Smart Engineering Solutions presents an offer for a grid-connected PV system with a generator output of 460.9 kWp, utilizing 838 PV modules and 4 inverters. The system is projected to produce approximately 699,905 kWh annually, avoiding 328,939 kg of CO₂ emissions per year. Detailed data on module areas, inverter configurations, and energy balance calculations are included in the proposal.

Uploaded by

mahmoud2338858
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views12 pages

Moneer 2 1st Version

Smart Engineering Solutions presents an offer for a grid-connected PV system with a generator output of 460.9 kWp, utilizing 838 PV modules and 4 inverters. The system is projected to produce approximately 699,905 kWh annually, avoiding 328,939 kg of CO₂ emissions per year. Detailed data on module areas, inverter configurations, and energy balance calculations are included in the proposal.

Uploaded by

mahmoud2338858
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Smart Engineering Solutions

8 Makram Abeid, Nasr City


Cairo
Egypt

Contact person:
SES
Phone: +201000792722
E-Mail: [email protected]

Offer no.: 01

9/6/2023

Your PV system from Smart Engineering Solutions


Address of Installation

Created with PV*SOL premium 2023 (R1)


Valentin Software GmbH
Smart Engineering Solutions
Offer Number: 01

Project Overview

Figure: Overview Image, 3D Design

PV System
3D, Grid-connected PV System
Climate Data Madinet Shbin El Koom, EGY (1996 -
2015)
Values source Meteonorm 8.1(i)
PV Generator Output 460.9 kWp
PV Generator Surface 2,164.8 m²
Number of PV Modules 838
Number of Inverters 4

Page 2 of 12
Created with PV*SOL premium 2023 (R1)
Valentin Software GmbH
Smart Engineering Solutions
Offer Number: 01

Figure: Schematic diagram

Production Forecast
Production Forecast
PV Generator Output 460.90 kWp
Spec. Annual Yield 1,518.48 kWh/kWp
Performance Ratio (PR) 82.76 %
Yield Reduction due to Shading 2.2 %

Grid Feed-in 699,905 kWh/Year


Grid Feed-in in the first year (incl. module degradation) 691,441 kWh/Year
Standby Consumption (Inverter) 35 kWh/Year

CO₂ Emissions avoided 328,939 kg / year

The results have been calculated with a mathematical model calculation from Valentin Software GmbH (PV*SOL algorithms). The
actual yields from the solar power system may differ as a result of weather variations, the efficiency of the modules and inverter,
and other factors.

Page 3 of 12
Created with PV*SOL premium 2023 (R1)
Valentin Software GmbH
Smart Engineering Solutions
Offer Number: 01

Set-up of the System


Overview
System Data
Type of System 3D, Grid-connected PV System

Climate Data
Location Madinet Shbin El Koom, EGY (1996 - 2015)
Values source Meteonorm 8.1(i)
Resolution of the data 1h
Simulation models used:
- Diffuse Irradiation onto Horizontal Plane Hofmann
- Irradiance onto tilted surface Hay & Davies

Module Areas
1. Module Area - Arbitrary Building 02-Mounting Surface West
PV Generator, 1. Module Area - Arbitrary Building 02-Mounting Surface West
Name Arbitrary Building 02-Mounting
Surface West
PV Modules 432 x JAM72S30-550/MR (v1)
Manufacturer JA Solar Holdings Co., Ltd.
Inclination 5 °
Orientation West 265 °
Installation Type Roof parallel
PV Generator Surface 1,116.0 m²

Figure: 1. Module Area - Arbitrary Building 02-Mounting Surface West

Page 4 of 12
Created with PV*SOL premium 2023 (R1)
Valentin Software GmbH
Smart Engineering Solutions
Offer Number: 01

Degradation of Module, 1. Module Area - Arbitrary Building 02-Mounting Surface West


Characteristic curve Linear (straight line)
Remaining power (power output) after 1 year 98 %
Remaining power (power output) after 20 years 87 %
Remaining power (power output) after 25 years 84 %

Figure: Degradation of Module, 1. Module Area - Arbitrary Building 02-Mounting Surface West

Page 5 of 12
Created with PV*SOL premium 2023 (R1)
Valentin Software GmbH
Smart Engineering Solutions
Offer Number: 01

2. Module Area - Arbitrary Building 05-Mounting Surface East


PV Generator, 2. Module Area - Arbitrary Building 05-Mounting Surface East
Name Arbitrary Building 05-Mounting
Surface East
PV Modules 406 x JAM72S30-550/MR (v1)
Manufacturer JA Solar Holdings Co., Ltd.
Inclination 5 °
Orientation East 85 °
Installation Type Roof parallel
PV Generator Surface 1,048.8 m²

Figure: 2. Module Area - Arbitrary Building 05-Mounting Surface East

Page 6 of 12
Created with PV*SOL premium 2023 (R1)
Valentin Software GmbH
Smart Engineering Solutions
Offer Number: 01

Degradation of Module, 2. Module Area - Arbitrary Building 05-Mounting Surface East


Characteristic curve Linear (straight line)
Remaining power (power output) after 1 year 98 %
Remaining power (power output) after 20 years 87 %
Remaining power (power output) after 25 years 84 %

Figure: Degradation of Module, 2. Module Area - Arbitrary Building 05-Mounting Surface East

Page 7 of 12
Created with PV*SOL premium 2023 (R1)
Valentin Software GmbH
Smart Engineering Solutions
Offer Number: 01

Horizon Line, 3D Design

Figure: Horizon (3D Design)

Inverter configuration
Configuration 1
Module Area Arbitrary Building 02-Mounting Surface West
Inverter 1
Model SG110CX (v2)
Manufacturer Sungrow Power Supply Co., Ltd.
Quantity 2
Sizing Factor 113.7 %
Configuration MPP 1: 2 x 18
MPP 2: 2 x 18
MPP 3: 2 x 18
MPP 4: 1 x 18
MPP 5: 1 x 18
MPP 6: 1 x 18
MPP 7: 1 x 18
MPP 8: 1 x 18
MPP 9: 1 x 18

Page 8 of 12
Created with PV*SOL premium 2023 (R1)
Valentin Software GmbH
Smart Engineering Solutions
Offer Number: 01

Configuration 2
Module Area Arbitrary Building 05-Mounting Surface East
Inverter 1
Model SG110CX (v2)
Manufacturer Sungrow Power Supply Co., Ltd.
Quantity 1
Sizing Factor 102.6 %
Configuration MPP 1: 2 x 18
MPP 2: 2 x 18
MPP 3: 1 x 18
MPP 4: 1 x 18
MPP 5: 1 x 18
MPP 6: 1 x 15
MPP 7: 1 x 18
MPP 8: 1 x 18
MPP 9: 1 x 18
Inverter 2
Model SG110CX (v2)
Manufacturer Sungrow Power Supply Co., Ltd.
Quantity 1
Sizing Factor 111.1 %
Configuration MPP 1: 2 x 18
MPP 2: 2 x 18
MPP 3: 1 x 18
MPP 4: 1 x 18
MPP 5: 2 x 18
MPP 6: 1 x 15
MPP 7: 1 x 16
MPP 8: 1 x 18
MPP 9: 1 x 18

AC Mains
AC Mains
Number of Phases 3
Mains voltage between phase and neutral 230 V
Displacement Power Factor (cos phi) +/- 0.95

Page 9 of 12
Created with PV*SOL premium 2023 (R1)
Valentin Software GmbH
Smart Engineering Solutions
Offer Number: 01

Simulation Results
Results Total System
PV System
PV Generator Output 460.90 kWp
Spec. Annual Yield 1,518.48 kWh/kWp
Performance Ratio (PR) 82.76 %
Yield Reduction due to Shading 2.2 %

Grid Feed-in 699,905 kWh/Year


Grid Feed-in in the first year (incl. module degradation) 691,441 kWh/Year
Standby Consumption (Inverter) 35 kWh/Year

CO₂ Emissions avoided 328,939 kg / year

Figure: Energy flow

Page 10 of 12
Created with PV*SOL premium 2023 (R1)
Valentin Software GmbH
Smart Engineering Solutions
Offer Number: 01

Figure: Production Forecast

Results per Module Area


Arbitrary Building 02-Mounting Surface West
PV Generator Output 237.60 kWp
PV Generator Surface 1,115.96 m²
Global Radiation at the Module 1836.96 kWh/m²
Global Radiation on Module without reflection 1838.81 kWh/m²
Performance Ratio (PR) 82.56 %
PV Generator Energy (AC grid) 360786.82 kWh/Year
Spec. Annual Yield 1518.46 kWh/kWp

Arbitrary Building 05-Mounting Surface East


PV Generator Output 223.30 kWp
PV Generator Surface 1,048.80 m²
Global Radiation at the Module 1827.99 kWh/m²
Global Radiation on Module without reflection 1829.85 kWh/m²
Performance Ratio (PR) 82.98 %
PV Generator Energy (AC grid) 339118.10 kWh/Year
Spec. Annual Yield 1518.67 kWh/kWp

Page 11 of 12
Created with PV*SOL premium 2023 (R1)
Valentin Software GmbH
Smart Engineering Solutions
Offer Number: 01

PV System Energy Balance


PV System Energy Balance
Global radiation - horizontal 1,864.05 kWh/m²
Deviation from standard spectrum -18.64 kWh/m² -1.00 %
Ground Reflection (Albedo) 0.70 kWh/m² 0.04 %
Orientation and inclination of the module surface -5.77 kWh/m² -0.31 %
Module-independent shading -5.87 kWh/m² -0.32 %
Reflection on the Module Interface -1.86 kWh/m² -0.10 %
Global Radiation at the Module 1,832.61 kWh/m²

1,832.61 kWh/m²
x 2164.765 m²
= 3,967,177.38 kWh

Global PV Radiation 3,967,177.38 kWh


Soiling -198,344.28 kWh -5.00 %
STC Conversion (Rated Efficiency of Module 21.29 %) -2,966,271.64 kWh -78.71 %
Rated PV Energy 802,561.46 kWh
Module-specific Partial Shading -11,061.85 kWh -1.38 %
Low-light performance 4,547.14 kWh 0.57 %
Deviation from the nominal module temperature -50,805.59 kWh -6.38 %
Diodes -327.17 kWh -0.04 %
Mismatch (Manufacturer Information) -14,898.28 kWh -2.00 %
Mismatch (Configuration/Shading) -3,311.28 kWh -0.45 %
PV Energy (DC) without inverter down-regulation 726,704.44 kWh
Failing to reach the DC start output 0.00 kWh 0.00 %
Down-regulation on account of the MPP Voltage Range -0.04 kWh 0.00 %
Down-regulation on account of the max. DC Current 0.00 kWh 0.00 %
Down-regulation on account of the max. DC Power 0.00 kWh 0.00 %
Down-regulation on account of the max. AC Power/cos phi 0.00 kWh 0.00 %
MPP Matching -35.22 kWh 0.00 %
PV energy (DC) 726,669.19 kWh

Energy at the Inverter Input 726,669.19 kWh


Input voltage deviates from rated voltage -144.01 kWh -0.02 %
DC/AC Conversion -12,336.48 kWh -1.70 %
Standby Consumption (Inverter) -35.40 kWh 0.00 %
Total Cable Losses -14,283.77 kWh -2.00 %
PV energy (AC) minus standby use 699,869.52 kWh
PV Generator Energy (AC grid) 699,904.92 kWh

Page 12 of 12
Created with PV*SOL premium 2023 (R1)