 seconds for all
monitoring operations.

# pcs resource op defaults timeout=240s

To display the currently configured default values for monitoring operations, do not specify any options
when you execute the pcs resource op defaults command.

For example, following command displays the default monitoring operation values for a cluster which has
been configured with a timeout value of 240 seconds.

# pcs resource op defaults


timeout: 240s

Note that a cluster resource will use the global default only when the option is not specified in the
cluster resource definition. By default, resource agents define the timeout option for all operations. For
the global operation timeout value to be honored, you must create the cluster resource without the
timeout option explicitly or you must remove the timeout option by updating the cluster resource, as in
the following command.

# pcs resource update VirtualIP op monitor interval=10s

For example, after setting a global default of a timeout value of 240 seconds for all monitoring
operations and updating the cluster resource VirtualIP to remove the timeout value for the monitor
operation, the resource VirtualIP will then have timeout values for start, stop, and monitor operations

110
CHAPTER 19. RESOURCE MONITORING OPERATIONS

of 20s, 40s and 240s, respectively. The global default value for timeout operations is applied here only
on the monitor operation, where the default timeout option was removed by the previous command.

# pcs resource show VirtualIP


Resource: VirtualIP (class=ocf provider=heartbeat type=IPaddr2)
Attributes: ip=192.168.0.99 cidr_netmask=24 nic=eth2
Operations: start interval=0s timeout=20s (VirtualIP-start-timeout-20s)
monitor interval=10s (VirtualIP-monitor-interval-10s)
stop interval=0s timeout=40s (VirtualIP-name-stop-interval-0s-timeout-40s)

19.3. CONFIGURING MULTIPLE MONITORING OPERATIONS


You can configure a single resource with as many monitor operations as a resource agent supports. In
this way you can do a superficial health check every minute and progressively more intense ones at
higher intervals.

NOTE

When configuring multiple monitor operations, you must ensure that no two operations
are performed at the same interval.

To configure additional monitoring operations for a resource that supports more in-depth checks at
different levels, you add an OCF_CHECK_LEVEL=n option.

For example, if you configure the following IPaddr2 resource, by default this creates a monitoring
operation with an interval of 10 seconds and a timeout value of 20 seconds.

# pcs resource create VirtualIP ocf:heartbeat:IPaddr2 ip=192.168.0.99 cidr_netmask=24


nic=eth2

If the Virtual IP supports a different check with a depth of 10, the following command causes Pacemaker
to perform the more advanced monitoring check every 60 seconds in addition to the normal Virtual IP
check every 10 seconds. (As noted, you should not configure the additional monitoring operation with a
10-second interval as well.)

# pcs resource op add VirtualIP monitor interval=60s OCF_CHECK_LEVEL=10

111
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 20. PACEMAKER CLUSTER PROPERTIES


Cluster properties control how the cluster behaves when confronted with situations that may occur
during cluster operation.

20.1. SUMMARY OF CLUSTER PROPERTIES AND OPTIONS


Table 20.1, “Cluster Properties” summaries the Pacemaker cluster properties, showing the default values
of the properties and the possible values you can set for those properties.

NOTE

In addition to the properties described in this table, there are additional cluster properties
that are exposed by the cluster software. For these properties, it is recommended that
you not change their values from their defaults.

Table 20.1. Cluster Properties

Option Default Description

batch-limit 0 The number of resource actions that the


cluster is allowed to execute in parallel. The
"correct" value will depend on the speed and
load of your network and cluster nodes. The
default value of 0 means that the cluster will
dynamically impose a limit when any node
has a high CPU load.

migration-limit -1 (unlimited) The number of migration jobs that the


cluster is allowed to execute in parallel on a
node.

no-quorum-policy stop What to do when the cluster does not have


quorum. Allowed values:

* ignore - continue all resource management

* freeze - continue resource management,


but do not recover resources from nodes not
in the affected partition

* stop - stop all resources in the affected


cluster partition

* suicide - fence all nodes in the affected


cluster partition

symmetric-cluster true Indicates whether resources can run on any


node by default.

112
CHAPTER 20. PACEMAKER CLUSTER PROPERTIES

Option Default Description

stonith-enabled true Indicates that failed nodes and nodes with


resources that cannot be stopped should be
fenced. Protecting your data requires that
you set this true.

If true, or unset, the cluster will refuse to


start resources unless one or more
STONITH resources have been configured
also.

Red Hat only supports clusters with this


value set to true.

stonith-action reboot Action to send to STONITH device. Allowed


values: reboot, off. The value poweroff is
also allowed, but is only used for legacy
devices.

cluster-delay 60s Round trip delay over the network (excluding


action execution). The "correct" value will
depend on the speed and load of your
network and cluster nodes.

stop-orphan-resources true Indicates whether deleted resources should


be stopped.

stop-orphan-actions true Indicates whether deleted actions should be


canceled.

start-failure-is-fatal true Indicates whether a failure to start a


resource on a particular node prevents
further start attempts on that node. When
set to false, the cluster will decide whether
to try starting on the same node again based
on the resource’s current failure count and
migration threshold. For information on
setting the migration-threshold option
for a resource, see Configuring resource
meta options.

Setting start-failure-is-fatal to false


incurs the risk that this will allow one faulty
node that is unable to start a resource to
hold up all dependent actions. This is why
start-failure-is-fatal defaults to true. The
risk of setting start-failure-is-fatal=false
can be mitigated by setting a low migration
threshold so that other actions can proceed
after that many failures.

113
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Option Default Description

pe-error-series-max -1 (all) The number of scheduler inputs resulting in


ERRORs to save. Used when reporting
problems.

pe-warn-series-max -1 (all) The number of scheduler inputs resulting in


WARNINGs to save. Used when reporting
problems.

pe-input-series-max -1 (all) The number of "normal" scheduler inputs to


save. Used when reporting problems.

cluster-infrastructure The messaging stack on which Pacemaker is


currently running. Used for informational and
diagnostic purposes; not user-configurable.

dc-version Version of Pacemaker on the cluster’s


Designated Controller (DC). Used for
diagnostic purposes; not user-configurable.

cluster-recheck-interval 15 minutes Polling interval for time-based changes to


options, resource parameters and
constraints. Allowed values: Zero disables
polling, positive values are an interval in
seconds (unless other SI units are specified,
such as 5min).

maintenance-mode false Maintenance Mode tells the cluster to go to


a "hands off" mode, and not start or stop any
services until told otherwise. When
maintenance mode is completed, the cluster
does a sanity check of the current state of
any services, and then stops or starts any
that need it.

shutdown-escalation 20min The time after which to give up trying to


shut down gracefully and just exit. Advanced
use only.

stonith-timeout 60s How long to wait for a STONITH action to


complete.

stop-all-resources false Should the cluster stop all resources.

enable-acl false Indicates whether the cluster can use access


control lists, as set with the pcs acl
command.

114
CHAPTER 20. PACEMAKER CLUSTER PROPERTIES

Option Default Description

placement-strategy default Indicates whether and how the cluster will


take utilization attributes into account when
determining resource placement on cluster
nodes.

20.2. SETTING AND REMOVING CLUSTER PROPERTIES


To set the value of a cluster property, use the following pcs command.

pcs property set property=value

For example, to set the value of symmetric-cluster to false, use the following command.

# pcs property set symmetric-cluster=false

You can remove a cluster property from the configuration with the following command.

pcs property unset property

Alternately, you can remove a cluster property from a configuration by leaving the value field of the pcs
property set command blank. This restores that property to its default value. For example, if you have
previously set the symmetric-cluster property to false, the following command removes the value you
have set from the configuration and restores the value of symmetric-cluster to true, which is its default
value.

# pcs property set symmetic-cluster=

20.3. QUERYING CLUSTER PROPERTY SETTINGS


In most cases, when you use the pcs command to display values of the various cluster components, you
can use pcs list or pcs show interchangeably. In the following examples, pcs list is the format used to
display an entire list of all settings for more than one property, while pcs show is the format used to
display the values of a specific property.

To display the values of the property settings that have been set for the cluster, use the following pcs
command.

pcs property list

To display all of the values of the property settings for the cluster, including the default values of the
property settings that have not been explicitly set, use the following command.

pcs property list --all

To display the current value of a specific cluster property, use the following command.

pcs property show property

For example, to display the current value of the cluster-infrastructure property, execute the following
115
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

For example, to display the current value of the cluster-infrastructure property, execute the following
command:

# pcs property show cluster-infrastructure


Cluster Properties:
cluster-infrastructure: cman

For informational purposes, you can display a list of all of the default values for the properties, whether
they have been set to a value other than the default or not, by using the following command.

pcs property [list|show] --defaults

116
CHAPTER 21. CONFIGURING A NODE PLACEMENT STRATEGY

CHAPTER 21. CONFIGURING A NODE PLACEMENT STRATEGY


Pacemaker decides where to place a resource according to the resource allocation scores on every
node. The resource will be allocated to the node where the resource has the highest score. This
allocation score is derived from a combination of factors, including resource constraints, resource-
stickiness settings, prior failure history of a resource on each node, and utilization of each node.

If the resource allocation scores on all the nodes are equal, by the default placement strategy
Pacemaker will choose a node with the least number of allocated resources for balancing the load. If the
number of resources on each node is equal, the first eligible node listed in the CIB will be chosen to run
the resource.

Often, however, different resources use significantly different proportions of a node’s capacities (such
as memory or I/O). You cannot always balance the load ideally by taking into account only the number
of resources allocated to a node. In addition, if resources are placed such that their combined
requirements exceed the provided capacity, they may fail to start completely or they may run run with
degraded performance. To take these factors into account, Pacemaker allows you to configure the
following components:

the capacity a particular node provides

the capacity a particular resource requires

an overall strategy for placement of resources

21.1. UTILIZATION ATTRIBUTES AND PLACEMENT STRATEGY


To configure the capacity that a node provides or a resource requires, you can use utilization attributes
for nodes and resources. You do this by setting a utilization variable for a resource and assigning a value
to that variable to indicate what the resource requires, and then setting that same utilization variable for
a node and assigning a value to that variable to indicate what that node provides.

You can name utilization attributes according to your preferences and define as many name and value
pairs as your configuration needs. The values of utilization attributes must be integers.

21.1.1. Configuring node and resource capacity


The following example configures a utilization attribute of CPU capacity for two nodes, setting this
attribute as the variable cpu. It also configures a utilization attribute of RAM capacity, setting this
attribute as the variable memory. In this example:

Node 1 is defined as providing a CPU capacity of two and a RAM capacity of 2048

Node 2 is defined as providing a CPU capacity of four and a RAM capacity of 2048

# pcs node utilization node1 cpu=2 memory=2048


# pcs node utilization node2 cpu=4 memory=2048

The following example specifies the same utilization attributes that three different resources require. In
this example:

resource dummy-small requires a CPU capacity of 1 and a RAM capacity of 1024

resource dummy-medium requires a CPU capacity of 2 and a RAM capacity of 2048

117
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

resource dummy-large requires a CPU capacity of 1 and a RAM capacity of 3072

# pcs resource utilization dummy-small cpu=1 memory=1024


# pcs resource utilization dummy-medium cpu=2 memory=2048
# pcs resource utilization dummy-large cpu=3 memory=3072

A node is considered eligible for a resource if it has sufficient free capacity to satisfy the resource’s
requirements, as defined by the utilization attributes.

21.1.2. Configuring placement strategy


After you have configured the capacities your nodes provide and the capacities your resources require,
you need to set the placement-strategy cluster property, otherwise the capacity configurations have
no effect.

Four values are available for the placement-strategy cluster property:

default — Utilization values are not taken into account at all. Resources are allocated according
to allocation scores. If scores are equal, resources are evenly distributed across nodes.

utilization — Utilization values are taken into account only when deciding whether a node is
considered eligible (that is, whether it has sufficient free capacity to satisfy the resource’s
requirements). Load-balancing is still done based on the number of resources allocated to a
node.

balanced — Utilization values are taken into account when deciding whether a node is eligible to
serve a resource and when load-balancing, so an attempt is made to spread the resources in a
way that optimizes resource performance.

minimal — Utilization values are taken into account only when deciding whether a node is
eligible to serve a resource. For load-balancing, an attempt is made to concentrate the
resources on as few nodes as possible, thereby enabling possible power savings on the
remaining nodes.

The following example command sets the value of placement-strategy to balanced. After running this
command, Pacemaker will ensure the load from your resources will be distributed evenly throughout the
cluster, without the need for complicated sets of colocation constraints.

# pcs property set placement-strategy=balanced

21.2. PACEMAKER RESOURCE ALLOCATION


The following subsections summarize how Pacemaker allocates resources.

21.2.1. Node Preference


Pacemaker determines which node is preferred when allocating resources according to the following
strategy.

The node with the highest node weight gets consumed first. Node weight is a score maintained
by the cluster to represent node health.

If multiple nodes have the same node weight:

If the placement-strategy cluster property is default or utilization:

118
CHAPTER 21. CONFIGURING A NODE PLACEMENT STRATEGY

The node that has the least number of allocated resources gets consumed first.

If the numbers of allocated resources are equal, the first eligible node listed in the CIB
gets consumed first.

If the placement-strategy cluster property is balanced:

The node that has the most free capacity gets consumed first.

If the free capacities of the nodes are equal, the node that has the least number of
allocated resources gets consumed first.

If the free capacities of the nodes are equal and the number of allocated resources is
equal, the first eligible node listed in the CIB gets consumed first.

If the placement-strategy cluster property is minimal, the first eligible node listed in the
CIB gets consumed first.

21.2.2. Node Capacity


Pacemaker determines which node has the most free capacity according to the following strategy.

If only one type of utilization attribute has been defined, free capacity is a simple numeric
comparison.

If multiple types of utilization attributes have been defined, then the node that is numerically
highest in the most attribute types has the most free capacity. For example:

If NodeA has more free CPUs, and NodeB has more free memory, then their free capacities
are equal.

If NodeA has more free CPUs, while NodeB has more free memory and storage, then
NodeB has more free capacity.

21.2.3. Resource Allocation Preference


Pacemaker determines which resource is allocated first according to the following strategy.

The resource that has the highest priority gets allocated first. You can set a resource’s priority
when you create the resource.

If the priorities of the resources are equal, the resource that has the highest score on the node
where it is running gets allocated first, to prevent resource shuffling.

If the resource scores on the nodes where the resources are running are equal or the resources
are not running, the resource that has the highest score on the preferred node gets allocated
first. If the resource scores on the preferred node are equal in this case, the first runnable
resource listed in the CIB gets allocated first.

21.3. RESOURCE PLACEMENT STRATEGY GUIDELINES


To ensure that Pacemaker’s placement strategy for resources works most effectively, you should take
the following considerations into account when configuring your system.

Make sure that you have sufficient physical capacity.

If the physical capacity of your nodes is being used to near maximum under normal conditions,

119
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

If the physical capacity of your nodes is being used to near maximum under normal conditions,
then problems could occur during failover. Even without the utilization feature, you may start to
experience timeouts and secondary failures.

Build some buffer into the capabilities you configure for the nodes.
Advertise slightly more node resources than you physically have, on the assumption the that a
Pacemaker resource will not use 100% of the configured amount of CPU, memory, and so forth
all the time. This practice is sometimes called overcommit.

Specify resource priorities.


If the cluster is going to sacrifice services, it should be the ones you care about least. Ensure that
resource priorities are properly set so that your most important resources are scheduled first.

21.4. THE NODEUTILIZATION RESOURCE AGENT


The NodeUtilization agent can detect the system parameters of available CPU, host memory availability,
and hypervisor memory availability and add these parameters into the CIB. You can run the agent as a
clone resource to have it automatically populate these parameters on each node.

For information on the NodeUtilization resource agent and the resource options for this agent, run the
pcs resource describe NodeUtilization command.

120
CHAPTER 22. CONFIGURING A VIRTUAL DOMAIN AS A RESOURCE

CHAPTER 22. CONFIGURING A VIRTUAL DOMAIN AS A


RESOURCE
You can configure a virtual domain that is managed by the libvirt virtualization framework as a cluster
resource with the pcs resource create command, specifying VirtualDomain as the resource type.

When configuring a virtual domain as a resource, take the following considerations into account:

A virtual domain should be stopped before you configure it as a cluster resource.

Once a virtual domain is a cluster resource, it should not be started, stopped, or migrated except
through the cluster tools.

Do not configure a virtual domain that you have configured as a cluster resource to start when
its host boots.

All nodes allowed to run a virtual domain must have access to the necessary configuration files
and storage devices for that virtual domain.

If you want the cluster to manage services within the virtual domain itself, you can configure the virtual
domain as a guest node.

22.1. VIRTUAL DOMAIN RESOURCE OPTIONS


Table 22.1, “Resource Options for Virtual Domain Resources” describes the resource options you can
configure for a VirtualDomain resource.

Table 22.1. Resource Options for Virtual Domain Resources

Field Default Description

config (required) Absolute path to the libvirt


configuration file for this virtual
domain.

hypervisor System dependent Hypervisor URI to connect to. You can


determine the system’s default URI by
running the virsh --quiet uri
command.

force_stop 0 Always forcefully shut down


("destroy") the domain on stop. The
default behavior is to resort to a
forceful shutdown only after a graceful
shutdown attempt has failed. You
should set this to true only if your
virtual domain (or your virtualization
back end) does not support graceful
shutdown.

121
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Field Default Description

migration_transport System dependent Transport used to connect to the


remote hypervisor while migrating. If
this parameter is omitted, the resource
will use libvirt's default transport to
connect to the remote hypervisor.

migration_network_suffix Use a dedicated migration network.


The migration URI is composed by
adding this parameter’s value to the
end of the node name. If the node
name is a fully qualified domain name
(FQDN), insert the suffix immediately
prior to the first period (.) in the FQDN.
Ensure that this composed host name
is locally resolvable and the associated
IP address is reachable through the
favored network.

monitor_scripts To additionally monitor services within


the virtual domain, add this parameter
with a list of scripts to monitor. Note:
When monitor scripts are used, the
start and migrate_from operations
will complete only when all monitor
scripts have completed successfully.
Be sure to set the timeout of these
operations to accommodate this delay

autoset_utilization_cpu true If set to true, the agent will detect the


number of domainU's vCPUs from
virsh, and put it into the CPU
utilization of the resource when the
monitor is executed.

autoset_utilization_hv_memory true If set it true, the agent will detect the


number of Max memory from virsh,
and put it into the hv_memory
utilization of the source when the
monitor is executed.

migrateport random highport This port will be used in the qemu


migrate URI. If unset, the port will be a
random highport.

122
CHAPTER 22. CONFIGURING A VIRTUAL DOMAIN AS A RESOURCE

Field Default Description

snapshot Path to the snapshot directory where


the virtual machine image will be
stored. When this parameter is set, the
virtual machine’s RAM state will be
saved to a file in the snapshot
directory when stopped. If on start a
state file is present for the domain, the
domain will be restored to the same
state it was in right before it stopped
last. This option is incompatible with
the force_stop option.

In addition to the VirtualDomain resource options, you can configure the allow-migrate metadata
option to allow live migration of the resource to another node. When this option is set to true, the
resource can be migrated without loss of state. When this option is set to false, which is the default
state, the virtual domain will be shut down on the first node and then restarted on the second node
when it is moved from one node to the other.

22.2. CREATING THE VIRTUAL DOMAIN RESOURCE


Use the following procedure to create a VirtualDomain resource:

1. To create the VirtualDomain resource agent for the management of the virtual machine,
Pacemaker requires the virtual machine’s xml configuration file to be dumped to a file on disk.
For example, if you created a virtual machine named guest1, dump the xml file to a file
somewhere on the host. You can use a file name of your choosing; this example uses
/etc/pacemaker/guest1.xml.

# virsh dumpxml guest1 > /etc/pacemaker/guest1.xml

2. If it is running, shut down the guest node. Pacemaker will start the node when it is configured in
the cluster.

3. Configure the VirtualDoman resource with the pcs resource create command. For example,
The following command configures a VirtualDomain resource named VM. Since the allow-
migrate option is set to true a pcs move VM nodeX command would be done as a live
migration.

# pcs resource create VM VirtualDomain config=.../vm.xml \


migration_transport=ssh meta allow-migrate=true

123
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 23. CLUSTER QUORUM


A Red Hat Enterprise Linux High Availability Add-On cluster uses the votequorum service, in
conjunction with fencing, to avoid split brain situations. A number of votes is assigned to each system in
the cluster, and cluster operations are allowed to proceed only when a majority of votes is present. The
service must be loaded into all nodes or none; if it is loaded into a subset of cluster nodes, the results will
be unpredictable. For information on the configuration and operation of the votequorum service, see
the votequorum(5) man page.

23.1. CONFIGURING QUORUM OPTIONS


There are some special features of quorum configuration that you can set when you create a cluster with
the pcs cluster setup command. Table 23.1, “Quorum Options” summarizes these options.

Table 23.1. Quorum Options

Option Description

auto_tie_breaker When enabled, the cluster can suffer up to 50% of the


nodes failing at the same time, in a deterministic fashion.
The cluster partition, or the set of nodes that are still in
contact with the nodeid configured in
auto_tie_breaker_node (or lowest nodeid if not set),
will remain quorate. The other nodes will be inquorate.

The auto_tie_breaker option is principally used for


clusters with an even number of nodes, as it allows the
cluster to continue operation with an even split. For more
complex failures, such as multiple, uneven splits, it is
recommended that you use a quorum device, as described
in Quorum devices.

The auto_tie_breaker option is incompatible with quorum


devices.

wait_for_all When enabled, the cluster will be quorate for the first time
only after all nodes have been visible at least once at the
same time.

The wait_for_all option is primarily used for two-node


clusters and for even-node clusters using the quorum
device lms (last man standing) algorithm.

The wait_for_all option is automatically enabled when a


cluster has two nodes, does not use a quorum device, and
auto_tie_breaker is disabled. You can override this by
explicitly setting wait_for_all to 0.

last_man_standing When enabled, the cluster can dynamically recalculate


expected_votes and quorum under specific
circumstances. You must enable wait_for_all when you
enable this option. The last_man_standing option is
incompatible with quorum devices.

124
CHAPTER 23. CLUSTER QUORUM

Option Description

last_man_standing_window The time, in milliseconds, to wait before recalculating


expected_votes and quorum after a cluster loses nodes.

For further information about configuring and using these options, see the votequorum(5) man page.

23.2. MODIFYING QUORUM OPTIONS


You can modify general quorum options for your cluster with the pcs quorum update command.
Executing this command requires that the cluster be stopped. For information on the quorum options,
see the votequorum(5) man page.

The format of the pcs quorum update command is as follows.

pcs quorum update [auto_tie_breaker=[0|1]] [last_man_standing=[0|1]] [last_man_standing_window=


[time-in-ms] [wait_for_all=[0|1]]

The following series of commands modifies the wait_for_all quorum option and displays the updated
status of the option. Note that the system does not allow you to execute this command while the cluster
is running.

[root@node1:~]# pcs quorum update wait_for_all=1


Checking corosync is not running on nodes...
Error: node1: corosync is running
Error: node2: corosync is running

[root@node1:~]# pcs cluster stop --all


node2: Stopping Cluster (pacemaker)...
node1: Stopping Cluster (pacemaker)...
node1: Stopping Cluster (corosync)...
node2: Stopping Cluster (corosync)...

[root@node1:~]# pcs quorum update wait_for_all=1


Checking corosync is not running on nodes...
node2: corosync is not running
node1: corosync is not running
Sending updated corosync.conf to nodes...
node1: Succeeded
node2: Succeeded

[root@node1:~]# pcs quorum config


Options:
wait_for_all: 1

23.3. DISPLAYING QUORUM CONFIGURATION AND STATUS


Once a cluster is running, you can enter the following cluster quorum commands.

The following command shows the quorum configuration.

125
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

pcs quorum [config]

The following command shows the quorum runtime status.

pcs quorum status

23.4. RUNNING INQUORATE CLUSTERS


If you take nodes out of a cluster for a long period of time and the loss of those nodes would cause
quorum loss, you can change the value of the expected_votes parameter for the live cluster with the
pcs quorum expected-votes command. This allows the cluster to continue operation when it does not
have quorum.


WARNING

Changing the expected votes in a live cluster should be done with extreme caution.
If less than 50% of the cluster is running because you have manually changed the
expected votes, then the other nodes in the cluster could be started separately and
run cluster services, causing data corruption and other unexpected results. If you
change this value, you should ensure that the wait_for_all parameter is enabled.

The following command sets the expected votes in the live cluster to the specified value. This affects
the live cluster only and does not change the configuration file; the value of expected_votes is reset to
the value in the configuration file in the event of a reload.

pcs quorum expected-votes votes

In a situation in which you know that the cluster is inquorate but you want the cluster to proceed with
resource management, you can use the pcs quorum unblock command to prevent the cluster from
waiting for all nodes when establishing quorum.

NOTE

This command should be used with extreme caution. Before issuing this command, it is
imperative that you ensure that nodes that are not currently in the cluster are switched
off and have no access to shared resources.

# pcs quorum unblock

23.5. QUORUM DEVICES


You can allow a cluster to sustain more node failures than standard quorum rules allows by configuring a
separate quorum device which acts as a third-party arbitration device for the cluster. A quorum device is
recommended for clusters with an even number of nodes and highly recommended for two-node
clusters.

You must take the following into account when configuring a quorum device.

126
CHAPTER 23. CLUSTER QUORUM

It is recommended that a quorum device be run on a different physical network at the same site
as the cluster that uses the quorum device. Ideally, the quorum device host should be in a
separate rack than the main cluster, or at least on a separate PSU and not on the same network
segment as the corosync ring or rings.

You cannot use more than one quorum device in a cluster at the same time.

Although you cannot use more than one quorum device in a cluster at the same time, a single
quorum device may be used by several clusters at the same time. Each cluster using that
quorum device can use different algorithms and quorum options, as those are stored on the
cluster nodes themselves. For example, a single quorum device can be used by one cluster with
an ffsplit (fifty/fifty split) algorithm and by a second cluster with an lms (last man standing)
algorithm.

A quorum device should not be run on an existing cluster node.

23.5.1. Installing quorum device packages


Configuring a quorum device for a cluster requires that you install the following packages:

Install corosync-qdevice on the nodes of an existing cluster.

[root@node1:~]# yum install corosync-qdevice


[root@node2:~]# yum install corosync-qdevice

Install pcs and corosync-qnetd on the quorum device host.

[root@qdevice:~]# yum install pcs corosync-qnetd

Start the pcsd service and enable pcsd at system start on the quorum device host.

[root@qdevice:~]# systemctl start pcsd.service


[root@qdevice:~]# systemctl enable pcsd.service

23.5.2. Configuring a quorum device


The following procedure configures a quorum device and adds it to the cluster. In this example:

The node used for a quorum device is qdevice.

The quorum device model is net, which is currently the only supported model. The net model
supports the following algorithms:

ffsplit: fifty-fifty split. This provides exactly one vote to the partition with the highest
number of active nodes.

lms: last-man-standing. If the node is the only one left in the cluster that can see the qnetd
server, then it returns a vote.

127
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters


WARNING

The LMS algorithm allows the cluster to remain quorate even with only
one remaining node, but it also means that the voting power of the
quorum device is great since it is the same as number_of_nodes - 1.
Losing connection with the quorum device means losing
number_of_nodes - 1 votes, which means that only a cluster with all
nodes active can remain quorate (by overvoting the quorum device);
any other cluster becomes inquorate.

For more detailed information on the implementation of these algorithms, see the
corosync-qdevice(8) man page.

The cluster nodes are node1 and node2.

The following procedure configures a quorum device and adds that quorum device to a cluster.

1. On the node that you will use to host your quorum device, configure the quorum device with the
following command. This command configures and starts the quorum device model net and
configures the device to start on boot.

[root@qdevice:~]# pcs qdevice setup model net --enable --start


Quorum device 'net' initialized
quorum device enabled
Starting quorum device...
quorum device started

After configuring the quorum device, you can check its status. This should show that the
corosync-qnetd daemon is running and, at this point, there are no clients connected to it. The -
-full command option provides detailed output.

[root@qdevice:~]# pcs qdevice status net --full


QNetd address: *:5403
TLS: Supported (client certificate required)
Connected clients: 0
Connected clusters: 0
Maximum send/receive size: 32768/32768 bytes

2. Enable the ports on the firewall needed by the pcsd daemon and the net quorum device by
enabling the high-availability service on firewalld with following commands.

[root@qdevice:~]# firewall-cmd --permanent --add-service=high-availability


[root@qdevice:~]# firewall-cmd --add-service=high-availability

3. From one of the nodes in the existing cluster, authenticate user hacluster on the node that is
hosting the quorum device. This allows pcs on the cluster to connect to pcs on the qdevice
host, but does not allow pcs on the qdevice host to connect to pcs on the cluster.

[root@node1:~] # pcs host auth qdevice


Username: hacluster

128
CHAPTER 23. CLUSTER QUORUM

Password:
qdevice: Authorized

4. Add the quorum device to the cluster.


Before adding the quorum device, you can check the current configuration and status for the
quorum device for later comparison. The output for these commands indicates that the cluster
is not yet using a quorum device.

[root@node1:~]# pcs quorum config


Options:

[root@node1:~]# pcs quorum status


Quorum information
------------------
Date: Wed Jun 29 13:15:36 2016
Quorum provider: corosync_votequorum
Nodes: 2
Node ID: 1
Ring ID: 1/8272
Quorate: Yes

Votequorum information
----------------------
Expected votes: 2
Highest expected: 2
Total votes: 2
Quorum: 1
Flags: 2Node Quorate

Membership information
----------------------
Nodeid Votes Qdevice Name
1 1 NR node1 (local)
2 1 NR node2

The following command adds the quorum device that you have previously created to the
cluster. You cannot use more than one quorum device in a cluster at the same time. However,
one quorum device can be used by several clusters at the same time. This example command
configures the quorum device to use the ffsplit algorithm. For information on the configuration
options for the quorum device, see the corosync-qdevice(8) man page.

[root@node1:~]# pcs quorum device add model net host=qdevice algorithm=ffsplit


Setting up qdevice certificates on nodes...
node2: Succeeded
node1: Succeeded
Enabling corosync-qdevice...
node1: corosync-qdevice enabled
node2: corosync-qdevice enabled
Sending updated corosync.conf to nodes...
node1: Succeeded
node2: Succeeded
Corosync configuration reloaded
Starting corosync-qdevice...
node1: corosync-qdevice started
node2: corosync-qdevice started

129
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

5. Check the configuration status of the quorum device.


From the cluster side, you can execute the following commands to see how the configuration
has changed.

The pcs quorum config shows the quorum device that has been configured.

[root@node1:~]# pcs quorum config


Options:
Device:
Model: net
algorithm: ffsplit
host: qdevice

The pcs quorum status command shows the quorum runtime status, indicating that the
quorum device is in use.

[root@node1:~]# pcs quorum status


Quorum information
------------------
Date: Wed Jun 29 13:17:02 2016
Quorum provider: corosync_votequorum
Nodes: 2
Node ID: 1
Ring ID: 1/8272
Quorate: Yes

Votequorum information
----------------------
Expected votes: 3
Highest expected: 3
Total votes: 3
Quorum: 2
Flags: Quorate Qdevice

Membership information
----------------------
Nodeid Votes Qdevice Name
1 1 A,V,NMW node1 (local)
2 1 A,V,NMW node2
0 1 Qdevice

The pcs quorum device status shows the quorum device runtime status.

[root@node1:~]# pcs quorum device status


Qdevice information
-------------------
Model: Net
Node ID: 1
Configured node list:
0 Node ID = 1
1 Node ID = 2
Membership node list: 1, 2

Qdevice-net information

130
CHAPTER 23. CLUSTER QUORUM

----------------------
Cluster name: mycluster
QNetd host: qdevice:5403
Algorithm: ffsplit
Tie-breaker: Node with lowest node ID
State: Connected

From the quorum device side, you can execute the following status command, which shows the
status of the corosync-qnetd daemon.

[root@qdevice:~]# pcs qdevice status net --full


QNetd address: *:5403
TLS: Supported (client certificate required)
Connected clients: 2
Connected clusters: 1
Maximum send/receive size: 32768/32768 bytes
Cluster "mycluster":
Algorithm: ffsplit
Tie-breaker: Node with lowest node ID
Node ID 2:
Client address: ::ffff:192.168.122.122:50028
HB interval: 8000ms
Configured node list: 1, 2
Ring ID: 1.2050
Membership node list: 1, 2
TLS active: Yes (client certificate verified)
Vote: ACK (ACK)
Node ID 1:
Client address: ::ffff:192.168.122.121:48786
HB interval: 8000ms
Configured node list: 1, 2
Ring ID: 1.2050
Membership node list: 1, 2
TLS active: Yes (client certificate verified)
Vote: ACK (ACK)

23.5.3. Managing the Quorum Device Service


PCS provides the ability to manage the quorum device service on the local host (corosync-qnetd), as
shown in the following example commands. Note that these commands affect only the corosync-qnetd
service.

[root@qdevice:~]# pcs qdevice start net


[root@qdevice:~]# pcs qdevice stop net
[root@qdevice:~]# pcs qdevice enable net
[root@qdevice:~]# pcs qdevice disable net
[root@qdevice:~]# pcs qdevice kill net

23.5.4. Managing the quorum device settings in a cluster


The following sections describe the PCS commands that you can use to manage the quorum device
settings in a cluster.

23.5.4.1. Changing quorum device settings

131
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

You can change the setting of a quorum device with the pcs quorum device update command.


WARNING

To change the host option of quorum device model net, use the pcs quorum
device remove and the pcs quorum device add commands to set up the
configuration properly, unless the old and the new host are the same machine.

The following command changes the quorum device algorithm to lms.

[root@node1:~]# pcs quorum device update model algorithm=lms


Sending updated corosync.conf to nodes...
node1: Succeeded
node2: Succeeded
Corosync configuration reloaded
Reloading qdevice configuration on nodes...
node1: corosync-qdevice stopped
node2: corosync-qdevice stopped
node1: corosync-qdevice started
node2: corosync-qdevice started

23.5.4.2. Removing a quorum device

Use the following command to remove a quorum device configured on a cluster node.

[root@node1:~]# pcs quorum device remove


Sending updated corosync.conf to nodes...
node1: Succeeded
node2: Succeeded
Corosync configuration reloaded
Disabling corosync-qdevice...
node1: corosync-qdevice disabled
node2: corosync-qdevice disabled
Stopping corosync-qdevice...
node1: corosync-qdevice stopped
node2: corosync-qdevice stopped
Removing qdevice certificates from nodes...
node1: Succeeded
node2: Succeeded

After you have removed a quorum device, you should see the following error message when displaying
the quorum device status.

[root@node1:~]# pcs quorum device status


Error: Unable to get quorum status: corosync-qdevice-tool: Can't connect to QDevice socket (is
QDevice running?): No such file or directory

23.5.4.3. Destroying a quorum device

132
CHAPTER 23. CLUSTER QUORUM

To disable and stop a quorum device on the quorum device host and delete all of its configuration files,
use the following command.

[root@qdevice:~]# pcs qdevice destroy net


Stopping quorum device...
quorum device stopped
quorum device disabled
Quorum device 'net' configuration files removed

133
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 24. TRIGGERING SCRIPTS FOR CLUSTER EVENTS


A Pacemaker cluster is an event-driven system, where an event might be a resource or node failure, a
configuration change, or a resource starting or stopping. You can configure Pacemaker cluster alerts to
take some external action when a cluster event occurs by means of alert agents, which are external
programs that the cluster calls in the same manner as the cluster calls resource agents to handle
resource configuration and operation.

The cluster passes information about the event to the agent by means of environment variables. Agents
can do anything with this information, such as send an email message or log to a file or update a
monitoring system.

Pacemaker provides several sample alert agents, which are installed in


/usr/share/pacemaker/alerts by default. These sample scripts may be copied and used as is, or
they may be used as templates to be edited to suit your purposes. Refer to the source code of
the sample agents for the full set of attributes they support.

If the sample alert agents do not meet your needs, you can write your own alert agents for a
Pacemaker alert to call.

24.1. INSTALLING AND CONFIGURING SAMPLE ALERT AGENTS


When you use one of the sample alert agents, you should review the script to ensure that it suits your
needs. These sample agents are provided as a starting point for custom scripts for specific cluster
environments. Note that while Red Hat supports the interfaces that the alert agents scripts use to
communicate with Pacemaker, Red Hat does not provide support for the custom agents themselves.

To use one of the sample alert agents, you must install the agent on each node in the cluster. For
example, the following command installs the alert_file.sh.sample script as alert_file.sh.

# install --mode=0755 /usr/share/pacemaker/alerts/alert_file.sh.sample


/var/lib/pacemaker/alert_file.sh

After you have installed the script, you can create an alert that uses the script.

The following example configures an alert that uses the installed alert_file.sh alert agent to log events
to a file. Alert agents run as the user hacluster, which has a minimal set of permissions.

This example creates the log file pcmk_alert_file.log that will be used to record the events. It then
creates the alert agent and adds the path to the log file as its recipient.

# touch /var/log/pcmk_alert_file.log
# chown hacluster:haclient /var/log/pcmk_alert_file.log
# chmod 600 /var/log/pcmk_alert_file.log
# pcs alert create id=alert_file description="Log events to a file."
path=/var/lib/pacemaker/alert_file.sh
# pcs alert recipient add alert_file id=my-alert_logfile value=/var/log/pcmk_alert_file.log

The following example installs the alert_snmp.sh.sample script as alert_snmp.sh and configures an
alert that uses the installed alert_snmp.sh alert agent to send cluster events as SNMP traps. By default,
the script will send all events except successful monitor calls to the SNMP server. This example
configures the timestamp format as a meta option. After configuring the alert, this example configures a
recipient for the alert and displays the alert configuration.

134
CHAPTER 24. TRIGGERING SCRIPTS FOR CLUSTER EVENTS

# install --mode=0755 /usr/share/pacemaker/alerts/alert_snmp.sh.sample


/var/lib/pacemaker/alert_snmp.sh
# pcs alert create id=snmp_alert path=/var/lib/pacemaker/alert_snmp.sh meta timestamp-
format="%Y-%m-%d,%H:%M:%S.%01N"
# pcs alert recipient add snmp_alert value=192.168.1.2
# pcs alert
Alerts:
Alert: snmp_alert (path=/var/lib/pacemaker/alert_snmp.sh)
Meta options: timestamp-format=%Y-%m-%d,%H:%M:%S.%01N.
Recipients:
Recipient: snmp_alert-recipient (value=192.168.1.2)

The following example installs the alert_smtp.sh agent and then configures an alert that uses the
installed alert agent to send cluster events as email messages. After configuring the alert, this example
configures a recipient and displays the alert configuration.

# install --mode=0755 /usr/share/pacemaker/alerts/alert_smtp.sh.sample


/var/lib/pacemaker/alert_smtp.sh
# pcs alert create id=smtp_alert path=/var/lib/pacemaker/alert_smtp.sh options
[email protected]
# pcs alert recipient add smtp_alert [email protected]
# pcs alert
Alerts:
Alert: smtp_alert (path=/var/lib/pacemaker/alert_smtp.sh)
Options: [email protected]
Recipients:
Recipient: smtp_alert-recipient ([email protected])

24.2. CREATING A CLUSTER ALERT


The following command creates a cluster alert. The options that you configure are agent-specific
configuration values that are passed to the alert agent script at the path you specify as additional
environment variables. If you do not specify a value for id, one will be generated.

pcs alert create path=path [id=alert-id] [description=description] [options [option=value]...] [meta


[meta-option=value]...]

Multiple alert agents may be configured; the cluster will call all of them for each event. Alert agents will
be called only on cluster nodes. They will be called for events involving Pacemaker Remote nodes, but
they will never be called on those nodes.

The following example creates a simple alert that will call myscript.sh for each event.

# pcs alert create id=my_alert path=/path/to/myscript.sh

24.3. DISPLAYING, MODIFYING, AND REMOVING CLUSTER ALERTS


The following command shows all configured alerts along with the values of the configured options.

pcs alert [config|show]

The following command updates an existing alert with the specified alert-id value.

135
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

pcs alert update alert-id [path=path] [description=description] [options [option=value]...] [meta [meta-
option=value]...]

The following command removes an alert with the specified alert-id value.

pcs alert remove alert-id

Alternately, you can run the pcs alert delete command, which is identical to the pcs alert remove
command. Both the pcs alert delete and the pcs alert remove commands allow you to specify more
than one alert to be deleted.

24.4. CONFIGURING ALERT RECIPIENTS


Usually alerts are directed towards a recipient. Thus each alert may be additionally configured with one
or more recipients. The cluster will call the agent separately for each recipient.

The recipient may be anything the alert agent can recognize: an IP address, an email address, a file
name, or whatever the particular agent supports.

The following command adds a new recipient to the specified alert.

pcs alert recipient add alert-id value=recipient-value [id=recipient-id] [description=description] [options


[option=value]...] [meta [meta-option=value]...]

The following command updates an existing alert recipient.

pcs alert recipient update recipient-id [value=recipient-value] [description=description] [options


[option=value]...] [meta [meta-option=value]...]

The following command removes the specified alert recipient.

pcs alert recipient remove recipient-id

Alternately, you can run the pcs alert recipient delete command, which is identical to the pcs alert
recipient remove command. Both the pcs alert recipient remove and the pcs alert recipient delete
commands allow you to remove more than one alert recipient.

The following example command adds the alert recipient my-alert-recipient with a recipient ID of my-
recipient-id to the alert my-alert. This will configure the cluster to call the alert script that has been
configured for my-alert for each event, passing the recipient some-address as an environment variable.

# pcs alert recipient add my-alert value=my-alert-recipient id=my-recipient-id options


value=some-address

24.5. ALERT META OPTIONS


As with resource agents, meta options can be configured for alert agents to affect how Pacemaker calls
them. Table 24.1, “Alert Meta Options” describes the alert meta options. Meta options can be configured
per alert agent as well as per recipient.

Table 24.1. Alert Meta Options

136
CHAPTER 24. TRIGGERING SCRIPTS FOR CLUSTER EVENTS

Meta-Attribute Default Description

timestamp-format %H:%M:%S.%06N Format the cluster will use when


sending the event’s timestamp to
the agent. This is a string as used
with the date (1) command.

timeout 30s If the alert agent does not


complete within this amount of
time, it will be terminated.

The following example configures an alert that calls the script myscript.sh and then adds two recipients
to the alert. The first recipient has an ID of my-alert-recipient1 and the second recipient has an ID of
my-alert-recipient2. The script will get called twice for each event, with each call using a 15-second
timeout. One call will be passed to the recipient [email protected] with a timestamp in the
format %D %H:%M, while the other call will be passed to the recipient [email protected] with a
timestamp in the format %c.

# pcs alert create id=my-alert path=/path/to/myscript.sh meta timeout=15s


# pcs alert recipient add my-alert [email protected] id=my-alert-recipient1 meta
timestamp-format="%D %H:%M"
# pcs alert recipient add my-alert [email protected] id=my-alert-recipient2 meta
timestamp-format="%c"

24.6. ALERT CONFIGURATION COMMAND EXAMPLES


The following sequential examples show some basic alert configuration commands to show the format
to use to create alerts, add recipients, and display the configured alerts.

Note that while you must install the alert agents themselves on each node in a cluster, you need to run
the pcs commands only once.

The following commands create a simple alert, add two recipients to the alert, and display the configured
values.

Since no alert ID value is specified, the system creates an alert ID value of alert.

The first recipient creation command specifies a recipient of rec_value. Since this command
does not specify a recipient ID, the value of alert-recipient is used as the recipient ID.

The second recipient creation command specifies a recipient of rec_value2. This command
specifies a recipient ID of my-recipient for the recipient.

# pcs alert create path=/my/path


# pcs alert recipient add alert value=rec_value
# pcs alert recipient add alert value=rec_value2 id=my-recipient
# pcs alert config
Alerts:
Alert: alert (path=/my/path)
Recipients:
Recipient: alert-recipient (value=rec_value)
Recipient: my-recipient (value=rec_value2)

137
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

This following commands add a second alert and a recipient for that alert. The alert ID for the second
alert is my-alert and the recipient value is my-other-recipient. Since no recipient ID is specified, the
system provides a recipient id of my-alert-recipient.

# pcs alert create id=my-alert path=/path/to/script description=alert_description options


option1=value1 opt=val meta timeout=50s timestamp-format="%H%B%S"
# pcs alert recipient add my-alert value=my-other-recipient
# pcs alert
Alerts:
Alert: alert (path=/my/path)
Recipients:
Recipient: alert-recipient (value=rec_value)
Recipient: my-recipient (value=rec_value2)
Alert: my-alert (path=/path/to/script)
Description: alert_description
Options: opt=val option1=value1
Meta options: timestamp-format=%H%B%S timeout=50s
Recipients:
Recipient: my-alert-recipient (value=my-other-recipient)

The following commands modify the alert values for the alert my-alert and for the recipient my-alert-
recipient.

# pcs alert update my-alert options option1=newvalue1 meta timestamp-format="%H%M%S"


# pcs alert recipient update my-alert-recipient options option1=new meta timeout=60s
# pcs alert
Alerts:
Alert: alert (path=/my/path)
Recipients:
Recipient: alert-recipient (value=rec_value)
Recipient: my-recipient (value=rec_value2)
Alert: my-alert (path=/path/to/script)
Description: alert_description
Options: opt=val option1=newvalue1
Meta options: timestamp-format=%H%M%S timeout=50s
Recipients:
Recipient: my-alert-recipient (value=my-other-recipient)
Options: option1=new
Meta options: timeout=60s

The following command removes the recipient my-alert-recipient from alert.

# pcs alert recipient remove my-recipient


# pcs alert
Alerts:
Alert: alert (path=/my/path)
Recipients:
Recipient: alert-recipient (value=rec_value)
Alert: my-alert (path=/path/to/script)
Description: alert_description
Options: opt=val option1=newvalue1
Meta options: timestamp-format="%M%B%S" timeout=50s
Recipients:

138
CHAPTER 24. TRIGGERING SCRIPTS FOR CLUSTER EVENTS

Recipient: my-alert-recipient (value=my-other-recipient)


Options: option1=new
Meta options: timeout=60s

The following command removes myalert from the configuration.

# pcs alert remove myalert


# pcs alert
Alerts:
Alert: alert (path=/my/path)
Recipients:
Recipient: alert-recipient (value=rec_value)

24.7. WRITING AN ALERT AGENT


There are three types of Pacemaker alerts: node alerts, fencing alerts, and resource alerts. The
environment variables that are passed to the alert agents can differ, depending on the type of alert.
Table 24.2, “Environment Variables Passed to Alert Agents” describes the environment variables that
are passed to alert agents and specifies when the environment variable is associated with a specific alert
type.

Table 24.2. Environment Variables Passed to Alert Agents

Environment Variable Description

CRM_alert_kind The type of alert (node, fencing, or resource)

CRM_alert_version The version of Pacemaker sending the alert

CRM_alert_recipient The configured recipient

CRM_alert_node_sequence A sequence number increased whenever an alert is being


issued on the local node, which can be used to reference
the order in which alerts have been issued by Pacemaker.
An alert for an event that happened later in time reliably has
a higher sequence number than alerts for earlier events. Be
aware that this number has no cluster-wide meaning.

CRM_alert_timestamp A timestamp created prior to executing the agent, in the


format specified by the timestamp-format meta option.
This allows the agent to have a reliable, high-precision time
of when the event occurred, regardless of when the agent
itself was invoked (which could potentially be delayed due
to system load or other circumstances).

CRM_alert_node Name of affected node

CRM_alert_desc Detail about event. For node alerts, this is the node’s current
state (member or lost). For fencing alerts, this is a summary
of the requested fencing operation, including origin, target,
and fencing operation error code, if any. For resource alerts,
this is a readable string equivalent of CRM_alert_status.

139
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Environment Variable Description

CRM_alert_nodeid ID of node whose status changed (provided with node


alerts only)

CRM_alert_task The requested fencing or resource operation (provided with


fencing and resource alerts only)

CRM_alert_rc The numerical return code of the fencing or resource


operation (provided with fencing and resource alerts only)

CRM_alert_rsc The name of the affected resource (resource alerts only)

CRM_alert_interval The interval of the resource operation (resource alerts only)

CRM_alert_target_rc The expected numerical return code of the operation


(resource alerts only)

CRM_alert_status A numerical code used by Pacemaker to represent the


operation result (resource alerts only)

When writing an alert agent, you must take the following concerns into account.

Alert agents may be called with no recipient (if none is configured), so the agent must be able to
handle this situation, even if it only exits in that case. Users may modify the configuration in
stages, and add a recipient later.

If more than one recipient is configured for an alert, the alert agent will be called once per
recipient. If an agent is not able to run concurrently, it should be configured with only a single
recipient. The agent is free, however, to interpret the recipient as a list.

When a cluster event occurs, all alerts are fired off at the same time as separate processes.
Depending on how many alerts and recipients are configured and on what is done within the
alert agents, a significant load burst may occur. The agent could be written to take this into
consideration, for example by queueing resource-intensive actions into some other instance,
instead of directly executing them.

Alert agents are run as the hacluster user, which has a minimal set of permissions. If an agent
requires additional privileges, it is recommended to configure sudo to allow the agent to run the
necessary commands as another user with the appropriate privileges.

Take care to validate and sanitize user-configured parameters, such as CRM_alert_timestamp


(whose content is specified by the user-configured timestamp-format), CRM_alert_recipient,
and all alert options. This is necessary to protect against configuration errors. In addition, if some
user can modify the CIB without having hacluster-level access to the cluster nodes, this is a
potential security concern as well, and you should avoid the possibility of code injection.

If a cluster contains resources with operations for which the on-fail parameter is set to fence,
there will be multiple fence notifications on failure, one for each resource for which this
parameter is set plus one additional notification. Both the pacemaker-fenced and pacemaker-
controld will send notifications. Pacemaker performs only one actual fence operation in this
case, however, no matter how many notifications are sent.

140
CHAPTER 24. TRIGGERING SCRIPTS FOR CLUSTER EVENTS

NOTE

The alerts interface is designed to be backward compatible with the external scripts
interface used by the ocf:pacemaker:ClusterMon resource. To preserve this
compatibility, the environment variables passed to alert agents are available prepended
with CRM_notify_ as well as CRM_alert_. One break in compatibility is that the
ClusterMon resource ran external scripts as the root user, while alert agents are run as
the hacluster user.

141
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 25. CONFIGURING MULTI-SITE CLUSTERS WITH


PACEMAKER
When a cluster spans more than one site, issues with network connectivity between the sites can lead to
split-brain situations. When connectivity drops, there is no way for a node on one site to determine
whether a node on another site has failed or is still functioning with a failed site interlink. In addition, it
can be problematic to provide high availability services across two sites which are too far apart to keep
synchronous.

To address these issues, Pacemaker provides full support for the ability to configure high availability
clusters that span multiple sites through the use of a Booth cluster ticket manager.

25.1. OVERVIEW OF BOOTH CLUSTER TICKET MANAGER


The Booth ticket manager is a distributed service that is meant to be run on a different physical network
than the networks that connect the cluster nodes at particular sites. It yields another, loose cluster, a
Booth formation, that sits on top of the regular clusters at the sites. This aggregated communication
layer facilitates consensus-based decision processes for individual Booth tickets.

A Booth ticket is a singleton in the Booth formation and represents a time-sensitive, movable unit of
authorization. Resources can be configured to require a certain ticket to run. This can ensure that
resources are run at only one site at a time, for which a ticket or tickets have been granted.

You can think of a Booth formation as an overlay cluster consisting of clusters running at different sites,
where all the original clusters are independent of each other. It is the Booth service which communicates
to the clusters whether they have been granted a ticket, and it is Pacemaker that determines. whether
to run resources in a cluster based on a Pacemaker ticket constraint. This means that when using the
ticket manager, each of the clusters can run its own resources as well as shared resources. For example
there can be resources A, B and C running only in one cluster, resources D, E, and F running only in the
other cluster, and resources G and H running in either of the two clusters as determined by a ticket. It is
also possible to have an additional resource J that could run in either of the two clusters as determined
by a separate ticket.

25.2. CONFIGURING MULTI-SITE CLUSTERS WITH PACEMAKER


The following procedure provides an outline of the steps you follow to configure a multi-site
configuration that uses the Booth ticket manager.

These example commands use the following arrangement:

Cluster 1 consists of the nodes cluster1-node1 and cluster1-node2

Cluster 1 has a floating IP address assigned to it of 192.168.11.100

Cluster 2 consists of cluster2-node1 and cluster2-node2

Cluster 2 has a floating IP address assigned to it of 192.168.22.100

The arbitrator node is arbitrator-node with an ip address of 192.168.99.100

The name of the Booth ticket that this configuration uses is apacheticket

These example commands assume that the cluster resources for an Apache service have been
configured as part of the resource group apachegroup for each cluster. It is not required that the
resources and resource groups be the same on each cluster to configure a ticket constraint for those

142
CHAPTER 25. CONFIGURING MULTI-SITE CLUSTERS WITH PACEMAKER

resources, since the Pacemaker instance for each cluster is independent, but that is a common failover
scenario.

Note that at any time in the configuration procedure you can enter the pcs booth config command to
display the booth configuration for the current node or cluster or the pcs booth status command to
display the current status of booth on the local node.

1. Install the booth-site Booth ticket manager package on each node of both clusters.

[root@cluster1-node1 ~]# yum install -y booth-site


[root@cluster1-node2 ~]# yum install -y booth-site
[root@cluster2-node1 ~]# yum install -y booth-site
[root@cluster2-node2 ~]# yum install -y booth-site

2. Install the pcs, booth-core, and booth-arbitrator packages on the arbitrator node.

[root@arbitrator-node ~]# yum install -y pcs booth-core booth-arbitrator

3. Ensure that ports 9929/tcp and 9929/udp are open on all cluster nodes and on the arbitrator
node.
For example, running the following commands on all nodes in both clusters as well as on the
arbitrator node allows access to ports 9929/tcp and 9929/udp on those nodes.

# firewall-cmd --add-port=9929/udp
# firewall-cmd --add-port=9929/tcp
# firewall-cmd --add-port=9929/udp --permanent
# firewall-cmd --add-port=9929/tcp --permanent

Note that this procedure in itself allows any machine anywhere to access port 9929 on the
nodes. You should ensure that on your site the nodes are open only to the nodes that require
them.

4. Create a Booth configuration on one node of one cluster. The addresses you specify for each
cluster and for the arbitrator must be IP addresses. For each cluster, you specify a floating IP
address.

[cluster1-node1 ~] # pcs booth setup sites 192.168.11.100 192.168.22.100 arbitrators


192.168.99.100

This command creates the configuration files /etc/booth/booth.conf and /etc/booth/booth.key


on the node from which it is run.

5. Create a ticket for the Booth configuration. This is the ticket that you will use to define the
resource constraint that will allow resources to run only when this ticket has been granted to the
cluster.
This basic failover configuration procedure uses only one ticket, but you can create additional
tickets for more complicated scenarios where each ticket is associated with a different resource
or resources.

[cluster1-node1 ~] # pcs booth ticket add apacheticket

6. Synchronize the Booth configuration to all nodes in the current cluster.

[cluster1-node1 ~] # pcs booth sync

143
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

7. From the arbitrator node, pull the Booth configuration to the arbitrator. If you have not
previously done so, you must first authenticate pcs to the node from which you are pulling the
configuration.

[arbitrator-node ~] # pcs cluster auth cluster1-node1


[arbitrator-node ~] # pcs booth pull cluster1-node1

8. Pull the Booth configuration to the other cluster and synchronize to all the nodes of that cluster.
As with the arbitrator node, if you have not previously done so, you must first authenticate pcs
to the node from which you are pulling the configuration.

[cluster2-node1 ~] # pcs cluster auth cluster1-node1


[cluster2-node1 ~] # pcs booth pull cluster1-node1
[cluster2-node1 ~] # pcs booth sync

9. Start and enable Booth on the arbitrator.

NOTE

You must not manually start or enable Booth on any of the nodes of the clusters
since Booth runs as a Pacemaker resource in those clusters.

[arbitrator-node ~] # pcs booth start


[arbitrator-node ~] # pcs booth enable

10. Configure Booth to run as a cluster resource on both cluster sites. This creates a resource
group with booth-ip and booth-service as members of that group.

[cluster1-node1 ~] # pcs booth create ip 192.168.11.100


[cluster2-node1 ~] # pcs booth create ip 192.168.22.100

11. Add a ticket constraint to the resource group you have defined for each cluster.

[cluster1-node1 ~] # pcs constraint ticket add apacheticket apachegroup


[cluster2-node1 ~] # pcs constraint ticket add apacheticket apachegroup

You can enter the following command to display the currently configured ticket constraints.

pcs constraint ticket [show]

12. Grant the ticket you created for this setup to the first cluster.
Note that it is not necessary to have defined ticket constraints before granting a ticket. Once
you have initially granted a ticket to a cluster, then Booth takes over ticket management unless
you override this manually with the pcs booth ticket revoke command. For information on the
pcs booth administration commands, see the PCS help screen for the pcs booth command.

[cluster1-node1 ~] # pcs booth ticket grant apacheticket

It is possible to add or remove tickets at any time, even after completing this procedure. After adding or
removing a ticket, however, you must synchronize the configuration files to the other nodes and clusters
as well as to the arbitrator and grant the ticket as is shown in this procedure.

144
CHAPTER 25. CONFIGURING MULTI-SITE CLUSTERS WITH PACEMAKER

For information on additional Booth administration commands that you can use for cleaning up and
removing Booth configuration files, tickets, and resources, see the PCS help screen for the pcs booth
command.

145
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 26. INTEGRATING NON-COROSYNC NODES INTO A


CLUSTER: THE PACEMAKER_REMOTE SERVICE
The pacemaker_remote service allows nodes not running corosync to integrate into the cluster and
have the cluster manage their resources just as if they were real cluster nodes.

Among the capabilities that the pacemaker_remote service provides are the following:

The pacemaker_remote service allows you to scale beyond the Red Hat support limit of 32
nodes for RHEL 8.1.

The pacemaker_remote service allows you to manage a virtual environment as a cluster


resource and also to manage individual services within the virtual environment as cluster
resources.

The following terms are used to describe the pacemaker_remote service.

cluster node — A node running the High Availability services ( pacemaker and corosync).

remote node — A node running pacemaker_remote to remotely integrate into the cluster
without requiring corosync cluster membership. A remote node is configured as a cluster
resource that uses the ocf:pacemaker:remote resource agent.

guest node — A virtual guest node running the pacemaker_remote service. The virtual guest
resource is managed by the cluster; it is both started by the cluster and integrated into the
cluster as a remote node.

pacemaker_remote — A service daemon capable of performing remote application management


within remote nodes and KVM guest nodes in a Pacemaker cluster environment. This service is
an enhanced version of Pacemaker’s local executor daemon (pacemaker-execd) that is
capable of managing resources remotely on a node not running corosync.

A Pacemaker cluster running the pacemaker_remote service has the following characteristics.

Remote nodes and guest nodes run the pacemaker_remote service (with very little
configuration required on the virtual machine side).

The cluster stack (pacemaker and corosync), running on the cluster nodes, connects to the
pacemaker_remote service on the remote nodes, allowing them to integrate into the cluster.

The cluster stack (pacemaker and corosync), running on the cluster nodes, launches the guest
nodes and immediately connects to the pacemaker_remote service on the guest nodes,
allowing them to integrate into the cluster.

The key difference between the cluster nodes and the remote and guest nodes that the cluster nodes
manage is that the remote and guest nodes are not running the cluster stack. This means the remote
and guest nodes have the following limitations:

they do not take place in quorum

they do not execute fencing device actions

they are not eligible to be the cluster’s Designated Controller (DC)

they do not themselves run the full range of pcs commands

On the other hand, remote nodes and guest nodes are not bound to the scalability limits associated with
146
CHAPTER 26. INTEGRATING NON-COROSYNC NODES INTO A CLUSTER: THE PACEMAKER_REMOTE SERVICE

On the other hand, remote nodes and guest nodes are not bound to the scalability limits associated with
the cluster stack.

Other than these noted limitations, the remote and guest nodes behave just like cluster nodes in
respect to resource management, and the remote and guest nodes can themselves be fenced. The
cluster is fully capable of managing and monitoring resources on each remote and guest node: You can
build constraints against them, put them in standby, or perform any other action you perform on cluster
nodes with the pcs commands. Remote and guest nodes appear in cluster status output just as cluster
nodes do.

26.1. HOST AND GUEST AUTHENTICATION OF PACEMAKER_REMOTE


NODES
The connection between cluster nodes and pacemaker_remote is secured using Transport Layer
Security (TLS) with pre-shared key (PSK) encryption and authentication over TCP (using port 3121 by
default). This means both the cluster node and the node running pacemaker_remote must share the
same private key. By default this key must be placed at /etc/pacemaker/authkey on both cluster nodes
and remote nodes.

The pcs cluster node add-guest command sets up the authkey for guest nodes and the pcs cluster
node add-remote command sets up the authkey for remote nodes.

26.2. CONFIGURING KVM GUEST NODES


A Pacemaker guest node is a virtual guest node running the pacemaker_remote service. The virtual
guest node is managed by the cluster.

26.2.1. Guest node resource options


When configuring a virtual machine to act as a guest node, you create a VirtualDomain resource, which
manages the virtual machine. For descriptions of the options you can set for a VirtualDomain resource,
see Table 22.1, “Resource Options for Virtual Domain Resources”.

In addition to the VirtualDomain resource options, metadata options define the resource as a guest
node and define the connection parameters. You set these resource options with the pcs cluster node
add-guest command. Table 26.1, “Metadata Options for Configuring KVM Resources as Remote Nodes”
describes these metadata options.

Table 26.1. Metadata Options for Configuring KVM Resources as Remote Nodes

Field Default Description

remote-node <none> The name of the guest node this


resource defines. This both
enables the resource as a guest
node and defines the unique
name used to identify the guest
node. WARNING: This value
cannot overlap with any resource
or node IDs.

147
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

Field Default Description

remote-port 3121 Configures a custom port to use


for the guest connection to
pacemaker_remote

remote-addr The address provided in the pcs The IP address or host name to
host auth command connect to

remote-connect-timeout 60s Amount of time before a pending


guest connection will time out

26.2.2. Integrating a virtual machine as a guest node


The following procedure is a high-level summary overview of the steps to perform to have Pacemaker
launch a virtual machine and to integrate that machine as a guest node, using libvirt and KVM virtual
guests.

1. Configure the VirtualDomain resources.

2. Enter the following commands on every virtual machine to install pacemaker_remote packages,
start the pcsd service and enable it to run on startup, and allow TCP port 3121 through the
firewall.

# yum install pacemaker-remote resource-agents pcs


# systemctl start pcsd.service
# systemctl enable pcsd.service
# firewall-cmd --add-port 3121/tcp --permanent
# firewall-cmd --add-port 2224/tcp --permanent
# firewall-cmd --reload

3. Give each virtual machine a static network address and unique host name, which should be
known to all nodes. For information on setting a static IP address for the guest virtual machine,
see the Virtualization Deployment and Administration Guide.

4. If you have not already done so, authenticate pcs to the node you will be integrating as a quest
node.

# pcs host auth nodename

5. Use the following command to convert an existing VirtualDomain resource into a guest node.
This command must be run on a cluster node and not on the guest node which is being added. In
addition to converting the resource, this command copies the /etc/pacemaker/authkey to the
guest node and starts and enables the pacemaker_remote daemon on the guest node. The
node name for the guest node, which you can define arbitrarily, can differ from the host name
for the node.

# pcs cluster node add-guest nodename resource_id [options]

6. After creating the VirtualDomain resource, you can treat the guest node just as you would treat
any other node in the cluster. For example, you can create a resource and place a resource
constraint on the resource to run on the guest node as in the following commands, which are run

148
CHAPTER 26. INTEGRATING NON-COROSYNC NODES INTO A CLUSTER: THE PACEMAKER_REMOTE SERVICE

from a cluster node. You can include guest nodes in groups, which allows you to group a storage
device, file system, and VM.

# pcs resource create webserver apache configfile=/etc/httpd/conf/httpd.conf op


monitor interval=30s
# pcs constraint location webserver prefers nodename

26.3. CONFIGURING PACEMAKER REMOTE NODES


A remote node is defined as a cluster resource with ocf:pacemaker:remote as the resource agent. You
create this resource with the pcs cluster node add-remote command.

26.3.1. Remote node resource options


Table 26.2, “Resource Options for Remote Nodes” describes the resource options you can configure for
a remote resource.

Table 26.2. Resource Options for Remote Nodes

Field Default Description

reconnect_interval 0 Time in seconds to wait before


attempting to reconnect to a remote
node after an active connection to the
remote node has been severed. This
wait is recurring. If reconnect fails after
the wait period, a new reconnect
attempt will be made after observing
the wait time. When this option is in
use, Pacemaker will keep attempting to
reach out and connect to the remote
node indefinitely after each wait
interval.

server Address specified with Server to connect to. This can be an IP


pcs host auth address or host name.
command

port TCP port to connect to.

26.3.2. Remote node configuration overview


This section provides a high-level summary overview of the steps to perform to configure a Pacemaker
Remote node and to integrate that node into an existing Pacemaker cluster environment.

1. On the node that you will be configuring as a remote node, allow cluster-related services
through the local firewall.

# firewall-cmd --permanent --add-service=high-availability


success
# firewall-cmd --reload
success

149
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

NOTE

If you are using iptables directly, or some other firewall solution besides
firewalld, simply open the following ports: TCP ports 2224 and 3121.

2. Install the pacemaker_remote daemon on the remote node.

# yum install -y pacemaker-remote resource-agents pcs

3. Start and enable pcsd on the remote node.

# systemctl start pcsd.service


# systemctl enable pcsd.service

4. If you have not already done so, authenticate pcs to the node you will be adding as a remote
node.

# pcs host auth remote1

5. Add the remote node resource to the cluster with the following command. This command also
syncs all relevant configuration files to the new node, starts the node, and configures it to start
pacemaker_remote on boot. This command must be run on a cluster node and not on the
remote node which is being added.

# pcs cluster node add-remote remote1

6. After adding the remote resource to the cluster, you can treat the remote node just as you
would treat any other node in the cluster. For example, you can create a resource and place a
resource constraint on the resource to run on the remote node as in the following commands,
which are run from a cluster node.

# pcs resource create webserver apache configfile=/etc/httpd/conf/httpd.conf op


monitor interval=30s
# pcs constraint location webserver prefers remote1


WARNING

Never involve a remote node connection resource in a resource group,


colocation constraint, or order constraint.

7. Configure fencing resources for the remote node. Remote nodes are fenced the same way as
cluster nodes. Configure fencing resources for use with remote nodes the same as you would
with cluster nodes. Note, however, that remote nodes can never initiate a fencing action. Only
cluster nodes are capable of actually executing a fencing operation against another node.

26.4. CHANGING THE DEFAULT PORT LOCATION

If you need to change the default port location for either Pacemaker or pacemaker_remote, you can

150
CHAPTER 26. INTEGRATING NON-COROSYNC NODES INTO A CLUSTER: THE PACEMAKER_REMOTE SERVICE

If you need to change the default port location for either Pacemaker or pacemaker_remote, you can
set the PCMK_remote_port environment variable that affects both of these daemons. This
environment variable can be enabled by placing it in the /etc/sysconfig/pacemaker file as follows.

====# Pacemaker Remote


...
#
# Specify a custom port for Pacemaker Remote connections
PCMK_remote_port=3121

When changing the default port used by a particular guest node or remote node, the
PCMK_remote_port variable must be set in that node’s /etc/sysconfig/pacemaker file, and the cluster
resource creating the guest node or remote node connection must also be configured with the same
port number (using the remote-port metadata option for guest nodes, or the port option for remote
nodes).

26.5. UPGRADING SYSTEMS WITH PACEMAKER_REMOTE NODES


If the pacemaker_remote service is stopped on an active Pacemaker Remote node, the cluster will
gracefully migrate resources off the node before stopping the node. This allows you to perform
software upgrades and other routine maintenance procedures without removing the node from the
cluster. Once pacemaker_remote is shut down, however, the cluster will immediately try to reconnect. If
pacemaker_remote is not restarted within the resource’s monitor timeout, the cluster will consider the
monitor operation as failed.

If you wish to avoid monitor failures when the pacemaker_remote service is stopped on an active
Pacemaker Remote node, you can use the following procedure to take the node out of the cluster
before performing any system administration that might stop pacemaker_remote

1. Stop the node’s connection resource with the pcs resource disable resourcename, which will
move all services off the node. For guest nodes, this will also stop the VM, so the VM must be
started outside the cluster (for example, using virsh) to perform any maintenance.

2. Perform the required maintenance.

3. When ready to return the node to the cluster, re-enable the resource with the pcs resource
enable.

151
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

CHAPTER 27. PERFORMING CLUSTER MAINTENANCE


In order to perform maintenance on the nodes of your cluster, you may need to stop or move the
resources and services running on that cluster. Or you may need to stop the cluster software while
leaving the services untouched. Pacemaker provides a variety of methods for performing system
maintenance.

If you need to stop a node in a cluster while continuing to provide the services running on that
cluster on another node, you can put the cluster node in standby mode. A node that is in
standby mode is no longer able to host resources. Any resource currently active on the node will
be moved to another node, or stopped if no other node is eligible to run the resource. For
information on standby mode, see Putting a node into standby mode .

If you need to move an individual resource off the node on which it is currently running without
stopping that resource, you can use the pcs resource move command to move the resource to
a different node. For information on the pcs resource move command, see Manually moving
cluster resources.
When you execute the pcs resource move command, this adds a constraint to the resource to
prevent it from running on the node on which it is currently running. When you are ready to move
the resource back, you can execute the pcs resource clear or the pcs constraint delete
command to remove the constraint. This does not necessarily move the resources back to the
original node, however, since where the resources can run at that point depends on how you
have configured your resources initially. You can relocate a resource to its preferred node with
the pcs resource relocate run command, as described in Moving a resource to its preferred
node.

If you need to stop a running resource entirely and prevent the cluster from starting it again, you
can use the pcs resource disable command. For information on the pcs resource disable
command, see Enabling, disabling, and banning cluster resources .

If you want to prevent Pacemaker from taking any action for a resource (for example, if you
want to disable recovery actions while performing maintenance on the resource, or if you need
to reload the /etc/sysconfig/pacemaker settings), use the pcs resource unmanage
command, as described in Setting a resource to unmanaged mode . Pacemaker Remote
connection resources should never be unmanaged.

If you need to put the cluster in a state where no services will be started or stopped, you can set
the maintenance-mode cluster property. Putting the cluster into maintenance mode
automatically unmanages all resources. For information on putting the cluster in maintenance
mode, see Putting a cluster in maintenance mode .

If you need to update the packages that make up the RHEL High Availability and Resilient
Storage Add-Ons, you can update the packages on one node at a time or on the entire cluster
as a whole, as summarized in Updating a Red Hat Enterprise Linux high availability cluster .

If you need to perform maintenance on a Pacemaker remote node, you can remove that node
from the cluster by disabling the remote node resource, as described in Upgrading remote
nodes and guest nodes.

27.1. PUTTING A NODE INTO STANDBY MODE


When a cluster node is in standby mode, the node is no longer able to host resources. Any resources
currently active on the node will be moved to another node.

The following command puts the specified node into standby mode. If you specify the --all, this
command puts all nodes into standby mode.

152
CHAPTER 27. PERFORMING CLUSTER MAINTENANCE

You can use this command when updating a resource’s packages. You can also use this command when
testing a configuration, to simulate recovery without actually shutting down a node.

pcs node standby node | --all

The following command removes the specified node from standby mode. After running this command,
the specified node is then able to host resources. If you specify the --all, this command removes all
nodes from standby mode.

pcs node unstandby node | --all

Note that when you execute the pcs node standby command, this prevents resources from running on
the indicated node. When you execute the pcs node unstandby command, this allows resources to run
on the indicated node. This does not necessarily move the resources back to the indicated node; where
the resources can run at that point depends on how you have configured your resources initially.

27.2. MANUALLY MOVING CLUSTER RESOURCES


You can override the cluster and force resources to move from their current location. There are two
occasions when you would want to do this:

When a node is under maintenance, and you need to move all resources running on that node to
a different node

When individually specified resources needs to be moved

To move all resources running on a node to a different node, you put the node in standby mode.

You can move individually specified resources in either of the following ways.

You can use the pcs resource move command to move a resource off a node on which it is
currently running.

You can use the pcs resource relocate run command to move a resource to its preferred
node, as determined by current cluster status, constraints, location of resources and other
settings.

27.2.1. Moving a resource from its current node


To move a resource off the node on which it is currently running, use the following command, specifying
the resource_id of the resource as defined. Specify the destination_node if you want to indicate on
which node to run the resource that you are moving.

pcs resource move resource_id [destination_node] [--master] [lifetime=lifetime]

NOTE

When you execute the pcs resource move command, this adds a constraint to the
resource to prevent it from running on the node on which it is currently running. You can
execute the pcs resource clear or the pcs constraint delete command to remove the
constraint. This does not necessarily move the resources back to the original node; where
the resources can run at that point depends on how you have configured your resources
initially.

153
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

If you specify the --master parameter of the pcs resource move command, the scope of the constraint
is limited to the master role and you must specify master_id rather than resource_id.

You can optionally configure a lifetime parameter for the pcs resource move command to indicate a
period of time the constraint should remain. You specify the units of a lifetime parameter according to
the format defined in ISO 8601, which requires that you specify the unit as a capital letter such as Y (for
years), M (for months), W (for weeks), D (for days), H (for hours), M (for minutes), and S (for seconds).

To distinguish a unit of minutes(M) from a unit of months(M), you must specify PT before indicating the
value in minutes. For example, a lifetime parameter of 5M indicates an interval of five months, while a
lifetime parameter of PT5M indicates an interval of five minutes.

The lifetime parameter is checked at intervals defined by the cluster-recheck-interval cluster property.
By default this value is 15 minutes. If your configuration requires that you check this parameter more
frequently, you can reset this value with the following command.

pcs property set cluster-recheck-interval=value

You can optionally configure a --wait[=n] parameter for the pcs resource move command to indicate
the number of seconds to wait for the resource to start on the destination node before returning 0 if
the resource is started or 1 if the resource has not yet started. If you do not specify n, the default
resource timeout will be used.

The following command moves the resource resource1 to node example-node2 and prevents it from
moving back to the node on which it was originally running for one hour and thirty minutes.

pcs resource move resource1 example-node2 lifetime=PT1H30M

The following command moves the resource resource1 to node example-node2 and prevents it from
moving back to the node on which it was originally running for thirty minutes.

pcs resource move resource1 example-node2 lifetime=PT30M

27.2.2. Moving a resource to its preferred node


After a resource has moved, either due to a failover or to an administrator manually moving the node, it
will not necessarily move back to its original node even after the circumstances that caused the failover
have been corrected. To relocate resources to their preferred node, use the following command. A
preferred node is determined by the current cluster status, constraints, resource location, and other
settings and may change over time.

pcs resource relocate run [resource1] [resource2] ...

If you do not specify any resources, all resource are relocated to their preferred nodes.

This command calculates the preferred node for each resource while ignoring resource stickiness. After
calculating the preferred node, it creates location constraints which will cause the resources to move to
their preferred nodes. Once the resources have been moved, the constraints are deleted automatically.
To remove all constraints created by the pcs resource relocate run command, you can enter the pcs
resource relocate clear command. To display the current status of resources and their optimal node
ignoring resource stickiness, enter the pcs resource relocate show command.

27.3. ENABLING, DISABLING, AND BANNING CLUSTER RESOURCES

154
CHAPTER 27. PERFORMING CLUSTER MAINTENANCE

In addition to the pcs resource move and pcs resource relocate commands, there are a variety of
other commands you can use to control the behavior of cluster resources.

You can manually stop a running resource and prevent the cluster from starting it again with the
following command. Depending on the rest of the configuration (constraints, options, failures, and so
on), the resource may remain started. If you specify the --wait option, pcs will wait up to 'n' seconds for
the resource to stop and then return 0 if the resource is stopped or 1 if the resource has not stopped. If
'n' is not specified it defaults to 60 minutes.

pcs resource disable resource_id [--wait[=n]]

You can use the following command to allow the cluster to start a resource. Depending on the rest of
the configuration, the resource may remain stopped. If you specify the --wait option, pcs will wait up to
'n' seconds for the resource to start and then return 0 if the resource is started or 1 if the resource has
not started. If 'n' is not specified it defaults to 60 minutes.

pcs resource enable resource_id [--wait[=n]]

Use the following command to prevent a resource from running on a specified node, or on the current
node if no node is specified.

pcs resource ban resource_id [node] [--master] [lifetime=lifetime] [--wait[=n]]

Note that when you execute the pcs resource ban command, this adds a -INFINITY location constraint
to the resource to prevent it from running on the indicated node. You can execute the pcs resource
clear or the pcs constraint delete command to remove the constraint. This does not necessarily move
the resources back to the indicated node; where the resources can run at that point depends on how
you have configured your resources initially.

If you specify the --master parameter of the pcs resource ban command, the scope of the constraint
is limited to the master role and you must specify master_id rather than resource_id.

You can optionally configure a lifetime parameter for the pcs resource ban command to indicate a
period of time the constraint should remain.

You can optionally configure a --wait[=n] parameter for the pcs resource ban command to indicate
the number of seconds to wait for the resource to start on the destination node before returning 0 if
the resource is started or 1 if the resource has not yet started. If you do not specify n, the default
resource timeout will be used.

You can use the debug-start parameter of the pcs resource command to force a specified resource to
start on the current node, ignoring the cluster recommendations and printing the output from starting
the resource. This is mainly used for debugging resources; starting resources on a cluster is (almost)
always done by Pacemaker and not directly with a pcs command. If your resource is not starting, it is
usually due to either a misconfiguration of the resource (which you debug in the system log), constraints
that prevent the resource from starting, or the resource being disabled. You can use this command to
test resource configuration, but it should not normally be used to start resources in a cluster.

The format of the debug-start command is as follows.

pcs resource debug-start resource_id

27.4. SETTING A RESOURCE TO UNMANAGED MODE

When a resource is in unmanaged mode, the resource is still in the configuration but Pacemaker does
155
Red Hat Enterprise Linux 8 Configuring and managing high availability clusters

When a resource is in unmanaged mode, the resource is still in the configuration but Pacemaker does
not manage the resource.

The following command sets the indicated resources to unmanaged mode.

pcs resource unmanage resource1 [resource2] ...

The following command sets resources to managed mode, which is the default state.

pcs resource manage resource1 [resource2] ...

You can specify the name of a resource group with the pcs resource manage or pcs resource
unmanage command. The command will act on all of the resources in the group, so that you can set all
of the resources in a group to managed or unmanaged mode with a single command and then manage
the contained resources individually.

27.5. PUTTING A CLUSTER IN MAINTENANCE MODE


When a cluster is in maintenance mode, the cluster does not start or stop any services until told
otherwise. When maintenance mode is completed, the cluster does a sanity check of the current state of
any services, and then stops or starts any that need it.

To put a cluster in maintenance mode, use the following command to set the maintenance-mode
cluster property to true.

# pcs property set maintenance-mode=true

To remove a cluster from maintenance mode, use the following command to set the maintenance-
mode cluster property to false.

# pcs property set maintenance-mode=false

u can remove a cluster property from the configuration with the following command.

pcs property unset property

Alternately, you can remove a cluster property from a configuration by leaving the value field of the pcs
property set command blank. This restores that property to its default value. For example, if you have
previously set the symmetric-cluster property to false, the following command removes the value you
have set from the configuration and restores the value of symmetric-cluster to true, which is its default
value.

# pcs property set symmetric-cluster=

27.6. UPDATING A RHEL HIGH AVAILABILITY CLUSTER


Updating packages that make up the RHEL High Availability and Resilient Storage Add-Ons, either
individually or as a whole, can be done in one of two general ways:

Rolling Updates: Remove one node at a time from service, update its software, then integrate it
back into the cluster. This allows the cluster to continue providing service and managing
resources while each node is updated.

156
CHAPTER 27. PERFORMING CLUSTER MAINTENANCE

Entire Cluster Update : Stop the entire cluster, apply updates to all nodes, then start the cluster
back up.


WARNING

It is critical that when performing software update procedures for Red Hat
Enterprise LInux High Availability and Resilient Storage clusters, you ensure that any
node that will undergo updates is not an active member of the cluster before those
updates are initiated.

For a full description of each of these methods and the procedures to follow for the updates, see
Recommended Practices for Applying Software Updates to a RHEL High Availability or Resilient Storage
Cluster.

27.7. UPGRADING REMOTE NODES AND GUEST NODES


If the pacemaker_remote service is stopped on an active remote node or guest node, the cluster will
gracefully migrate resources off the node before stopping the node. This allows you to perform
software upgrades and other routine maintenance procedures without removing the node from the
cluster. Once pacemaker_remote is shut down, however, the cluster will immediately try to reconnect. If
pacemaker_remote is not restarted within the resource’s monitor timeout, the cluster will consider the
monitor operation as failed.

If you wish to avoid monitor failures when the pacemaker_remote service is stopped on an active
Pacemaker Remote node, you can use the following procedure to take the node out of the cluster
before performing any system administration that might stop pacemaker_remote

1. Stop the node’s connection resource with the pcs resource disable resourcename, which will
move all services off the node. For guest nodes, this will also stop the VM, so the VM must be
started outside the cluster (for example, using virsh) to perform any maintenance.

2. Perform the required maintenance.

3. When ready to return the node to the cluster, re-enable the resource with the pcs resource
enable.