0% found this document useful (0 votes)
56 views2 pages

P3007 Installation Guide: Parts Technical Specification

The document provides technical specifications for a display unit, including details on resolution, brightness, power consumption, and environmental ratings. It outlines electrical requirements, interface connectivity options, and physical dimensions. Additionally, it includes information on connectors, grounding, and digital/analog inputs for integration with other systems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views2 pages

P3007 Installation Guide: Parts Technical Specification

The document provides technical specifications for a display unit, including details on resolution, brightness, power consumption, and environmental ratings. It outlines electrical requirements, interface connectivity options, and physical dimensions. Additionally, it includes information on connectors, grounding, and digital/analog inputs for integration with other systems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Technical specification Parts

Display A B C
Resolution 800 x 480 Inst
Installation

ENGL
Installation Ma

ISH
ENGL
Installation Manual

ISH
ENGL
alla Manua

ISH
tion nual

ENGL
ISH
Ma l
nua
l

Brightness >1200 nits

ban
dg.
com com com com
ban ban ban
dg. dg. dg.
Touch screen Full touch screen (multi-touch)
Viewing angles Left/right: 70°, top: 50°, bottom: 60° D E F
P3007
Electrical
Supply voltage 12/24 V DC (9.0 - 31.2 V DC min - max)
Installation Guide
G H
680 mA/ 330 mA at 12 V DC (backlight full/off )
Power consumption
380 mA/200 mA at 24 V DC (backlight full/off )
Recommended fuse rating (12 V / 24 V) 3A
Environmental
Temperature range -15°C to +55°C (5°F to 131°F) A. P3007 unit
Storage temperature -20°C to +60°C (4°F to 140°F) B. Panel mounting kit
Waterproof rating IPX2 C. Documentation
Category Protected D. Power cable
Shock, vibration and humidity According to IEC 60945 E. Communication cable
Interface/Connectivity F. Fuse kit
Ethernet 1x (RJ45) 100Base-TXS, 8P8C connector, IPv4 G. Bracket kit
Lightweight Ethernet protocol IEE 802.3
H. Suncover (sold separately)
Maximum data rate 450 sps addressed to device, 500 sps unintended *988-12389-003*
Buffer capacity Dynamic serial buffer
NMEA 2000 1x (Micro-C ,1 LEN)
Data card reader 1x slot (microSD)
Comms System examples
IEC 61162-2 ports 2x
Digital input 1x GPS GPS GPS
Analog input 1x
Power output (+16 V DC, 70 mA) 1x
Datagram types NkPgN and UdPbC
Physical P2005 / P3007 P2005 / P3007 P2005 / P3007
T BACKLIGHT
Compass Safe Distance - Metric, imperial 0.9 m (2.95 ft) MOB KEY CONTROL SPEED
Weight (display only) 1.32 kg (2.91 lbs)

Bracket mounting Dimensional drawings


220.0 mm 174.0 mm T
(8.66”) (6.85”) T
197.0 mm 8.0 mm 74.7 mm
(7.76”) (0.32”) (2.94”)
141.0 mm
154.9 mm

(5.56”)

MX JUNCTION BOX
(6.10”)

T
ANALOG
CAN BUS CAN BUS CAN BUS NMEA 0183/
DIGITAL ETHERNET
TERMINATOR BACKBONE DROP CABLES IEC 61162-1/-2
202.2 mm 61.9 mm FREQUENCY
(7.96”) (2.44”)
Connector overview Communication cable
A. NMEA 2000, Micro-C connector Refer to the Operator Manual for software setup. Wiring illustrations only include the required wires for the example.
B. Ethernet, RJ45 connector
IEC 61162-2 port 1 RX: 6, 5, 4, Drain N.C
C. Power and external alarm, 4-pin connector IEC 61162-2 port 1 TX: 10, 17, 18, 19 12 1
D. Ground, M4 threaded insert 11 2
13 14
IEC 61162-2 port 2 TX: 3, 16, 15, 19 10 3
E. Comms (communication), 19-pin connector 18 19 15 Cable plug
A B C D E 9
17 16
4
8 5
IEC 61162-2 port 2 RX: 7, 8, 9, Drain N.C 7 6

Digital/Analog: 1, 13, 12, 11, 2, 14


IEC 61162-2

Power and external alarm Pin/Wire Color IEC 61162-2 port 1 Pin/Wire Color IEC 61162-2 port 2
10 black TX common 3 black/red TX common
A. DC negative - black E. Power failure alarm output (N/C isolated
contact) - yellow A B 17 white talker (TX_A) 16 white/red talker (TX_A)
B. +12/24 V DC - red
18 brown talker (TX_B) 15 brown/red talker (TX_B)
F. Alert management system
C. Fuse (3 A) C 19 drain (gray shrink tube) TX drain 19 drain (blue shrink tube) TX drain
D. Power failure alarm output D E 7 black/white RX common 6 brown/red RX common
(contact return) - blue F 8 yellow listener (RX_A) 5 yellow/red listener (RX_A)
9 green listener (RX_B) 4 green/red listener (RX_B)
¼ Note: Refer to the technical specification for electrical details. N.C drain (purple shrink tube) RX drain N.C drain (orange shrink tube) RX drain

Direct antenna connection


IEC 61162-2 port 1 GPS antenna IEC 61162-2 port 2 GPS antenna
8 GPS primary output (TX_A) 4 GPS secondary output (TX_B)
Ethernet NMEA 2000 9 GPS primary output (TX_B) 5 GPS secondary output (TX_A)
The unit is equipped with a standard RJ-45 connector. The unit is equipped with a standard Micro-C connector. 17 GPS control input (RX_A)
18 GPS control input (RX_B)
¼ Note: Network switches can be used to extend the
network. Routers and repeater hubs shall not be used. Analog input
The analog port can be configured for backlight control.
Network traffic filtering by external managed switch
supports IGMP version 2. Pin/wire Color Backlight control A. Potentiometer (10 k - 100 k Ohm, 0.1 W)
2 red +16 V DC (max. 70 mA) 2 11 A
11 blue/white signal in
12 blue/red not used
Grounding 13 gray/orange ground 13
14 drain (clear shrink tube) not used
A. Ground, M4 threaded insert A
B. Grounding cable, min. 0.82 mm2 ( 18 AWG)
B C D Digital input
C. Star washer
The digital port can be used for either speed input or as an external MOB key.
D. Screw (M4-.7 X 6 mm)
Pin/wire Color Speed log MOB
1 pink signal in signal in
13 grey/orange ground ground
14 drain (clear shrink tube) not used not used
¼ Note: It is recommended that the unit ground is connected to the vessel’s bonded ground or a non-bonded RF ground.
MOB Speed

A. Momentary push button A speed log that outputs 200 pulses per nautical mile can
be connected to the digital port.
1 A 1
A. Speed log (200 pulses/NM)
For more information on alerts, refer to the Operator manual. A
B. Ship’s ground