I700 Weighing Terminal PDF (1)
I700 Weighing Terminal PDF (1)
WWW.PRECIAMOLEN.COM
Metrological characteristics Electronic characteristics
DSD Max. number of records .............................. 300.000. LCD screen, 10.4 inches, 800 x 600 pixels (SVGA),
16.2 million colours, back lit. I 700-S Stainless steel case
Analogue measuring interface
Resistive touch pad. Standard equipment
Input per division ............................................................. 0.5 μV • One USB 2 port, for USB memory stick provided (type A sealed
ATOM Intel processor, 1.6 Ghz. connector)
Number of divisions ..................................................... 200.000 • DSD (Data Storage Device)
Static disk capacity: 4 Go.
(Outside legal metrology)
RAM: 1 Go. Options
Load cell connection:
• Nominal power supply .......................................... 5 V DC Operating system: Windows Embedded Standard. Measurement
• Sensitivity ......................................................................... 2 mV/V • 1 to 2 analogue or numerical internal scales, PMNet (sealed output on
WWW.PRECIAMOLEN.COM
Input/Output card option PE, spring type)
• Cabling ................................................................................. Screened 4/6 core • Extension for up to 31 external scales on CAN bus
• Minimum impedance ............................................. 58 6 voltage-free logical inputs including one analogue input and
• Maximum impedance ............................................ 1 245 one multi-function input (watchdog, filtration or rapid I 700 - S USB port
• Maximum cable length ......................................... 150 m counting): • 1 to 4 USB 2 port(s) (type A sealed connector)
(0.68 mm²) • Input impedance ......................................................... 7.5 k Serial link
• Connection ....................................................................... Push-in terminals • Input voltage ................................................................... 6 - 30 V dc • 1 to 3 serial RS port(s) 232, RS 422 or 485 (Din 8 pts, sealed)
• Minimum dead load signal ................................. 0 mV
6 isolated logical outputs:
• Maximum effective signal ................................. 12 mV Ethernet
• Max. current ..................................................................... 125 mA
• 1 to 2 port(s) Ethernet 100 Mbits, (sealed PE output, 10 m cable
Number of measurements available • Max. voltage ..................................................................... 48 V dc
I 700 - C
supplied with RJ 45 connector)
per second ............................................................................ 7 to 120 • Ron ............................................................................................. 25
Go/no-go and 4-20 mA inputs/outputs
Adjustable filter settings
1 analogue output 4-20 mA (weight information or any other General description • 1 to 2 internal cards, each comprising:
information transmitted via the field bus). - 6 numerical inputs/6 numerical outputs
Digital measuring interface (Pmnet) - One 4 - 20mA analogue output
• Impedance ........................................................................ 50 - 350 The I 700 is a freely programmable weighing terminal combining the
performances of a PC type micro-computer with the characteristics of a • Other Input / Output available on external CAN bus
ML HML weight indicator approved for non-automatic or automatic weighing
Accuracy class (ML only) III or IIII -
Maximum number of steps:
Metrological approval instruments. Other
• External AZERTY or QWERTY keyboard
Class III 10.000 30.000 Its colour graphic touch screen provides unique ergonomics for industrial • Barcode scanner
Compliant with the European Directive relative to Non Auto- weighing equipment.
Class IIII 1.000 - matic Weighing Instruments (NAWI).
Supply voltage 24 V dc Mechanical accessories
6.000 range (mono or bi-range) and 3.000 range (multi- Its operating system, Windows Embedded Standard, allows the I 700
Maximum number of ranges 2 - terminal to be used as a production tool, which can be easily integrated • Table base
range). within the company's IT architecture. • Wall mounting
Load impedance
Number of physical channels 1 Compliant with the MID European Directive relative to Auto-
The use of a full scale data base ensures integrity and performances
Number of channels 1 matic Weighing Instruments (AWI) rarely found on this type of device. I 700-C Rack mounting
Max. number of load cells per channel 12 • Checkweighers: classes XIII(1) and Y(a).
The I 700 terminal is extremely modular, enabling adaption to the require- Standard equipment
Pi error distribution factor 0 • Continuous totalisers (dynamic weighing): classes 0.5 and 1. ments of the workstation and future developments:
• Discontinuous totalisers (static weighing): classes 0.25, 0.5, • Management of 1 to 31 scales with analogue or digital sensors • 4 USB 2 ports (type A connectors)
Environmental characteristics 1 and 2. • High capacity static hard disk • 2 Ethernet 100 Mbits ports (RJ45 connectors)
• Serial ports • 3 serial RS ports 232, RS 422 or 485 (Sub D 9 pts M)
Temperature range: • USB sticks • DSD (Data Storage Device)
• Operation ........................................................................... - 10 °C / + 40 Conformity • Analogue outputs Options
• Logical I/O
• Storage ................................................................................ - 20 °C / + 60 • Ethernet ports
Compliant with European Directive relative to Electromag- Measurement
• Sealing (stainless steel case) ......................... IP 66 netic Compatibility. • ...
• 1 to 2 analog or numerical scales, PMNet (spring type)
• Sealing (rack mounting) ...................................... IP 20 (IP65 front
Compliant with European Directive relative to Low Voltage For more rapid data input, the I 700 terminal may be equipped with a PC • extension for up to 31 external scales on CAN bus
panel) type external keyboard and a bar code scanner.
equipments.
Go/no-go and 4-20 mA inputs/outputs
Electrical characteristics The I 700 terminal is equipped with a library of professional applications: • 1 to 2 cards, each comprising:
Labelling group - 6 numerical inputs/6 numerical outputs
Power supply: - One 4 - 20mA analog output
Checking prepacked statistics
• Mains voltage.................................................................. 230 V ± 10% • Other Input / Output available on external CAN bus
Manual formulation / weighing unit
• Frequency ......................................................................... 50 Hz ± 2%
... Other
• Power consumption ................................................ 150 VA max.
• Sealed USB 2 connector to be integrated in the cabinet front (USB
and specific applications may be developed by us in line with your speci- memory stick supplied)
fications. • External AZERTY or QWERTY keyboard
• Barcode scanner
Available models
04-40-00-1 FT B - 06/2016
Your specialist Illustrations are not contractual. Precia-Molen reserves the right to alter the characteristics of the equipment described in this
The I 700 Terminal is available in two versions:
brochure at any time.
I 700 - S: Stainless steel case
PRECIA-MOLEN Headquarters & Factory I 700 - C: Rack mounting
BP 106 - 07000 Privas - France
Tel. 33 (0) 475 664 600
Fax 33 (0) 475 664 330
E-MAIL [email protected]
WWW.PRECIAMOLEN.COM
1. Independent station, two-way transfer of data via a USB stick. 2. I 700 terminals integrated in the company network: transfer
of information from the server to the weighing stations and
recovery of weighing results.
Physical characteristics
Stainless steel casing version
Panel cut-out
in mm
Weight
• Case only: 6 kg approx.
• Wall mounting: 2.5 kg
Panel cut-out
in mm
Mounting bracket
Weight
• Case only: 6 kg approx. Weight
• Table support: 3.9 kg • 5 kg approx.