ENERIUM ®
Multi-energy
power monitors
Functions
Simple, intuitive and customizable interface for quick access to the information that you need.
Preventive maintenance
Q Installation operating time
Q Operating time of monitored equipment
Quick programming
Q Current transformer ratios and communication parameters can
be set on the front panel or remotely
Alarms
Q Possibility of protection by password
Q 16 programmable alarms on
instantaneous, average, min
and max values, as well as Customizable screens
analogue and on-off inputs
(e.g. circuit-breaker status) Q 3 screens with 4 display lines each to organize the information
as you wish
Q Recording of the last 64
events (values, dates, times,
durations)
Q Flashing display if there is an
Harmonic analysis
alarm Q Measurement of THD per phase
on U, I and In
Q Spectral analysis per phase up
to the 50th order on U, I and In
Graphics for easier data analysis
Qualimetry
Validation
and navigation keys
via drop-down menus
2 3
Multiple applications
In addition to the generic functions of power monitors, the ENERIUM range also offers extensive,
customizable communication functions.
ANALOGUE INPUTS METERING INPUTS SYNCHRO PULSE INPUTS STORAGE OF STATUSES AND ALARMS
E.ONLINE® ENERGY
CURRENT AND VOLTAGE INPUTS – LV/MV/HV NETWORKS MANAGEMENT SOFTWARE
Inputs
Communication
Outputs
4 5
Choose your power monitor and related software
ENERIUM®, THE TECHNOLOGICAL REFERENCE for everything from basic applications (secondary
switchboard, load monitoring) to the most demanding tasks (metering station).
ENERIUM 30 ENERIUM 50 ENERIUM 150 ENERIUM 100 ENERIUM 200 ENERIUM 300
Architecture:
A Energy management :
ELECTRICAL ENERGY MULTI-ENERGY QUALIMETRY
installation's architecture >
Accuracy class (IEC61557-12) 1 0.5 0.5 0.5 0.5 ou 0.2 0.2
Format
consumption with
96 x 96 mm 96 x 96 mm 96 x 96 mm 144 x 144 mm 144 x 144 mm 144 x 144 mm
Graphic LCD screen O O O O O O
temperature curves
Version without display – – – Enerium 110 Enerium 210 Enerium 310
Flush-mounted, Flush-mounted, Flush-mounted, Flush-mounted, Flush-mounted, Flush-mounted,
Mounting DIN rail* DIN rail* or DIN rail* or
DIN rail* or DIN rail* or DIN rail* or
plate-mounted* plate-mounted* plate-mounted* or plate-mounted* plate-mounted* plate-mounted*
(Enerium 110) (Enerium 210) (Enerium 310)
Harmonics Display :
D
Max. order –
Installation monitoring :
25 50 25 50 50
Recording functions
managed by the power parameters
8 load curves – O O – O O
O O O
monitor
4 trend curves – – 1
Alarms ! ! after triggering by alarm
Number of alarms 2 16 16 16 16 16
min and max values with
Time/date-stamped events recorded – 64 64 64 64 64 time/date-stamping
Qualimetry functions
Qualimetry according to EN50160 – – – – – O
Metrological LED – – – O O O
Other functions
Programming on front panel O O O O O O
6 7
Functions
Measurements Trend curves
(except on Enerium 30/50)
Alarms
1S min max average min average max average
1S VALUES 1S VALUES
V, U O O O
V, Vearth O V1, V2, V3 O
Vearth O Vearth
U12, U23, U31
I O O O O
I1, I2, I3, In O U12, U23, U31
In (calculated or measured)(1) O O O O I1,I2, I3, In O
Pt
P (4 quadrants) O Qt O Pt O
Pt (4 quadrants) O O O O St O Qt O
Q (4 quadrants) O PFt O St O
O O O U unbalance O PFt O
Qt (4 quadrants)
S O THD V, U, I, In O CosMt
Analogue inputs TanMt O
St O O O O O
(Enerium 100/200 only) Frequency O
FP (4 quadrants) O
AVERAGE VALUES U unbalance
FPt (4 quadrants) O O
V1, V2, V3 O THD V, U, I, In
CosM(4 quadrants) 3 hour meters :
U12, U23, U31 O
CosMt(4 quadrants) O network presence, on-load presence, aux. source
I1, I2, I3, In
TanMt(4 quadrants) O O Analogue inputs (Enerium 100/200 only)
Gen : P1, P2, P3, Pt O
Frequency O O O AVERAGE VALUES
Rec : P1, P2, P3, Pt
V crest factor Analogue inputs Pt Gen, Pt Rec
O
I crest factor (Enerium 100/200 only) Qt Gen, Qt Rec
U unbalance Gen : PF1, PF2, PF3, PFt O St
Harmonics on V, U, I Rec : PF1, PF2, PF3, PFt O TanMt (except on Enerium 30/50/150)
Harmonics on In Gen : CosƵ1, CosƵ2, CosƵ3, CosƵt O Analogue inputs (Enerium 100/200 only)
Rec : CosƵ1, CosƵ2, CosƵ3, CosƵt O ON-OFF INPUTS (Enerium 100/200 only) O
THD V, U, I O O
TanMt O
THD In O O Except Enerium 30
Frequency O
Active energy (receiver, generator)
Reactive energy (Qcad1, 2, 3, 4)
O
O
Crest factor V1, V2, V3
Crest factor I1, I2, I3
O
O
Analogue outputs (option)
Apparent energy (receiver, generator) O
THD U12, U23, U31 O (Except Enerium 30)
On-off input (pulse mode) THD I1, I2, I3, Ineutral O
Analogue input (Enerium 100/200) THD V1, V2, V3 O
1S VALUES
V1, V2, V3, Vearth O
Voltage presence hour meter (U)
U12, U23, U31 O
Load hour meter (I) O
Ph
N
Accessories Frequency O
Unbalanced 3-phase, 4 wires - 3 CTs Unbalanced 3-phase, 4 wires - 4 CTs Unbalanced 3-phase, 3 wires - 3 CTs Unbalanced 3-phase, 3 wires - 2 CTs
Except on Enerium 30/50/150
Dimensions
ENERIUM 30/50/150 ENERIUM 100/200/300 ENERIUM 110/210/310
Example of connection to VT
1R
2S
3T
NN
IN+ IN- I1+ I1- I2+ I2- I3+ I3- VT N V1 V2 V3 Aux Aux
8 9
ENERIUM 30 ENERIUM 50/150 ENERIUM 100/200 ENERIUM 200 ENERIUM 300 ENERIUM 30 ENERIUM 50/150 ENERIUM 100/200 ENERIUM 200 ENERIUM 300
Class 1 Class 0.5 s Class 0.5 s Class 0.2 s Class 0.2 s Class 1 Class 0.5 s Class 0.5 s Class 0.2 s Class 0.2 s
Active energy Class 0.5 s Active energy Class 0.2 s Power consumption - - < 50 mW
EN62053-22 Active energy Class 1
Active energy Class 0.2 s
Reactive energy Class 2 Input impedance - - 50 Ω
Active energy Class 0.5 s
Storage
Active power and energy 1 % for 5 % In ≤ I ≤ Imax 0.5 % for 5 % In ≤ I ≤ Imax 0.2 % for 5 % In ≤ I ≤ Imax
Non-volatile memory Configuration parameters – Recordings (curves, alarms, min-max, qualimetry events log, IEC 50160 statistics)
Reactive power and energy 2 % for 5 % In ≤ I ≤ Imax 0.5 % for 5 % In ≤ I ≤ Imax
RAM Capture of waveforms
Apparent power and energy 1 % for 5 % In ≤ I ≤ Imax 0.5 % for 5 % In ≤ I ≤ Imax
± 0.05 counts when Operating temperature - 10 °C to + 55 °C (K55 according to IEC61557-12)
0.5 inductive < PF < 0.5
± 0.02 counts when 0.5 inductive < PF < 0.5 capacitive
Power factor (PF) and cosM ± 0.1 counts when Operating humidity 95 % to 40 °C
± 0.05 counts when 0.2 inductive < PF < 0.2 capacitive
0.2 inductive < PF < 0.2
capacitive Storage temperature - 25 °C to + 70 °C
10 11
To order
Standard ENERIUM
Accuracy On-off On-off Analogue
Model Frequency Power supply Communication Reference
class inputs outputs outputs
ENERIUM 30 50 / 60 HZ 1 230 to 400 Vac/Vdc - 0 0 0 P01330821
ENERIUM 30 50 / 60 HZ 1 230 to 400 Vac/Vdc - 0 1 0 P01330822
ENERIUM 30 50 / 60 HZ 1 230 to 400 Vac/Vdc RS485 0 0 0 P01330823
ENERIUM 30 50 / 60 HZ 1 230 to 400 Vac/Vdc RS485 0 1 0 P01330824
ENERIUM 50 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc RS485 0 0 0 P01330805
ENERIUM 50 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc Ethernet 0 0 0 P01330806
ENERIUM 50 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc RS485 1 1 0 P01330807
ENERIUM 50 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc Ethernet 1 1 0 P01330808
ENERIUM 150 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc RS485 0 0 0 P01330809
ENERIUM 150 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc Ethernet 0 0 0 P01330810
ENERIUM 150 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc RS485 0 2 0 P01330811
ENERIUM 150 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc Ethernet 0 2 0 P01330812
ENERIUM 100 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc RS485 0 0 0 P01330831
ENERIUM 100 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc RS485 2 2 0 P01330832
ENERIUM 200 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc RS485 4 2 0 P01330833
ENERIUM 200 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc Ethernet 2 2 2 P01330834
ENERIUM 210 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc Ethernet 8 0 0 P01330835
906 211 132 – Ed. 7 – 12/2011 - Non-contractual document – Please confirm specifications when ordering.
ENERIUM 1 2 3 4 5 6 7 8 9
1 Model
50 ENERIUM 50 – Electrical energy – Load curves - Format 96 x 96
150 ENERIUM 50 + Trend curves - Format 96 x 96
6 On-Off outputs
100 ENERIUM 100 – Multi-energy - Trend curves - Format 144x144 0 none
110 ENERIUM 100 screenless version - Format 144x144 1 input (only on ENERIUM 50/150)
200 ENERIUM 100 + Load curves - Format 144x144 2 2 inputs
210 ENERIUM 200 screenless version - Format 144x144 4 4 inputs (except on ENERIUM 50/150)
300 ENERIUM 200 + Qualimetry 6 6 inputs (except on ENERIUM 50/150)
310 ENERIUM 300 screenless version 8 8 inputs (except on ENERIUM 50/150)
2 Frequency of network measured 7 Analogue inputs (ENERIUM 100/200 only)
0 50 / 60 Hz 0 none
1 400 Hz ( except on Enerium 100 / 200 class 0.5s / 300 ) 2 2 analogue inputs
4 4 analogue inputs
3 Auxiliary power supply 6 6 analogue inputs
0 80 to 265 Vac / 110 to 375 Vdc 8 8 analogue inputs
1 19.2 to 58 Vdc 8 Analogue outputs
4 Communication 0 none
0 RS485 2 2 outputs
1 Ethernet 4 4 outputs (except on ENERIUM 50/150)
Note : with choices 5, 6, 7 and 8, it is possible to have a maximum of 8 inputs and/or 9 Accuracy class
outputs (ENERIUM 100-110/200-210). 5 0.5 s (except on ENERIUM 300)
Note: for the Enerium 50/150, choices 5 and 6 only allow the following combinations : 2 0.2s (ENERIUM 200/210/300/310 only)
0-0, 1-1, 2-0, 0-2.
5 Metering (or On-Off) inputs Example : Enerium 200, frequency 50/60 Hz, 80 to 264 Vac auxiliary power supply, RS485
communication, 2 on-off inputs, no on-off outputs, no analogue inputs, no analogue
0 none outputs, Class 0.2s
1 1 input (only on ENERIUM 50/150) ¬ORDER¬%.%2)5-¬¬¬s¬ ¬s¬ ¬s¬ ¬s¬ ¬s¬ ¬s¬ ¬s¬ ¬s¬ ¬s¬
2 2 inputs
4 4 inputs (except on ENERIUM 50/150)
6 6 inputs (except on ENERIUM 50/150)
8 8 inputs (except on ENERIUM 50/150)
Accessories
Logiciels Optical head for ENERIUM 50/150 P01330403
Optical head for ENERIUM 100/110 - 200/210 – 300/310 P01330401
E.set P01330501
DIN-rail mounting kit for ENERIUM 30/50/150 P01330830
E.View P01330601
DIN-rail mounting kit for ENERIUM 100/200/300 P01330360
E.View+ P01330610
690 V / 400 V resistive voltage adapter
P01330402
(for wind-turbine applications)
Power supply for On-Off inputs
ACCJ1004
85 to 256 Vac/12 Vdc – 3.5 A (42 W)