FlowPet5G
FlowPet5G
CBB318E-1
Remove the front cover. Lift the circuit board. Replace the battery.
Battery Icon Alarm Icons (up to 2) Information Icon
• Normally off • Normally off • Displays when the current mode is different
• Displays when the battery is low to • Displays when instant flow rate meets alarm conditions from the normal measurement mode
suggest battery replacement (Up to 2 alarm conditions can be configured) • Easy to confirm the current operating mode
GENERAL SPECIFICATIONS
Item Description
LCD display 7-segment, 8-digit with 14mm characters, unit display, low battery alarm, and flow indicator (10-segment)
Lithium battery or external power source
Power source • Lithium battery: 3.6V dedicated battery pack, Battery life: 8 years (varies with operating conditions), Storage life: 10 years
• External power source: 12 to 50VDC±10% (Pulse output: Current capacity 10mA or more, Analog output: Current capacity 30mA or more
Display item Total flow, instantaneous flow rate ([/h] or [/min]), and resettable total flow
Output signal Open collector, Allowable current: 20mA, Max. voltage applied: 30V
Analog output
(for model with a Factored pulse Unfactored pulse
pulse generator)
Pulse width: 1ms, 50ms, 100ms, 250ms Pulse width: 2ms (fixed) 4 to 20mA
Temperature range Fluid temperature: 0 to +120℃ (High temperature service: 0 to +150℃), Ambient temperature: -10 to +60℃
Max. operating pressure 1.18MPa (Flange rating: JIS 10K RF)
Accuracy Oil service: ±0.5% of RD Water service: ±1% of RD
FLOW RANGE
Flow Range for Oil Service
Nominal Flow Range, L/h Pressure Loss (kPa) at Max. Flow Rate
Model Size Kerosene Gas Oil (heavy oil A) Heavy oil Kerosene Heavy oil
mm (Above 0.8mPa•s to 2mPa•s) (Above 2mPa•s to 5mPa•s) (Above 5mPa•s to 200mPa•s) 1.2mPa•s 19mPa•s
A
LS4976-5 20 10 to 800 7 to 800 5 to 800 32 47
B
A
LS5076-5 20 150 to 1600 80 to 2000 50 to 2000 14 40
B
A
LS5276-5 25 300 to 3000 150 to 3800 80 to 3800 13 56
B
A
LS5376-5 40 600 to 5000 300 to 6400 150 to 6400 13 30
B
A
LS5576-5 40 1200 to 11000 600 to 14000 400 to 14000 25 54
B
A
LS5676-5 50 2000 to 20000 1400 to 24000 900 to 24000 27 55
B
OUTLINE DIMENSIONS A
B
82.5
L 75°
t
d . D
P.C
D H
75°
External output cable entry
Register orientation (1m long cable furnished)
adjustable in 15° steps (Covered with a blind plug for models without pulse generator)
(75° upward, 75° downward)
The specification as of November, 2015 is stated in this catalog. Specifications and design are subject to change without notice.