VAF39A-1_Datasheet

The VAF39A-1 is a digital 3-phase meter that measures voltage, current, frequency, RPM, and run hours with programmable CT/PT settings. It features a 3-row LED display, operates within a temperature range of -10ºC to +55ºC, and complies with various EMI/EMC standards. The device is suitable for panel mounting and is available in different supply voltage options.

Uploaded by

rajnish tiwari
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views

VAF39A-1_Datasheet

The VAF39A-1 is a digital 3-phase meter that measures voltage, current, frequency, RPM, and run hours with programmable CT/PT settings. It features a 3-row LED display, operates within a temperature range of -10ºC to +55ºC, and complies with various EMI/EMC standards. The device is suitable for panel mounting and is available in different supply voltage options.

Uploaded by

rajnish tiwari
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

VAF Meters - Digital VAF39A-1

Features :
3Ø (True RMS) Voltage
3Ø (True RMS) Current
Frequency
Run hour (Hour - Mins)
RPM
Programmable CT/PT Primary/Secondary

Certifications :
96 x 96 mm

Technical specifications
Display specifications
Display 3 Rows, LED Display
Digit 3
Digit height 0.58" (14.7 mm)
Input specifications
Electrical connection 3Ø-4W, 3Ø-3W, 2Ø-3W, 1Ø-2W
Input voltage rated 11 to 300V AC, (Phase to neutral), 19 to 519V AC, (Phase to phase)
Input current rated Nominal 5A (Min-30mA, Max-6A)
Frequency 50 or 60 Hz
Display scrolling Automatic / Manual (Programmable)
RPM 1350 - 1950 [Pole: 0 (Range: 0 - 98, Selectable in steps of 2), Frequency: 45 - 65Hz]
Resolution Current & voltage: Depending on CT & PT RPM: 0.1, Run Hour: 0.1hr
Voltage(L-N/L-L): ±0.5% of F.S. ±2 digit
Average Voltage (L-N / L-L): ±0.5% of F.S. ±2 digit
Current: ±1% of F.S. ±2 digit
Accuracy Average current: ±1% of F.S. ±2 digit
Frequency: ±0.1Hz ±1digit
Run Hour: ±1%
RPM: ±0.5%
1) 3Ø Voltage (L-N, L-L, Avg.)
2) 3Ø Current (I1, I2, I3, Avg.)
Measurements 3) Frequency
4) RPM
5) Run hour
Supply specifications
Auxiliary supply 230V AC, ±20% (50/60Hz), 110V AC, ±20% (50/60Hz)
Burden 0.5VA @ 5A Per phase
Settable Parameters
CT Primary 5A to 10,000A (Programmable for any value)
CT Secondary 1A/5A (Programmable)
PT Primary 100V to 500kV (Programmable for any value)
PT Secondary 100 to 500V AC (L-L) (Programmable for any value)
Environment specifications
Operating: -10ºC to +55ºC
Temperature
Storage: -20ºC to +75ºC
Humidity (Non - condensing) Upto 85% RH

www.selec.com 1
VAF Meters - Digital VAF39A-1

Mechanical specifications
Mounting Panel mount
Weight 344gm

Terminal connections Dimensions (All are in mm)


N
L

91.5mm
90.5mm
99mm
L1 L
L2 O
99mm 5mm 50mm 91.5mm
L3 A
Front bezel Side view Panel cutout
N D

S1 S2 S1 S2 S1 S2 N V1 V2 V3
I1 I2 I3

Standards compliance Ordering information


Applicable EMI / EMC Standards Product code Supply voltage Certification
Product standard : IEC 61326 - 1 VAF39A-1-230V AC-CE 230V AC
Category Standards Compliance VAF39A-110V-CU 110V AC
Level IV (Air discharge : 8kV),
ESD Immunity IEC 61000 - 4 - 2 (Contact discharge : 4kV)
+ / - 2kV Common mode,
Surge immunity IEC 61000 - 4 - 5 (Line to ground)
Level III, 80 to 1000MHz
(10V / m)
Radiated Level II, 1.4GHz to 2GHz
susceptibility IEC 61000 - 4 - 3
(3V / m)
Level I, 2GHz to 2.7GHz
(1V / m)
Conducted
IEC 61000 - 4 - 6 Level II (3V / m)
susceptibility
Dips : 0% Residual voltage /
1 Cycle (Criteria B), 40%
Residual voltage / 10 Cycles
50Hz / 12 Cycles 60Hz
Voltage dips and
IEC 61000 - 4 - 11 (Criteria C), 70% Residual
interruptions voltage / 25 cycles 50Hz /
30 Cycles 60Hz (Criteria C)
Interruptions : 0% Residual
voltage / 250 Cycles 50Hz /
300 Cycles 60Hz(Criteria C)

Conducted emission CISPR - 11


Radiated emission CISPR - 11
Electrical fast Level III (2kV)
IEC 61000 - 4 - 4
transient

www.selec.com 2