CL-EN
CL-EN
■ Important Notice
・ From V3.10, it was made possible to use a USB memory to also update the Dante module
firmware.
・ Although the CL series firmware (main/sub) can be updated together at the same time by using
the USB memory to update the Dante module firmware, updating the Dante firmware will take
approximately 30 minutes.
・ Although using a computer (Dante Firmware Update Manager) to update the Dante firmware in
the conventional manner reduces the amount of time required for the Dante firmware update, it
is necessary to update the CL series firmware by using a USB memory separately.
・ The following dialog box is displayed after startup if the version of the NAME SUB CPU is old. As it is
necessary to update the NAME SUB CPU, copy the necessary file to the USB memory and perform the
update procedures.
1. Save the CL internal data to the USB memory or CL Editor (compatible with the current firmware
version) as backup.
If you are saving the data to the USB memory, open the SAVE/LOAD popup window from the SETUP screen.
in the DANTE SETUP popup screen, and change it if necessary, after the update is complete and before
reconnecting the cables. Otherwise the Dante network may not function correctly.
4. Connect the USB memory (formatted in FAT12/FAT16/FAT32) to the USB connector of your computer.
5. Copy the all files (extensions .PGM and .BIN) in the "CL_firm***_USB" (*** indicates the version
number) folder extracted from the downloaded file to the root directory of the USB memory.
If you have never updated to V1.70 or later:
As you must update the NAME SUB CPU, copy CL-MD***.BIN (*** indicates the version number) in the
product name and *** the version number) in the Dante\DanteFirmware folder to the root directory of the USB
memory. You can also update the specific firmware by copying the corresponding file into the root directory.
6. Remove the USB memory when the files have been copied.
For more information on removing the USB memory, refer to the owner's manual for your computer and USB
memory.
7. Connect the USB memory to the CL USB connector, then turn on the power to the CL series.
A "Start Loading ?" message will be displayed.
9. When the firmware has been loaded, the CL series automatically restarts and a "Starting System..."
message flashes for approximately one minute.
While this message is flashing, do not turn off the power. If you have accidentally turned off the power, turn on the
・ If CL-MD***.BIN (*** indicates the version number) has already been copied into the root directory of the
USB memory at this time, it will be transferred to the NAME SUB CPU firmware update. Refer to "Updating
the CL NAME SUB CPU Firmware".
・ Similarly, if FWUpdate_CL?_v*****_sw***.dnt (? indicates the product name and *** the version number)
has already been copied into the root directory of the USB memory, it will be transferred to the Dante
firmware update. Refer to "Updating the Dante Firmware".
10. When a "Console initialized due to memory mismatch.” popup window (or similar message) appears,
press the CLOSE button to close it.
・Since it is a message about initialization even if displayed as an error, please continue update.
11. When an "Initialize All Memories ?" message appears, press the INITIALIZE button.
12. When an "Are you sure ?" message appears, press the OK button.
Initializing the internal memory will be started. When you initialize, SECONDARY PORT settings will be DAISY
CHAIN.
14. Remove the USB memory after confirming the ACCESS indicator has disappeared in the function
access area.
15. If necessary, confirm the firmware was correctly updated in the version field in the SETUP screen.
・ Updating is not necessary if the number displayed in ① is larger than or equal to the number displayed in
②.
During this time, NAME SUB CPU is being overwritten. Do not turn off the power of the CL series. Turning the
power off will cause the NAME SUB CPU to stop functioning and make it necessary to take the CL series to a
service center for repairs.
3. When firmware loading is completed, the message "Name Sub CPU Update Successful" is displayed.
Click the [CLOSE] button.
・ If FWUpdate_CL?_v*****_sw***.dnt (? indicates the product name and *** the version number) has already
been copied into the root directory of the USB memory at this time, it will be transferred to the Dante
firmware update. Refer to "Updating the Dante Firmware".
4. If the message "Please re-start the system" is displayed, remove the USB memory and restart the CL
series.
The update has failed if the message "Name Sub CPU Update Failed! Please contact Yamaha
CL5/CL3/CL1Firmware Update Guide 6
Service" is displayed. Please contact your Yamaha dealer.
・ While the firmware version information is being checked, "????" is displayed in ① and the [OK] button is
disabled. The message "Fetching Current Dante Version" is displayed in the center of the screen.
・ When the firmware version information has been acquired, the version number is displayed in ①. At the
same time, the [OK] button becomes enabled and the message "Fetching Current Dante Version" disappears.
・ If the firmware version information cannot be acquired, the message "Please re-start the system and re-write
firmware using Failsafe Recovery in Dante Firmware Update Manager" is displayed. Perform the Dante
module recovery procedures if this occurs.
・ If any of the following messages are displayed, update the firmware to V3.1 or later.
Dante firmware update is not supported.
Please update the console firmware (sub) to V3.1 or higher first and try again
These messages are displayed for approximately 30 minutes. Click the [CANCEL] button to forcibly exit this
mode.
During this time, do not turn off the power of the CL series.
4. If the message "Please re-start the system" is displayed, remove the USB memory and restart the CL
series.
The Dante module will enter "Failsafe mode" if any of the following messages is displayed.
In such cases, refer to "About Failsafe Mode" and perform the Dante module recovery procedures.
In addition, extract the Dante firmware (extension: .dnt) from the compressed file.
The Dante firmware will not work correctly if the path contains any characters other than single-byte
alphanumeric characters, "-" (hyphen), or "_" (underscore). You must save the firmware update file in
a directory whose name contains only single-byte alphanumeric characters, "-" (hyphen), or "_"
(underscore). (E.g., C:\temp)
CL5/CL3/CL1Firmware Update Guide 9
・ The “Windows Security” dialog box may appear. In such case, click [Install this driver software anyway].
・ You may be prompted to restart the computer after the installation is complete. Before proceeding to update,
restart the computer.
・ When installing the Dante Firmware Update Manager, temporarily disable any running anti-virus software.
2. Click [Manage network connection] or [Change Adapter settings] from the “Tasks” list located in the
left side of “Network and Sharing Center” window, then double-click [Local Area Connection].
The "Local Area Connection Status" dialog box will be displayed.
・The "User Account Control" dialog box may appear. Click [Continue] or [Yes].
・If the "Local Area Connection properties" dialog box appears, skip ahead to step 4.
3. Click [Properties].
The “Local Area Connection properties” dialog box will be displayed.
・The "User Account Control" dialog box may appear. Click [Continue] or [Yes].
・For details of the Dante Firmware Update Manager, refer to “AUD-MAN-Firmware Update Manager" stored in the
compressed file folder.
1. Connect the Dante [PRIMARY] connector on the rear panel of the CL series unit to the Ethernet
connector on the computer using an Ethernet cable.
Be sure to directly connect the computer and the CL series unit, and do not connect any other Dante
device to the computer.
Check that the version number is 1.3.2 or higher from the title bar.
・The "User Account Control" dialog box may appear. Click [Continue] or [Yes].
・The Dante firmware will not work correctly if the path contains any characters other than single-byte
alphanumeric characters, "-" (hyphen), or "_" (underscore). You must save the firmware update file in a
directory whose name contains only single-byte alphanumeric characters, "-" (hyphen), or "_" (underscore). (E.g.,
C:\temp)
Be sure to ensure compatibility of the update files with CL. If update files other than CL are applied, the device
will become inoperable. In general, do not check the [Override Device Matching] option. If this option is left
unchecked, only devices that support the file can be selected, ensuring that updating the device with invalid or
wrong files is prevented.
6. Click [Next].
・In some cases the Windows firewall may be blocking the Dante Firmware Update Manager. Select the [Private
network] check box, and click [Allow access]. Alternatively, in the Windows firewall, click "Allow programs or
functions through the Windows firewall," and if the "fum" checkbox is unselected, select this check box to allow
access.
If the update manager is blocked by the Windows firewall, the "Upgrade Failed" dialog box appears.
・If the CL is not indicated, click [Refresh]. If it is still not indicated, use Dante Controller to check whether the
8. Click [Start].
The update operation will begin.
“Updating(n/m)” appears in the Status field during updating. “Done” is displayed once update is completed.
Update takes 2 to 4 minutes. During the update operation, do not turn off the power to the unit or disconnect the
cable. If update fails due to disconnection of the power cable during the update, or due to other reasons, the device
may become inoperative.
・If update is not completed after 5 minutes, or update failure indication appears, click X at the upper right corner
of Dante Firmware Update Manager to exit the program without turning the CL power off, and restart the
procedure from the step 4. If update still fails, follow the instructions stated in “About Failsafe Mode” to perform
the recovery processing.
3. Connect the Dante [PRIMARY] connector on the rear panel of the CL series unit to the Ethernet
connector on the computer using an Ethernet cable.
In some cases, an error may occur during recovery if you are going through a network switch. Connect the
computer with the CL in a one-to-one connection.
・The "User Account Control" dialog box may appear. Click [Continue] or [Yes].
7. If you see the interface selection screen, select the interface card to connect the Dante device.