Installation Sheet
Z
Y
All commands are triggered by a brief connection of the Fault trigger distance C −3 mm ±1 mm −4 mm ±2 mm
command wire to the zero potential (“contact ground”). Mounted on ferromagnetic material
Approach distance A 17 mm ±4 mm 28 mm ±7 mm
Figure 8: Overview of learning phases
Break distance B 21 mm ±4 mm 38 mm ±5 mm
Fault trigger distance C −3 mm ±1 mm −4 mm ±2 mm
Detector Reset
Default State: LED off
See Figure 4. The values refer to the Y-distance relative to the learning
position. Values along the Z-axis may differ. If required they are to be
Learn-In Environment determined separately. The distances may vary depending on the
Indication: Red
installation situation, the magnetic code and the learning distance.
Before the device is brought into service, they are to be verified.
Temporarily disconnect
Environment Learnt-In Reset Detector
Power Supply LED off Indication: Orange
(*) These operating distances are reached with a learning distance of
LED off
15 mm (y axis) with a tolerance of ±5 mm (x axis) between the detector
and the magnet housing.
Learn-In Magnet
Indication: Green