0% found this document useful (0 votes)
8 views

2021 08 11 LR Final Attendance Report

The final attendance report for the CMA CGM TANGER outlines the ship's surveys conducted in Barcelona from August 2 to August 10, 2021, with all recommendations satisfactorily addressed. Class maintenance is recommended, and various certificates have been endorsed with an expiry date of October 31, 2023. The report details specific actions taken regarding conditions of class and actionable items, along with the attending surveyors' information.

Uploaded by

issam elmoharir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
8 views

2021 08 11 LR Final Attendance Report

The final attendance report for the CMA CGM TANGER outlines the ship's surveys conducted in Barcelona from August 2 to August 10, 2021, with all recommendations satisfactorily addressed. Class maintenance is recommended, and various certificates have been endorsed with an expiry date of October 31, 2023. The report details specific actions taken regarding conditions of class and actionable items, along with the attending surveyors' information.

Uploaded by

issam elmoharir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

CMA CGM TANGER - 9259836 Report Number: 2123469

Date: 10 Aug 2021

Working together
For a safer world

Final Attendance Report


Provisional Issue

Service details

Ship name CMA CGM TANGER Location Barcelona (ES)


IMO number 9259836 First visit date 02 Aug 2021
Port of registry Tangier Last visit date 10 Aug 2021
Current flag Morocco

Class recommendation

I have carried out the surveys detailed below. All recommendations made by me have been dealt with to my
satisfaction. I am recommending that class be maintained with new records as follows.

The above recommendation is made subject to any outstanding conditions of class being dealt with as
previously recommended.

Surveys credited in this report

Survey code Survey title Status Credited date Postponed date


AS ANNUAL X 10 Aug 2021 -
ITSS HULL INTERMEDIATE X 10 Aug 2021 -
HRPS Cargo Hold 4B Excessive X 10 Aug 2021 -
Corrosion
HRPS F.O Tank No 32 X 10 Aug 2021 -
CSM CONTINUOUS - MACHINERY P On completion -
TOHS1 THERMAL OIL HEATER X 05 Aug 2021 05 Aug 2021
TOHS2 THERMAL OIL HEATER X 05 Aug 2021 05 Aug 2021
AMSC CARGO HOLD No4 X 10 Aug 2021 -
MOI MARPOL I (OIL) INTERMEDIATE X 10 Aug 2021 -
MAI MARPOL VI (AIR) INTERMEDIATE X 10 Aug 2021 -
SCI SAFCON INTERMEDIATE X 10 Aug 2021 -
SEI SAFETY EQUIPMENT PERIODICAL P On completion -
SEM ECDIS INSTALLATION X 10 Aug 2021 -
DIA DANGEROUS GOODS REG. 19 X 10 Aug 2021 -
ANNUAL
PLI LOAD LINE INSPECTION X 10 Aug 2021 -
RTP RADIOTEL. PERIODICAL X 10 Aug 2021 -
LAAC LIFTING APPLIANCES (ILO 152) X 10 Aug 2021 -
ANNUAL
HMA INVENTORY OF HAZARDOUS X 10 Aug 2021 -
MATERIALS ANNUAL

1 of 7
CMA CGM TANGER - 9259836 Report Number: 2123469
Date: 10 Aug 2021

Action taken with Certificates

ID Certificate Title Action taken Expiry Date


2012864 Cargo Ship Safety Construction Certificate Endorsed 31 Oct 2023
(Harmonized)
2012864 Cargo Ship Safety Radio Certificate Endorsed 31 Oct 2023
(Harmonized)
2105595 Cert/Doc/Statement of Compliance on Endorsed 31 Oct 2023
Inventory of Hazardous Materials (IHM HKC)
2023897 Document of Compliance - Special Endorsed 31 Oct 2023
Requirements for Ships Carrying Dangerous
Goods
2087818 International Air Pollution Prevention Endorsed 31 Oct 2023
Certificate (Harmonised)
2012864 International Load Line Certificate Endorsed 31 Oct 2023
2050738 International Oil Pollution Prevention Endorsed 31 Oct 2023
Certificate
2105595 Statement of Compliance – EU Ship Recycling Endorsed 31 Oct 2023
Regulation
2105595 Supplement to the Statement/Cert/Doc of Endorsed 31 Oct 2023
Compliance on the Inventory of Hazardous
Materials

Action taken with Conditions of Class

ID Description Action taken Due date


CoC-H-016 CARGO HOLD 4B WITH EXCESSIVE Closed 05 Aug 2021
CORROSION 2ND OUTER STRAKE
STARBOARD. TO BE SPECIALLY EXAMINED
AND DEALT WITH AS NECESSARY BY NEXT
BOTTOM SURVEY MEANTIME REMAINS
SATISFACTORY.
CoC-H-017 Prompt & thorough. F.O TANK No 32 FOUND Closed 05 Aug 2021
HOLED AND WASTED. TO BE REPAIRED TO
THE ATTENDING SURVEYOR SATISFACTION
BY THE DUE DATE. MEANWHILE THE TANK
TO BE OUT OF SERVICE.
CoC-A-015 No.4B CONTAINER HOLD BOTTOM PLATE Closed 31 Jan 2022
FOUND WITH CONCENTARTED DEEP PITTING
BETWEEN FRAMES 62-71 TEMPORARY
REPAIRED BY THE BUILDING UP SURFACE, TO
BE SPECIALLY EXAMINED AND DEALT WITH
AS FOUND NECESSARY TO THE ATTENDING
SURVEYOR SATISFACTION BY THE DUE DATE.

Action taken with Actionable Items

ID Description Action taken Due date


CMQ SCM DESCRIPTIVE NOTE ASSIGNED. RECORDS Amended -
TO BE EXAMINED ANNUALLY AT TIME OF
ANNUAL SURVEY. DETAILS TO BE REPORTED
AT TAILSHAFT SURVEY.
CLI LOADING INSTRUMENT (C) Amended -
AI-C-003 ANNUAL SURVEY OF CONTAINER SECURING Amended -
ARRANGEMENTS TO BE HELD AT DUE TIME
OF AND IN CONJUNCTION WITH THE
ANNUAL CLASSIFICATION
SURVEY.
AI-C-005 SUBSTANTIAL CORROSION IDENTIFIED ON Closed -

2 of 7
CMA CGM TANGER - 9259836 Report Number: 2123469
Date: 10 Aug 2021

NO. 4B CONTAINER HOLD BOTTOM PLATING,


BETWEEN FRS. 62-71 AND BETWEEN HOLD
PORT AND STBD
LONGITUDINAL BULKHEADS. AREA TO
EXAMINED AND GAUGED AS NECESSARY AT
EACH ANNUAL SURVEY.
AI-C-011 AT ANNUAL SURVEY, SURVEYOR TO Amended -
CONFIRM MAINTENANCE OF ASBESTOS
MANAGEMENT PLAN (AMP), UNTIL
REMOVAL OF ASBESTOS IS CONFIRMED NO
LATER THAN < INSERT DATE UP TO 3 YEARS
LATER >.
SCE THE RECORD OF EQUIPMENT FOR CARGO Closed -
SHIP SAFETY, FORM E (FORM 2211) IS TO BE
REISSUED, UPDATING SECTION 3, ITEM 3.1
(SEE RESOLUTION MSC.421(98)), NOT LATER
THAN THE NEXT RENEWAL SURVEY CARRIED
OUT ON OR AFTER 1 JANUARY 2020.
ON COMPLETION, THIS ACTIONABLE ITEM IS
TO BE CLOSED.
AI-C-013 FOLLOWING CONNECTING BRACKETS Amended -
BETWEEN UNDER VOID SPACE DECK
TRANSVERSE STIFFENER AND SIDE SHELL
NON CONTINUOUS FRAME FOUND WITH
LOCALISED WASTAGE AT CONNECTION. TO
BE KEEP UNDER OBSERVATION BY CREW
AND RECORDS TO BE EXAMINED AT EACH
ANNUAL SURVEY.
- WBT 24 PORT FRAMES: 64, 65, 67, 69 AND
70
- WBT 20 PORT FRAMES: 83, 84, 85, 88 AND
91

Appendices (issued/attached/supplied/included)

Title Number
Appendix 1 - Tasks 5
Appendix 3 - Checklist 7

3 of 7
CMA CGM TANGER - 9259836 Report Number: 2123469
Date: 10 Aug 2021

Attending surveyors

Attending surveyor name Lead surveyor


Manuel Alonso Yes
Felix Enrique Carrasco

Issuing surveyor signature Manuel Alonso


Cádiz (Barcelona Port) Office Signed date
Lloyd's Register EMEA
LR031.1.2016.06

10 Aug 2021

Issuing surveyor name


Manuel Alonso

LR Legal entity
Lloyd's Register EMEA

4 of 7
CMA CGM TANGER - 9259836 Report Number: 2123469
Date: 10 Aug 2021

Appendix 1 - Tasks

Table of contents:
Sections Page number

1. Tasks credited for Machinery 5

1. Tasks credited for Machinery

Credit

CSM CONTINUOUS - MACHINERY

17 INLINE TRUNK ENGINE - 279 NO.4 FUEL INJECTION PUMP


0230-WCZ3Q5Q-949 Examine Complete

THERMAL TRANSFER EQUIPMENT GROUP - 729 L.O. PURIFIER HEATER


0336-GA6EV6Q-1748 Examine And Test Complete

PUMPING AND VALVE EQUIPMENT GROUP - 1096 THERMAL OIL CIRCULATING PUMP
0415-5TWB6UI-1936 Examine And Test Including Drive Type Complete

Credit

TOHS1 THERMAL OIL HEATER

1803 OIL FIRED THERMAL OIL HEATER UNIT - 1872 FRONT OIL BURNING UNIT
0533-D7IIHHQ-2468 Examine Complete

THERMAL TRANSFER EQUIPMENT GROUP - 1803 OIL FIRED THERMAL OIL HEATER UNIT
0534-FCETKVA-2469 Examine And Test In Operation Low Level Fuel Cut Off Complete
Devices

0534-FCETKVA-2470 Examine Combustion Equipment In Operation Complete

0534-FCETKVA-2471 Examine Externally Complete

0534-FCETKVA-2472 Examine Fire Side (Structure And Securing Arrangements) Complete

0534-FCETKVA-2473 Examine Heater Unit Controls (including Remote Control) In Complete


Operation

0534-FCETKVA-2474 Examine In Operation Including Ancillary Equipment Complete

0534-FCETKVA-2475 Examine Internally (And Check Fit Of Doors) Complete

0534-FCETKVA-2476 Examine Mountings And Fittings (Other Than Safety Valve Complete
And Steam Stop Valve)

0534-FCETKVA-2477 Examine Tubes And Headers Or Drums Complete

0534-FCETKVA-2478 Functional Test Of Alarms And Safeguards Complete

0534-FCETKVA-2479 Review Of Circulating Oil Analysis Record Complete

0534-FCETKVA-2480 Safety Valve Adjustment Under Steam And Verify Records Complete

5 of 7
CMA CGM TANGER - 9259836 Report Number: 2123469
Date: 10 Aug 2021

Q: Report pressure to which safety valves were adjusted

A: -

Q: Statement received from Chief Engineer that safety valves adjusted at sea to
correct working pressure. Only applies if solely exhaust gas fired

A: -

Q: Add Actionable Item "TOHS (ID No) pressure relief valves set to NN.N bar".
Associate this AI with TOHS service and specify imposed date

A: -

Credit

TOHS2 THERMAL OIL HEATER

THERMAL TRANSFER EQUIPMENT GROUP - 1889 EXHAUST GAS THERMAL OIL HEATER UNIT
0534-D53FNMY-2469 Examine And Test In Operation Low Level Fuel Cut Off Complete
Devices

0534-D53FNMY-2470 Examine Combustion Equipment In Operation Complete

0534-D53FNMY-2471 Examine Externally Complete

0534-D53FNMY-2472 Examine Fire Side (Structure And Securing Arrangements) Complete

0534-D53FNMY-2473 Examine Heater Unit Controls (including Remote Control) In Complete


Operation

0534-D53FNMY-2474 Examine In Operation Including Ancillary Equipment Complete

0534-D53FNMY-2475 Examine Internally (And Check Fit Of Doors) Complete

0534-D53FNMY-2476 Examine Mountings And Fittings (Other Than Safety Valve Complete
And Steam Stop Valve)

0534-D53FNMY-2477 Examine Tubes And Headers Or Drums Complete

0534-D53FNMY-2478 Functional Test Of Alarms And Safeguards Complete

0534-D53FNMY-2479 Review Of Circulating Oil Analysis Record Complete

0534-D53FNMY-2480 Safety Valve Adjustment Under Steam And Verify Records Complete

Q: Report pressure to which safety valves were adjusted

A: -

Q: Statement received from Chief Engineer that safety valves adjusted at sea to
correct working pressure. Only applies if solely exhaust gas fired

A: -

Q: Add Actionable Item "TOHS (ID No) pressure relief valves set to NN.N bar".
Associate this AI with TOHS service and specify imposed date

A: -

6 of 7
CMA CGM TANGER - 9259836 Report Number: 2123469
Date: 10 Aug 2021

Appendix 3 - Checklist

Checklist items outstanding

Survey code Checklist item ID Checklist item description


SEI A011200 Voyage Data Recorder (VDR/S-VDR) checklist completed and (if possible)
Certificate of Compliance confirmed on board (if not on board at time of
survey, Master to be advised that the Certificate of Compliance is to be
provided on board) (SOLAS regs. V/18.8 and 20) (MSC.1/Circ.1222/Rev.1)

Lloyd’s Register Group Limited, its subsidiaries and affiliates and their respective officers, employees or agents are, individually and
collectively, referred to in this clause as ‘Lloyd’s Register’. Lloyd’s Register assumes no responsibility and shall not be liable to any person
for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that
person has signed a contract with the relevant Lloyd’s Register entity for the provision of this information or advice and in that case any
responsibility or liability is exclusively on the terms and conditions set out in that contract.

7 of 7

You might also like