CALYPSO Installation
CALYPSO Installation
ENGLISH
AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE equipment should be complied with.
WITH THE EUROPEAN REGULATIONS IN FORCE: • Electromechanical actuators for gates are not intended to be
EN 60204-1, EN 12445, EN 12453, EN 13241-1, EN 12635 used by people (including children) with diminished physical,
sensory or mental capacity, or lacking in experience or
• The installer must provide for a device (es. magnetotermical knowledge, unless they are under supervision or have been
switch) ensuring the omnipolar sectioning of the equipment instructed in use of the actuator by a person responsible for
from the power supply. The standards require a separation of safety.
the contacts of at least 3 mm in each pole (EN 60335-1).
• The plastic case has an IP44 insulation; to connect flexible or V2 has the right to modify the product without previous
rigid pipes, use pipefittings having the same insulation level. notice; it also declines any responsibility to damage or
injury to people or things caused by improper use or wrong
• Installation requires mechanical and electrical skills, therefore it
installation.
shall be carried out by qualified personnel only, who can issue
the Compliance Certificate concerning the whole installation
(Machine Directive 2006/42/CEE, Annex IIA).
• Also the automation upstream electric system shall
comply with the laws and rules in force and be carried out
workmanlike.
• We recommend to make use of an emergency button, to be
installed by the automation (connected to the control unit DISPOSAL OF THE PRODUCT
STOP input) so that the gate may be immediately stopped in
case of danger. As for the installation operations, even at the end of this product’s
• For correct installation of the system, we recommend life span, the dismantling operations must be carried out by
following the instructions issued by UNAC very carefully. qualified experts.
• This instruction manual is only for qualified technicians, who
specialize in installations and automations. This product is made up of various types of materials: some can be
recycled while others need to be disposed of. Find out about the
• The contents of this instruction manual do not concern the recycling or disposal systems envisaged by your local regulations
end user. for this product category.
• Every programming and/or every maintenance service should
be done only by qualified technicians. Important! – Parts of the product could contain pollutants or
• Anything not expressly described in these instructions is hazardous substances which, if released into the environment,
prohibited; unforeseen uses may be a source of danger to could cause harmful effects to the environment itself as well as to
people and property. human health.
• Do not install the product in explosive environments and
atmospheres: the presence of inflammable gases or fumes is a As indicated by the symbol opposite, throwing away this product
serious safety hazard. as domestic waste is strictly forbidden. So dispose of it as
differentiated waste, in accordance with your local regulations,
• Do not make any modifications to any part of the automation or return the product to the retailer when you purchase a new
device, or the accessories connected to it, unless described in equivalent product.
this manual.
• Any other modifications will void the warranty on the product. Important! – the local applicable regulations may envisage heavy
• The installation steps should be conducted so as to avoid rainy sanctions in the event of illegal disposal of this product.
weather, which can expose electronic circuits to dangerous
water seepage.
• All operations requiring the casing of the device to opened
should be performed with the control unit disconnected from
the electricity supply and with a warning notice displayed, for
example: ”CAUTION, MAINTENANCE IN PROGRESS”.
• Avoid exposing the device close to sources of heat and flame. TECHNICAL SERVICE
• In the event of interventions on automatic or differential For any installation problem please contact our Customer Service
breakers or fuses, it is essential that faults be identified and at the number +39-0172.812411 operating Monday to Friday
resolved prior to resetting. In the case of faults that cannot from 8:30 to 12:30 and from 14:00 to 18:00.
be resolved using the information to be found in this manual,
consult the V2 customer assistance service.
• V2 declines all responsibility for failure to comply with good
construction practice standards in addition to structural
deformation of the gate that might occur during use.
• V2 reserves the right to make modifications to the product
without prior warning.
• Installation/maintenance personnel should wear individual
protection devices (IPDs), such as overalls, safety helmets,
boots and gloves.
-7-
PRELIMINARY CHECKS AND IDENTIFICATION OF THE TYPE TO BE USED
The automation device should not be used until installation, as specified in “Testing and start-up”, has been performed.
It should be remembered that the device does not compensate for defects caused by improper installation, or poor maintenance, thus, prior
to proceeding with installation, ensure that the structure is suitable and meets current standards and, if necessary, perform any structural
modifications aimed at the implementation of safety gaps and the protection or segregation of all crushing, shearing and transit zones, and
verify that:
ENGLISH
Warning: The minimum safety level depends on the type of use; please refer to the following outline:
GROUP 1 - Only a limited number of people are authorised for use, and closure is not in a public area. Examples of this type are gates inside
business premises, where the sole users are employees, or a part of them who have been suitably informed.
GROUP 2 - Only a limited number of people are authorised for use, but in this case, closure is in a public area. An example of this may be a
company gate that accesses onto a public street, and which is only used by employees.
GROUP 3 - Anyone can use the automated closure, which is thus located on public land. For example the access gate to a supermarket or
an office, or a hospital.
PROTECTION A - Closure is activated by means of a control button with the person present, i.e. with maintained action.
PROTECTION B - With the person present, closure is activated by a command controlled by means of a key-switch or the like, in order to
prevent use by unauthorised persons.
PROTECTION C - Restricts the force of the leaf of the door or gate. I.e., in the case of the gate striking an obstacle, the impact force must
fall within a curve established by the regulations.
PROTECTION D - Devices, such as photocells, capable of detecting the presence of people or obstacles. They may be active on just one side
or on both sides of the door or gate.
PROTECTION E - Sensitive devices, such as footboards or immaterial barriers, capable of detecting the presence of a person, and installed in
such a way that the latter cannot be struck in any way by a moving leaf or panel. These devices should be active within the entire “danger
zone” of the gate. The Machinery Directive defines “Danger Zone” as any zone surrounding and/or near machinery where the presence of
an exposed person constitutes a risk to the health and safety of that person.
The risk analysis should take into consideration all danger zones for the automation device, which should be appropriately
protected and marked.
In a clearly visible area, apply a sign with information identifying the motorised door or gate.
The installer should provide the user with all the information relating to automatic operation, emergency opening and
maintenance of the motorised door or gate.
-8-
EU DECLARATION OF CONFORMITY
AND DECLARATION OF
INCORPORATION OF PARTLY
COMPLETED MACHINE The relevant technical documentation is available at the national
Declaration in accordance with Directives: 2014/35/UE (LVD); authorities’ request after justifiable request to:
2014/30/UE (EMC); 2006/42/CE (MD) ANNEX II, PART B V2 S.p.A., Corso Principi di Piemonte 65, 12035, Racconigi (CN),
ENGLISH
Italia
The manufacturer V2 S.p.A., headquarters in Corso Principi di
Piemonte 65, 12035, Racconigi (CN), Italy The person empowered to draw up the declaration and to provide
the technical documentation:
Under its sole responsibility hereby declares that: Sergio Biancheri
the partly completed machinery model(s): Legal representative of V2 S.p.A.
CALYPSO400-230V, CALYPSO500-230V Racconigi, il 01/06/2019
CALYPSO600-230V
CALYPSO400-120V, CALYPSO500-120V
CALYPSO600-120V
TECHNICAL DATA
Capacitor µF 8 8 8 25 25 25
Working temperature °C -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50
Protection IP 44 44 44 44 44 44
Working cycle % 30 30 30 30 30 30
-9-
INSTALLATION LAYOUT
6 5
ENGLISH
A
4 2
1 D 1
- 10 -
INSTALLATION MEASURES m WARNING: In the case of leaf longer than 2 metres, an
electric lock must be fitted to ensure an efficent closing
To carry out a proper installation of the operator parts as well as
to ensure the best automation performance, the
measurement levels shown in the following table shall be
complied with. Change the gate structure to adapt it to one of
the cases in the table, if necessary.
ENGLISH
• For the installations OPENING TOWARDS THE INSIDE, refer to
the table at page 62-63
• For the installations OPENING TOWARDS THE OUTSIDE, refer
to the table at page 64-65
ACTUATOR FIXING
Choose measures referring to the table you can find in the
previous page, mark them on the pillars and continue as follows:
• Fix the clamps to the pillar and to the gate soldering directly;
if the material does not allow it, it is necessary to solder the A
clamps to plates to be fixed to the gate and the pillars by
screws.
• Close the swing.
• Unlock the actuators.
• Position CALYPSO on the brackets and fix the pins no. 1 and
no. 2 with seeger (see the picture).
• Open and close the swings repeatedly manually to verify the
absence of frictions between gate and ground.
556 mm (CALYPSO500)
625 mm (CALYPSO600)
• The minimum stroke of arm B must be more than 56 mm (in
case of gate completely open).
- 11 -
ELECTRICAL CONNECTIONS
ENGLISH
EMERGENCY RELEASE
In case of a blackout, the gate can be operated directly from the
motor. Insert the key supplied in the lock, perform 1/2 of a turn.
To restore the automation, simply rotate the key in closed position
and insert the provided plastic cover onto the lock.