Wind Load of Roof Truss
Wind Load of Roof Truss
00 m
SPACING OF TRUSS 7.50 m
SPAN 7.50 m
LENGTH OF TOP CHORD 7.08 m
NO OF PANEL POINTS 2
SPACING OF PURLIN 2.36 m
SLOPING AREA OF ROOF TRUSS 106.13 sq.m
PLAN AREA OF ROOF TRUSS 56.25 sq.m
NO OF PURLINS 8
SLOPE OF TOP CHORD 58.02 deg
LOAD CALCULATIONS
DEAD LOAD :
SELF WEIGHT OF AC 200.00 N/m2
SELF WEIGHT OF PURLIN 160.00 N/m
LIVE LOAD :
Imposed load on truss -210.48 N/m2
Live load on the truss -7885.13 N
Live load on each panel point -3942.57 N -3.94 KN
Live load on end panel point -1971.28 N -1.97 KN
WIND LOAD :
design wind speed (Vz) 44.00 m/s TABLE 1 IS875 (PART 3)
Vz = Vb × K1× K2×K3xK4
K1 1.00 table 1
K2 1.00 table 2
K3 1.00 cl.5.3.3
K4 1.15
Vz = Vb × K1× K2×K3 xK4 50.60 m/s
Kd 0.9
Ka 0.852
Kc 0.9
Dead load, live load and wind load per panel point are summarized in Table 1.
Load on each
intermediate Load at end
Loads panel point (KN) point (KN)
Dead load (DL) 15.41 7.71
Live load (LL) -3.94 -1.97
Wind load (WL) 56.26 28.13
M= 337.56
kN.m