2021 08 11 LR Final Attendance Report
2021 08 11 LR Final Attendance Report
Working together
For a safer world
Service details
Class recommendation
I have carried out the surveys detailed below. All recommendations made by me have been dealt with to my
satisfaction. I am recommending that class be maintained with new records as follows.
The above recommendation is made subject to any outstanding conditions of class being dealt with as
previously recommended.
1 of 7
CMA CGM TANGER - 9259836 Report Number: 2123469
Date: 10 Aug 2021
2 of 7
CMA CGM TANGER - 9259836 Report Number: 2123469
Date: 10 Aug 2021
Appendices (issued/attached/supplied/included)
Title Number
Appendix 1 - Tasks 5
Appendix 3 - Checklist 7
3 of 7
CMA CGM TANGER - 9259836 Report Number: 2123469
Date: 10 Aug 2021
Attending surveyors
10 Aug 2021
LR Legal entity
Lloyd's Register EMEA
4 of 7
CMA CGM TANGER - 9259836 Report Number: 2123469
Date: 10 Aug 2021
Appendix 1 - Tasks
Table of contents:
Sections Page number
Credit
PUMPING AND VALVE EQUIPMENT GROUP - 1096 THERMAL OIL CIRCULATING PUMP
0415-5TWB6UI-1936 Examine And Test Including Drive Type Complete
Credit
1803 OIL FIRED THERMAL OIL HEATER UNIT - 1872 FRONT OIL BURNING UNIT
0533-D7IIHHQ-2468 Examine Complete
THERMAL TRANSFER EQUIPMENT GROUP - 1803 OIL FIRED THERMAL OIL HEATER UNIT
0534-FCETKVA-2469 Examine And Test In Operation Low Level Fuel Cut Off Complete
Devices
0534-FCETKVA-2476 Examine Mountings And Fittings (Other Than Safety Valve Complete
And Steam Stop Valve)
0534-FCETKVA-2480 Safety Valve Adjustment Under Steam And Verify Records Complete
5 of 7
CMA CGM TANGER - 9259836 Report Number: 2123469
Date: 10 Aug 2021
A: -
Q: Statement received from Chief Engineer that safety valves adjusted at sea to
correct working pressure. Only applies if solely exhaust gas fired
A: -
Q: Add Actionable Item "TOHS (ID No) pressure relief valves set to NN.N bar".
Associate this AI with TOHS service and specify imposed date
A: -
Credit
THERMAL TRANSFER EQUIPMENT GROUP - 1889 EXHAUST GAS THERMAL OIL HEATER UNIT
0534-D53FNMY-2469 Examine And Test In Operation Low Level Fuel Cut Off Complete
Devices
0534-D53FNMY-2476 Examine Mountings And Fittings (Other Than Safety Valve Complete
And Steam Stop Valve)
0534-D53FNMY-2480 Safety Valve Adjustment Under Steam And Verify Records Complete
A: -
Q: Statement received from Chief Engineer that safety valves adjusted at sea to
correct working pressure. Only applies if solely exhaust gas fired
A: -
Q: Add Actionable Item "TOHS (ID No) pressure relief valves set to NN.N bar".
Associate this AI with TOHS service and specify imposed date
A: -
6 of 7
CMA CGM TANGER - 9259836 Report Number: 2123469
Date: 10 Aug 2021
Appendix 3 - Checklist
Lloyd’s Register Group Limited, its subsidiaries and affiliates and their respective officers, employees or agents are, individually and
collectively, referred to in this clause as ‘Lloyd’s Register’. Lloyd’s Register assumes no responsibility and shall not be liable to any person
for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that
person has signed a contract with the relevant Lloyd’s Register entity for the provision of this information or advice and in that case any
responsibility or liability is exclusively on the terms and conditions set out in that contract.