RO180 Manual_rev100827

The document is a user manual for the Protegra CSTM RO EDI 180 Reverse Osmosis System, detailing its safe operation, installation, and maintenance. It includes sections on safety protocols, system features, and technical specifications, emphasizing the importance of adhering to the guidelines to prevent hazards. The system is designed for producing deionized water and operates with a purification process that includes reverse osmosis and electro-deionization.

Uploaded by

SOBHY KHELA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views

RO180 Manual_rev100827

The document is a user manual for the Protegra CSTM RO EDI 180 Reverse Osmosis System, detailing its safe operation, installation, and maintenance. It includes sections on safety protocols, system features, and technical specifications, emphasizing the importance of adhering to the guidelines to prevent hazards. The system is designed for producing deionized water and operates with a purification process that includes reverse osmosis and electro-deionization.

Uploaded by

SOBHY KHELA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 51

Manual

Protegra CSTM RO EDI 180


Reverse Osmosis System
with 2-Pass El-Ion® Electro Deionization

Catalogue no.: 3055


Siemens AG
Industry Sector
Industry Solutions Division
I IS WT HPS GER
Fahrenberg 8
22885 Barsbüttel, Germany
Tel.: +49 40 670868-6
Fax: +49 40 670868-44

rev100827
Subject to alternations without prior notice.
TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

Table of contents

1 General ....................................................................................................................................1
1.1 About this user manual 1
1.2 Symbols used in this manual 1
1.3 Liability and warranty 2
1.4 Copyright 2
1.5 Spare parts 2
1.6 Disposal 3
2 Safety.......................................................................................................................................3
2.1 Intended use 3
2.2 Contents of this manual 3
2.3 Changes and modifications to the equipment 4
2.4 User responsibility 4
2.5 Personnel requirements 4
2.6 Health and safety at work 5
2.7 Personal protective equipment (PPE) 5
2.8 Potential hazards 5
3 System features......................................................................................................................6
3.1 Purification process 7
3.2 Purification diagram 8
3.3 Security advice 8
4 Installation and start up.........................................................................................................9
4.1 Hose connections 9
4.2 Level control connection and power supply 10
4.3 Start up 10
5 System control .....................................................................................................................11
5.1 Display and function keys 11
5.2 First start 11
5.3 Settings 12
5.4 Energy saving mode 15
5.5 Maintenance 17
5.6 Service 18
6 Warning messages...............................................................................................................18
7 Maintenance and servicing .................................................................................................20
7.1 Adjustment of the operation pressure 20
7.2 Filter replacement 21
®
7.3 El-Ion electricity adjustment 22
7.4 El-Ion® nuts tightening 23
8 Technical data ......................................................................................................................24
8.1 Feed water requirements 24
8.2 System data 25
9 Appendix ..................................................................................................................................I
9.1 P&ID I
9.2 E.-drawing II
9.3 Consumables and spare parts III

Table of contents
TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

1 General
1.1 About this user manual
This user manual describes how to use the equipment safely and correctly. When operating this equipment,
it is essential that the user adhere to the safety instructions and operating instructions, the local accident
prevention regulations and general safety regulations.

Before using the equipment, the user must read the user manual, particularly the section on safety and the
relevant safety warnings. The user must fully understand the instructions before proceeding.

The user manual is a part of the equipment. It must be kept close to the equipment and be accessible at any
time for all users. Should the equipment be passed on to a third party, the manual must also be passed on to
the third party.

1.2 Symbols used in this manual


Issues relevant to safety are characterized in this manual according to the following symbols. These
warnings must be observed in order to operate the equipment safely and avoid accidents, damage or injury.

Warning! Risk of serious or fatal injury!

This symbol alerts the user to potential sources of hazards to health, injuries or fatal injuries. Do not operate
the equipment until you have completely understood the instructions and proceed accordingly.

Warning! Risk of electric shock!

This symbol alerts the user to the presence of uninsulated voltage that has the potential to cause serious or
even fatal injuries. Do not operate the equipment until you have completely understood the instructions and
proceed accordingly. All maintenance work must be performed by qualified service personnel.

Important!

This symbol alerts the user to potential sources of malfunctions or damage to the equipment if operated
improperly.

Note!

This symbol alerts the user to advice on efficient und trouble-free operation.

General Page 1 of 25
TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

1.3 Liability and warranty


With the benefit of many years of experience and expertise, this user manual and all the facts and
instructions in it have been written taking current legislation, state-of-the-art technology into account.

The user manual must be kept close to the equipment and available at all times for anyone intending to use
the equipment.

The user manual must be read before any work is carried out using the equipment! The manufacturer does
not accept liability for damage or faults that arise due to disregard for the instructions in the manual.

The text and diagrams depicted in this manual do not necessarily match the equipment you have received.
The diagrams and images are not on a scale of 1:1.

The equipment delivered to you may be slightly different to the equipment described and depicted here due
to specialized features, additional options or due to changes in technology. If you have any queries, please
contact the manufacturer.

We reserve the right to make technical changes to product and further develop it in order to improve its
functionality.

1.4 Copyright
This manual must be treated as a confidential document. It is only intended for use by those operating the
equipment.

All contents of this manual – text, diagrams, images etc. – are protected by copyright law and industrial
property rights. Anyone found violating these rights will be prosecuted.

The manual may not be passed on to third parties, copied – either in part or whole – or used for any other
purpose without the express and written consent of the manufacturers. Anyone found violating these
copyright laws must pay compensation. The manufacturer may also prosecute.

We reserve the right to exercise all industrial protection rights.

1.5 Spare parts


Only use original spare parts supplied by the manufacturer.

Important!

The wrong or faulty spare parts can lead to damage, malfunction or a complete breakdown of
the equipment.

All guarantee, service, damages and third party liability claims against the manufacturer, the manufacturer’s
representatives and dealers become null and void once unauthorized spare parts are used in the equipment.

General Page 2 of 25
TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

1.6 Disposal
If no return or disposal contract has been agreed on, please dispose of the disassembled components as
follows:

- Recycle scrap metal parts,


- recycle plastic parts,
- dispose of other components according to the material.

Important!

Electrical and electronic scrap and components, lubricants and other process materials must
be treated as hazardous waste and can only be disposed of by authorized waste disposal
facilities.

2 Safety
At the time this equipment was developed and produced, it complied with the current state-of-the-art
technology and is accepted as reliable and safe.

The equipment can represent a hazard if it is not operated by untrained personnel, if operated improperly or
not according to the manual.

The section on safety provides an overview of all the important issues relevant to personal safety and safe
and trouble-free operation.

The other sections of the manual also contain specific safety warnings and warning symbols that highlight
the possible hazards. Please also comply with the pictograms, signs, markings and inscriptions on the
equipment. These may not be removed and must always be visible.

2.1 Intended use


The equipment is only safe if operated as intended by this manual.

Important!

Any form of use or operation other than the intended use is improper and prohibited.

Claims of any kind made against the manufacturer or the manufacturer’s representatives are null and void if
the equipment is not operated as intended.

The operating company is liable for all damages caused by improper use. The intended use is described in
the manual and includes compliance with the operating conditions. The equipment may only be operated
together with the parts supplied.

2.2 Contents of this manual


Anyone intending to work with or use the equipment must read and understand the user manual before
operating the equipment. This also applies if the user has already operated similar equipment or devices of a
similar nature or has been trained by the manufacturer.

Reading and understanding the manual is the only way to protect against hazards, prevent mistakes and
operate the equipment safely and trouble-free.

We recommend that the operating company obtain written confirmation from each user that he/she has read
and understood the manual.

Safety Page 3 of 25
TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

2.3 Changes and modifications to the equipment


In order to avoid hazards and ensure that the equipment operates at its best, do not make any changes or
modifications to the equipment that have not been expressly authorized by the manufacturer.

Ensure that all pictograms, signs, markings and inscriptions on the equipment are always visible and never
removed. Damaged, missing or illegible pictograms, signs, markings and inscriptions must be replaced
immediately.

2.4 User responsibility


The user manual must be kept close to the equipment and available at all times for anyone intending to use
the equipment.

The equipment may only be operated in a technically flawless and safe state. The equipment must be
checked for damage before each start-up.

The instructions in the manual must be followed completely and without restriction!

When operating this equipment, it is essential that the user adhere to the safety instructions and operating
instructions, the local accident prevention regulations, general safety regulations and the relevant
environmental protection legislation.

The operating company and the authorized personnel within that company are responsible for operating the
equipment trouble-free and must define who is responsible for installing, operating, servicing and cleaning
the equipment.

2.5 Personnel requirements


Only authorized and trained personnel are allowed to operate the equipment. The user must have been
instructed about the potential hazards involved in using the equipment.

Authorized personnel are persons who sufficient training, knowledge, experience and understanding of the
relevant regulations to be able to assess the task given to him/her and identify potential hazards.

If a potential user does not have sufficient knowledge at his/her disposal, this person must be trained to be
qualified.

It must be clear who is responsible for equipment installation, operation, maintenance and servicing. These
competencies must be clearly defined and conformed to in order to prevent any uncertainties that may
compromise safety.

Only reliable personnel may work with and operate the equipment. Do not allow anyone to operate the
equipment in a way that compromises the safety of others or the environment or damages the equipment.

No one under the influence of drugs, alcohol or medication that impairs the ability to respond/react is allowed
to operate the equipment.

Please consider all other directives related to age and qualification when selecting potential users.

The user must ensure that other, unauthorized personnel keep a safe distance from the equipment.

Personnel must report to the operating company immediately if any changes become apparent which may
impair the safe operation of the equipment.

Safety Page 4 of 25
TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

2.6 Health and safety at work


Follow the safety and operating instructions given in this manual in order to avoid causing harm or damage
to persons and property while working with and on the equipment.

If these instructions are not observed, the equipment may become damaged or destroyed or may harm
persons.

The manufacturer is not liable for third party damages or compensation if the safety and operating
instructions in this manual or the local accident prevention regulations and general safety regulations are not
observed.

2.7 Personal protective equipment (PPE)

When working with this equipment, please wear goggles or another form of protective eyewear.

2.8 Potential hazards


This equipment has been subjected to a risk analysis. The subsequent equipment design and execution
corresponds to state-of-the-art technology.

The equipment is safe for use, provided it is operated as intended. A minimal residual risk cannot be
eliminated completely.

The equipment is run at high electrical voltage.

Warning! Risk of electric shock!

Electrical energy in the equipment can lead to serious injuries. The equipment presents a
danger to life if the insulation or individual components become damaged.

- Switch off the main power switch before carrying out maintenance, cleaning or repair work and
ensure that it cannot be switched on again while carrying out this work.
- Eliminate all voltage from the equipment when working on the electrical equipment.
- Do not remove or deactivate any safety equipment.

The manufacturer does not take any responsibility for injuries to third parties
caused by improper use of the system.

Safety Page 5 of 25
TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

3 System features
This water purification system is designed for the production of deionized Pure Water out of softened
drinking water from public supplies. Pure Water will be produced by a Reverse-Osmosis unit and the final
® ®
deionization by the El-Ion cell. The El-Ion electro-deionization removes last dissolved ions, particles and
®
bacteria from the water. The resin inside the El-Ion cell will be regenerated permanently by an electro-
chemical process and does not need to be exchanged. The system has to be connected to a level controlled
tank to regulate the production.

Production rate of deionized Pure Water is 180 liter per hour.


Typical characteristics are:

Conductivity under 0.1 µS/cm (resistivity over 10 MΩ-cm),


TOC concentration (Total Organic Carbon) under 30 ppb;
bacteria less than 5 cfu/ml
and particle rejection rate over 99%.
®
Currently recorded data and warning messages are shown on the system monitor. The El-Ion electricity
data are shown at indicators.

The production automatically runs in 3 different modes:

Operation mode: Pure Water production and tank filling


Shut down mode: Reverse-Osmosis and Electro deionization stop and are rinsed
Standby mode: System is ready for new production

All components of the system are assembled in a plastic coated steel frame standing on wheels.
The side coverings can easily be opened for maintenance works. The system corresponds to the latest
technology and to recent safety regulations. It can be installed and put into operation without the help of
customer service engineers.

System monitor with operation keys

Pressure gauge
®
El-Ion electricity indicators

Main switch ON / OFF

Fine Filter

Reverse-Osmosis module

®
El-Ion cell

System features Page 6 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

3.1 Purification process


The process flow with the main components is illustrated on the P&ID, see the appendix.
When the system is started in production mode, the inlet valve (V3.1) opens and the Reverse-Osmosis pump
(P3.1) starts. If the system is turned OFF, in case of feed water shortage, or if the tank is filled, this valve
closes and the reverse-osmosis pump stops.
The fine filter (F3.1) is a combination of activated carbon and filtration. It adsorbs organic chemicals like free
chlorine, insecticides, pesticides, and herbicides out of the water and removes particles larger than 5
microns.
The pretreated Feed water conductivity is monitored with a sensor (QIA+ Q1) and indicated with Q1.
If the conductivity exceeds the set point, a warning message will be displayed on the system monitor.
The supply of feed water is monitored with a pressure switch (PSA- P3.1). If the pressure falls below the
limit, a warning message will be displayed and the production stops, until the pressure is in the limit again.
The reverse-osmosis pump (P3.1) increases the inlet pressure for the Reverse-Osmosis process.
The operational pressure is indicated with a pressure gauge (PI3.1) and can be regulated with the pressure
control valve (V3.5).
The reverse-osmosis module unit (F3.2) removes about 98% of the salt content out of the water.
Moreover nearly all bacteria and viruses, heavy metal complexes, and organic molecules with a molecular
weight higher than 300 Daltons are rejected. The water including the ingredients is called concentrate, the
cleaned water is called permeate.
The concentrate partly flows to the waste water disposal via restriction (V3.6) and partly back to the reverse-
osmosis pump via flow control vlave (V3.5).
The service valve (V3.7) must be closed for normal operation (position crosswise to flow direction) and shall
be opened only by service technicians in case of maintenance works.
The conductivity of the permeate is monitored with a sensor (QISA+ Q2) and indicated with Q2.
If the conductivity exceeds the set point, a warning message will be displayed and the output of permeate
stops (V3.2 closes, V3.3 opens).
The permeate flows back to the RO-pump via check valve (V3.4). If the conductivity is in the limit, the
®
permeate flows to the El-Ion cell.
Three flow transmitters (FTA- 3.1 / FTA- 3.2 / FTA-4.1) monitors the permeate flow rate, concentrate flow
rate and sole flow rate in the system.
®
The El-Ion cell (E4.1) removes still remaining ions and particles out of the permeate by the principle of
electro-deionization. Positive and negative ions pass a membrane into a concentrate chamber and are
rinsed out by a permanent flushing stream. (see chapter 3.2 Purification diagram)
The concentrated water with accumulated ions is called brine.
The conductivity of this deionized permeate is monitored with a sensor (QIA+ Q3) and indicated with Q3.
If the conductivity exceeds the set point, a warning message will be displayed on the system monitor.
The temperature of the water is measured by a temperature sensor (TA+ 4.1) and displayed on the system
monitor.
The system has to be connected to a tank (T5.1) with level control (LS-5.1) to regulate the production. When
®
the tank is filled (100%), the production stops and the system turns into the shut-down mode. El-Ion cell and
RO membranes are rinsed. In the stand-by mode the system is ready for new production. If the level falls
below 80%, the production starts again.
The system can be operated in a service mode for maintenance works.
OPTION:
An external distribution pump can be connected with the system. If the tank level drops below 8%, the pump
would be stopped for dry running protection.
An external UV-Lamp can be connected with the system to protect the product water against bacterial
contamination.
For economical use the optional distribution pump or UV-Lamp can be operated in interval mode with 2
separate intervals and day/night program.

System features Page 7 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

3.2 Purification diagram

®
Schematic diagram of the El-Ion cell. The conductivity will be decreased by an electro-chemical process
®
within the El-Ion cell. The ion exchange chamber provide for a salt removal from the water. Concentrate will
be drained. The conductivity value of the ultra pure water will be lower than 0.5 µS/cm.

3.3 Security advice


®
During the electro deionization process a small amount of hydrogen gas will be produced inside the El-Ion
cell. This gas will be carried out of the cell through the product water stream.
During storage of the product water hydrogen can accumulate in the tank in case of insufficient air
ventilation.

Important!

The tank opening must be clearly marked with the enclosed fire warning labels.
No fire or fire causing devices are allowed near the unit and the tank.
Fire warning labels are enclosed this manual.

System features Page 8 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass
pass El-Ion Electro-Deionization
Catalogue No. 3055

4 Installation and start


tart up
Important!

Before installing the system please check if the feed water meets the specification
demands. They are listed in chapter 8.1 - Feed water requirements
equirements.

4.1 Hose connections

Feed Water Inlet Product water outlet

Concentrate Outlet
Brine outlet

– Screw all tubes on their appropriate connectors (R=¾”)

– Lead the CONCENTRATE and BRINE tubes to the waste water disposal (D=8mm)

Important!

Concentrate, brine tubes


tube have to be directed with a linear slope
pe to the waste water
disposal.
Any reduction of the diameter, loops, siphons or bucklings have to be provided, other
otherwise
the system will be damaged. A minimum um safety distance of 2 cm between draining tube
and waste water disposal
d inlet must be realized.

Installation and start up Page 9 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

4.2 Level control connection and power supply


The System must be connected with a level controlled tank.
The level control wires have to be tightened on the terminal bock of the control cabinet.

Important!

The system control is factory preset for float switch measurement.

The connector for the level control is located on the rear inner panel of the system.

Terminal block

Level sensor
connection

Control cabinet Rear side

OPTION:
– Open the control cabinet door

– Stick the distribution cable / UV-Lamp cable through a free cable entrance rear side of the control
cabinet

– Tighten the wires on the terminal block in accordance to the circuit diagram

– Tighten the cable gland

– Connect the power supply cable with the mains

4.3 Start up
– Open feed water supply and check for impermeabilities of all connections

– Start the system with the ON function key

– Choose the First Start item within the Start Selection Screen
for the first water filling of the system after installation

– System is ready for operation

Note!

Before Normal Operation it is highly recommended to study the chapter “System Control”
keenly.

Installation and start up Page 10 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

5 System control
5.1 Display and function keys

Display of device type, Serial Number and control version

Function keys
ON : System Start and Start Selection Screen
: Menu selection and number input
ENTER: Confirmation
: Menu selection and number input
Menu : Superior menu item
OFF : Switch off key (Attention: the system is still power connected)

5.2 First start


First Start
When starting the system for the first time or after the system has not been
used for a while choose “first start” to start an initial rinse cycle. The inlet
valve opens and water is flushed to drain.

Flush
The modules will be rinsed for 120 seconds.
After the flushing program the system will switch into normal opration
mode.

Normal Operation Display


Q1: Feed water quality
Q3: Product water quality
Q2: permeate quality
temp: Temperature
SSR: Salt rejection rate

Parameter of each displayed line can individually be chosen in the main


menu settings
FT3.1: Flow rate product water
FT 3.2: Flow rate concentrate
FT 4.1: Flow rate brine El-Ion cell
temp: Temperature
SSR: Salt rejection rate

System control Page 11 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

5.3 Settings
ON ► Start selection screen ► Main Menu
Confirmation starts the main menu or simply press the menu key during
normal operation.

Main Menu
– Settings: System configuration
– Maintenance: Operation counter and Service Operation
– Service: Technical service configuration

Main Menu ► Settings


Parameter settings for system, display, and interval-mode

Note:
The timer P5.1 will only be displayed, if external pump 5.1 is switched on

Main Menu ► Settings ► Language


– German
– English

Main Menu ► Settings ► Date


Input of the date: month / day / year (MM/DD/YY)

Main Menu ► Settings ► Time


Input of the time: hours : minutes (hh:mm)

Main Menu ► Settings ► µS/cm MΩcm Display


Selection of water quality unit (conductivity / resistivity)
– conductivity [µS/cm]
– resistivity [MΩcm]

System control Page 12 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

Main Menu ► Settings ► Temperature compensation


Sets temperature compensation for conductivity/resistivity readings at the
standard temperature of 25°C or turns compensation off.
– automatic compensation
– compensation off
Deviations in water quality measurements due to change in temperature
can be compensated to a temperature of 25°C. Choose “automatic
compensation” or “compensation off” with the arrow keys and confirm with
the enter-key.

Main Menu ► Settings ► Quality Q1 / Q2 / Q3


Conductivity limit of quality control Q1, Q2, and Q3

Main Menu ► Settings ► Quality Q1 / Q2 / Q3 ► Critical Value


Input of the conductivity limit.
If this limit is exceeded, a warning message will be displayed.

Main Menu ► Settings ► Temperatur


Water temperatur limit

Main Menu ► Settings ► Temperatur ► Critical Value


Input of the temperature limit.
If this limit is exceeded, a warning message will be displayed.

Main Menu ► Settings ► Temperatur ► Arlarm delay


Input of the alarm delay in seconds.

Main Menu ► Settings ► FT3.1 / FT3.2 / FT4.2 settings ►


- Selection of flow rate unit in liter / gallon.
- Enter a limit for the flow sensor. If this limit is exceeded, an alarm
will be displayed..
- A delay time in seconds for that alarm as well as a range border
minimum and maximum can be determined.
Change the digits and confirm with the enter-key

Main Menu ► Settings ► Main display


Parameter selection for each row displayed in normal operation

System control Page 13 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

Main Menu ► Settings ► Main display► row 1 / 2 / 3


Selection of the parameters for each row to be displayed in normal
operation.
Parameter selection for each row
– Q1: feed water quality
– Q2: RO permeate quality
– Q3: deionized water quality
– Temp.: deionized water temperature
– SRR: salt retention rate
– FT3.1: RO permeate flow rate
– FT3.2: RO concentrate flow rate
– FT4.1: deionized water flow rate
– Inactive

Main Menu ► Settings ► energy-saving-mode (Interval-mode)


The pump / UV-Oxidizer (option) can be operated with:
– 2 separate interval periods
– Each period with permanent day operation and without night operation
– Each period with individual day and night settings
– Day and night operation with pauses, while the pump / UV is stopped
[ See chapter 5.4 Main Menu ► Settings ► energy-saving-mode ]

Main Menu ► Settings ► distr. Pump P5.1


The pump can be operated with:
– ON
– OFF
Note:
The timer P5.1 will only be displayed, if external pump 5.1 is switched on

Main Menu ► Settings ► Data Port


Selection of the data output signal
– Signal for PC connection
– Signal for printer connection

Main Menu ► Settings ► Data Port ► PC/Printer ► interval data port


Period of the data output for the printer.
Input of the period in minutes.

System control Page 14 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

5.4 Energy saving mode


Main Menu ► Settings ► energy-saving-mode ► Distr. Pump P5.1
Example:
Working week day operation, night pauses and Weekend pauses.

Main Menu ► Settings ► Timer Booster pump ► Week day 1


Display of the days from Sunday to Saturday.
Selection of the days with number “1”
st
Example: 1 Interval, Working Week
Input Monday until Friday

Main Menu ► Settings ► Timer Booster pump ► Start Time 1


Selection of the start moment for day-time operation
st
Example: 1 Interval, Working Week
Input 08:00 o’clock

Main Menu ► Settings ► Timer Booster pump ► Finish Time 1


Selection of the end for day-time operation
st
Example: 1 Interval, Working Week
Input 17:00 o’clock

Main Menu ► Settings ► Timer Booster pump ► Interval 1


– Selection of interval or permanent mode
– Operation during days and night
– Pauses during days and nights

Main Menu ► Settings ► Timer Booster pump ► Interval 1 ► Mode


Selection of the mode:
– Permanent is operation during the day-time only
– Interval is operation with different day and night settings
st
Example: 1 Interval, Working Week
Input permanent operation

For Intervall operation see Intervall 2

Main Menu ► Settings ► Timer Booster pump ► Week Day 2


Display of the days from Sunday to Saturday.
Selection of the days with number “1”
nd
Example: 2 Interval, Weekend
Input Sunday and Saturday

Main Menu ► Settings ► Timer Booster pump ► Start Time 2


Selection of start moment for day-time operation
nd
Example: 2 Interval, Weekend
Input 00:00 o’clock

System control Page 15 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

Main Menu ► Settings ► Timer Booster pump ► Finish Time 2


Selection of the end for day-time operation
nd
Example: 2 Interval, Weekend
Selection of 23:59 o’clock

Main Menu ► Settings ► Timer Booster pump ► Interval 2 ► Mode


Selection of the interval mode:
– Permanent is operation during the day-time only
– Interval is operation with different day and night settings
nd
Example: 2 Interval, Weekend
Input interval operation with Zero interval settings

Main Menu ► Settings ► Timer Booster pump ► Interval 2


– Selection of interval or permanent mode
– Operation during days and night
– Pauses during days and nights

Main Menu ► Settings ► Timer UV-Lamp ► Interval 1 / 2


► Day operation
Input of the operation time during days,
only valid in case of interval mode operation.
Example: complete week interval
Input 120 minutes

Main Menu ► Settings ► Timer UV-Lamp ► Interval 1 / 2


► Day pause
Input of pauses during days,
only valid in case of interval mode operation.
Example: complete week interval
Input 60 minutes

Main Menu ► Settings ► Timer UV-Lamp ► Interval 1 / 2


► night operation
Input of the operation time during nights,
only valid in case of interval mode operation.
Example: complete week interval
Input 120 minutes

Main Menu ► Settings ► Timer UV-Lamp ► Interval 1 / 2


► Day pause
Input of pauses during nights,
only valid in case of interval mode operation.
Example: complete week interval: Input 60 minutes

System control Page 16 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

5.5 Maintenance
For some changes in the maintenance menu a password is required.
The user password consists of the first four ciphers of the serial number.

Main Menu ► Maintenance


Confirmation starts the maintenance menu.
The user password consists of the first four ciphers of the serial number.

Main Menu ► Maintenance ► Selection


Service operation switches the system from standby mode despite of a full
tank level into operation e.g for testing procedures. This feature requires a
Service password. It is allotted to service technicians only.

Op hours: Operation counters


- Service
- RO-pump P3.1
- Pump P5.1
®
- El-Ion cell E4.1
- System
- I/O status report

Main Menu ► Maintenance ► Distribution Pump P5.1


Display of the current operating hours. After having maintained the system
the attended time must be reset.
“Op.hrs. service” displays the current operating hours of the system.
Once the components exceeded the maximum operation hours a message
will be displayed.

Main Menu ► Maintenance ► Selection► reset


®
After having maintained a pump, the El-Ion cell or the system in the
corresponding menu the attended time must be reset.

Main Menu ► Maintenance ► I/O status report


Displays the in- and outputs of the I/O boards.

Main Menu ► Maintenance ► I/O status report ► Selection


Displays the in- and output signals of the I/O boards.

System control Page 17 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

5.6 Service
For some changes in the maintenance menu a password is required.

Main Menu ► Service


Confirmation starts the service menu.

Main Menu ► Service ► Selection

Note: Only change any settings after consultation with the customer
service!
In the service menu both I/O-boards, the flow transmitter and the tank can
be calibrated, settings concerning the tank can be adjusted.
The extended menu is requires a service password. It is allotted to service
technicians only.

6 Warning messages
Warning Meaning Measure
1: Q1 The measured feed water conductivity Check the feed water pretreatment.
above setpoint QIA+Q1 exceeded a set limit. Check the feed water conductivity.
2: Q2 The measured permeate conductivity If the measured conductivity of the RO
above setpoint QIA+Q2 exceeded a set limit. permeate is too high, the RO modules
must be replaced.
3: Q3 The measured electro-deionized If the measured conductivity of the
above setpoint permeate conductivity QIA+Q3 electro deionized permeate is too high,
®
exceeded a set limit. the functionality of the El-Ion cell must
be tested.
Inform the customer service.
5: concentrate RO The measured flow rate F3.2 of the Check the feed water supply.
below alarm value concentrate exceeded a set limit. Check hoses for any constrictions.
Check the functionality of the RO
pump P3.1
6: temperature The measured product water Check the settings of the temperature
above setpoint temperature TA+4.1 exceeded a set limit.
limit. Check the temperature of the ambient
temperature and of the product water.
8: feed pressure The feed water pressure measured by Raise the feed water pressure.
below alarm value PSA-3.1 is below the set limit. Change the filter cartridge F3.1.
9: system stop System is stopped due to an operating Reset the error by pressing the on key.
start with on key fault. This warning appears together
with other warning messages.
10: tank is empty The product water tank is empty. The Check the feed water supply.
level below setpoint circulation pump is stopped to protect it Check the functionality of the RO
against running dry. process.
11: cable fault A fault in the tank measurement cable Check the cable of the tank level
tank measurement has been detected. The tank level measurement and its connection to the
cannot be displayed correctly. system.

Warning messages Page 18 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

12:attention The service operation mode has been Initiate necessary actions in case of a
service operation started, which means that the system tank overflow.
produces product water permanently.
Tank levels will be ignored.
13: Maintenance The system is maintained by the
by customer service customer service.
14: ext. fault 1 An external device signals a fault. Analyze the external fault signal.
start with on key
15: failure controller A problem of the power supply of the Inform the customer service.
®
El-Ion cells El-Ion cell has been detected.
16: replace The maximum operating hours of the Replace the UV lamp 5.1 of the tank.
ext. UV lamp 5.1 external UV lamp 5.1 are exceeded. Reset the expired operating hours of
the UV lamp.
®
17: concentrate flow The flow rate of the El-Ion cell Check the flow rate of the concentrate.
below setpoint concentrate is below the set limit. Check the limit settings for FTA-4.1.
Check hoses for any constrictions.
If the problem maintains, inform the
customer service.
18: product flow The flow rate of the product water is Check the flow rate of the product
below setpoint below the set limit. water.
Check the limit settings for FTA-3.1.
Check the function of the RO process.
Check the RO concentrate flow rate
FTA-3.2.
Check the functionality of the RO
pump P3.1.
Check the feed water supply.
Check hoses for any constrictions.
If the problem maintains, inform the
customer service.
20: con measurement All four conductivity measurements are Check if air is located the
out of range displayed in an accumulative alarm. measurement chamber and/or if there
On the display an arrow indicates the is a cable break.
direction in which the conductivity Deaerate the system.
exceeded the range (LF1 – LF4).

Warning messages Page 19 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

7 Maintenance and servicing


7.1 Adjustment of the operation pressure
The operation pressure is shown on the pressure gauge (PI3.1) located at the front side.
The pressure has to be in a rang between 6 and 14 bar.
If the pressure is out of the range, it can be adjusted with a screw on top of the pressure control (V3.5)

Pressure control (V3.5)


Adjustment screw

Maintenance and servicing Page 20 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

7.2 Filter replacement

The replacement of the fine filter (F3.1) has to be chosen individually and depends on the contamination of
the feed water.

In case of feed water with potable water quality, a replacement of the filter is recommended all 3 months.

Filter attachment

Filter body

Replacement of the filter:

– Stop the system with the OFF function key

– Open left cabinet side

– Wait for the pressure reduction indicated on the pressure gauge (PI3.1)

– Unscrew the filter case anticlockwise with the supplied filter gripper

– Replace the filter cartridge

– Start the system with the ON function key

– Check for impermeability of all connections and close the left cabinet side again

– System is ready

Maintenance and servicing Page 21 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

7.3 El-Ion® electricity adjustment


If the system detects any problem, warning messages will be displayed on the system’s screen.
Follow the given instructions to correct the fault or get in contact with the customer support.
®
The El-Ion electricity meters on the front have to be checked temporarily:

The current is factory preset to 8 A Cell 1 and 4 A Cell 2. The voltage of the cells depends on the feed water
quality.

The adjustment potentiometer is located on the aluminum plate mounted on the ground of the electric
cabinet.

Control cabinet

®
EL-ION Potentiometer (blue)

®
El-Ion circuit board

Maintenance and servicing Page 22 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

7.4 El-Ion® nuts tightening

Important!

®
The nuts of the El-Ion cell must be tightened every 12 months with a torque wrench.

®
EL-ION cell
Nuts and counter nuts

Size of the nuts is M8. Torque of


the nuts is 16 Nm.

– Stop the system with the OFF function key and turn OFF the feed water supply

– Remove the power supply cable from the mains

– Open the side coverings

– Remove the nuts protective caps

– Hold the counter nuts with a wrench, tighten all nuts with a torque wrench one by one for 2 or 3
times

– Attach the protective caps again

– Plug in power supply cable, turn on water supply, start the system with the ON function key

– Check for impermeability of all connections

– Close the side coverings again

– System is ready for operation

Maintenance and servicing Page 23 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

8 Technical data
8.1 Feed water requirements
Before installation, please check if feed water fulfills following specification:

bar 2.0 – 6.0


Feed water pressure
psi 29 – 87.0
3
L /H 0.34
Feed water flow max.
GPM 1.5
Feed water conductivity µS/cm < 1400

Free chlorine mg/L < 0.1

CO2 mg/L < 20

Silt Density Index (SDI) <3

Langelier Index (LI) <0

Silica mg/L < 15

Iron mg/L < 0.1

Manganese mg/L < 0.05

pH 3–9
°C 5 – 35
Temperature
°F 45 – 90
All given flow rates are based on feed water temperature of 15°C (59°F).
The RO permeate flow will change approx. 3% for each °C (decrease for lower values, increase for higher
values).

Important!

Feed water must be softened!

Technical data Page 24 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

8.2 System data

Pure Water production LPH 180


3
m /h 0,34
Feed water flow
GPH 1,5
Conductivity µS/cm < 0.5

Resistivity MΩcm >2

Typical Conductivity µS/cm < 0.1

Typical Resistivity MΩcm > 10

Bacteria cfu/ml <5

TOC concentration ppb < 30

Particle rejection % > 99

Feed water inlet R 3/4″

Product water outlet R 3/4″

Concentrate outlet R 3/4″

Brine outlet R 3/4″


V 230
Power supply
Hz 50
Height/Width/Depth mm 1650 / 600 / 600

Weight kg 150

Technical data Page 25 of 25


TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

9 Appendix
9.1 P&ID

Appendix I
1 2 3 4 5 6 7 8

1pass Reverse Osmosis unit Elektrodeionisation (EDI)


A A

n.cr. (after the first failed start)


cr. (after the 10-th failed start)

max. backpressure 0,5[bar]; 7,25[psi]


restart delay 60s+15s
after successful start 10s alarm
suppression
7,25[psi]; 0,5[bar]

range: n.cr.(delay 120s)


4,3-29[psi]; 0,3-2,0[bar] 0,71[GPM]; 160[l/h]; 129[Hz]
max.:145[psi]; 10[bar]
range with low flow nuzzel:
art.06987 0,1-1[GPM]; 23-227[L/h]

PSA- 13[bar]
input: 4.5 to 24 VDC; 12mA
output: 13-186Hz;
3.1 0-232[psi]; 0-16[bar]
art.00279-1
art.07377-5 cr.(delay 300s)
PI

distribution system
0,2[µS/cm]; (0-0,3/3µS/cm)
FTA-
cr.(delay 300s)

storage tank and


Product water to
3.1
1400[µS/cm] C=0,1
3.1 art.02505

(0,55KW: 115V/60Hz; 8,5A)


art.07725 1/4"male

QIA+ QIA+

2.Pass Cell 2(4A; 5-24VDC)


1.Pass Cell 1(8A; 5-24VDC)
cr.(delay 300s)

Attention!
20[µS/cm]
Q3

female thread

female thread
Q1

output 1/4"
input 1/4"
B art.02501 B
TA+

24VDC; 0,15A)
art.03352-6
QISA+

24VDC; 0,15A)
4.1
D=6mm;
1/4"male
F3.2 Q2
3/4"male
RO Pass 1 3/4"BSP

3/4" male thread


hose

3/4"; d16; DN12


3/4"male

3/4"female 3/4"male
3/4" female DN12; L/- M 3/4"BSP
hose DN10; L/-
3/4"male
3/4"female 3/4"male - + - 3/4"male

DN10; L/-

feedwater from 1,48[GPM];


DN12; L/L
510 mm
360 mm DN12; L/L
315 mm 1 x 03205
220 mm 820 mm

prefiltration and 335[l/h] 3/4"

softener 0,88[GPM];
4,01[GPM]; 3/4"; d32 0,792[GPM];
art.04990-1 200[l/h] art.04990-1
910[l/h] DN25
P3.1 V3.2
180[l/h]

art.08550
V3.1 3/4"BSP
hose
3/4"BSP
hose
art.03350 V3.5 3/4"female
DN10; L/-
820 mm
0-100[PSI];
V4.1
3/4"BSP 24VDC; 0,15A) 3/4"BSP
male thread 3/4" 0-6,8[bar] 3/4" male thread

art.04990-1
femal male
3/4"

V3.3 1/4" flex tube


art.02742
F3.1 DN10; L/L
1635 mm 3/8"female
650 mm; black

JG;8mm
art.03242-2 DN10; L/- 3/4"male
1300 mm

output 1/8"male
E4.1

art.03175
{single filter housing}

input 1/8"male
C C
{art.01224-2 wrench}
V3.4 Two-Pass EDI
DN10; L/L art.16250
150 mm
2,42[GPM]; 3/8"female
200[l/h]
FTA-

0,079[GPM]; 18[l/h]
3/4"BSP
4.1

Recovery=90%
hose
1/4" flex tube art.06533
800 mm; black 0,9-60[l/h];
0,004-0,264[GPM]
art.03161-1 cr.(delay 120s)
0,062[GPM]; 14[l/h]
V3.7 n.cr.(delay 120s)
xx[GPM]; xxx[l/h] V3.6
If Recovery>93%

D=8mm; flex tube


If Recovery>xx%
xxx mm; black
input: 4.5 to 24 VDC; 12mA
output: 13-186Hz;

Recovery: 60%
0,6[GPM];
FTA-
input 1/4"

135 [l/h]
female thread

3.2 output 1/4"


female thread
art.07377-5
D D
range with low flow nuzzel:
0,1-1[GPM]; 23-227[L/h] 3/4"BSP
male thread

min.2,5cm; 1 inch
3/4"BSP
male thread

free entrance
Feed water specification
V3.1 solenoid valve {24VDC, NC; art. 04990-1} Feed water pressure 2,0-6,0 bar
V3.2 solenoid valve {24VDC, NC; art. 04990-1} 29-87 psi
V3.3 solenoid valve {24VDC, NC; art. 04990-1} 0,34 m³/h
V3.4 check valve {art. 03175} Feed water flow 1,5 GPM
V3.5 flow control valve {art. 02742}
V3.6 adjustable flow restriction Feed water conductivity < 1400 µS/cm
E V3.7 ball valve {only for service operation{art. 03161-1} Free Clorine < 0,1 mg/l
CO2 max. < 20 mg/l
Scope of supply
F3.1 active carbon filter {with 1µm screen}
{cartridge art. 08550} Silt Density Index (SDI) <3
{wrench art. 01224-2} Silica < 15 mg/l
F3.2 RO Pass 1 {1x modul TW 30 - 4040; art. 03205} Iron (FE) < 0,1 mg/l Designed for: DO NOT SCALE DRAWING REVISION 05
Manganese (Mn) < 0,05 mg/l
Siemens Water Technologies ID.No.: 3055
P3.1 RO-pump {brass; clamp type; RO pass1} pH-Range 3-9
standard-catalog-system
V4.1 adjustable flow restriction Langelier-Index <0 (negativ)
No. Changing Date NAME NAME DATE TITLE:
V4.2 tap valve 5 -35 °C
Temperature 01 from AutoCAD to Solidw. 09.12.2008 BC
45 - 90 °F DRAWN BC 09.12.2008
PSA- pressure switch {switch & alarm function; min. detection}
The Langelier-Index has to be negativ
02 Conversion to SolidWorks 26.02.2009 TK
CHK'D TK 20.08.2010 Protegra CS™ RO EDI 180
PI pressure gauge {indication}
QI conductivity meter {indication}
03 Layer added 16.11.2009 BC (flow sheet_P&ID)
Attention! all given flow rates are based on feed water
F QISA+ conductivity meter {switch & alarm function; max. detection} temperature of 59[F]; 15°[C]
04 new siemens logo 08.06.2010 BC Dry weight: 120 [kg]
TA+ temperature sensor {alarm function; max. detection} The RO-permeate flow will change approx. 3% for each
FTA- flow turbine {with alarm generation; min. detection} degree C (drop for lower values; increase for higher values
05 new product names 20.08.2010 BC Siemens AG
I IS WT IND HPS GER
DWG NO. A3
05 Flow-turbines
F3.2 geändert v.
20.08.2010 BC Fahrenberg 8
22885 Barsbüttel, Deutschland
3055_P&ID_Rev05 page
05 art.03205-11 in 03205 20.08.2010 BC
Tel.: +49 (40) 670868-6
1/1
1 2 3 4 Fax: +49 (40) 670868-44 Order-No.: Customer-PO-No.:
TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

9.2 E.-drawing

Appendix II
TM
Protegra CS RO EDI 180
Reverse-Osmosis system
®
with 2-pass El-Ion Electro-Deionization
Catalogue No. 3055

9.3 Consumables and spare parts

Label Part Article No

F3.1 Activated carbon filter 0,1 µm 08550

F3.2 RO module 03205

Label Part Article No

E1 System control 05697-00


®
E4.1 El-Ion cell E310 2-pass 16250

F3.1 Filter housing 10” 03242-2

FTA-3.1 Flow turbine 07377-5

FTA-3.2 Flow turbine 07377-5

FTA-4.1 Flow turbine 06533

P3.1 RO pump 1000 l 03350

P3.1 RO motor 03352-6

PI3.1 Pressure gauge 0…16 bar 00279-1

PSA-3.1 Pressure switch 06987

QIA+Q1 Conductivity sensor 07725

QISA+Q2 Conductivity sensor 02501

QISA+Q3 / TA+4.1 Conductivity sensor 02505

V3.1, V3.2, V3.3 Solenoid valve 04990-1

V3.4 Check valve 03175

V3.5 Pressure control valve 02742

V3.7 Service ball valve 03161-1

none Filter wrench 01224-2

none System wrench 02336

none Switching power supply; 100 … 230 V 08258-13

none Transformer; 2 x 115 V; 50/60 Hz 80736-1

none Volt meter; 40 V 08335-11

none Ampere meter; 10 A 08335-3