0% found this document useful (0 votes)
17 views

Eaton INDGW-M2 User Guide

The UPS Industrial Gateway Card User's Guide provides comprehensive instructions for installing, configuring, and servicing the Network Management Module. It includes detailed sections on accessing the web interface, configuring Modbus settings, cybersecurity considerations, and user permissions. Additionally, the guide covers maintenance procedures and technical specifications for effective management of the device.

Uploaded by

rlatjsekf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views

Eaton INDGW-M2 User Guide

The UPS Industrial Gateway Card User's Guide provides comprehensive instructions for installing, configuring, and servicing the Network Management Module. It includes detailed sections on accessing the web interface, configuring Modbus settings, cybersecurity considerations, and user permissions. Additionally, the guide covers maintenance procedures and technical specifications for effective management of the device.

Uploaded by

rlatjsekf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 297

UPS Industrial Gateway Card

INDGW-M2
User's Guide
English

04/23/2024
NM3_and_eNMC2
Eaton is a registered trademark of Eaton Corporation or its subsidiaries and affiliates.

Phillips and Pozidriv are a registered trademarks of Phillips Screw Company.

National Electrical Code and NEC are registered trademarks of National Fire Protection Association, Inc.

Microsoft®, Windows®, and Windows Server® are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.

UNIX® is a registered trademark of The Open Group.

Linux® is the registered trademark of Linus Torvalds in the U.S. and other countries.

VMware is a registered trademark or trademark of VMware, Inc. in the United States and/or other jurisdictions.

Google™ is a trademark of Google Inc.

All other trademarks are properties of their respective companies.

©Copyright 2019 Eaton Corporation. All rights reserved.

No part of this document may be reproduced in any way without the express written approval of Eaton Corporation.
1 Table of Contents
1 TABLE OF CONTENTS ....................................................................................................................................... 4

2 INSTALLING THE NETWORK MANAGEMENT MODULE ............................................................................... 11


2.1 Overview ............................................................................................................................................................................. 11
2.2 Unpacking the Network module.......................................................................................................................................... 11
2.3 Starting with the Network Module ...................................................................................................................................... 11
2.4 Mounting the Network Module ........................................................................................................................................... 11
2.5 Wiring the RS-485 Modbus RTU terminal ........................................................................................................................... 11
2.5.1 Modbus Common/GND (0V pin on terminal block) connection..................................................................................... 11
2.5.2 Cable shield connection (foiled or braided).................................................................................................................... 12
2.5.3 Two-wire networks........................................................................................................................................................ 12
2.5.4 Four-wire networks ....................................................................................................................................................... 12
2.5.5 Configuring the termination........................................................................................................................................... 13
2.6 Accessing the Network Module .......................................................................................................................................... 15
2.6.1 Accessing the web interface through Network............................................................................................................. 15
2.6.2 Finding and setting the IP address ................................................................................................................................ 15
2.6.3 Accessing the web interface through RNDIS................................................................................................................ 16
2.6.4 Accessing the card through serial terminal emulation................................................................................................... 19
2.6.5 Modifying the Proxy exception list ................................................................................................................................ 21
2.7 Configuring Modbus ............................................................................................................................................................ 23
2.7.1 Configuring the communication parameters ................................................................................................................. 23
2.7.2 Available maps............................................................................................................................................................... 23
2.7.3 Adding a Custom MAP .................................................................................................................................................. 24
2.7.4 Modbus communication monitoring tool....................................................................................................................... 24
2.7.5 Example of supported Modbus mapping ...................................................................................................................... 24
2.8 Configuring the Network Module settings .......................................................................................................................... 28
2.8.1 Menu structure.............................................................................................................................................................. 28

3 CONTEXTUAL HELP OF THE WEB INTERFACE ............................................................................................. 30


3.1 Login page ........................................................................................................................................................................... 30
3.1.1 Logging in for the first time ........................................................................................................................................... 30
3.1.2 Troubleshooting............................................................................................................................................................. 31
3.2 Home................................................................................................................................................................................... 32
3.2.1 Header structure............................................................................................................................................................ 32
3.2.2 Menu structure.............................................................................................................................................................. 33
3.2.3 Energy flow diagram...................................................................................................................................................... 34
3.2.4 Outlet status.................................................................................................................................................................. 38
3.2.5 Active Alarms ................................................................................................................................................................ 38
3.2.6 Environment .................................................................................................................................................................. 39
3.2.7 Energy flow diagram examples ..................................................................................................................................... 40
3.2.8 Access rights per profiles .............................................................................................................................................. 47
3.3 Meters ................................................................................................................................................................................. 48
3.3.1 Measures....................................................................................................................................................................... 48
3.3.2 Battery ........................................................................................................................................................................... 50
3.3.3 Data logs........................................................................................................................................................................ 52
3.3.4 Default settings and possible parameters - Meters ...................................................................................................... 52
3.3.5 Access rights per profiles .............................................................................................................................................. 53
3.3.6 Save and Restore .......................................................................................................................................................... 53
3.4 Controls ............................................................................................................................................................................... 54
3.4.1 Entire UPS ..................................................................................................................................................................... 54
3.4.2 Outlets - Group 1/ Group 2 ............................................................................................................................................ 55
3.4.3 Group............................................................................................................................................................................. 56
3.4.4 Schedule........................................................................................................................................................................ 58
3.5 Protection ............................................................................................................................................................................ 61
3.5.1 Agents list...................................................................................................................................................................... 61
3.5.2 Agent shutdown sequencing......................................................................................................................................... 65
3.5.3 Shutdown on power outage .......................................................................................................................................... 69
3.6 Environment ........................................................................................................................................................................ 77
3.6.1 Commissioning/Status................................................................................................................................................... 77
3.6.2 Alarm configuration ....................................................................................................................................................... 82
3.6.3 Information .................................................................................................................................................................... 85
3.7 Settings ............................................................................................................................................................................... 86
3.7.1 General .......................................................................................................................................................................... 86
3.7.2 Local users .................................................................................................................................................................... 98
3.7.3 Remote users .............................................................................................................................................................. 104
3.7.4 Protocols...................................................................................................................................................................... 119
3.7.5 SNMP .......................................................................................................................................................................... 123
3.7.6 Industrial protocols ...................................................................................................................................................... 133
3.7.7 Certificate .................................................................................................................................................................... 142
3.8 Device details .................................................................................................................................................................... 152
3.8.1 General ........................................................................................................................................................................ 152
3.8.2 Settings - UPS ............................................................................................................................................................. 153
3.8.3 Settings - ATS.............................................................................................................................................................. 154
3.8.4 Power Modules ........................................................................................................................................................... 155
3.9 Maintenance...................................................................................................................................................................... 155
3.9.1 Firmware ..................................................................................................................................................................... 155
3.9.2 Services ....................................................................................................................................................................... 160
3.9.3 Resources.................................................................................................................................................................... 166
3.9.4 System logs................................................................................................................................................................. 168
3.9.5 System information ..................................................................................................................................................... 169
3.10 Alarms ............................................................................................................................................................................... 170
3.10.1 Alarm sorting ............................................................................................................................................................... 170
3.10.2 Active alarm counter.................................................................................................................................................... 170
3.10.3 Alarm details................................................................................................................................................................ 170
3.10.4 Alarm paging................................................................................................................................................................ 171
3.10.5 Export .......................................................................................................................................................................... 171
3.10.6 Clear ............................................................................................................................................................................ 171
3.10.7 Alarms list with codes ................................................................................................................................................. 171
3.10.8 Access rights per profiles ............................................................................................................................................ 171
3.11 User profile ........................................................................................................................................................................ 172
3.11.1 Access to the user profile............................................................................................................................................ 172
3.11.2 User profile .................................................................................................................................................................. 172
3.11.3 Legal information......................................................................................................................................................... 175
3.11.4 Component.................................................................................................................................................................. 175
3.11.5 Availability of source code ........................................................................................................................................... 175
3.11.6 Notice for proprietary elements................................................................................................................................... 175
3.11.7 Default settings and possible parameters - User profile ............................................................................................. 176
3.11.8 Access rights per profiles ............................................................................................................................................ 176
3.11.9 CLI commands ............................................................................................................................................................ 177
3.11.10 Troubleshooting........................................................................................................................................................... 177
3.11.11 Save and Restore ........................................................................................................................................................ 178
3.12 Documentation .................................................................................................................................................................. 179
3.12.1 Access to the embedded documentation ................................................................................................................... 179
3.12.2 Access rights per profiles ............................................................................................................................................ 179

4 SERVICING THE NETWORK MANAGEMENT MODULE ............................................................................... 181


4.1 Configuring/Commissioning/Testing LDAP ....................................................................................................................... 181
4.1.1 Commissioning............................................................................................................................................................ 181
4.1.2 Testing LDAP connection ............................................................................................................................................ 182
4.1.3 Limitations ................................................................................................................................................................... 182
4.2 Pairing agent to the Network Module ............................................................................................................................... 182
4.2.1 Pairing with credentials on the agent .......................................................................................................................... 182
4.2.2 Pairing with automatic acceptance (recommended if done in a secure and trusted network).................................... 182
4.2.3 Pairing with manual acceptance .................................................................................................................................. 183
4.3 Powering down/up applications (examples) ...................................................................................................................... 183
4.3.1 Powering down IT system in a specific order ............................................................................................................. 183
4.3.2 Powering down non-priority equipment first ............................................................................................................... 186
4.3.3 Restart sequentially the IT equipment on utility recovery ........................................................................................... 189
4.4 Checking the current firmware version of the Network Module....................................................................................... 191
4.5 Accessing to the latest Network Module firmware/driver/script....................................................................................... 191
4.6 Upgrading the card firmware (Web interface / shell script) ............................................................................................... 191
4.6.1 Web interface .............................................................................................................................................................. 191
4.6.2 Shell script ................................................................................................................................................................... 191
4.6.3 Example:...................................................................................................................................................................... 192
4.7 Changing the RTC battery cell ........................................................................................................................................... 193
4.8 Updating the time of the Network Module precisely and permanently (ntp server) ......................................................... 194
4.9 Synchronizing the time of the Network Module and the UPS........................................................................................... 194
4.9.1 Automatic time synchronization .................................................................................................................................. 194
4.9.2 Manual time synchronization....................................................................................................................................... 194
4.10 Changing the language of the web pages ......................................................................................................................... 194
4.11 Resetting username and password................................................................................................................................... 195
4.11.1 As an admin for other users ........................................................................................................................................ 195
4.11.2 Resetting its own password........................................................................................................................................ 195
4.12 Recovering main administrator password ......................................................................................................................... 195
4.13 Switching to static IP (Manual) / Changing IP address of the Network Module................................................................ 196
4.14 Reading device information in a simple way ..................................................................................................................... 197
4.14.1 Web page .................................................................................................................................................................... 197
4.15 Subscribing to a set of alarms for email notification.......................................................................................................... 197
4.15.1 Example #1: subscribing only to one alarm (load unprotected) ................................................................................... 197
4.15.2 Example #2: subscribing to all Critical alarms and some specific Warnings ............................................................... 198
4.16 Saving/Restoring/Duplicating Network module configuration settings ............................................................................. 199
4.16.1 Modifying the JSON configuration settings file........................................................................................................... 199
4.16.2 Saving/Restoring/Duplicating settings through the CLI ............................................................................................... 204
4.16.3 Saving/Restoring/Duplicating settings through the Web interface.............................................................................. 204

5 SECURING THE NETWORK MANAGEMENT MODULE................................................................................ 205


5.1 Cybersecurity considerations for electrical distribution systems ...................................................................................... 205
5.1.1 Purpose ....................................................................................................................................................................... 205
5.1.2 Introduction ................................................................................................................................................................. 205
5.1.3 Connectivity—why do we need to address cybersecurity for industrial control systems (ICS)? ................................ 205
5.1.4 Cybersecurity threat vectors ....................................................................................................................................... 205
5.1.5 Defense in depth ......................................................................................................................................................... 206
5.1.6 Designing for the threat vectors.................................................................................................................................. 207
5.1.7 Policies, procedures, standards, and guidelines.......................................................................................................... 209
5.1.8 Conclusion ................................................................................................................................................................... 211
5.1.9 Terms and definitions .................................................................................................................................................. 211
5.1.10 Acronyms .................................................................................................................................................................... 211
5.1.11 References .................................................................................................................................................................. 212
5.2 Cybersecurity recommended secure hardening guidelines .............................................................................................. 213
5.2.1 Introduction ................................................................................................................................................................. 213
5.2.2 Secure configuration guidelines .................................................................................................................................. 213
5.2.3 References .................................................................................................................................................................. 219
5.3 Configuring user permissions through profiles.................................................................................................................. 220
5.4 Decommissioning the Network Management module ..................................................................................................... 220

6 SERVICING THE EMP .................................................................................................................................... 221


6.1 Description and features ................................................................................................................................................... 221
6.2 Unpacking the EMP........................................................................................................................................................... 221
6.3 Installing the EMP ............................................................................................................................................................. 222
6.3.1 Defining EMPs address and termination ..................................................................................................................... 222
6.3.2 Mounting the EMP ...................................................................................................................................................... 222
6.3.3 Cabling the first EMP to the device............................................................................................................................. 225
6.3.4 Daisy chaining EMPs ................................................................................................................................................... 225
6.3.5 Connecting an external contact device........................................................................................................................ 226
6.4 Commissioning the EMP................................................................................................................................................... 227
6.4.1 On the Network Module device .................................................................................................................................. 227
6.5 Using the EMP for temperature compensated battery charging....................................................................................... 227
6.5.1 Addressing the EMP.................................................................................................................................................... 228
6.5.2 Commissioning the EMP............................................................................................................................................. 228
6.5.3 Enabling temperature compensated battery charging in the UPS............................................................................... 228

7 INFORMATION............................................................................................................................................... 229
7.1 Front panel connectors and LED indicators....................................................................................................................... 229
7.2 Specifications/Technical characteristics ............................................................................................................................ 230
7.3 Default settings and possible parameters ......................................................................................................................... 231
7.3.1 Meters ......................................................................................................................................................................... 231
7.3.2 Settings ....................................................................................................................................................................... 231
7.3.3 Sensors alarm configuration ........................................................................................................................................ 238
7.3.4 User profile .................................................................................................................................................................. 238
7.4 Access rights per profiles .................................................................................................................................................. 240
7.4.1 Home........................................................................................................................................................................... 240
7.4.2 Meters ......................................................................................................................................................................... 240
7.4.3 Controls ....................................................................................................................................................................... 240
7.4.4 Protection .................................................................................................................................................................... 240
7.4.5 Environment ................................................................................................................................................................ 241
7.4.6 Settings ....................................................................................................................................................................... 241
7.4.7 Maintenance................................................................................................................................................................ 242
7.4.8 Alarms ......................................................................................................................................................................... 242
7.4.9 User profile .................................................................................................................................................................. 243
7.4.10 Contextual help............................................................................................................................................................ 243
7.4.11 CLI commands ............................................................................................................................................................ 243
7.5 List of event codes ............................................................................................................................................................ 245
7.5.1 System log codes ........................................................................................................................................................ 245
7.5.2 UPS(HID) alarm log codes ........................................................................................................................................... 250
7.5.3 UPS(XCP and COPI) alarm log codes .......................................................................................................................... 256
7.5.4 ATS alarm log codes.................................................................................................................................................... 263
7.5.5 EMP alarm log codes................................................................................................................................................... 265
7.5.6 Network module alarm log codes................................................................................................................................ 266
7.6 SNMP traps ....................................................................................................................................................................... 267
7.6.1 UPS Mib ...................................................................................................................................................................... 267
7.6.2 ATS Mib....................................................................................................................................................................... 270
7.6.3 Sensor Mib .................................................................................................................................................................. 271
7.7 CLI ..................................................................................................................................................................................... 271
7.7.1 Commands available.................................................................................................................................................... 271
7.7.2 Contextual help............................................................................................................................................................ 272
7.7.3 get release info............................................................................................................................................................ 272
7.7.4 history.......................................................................................................................................................................... 273
7.7.5 logout........................................................................................................................................................................... 273
7.7.6 maintenance ................................................................................................................................................................ 274
7.7.7 modbus_message_display .......................................................................................................................................... 275
7.7.8 modbus_statistics........................................................................................................................................................ 275
7.7.9 netconf ........................................................................................................................................................................ 276
7.7.10 ping and ping6 ............................................................................................................................................................. 278
7.7.11 reboot .......................................................................................................................................................................... 279
7.7.12 save_configuration | restore_configuration.................................................................................................................. 279
7.7.13 sanitize......................................................................................................................................................................... 280
7.7.14 ssh-keygen .................................................................................................................................................................. 280
7.7.15 time ............................................................................................................................................................................. 281
7.7.16 traceroute and traceroute6 .......................................................................................................................................... 282
7.7.17 whoami........................................................................................................................................................................ 283
7.7.18 email-test..................................................................................................................................................................... 283
7.7.19 systeminfo_statistics................................................................................................................................................... 284
7.7.20 certificates ................................................................................................................................................................... 284
7.8 Legal information............................................................................................................................................................... 285
7.8.1 Availability of Source Code .......................................................................................................................................... 285
7.8.2 Notice for Open Source Elements............................................................................................................................... 286
7.8.3 Notice for our proprietary (i.e. non-Open source) elements ........................................................................................ 286
7.9 Acronyms and abbreviations ............................................................................................................................................. 287

8 TROUBLESHOOTING..................................................................................................................................... 290
8.1 Action not allowed in Control/Schedule/Power outage policy ........................................................................................... 290
8.1.1 Symptom ..................................................................................................................................................................... 290
8.1.2 Possible Cause ............................................................................................................................................................ 290
8.1.3 Action .......................................................................................................................................................................... 290
8.2 Card wrong timestamp leads to "Full acquisition has failed" error message on Software................................................. 290
8.2.1 Symptoms: .................................................................................................................................................................. 290
8.2.2 Possible cause:............................................................................................................................................................ 290
8.2.3 Action: ......................................................................................................................................................................... 290
8.3 Client server is not restarting ............................................................................................................................................ 290
8.3.1 Symptom ..................................................................................................................................................................... 290
8.3.2 Possible Cause ............................................................................................................................................................ 290
8.3.3 Action .......................................................................................................................................................................... 291
8.4 EMP communication status shows "Lost"......................................................................................................................... 291
8.4.1 Symptom #1 ................................................................................................................................................................ 291
8.5 EMP detection fails at discovery stage ............................................................................................................................. 291
8.5.1 Symptom #1 ................................................................................................................................................................ 291
8.5.2 Symptom #2 ................................................................................................................................................................ 292
8.6 How do I log in if I forgot my password? .......................................................................................................................... 292
8.6.1 Action .......................................................................................................................................................................... 292
8.7 Software is not able to communicate with the Network module...................................................................................... 293
8.7.1 Symptoms ................................................................................................................................................................... 293
8.7.2 Possible cause............................................................................................................................................................. 293
8.7.3 Setup ........................................................................................................................................................................... 293
8.7.4 Action #1 ..................................................................................................................................................................... 293
8.7.5 Action #2 ..................................................................................................................................................................... 293
8.8 LDAP configuration/commissioning is not working........................................................................................................... 294
8.9 Modbus communication doesn't work.............................................................................................................................. 294
8.9.1 Symptoms ................................................................................................................................................................... 294
8.9.2 Possible cause............................................................................................................................................................. 294
8.10 Password change in My profile is not working.................................................................................................................. 295
8.10.1 Symptoms ................................................................................................................................................................... 295
8.10.2 Possible cause............................................................................................................................................................. 295
8.10.3 Action .......................................................................................................................................................................... 295
8.11 SNMPv3 password management issue with Save and Restore ....................................................................................... 295
8.11.1 Affected FW versions.................................................................................................................................................. 295
8.11.2 Symptom ..................................................................................................................................................................... 295
8.11.3 Cause........................................................................................................................................................................... 295
8.11.4 Action .......................................................................................................................................................................... 295
8.12 The alarm list has been cleared after an upgrade.............................................................................................................. 295
8.12.1 Symptom ..................................................................................................................................................................... 295
8.12.2 Action .......................................................................................................................................................................... 295
8.13 The Network Module fails to boot after upgrading the firmware ...................................................................................... 296
8.13.1 Possible Cause ............................................................................................................................................................ 296
8.13.2 Action .......................................................................................................................................................................... 296
8.14 Web user interface is not up to date after a FW upgrade ................................................................................................. 296
8.14.1 Symptom ..................................................................................................................................................................... 296
Applicable product: Eaton UPS-ATS

Table of Contents – 10
Overview

2 Installing the Network Management Module

2.1 Overview

2.2 Unpacking the Network module


The INDGW-M2
will include the following accessories:
• Installation instructions
• USB AM to Micro USB/M/5P 5ft Cable
• RS-485 wiring terminal

Packing materials must be disposed of in compliance with all local regulations concerning waste.
Recycling symbols are printed on the packing materials to facilitate sorting.

2.3 Starting with the Network Module

2.4 Mounting the Network Module


It is not necessary to power down the Device before installing the Network Module. Required tools: No. 2 Phillips
screwdriver.

The Network Module is hot-swappable. Inserting and/or extracting the Network Module from the communication slot of the product
has no effect on the output.
Remove the two screws securing the option slot cover plate and store the plate for possible future use.
• Install the Network Module along the alignment channels in the option slot.
• Secure the Network Module using the two screws.

2.5 Wiring the RS-485 Modbus RTU terminal


The Modbus Network Module provides an easy path for integrating an EatonUPS into an RS-485 Modbus network and also
provides isolation of the communication between the UPS and the RS-485 Modbus network.
Use the terminal strip on the Modbus Network Module to wire into a two-wire network.

If the Modbus Network Module is the last device installed in the network chain or the length of the network cable is
excessive, termination needs to be enabled.
For details on termination, see the Installing the Network Management Module>>>Wiring the RS-485 Modbus
RTU terminal>>>Configuring the termination section.

2.5.1 Modbus Common/GND (0V pin on terminal block) connection


The Network Module is an isolated device, if all the other devices on the network are isolated, common/GND (0V pin on terminal
block) should be connected between devices to limit common mode voltage.
Common/GND (0V pin on terminal block) should not be connected to any other devices that is not isolated to avoid ground loops.

Installing the Network Management Module – 11


Wiring the RS-485 Modbus RTU terminal

2.5.2 Cable shield connection (foiled or braided)


The cable shield should be continuous on the entire length of the bus and should be connected to ground (earth) at only one point
to limit the flow of ground-loop currents in the shield caused by ground potential differences.

2.5.3 Two-wire networks


• Interconnect R- with T- and R+ with T+ on the Modbus Network Module terminal strip.
• Connect the RS-485 network signal + to the R+ or T+ on the Modbus Network Module terminal strip.
• Connect the RS-485 network signal – to the R- or T- on the Modbus Network Module terminal strip.

Belden 3106A-22AWG or equivalent cabling (a 1.5 twisted-pair shielded 120Ω cable with ground) is recommended.

2.5.4 Four-wire networks


All four RS-485 network signals including T-, T+, R–, and R+ must be connected respectively to the terminal strip R-, R+, T-, T+.

Installing the Network Management Module – 12


Wiring the RS-485 Modbus RTU terminal

Belden 9843-24AWG or equivalent cabling (3 twisted-pair shielded 120Ω cable with ground) is recommended.

2.5.5 Configuring the termination


If the card is the last device installed in the network chain or the length of the network cable is excessive, termination needs to be
enabled.
Termination is used to match impedance of a node to the impedance of the transmission line being used. When impedances are
mismatched, the transmitted signal is not completely absorbed by the load and a portion is reflected into the transmission line.

No more than two termination points should be used in the RS-485 network.

To enable the on-board termination resistor (120Ω):

1. Locate the termination switch that is located on the top of the Modbus Network Module.

Installing the Network Management Module – 13


Wiring the RS-485 Modbus RTU terminal

2. Peel off the protection:

3. Change the position of the termination switch according to your needs:

Switch position

No termination (default)

Termination for two-wire networks One of the two position below can be used:

or

Installing the Network Management Module – 14


Accessing the Network Module

Termination for four-wire networks

2.6 Accessing the Network Module


2.6.1 Accessing the web interface through Network

2.6.1.1 Connecting the network cable


Security settings in the Network Module may be in their default states.
For maximum security, configure through a USB connection before connecting the network cable.

Connect a standard gigabit compatible shielded ethernet cable (F/UTP or F/FTP) between the network connector on the Network Module and a
network jack.

2.6.1.2 Accessing the web interface


It is highly recommended that browser access to the Network Module is isolated from outside access using a
firewall or isolated network.

STEP 1 – On a network computer, launch a supported web browser. The browser window appears.
STEP 2 – In the Address/Location field, enter https://[IP address] with the static IP address of the Network Module.
STEP 3 – The login screen appears.
STEP 4 – Enter the user name in the User Name field. The default user name is admin.
STEP 5 – Enter the password in the Password field. The default password is admin.
STEP 6 – The password must be changed at first login.
STEP 7 – Click Login. The Network Module web interface appears.
At first login:
STEP 8 - Accept License Agreement. The Network Module web interface appears.

2.6.2 Finding and setting the IP address

2.6.2.1 Your network is equipped with a BOOTP/DHCP server (default)

2.6.2.1.1 Read from the device LCD

Installing the Network Management Module – 15


Accessing the Network Module

Note: some older Devices may not be able to display the IP address even if they have an LCD. Please consult the
Device manual.

If your device has an LCD, from the LCD’s menu, navigate to Identification>>>"COM card IPv4".
• Note the IP address of the card.
• Go to the section: Accessing the web interface through Network.

2.6.2.1.2 With web browser through the configuration port


For example, if your device does not have an LCD, the IP address can be discovered by accessing the web interface through RNDIS
and browsing to Settings>Network.
To access the web interface through RNDIS, see the Accessing the web interface through RNDIS section.
• Navigate to Contextual help>>>Settings>>>Network & Protocol>>>IPV4.
• Read the IPv4 settings.

2.6.2.2 Your network is not equipped with a BOOTP/DHCP server

2.6.2.2.1 Define from the configuration port


The IP address can be defined by accessing the web interface through RNDIS.
To access web interface through RNDIS, see the Accessing the web interface through RNDIS section.
Define the IP settings:
• Navigate to Contextual help>>>Settings>>>Network & Protocol>>>IPV4.
• Select Manual (Static IP).
• Input the following information: Address, Subnet Mask, Default Gateway
• Save the changes.

2.6.3 Accessing the web interface through RNDIS


This connection is used to access and configure the Network Module network settings locally through a RNDIS (Ethernet over USB
interface).

2.6.3.1 Connecting the configuration cable


1. Connect a Micro-B to USB cable to a USB connector on the host computer.
2. Connect the cable to the Settings connector on the Network Module.

2.6.3.2 Web interface access through RNDIS

2.6.3.2.1 Configuring the RNDIS

a Automatic configuration

RNDIS driver is used to emulate a network connection from USB.


After the card is connected to the PC, Windows® OS will automatically search for the RNDIS driver.

Installing the Network Management Module – 16


Accessing the Network Module

On some computers, the OS can find the RNDIS driver then configuration is completed, and you can go to
Accessing the web interface.
On some others it may fail then proceed to manual configuration.

b Manual configuration
STEP 1 – In case Windows® OS fails to find driver automatically, go to the Windows control panel>Network and sharing
center>Local area connection

STEP 2 – Right click on the RNDIS local area connection and select Properties.

STEP 3 – Select Internet Protocol Version 4 (TCP/IPv4)” and press the Properties button

Installing the Network Management Module – 17


Accessing the Network Module

STEP 4 – Then enter the configuration as below and validate (IP = 169.254.0.150 and mask = 255.255.0.0), click OK, then click on
Close.

Installing the Network Management Module – 18


Accessing the Network Module

2.6.3.2.2 Accessing the web interface


STEP 1 – Be sure that the Device is powered on.
STEP 2 – On the host computer, download the rndis.7z file from the website www.eaton.com/downloads and extract it. For more
information, navigate to Servicing the Network Management Module>>>Accessing to the latest Network Module firmware/
driver section.
STEP 3 – Launch setProxy.bat to add 169.254.* in proxy’s exceptions list, if needed. For manual configuration, navigate to Installing
the Network Management Module>>>Accessing the Network Module>>>Modifying the Proxy exception list section in the full
documentation.
STEP 4 – Launch a supported browser, the browser window appears.
STEP 5 – In the Address/Location field, enter: https://169.254.0.1, the static IP address of the Network Module for RNDIS. The log
in screen appears.
STEP 6 – Enter the user name in the User Name field. The default user name is admin.
STEP 7 – Enter the password in the Password field. The default password is admin.
STEP 8 – Click Login. The Network Module local web interface appears.

2.6.4 Accessing the card through serial terminal emulation


This connection is used to access and configure the Network Module network settings locally through Serial (Serial over USB
interface).

Installing the Network Management Module – 19


Accessing the Network Module

2.6.4.1 Connecting the configuration cable

STEP 1 – Connect the Micro-B to USB cable to a USB connector on the host computer.
STEP 2 – Connect the cable to the Settings connector on the Network Module.

2.6.4.2 Manual configuration of the serial connection


Serial driver is used to emulate a serial connection from USB.
After the card is connected to the PC, manual configuration of the driver is needed for Windows® OS to discover
the serial connection.

STEP 1 – On the host computer, download the rndis.7z file from the website www.eaton.com/downloads and extract it.
STEP 2 – Plug the USB cable and go to Windows® Device Manager.
STEP 3 – Check the CDC Serial in the list, if it is with a yellow exclamation mark implying that driver has not been installed follow
the steps 4-5-6-7 otherwise configuration is OK.

STEP 4 – Right click on it and select Update Driver Software. When prompted to choose how to search for device driver software,
choose Browse my computer for driver software. Select Let me pick from a list of device drivers on my computer.
STEP 5 – Select the folder where you have previously downloaded the driver file Click on Next.
STEP 6 – A warning window will come up because the driver is not signed. Select Install this driver software anyway

Installing the Network Management Module – 20


Accessing the Network Module

STEP 7 – The installation is successful when the COM port number is displayed for the Gadget Serial device in the Windows®
Device Manager.

2.6.4.3 Accessing the card through Serial


It is intended mainly for automated configuration of the network and time settings of the network card. It can also be used for
troubleshooting and remote reboot/reset of the network interface in case the web user interface is not accessible.
CLI can be accessed through:
• SSH
• Serial terminal emulation.

Changing network parameters may cause the card to become unavailable remotely. If this happens it can only be
reconfigured locally through USB.

You can see this list of available commands by typing in the CLI: ?
You can see the help by typing in the CLI: help

For more details, refer to Information>>>CLI section

2.6.5 Modifying the Proxy exception list


To connect to the Network Module via a USB cable and your system uses a Proxy server to connect to the internet, the proxy
settings can reject the IP address 169.254.0.1.
The 169.254. * Sequence is used to set up communication with devices via a physical connection.
To activate this connection, exceptions will have to be made in the proxy settings.
• Open Internet Explorer
• Navigate to settings, Internet options;

Installing the Network Management Module – 21


Accessing the Network Module

• Select the Connections tab


• Press LAN Settings

• Press ADVANCED

• Add the address 169.254. *

Installing the Network Management Module – 22


Configuring Modbus

• Press OK.
• Close Internet Explorer and re-open it.
• Now you can access the address 169.254.0.1 with Internet Explorer and any other browser.

2.7 Configuring Modbus


This section is only for the Modbus Network Module

2.7.1 Configuring the communication parameters


• Access the web interface through Network or RNDIS
• Navigate to Contextual help>>>Settings>>>Modbus and set the communication parameters to the desired settings.

For Modbus RTU configuration refer to the section Contextual help>>>Settings>>>Modbus>>>Modbus


RTU.

For Modbus TCP configuration refer to the section Contextual help>>>Settings>>>Modbus>>>Modbus TCP.

2.7.2 Available maps


• Access the web interface through Network or RNDIS
• Navigate to Contextual help>>>Settings>>>Modbus and press the Supported MAPs button to download the MAPs.

File is generated in real time and will take into account the device capabilities and values at the time of the
generation.
Table in the downloaded file will show all possible registers, only the one showing Available equal to True will be
supported by your system.The units used on Modbus map belong to the International System of Units,
temperatures are expressed in Kelvin for example.

Installing the Network Management Module – 23


Configuring Modbus

2.7.2.1 Mapping table content


• address (hex): register address in hexadecimal
• address (1-base): register address in 1-base format
• Type: Register/Discrete
• Size in bytes
• Number of modbus registers
• Writable: True/False
• Representation: Int16/Uint16/String/Boolean/...
• Name
• Description
• Unit (Kelvin, A, V, W, VA, %, Hz, min, ...)
• Status to 0: status when the discrete equal 0
• Status to 1: status when the discrete equal 1
• Available: True/False – Shows if the register is available on current device
• Value: Shows current value of the register on current device

For an example of supported Modbus mapping, navigate to Installing the Network Management
Module>>>Configuring Modbus>>>Example of supported Modbus mapping.

2.7.3 Adding a Custom MAP


On top of the available MAPs, navigating through the Settings > Industrial Protocols > Modbus Mapping Configuration you can add
a new MAP by clicking the "new" button.

2.7.4 Modbus communication monitoring tool


• Access the CLI through SSH or the Serial terminal emulation
• Get available commands by typing ? in the CLI
CLI commands can be used to retrieve Modbus communication statistics,
see Information>>>CLI>>>modbus_statistics section for more details.

2.7.5 Example of supported Modbus mapping


The following table is an example of the mapping information that can be retrieved in the Modbus settings by pressing the
Supported MAPs button.

Installing the Network Management Module – 24


Configuring Modbus

Installing the Network Management Module – 25


Configuring Modbus

Installing the Network Management Module – 26


Configuring Modbus

Installing the Network Management Module – 27


Configuring the Network Module settings

2.8 Configuring the Network Module settings


Use the web interface to configure the Network Module. The main web interface menus are described below:

2.8.1 Menu structure

Extend menu display.

Installing the Network Management Module – 28


Configuring the Network Module settings

Home: Overview and status of the Device (Active alarms, Outlet status, ...).

Meters: Power quality meters and logs.

Controls: Device and outlets control.

Protection: Agents list, Agents shutdown sequencing, Shutdown on power outage.

Environment: Commissioning/Status, Alarm configuration, Information.

Settings: Network Module settings.

Device settings: General information, Settings.

or

Maintenance: Firmware, Services, Resources, System logs.

FW Display Network module firmware version.

Time Display Network Module local time (not the UTC time).

Installing the Network Management Module – 29


Login page

3 Contextual help of the web interface

3.1 Login page

The page language is set to English


by default but can be switched to browser language when it is managed.
After navigating to the assigned IP address, accept the untrusted certificate on the browser.

3.1.1 Logging in for the first time

3.1.1.1 1. Enter default password


As you are logging into the Network Module for the first time you must enter the factory set default username and password.
• Username = admin
• Password = admin

3.1.1.2 2. Change default password


Changing the default password is mandatory and requested in a dedicated window.
Enter your current password first, and then enter the new password twice.
Follow the password format recommendations on the tooltip in order to define a secure password.

Contextual help of the web interface – 30


Login page

3.1.1.3 3. Accept license agreement


On the next step, License Agreement is displayed.
Read and accept the agreement to continue.

Accounts with identical names


When an user attempt to log with a user name that exist both locally & remotely, then only the local account can
successfully be logged in by default.

Two options for the remote user to successfully log in


1. You can use a prefix to access the remote account. For example ldap\johndoe or radius\johndoe depending
on the remote configuration you set in the card.
2. Change the user name of the local account

3.1.2 Troubleshooting
How do I log in if I forgot my password?

Action
• Ask your administrator for password initialization.
• If you are the main administrator, your password can be reset manually by following steps described in the Servicing
the Network Management Module>>>Recovering main administrator password .

Web user interface is not up to date after a FW upgrade

Symptom
After an upgrade:
• The Web interface is not up to date
• New features of the new FW are not displayed
• An infinite spinner is displayed on a tile

Possible causes
The browser is displaying the Web interface through the cache that contains previous FW data.

Action
Empty the cache of your browser using F5 or CTRL+F5.

Contextual help of the web interface – 31


Home

3.1.2.1 For other issues


For details on other issues, see the Troubleshooting section.

3.2 Home
The Home screen provides status information for the device including key measures and active alarms.

3.2.1 Header structure

Name Displays the Network module name.

Device name Displays by default the Device model or the system name if filled in the section Contextual
help>>>Maintenance>>>System information .

Shortcut to the Device details:

• Name
• Location
• Model

Contextual help of the web interface – 32


Home

• P/N
• S/N
• FW version

Device status Displays if the Device is Online, On bypass, On battery...

Displays the battery level (in %) and the remaining backup time.

Output load level

Help: Opens full documentation in a separate browser page.

Profile: Displays user profile, password change, account information, logout and legal information.

Alarms: Open alarm page and displays the number of active alarms.

3.2.2 Menu structure

Extend menu display.

Home: Overview and status of the Device (Active alarms, Outlet status, ...).

Meters: Power quality meters and logs.

Controls: Device and outlets control.

Protection: Agents list, Agents shutdown sequencing, Shutdown on power outage.

Contextual help of the web interface – 33


Home

Environment: Commissioning/Status, Alarm configuration, Information.

Settings: Network Module settings.

Device settings: General information, Settings.

or

Maintenance: Firmware, Services, Resources, System logs.

FW Display Network module firmware version.

Time Display Network Module local time (not the UTC time).

3.2.3 Energy flow diagram

Contextual help of the web interface – 34


Home

3.2.3.1 Line interactive UPS

3.2.3.2 Online UPS

3.2.3.3 ATS

3.2.3.4 Diagram elements description


Description and Description Possible states below the symbol
symbols
Good Warning Fault

Input Main utility input. In range Out of nominal range

Contextual help of the web interface – 35


Home

Output Output of the UPS. Protected In overload In short circuit


Powered Not protected

AVR device The equipment is protected and Normal mode In overload


powered through an AVR device.
Buck mode
Boost mode

Rectifier Rectifier: convert AC power to Normal In overload In short circuit


DC power.
HE mode (ready) / ESS In fault
mode (ready)

Battery/Charger Battery and internal battery Battery: Battery: Battery:


charger.
OK End of life In fault
Charger: Charger:
Charging In fault
Floating Not present
Resting
Off

Inverter Inverter: convert DC power to Normal In overload In short circuit


AC power.
In fault

Internal bypass Automatic bypass. Powered (standby, auto In overload In fault


bypass, forced bypass,
HE mode, ESS mode)

Maintenance bypass Maintenance bypass closed. Maintenance


(optional)

ATS device The equipment is powered


through an ATS device.

Contextual help of the web interface – 36


Home

Description and Description Possible states


symbols
Green Orange Black

Wiring Electrical connection between Energy flow In overload No energy


blocks.
Out of nominal range Unknown

3.2.3.5 Details

To access the device details, press the icon:


This view provides a summary of device identification information and nominal values:
• Name
• Model
• P/N
• S/N
• Location
• Firmware version
• Input Voltage
• Input Frequency
• Output Voltage
• Output Frequency
The COPY TO CLIPBOARD button will copy the information to your clipboard.
For example, you can copy and paste information into an email.

3.2.3.6 Show measures


Provides input and output measures on the synoptic.

3.2.3.6.1 Example #1
Single input source with 1 phase in and 1 phase out:

Input measures Output measures

Voltage (V) Voltage (V)


Current (A) Current (A)
Frequency (Hz) Frequency (Hz)

3.2.3.6.2 Example #2
Dual input sources with 3 phases in and 3 phases out

Input measures (main and secondary) Output measures

Phase #1 Phase #2 Phase #3 Phase #1 Phase #2 Phase #3


Voltage (V) Voltage (V) Voltage (V) Voltage (V) Voltage (V) Voltage (V)
Current (A) Current (A) Current (A) Current (A) Current (A) Current (A)
Load (W)
Load (%)

Contextual help of the web interface – 37


Home

Input measures (main and secondary) Output measures

Frequency (Hz) Frequency (Hz)

3.2.4 Outlet status

Provides the status of the UPS outlets (ON/OFF) by load segmentation:


• Status (ON/OFF— Protected/Not protected/Not powered)
• Load level (W) – availability depending on the UPS model

Note: Load segmentations allow non-priority equipment to automatically power down during an extended power
outage to keep battery runtime on essential equipment.
This feature is also used to remote reboot and sequential start servers to restrict inrush currents.

Note: To access Controls menu, press the icon:

3.2.5 Active Alarms

Only active alarms are displayed, the Alarms icon will also display the number of active alarms.
Alarms are sorted by date, alert level, time, and description.

Note: To see the alarm history, press the icon:

Contextual help of the web interface – 38


Home

3.2.6 Environment

UPS ambient temperature is displayed if available.


Sensor status and data are displayed if available, MIN-MAX shows the minimal and maximal temperature or humidity measured by
the sensor.

Note: To see detailed sensor data, press the icon:

Contextual help of the web interface – 39


Home

3.2.7 Energy flow diagram examples

3.2.7.1 Line interactive UPS

3.2.7.1.1 Normal mode

3.2.7.1.2 Buck/Boost mode

Contextual help of the web interface – 40


Home

3.2.7.1.3 Battery mode

3.2.7.1.4 Off mode

Contextual help of the web interface – 41


Home

3.2.7.2 Online UPS with single input source

3.2.7.2.1 Online mode

3.2.7.2.2 Bypass mode

Contextual help of the web interface – 42


Home

3.2.7.2.3 Battery mode

3.2.7.2.4 Off mode

Contextual help of the web interface – 43


Home

3.2.7.2.5 HE mode / ESS mode

3.2.7.3 Online UPS with dual inputs sources and Maintenance bypass

3.2.7.3.1 Online mode

Contextual help of the web interface – 44


Home

3.2.7.3.2 Bypass mode

3.2.7.3.3 Battery mode

Contextual help of the web interface – 45


Home

3.2.7.3.4 HE mode / ESS mode

3.2.7.3.5 Maintenance bypass mode

Contextual help of the web interface – 46


Home

3.2.7.4 ATS

3.2.7.4.1 Normal mode

3.2.7.4.2 Prefered source missing

3.2.8 Access rights per profiles


Administrator Operator Viewer

Home

3.2.8.1 For other access rights


For other access rights, see the Information>>>Access rights per profiles section.

Contextual help of the web interface – 47


Meters

3.3 Meters
3.3.1 Measures
Gauge color code:
• Green: Value inside thresholds.
• Orange/Red: Value outside thresholds.
• Blue: No thresholds provided by the device.

3.3.1.1 Main utility input

Displays the product main utility measures.


• Current (A)
• Voltage (V)

Contextual help of the web interface – 48


Meters

3.3.1.2 Second utility input (if available)

If presents, displays the product second utility measures.


• Current (A)
• Voltage (V)

3.3.1.3 Output

• Voltage (V)
• Power (W)
• Current (A)

Contextual help of the web interface – 49


Meters

3.3.2 Battery

3.3.2.1 Battery status

Battery status section is an overview of the battery information.

The information displayed depends on the device.

3.3.2.1.1 Overview/Environment
• Type
• EBM count
• Nominal capacity
• Nominal voltage
• Capacity remaining
• Runtime
• State
• Recommended replacement date
• State of health
• Voltage
• Current
• Temperature
• Min cell voltage
• Max cell voltage
• Number of cycles
• Min temperature
• Max temperature
• BMS state
• Low battery warning threshold(s)
• UPS Restart threshold

3.3.2.1.2 Configurable parameters


• Battery replacement notification
• Enable / Disable
• Low battery warning threshold(s)
• % of battery remaining to enter low battery mode
• seconds of battery remaining to enter low battery mode
• UPS Restart threshold
• % of battery needed to restart safely the UPS

Contextual help of the web interface – 50


Meters

3.3.2.2 Battery health

Battery health section provides status of the battery and allow to launch a battery test.
The status reflects the last completed battery test result, as well as its critical status (color) and completion time.
• Pass
• Warning
• Fail
• Unknown

3.3.2.2.1 Commands
Launch test button is disabled if a battery test is already in progress or scheduled.
The Abort test button is enabled only when a test is in progress or scheduled.

3.3.2.2.2 Pending action


The pending action reflects the battery test status.
• None
• Scheduled
• In progress
• Aborted
• Done

Contextual help of the web interface – 51


Meters

3.3.3 Data logs

3.3.3.1 Logs

This log configuration allows to define the log acquisition frequency of the Device measures only.

The sensors measures logs acquisition is not settable and done every minutes. Sensors measures logs are
accessible in Environment menu.

3.3.3.1.1 Download

Press the icon on the top right to download the Device log file.
If available, possible measures are listed below:
• Input Voltage (V)
• Input Frequency (Hz)
• Bypass Voltage (V)
• Bypass Frequency (Hz)
• Output Voltage (V)
• Output Frequency (Hz)
• Output Current (A)
• Output Apparent Power (VA)
• Output Active Power (W)
• Output Power Factor
• Output Percent Load (%)
• Battery Voltage (V)
• Battery Capacity (%)
• Battery Remaining Time (s)

3.3.4 Default settings and possible parameters - Meters


Default setting Possible parameters

Meters/Logs Log measures every — 60s Log measures every — 3600s maximum

Contextual help of the web interface – 52


Meters

3.3.4.1 For other settings


For other settings, see the Information>>>Default settings parameters section.

3.3.5 Access rights per profiles


Administrator Operator Viewer

Meters

Battery health: Launch test/Abort

Logs configuration

3.3.5.1 For other access rights


For other access rights, see the Information>>>Access rights per profiles section.

3.3.6 Save and Restore


SRR section Settings Possible values

Logs measure periodicity [time in seconds]

3.3.6.1 Additional information


For details on Save and Restore, see the Save and Restore section.

Contextual help of the web interface – 53


Controls

3.4 Controls
3.4.1 Entire UPS

Controls are displayed for the entire UPS, and not for specific outlet options.
The table in this section displays UPS status, the associated commands (on/off), and the pending action.

3.4.1.1 Status
Reflects the current mode of the UPS. The following is a list of potential table values that are displayed based on the UPS topology.
• On — Protected/Not protected
• Off — Not powered/Not protected

3.4.1.2 Commands
A set of commands are available and activated when one of the following buttons is pressed. A confirmation window appears.
• Safe OFF
This will shut off the load. Protected applications will be safely powered down.
This control is available only if the status is not OFF and if there are no active commands running.
• Safe reboot
This will shut off and then switch ON the load. Protected applications will be safely powered down.
This control is available only if the status is not OFF and if there are no active commands running.
• Switch ON
This will switch ON the load or turn ON the online UPS.
This control is available when the status is OFF, if there are no active commands running and if the Online UPS is on bypass.

3.4.1.3 Pending action


Displays the delay before shutdown and delays before startup.

Contextual help of the web interface – 54


Controls

3.4.2 Outlets - Group 1/ Group 2

Load segmentations allow, battery runtime to remain on essential equipment and automatically power down non-priority equipment
during an extended power outage.
This feature is also used for remote reboot and the sequential start of servers to restrict inrush currents.

3.4.2.1 Status
It reflects the current outlet status.
• On — Protected/Not protected
• Off — Not powered

3.4.2.2 Commands
A set of commands are available and activated when one of the following buttons is pressed. A confirmation window appears.
• Safe OFF
This will shut off the load connected to the associated load segment. Protected applications are safely powered down.
This control is available only if the status is not OFF and if there are no active commands running.
• Safe reboot
This will power down and then switch ON the load connected to the associated load segment. Protected applications are
safely powered down.
This control is available only if the status is not OFF and if there are no active commands running.
• Switch ON
This will switch ON the load connected to the associated load segment.
This control is available when status is OFF and if there are no active commands running.

3.4.2.3 Pending action


Displays the delay before shutdown and delay before startup.

Contextual help of the web interface – 55


Controls

3.4.3 Group

3.4.3.1 Entire UPS

Controls are displayed for the entire UPS, and not for specific outlet options.
The table in this section displays UPS status, the associated commands (on/off), and the pending action.

3.4.3.1.1 Status
Reflects the current mode of the UPS. The following is a list of potential table values that are displayed based on the UPS topology.
• On — Protected/Not protected
• Off — Not powered/Not protected

3.4.3.1.2 Commands
A set of commands are available and activated when one of the following buttons is pressed. A confirmation window appears.
• Safe OFF
This will shut off the load. Protected applications will be safely powered down.
This control is available only if the status is not OFF and if there are no active commands running.
• Safe reboot
This will shut off and then switch ON the load. Protected applications will be safely powered down.
This control is available only if the status is not OFF and if there are no active commands running.
• Switch ON
This will switch ON the load or turn ON the online UPS.
This control is available when the status is OFF, if there are no active commands running and if the Online UPS is on bypass.

3.4.3.1.3 Pending action


Displays the delay before shutdown and delays before startup.

Contextual help of the web interface – 56


Controls

3.4.3.2 Outlets - Group 1/ Group 2

Load segmentations allow, battery runtime to remain on essential equipment and automatically power down non-priority equipment
during an extended power outage.
This feature is also used for remote reboot and the sequential start of servers to restrict inrush currents.

3.4.3.2.1 Status
It reflects the current outlet status.
• On — Protected/Not protected
• Off — Not powered

3.4.3.2.2 Commands
A set of commands are available and activated when one of the following buttons is pressed. A confirmation window appears.
• Safe OFF
This will shut off the load connected to the associated load segment. Protected applications are safely powered down.
This control is available only if the status is not OFF and if there are no active commands running.
• Safe reboot
This will power down and then switch ON the load connected to the associated load segment. Protected applications are
safely powered down.
This control is available only if the status is not OFF and if there are no active commands running.
• Switch ON
This will switch ON the load connected to the associated load segment.
This control is available when status is OFF and if there are no active commands running.

3.4.3.2.3 Pending action


Displays the delay before shutdown and delay before startup.

3.4.3.3 Access rights per profiles


Administrator Operator Viewer

Control

Contextual help of the web interface – 57


Controls

3.4.3.3.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.4.3.4 Troubleshooting

Action not allowed in Control/Schedule/Power outage policy

Symptom
Below message is displayed when you access the Control, Schedule or Power outage policy page.

This action is not allowed by the UPS.


To enable it, please refer to the user manual of the UPS and its instructions on how to configure the UPS settings and allow
remote commands.

Possible Cause
1- Remote commands are not allowed due to the UPS configuration (see the action below)
2- The UPS does not support remote commands.

Action
Refer to the UPS user manual and its instruction on how to configure the UPS settings and allow remote commands.
Example: UPS menu Settings>>>ON/OFF settings>>>Remote command>>>Enable.

3.4.3.4.1 For other issues

For details on other issues, see the Troubleshooting section.

3.4.4 Schedule
Use Scheduled shutdowns to turn off either the UPS or individual load segments at a specific day and time.
This feature is used for saving energy by turning off equipment outside of office hours or to enhance cybersecurity by powering
down network equipment.
If server shutdown scenarios are defined for any of the connected servers or appliances, they will be triggered before the
corresponding outlets are turned off as configured in shutdown settings.

Contextual help of the web interface – 58


Controls

3.4.4.1 Scheduled shutdown table

The table displays the scheduled shutdowns and includes the following details:
• Recurrence – Once/Every day/Every week
• Load segment – Primary/Group 1/Group 2
• Shutdown time – Date/Time
• Restart time – Date/Time
• Status – Active/Inactive

3.4.4.2 Actions

3.4.4.2.1 New
Press the New button to create a scheduled shutdown.

3.4.4.2.2 Delete
Select a schedule shutdown and press the Delete button to delete the scheduled shutdown.

3.4.4.2.3 Edit
Press the pen icon to edit schedule shutdown and to access the settings:

3.4.4.3 Access rights per profiles


Administrator Operator Viewer

Protection/Scheduled
shutdowns

3.4.4.3.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

Contextual help of the web interface – 59


Controls

3.4.4.4 Save and Restore


SRR section Settings Possible values

Scheduled shutdown schedule enabled true/false

scheduler 1: Primary
2: Group 1
3: Group 2

recurrence 0: once
1: every day
2: every week

shutdownTimeStamp [timestamp (unix)]

restartTimeStamp [timestamp (unix)]

3.4.4.4.1 Additional information

For details on Save and Restore, see the Save and Restore section.

3.4.4.5 Troubleshooting

Action not allowed in Control/Schedule/Power outage policy

Symptom
Below message is displayed when you access the Control, Schedule or Power outage policy page.

This action is not allowed by the UPS.


To enable it, please refer to the user manual of the UPS and its instructions on how to configure the UPS settings and allow
remote commands.

Possible Cause
1- Remote commands are not allowed due to the UPS configuration (see the action below)
2- The UPS does not support remote commands.

Action
Refer to the UPS user manual and its instruction on how to configure the UPS settings and allow remote commands.
Example: UPS menu Settings>>>ON/OFF settings>>>Remote command>>>Enable.

Contextual help of the web interface – 60


Protection

3.4.4.5.1 For other issues

For details on other issues, see the Troubleshooting section.

3.5 Protection
3.5.1 Agents list

3.5.1.1 Pairing with shutdown agents


For details on pairing instructions, follow the link pairing instructions in the tile or see the Servicing the Network
Management Module>>>Pairing agent to the Network Module section.

Authentication and encryption of connections between the UPS network module and shutdown agents is based on matching
certificates. Automated pairing of shutdown agents and UPS network modules is recommended in case the installation is done
manually in a secure and trusted network, and when certificates cannot be created in other ways.
During the selected timeframe, new agent connections to the Network Module are automatically trusted and accepted.
After automatic acceptance, make sure that all listed agents belong to your infrastructure. If not, access may be revoked using the
Delete button.
For maximum security, Eaton recommend following one of the two methods on the certificate settings page:
• Import client certificates manually.
• Generate trusted certificate for both clients and Network Module using your own PKI.

3.5.1.1.1 Actions

a Start
Starts the pairing window for the selected timeframe or until it is stopped.
Time countdown is displayed.

Contextual help of the web interface – 61


Protection

b Stop
Stops the pairing window.

3.5.1.2 Agents list table

The table displays the IPP agent list that is connected to the Network Module and includes the following details:
• Name
• Address
• Version of the Agent
• Power source (Powering strategy)
• Delay (in seconds)
• OS shutdown duration (in seconds)
• Status
• In service | Protected
• In service | Not protected
• Stopping | Protected
• Stopped | Protected
• Communication
• Connected | yyyy/mm/dd hh:mm:ss
• Lost | yyyy/mm/dd hh:mm:ss

3.5.1.3 Actions

3.5.1.3.1 Delete

When the agent is connected, the Delete function will not work correctly because the agent will keep on trying to
re-connect.
So connect to the software, remove the Network module from the Software nodes list (in the nodes list, right click
on the Network module and click remove nodes).

When communication with the agent is lost, agent can be deleted by using the Delete button.
Select an agent and press the Delete button to delete the agent.

3.5.1.4 Access rights per profiles


Administrator Operator Viewer

Protection/Agent list

3.5.1.4.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

Contextual help of the web interface – 62


Protection

3.5.1.5 Troubleshooting

Card wrong timestamp leads to "Full acquisition has failed" error message on Software

Symptoms:
IPP/IPM shows the error message "The full data acquisition has failed" even if the credentials are correct.

Possible cause:
The Network module timestamp is not correct.
Probably the MQTT certificate is not valid at Network module date.

Action:
Set the right date, time and timezone. If possible, use a NTP server, refer to Contextual
help>>>Settings>>>General>>>System details>>>Time & date settings section.

Software is not able to communicate with the Network module

Symptoms
• In the Network Module, in Contextual help>>>Protection>>>Agent list>>>Agent list table , agent is showing "Lost" as
a status.
• In the Network Module, in Contextual help>>>Settings>>>Certificate>>>Trusted remote certificates , the status of
the Protected applications (MQTT) is showing "Not valid yet".
• IPP/IPM shows "The authentication has failed", "The notifications reception encountered error".

Possible cause
The IPP/IPM certificate is not yet valid for the Network Module.
Certificates of IPP/IPM and the Network Module are not matching so that authentication and encryption of connections
between the Network Module and the shutdown agents is not working.

Setup
IPP/IPM is started.
Network module is connected to the UPS and to the network.

Action #1
Check if the IPP/IPM certificate validity for the Network Module.
STEP 1: Connect to the Network Module
• On a network computer, launch a supported web browser. The browser window appears.
• In the Address/Location field, enter: https://xxx.xxx.xxx.xxx/ where xxx.xxx.xxx.xxx is the static IP address of the
Network Module.
• The log in screen appears.
• Enter the user name in the User Name field.
• Enter the password in the Password field.
• Click Login. The Network Module web interface appears.
STEP 2: Navigate to Settings/Certificates page

Contextual help of the web interface – 63


Protection

STEP 3: In the Trusted remote certificates section, check the status of the Protected applications (MQTT).
If it is "Valid" go to Action#2 STEP 2, if it is "Not yet valid", time of the need to be synchronized with IPP/IPM .
STEP 4: Synchronize the time of the Network Module with IPP/IPM and check that the status of the Protected applications
(MQTT) is now valid.
Communication will then recover, if not go to Action#2 STEP 2.

Action #2
Pair agent to the Network Module with automatic acceptance (recommended in case the installation is done in a secure and
trusted network).

For manual pairing (maximum security), go to Servicing the Network Management Module>>>Pairing agent
to the Network Module section and then go to STEP 2, item 1.

STEP 1: Connect to the Network Module.


• On a network computer, launch a supported web browser. The browser window appears.
• In the Address/Location field, enter: https://xxx.xxx.xxx.xxx/ where xxx.xxx.xxx.xxx is the static IP address of the
Network Module.
• The log in screen appears.
• Enter the user name in the User Name field.
• Enter the password in the Password field.
• Click Login. The Network Module web interface appears.
STEP 2: Navigate to Protection/Agents list page.
STEP 3: In the Pairing with shutdown agents section, select the time to accept new agents and press the Start button
and Continue. During the selected timeframe, new agent connections to the Network Module are automatically trusted and
accepted.
STEP 4: Action on the agent ( IPP/IPM ) while the time to accepts new agents is running on the Network Module
Remove the Network module certificate file(s) *.0 that is (are) located in the folder
Eaton\IntelligentPowerProtector\configs\tls.

Client server is not restarting

Symptom
Utility power has been restored, the UPS and its load segments are powered on, but the Client server does not restart.

Possible Cause
The “Automatic Power ON” server setup setting might be disabled.

Action
In the server system BIOS, change the setting for Automatic Power ON to "Enabled".

3.5.1.5.1 For other issues

For details on other issues, see the Troubleshooting section.

Contextual help of the web interface – 64


Protection

3.5.2 Agent shutdown sequencing

3.5.2.1 Agent shutdown sequence timing

Contextual help of the web interface – 65


Protection

All agents that are connected to the Network Module are displayed in tables by power sources.
• Primary
• Group 1
• Group 2
The 'local agent' setting is used for setting for example a minimum shutdown duration, or a power down delay for a load segment
that has no registered shutdown agents.
One use case would be a load segment that powers network equipment that needs to stay on while servers and storage perform
their orderly shutdown.

A shutdown time summary is calculated and displayed on the top of the table:
• Shutdown time: maximum time (Delay + OS shutdown duration + 10s) calculated among all the agents.
• Immediate shutdown time (OS shutdown duration + 10s) calculated among all the agents.

The tables include the following details:


• Name
• Delay (in seconds)
• OS shutdown duration (in seconds)

3.5.2.2 Actions

3.5.2.2.1 Set Delay


Select and directly change the setting in the table and then Save.

3.5.2.2.2 Set OS shutdown duration


Select and directly change the setting in the table and then Save.

3.5.2.3 Examples
Examples below show the impact of agent settings on the shutdown sequence for a shutdown or an immediate shutdown.

Contextual help of the web interface – 66


Protection

3.5.2.3.1 Example #1

→ Shutdown time: 210s + 10s = 220s

→ Immediate shutdown time: 120s + 10s = 130s

Contextual help of the web interface – 67


Protection

3.5.2.3.2 Example #2

→ Shutdown time: 180s + 10s = 190s

→ Immediate shutdown time: 180s +10s = 190s

The trigger in the diagram is the moment when the shutdown sequence starts, and it is defined in the Contextual
help>>>Protection>>>Scheduled shutdown or the Contextual help>>>Protection>>>Shutdown on power
outage sections for each power source.

Contextual help of the web interface – 68


Protection

3.5.2.4 Access rights per profiles


Administrator Operator Viewer

Protection/Agent settings

3.5.2.4.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.5.3 Shutdown on power outage


These setting are in conjunction with the shutdown agents and control how the network module directs the shutdown of protected
servers and appliances. It gives the possibility to prioritize and schedule shutdown actions so that the IT system is powered down
in the correct order. For example, applications first, database servers next, and storage last. It is also possible to turn off some
outlets to reduce power consumption and get longer battery runtime for the most important devices.

For examples on Powering down applications see the Servicing the Network Management Module>>>Powering
down/up applications examples section.

3.5.3.1 Shutdown on power outage criteria

Contextual help of the web interface – 69


Protection

Shutdown criteria are set per power source (outlet groups) if they are present in the UPS.

By default, shutdown criterias are set to Maximize availability.

3.5.3.1.1 Shutdown criteria selection


The available criteria for shutdown are listed below:

a Maximize availability (default)


To end the shutdown sequence 30s before the end of backup time.

b Immediate OFF
To initiate the shutdown sequence when on battery for 10 seconds.

Load Shedding
To initiate the shutdown sequentially group by group.
This deliberate step by step shutdown will prevent a failure of the entire system. This reduces the load on the UPS system and
increases the runtime for the remaining loads.

Contextual help of the web interface – 70


Protection

Example

c Custom
Several conditions can be set to define shutdown criteria:
• To initiate the shutdown sequence when on battery for 10 seconds.
• To initiate the sequence when the battery reaches the set capacity in (%)
• To initiate or end the shutdown sequence after the set time in (s) before the end of backup time.
When there are several conditions to start the shutdown sequence, the shutdown sequence will start as soon as one of the
condition is reached.

When primary shuts OFF, both group1 and group 2 shut OFF immediately.
So if Primary is set to Immediate OFF, groups policies should be restricted to Immediate OFF.

d Settings examples
All the following examples are using below agent's settings.

→ Shutdown time: 210s

Example 1: Maximize availability

Contextual help of the web interface – 71


Protection

Example 2: Immediate OFF

Contextual help of the web interface – 72


Protection

Example 4: Custom

Settings #1

Contextual help of the web interface – 73


Protection

Settings #2

3.5.3.1.2 On low battery warning

In some cases, like a renewed power failure or failed battery, the capacity is much lower than anticipated. The UPS gives a Low
battery warning when there is 2 - 3 minutes of estimated runtime left, depending on the UPS and its settings. This time is typically
enough for shutting down a server but does not allow sophisticated sequential shutdown schemes.
The Low battery policy is intended for these cases.

Contextual help of the web interface – 74


Protection

3.5.3.1.3 When utility comes back

Note: When utility comes back settings cannot be altered for three phase UPS units and will remain at their defaults.
These settings define the restart sequence when utility comes back. For example, this allows sequential startup of the IT system
so that network and storage devices are connected to 'Primary' and start up immediately. After a delay database servers in Group1
are powered up, and then application and web servers in Group 2 are powered up. This startup would ensure that necessary
services would be available for each layer when needed. A sequential startup will also help avoid a peak power draw in the
beginning.

a Options
Keep shutdown sequence running until the end, and then restart (forced reboot).
Wait until UPS battery capacity exceeds a set percentage value in (%), and then automatically restart the UPS.
• Then restart Group 1 after a set time in (s).
• Then restart Group 2 after a set time in (s).

b Enable/Disable
Each option listed above can be enabled or disabled with check-boxes.
When disabled, the option will be greyed out.

3.5.3.2 Access rights per profiles


Administrator Operator Viewer

Protection/Sequence

3.5.3.2.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.5.3.3 Save and Restore


SRR section SRR sub section Settings Possible values

Shutdown on power outage powerOutagePolicy/Settings panicShutdownTrigger onLowStateOfCharge true/false


s

Contextual help of the web interface – 75


Protection

restart enabled true/false

powerOutagePolicy/ id 1: Primary
suppliersSettings
2: Group 1
3: Group 2

settings localShutdownDuration [time in seconds]

shutdownTriggers/ enabled true/false


powerOutage
capacityLessThan [percentage]

afterBackupTime [time in seconds]

startShutdownBeforeEndOf [time in seconds]


Backup

endShutdownBeforeEndOfB [time in seconds]


ackup

3.5.3.3.1 Additional information

For details on Save and Restore, see the Save and Restore section.

3.5.3.4 Troubleshooting

Action not allowed in Control/Schedule/Power outage policy

Symptom
Below message is displayed when you access the Control, Schedule or Power outage policy page.

This action is not allowed by the UPS.


To enable it, please refer to the user manual of the UPS and its instructions on how to configure the UPS settings and allow
remote commands.

Possible Cause
1- Remote commands are not allowed due to the UPS configuration (see the action below)
2- The UPS does not support remote commands.

Action
Refer to the UPS user manual and its instruction on how to configure the UPS settings and allow remote commands.
Example: UPS menu Settings>>>ON/OFF settings>>>Remote command>>>Enable.

Client server is not restarting

Contextual help of the web interface – 76


Environment

Symptom
Utility power has been restored, the UPS and its load segments are powered on, but the Client server does not restart.

Possible Cause
The “Automatic Power ON” server setup setting might be disabled.

Action
In the server system BIOS, change the setting for Automatic Power ON to "Enabled".

3.5.3.4.1 For other issues

For details on other issues, see the Troubleshooting section.

3.6 Environment
3.6.1 Commissioning/Status

3.6.1.1 Sensors commissioning/Status table


The table displays the sensors commissioning information and includes the following details.
• Name
• Location – location-position-elevation
• Temperature
• Humidity
• Dry contact #1 – Status and name
• Dry contact #2 – Status and name
• Communication – Connected/Lost with dates

3.6.1.2 Actions

3.6.1.2.1 Download sensors measures

Press the Download sensors measures button to download the sensors log file:
If available, possible measures are listed below:
• Temperature of <sensor_1> (in K, 1 decimal digit)
• Humidity of <sensor_1> (in %, 1 decimal digit)
• Temperature of <sensor_2>> (in K, 1 decimal digit)
• Humidity of <sensor_2> (in %, 1 decimal digit)
• Temperature of <sensor_3> (in K, 1 decimal digit)
• Humidity of <sensor_3> (in %RH, 1 decimal digit)

°C = K - 273.15
°F = K x 9/5 -459.67

Contextual help of the web interface – 77


Environment

3.6.1.2.2 Discover
At first the table is empty, press the Discover button to launch the sensor discovery process.
If sensors are discovered, the table is populated accordingly

3.6.1.2.3 Delete
Select a sensor and press the Delete button to delete the sensor.

When a sensor is deleted, all the commissioning information are deleted.

3.6.1.2.4 Define offsets

1. Select the sensors.


2. Press the Define offset button to adjust the temperature and humidity offsets of the selected sensors.
3. Extend the temperature or humidity section.
4. Set the offsets in the cell, temperatures and humidity will be updated accordingly.
5. Press the Save button when done.

Deactivated humidity or temperatures are not displayed and replaced by this icon:

Contextual help of the web interface – 78


Environment

3.6.1.2.5 Edit

Press the pen logo to edit sensor communication information:


You will get access to the following information and settings:
• Product reference
• Part number
• Serial number
• Name
• Location
• Temperature and humidity – Active (Yes, No)
• Dry contacts – Active (Yes, No)/Name/Polarity (Normally open, Normally closed)

The dry contact is close and this is normal because it is configured as normally close.

The dry contact is open and this is normal because it is configured as normally open.

The dry contact is open and this is not normal because it is configured as normally close.

The dry contact is close and this is not normal because it is configured as normally open.

Contextual help of the web interface – 79


Environment

Press Save after modifications.

Deactivated dry contacts are not displayed and replaced by this icon:

3.6.1.3 Note:
If the UPS provides temperature compensated battery charging option, see the Servicing the EMP>>>Using the
EMP for temperature compensated battery charging section.

3.6.1.4 Access rights per profiles


Administrator Operator Viewer

Environment/Commissioning

Environment/Status

3.6.1.4.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.6.1.5 Troubleshooting

EMP communication status shows "Lost"

In the Network Module, in Contextual help>>>Environment>>>Commissioning/Status , EMPs are missing in the Sensor
commissioning table.

Symptom #1
The connection status of the sensor is "Lost"

Possible causes
The EMPs are not powered by the Network module.

Action #1-1
Launch again the discovery, if it is still not ok, go to Action #1-2.

Action #1-2
1- Check the EMPs connection and cables.
Refer to the sections Servicing the EMP>>>Installing the EMP>>>Cabling the first EMP to the device and Servicing the
EMP>>>Installing the EMP>>>Daisy chaining 3 EMPs .
2- Disconnect and reconnect the USB to RS485 cable.
3- Launch the discovery, if it is still not ok, go to Action #1-3.

Contextual help of the web interface – 80


Environment

Action #1-3
1- Reboot the Network module.
2- Launch the discovery.

EMP detection fails at discovery stage

In the Network Module, in Contextual help>>>Environment>>>Commissioning/Status , EMPs are missing in the Sensor
commissioning table.

Symptom #1
The EMPs green RJ45 LED (FROM DEVICE) is not ON.

Possible causes
The EMPs are not powered by the Network module.

Action #1-1
Launch again the discovery, if it is still not ok, go to Action #1-2.

Action #1-2
1- Check the EMPs connection and cables.
Refer to the sections Servicing the EMP>>>Installing the EMP>>>Cabling the first EMP to the device and Servicing the
EMP>>>Installing the EMP>>>Daisy chaining 3 EMPs .
2- Disconnect and reconnect the USB to RS485 cable.
3- Launch the discovery, if it is still not ok, go to Action #1-3.

Action #1-3
1- Reboot the Network module.
2- Launch the discovery.

Symptom #2
The EMPs orange RJ45 LEDs are not blinking.

Possible causes
C#1: the EMP address switches are all set to 0.
C#2: the EMPs are daisy chained, the Modbus address is the same on the missing EMPs.

Action #2-1
1- Change the address of the EMPs to have different address and avoid all switches to 0.
Refer to the section Servicing the EMP>>>Defining EMPs address and termination>>>Manual addressing .
2- Disconnect and reconnect the USB to RS485 cable. The address change is only taken into account after an EMP power-up.
3- Launch the discovery, if it is still not ok, go to Action #2-2.

Contextual help of the web interface – 81


Environment

Action #2-2
1- Reboot the Network module.
Refer to the section Contextual help>>>Maintenance>>>Services>>>Reboot .
2- Launch the discovery.

3.6.1.5.1 For other issues

For details on other issues, see the Troubleshooting section.

3.6.2 Alarm configuration

Humidity, temperatures or dry contacts deactivated during commissioning are not displayed.
Gauge color code:
• Green: Value inside thresholds.
• Orange/Red: Value outside thresholds.
• Grey: No thresholds provided by the device.

3.6.2.1 Temperature

The table shows the following information and settings for each sensor:
• Name
• Location
• Enabled – yes/no
• Low critical threshold – xx°C or xx°F
• Low warning threshold – xx°C or xx°F
• High warning threshold – xx°C or xx°F
• High critical threshold – xx°C or xx°F
• Hysteresis – x°C or x°F
• Visual update
• Live reading (MIN-MAX shows the minimal and maximal temperature measured by the sensor)

3.6.2.1.1 Actions

a Set Enabled
Select and directly change the setting in the table and then Save.
When disabled, no alarm will be sent.

Contextual help of the web interface – 82


Environment

b Set alarm threshold


Enable the alarm first and then change the setting in the table and then Save.
When a warning threshold is reached, an alarm will be sent with a warning level.
When a critical threshold is reached, an alarm will be sent with a critical level.

c Set Hysteresis
Enable the alarm first and change the setting in the table and then Save.
The hysteresis is the difference between the value where the alarm turns ON from turning OFF and the value where it turns OFF
from turning ON.

3.6.2.2 Humidity

The table shows the following information and settings for each sensor:
• Name
• Location
• Enabled – yes/no
• Low critical threshold – xx%
• Low warning threshold – xx%
• High warning threshold – xx%
• High critical threshold – xx%
• Hysteresis – x%
• Visual update
• Live reading (MIN-MAX shows the minimal and maximal humidity measured by the sensor)

3.6.2.2.1 Actions

a Set Enabled
Select and directly change the setting in the table and then Save.
When disabled, no alarm will be sent.

b Set alarm threshold


Enable the alarm first and then change the setting in the table and then Save.
When a warning threshold is reached, an alarm will be sent with a warning level.
When a critical threshold is reached, an alarm will be sent with a critical level.

c Set Hysteresis
Enable the alarm first and then change the setting in the table and then Save.
The hysteresis is the difference between the value where the alarm turns ON from turning OFF and the value where it turns OFF
from turning ON.

Contextual help of the web interface – 83


Environment

3.6.2.3 Dry contacts

The table shows the following settings for each dry contact:
• Name
• Location
• Enabled – yes/no
• Alarm severity – Info/Warning/Critical

3.6.2.3.1 Actions

a Set Enabled
Enable the alarm first and then change the setting in the table and then Save.
When disabled, no alarm will be sent.

b Set alarm severity


Enable the alarm first and then change the setting in the table and then Save.
When the dry contacts is not in a normal position, an alarm will be sent at the selected level.

The dry contact is open and this is not normal because it is configured as normally close.

The dry contact is close and this is not normal because it is configured as normally open.

3.6.2.4 Default settings and possible parameters - Environment Alarm configuration


Default setting Possible parameters

Temperature Enabled — No Enabled — No/Yes


Low critical – 0°C/32°F low critical<low warning<high warning<high critical
Low warning – 10°C/50°F
High warning – 70°C/158°F
High critical – 80°C/176°F

Humidity Enabled — No Enabled — No/Yes

Contextual help of the web interface – 84


Environment

Low critical – 10% 0%<low critical<low warning<high warning<high


critical<100%
Low warning – 20%
High warning – 80%
High critical – 90%

Dry contacts Enabled — No Enabled — No/Yes


Alarm severity – Warning Alarm severity – Info/Warning/Critical

3.6.2.4.1 For other settings

For other settings, see the Information>>>Default settings parameters section.

3.6.2.5 Access rights per profiles


Administrator Operator Viewer

Environment/Alarm
configuration

3.6.2.5.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.6.3 Information
Sensor information is an overview of all the sensors information connected to the Network Module.

Contextual help of the web interface – 85


Settings

• Physical name
• Vendor
• Part number
• Firmware version
• UUID
• Serial number
• Location

3.6.3.1 Access rights per profiles


Administrator Operator Viewer

Environment/Information

3.6.3.1.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.7 Settings
3.7.1 General

3.7.1.1 System details

3.7.1.1.1 Location
Text field that is used to provide the card location information.

Contextual help of the web interface – 86


Settings

Card system information is updated to show the defined location.

3.7.1.1.2 Contact
Text field that is used to provide the contact name information.
Card system information is updated to show the contact name.

3.7.1.1.3 System name


Text field that is used to provide the system name information.
Card system information is updated to show the system name.

3.7.1.2 Date & Time

The current date and time appears at the top of the screen.
You can set the time either manually or automatically.

Contextual help of the web interface – 87


Settings

3.7.1.2.1 Manual mode: Manually entering the date and time

1. Select the time zone for your geographic area.


2. Select the date and time.
3. Save the changes.

3.7.1.2.2 Dynamic (NTP): Synchronizing the date and time with an NTP server

1. Select the time zone for your geographic area.


2. Enter the IP address or host name of the NTP servers in the NTP server fields (up to 5 servers).
3. Save the changes.

Contextual help of the web interface – 88


Settings

3.7.1.2.3 Dynamic (NTP): Synchronizing the date and time from the DHCP server

1. Select the time zone for your geographic area.


2. Select Get NTP server from DHCP
3. Save the changes.

DST is managed based on the time zone.

3.7.1.3 Email notification settings

For examples on email sending configuration see the Servicing the Network Management Module>>>Subscribing
to a set of alarms for email notification section.

3.7.1.3.1 Email sending configuration table


The table shows all the email sending configuration and includes the following details:

Contextual help of the web interface – 89


Settings

• Configuration name
• Email address
• Notification updates – Displays Events notification/Periodic report icons when active.
• Status – Active/Inactive/In delegation

3.7.1.3.2 Actions

a Add
Press the New button to create a new email sending configuration.

b Remove
Select an email sending configuration and press the Delete button to remove it.

c Edit

Press the pen icon to edit email sending configuration:


You will get access to the following settings:
• Custom name

Contextual help of the web interface – 90


Settings

• Email address
• Status – Active/Inactive
• Hide the IP address from the email body – Disabled/Enabled
This setting will be forced to Enabled if Enabled in the SMTP settings.
• Schedule report – Active/Recurrence/Starting/Topic selection – Card/Devices

Attachment will contains only logs that have occurred during the recurrence.

• Alarm notifications – Severity level/Attach logs/Exceptions on events notification

Contextual help of the web interface – 91


Settings

3.7.1.4 SMTP settings

SMTP is an internet standard for electronic email transmission.


The following SMTP settings are configurable:

Contextual help of the web interface – 92


Settings

• Server IP/Hostname – Enter the host name or IP address of the SMTP server used to transfer email messages in the SMTP
Server field.
• Port
• Default sender address
• Hide the IP address from the email body – Disabled/Enabled
If Enabled, it will force this setting to Enabled in the Email notification settings.
• Secure SMTP connection – Verify certificate authority
• SMTP server authentication – Username/Password ( Read below note for Gmail Configuration regarding the password )
Select the SMTP server authentication checkbox to require a user name and a password for SNMP authentication, enter the
Username and the Password.

Gmail Users
Google no more allow the card to send email using your Gmail account password, but requires you to use a
dedicated "App passwords" instead.

To proceed, you need first to enable a 2-Step Verification on your Google account.
Then you need to follow these steps to generate an "App password" that you'll be required to configure SMTP
server authentication in the card (instead of your google account usual password):
1. Go to https://security.google.com/settings/security/apppasswords and sign in to your account.
2. Choose Mail from the list of available apps.
3. Choose Other from the device list.
4. Enter your Custom Name. You can put any name such as ”my-card" in it.
5. Click the Generate button.
6. Copy the password and put in the password field. ( The same password can be reused across multiple
cards)
Be careful, this password cannot be recovered after clicking the "Done" button. If lost, you'll have to
regenerate a new password & reapply it in the settings.
7. Click the Done button, and that’s it.

• Save and test server configuration

3.7.1.5 Default settings and possible parameters - General


Default setting Possible parameters

System details Location — empty Location — 31 characters maximum


Contact — empty Contact — 255 characters maximum
System name — empty System name — 255 characters maximum
Time & date settings — Manual (Time zone: Europe/ Time & date settings — Manual (Time zone: selection on
Paris) map/Date) / Dynamic (NTP)

Email notification settings No email 5 configurations maximum


Custom name — 128 characters maximum
Email address — 128 characters maximum
Hide IP address from the email body — enable/disabled
Status — Active/Inactive

• Alarm notifications
Active — No/Yes
All card events – Subscribe/Attach logs
Critical alarm – Subscribe/Attach logs
Warning alarm – Subscribe/Attach logs
Info alarm – Subscribe/Attach logs

All device events – Subscribe/Attach


measures/Attach logs
Critical alarm – Subscribe/Attach measures/

Contextual help of the web interface – 93


Settings

Attach logs
Warning alarm – Subscribe/Attach measures/
Attach logs
Info alarm – Subscribe/Attach measures/
Attach logs

Always notify events with code


Never notify events with code

• Schedule report
Active — No/Yes
Recurrence – Every day/Every week/Every
month
Starting – Date and time
Card events – Subscribe/Attach logs
Device events – Subscribe/Attach measures/
Attach logs

SMTP settings Server IP/Hostname — blank Server IP/Hostname — 128 characters maximum
SMTP server authentication — disabled SMTP server authentication — disable/enable
(Username/Password — 128 characters maximum)
Port — 25
Port — x-xxx
Default sender address — [email protected]
Sender address — 128 characters maximum
Hide IP address from the email body — disabled
Hide IP address from the email body — enable/disabled
Security — enabled
Secure SMTP connection — enable/disable
Verify certificate authority — disabled
Verify certificate authority — disable/enable
SMTP server authentication — disabled

3.7.1.5.1 For other settings

For other settings, see the Information>>>Default settings parameters section.

3.7.1.6 Access rights per profiles


Administrator Operator Viewer

General

3.7.1.6.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.7.1.7 CLI commands

email-test

Description
mail-test sends test email to troubleshoot SMTP issues.

Contextual help of the web interface – 94


Settings

Help

Usage: email-test <command> ...


Test SMTP configuration.

Commands:
email-test -h, --help, Display help page

email-test -r, --recipient <recipient_address>


Send test email to the
<recipient_address> Email address of the recipient

time

Description
Command used to display or change time and date.

Help
For Viewer and Operator profiles:

time -h
Usage: time [OPTION]...
Display time and date.

-h, --help display help page


-p, --print display date and time in YYYYMMDDhhmmss format

For Administrator profile:

time -h
Usage: time [OPTION]...
Display time and date, change time and date.
-h, --help display help page
-p, --print display date and time in YYYYMMDDhhmmss format
-s, --set <mode>
Mode values:
- set date and time (format YYYYMMDDhhmmss)
manual <date and time>
- set preferred and alternate NTP servers
ntpmanual <preferred server> <alternate server>
- automatically set date and time
ntpauto
Examples of usage:
-> Set date 2017-11-08 and time 22:00
time --set manual 201711082200

Contextual help of the web interface – 95


Settings

-> Set preferred and alternate NTP servers


time --set ntpmanual fr.pool.ntp.org de.pool.ntp.org

Examples of usage

-> Set date 2017-11-08 and time 22:00


time --set manual 201711082200
-> Set preferred and alternate NTP servers
time --set ntpmanual fr.pool.ntp.org de.pool.ntp.org

3.7.1.7.1 For other CLI commands

See the CLI commands in the Information>>>CLI section.

3.7.1.8 Save and Restore


SRR section SRR sub section Settings Sub Setttings Possible values

System details card identification name String: refer to default


settings and possible
parameters for constraints.

contact String: refer to default


settings and possible
parameters for constraints.

location String: refer to default


settings and possible
parameters for constraints.

Time and Date settings date ntp enabled true/false

getServersFromDhcp true/false

servers preferredServer *

alternateServer *

timeZone Examples:
Europe/Paris
Africa/Johannesburg
America/New_York
Asia/Shanghai

Email email notifyOnEvents enabled true/false

cardEvents critical
subscribe true/false
attachEventsLog true/false

Contextual help of the web interface – 96


Settings

warning
subscribe true/false
attachEventsLog true/false

info
subscribe true/false
attachEventsLog true/false

devicesEvents critical
subscribe true/false
attachEventsLog true/false
attachMeasuresLog true/false
warning
subscribe true/false
attachEventsLog true/false
attachMeasuresLog true/false
info
subscribe true/false
attachEventsLog true/false
attachMeasuresLog true/false

exceptions notifiedEvents evenst codes separated by


coma
evenst codes separated by
noneNotifiedEvents coma

periodicReport enabled true/false


periodicity Every day/week/month
startTime Unix timestamp

card subscribe true/false


attachEventsLog true/false

devices subscribe true/false


attachEventsLog true/false
attachMeasuresLog true/false

message sender String: refer to default


settings and possible
parameters for constraints.

subject String: refer to default


settings and possible
parameters for constraints.

hideIpAddress true/false

SMTP smtp certificateData ca Certificate Authority of


SMTP server

port Number: refer to default


settings and possible
parameters for constraints.

enabled true/false

Contextual help of the web interface – 97


Settings

server IP address or hostname of


SMTP server

requireAuth true/false

user Username for server


authentication

password plaintext String: refer to default


settings and possible
parameters for constraints.
cyphered -

fromAddress email address format

ssl 1: None
2: STARTTLS
3: SSL

verifyTlsCert true/false

3.7.1.8.1 Additional information

For details on Save and Restore, see the Save and Restore section.

3.7.2 Local users

3.7.2.1 Local users table

The table shows all the supported local user accounts and includes the following details:
• Username
• Email
• Profile
• Status – Status could take following values – Inactive/Locked/Password expired/Active

For the list of access rights per profile refer to the section Full documentation>>>Information>>>Access rights per
profiles.

Contextual help of the web interface – 98


Settings

3.7.2.1.1 Actions

a Add
Press the New button to add new local users.

You can add up to 20 local users. Kindly note that above 10 users connected simultaneously, it is likely to consume
a lot of CPU resources resulting in slower card performance.

b Remove
Select a user and press the Delete button to remove it.

c Edit

Press the pen logo to edit user information:


You will get access to the following settings:
• Active
• Profile
• Username
• Full name
• Email
• Phone
• Organization – Notify by email about account modification/Password
• Reset password
• Generate randomly
• Enter manually
• Force password to be changed on next login

Contextual help of the web interface – 99


Settings

d Global settings

Press Save after modifications.


Password settings
To set the password strength rules, apply the following restrictions:
• Minimum length
• Minimum upper case
• Minimum lower case
• Minimum digit
• Special character
Password expiration
To set the password expiration rules, apply the following restrictions:
• Number of days until password expires
• Main administrator password never expire

Contextual help of the web interface – 100


Settings

Main administrator password never expires


1. If this feature is disabled, the administrator account can be locked after the password expiration.
2. If Enabled, the administrator password never expires, make sure it is changed regularly.

Lock account
• Lock account after a number of invalid tries
• Main administrator account will never block

Main administrator account will never block


1. If this feature is disabled, the administrator account can be locked after the number of failed connections
defined.
2. If Enabled, the security level of the administrator account is reduced because unlimited password entry
attempts are allowed.

Account timeout
To set the session expiration rules, apply the following restrictions:
• No activity timeout (in minutes).
If there is no activity, session expires after the specified amount of time.
• Session lease time (in minutes).
If there is activity, session still expires after the specified amount of time.

Main administrator password never expires


When new settings are set, parameters will be taken into account on their next connection to the card.

3.7.2.2 Default settings and possible parameters - Global user settings and Local
users
Default setting Possible parameters

Password settings Minimum length — enabled (8) Minimum length — enable (6-32)/disable
Minimum upper case — enabled (1) Minimum upper case — enable (0-32)/disable
Minimum lower case — enabled (1) Minimum lower case — enable (0-32)/disable
Minimum digit — enabled (1) Minimum digit — enable (0-32)/disable
Special character — enabled (1) Special character — enable (0-32)/disable

Password expiration Number of days until password expires — disabled Number of days until password expires — disable/
enable (1-99999)
Main administrator password never expires — disabled
Main administrator password never expires — disable/
enable

Lock account Lock account after xx invalid tries — disabled Lock account after xx invalid tries — disable/enable
(1-99)
Main administrator account never blocks — disabled
Main administrator account never blocks — disable/
enable

Account timeout No activity timeout — 60 minutes No activity timeout — 1-60 minutes


Session lease time — 120 minutes Session lease time — 60-720 minutes

Local users 1 user only: 20 users maximum:

• Active — Yes • Active — Yes/No


• Profile — Administrator • Profile — Administrator/Operator/Viewer
• Username — admin • Username — 255 characters maximum

Contextual help of the web interface – 101


Settings

• Full Name — blank • Full Name — 128 characters maximum


• Email — blank • Email — 128 characters maximum
• Phone — blank • Phone — 64 characters maximum
• Organization — blank • Organization — 128 characters maximum

3.7.2.2.1 For other settings

For other settings, see the Information>>>Default settings parameters section.

3.7.2.3 Access rights per profiles


Administrator Operator Viewer

Local users

3.7.2.3.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.7.2.4 CLI commands

whoami

Description
whoami displays current user information:
• Username
• Profile
• Realm

logout

Description
Logout the current user.

Help

logout
<cr> logout the user

Contextual help of the web interface – 102


Settings

3.7.2.4.1 For other CLI commands

See the CLI commands in the Information>>>CLI section.

3.7.2.5 Troubleshooting

How do I log in if I forgot my password?

Action

• Ask your administrator for password initialization.


• If you are the main administrator, your password can be reset manually by following steps described in the Servicing
the Network Management Module>>>Recovering main administrator password .

3.7.2.5.1 For other issues

For details on other issues, see the Troubleshooting section.

3.7.2.6 Save and Restore


SRR section SRR sub section Settings Possible values

Password settings accountService passwordRules strength


minLengthminUpperCase Numbers: refer to default
settings an possible parameters
minLowerCase for constraints.
minDigit
minSpecialCharacter

Password expiration expiration


expiration enabled true/false
afterDays Number: refer to default settings
an possible parameters for
defaultAccountNeverExpires constraints.
true/false

Lock account lockoutRules lockoutRules


enabled true/false
threshold Number: refer to default settings
an possible parameters for
defaultAccountNeverBlocks constraints.
true

Account timeout sessionsService sessionTimeout Numbers: refer to default


settings an possible parameters
sessionLeaseTime for constraints.

Local users PredefinedAccounts credentials

Contextual help of the web interface – 103


Settings

enabled true/false
username String: refer to default settings
an possible parameters for
passwordExpired constraints.
locked true/false
profile true/false
password administrators/operators/viewers
plaintext
cyphered String: refer to default settings
an possible parameters for
constraints.
-

3.7.2.6.1 Additional information

For details on Save and Restore, see the Save and Restore section.

3.7.3 Remote users

3.7.3.1 LDAP

The table shows all the supported severs and includes the following details:
• Name
• Address
• Port
• Security
• Certificate
• Status – Status could take following values – Unreachable/Active

Contextual help of the web interface – 104


Settings

3.7.3.1.1 Actions

a Configure

1.Enable LDAP to be able to configure settings


2. Press Configure to access the following LDAP settings:
• Connectivity
• Security
SSL – None/Start TLS/SSL
Verify server certificate
• Primary server – Name/Hostname/Port
• Secondary server – Name/Hostname/Port
• Credentials – Anonymous search bind/Search user DN/Password
• User base DN
• User name attribute
• Group base DN
• Group name attribute
2. Click Save.

Contextual help of the web interface – 105


Settings

b Profile mapping

For the list of access rights per profile refer to the section Full documentation>>>Information>>>Access rights per
profiles.

1. Press Profile mapping to map remote groups to local profiles.


2. Click Save.

c Users preferences

All users preferences will apply to all remote users (LDAP, RADIUS).

Contextual help of the web interface – 106


Settings

1. Press Users preferences to define preferences that will apply to all newly logged in LDAP users
• Language
• Temperature
• Date format
• Time format
2. Click Save.

Contextual help of the web interface – 107


Settings

d LDAP Test

1. At the end of each LDAP primary or secondary configuration row you'll be able to launch a LDAP test by clicking on the button.
2. The LDAP test will give you a status ( ok / ko ) on below parameters to make it easier to troubleshoot
• Primary
• Bind
• User domain dn
• User name attribute
• Group domain dn
• Group name attribute
• Mapped profile
• Credentials
3. Click Test to check your configuration.

3.7.3.2 RADIUS
Radius is not a secured protocol, for a maximum security, it is recomended to use LDAP over TLS.

Contextual help of the web interface – 108


Settings

The table shows all the supported severs and includes the following details:
• Name - descriptive name for the RADIUS server
• Address - hostname or IP address for the RADIUS server
• Port - connection port of the RADIUS Server

3.7.3.2.1 Actions

a Configure

1. Enable Radius to be able to configure settings


2. Press Configure to access the following RADIUS settings:
• Primary server
• Name - descriptive name for the RADIUS server
• Secret - a shared secret between the client and the RADIUS server

Contextual help of the web interface – 109


Settings

• Address - hostname or IP address for the RADIUS server


• UDP port - the UDP port for the RADIUS server (1812 by default)
• Time out (s) - length of time the client waits for a response from the RADIUS server
• Retry count - the number of time a connection is retried
• Secondary server
• Name - descriptive name for the RADIUS server
• Secret - a shared secret between the client and the RADIUS server
• Address - hostname or IP address for the RADIUS server
• UDP port - the UDP port for the RADIUS server (1812 by default)
• Time out (s) - length of time the client waits for a response from the RADIUS server
• Retry count - the number of time a connection is retried
• NAS
• Identifier - descriptive identifier for the radius server to identify the device
• IP - IP address of the card or a domain name ( FQDN )

Note: The radius protocol supported by the card is PAP

2. Click Save.

b Profile mapping

Contextual help of the web interface – 110


Settings

For the list of access rights per profile refer to the section Full documentation>>>Information>>>Access rights per
profiles.

1. Press Profile mapping to map RADIUS profile to local profiles.

Default Profile
You can enable & define a default profile for all Radius that are not subject to any specific rules (see below).

Specific Rules
Fill the usual triplet of information as per your radius configuration:
• Attribute - The attribute value - Mandatory
• Vendor - The vendor value associated to the attribute - Mandatory ( 0 as default value )
• Value - The value of the attribute needed for this mapping - Mandatory
Fill the profile you want your specific radius configuration to be mapped with
• Profile - the local profile you want users to be mapped
Note: The default mapping is used for eaton-specific value : Attribute 28, Vendor 534, Value 1 and Profile administrator.Please refer
to your RADIUS protocol provider documentation for further information.
2. Click Save.

c Users preferences

1. Press Users preferences to define preferences that will apply to all RADIUS users
• Language
• Temperature
• Date format
• Time format
2. Click Save.

Contextual help of the web interface – 111


Settings

3.7.3.3 Default settings and possible parameters - Remote users


Default setting Possible parameters

LDAP Configure Configure

• Active – No • Active – No/yes


• Security • Security
SSL – SSL SSL – None/Start TLS/SSL
Verify server certificate – enabled Verify server certificate – disabled/enabled
• Primary server • Primary server
Name – Primary Name – 128 characters maximum
Hostname – blank Hostname – 128 characters maximum
Port – 636 Port – x-xxx
• Secondary server • Secondary server
Name – blank Name – 128 characters maximum
Hostname – blank Hostname – 128 characters maximum
Port – blank Port – x-xxx
• Credentials • Credentials
Anonymous search bind – disabled Anonymous search bind – disabled/enabled
Search user DN – blank Search user DN – 1024 characters
Password – blank maximum
• Search base Password – 128 characters maximum
Search base DN – dc=example,dc=com • Search base
• Request parameters Search base DN – 1024 characters
User base DN – maximum
ou=people,dc=example,dc=com • Request parameters
User name attribute – uid User base DN – 1024 characters maximum
UID attribute – uidNumber
Group base DN – User name attribute – 1024 characters
ou=group,dc=example,dc=com maximum
Group name attribute – gid UID attribute – 1024 characters maximum
GID attribute – gidNumber Group base DN – 1024 characters maximum
Profile mapping – no mapping
Group name attribute – 1024 characters
Users preferences maximum
GID attribute – 1024 characters maximum
• Language – English
• Temperature unit – °C (Celsius) Profile mapping – up to 5 remote groups mapped to
• Date format – m/d/Y local profiles
• Time format – hh:mm:ss (24h) Users preferences

• Language – English, French, German, Italian,


Japanese, Russian, Simplified Chinese,
Spanish, Traditional Chinese
• Temperature unit – °C (Celsius)/°F
(Fahrenheit)
• Date format – MM-DD-YYYY / YYY-MM-
DD / DD-MM-YYY / DD.MM.YYY / DD/MM/
YYY / DD MM YYYY
• Time format – hh:mm:ss (24h) / hh:mm:ss
(12h)

RADIUS Configure Configure

• Active – No • Active – Yes/No


• Retry number – 0 • Retry number – 0 to 128
• Primary server • Primary server
Name – blank Name – 128 characters maximum
Secret – blank Address – 128 characters maximum
Address – blank Secret – 128 characters maximum
UDP port – 1812 UDP port – 1 to 65535
Time out – 3 Time out – 3 to 60

Contextual help of the web interface – 112


Settings

• Secondary server • Secondary server


Name – blank Name – 128 characters maximum
Secret – blank Address – 128 characters maximum
Address – blank Secret – 128 characters maximum
UDP port – 1812 UDP port – 1 to 65535
Time out – 3 Time out – 3 to 60
Users preferences Users preferences

• Language – English • Language – English, French, German, Italian,


• Temperature unit – °C (Celsius) Japanese, Russian, Simplified Chinese,
• Date format – m/d/Y Spanish, Traditional Chinese
• Time format – hh:mm:ss (24h) • Temperature unit – °C (Celsius)
• Date format – MM-DD-YYYY
• Time format – hh:mm:ss (24h)

3.7.3.3.1 For other settings

For other settings, see the Information>>>Default settings parameters section.

3.7.3.4 Access rights per profiles


Administrator Operator Viewer

Remote users

3.7.3.4.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.7.3.5 CLI commands

ldap-test

Description
Ldap-test help to troubleshoot LDAP configuration issues or working issues.

Help

Usage: ldap-test <command> [OPTION]...


Test LDAP configuration.

Commands:
ldap-test -h, --help, Display help page

ldap-test --checkusername <username> [--primary|--secondary] [-v]


Check if the user can be retrieve from the LDAP server
<username> Remote username to test
--primary Force the test to use primary server (optional)
--secondary Force the test to use secondary server (optional)
-v,--verbose Print the exchanges with LDAP server (optional)

Contextual help of the web interface – 113


Settings

ldap-test --checkauth <username> [--primary|--secondary] [-v]


Check if remote user can login to the card
<username> Remote username to test
-p,--primary Force the test to use primary server (optional)
-s,--secondary Force the test to use secondary server (optional)
-v,--verbose Print the exchanges with LDAP server (optional)

ldap-test --checkmappedgroups [--primary|--secondary] [-v]


Check LDAP mapping
-p,--primary Force the test to use primary server (optional)
-s,--secondary Force the test to use secondary server (optional)
-v,--verbose Print the exchanges with LDAP server (optional)

Quick guide for testing:

In case of issue with LDAP configuration, we recommend to verify the


configuration using the commands in the following order:

1. Check user can be retrieve on the LDAP server


ldap-test --checkusername <username>

2. Check that your remote group are mapped to the good profile
ldap-test --checkmappedgroups

3. Check that the user can connect to the card


ldap-test --checkauth <username>

logout

Description
Logout the current user.

Help

logout
<cr> logout the user

whoami

Description
whoami displays current user information:

Contextual help of the web interface – 114


Settings

• Username
• Profile
• Realm

3.7.3.5.1 For other CLI commands

See the CLI commands in the Information>>>CLI section.

3.7.3.6 Troubleshooting

How do I log in if I forgot my password?

Action

• Ask your administrator for password initialization.


• If you are the main administrator, your password can be reset manually by following steps described in the Servicing
the Network Management Module>>>Recovering main administrator password .

LDAP configuration/commissioning is not working

Refer to the section Servicing the Network Management Module>>>Commissioning/Testing LDAP .

3.7.3.6.1 For other issues

For details on other issues, see the Troubleshooting section.

3.7.3.7 Save and Restore


SRR Sub Sub section Sub section Sub section Settings Sub settings Possible values
section section

LDAP ldap 1.0 settings enabled true/false

connectivity primaryServ name String: refer to default


er settings an possible
parameters for
constraints.

uri String: refer to default


settings an possible
parameters for
constraints.

port Unsigned number

secondarySe name String: refer to default


rver settings an possible

Contextual help of the web interface – 115


Settings

parameters for
constraints.

uri String: refer to default


settings an possible
parameters for
constraints.

port Unsigned number

userDomain nameAttribute String: refer to default


settings an possible
parameters for
constraints.

dn String: refer to default


settings an possible
parameters for
constraints.

groupDomai nameAttribute String: refer to default


n settings an possible
parameters for
constraints.

dn String: refer to default


settings an possible
parameters for
constraints.

bind dn String: refer to default


settings an possible
parameters for
constraints.

password plaintext String: refer to default


settings an possible
parameters for
constraints.

ciphered String: refer to default


settings an possible
parameters for
constraints.

security type 1: ssl


2: starttls
3: none

verifyCertificate true/false

mappings remoteGroup String: refer to default


settings an possible
parameters for
constraints.

profileName • administrators
• viewers
• operators

preferences language String: refer to default


settings an possible
parameters for
constraints.

Contextual help of the web interface – 116


Settings

dateFormat String: refer to default


settings an possible
parameters for
constraints.

timeFormat String: refer to default


settings an possible
parameters for
constraints.

temperatureUnit String: refer to default


settings an possible
parameters for
constraints.

licenceAgreement String: refer to default


settings an possible
parameters for
constraints.

SRR Sub Sub section Sub section Sub section Settings Sub settings Possible values
section section

RADIUS radius 1.0 settings enabled true/false

protocol pap
connectivity chap

primaryServe name String: refer to default


r settings an possible
parameters for
constraints.

secret String: refer to default


settings an possible
parameters for
constraints.

uri String: refer to default


settings an possible
parameters for
constraints.

port Unsigned number

timeout Unsigned number

retryCount Unsigned number

secondarySe name String: refer to default


rver settings an possible
parameters for
constraints.

secret String: refer to default


settings an possible
parameters for
constraints.

uri String: refer to default


settings an possible
parameters for
constraints.

port Unsigned number

Contextual help of the web interface – 117


Settings

timeout Unsigned number

retryCount Unsigned number

nas identifier String: refer to default


settings an possible
parameters for
constraints.

ip String: refer to default


settings an possible
parameters for
constraints.

mappings profile String: refer to default


settings an possible
parameters for
constraints.

attribute Number

value Number

vendor Number

preferences language String: refer to default


settings an possible
parameters for
constraints.

dateFormat String: refer to default


settings an possible
parameters for
constraints.

timeFormat String: refer to default


settings an possible
parameters for
constraints.

temperatureUnit String: refer to default


settings an possible
parameters for
constraints.

licenceAgreement String: refer to default


settings an possible
parameters for
constraints.

3.7.3.7.1 Additional information

For details on Save and Restore, see the Save and Restore section.

Contextual help of the web interface – 118


Settings

3.7.4 Protocols

3.7.4.1 Remote Monitoring Services

This tile allows an administrator to configure and enable the Remote monitoring services on the Network Module.

To configure the remote monitoring connection settings:


1- Enable the Remote monitoring services
2- Configure the Proxy if needed.
3- Configure Advanced settings if so advised by the service support and Save after modifications.

Contextual help of the web interface – 119


Settings

4- Save after modifications, a disclaimer will appear.

3.7.4.1.1 Status

Label Description

Connected The Network Module is connected and registered to the Remote Monitoring Service.
Data transmission is OK.

Disabled The Remote Monitoring Services is disabled.


To enable it, you must have a valid service contract. Please contact the local service team and enable the
Remote Monitoring Services on the Network Module.

Not connected The Remote Monitoring Services is enabled, the Network Module is not connected to it but connection
procedure has started.

Connecting The Network Module is connecting to the Remote Monitoring Services:

• DNS is set correctly


• Proxy is set correctly
• Certificate verification is OK

Contextual help of the web interface – 120


Settings

Label Description

Pending approval The Network Module is connected to the Remote Monitoring Services but not registered to it.
The Network Module must be registered by the service team in the Remote Monitoring Services.

Connection lost The Network Module has lost the connection to the Remote Monitoring Services and will try to reconnect
automatically.

DNS name resolution error The Network Module connection to the Remote Monitoring Services has failed.

• DNS is not set correctly or connection to it fails


Items to check with your network administrator:

• DNS setting in the Network Module


• DNS provided by the DHCP is working
• DNS address in the Network Module is correct
Troubleshooting:

• Switch to static DNS settings to troubleshoot

Proxy error The Network Module connection to the Remote Monitoring Services has failed.

• Proxy is not set correctly in the network module or the proxy service does not allow this
connection.
Items to check with your network administrator:

• Proxy URL is correctly set in the Network Module


• Proxy allows connection to the Internet
• Proxy allows HTTPs connections to the Internet
• Proxy does not use a custom certificate to intercept traffic
Troubleshooting:

• Reboot the Network Module if above checking is OK and contact the service representative if
it still is not working.

Certificate error The Network Module connection to the Remote Monitoring Services has failed.

• Certificate verification failed


Items to check with your network administrator:

• Proxy does not use a custom certificate to intercept traffic


Troubleshooting:

• Reboot the Network Module if above checking is OK and contact the service representative if
it still is not working.

Invalid credentials The Network Module connection to the Remote Monitoring Services has failed.

• Authentication has failed


The Network Module is using invalid username/password to connect to the Remote Monitoring Services.
Items to check with your service contact:

• Credentials set in the Network Module Advanced settings are correct.


Troubleshooting:

• If above checking is OK, contact the service representative.

Connection error The Network Module connection to the Remote Monitoring Services has failed for another error.
Troubleshooting:

• Contact the service representative.

Contextual help of the web interface – 121


Settings

3.7.4.2 Access rights per profiles


Administrator Operator Viewer

Protocols

3.7.4.2.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.7.4.3 Save and Restore


SRR section SRR sub section Settings Sub settings Possible values

Syslog rsyslog certificates ca *


trustedClient

Settings enabled true/false

servers name String: refer to default


settings an possible
parameters for
constraints.

enabled true/false

hostname String: refer to default


settings an possible
parameters for
constraints.

protocol 1: UDP
2: TCP

port Number: refer to


default settings an
possible parameters
for constraints.

tcpFraming 1: TRADITIONAL
2: OCTET_COUNTING

usingByteOrderMask true/false

security ssl *

verifyTlsCert true/false

name String: refer to default


settings an possible
parameters for
constraints.

enabled true/false

Contextual help of the web interface – 122


Settings

hostname String: refer to default


settings an possible
parameters for
constraints.

protocol 1: UDP
2: TCP

port Number: refer to


default settings an
possible parameters
for constraints.

tcpFraming 1: TRADITIONAL
2: OCTET_COUNTING

usingByteOrderMask true/false

security ssl *

verifyTlsCert true/false

3.7.4.3.1 Additional information

For details on Save and Restore, see the Save and Restore section.

3.7.5 SNMP
This tab contains settings for SNMP protocols used for network management systems.

Changes to authentication settings need to be confirmed by entering a valid password for the active user account.

3.7.5.1 SNMP tables


The default port for SNMP is 161 and normally this should not be changed. Some organizations prefer to use non-
standard ports due to cybersecurity, and this field allows that.

Contextual help of the web interface – 123


Settings

SNMP monitoring Battery status, power status, events, and traps are monitored using third-party SNMP managers.
To query SNMP data, you do not need to add SNMP Managers to the Notified Application page.
To set-up SNMP managers:
• Configure the IP address.
• Select SNMP v1/v2 or v3.
• Compile the MIB you selected to be monitored by the SNMP manager.
List of supported MIBs: xUPS MIB | ATS2 MIB | Standard IETF UPS MIB (RFC 1628) | Sensor MIB
Press the Supported MIBs button to download the MIBs.

3.7.5.1.1 Settings
This screen allows an administrator to configure SNMP settings for computers that use the MIB to request information from the
Network Module.
Default ports for SNMP are 161 (SNMP v1 and v3, set/get) and 162 (traps). These ports can be changed on the settings screen for
additional security.
To configure the SNMP settings:

a Enable the SNMP agent


In addition to this, v1/V2C and/or v3 must be enabled, along with appropriate communities and activated user accounts to allow
SNMP communication.
Press Save after modifications.

Contextual help of the web interface – 124


Settings

b Configure the SNMP V1/V2C settings:

1. Click the edit icon on either Read Only or Read/Write account to access settings:
2. Enter the SNMP Community Read-Only string. The Network Module and the clients must share the same community name to
communicate.
3. Select Active in the Enabled drop-down list to activate the account.
4. Access level is set to display information only.

Contextual help of the web interface – 125


Settings

c Configure the SNMP V3 settings:

1. Click the edit icon on either Read Only or Read/Write account to access settings:
2. Edit the user name.
3. Select Active in the Enabled drop-down list to activate the account.
4. Select access level.
• Read only—The user does not use authentication and privacy to access SNMP variables.
• Read/Write—The user must use authentication, but not privacy, to access SNMP variables.
5. Select the communication security mechanism.
• Auth, Priv—Communication with authentication and privacy.
• Auth, No Priv—Communication with authentication and without privacy.
• No Auth, No Priv—Communication without authentication and privacy.

Contextual help of the web interface – 126


Settings

6. If Auth is selected on the communication security mechanism, select the Authentication algorithms.

It is recommended to set SHA256/SHA384/SHA512 with the AES192/AES256 Privacy algorithms.

• SHA— SHA1 is not recommended as it is not secured.


• SHA256—fill in password and privacy keys. The password can be between 8 and 24 characters and use a combination of
alphanumeric and the following special characters <>&@#%_=:;,./?|$*.
• SHA384—fill in password and privacy keys. The password can be between 8 and 24 characters and use a combination of
alphanumeric and the following special characters <>&@#%_=:;,./?|$*.
• SHA512—fill in password and privacy keys. The password can be between 8 and 24 characters and use a combination of
alphanumeric and the following special characters <>&@#%_=:;,./?|$*.
• AES / AES192 / AES256
7. If Priv is selected on the communication security mechanism, select the Privacy algorithms.

It is recommended to set AES192/AES256 with the SHA256/SHA384/SHA512 Authentication algorithms.

• AES— fill in password and privacy keys. The password can be between 8 and 24 characters and use a combination of
alphanumeric and the following special characters <>&@#%_=:;,./?|$*.
• AES192—fill in password and privacy keys. The password can be between 8 and 24 characters and use a combination of
alphanumeric and the following special characters <>&@#%_=:;,./?|$*.
• AES256—fill in password and privacy keys. The password can be between 8 and 24 characters and use a combination of
alphanumeric and the following special characters <>&@#%_=:;,./?|$*.
8. Enter your own login password and click Save.

3.7.5.2 Trap receivers

The table shows all the trap receivers and includes the following details:
• Application name
• Host
• Protocol
• Port
• Status: Active/Inactive/Error(configuration error)

Contextual help of the web interface – 127


Settings

3.7.5.2.1 Actions

a Add

1. Press the New button to create new trap receivers.


2. Set following settings:
• Enabled – Yes/No
• Application name
• Hostname or IP address
• Port
• Protocol – V1/V2C/V3
• Trap community (V1/V2C) / User (V3)
3. Press the SAVE button.

b Remove
Select a trap receiver and press the Delete button to remove it.

c Edit

Press the pen icon to edit trap receiver information and access to its settings:

Contextual help of the web interface – 128


Settings

d Test trap
Press the Test trap button to send the trap test to all trap receivers.
Separate window provides the test status with following values:
• In progress
• Request successfully sent
• invalid type

For details on SNMP trap codes, see the Information>>>SNMP traps section.

e MIB Configuration
Press the MIB configuration button to filter the MIBs on which the traps will be applied. This way you may avoid duplicate
information if several MIBs are available on your product.

3.7.5.3 Link to SNMP traps


• UPS Mib
• ATS Mib
• Sensor Mib

3.7.5.4 Default settings and possible parameters - SNMP


Default setting Possible parameters

SNMP Activate SNMP — disabled Activate SNMP — disable/enable


Port — 161 Port — x-xxx
SNMP V1 — disabled SNMP V1 — disable/enable

• Community #1 — public • Community #1 — 128 characters maximum


Enabled — Inactive Enabled — Inactive/Active
Access — Read only Access — Read only
• Community #2 — private • Community #2 — 128 characters
Enabled — Inactive maximum
Access — Read/Write Enabled — Inactive/Active
Access — Read/Write
SNMP V3 — enabled
SNMP V3 — disable/enable
• User #1 — readonly
Enabled — Inactive • User #1 — 32 characters maximum
Access — Read only Enabled — Inactive/Active
Authentication — Auth (SHA-1) Access — Read only/Read-Write
Password — empty Authentication — Auth (SHA-1)/None
Confirm password — empty Password — 128 characters maximum
Privacy — Secured - AES Confirm password — 128 characters
Key — empty maximum
Confirm key — empty Privacy — Secured - AES/None
Key — 128 characters maximum
• User#2 — readwrite
Confirm key — 128 characters maximum
Enabled — Inactive
Access — Read/Write • User#2 — 32 characters maximum
Authentication — Auth (SHA-1) Enabled — Inactive/Active
Password — empty Access — Read only/Read-Write
Confirm password — empty Authentication — Auth (SHA-1)/None
Privacy — Secured - AES Password — 128 characters maximum
Key — empty Confirm password — 128 characters
Confirm key — empty maximum
Privacy — Secured - AES/None
Key — 128 characters maximum
Confirm key — 128 characters maximum

Contextual help of the web interface – 129


Settings

Trap receivers No trap Enabled — No/Yes


Application name — 128 characters maximum
Hostname or IP address — 128 characters maximum
Port — x-xxx
Protocol — V1/V2C/V3
Trap community — 128 characters maximum

3.7.5.4.1 For other settings

For other settings, see the Information>>>Default settings parameters section.

3.7.5.5 Access rights per profiles


Administrator Operator Viewer

SNMP

3.7.5.5.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.7.5.6 Troubleshooting

SNMPv3 password management issue with Save and Restore

Affected FW versions
This issue affects SNMP configuration done on versions prior to 1.7.0 when applied to versions 1.7.0 or above.

Symptom
SNMPv3 connectivity is not properly working after a restore settings on a 1.7.0 version or above.

Cause
The SNMPv3 was configured prior to 1.7.0.
In that case, SNMPv3 configuration is not well managed by the Save and by the Restore settings.

Action
Reconfigure your SNMPv3 users and passwords on versions 1.7.0 or above and Save the settings.
The SNMPv3 configuration can then be Restored.

Contextual help of the web interface – 130


Settings

3.7.5.6.1 For other issues

For details on other issues, see the Troubleshooting section.

3.7.5.7 Save and Restore


SRR section SRR sub section Settings Sub settings Example

SNMP snmp enabled true

port Number: refer to default


settings an possible
parameters for constraints.

v1 enabled true

communities readOnly

Name String: refer to default


settings an possible
parameters for constraints.

Enabled

readWrite

Name String: refer to default


settings an possible
parameters for constraints.

Enabled true/false

v3 enabled true

users name String: refer to default


settings an possible
parameters for constraints.

allowWrite true/false

enabled true/false

auth

enabled true/false

algorithm *

password

plaintext String: refer to default


settings an possible
parameters for constraints.

cyphered -

priv

enabled true/false

Contextual help of the web interface – 131


Settings

algorithm *

password

plaintext String: refer to default


settings an possible
parameters for constraints.

cyphered -

name String: refer to default


settings an possible
parameters for constraints.

allowWrite true/false

enabled true/false

auth

enabled true/false

algorithm *

password

plaintext String: refer to default


settings an possible
parameters for constraints.

cyphered -

priv

enabled true/false

algorithm *

password

plaintext String: refer to default


settings an possible
parameters for constraints.

cyphered -

traps receivers name String: refer to default


settings an possible
parameters for constraints.

host *

port Number: refer to default


settings an possible
parameters for constraints.

community *

protocol 1 : V1
2 : V2C
3 : V3

user *

Contextual help of the web interface – 132


Settings

enabled true/false

3.7.5.7.1 Additional information

For details on Save and Restore, see the Save and Restore section.

3.7.6 Industrial protocols

3.7.6.1 Modbus
This section is only for the Modbus Network Module
For instructions on configuring Modbus see the section Installing the Network Management
Module>>>Configuring Modbus.

3.7.6.1.1 Configuration

a Modbus RTU

For instructions on connecting Modbus RTU see the section Installing the Network Management Module>>>Wiring the RS-485
Modbus RTU terminal>>>Configuring the termination.
The following Modbus RTU settings are configurable:
• Enable

Contextual help of the web interface – 133


Settings

• Baud rate
• Parity
• Stop bits

b Modbus TCP

The following Modbus TCP settings are configurable:


• Enable
• Port

3.7.6.1.2 Mapping configuration

a Mapping configuration table


The table shows all the mapping configuration and includes the following details:
• Custom name
• MAP
• Transport
• Access
• Illegal read
• IP filtering
• Coil/register base address shift

b Actions
Add
Press the New button to create new mapping configuration.
Remove
Select a mapping configuration and press the Delete button to remove it.
Edit

Contextual help of the web interface – 134


Settings

Press the pen logo to edit mapping configuration:

You will get access to the following settings:


• Custom name
• MAP
• Transport
• Device ID & conventional alternative ids you may choose

MAP Conventional IDs

Uid-0 0, 1 , 247, 255

Uid 244 244

Uid 245 245, 253

Uid 140 144

• Illegal read behaviour


• Coil/register base address shift
• IP filtering (add IP addresses separated by a space)
Supported MAPs
Press the Supported MAPs button to download the MAPs.

Contextual help of the web interface – 135


Settings

File is generated in real time and will take into account the Device capabilities and values at the time of the
generation.
Table in the downloaded file will show all possible registers, only the one showing Available equal to True will be
supported by your system.

Mapping file content:


• Address (hex, 0/1-based): register address in hexadecimal
• Address (dec, 0/1 based): register address in decimal
• Type: Register/Discrete
• Size in bytes
• Number of Modbus registers
• Writable: True/False
• Representation: Int16/Uint16/String/Boolean/...
• Name
• Description
• Unit
• Status to 0: status when the register equal 0
• Status to 1: status when the register equal 1
• Available: True/False – Shows if the register is available on current Device
• Value: Shows current value of the register on current Device

3.7.6.2 BACnet
BACnet/IP communication provides read-only data from Building Automation Systems (BASs) so that the Network Module can be
easily integrated in a BAS alongside other BACnet /IP capable devices.

Contextual help of the web interface – 136


Settings

3.7.6.2.1 Configuration

The following BACnet settings are configurable or displayed:


• Enable BACnet IP
• Device Id – Must be unique in BACnet network. Automatically generated from Ethernet MAC address to prevent collisions.
• Device Name – Must be unique in BACnet network. Automatically generated from manufacturer name and serial number to
prevent collisions.
• Device connection control password – Password is required with DCC commands; if it has not been configured, then these
commands will not be authorized.
• Enable Broadcast management device – To register as a Foreign Device with the BACnet BBDM indicated in IP address field.
• BBDM BACnet/IP device – Automatically generated and modifiable, IPv4 address of the BBMD we will register with.
• BBDM Time to live – The BBMD time to live (in seconds), we must "ping" the BBMD we are registered with within this time.

a Actions
Get EPICS file
An electronic protocol implementation conformance statement (EPICS) file provides verification that devices meet BACnet
standards for objects and services.
This allows EPICS files to provide data to software test programs and for system configuration at the BAS.
Press the Get EPICS file button to download the EPICs.

File is generated in real time and will take into account the Device capabilities and values at the time of the
generation.
The file is in text protocol information (.TPI) format and is machine and human readable, open it with any text reader
to view it.

3.7.6.3 Default settings and possible parameters - Industrial protocols


Modbus and BACnet settings are only for the Network Module.

Default setting Possible parameters

Modbus RTU Modbus RTU — Inactive Modbus RTU — Inactive/Active


Baud rate (bps) — 19200 Baud rate (bps) —
1200/2400/4800/9600/19200/38400/57600/115200
Parity — Even
Parity — None/Even/Odd

Contextual help of the web interface – 137


Settings

Stop bits – 1 Stop bits – 1/2

Default setting Possible parameters

Modbus TCP Modbus TCP — Inactive Modbus TCP — Inactive/Active


Port — 502 Port — x-xxx

Default setting Possible parameters

Mapping configuration No mapping Custom name – 128 characters maximum


Map – Eaton ModbusMS compatible, Eaton
PowerXpert UID 0 compatible, Card System
Information
Transport – RTU/TCP
Access – None/Read only/Read/Write
Illegal read behaviour – Return exception/Return
zeros
IP filtering – IP address
Coil/register base address shift – No shift/Shift by 1
(JBUS)

Default setting Possible parameters

BACnet BACnet IP — Inactive BACnet IP — Inactive/Active


Device Id — Automatically generated, must be
unique, 4194304 characters maximum
Device Name — Automatically generated, must be
unique, 1-255 characters maximum, only Latin
letters, numbers, spaces, '_' and '!' symbols
Device connection control password — 6-20
characters maximum
Local port — 1-65535 characters maximum (as all
the other UDP and TCP ports)
MAC address — MAC address format
Broadcast management device — Inactive/Active
BBMD BACnet/IP device — IP address format
BBMD Time to live — 30-1800 seconds

3.7.6.3.1 For other settings

For other settings, see the Information>>>Default settings parameters section.

3.7.6.4 Access rights per profiles


Administrator Operator Viewer

Industrial protocols/Modbus*

Administrator Operator Viewer

Industrial protocols/BACnet*

Contextual help of the web interface – 138


Settings

*for only

3.7.6.4.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.7.6.5 CLI commands

modbus_message_display

This section is only for the Modbus Network Module

Description
modbus_message_display restarts the server and displays Modbus message. This command allow you to verifiy that Modbus
server is working as expected.

Help

modbus_message_display
--help Restart server and display modbus message
-h Restart server and display modbus message

modbus_statistics

This section is only for the Modbus Network Module

Description
modbus_statistics displays Modbus RTU and TCP status and server statistics:
• Bus character overrun count
• Bus frame error count
• Bus parity error count
• Buffer overrun count

• Bus message count


• Valid message count
• CRC error count
• Incoming message count
• Discarded message count
• Processed message count
• Success returned count
• Exception returned count

Contextual help of the web interface – 139


Settings

Help

modbus_statistics
Display modbus server statistics

-h, --help Display the help page.


-r, --reset Reset modbus server statistics.
The counter from A1.1 to A1.4 are reset only at startup of the
server.

3.7.6.5.1 For other CLI commands

See the CLI commands in the Information>>>CLI section.

3.7.6.6 Troubleshooting

Modbus communication doesn't work

Symptoms
• Communication doesn't work

Refer to the section Servicing the Network Management Module>>>Configuring Modbus to get configuration
and testing information.

Possible cause
• Incorrect communication parameters.
Verify that the communication parameters are set to the desired settings.For Modbus TCP configuration refer to the
section Contextual help>>>Settings>>>Modbus>>>Modbus TCP .
For Modbus RTU configuration refer to the section Contextual help>>>Settings>>>Modbus>>>Modbus RTU .
• RS-485 communication lines are reversed
For two-wire networks refer to the section Installing the Network Management Module>>>Wiring the RS-485 Modbus
RTU terminal>>>Two-wire networks .
For four-wire networks refer to the section Installing the Network Management Module>>>Wiring the RS-485 Modbus
RTU terminal>>>Four-wire networks .
• If the Modbus Card is the last device installed in the network chain or the length of the network cable is excessive,
termination needs to be enabled.
Verify the termination settings and refer to the section Installing the Network Management Module>>>Wiring the
RS-485 Modbus RTU terminal>>>Configuring the termination .

3.7.6.6.1 For other issues

For details on other issues, see the Troubleshooting section.

Contextual help of the web interface – 140


Settings

3.7.6.7 Save and Restore


SRR section Settings Sub settings Possible values

Modbus modbus data tcp enabled true/false

port Number: refer to default settings an possible


parameters for constraints.

SRR section Settings Sub settings Possible values

Modbus modbus data rtu enabled true/false

baudrate 1: 1200pbs
2: 2400bps
3: 4800bps
4: 9600bps
5: 19200bps
6: 38400bps
7: 57600bps
8: 115200bps

parity 1: None
2: Even
3: Odd

stopBits 1: 1 Stop bit


2: 2 Stop bits

SRR section Settings Sub settings Possible values

Modbus modbus data mapping configurations name String: refer to default settings an possible
parameters for constraints.

map Eaton ModbusMS compatible, Eaton PowerXpert UID


0 compatible, Card System Information

transport 1: RTU2: TCP

transportFilter *

deviceId Number: refer to default settings an possible


parameters for constraints.

access 0: None
1: Read only
3: Read/Write

illegalReadBehavior 1: Return exception


2: return zeros

addressBaseShift Shift value (1,2,5,..)

name Same as above


map
transport

Contextual help of the web interface – 141


Settings

transportFilter
deviceId
access
illegalReadBehavior
addressBaseShift

Bacnet bacnet configuration access enabled true/false

port Number: refer to default settings an possible


parameters for constraints.

bbmd enabled true/false

ipv4Address xxx.xxx.xxx.xxx

timeToLive number of seconds

servicesEnabled true/false

device deviceId *

deviceName *

dccPassword *

3.7.6.7.1 Additional information

For details on Save and Restore, see the Save and Restore section.

3.7.7 Certificate

3.7.7.1 Pairing with clients


For details on pairing instructions, follow the link pairing instructions in the tile or see the Servicing the Network
Management Module>>>Pairing agent to the Network Module section.

Contextual help of the web interface – 142


Settings

During the selected timeframe, new connections to the Network Module are automatically trusted and accepted.
After automatic acceptance, make sure that all listed clients belong to your infrastructure. If not, access may be revoked using the
Delete button.
The use of this automatic acceptance should be restricted to a secured and trusted network.
For maximum security, we recommend following one of the two methods on the certificate settings page:
• Import agent's certificates manually.
• Generate trusted certificate for both agents and Network Module using your own PKI.

3.7.7.1.1 Actions

a Start
Starts the pairing window during the selected timeframe or until it is stopped.
Time countdown is displayed.

b Stop
Stops the pairing window.

3.7.7.2 Local certificates


Manage local certificates by :
• Generating CSR and import certificates signed by the CA.
• Generating new self-signed certificates.

Contextual help of the web interface – 143


Settings

3.7.7.2.1 Local certificates table

The table shows the following information for each local certificate.
• Used for
• Issued by
• Valid from
• Expiration
• Status — valid, expires soon, or expired

3.7.7.2.2 Actions

a Revoke
This action will take the selected certificate out of use.
Select the certificate to revoke, and then press the Revoke button.
A confirmation window appears, press Continue to proceed, this operation cannot be recovered.

Revoke will replace current certificate by a new self-signed certificate.


This may disconnect connected applications:
- Web browsers
- Shutdown application
- Monitoring application
The certificate that is taken out of use with the revoke action cannot be recovered.

b Export
Exports the selected certificate on your OS browser window.

c Configure issuer
Press the Configure issuer button.
A configuration window appears to edit issuer data.

Contextual help of the web interface – 144


Settings

• Common name (CN)


• Country (C)
• State or Province (ST)
• City or Locality (L)
• Organization name (O)
• Organization unit (OU)
• Contact email address
Press Save button.

Issuer configuration will be applied only after the revoke of the certificate.

d Edit

Press the pen logo:


You will get access to the following:
• Certificate summary
• Actions
• Generate a new self-signed certificate
• Generate a certificate signing request ( CSR )
• Generate a certificate signing request excluding IP addresses ( CA / CB compliance )
• Import certificate (only available when CSR is generated).
• Details

e Generate a new self-signed certificate

To replace a selected certificate with a new self-signed certificate.

Contextual help of the web interface – 145


Settings

This may disconnect applications such as a Web browser, shutdown application, or monitoring application.
This operation cannot be recovered.

f Create new certificates:

g CSR
Press Generate Signing Request button in the in the certificate edition.
The CSR is automatically downloaded.
CSR must be signed with the CA, which is managed outside the card.

h Import certificate
When the CSR is signed by the CA, it can be imported into the Network Module.
When the import is complete, the new local certificate information is displayed in the table.

Regarding the automating renewal:


• In case of expiration, a signed certificate will not renew itself and will be marked invalid / expired.
• In case of network configuration changes (hostname, static IP, etc...), even a signed certificate might be
replaced by a self signed if it becomes invalid

3.7.7.3 Certificate authorities (CA)


Manages CAs.

3.7.7.3.1 CA table

The table displays certificate authorities with the following details:


• Used for
• Issued by
• Issued to
• Valid from
• Expiration
• Status — valid, expires soon, or expired

Contextual help of the web interface – 146


Settings

3.7.7.3.2 Actions

a Import
When importing the CA, you must select the associated service, and then upload process can begin through the OS browser
window.

b Revoke
Select the certificate to revoke, and then press the Revoke button.
A confirmation window appears, press Continue to proceed, this operation cannot be recovered.

Export
Exports the selected certificate on your OS browser window.

c Edit

Press the pen logo to access to the certificate summary:

3.7.7.4 Trusted remote certificates

The table shows the following information for each trusted remote certificate.
• Used for
• Issued by
• Issued to
• Valid from
• Expiration
In case a certificate expires, the connection with the client will be lost. If this happens, the user will have to recreate the
connection and associated certificates.
• Status — valid, expires soon, or expired

3.7.7.4.1 Actions

a Import
When importing the client certificate, you must select the associated service, and then upload process can begin through the OS
browser window.

b Revoke
Select the certificate to revoke, and then press the Revoke button.
A confirmation window appears, press Continue to proceed, this operation cannot be recovered.

Contextual help of the web interface – 147


Settings

c Edit

Press the pen logo to the certificate summary:

3.7.7.5 Default settings and possible parameters - Certificate


Default setting Possible parameters

Local certificates Common name — Service + Hostname + selfsigned Common name — 64 characters maximum
Country — FR Country — Country code
State or Province — 38 State or Province — 64 characters maximum
City or Locality — Grenoble City or Locality — 64 characters maximum
Organization name — Eaton Organization name — 64 characters maximum
Organization unit — Power quality Organization unit — 64 characters maximum
Contact email address — blank Contact email address — 64 characters maximum

3.7.7.5.1 For other settings

For other settings, see the Information>>>Default settings parameters section.

3.7.7.6 Access rights per profiles


Administrator Operator Viewer

Certificate

3.7.7.6.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.7.7.7 CLI commands

certificates

Description
Allows to manage certificates through the CLI.

Help

certificates <target> <action> <service_name>


<target> :
- local
<action> :
- print: provides a given certificate detailed information.

Contextual help of the web interface – 148


Settings

- revoke: revokes a given certificate.


- export: returns a given certificate contents.
- import: upload a given certificate for the server CSR. This will replace the
CSR with the certificate given.
- csr: get the server CSR contents. This will create the CSR if not already
existing.
<service_name>: mqtt/syslog/webserver

Examples of usage

From a linux host:


print over SSH: sshpass -p $PASSWORD ssh $USER@$CARD_ADDRESS certificates local print $SERVICE_NAME
revoke over SSH: sshpass -p $PASSWORD ssh $USER@$CARD_ADDRESS certificates local revoke $SERVICE_NAME
export over SSH: sshpass -p $PASSWORD ssh $USER@$CARD_ADDRESS certificates local export $SERVICE_NAME
import over SSH: cat $FILE | sshpass -p $PASSWORD ssh $USER@$CARD_ADDRESS certificates local import
$SERVICE_NAME
csr over SSH: sshpass -p $PASSWORD ssh $USER@$CARD_ADDRESS certificates local csr mqtt

From a Windows host: (plink tools from putty is required)


print over SSH: plink $USER@$CARD_ADDRESS -pw $PASSWORD -batch certificates local print $SERVICE_NAME
revoke over SSH: plink $USER@$CARD_ADDRESS -pw $PASSWORD -batch certificates local revoke $SERVICE_NAME
export over SSH: plink $USER@$CARD_ADDRESS -pw $PASSWORD -batch certificates local export $SERVICE_NAME
import over SSH: type $FILE | plink $USER@$CARD_ADDRESS -pw $PASSWORD -batch certificates local import
$SERVICE_NAME
csr over SSH: plink $USER@$CARD_ADDRESS -pw $PASSWORD -batch certificates local csr mqtt

Where:
• $USER is user name (the user shall have administrator profile)
• $PASSWORD is the user password
• $PASSPHRASE is any passphrase to encrypt/decrypt sensible data.
• $CARD_ADDRESS is IP or hostname of the card
• $FILE is a certificate file
• $SERVICE_NAME is the name one of the following services : mqtt / syslog / webserver.

3.7.7.7.1 For other CLI commands

See the CLI commands in the Information>>>CLI section.

3.7.7.8 Troubleshooting

Software is not able to communicate with the Network module

Contextual help of the web interface – 149


Settings

Symptoms
• In the Network Module, in Contextual help>>>Protection>>>Agent list>>>Agent list table , agent is showing "Lost" as
a status.
• In the Network Module, in Contextual help>>>Settings>>>Certificate>>>Trusted remote certificates , the status of
the Protected applications (MQTT) is showing "Not valid yet".
• IPP/IPM shows "The authentication has failed", "The notifications reception encountered error".

Possible cause
The IPP/IPM certificate is not yet valid for the Network Module.
Certificates of IPP/IPM and the Network Module are not matching so that authentication and encryption of connections
between the Network Module and the shutdown agents is not working.

Setup
IPP/IPM is started.
Network module is connected to the UPS and to the network.

Action #1
Check if the IPP/IPM certificate validity for the Network Module.
STEP 1: Connect to the Network Module
• On a network computer, launch a supported web browser. The browser window appears.
• In the Address/Location field, enter: https://xxx.xxx.xxx.xxx/ where xxx.xxx.xxx.xxx is the static IP address of the
Network Module.
• The log in screen appears.
• Enter the user name in the User Name field.
• Enter the password in the Password field.
• Click Login. The Network Module web interface appears.
STEP 2: Navigate to Settings/Certificates page
STEP 3: In the Trusted remote certificates section, check the status of the Protected applications (MQTT).
If it is "Valid" go to Action#2 STEP 2, if it is "Not yet valid", time of the need to be synchronized with IPP/IPM .
STEP 4: Synchronize the time of the Network Module with IPP/IPM and check that the status of the Protected applications
(MQTT) is now valid.
Communication will then recover, if not go to Action#2 STEP 2.

Action #2
Pair agent to the Network Module with automatic acceptance (recommended in case the installation is done in a secure and
trusted network).

For manual pairing (maximum security), go to Servicing the Network Management Module>>>Pairing agent
to the Network Module section and then go to STEP 2, item 1.

STEP 1: Connect to the Network Module.


• On a network computer, launch a supported web browser. The browser window appears.
• In the Address/Location field, enter: https://xxx.xxx.xxx.xxx/ where xxx.xxx.xxx.xxx is the static IP address of the
Network Module.
• The log in screen appears.
• Enter the user name in the User Name field.
• Enter the password in the Password field.
• Click Login. The Network Module web interface appears.
STEP 2: Navigate to Protection/Agents list page.

Contextual help of the web interface – 150


Settings

STEP 3: In the Pairing with shutdown agents section, select the time to accept new agents and press the Start button
and Continue. During the selected timeframe, new agent connections to the Network Module are automatically trusted and
accepted.
STEP 4: Action on the agent ( IPP/IPM ) while the time to accepts new agents is running on the Network Module
Remove the Network module certificate file(s) *.0 that is (are) located in the folder
Eaton\IntelligentPowerProtector\configs\tls.

Card wrong timestamp leads to "Full acquisition has failed" error message on Software

Symptoms:
IPP/IPM shows the error message "The full data acquisition has failed" even if the credentials are correct.

Possible cause:
The Network module timestamp is not correct.
Probably the MQTT certificate is not valid at Network module date.

Action:
Set the right date, time and timezone. If possible, use a NTP server, refer to Contextual
help>>>Settings>>>General>>>System details>>>Time & date settings section.

3.7.7.8.1 For other issues

For details on other issues, see the Troubleshooting section.

3.7.7.9 Save and Restore


SRR section Settings Example

Certificate issuer configuration certificateSettings country String: refer to default settings


an possible parameters for
constraints.

state String: refer to default settings


an possible parameters for
constraints.

location String: refer to default settings


an possible parameters for
constraints.

organizationName String: refer to default settings


an possible parameters for
constraints.

organizationUnit String: refer to default settings


an possible parameters for
constraints.

contact String: refer to default settings


an possible parameters for
constraints.

Contextual help of the web interface – 151


Device details

Local certificate (mqtt) mqtt certificateData

ca *

trustedClient *

3.7.7.9.1 Additional information

For details on Save and Restore, see the Save and Restore section.

3.8 Device details

3.8.1 General
On this tab, you can see a list of the device characteristics.

Some UPS may support the download of their system logs. This may prove useful in case the support team needs
it for debugging purposes.
Its content is for Service use only and not intended to be exported into the UI or the PDF

Contextual help of the web interface – 152


Device details

3.8.2 Settings - UPS

This section is only for the UPS device and contains all its settings.

• Audible Alarms - To enable / disable the sound emitted by the UPS when an alarm is triggered ( Battery replacement alarm for
instance or UPS technical fault )
• Battery replacement notification - To enable / disable the battery replacement notification when the battery is getting close to
its estimated end of life
• Output voltage - To select the output voltage that fits best your need

Device unique attributes


Some options proposed may not apply to your device. Please refer to the device User Manual Guide.

3.8.2.1 Specifics

3.8.2.2 Access rights per profiles


Administrator Operator Viewer

UPS

3.8.2.2.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

Contextual help of the web interface – 153


Device details

3.8.3 Settings - ATS

This section is only for the ATS device and contains all its settings.

• Audible alarm - To enable / disable the sound emitted by the UPS when an alarm is triggered ( Battery replacement alarm for
instance or UPS technical fault )
• Prefered source – To set the priority on Source 1 or Source 2 (Source 1 by default).
• Sensitivity – To set the sensitivity mode for input mains detection
• Normal sensitivity by default
• Low sensitivity for compatibility with distorted waveform
• High sensitivity when the load demands higher power stability
• LIA UPS Input when the power source of the ATS is a Line Interactive UPS
• Transfer mode – To set the transfer mode between sources (Standard by default with no additional break even if sources are
no synchronized, Gap with additional break during transfer if sources are not synchronized).
• Nominal voltage – To set voltage thresholds.

Device unique attributes


Some options proposed may not apply to your device. Please refer to the device User Manual Guide.

3.8.3.1 Specifics

3.8.3.2 Access rights per profiles


Administrator Operator Viewer

ATS

3.8.3.2.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

Contextual help of the web interface – 154


Maintenance

3.8.4 Power Modules


This section is only for UPS supporting Uninterruptible Power Modules. Are shown any installed UPM on the
device.

3.8.4.1 Installed Power Modules


• Position - The slot in which the UPS is installed is tagged by a # and a number (e.g #2 )
• Name - The default name of the UPM
• State - Reflects the sate of the UPM ( Ready, Normal, Battery, Alarms, Off, Unknown ... )

3.8.4.2 Details
• Position & Name - Highlight the UPM you chose
• State - Reflect the state of the selected UPM
• Model - The family model of the selected UPM
• Vendor - The vendor of the selected UPM
• Communication - Reflect if the UPM is communicating well with the UPS
• FW Version ( if available ) - The UPM FW version installed on the selected UPM

3.9 Maintenance

3.9.1 Firmware

3.9.1.1 Update Network Card Firmware

• Monitors the information for the two-embedded firmware.


• Upgrade the Network Module firmware.

Contextual help of the web interface – 155


Maintenance

3.9.1.1.1 Card Firmware information

a Status
• Uploading
• Invalid
• Valid
• Pending reboot
• Active

b Version/Sha
Displays the associated firmware version and associated Sha.

c Generated on
Displays the release date of the firmware.
For better performance, security, and optimized features, Eaton recommends to upgrade the Network Module regularly.

d Installation on
Displays when the firmware was installed in the Network Module.

e Activated on
Displays when the firmware was activated in the Network Module.

3.9.1.1.2 Upgrade the Network Module firmware


During the upgrade process, the Network Module does not monitor the Device status.
To upgrade the firmware:
1. Download the latest firmware version from the website. For more information, see the Servicing the Network Management
Module>>>Accessing to the latest Network Module firmware/driver section.
2. Click +Upload.
3. Click Choose file and select the firmware package by navigating to the folder where you saved the downloaded firmware.
4. Click Upload. The upload can take up to 5 minutes.
The firmware that was inactive will be erased by this operation.
When an upgrade is in progress, the upload button is disabled, and the progress elements appear below the table with the
following steps:
Transferring > Verifying package > Flashing > Configuring system > Rebooting

A confirmation message displays when the firmware upload is successful, and the Network Module automatically restarts.

Contextual help of the web interface – 156


Maintenance

Do not close the web browser or interrupt the operation.


Depending on your network configuration, the Network Module may restart with a different IP address.
Refresh the browser after the Network module reboot time to get access to the login page.
Press F5 or CTRL+F5 to empty the browser to get all the new features displayed on the Web user interface.
Communication Lost and Communication recovered may appear in the Contextual help>>>Alarms section.

3.9.1.2 Update Device Firmware

• Upgrade Device Firmware linked to the card.

3.9.1.2.1 Device Firmware information

a Status
• Uploading
• Invalid
• Valid
• Pending reboot
• Active

b Version
Displays the associated firmware version

3.9.1.2.2 Upgrade the Device firmware

During the upgrade process, loads are not protected. Any interruption to input power will result in an interruption of
power to protected loads

To upgrade the device firmware:


1. Download the latest firmware version from the website. For more information, see the Servicing the Network Management
Module>>>Accessing to the latest Network Module firmware/driver section.
2. Click on Upload & Activate button.
3. Select a file and pick the firmware package by navigating to the folder where you saved the downloaded firmware.
4. Click Upload. The upload can take up to 5 minutes.
The firmware that was inactive will be erased by this operation.
When an upgrade is in progress, the upload button is disabled, and the progress elements appear below the table with the
following steps:
Erasing Memory > Programming in progress > Restarting to application mode

A confirmation message displays when the firmware upload is successful.

Contextual help of the web interface – 157


Maintenance

a Upgrade statuses

Status Description

Aborted the upgrade was aborted in some way. It should not happen in normal circumstances

Package Integrity Error the file provided for the firmware does not exist, is not syntactically compliant, has a
wrong signature or a binary block inside has a wrong hash

Invalid Signature package was signed but verification of the signature failed

Device not Ready for Upgrade the device could not be put to upgrade mode

Flashing Error an error has occurred during the flashing

Device Boot Error the device could not be rebooted to normal mode

Incompatible Device the firmware provided is incompatible with the device

Communication Lost communication between the communication module and the device was lost during
the upgrade

3.9.1.3 Access rights per profiles


Administrator Operator Viewer

Firmware

3.9.1.3.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.9.1.4 CLI commands

get release info

Description
Displays certain basic information related to the firmware release.

Help

get_release_info
-d Get current release date
-s Get current release sha1
-t Get current release time
-v Get current release version number

Contextual help of the web interface – 158


Maintenance

3.9.1.4.1 For other CLI commands

See the CLI commands in the Information>>>CLI section.

3.9.1.5 Troubleshooting

The Network Module fails to boot after upgrading the firmware

Possible Cause
1- The IP address has changed.
2- The Network module LED shows solid red after the upgrade.
3- The first boot after the upgrade takes a longer time.
Note: If the application is corrupt, due to an interruption while flashing the firmware for example, the boot will be done on
previous firmware.

Action
1- Recover the IP address and connect to the card.
2- Reset the Network module by using the Restart button on the front panel.
3- Wait until the Network module LED shows flashing green.
Refer to Installing the Network Management Module>>>Accessing the Network Module>>>Finding and setting the IP
address section.

Web user interface is not up to date after a FW upgrade

Symptom
After an upgrade:
• The Web interface is not up to date
• New features of the new FW are not displayed
• An infinite spinner is displayed on a tile

Possible causes
The browser is displaying the Web interface through the cache that contains previous FW data.

Action
Empty the cache of your browser using F5 or CTRL+F5.

3.9.1.5.1 For other issues

For details on other issues, see the Troubleshooting section.

Contextual help of the web interface – 159


Maintenance

3.9.2 Services

3.9.2.1 Service options

3.9.2.1.1 Sanitization
Sanitization removes all the data; the Network Module will come back to factory default settings.

For details on default settings, see the Information>>>Default settings parameters section.

To sanitize the Network Module:


1. Click Sanitize.
A confirmation message displays, click Sanitize to confirm.

Depending on your network configuration, the Network Module may restart with a different IP address.
Only main administrator user will remain with default login and password.
Refresh the browser after the Network module reboot time to get access to the login page.

3.9.2.1.2 Reboot
Reboot means restarting the network module operating system.
To reboot the Network Module:
Click Reboot.
A confirmation message displays, click Reboot to confirm, the reboot time will take approximately less than 2min.

Contextual help of the web interface – 160


Maintenance

Depending on your network configuration, the Network Module may restart with a different IP address.
Refresh the browser after the Network module reboot time to get access to the login page.
Communication Lost and Communication recovered may appear in the Alarm section.

3.9.2.1.3 Settings
Allow to save and restore the Network module settings.

For more details, navigate to Servicing the Network Management Module>>>Saving/Restoring/Duplicating section.

Contextual help of the web interface – 161


Maintenance

3.9.2.1.4 Save

Below settings are not saved:


Local users other than the main administratorSensor settings (commissioning, alarm configuration)

To save the Network module settings:


1. Click on Save
2. Select to include the Network settings if needed.
A passphrase need to be entered twice to cypher the sensitive data.
3. Click on Save

3.9.2.1.5 Restore

Restoring settings may result in the Network module reboot.

To restore the Network module settings:


1. Click on Restore
2. Select to include the Network settings if needed.
3. Enter the passphrase used when the file was saved.
4. Click on Choose file and select the JSON file

Contextual help of the web interface – 162


Maintenance

5. Click on Restore to confirm


6. For safety reason, re-enter your own password to confirm your idendity

3.9.2.1.6 Maintenance
The maintenance report is for the service representative use to diagnose problems with the network module. It is not intended for
the user, which is why the file is protected by a password.
To download the maintenance report file:
Click Download report.
A confirmation message displays, Maintenance report file successfully downloaded.

3.9.2.2 Access rights per profiles


Administrator Operator Viewer

Services

3.9.2.2.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.9.2.3 CLI commands

maintenance

Description
Creates a maintenance report file which may be handed to the technical support.

Contextual help of the web interface – 163


Maintenance

Help

maintenance
<cr> Create maintenance report file.
-h, --help Display help page

Examples of usage
Generate the maintenance report by running the "maintenance" command.
Then retrieve the report from the card using SCP

From a linux host:


sshpass -p $PASSWORD scp $USER@$CARD_ADDRESS:report.zip .

From a Windows host:


pscp -scp -pw $PASSWORD $USER@$CARD_ADDRESS:report.zip report.zip

(Require pscp tools from putty)


Where:
• $USER is user name (the user shall have administrator profile)
• $PASSWORD is the user password
• $CARD_ADDRESS is IP or hostname of the card

reboot

Description
Tool to Reboot the card.

Help

Usage: reboot [OPTION]


<cr> Reboot the card
--help Display help
--withoutconfirmation Reboot the card without confirmation

save_configuration | restore_configuration

Description
Save_configuration and restore_configuration are using JSON format to save and restore certain part of the configuration of
the card.

Contextual help of the web interface – 164


Maintenance

Help

save_configuration -h
save_configuration: print the card configuration in JSON format to standard output.

restore_configuration -h
restore_configuration: restore the card configuration from a JSON-formatted standard
input.

Examples of usage

From a linux host:


Save over SSH: sshpass -p $PASSWORD ssh $USER@$CARD_ADDRESS save_configuration -p $PASSPHRASE> $FILE
Restore over SSH: cat $FILE | sshpass -p $PASSWORD ssh $USER@$CARD_ADDRESS restore_configuration -p
$PASSPHRASE

From a Windows host:


Save over SSH: plink $USER@$CARD_ADDRESS -pw $PASSWORD -batch save_configuration -p $PASSPHRASE > $FILE
Restore over SSH: type $FILE | plink $USER@$CARD_ADDRESS -pw $PASSWORD -batch restore_configuration -p
$PASSPHRASE
(Require plink tools from putty)
Where:
• $USER is user name (the user shall have administrator profile)
• $PASSWORD is the user password
• $PASSPHRASE is any passphrase to encrypt/decrypt sensible data.
• $CARD_ADDRESS is IP or hostname of the card
• $FILE is a path to the JSON file (on your host computer) where the configuration is saved or restored.

sanitize

Description
Sanitize command to return card to factory reset configuration.

Access
• Administrator

Help

sanitize
-h, --help Display help page
--withoutconfirmation Do factory reset of the card without confirmation
<cr> Do factory reset of the card

Contextual help of the web interface – 165


Maintenance

3.9.2.3.1 For other CLI commands

See the CLI commands in the Information>>>CLI section.

3.9.3 Resources
Card resources is an overview of the Network Module processor, memory and storage information.
The COPY TO CLIPBOARD button will copy the information to your clipboard so that it can be past.
For example, you can copy and paste information into an email.

3.9.3.1 Processor

• Used in %
• Up since date

3.9.3.2 Memory

• Total size in MB
• Available size in MB
• Application size in MB

Contextual help of the web interface – 166


Maintenance

• Temporary files size in MB

3.9.3.3 Storage

• Total size in MB
• Available size in MB
• Used size in MB

3.9.3.4 Access rights per profiles


Administrator Operator Viewer

Resources

3.9.3.4.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.9.3.5 CLI commands

systeminfo_statistics

Description
Displays the following system information usage:

1. CPU
a. usage : %
b. upSince : date since the system started
2. Ram
a. total: MB
b. free: MB
c. used: MB
d. tmpfs: temporary files usage (MB)
3. Flash

Contextual help of the web interface – 167


Maintenance

a. user data
i. total: MB
ii. free: MB
iii. used: MB

Help

systeminfo_statistics
Display systeminfo statistics

-h, --help Display the help page.

3.9.3.5.1 For other CLI commands

See the CLI commands in the Information>>>CLI section.

3.9.4 System logs

3.9.4.1 System logs


There are 4 types of logs available:
• Update
• Account
• Session
• System

Select the log files to download and press the download icon:

For the list of system logs, see the Information>>>System Logs codes section.

Contextual help of the web interface – 168


Maintenance

3.9.4.2 Access rights per profiles


Administrator Operator Viewer

System logs

3.9.4.2.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

3.9.5 System information


System information is an overview of the main Network Module information.
The COPY TO CLIPBOARD button will copy the information to the clipboard.

3.9.5.1 Identification
• System name – if filled, it replaces the Device model name in the top bar
• Product
• Physical name
• Vendor
• UUID
• Part number
• Serial number
• Hardware version
• Location
• Contact
• MAC address

3.9.5.2 Firmware information


• Version
• SHA
• Build date
• Installation date
• Activation date
• Bootloader version

3.9.5.3 Access rights per profiles


Administrator Operator Viewer

System information

3.9.5.3.1 For other access rights

For other access rights, see the Information>>>Access rights per profiles section.

Contextual help of the web interface – 169


Alarms

3.10 Alarms

3.10.1 Alarm sorting


Alarms can be sorted by selecting:
• All
• Active only

3.10.2 Active alarm counter


Alarms with a severity set as Good are not taken into account into the counter of active alarms.

3.10.3 Alarm details


All alarms are displayed and sorted by date, with alert level, time, description, and status.

Info/Warning/Critical logo Alarm description text

Active In color In bold with "Active" label

Opened In color

Closed Greyed

Contextual help of the web interface – 170


Alarms

3.10.4 Alarm paging


The number of alarms per page can be changed (10-15-25-50-100).
When the number of alarms is above the number of alarms per page, the buttons First, Previous and Next appears to allow
navigation in the Alarm list.

3.10.5 Export
Press the Export button to download the file.

3.10.6 Clear

Press the Clear button to clear alarms that are older than a specified date and up to a defined severity.

3.10.7 Alarms list with codes


To get access to the Alarm log codes or the System log codes for email subscription, see sections below:

• System log codes


• UPS(HID) alarm log codes
• UPS(XCP and COPI) alarm log codes
• ATS alarm log codes
• EMP alarm log codes
• Network module alarm log codes

3.10.8 Access rights per profiles


Administrator Operator Viewer

Alarm list

Export

Clear

Contextual help of the web interface – 171


User profile

3.10.8.1 For other access rights


For other access rights, see the Information>>>Access rights per profiles section.

3.11 User profile


3.11.1 Access to the user profile

Press the icon on the top right side of the page to access the user profile window:

This page is in read-only mode when connected through LDAP and it displays the preferences applied to all LDAP
users as configured in the Contextual help>>>Settings>>>Remote users>>>LDAP section.

3.11.2 User profile

This page displays the current username with its realm (local, remote) and allows to Change passwords, Edit account and Log out.

Contextual help of the web interface – 172


User profile

3.11.2.1 Account settings

If you have the administrator's rights, you can click on Edit account to edit user profile and update the following information:
Account details
• Full name
• Email
• Phone
• Organization
Preferences
• Language
• Date format
• Time format
• Temperature

Contextual help of the web interface – 173


User profile

3.11.2.2 Change password

Click on Change password to change the password.

In some cases, it is not possible to change the password if it has already been changed within a day period.
Refer to the troubleshooting section.

Contextual help of the web interface – 174


User profile

3.11.2.3 Log out


Click Log out to close the session.

3.11.3 Legal information

This Network Module includes software components that are either licensed under various open source license, or under a
proprietary license.

3.11.4 Component
All the open source components included in the Network Module are listed with their licenses.

3.11.5 Availability of source code


Provides the way to obtain the source code of open source components that are made available by their licensors.

3.11.6 Notice for proprietary elements


Provides notice for our proprietary (i.e. non-Open source) elements.

Contextual help of the web interface – 175


User profile

3.11.7 Default settings and possible parameters - User profile


Default setting Possible parameters

Profile Account details: Account details:

• Full name — Administrator • Full name — 128 characters maximum


• Email — blank • Email — 128 characters maximum
• Phone — blank • Phone — 64 characters maximum
• Organization — blank • Organization — 128 characters maximum
Preferences: Preferences:

• Language — English • Language — English, French, German,


• Date format — MM-DD-YYYY Italian, Japanese, Russian, Simplified
• Time format — hh:mm:ss (24h) Chinese, Spanish, Traditional Chinese
• Temperature — °C (Celsius) • Date format — MM-DD-YYYY / YYY-MM-
DD / DD-MM-YYY / DD.MM.YYY / DD/MM/
YYY / DD MM YYYY
• Time format — hh:mm:ss (24h) / hh:mm:ss
(12h)
• Temperature — °C (Celsius)/°F (Fahrenheit)

3.11.7.1 For other settings


For other settings, see the Information>>>Default settings parameters section.

3.11.8 Access rights per profiles


Administrator Operator Viewer

User profile

Administrator Operator Viewer

Legal information

Contextual help of the web interface – 176


User profile

3.11.8.1 For other access rights


For other access rights, see the Information>>>Access rights per profiles section.

3.11.9 CLI commands


logout

Description
Logout the current user.

Help

logout
<cr> logout the user

whoami

Description
whoami displays current user information:
• Username
• Profile
• Realm

3.11.9.1 For other CLI commands


See the CLI commands in the Information>>>CLI section.

3.11.10 Troubleshooting
Password change in My profile is not working

Symptoms
The password change shows "Invalid credentials" when I try to change my password in My profile menu:

Contextual help of the web interface – 177


User profile

Possible cause
The password has already been changed once within a day period.

Action
Let one day between your last password change and retry.

3.11.10.1 For other issues


For details on other issues, see the Troubleshooting section.

3.11.11 Save and Restore


SRR section Settings Possible values

Account details vCard fullName String: refer to default settings an possible


parameters for constraints.

email String: refer to default settings an possible


parameters for constraints.

phone String: refer to default settings an possible


parameters for constraints.

organization String: refer to default settings an possible


parameters for constraints.

Preferences preferences notifyByMail true/false

licenseAgreed true/false

language de: Deutsch


en: English
es: Español
fr: Français
it: Italiano
ja: 日本語
ru: русский
zh_Hans: 简体中文
zh_Hant:繁體中文

dateFormat Y-m-d: YYYY-MM-DD


d-m-Y: DD-MM-YYYY
d.m.Y: DD.MM.YYYY
d/m/Y: DD/MM/YYYY

Contextual help of the web interface – 178


Documentation

m/d/Y: MM/DD/YYYY
d m Y: DD MM YYYY

timeFormat 1: 24h
0: 12h

temperatureUnit 1: °C
2: °F

3.11.11.1 Additional information


For details on Save and Restore, see the Save and Restore section.

3.12 Documentation
3.12.1 Access to the embedded documentation

Press the ? icon on the top right side of the page to access the documentation in a new window:
The focus will be made on the contextual page.
You can then navigate into below sections:

Installing the Network Management Module How to install and access the Network module.

Contextual help of the web interface Help for each webpage.


Extracts from the sections below when they are related to the web page.

Servicing the Network Management Module How to install and use the Network module.

Securing the Network Management Module How to secure the Network module.

Servicing the EMP Information on the EMP, how to install and use it.

Information General information of the Network Module and Devices.

Troubleshooting How to troubleshoot the Network Module.

Search feature is indexed.

3.12.2 Access rights per profiles


Administrator Operator Viewer

Contextual help of the web interface – 179


Documentation

Contextual help

Full documentation

3.12.2.1 For other access rights


For other access rights, see the Information>>>Access rights per profiles section.

Contextual help of the web interface – 180


Configuring/Commissioning/Testing LDAP

4 Servicing the Network Management Module

4.1 Configuring/Commissioning/Testing LDAP


4.1.1 Commissioning
Refer to the section Contextual help>>>Settings>>>Remote users>>>LDAP to get help on the configuration.

4.1.1.1 Configuring connection to LDAP database


This step configures the LDAP client of the network module to request data from an LDAP base.

1. Activate LDAP.
2. Define security parameters according to LDAP servers' requirements.
3. Configure primary server (and optionally a secondary one).
4. If security configuration needs server certificate verification, import your LDAP server certificate.
Refer to the section to get help on certificate import.
a. In case LDAP server certificate is self-signed, import the self-signed certificate in the Trusted remote certificate list
for LDAP service.
b. in case LDAP server certificate has been signed by a CA, import the corresponding CA in the Certificate authorities
(CA) list for LDAP service.
5. Configure credentials to bind with the LDAP server or select anonymous if no credentials are required.
6. Configure the Search base DN.
7. Configure the request parameters (see examples below).

4.1.1.1.1 Typical request parameters

Parameter OpenLDAP Active Directory™ with POSIX account Active Directory™


activated

User base DN ou=users, dc=example, dc=com ou=users, dc=example, dc=com ou=users, dc=example, dc=com

User name attribute uid uid sAMAccountName

Group base DN ou=groups, dc=example, dc=com ou=groups, dc=example, dc=com ou=groups, dc=example, dc=com

Group name attribute gid gid sAMAccountName

4.1.1.2 Map remote users to profile


This step is mandatory and configures the Network module to give permissions to the LDAP users.
Users not belonging to a group mapped on a profile will be rejected.

Configure the rules to mapped LDAP users to profile:

1. Enter LDAP group name.


2. Select the profile to assigned.
You can define up to 20 mapping rules.
All LDAP users belonging to the configured LDAP group will have permissions granted by the associated profile.

Servicing the Network Management Module – 181


Pairing agent to the Network Module

If a user belongs to multiple LDAP groups mapped to different profiles, the behavior is undefined.

4.1.1.3 Define LDAP user's preferences


This step configures the user's preferences to apply to all LDAP users.

4.1.2 Testing LDAP connection


1. Click on Test icon right to Status column
2. Enter the User credentials then click on Test.
3. This test will verify all the parameters from the connection to the Database to the user credentials.
4. In case of error, the test displays where the issue is located.

4.1.3 Limitations
• If the same username exists in both local and LDAP databases, the behavior is undefined.
• If a user belongs to multiple LDAP groups mapped to different profiles, the behavior is undefined.
• No client certificate provided. It is not possible for the server to verify the client authenticity.
• It is not possible to configure LDAP to work with 2 different search bases.
• LDAP user's preferences are common to all LDAP users.
• LDAP users cannot change their password through the Network Module.
• The remote groupname entered in profile mapping settings must be composed only of alphanumerics, underscore and
hyphen characters (but this last one can't be at the beginning).

4.2 Pairing agent to the Network Module


Authentication and encryption of connections between the UPS network module and shutdown agents is based on matching
certificates.

4.2.1 Pairing with credentials on the agent


STEP 1: Action on the agent (IPP/IPM).
1. Connect to the web interface of the agent.
2. Detect the UPS Network Module with an Address(es) scan, select Override global authentication settings and type the UPS
Network Module credentials.

4.2.2 Pairing with automatic acceptance (recommended if done in a


secure and trusted network)
Pairing with automatic acceptance of shutdown agents and UPS network modules is recommended in case the installation is done
in a secure and trusted network, and when certificates cannot be created in other ways.
STEP 1: Action on the Network Module
1. Connect to the Network Module
• On a network computer, launch a supported web browser. The browser window appears.
• In the Address/Location field, enter: https://xxx.xxx.xxx.xxx where xxx.xxx.xxx.xxx is the static IP address of the Network
Module.
• The log in screen appears.
• Enter the user name in the User Name field.
• Enter the password in the Password field.
• Click Login. The Network Module web interface appears.
2. Navigate to Contextual help>>>Protection>>>Agents list page

Servicing the Network Management Module – 182


Powering down/up applications (examples)

3. In the Pairing with shutdown agents section, select the time to accept new agents and press the Start button and the
press Continue. During the selected timeframe, new agent connections to the Network Module are automatically trusted and
accepted.

STEP 2: Action on the agent (IPP) while the time to accepts new agents is running on the Network Module
1. Connect to the web interface of the agent.
2. Detect the UPS Network Module with a Quick scan, Range scan or an Address(es) scan.
3. Right-click on the UPS Network Module when discovered and then Set as power source, Configure it, and Save it.
STEP 3: Action on the Network Module
1. Make sure all listed agents in the card (Contextual help>>>Protection>>>Agents list) belong to your infrastructure, if not,
access may be revoked using the Delete button.
2. If the time for pairing still runs, you can stop it. Press Stop in the Pairing with shutdown agents section.

STEP 1 and STEP2 can be done either ways.

4.2.3 Pairing with manual acceptance


Manual pairing provides the maximum security.
STEP 1: Action on the agent (IPP)
1. Connect to the web interface of the agent
2. Detect the UPS Network Module with a Quick scan, Range scan or an Address(es) scan.
3. Define the power source
Note: After that stage, the agent creates a client certificate. The power source could show a communication loss since the
current client certificate is not trusted by the Network Module.
4. Copy the agent certificate file client.pem that is located in the folder Eaton\IntelligentPowerProtector\configs\tls..

STEP 2: Action on the Network Module


1. Connect to the Network Module
• On a network computer, launch a supported web browser. The browser window appears.
• In the Address/Location field, enter: https://xxx.xxx.xxx.xxx where xxx.xxx.xxx.xxx is the static IP address of the Network
Module.
• The log in screen appears.
• Enter the user name in the User Name field.
• Enter the password in the Password field.
• Click Login. The Network Module web interface appears.
2. Navigate to Contextual help>>>Settings>>>Certificate page
3. In the Trusted remote certificates section, click Import, select Protected applications (MQTT) and then click on CONTINUE
4. Select the client.pem file previously saved, click Open. Communication with the agent is restored.

4.3 Powering down/up applications (examples)


4.3.1 Powering down IT system in a specific order

4.3.1.1 Target
Powering down applications first (when on battery for 30s), database servers next (3min after the applications), and storage last (as
late as possible).

Servicing the Network Management Module – 183


Powering down/up applications (examples)

4.3.1.2 Step 1: Installation setup

4.3.1.2.1 Objective
Use load segmentation provided by the UPS to independently control the power supply of each IT equipment categories
(Applications, Database servers, Storage).
It also allows IT equipment to sequentially restart on utility recovery (Restart sequentially the IT equipment on utility recovery).

4.3.1.2.2 Resulting setup


UPS provides outlets (Group 1 and Group 2) and a primary output.

When primary shuts OFF, both group 1 and group 2 shut OFF immediately.

Connections to UPS are done as described below:


• Group 1: Applications
• Group 2: Database servers
• Primary: Storage

4.3.1.3 Step 2: Agent settings

4.3.1.3.1 Objective
Ensure IT solution is shutdown gracefully.

4.3.1.3.2 Resulting setup


1. Install IPP Software on each server (Application, Database servers, Storage) and register the UPS load segment as power source:
• Applications: Group 1
• Database servers: Group 2
• Storage: Entire UPS
2. Pair agent to the Network Module (Pairing agent to the Network Module).
When done, each server appears in the Agent list.
3. Navigate to Contextual help>>>Protection>>>Agent shutdown sequencing page.

For examples of Agent settings, see the Agent shutdown sequencing examples section.

Servicing the Network Management Module – 184


Powering down/up applications (examples)

4. Set the OS shutdown duration to the time needed for your server to shutdown gracefully.
This will make sure IPP shutdowns your servers before the load segment is powered down.
As a result, it will define the overall shutdown sequence duration for each load segments.

4.3.1.4 Step 3: Power outage policy settings

4.3.1.4.1 Objective
Use load segment policies to define shutdown sequencing.

4.3.1.4.2 Resulting setup


1. Navigate to Contextual help>>>Protection>>>Shutdown on power outage page of the Network Module

For examples of Power outage policy, see the following sections:


• Maximize availability policy example
• Immediate graceful shutdown policy example
• Load shedding policy examples
• Custom policy examples

2. Make sure Primary is set to: Maximize availability.

Storage is the last one to power down, its availability is maximized, and its shutdown will end 30s before the end of backup
time.
3. Set Group 1 and Group 2 to: Custom.
Applications must shutdown first so Group 1 has been set to start shutdown when on battery for 30s.
Servers must shutdown second, so Group 2 has been set to start shutdown when on battery for 210s, so 3min after the
applications.

Servicing the Network Management Module – 185


Powering down/up applications (examples)

4.3.2 Powering down non-priority equipment first

4.3.2.1 Target
Powering down non-priority equipment first (immediately) and keep battery power for critical equipment.
Powering down critical equipment 3min before the end of backup time.

Servicing the Network Management Module – 186


Powering down/up applications (examples)

4.3.2.2 Step 1: Installation setup

4.3.2.2.1 Objective
Use load segmentation provided by the UPS to independently control the power supply of each IT equipment categories
(Applications, Database servers, Storage).
Load segmentation also allows IT equipment to restart sequentially on utility recovery (Restart sequentially the IT equipment on
utility recovery).

4.3.2.2.2 Resulting setup


UPS provides outlets (Group 1 and Group 2) and a primary output.

When primary shuts OFF, both group 1 and group 2 shut OFF immediately.

Connections can be done as described below:


• Group 2: non-priority equipment
• Group 1: critical equipment
• Primary: critical equipment

4.3.2.3 Step 2: Agent settings

4.3.2.3.1 Objective
Ensure IT solution is shutdown gracefully.

4.3.2.3.2 Resulting setup


1. Install IPP Software on each server (Application, Database servers, Storage) and register the UPS load segment as power source:
• Critical equipment: Group 1
• Non-priority equipment: Group 2
• Critical equipment: Entire UPS
2. Pair agent to the Network Module (Pairing agent to the Network Module).
When done, each server appears in the Agent list.
3. Navigate to Contextual help>>>Protection>>>Agent shutdown sequencing page

For examples of Agent settings, see the Agents shutdown sequencing sections.

Servicing the Network Management Module – 187


Powering down/up applications (examples)

4. Set the OS shutdown duration to the time needed for your server to shutdown gracefully.
This will make sure IPP shutdowns your servers before the load segment is powered down.
As a result, it will define the overall shutdown sequence duration for each load segments.

4.3.2.4 Step 3: Power outage policy settings

4.3.2.4.1 Objective
Use load segment policies to define shutdown sequencing.

4.3.2.4.2 Resulting setup


1. Navigate to Contextual help>>>Protection>>>Shutdown on power outage page on the Network Module

For examples of Power outage policy, see the following sections:


• Maximize availability policy example
• Immediate graceful shutdown policy example
• Load shedding policy examples
• Custom policy examples

2. Set Primary and Group 1 to: Custom and set it to end shutdown sequence 180s before the end of backup time.

Servicing the Network Management Module – 188


Powering down/up applications (examples)

Critical equipment is the last one to power down, their availability will be maximized and their shutdown will end 180s before
the end of backup time.
3. Set Group 2 to: Immediate off.

Non-priority equipment immediately shuts down when on battery for 10s to keep battery power for critical equipment.

4.3.3 Restart sequentially the IT equipment on utility recovery

4.3.3.1 Target
Restart the storage first (right after utility recovery), database servers next (2min after utility recovery) and applications last (3min
after utility recovery).

Servicing the Network Management Module – 189


Powering down/up applications (examples)

4.3.3.2 Step 1: Installation setup

4.3.3.2.1 Objective
Use load segmentation provided by the UPS to independently control the power supply of each IT equipment categories
(Applications, Database servers, Storage).
This will allow to restart sequentially the IT equipment on utility recovery.

4.3.3.2.2 Resulting setup


UPS provides outlets (Group 1 and Group 2) and a primary output.

When utility recovers, primary starts immediately.

Connections to UPS can be done as described below:


• Group 1: Applications
• Group 2: Database servers
• Primary: Storage

4.3.3.3 Step 2: Power outage policy settings

4.3.3.3.1 Objective
Use load segment restart settings to define restart sequencing.

4.3.3.3.2 Resulting setup


1. Navigate to Contextual help>>>Protection>>>Shutdown on power outage page and to the When utility comes back section.

Servicing the Network Management Module – 190


Checking the current firmware version of the Network Module

2. Enable the "Keep shutdown sequence running until the end and then restart (forced reboot)".
3. Enable the "Automatically restart the UPS when battery capacity exceeds" and set it to 0%.
The storage will restart first, right after utility recovery without waiting the battery capacity to exceed a % limit.
4. Set Then Group 1 after to 120s.
The database servers will restart 120s after the utility recovery.
5. Set Then Group 2 after to 60s.
The database servers will restart 180s after the utility recovery.

4.4 Checking the current firmware version of the Network Module


Current firmware of the Network Module can be accessed in :
• The Top bar: Firmware version: x.xx.x
• The Card menu : Contextual help>>>Maintenance>>>System information>>>Firmware information: Version x.xx.x
• The Card menu : Contextual help>>>Maintenance>>>Firmware: Active FW version x.xx.x

4.5 Accessing to the latest Network Module firmware/driver/script


Download the latest Network Module firmware, driver or script from the Eaton website www.eaton.com/downloads

4.6 Upgrading the card firmware (Web interface / shell script)


For instructions on accessing to the latest firmware and script, refer to: Accessing to the latest firmware and script

4.6.1 Web interface


To upgrade the Network module through the Web interface, refer to the section: Firmware upgrade through the Web interface.

4.6.2 Shell script

4.6.2.1 Prerequisite
Shell script uses the following tools: sshpass, scp.
To get it installed on your Linux host, use the following commands.

Servicing the Network Management Module – 191


Upgrading the card firmware (Web interface / shell script)

Debian/Ubuntu

$ sudo apt-get install sshpass scp

RedHat/Fedora/CentOS

$ sudo dnf install sshpass scp

Make shell script executable:

$ chmod 700 install_updatePackage.sh

4.6.2.2 Procedure
To upgrade the Network module using:

1. Open a shell terminal on your computer (Linux or cygwin; meaning real or emulated Linux operating system).
2. Use the shell script install_updatePackage.sh

Usage: 'install_updatePackage.sh' [options]


Upgrade tool
Mandatory arguments are -f, -i, -u and -p
-h : show help
-f <path> : path of the upgrade file
-u <username> : username of a card user allowed to start upgrade
-p <password> : user password
-i <ipaddress> : ip address of the card to upgrade
-r : reboot the card after upgrade

4.6.3 Example:
$ ./install_updatePackage.sh -u admin -p <mypassword> -f FW_Update.tar -i <cardIpAddress> -r

STARTING UPDATE FROM: [FW_Update.tar] to [X.X.X.X]

Transfer by scp (FW_Update.tar) to [X.X.X.X]


Warning: Permanently added 'X.X.X.X' (ECDSA) to the list of known hosts.
Transfer done.
Check running upgrade status ...
Check firmware binary signature
Uncompress and flash upgrade - inProgress(%):11
Uncompress and flash upgrade - inProgress(%):28
Uncompress and flash upgrade - inProgress(%):44
Uncompress and flash upgrade - inProgress(%):61
Uncompress and flash upgrade - inProgress(%):78
Uncompress and flash upgrade - inProgress(%):92
Uncompress and flash upgrade - inProgress(%):100
Uncompress and flash upgrade - inProgress(%):100
Uncompress and flash upgrade
Executing post post_upgrade.sh script upgrade
Upgrade done
Warning: Permanently added 'X.X.X.X' (ECDSA) to the list of known hosts.

Servicing the Network Management Module – 192


Changing the RTC battery cell

Rebooting...
res: Y
Update: OK

4.7 Changing the RTC battery cell


1. Access the Network Module, and then disconnect the Network cable, if needed.
2. Unscrew the Network Module and remove it from the slot.
3. Locate the RTC battery cell located on the back of the Network Module.

4. Get a new battery cell (CR1220 type).

5. Replace the battery cell, the positive mark (+) should be visible when inserting it.

6. Replace the Network Module and secure the screw, reconnect the Network cable if it was unplugged during the operation.
7. Connect the Network Module and set the date and time. For more information, see the Date & Time section.

Servicing the Network Management Module – 193


Updating the time of the Network Module precisely and permanently (ntp server)

4.8 Updating the time of the Network Module precisely and


permanently (ntp server)
For an accurate and quick update of the RTC for the Network Module, we recommend implementing a NTP server as time source
for the Network Module.
LANs have an internal NTP server (Domain Controller, mail servers, Outlook servers are generally time servers too) but you can use
a public ntp server like pool.ntp.org (after addition of the related rules to your firewall system).
For more information, see the Contextual help>>>Settings>>>General>>>System details>>>Time & date settings section.

4.9 Synchronizing the time of the Network Module and the UPS
This section is valid only when the UPS can manage date and time (refer to the UPS user manual for confirmation).

The Network Module use UTC time and manage the time zone and the DST.
The UPS manage only the local time.

4.9.1 Automatic time synchronization

4.9.1.1 Every day at 5 a.m. (UTC time)


The UPS time (local time) is synchronized with the Network Module.

4.9.1.2 If the Network Module time is lost


The Network Module and the UPS time is synchronized with the oldest time between the last know Network Module time and the
UPS time.

4.9.2 Manual time synchronization

4.9.2.1 From the Network Module


On the Network Module, navigate to Contextual help>>>Settings>>>General>>>System details>>>Time & date settings section
and update the time.
The UPS time (local time) is directly synchronized with the Network Module.

4.9.2.2 From the UPS


When the time is updated on the UPS, it is not synchronized on the Network Module.

4.10 Changing the language of the web pages


Update the language of the web page in the Settings menu.

1. Navigate to Contextual help>>>User profile>>>Edit account.


2. Select the language, and then press the Save button.

The language of the login page is English


by default or browser language when it is supported.

Servicing the Network Management Module – 194


Resetting username and password

4.11 Resetting username and password


4.11.1 As an admin for other users
1. Navigate to Contextual help>>>Settings>>>Local users.

2. Press the pen icon to edit user information:


3. Change username and save the changes.
4. Select Reset password and choose from the following options :
• Generate randomly
• Enter manually
• Force password to be changed on next login
5. Enter your own password to confirm the changes.
6. Save the changes.

4.11.2 Resetting its own password


1. Navigate to Contextual help>>>User profile.
2. Press Change password
3. Enter your current password, the new password twice.
4. Press Submit to save the changes.

4.12 Recovering main administrator password


To recover the main administrator password, ask another administrator to initialize the password.
If it is not possible, proceed to the card sanitization:

Below instruction will sanitize the card and blank all the data.
Depending on your network configuration, the Network Module may restart with a different IP address.
Only main administrator user will remain with default login and password.
Refresh the browser after the Network module reboot time to get access to the login page.

1. Access the Network Module, disconnect the Network cable, if needed.


2. Unscrew the Network Module and remove it from the slot.
3. Locate the SANITIZATION switch that is located either on the back or on the Network Module.

Servicing the Network Management Module – 195


Switching to static IP (Manual) / Changing IP address of the Network Module

4. Peel off the protection :

5. Change the position of switch number 3, this change is detected during next power ON and the sanitization will be applied :

Case 1 :

Case 2 :

Changes of the switches 1, 2 or 4 has no effect.

6. Replace the Network Module and secure the screw, connect the Network cable, if needed.
7. Connect the Network Module by using the default credentials of the main administrator : admin/admin.
8. You will be forced to change the password accordingly to the current password strength rules.

4.13 Switching to static IP (Manual) / Changing IP address of the


Network Module
Administrators can switch to static IP in the Settings menu and change the IP address of the Network Module.

1. Navigate to Contextual help>>>Settings>>>Network & Protocol>>>IPV4.


2. Select Manual (Static IP).
3. Input the following information:
• IPv4 Address
• Subnet Mask
• Default Gateway

Servicing the Network Management Module – 196


Reading device information in a simple way

4. Save the changes.

4.14 Reading device information in a simple way


4.14.1 Web page
The product information is located in the , specifically with the button on the top of the diagram:

4.15 Subscribing to a set of alarms for email notification


4.15.1 Example #1: subscribing only to one alarm (load unprotected)
Follow the steps below:
1. Navigate to Contextual help>>>Settings>>>General>>>Email notification settings.
2. Press the button New to create a new configuration.
3. Select:
• Active: Yes
• Configuration name: Load unprotected notification
• Email address: [email protected]
• Notify on events: Active
• Always notify events with code: 81E (Load unprotected)

Servicing the Network Management Module – 197


Subscribing to a set of alarms for email notification

Logs will be attached by default in that example even if there is no subscription on card or device events.

4. Press Save, the table will show the new configuration.

4.15.2 Example #2: subscribing to all Critical alarms and some specific
Warnings
Follow the steps below:
1. Navigate to Contextual help>>>Settings>>>General>>>Email notification settings.
2. Press the button New to create a new configuration.
3. Select:
• Active: Yes
• Configuration name: ALL Critical and User account Warning notification
• Email address: [email protected]
• Notify on events: Active
• Subscribe to Critical card events and Critical device events
• Always notify events with code: 0800700, 0800900 (User account - password expired, User account- locked)

Servicing the Network Management Module – 198


Saving/Restoring/Duplicating Network module configuration settings

4. Press Save, the table will show the new configuration.

4.16 Saving/Restoring/Duplicating Network module configuration


settings
4.16.1 Modifying the JSON configuration settings file

4.16.1.1 JSON file structure


The JSON file is structured into 3 blocks:

Servicing the Network Management Module – 199


Saving/Restoring/Duplicating Network module configuration settings

4.16.1.1.1 File block


File block cannot be modified, this is the mandatory structure of the JSON file.

4.16.1.1.2 Feature block


Feature block contains the full definition of a feature.
If it is removed from the JSON file, this feature settings will not be updated/restored in the card.

4.16.1.1.3 Data block


Data block contains all the feature settings values.

Servicing the Network Management Module – 200


Saving/Restoring/Duplicating Network module configuration settings

a Data block
Data block cannot be modified, this is the mandatory structure of the JSON file.

b Value block
If some values inside the Value block need to be kept, Value block structure cannot be modified, this is the mandatory structure of
the JSON file.
If it is removed from the JSON file, these values will not be updated/restored.

c Values
Values can be kept as is, modified or removed.
Removed values will not be updated/restored.

4.16.1.2 Sensitive data (like passwords)


JSON file structure will slightly varies if sensitive data are exported with passphrase or not.

4.16.1.2.1 The JSON file is saved using passphrase (preferred)


All sensitive data will have below structure:

When restoring the file, the corresponding setting will be updated based on the cyphered value.

4.16.1.2.2 The JSON file is saved without passphrase


All sensitive data will have below structure:

Servicing the Network Management Module – 201


Saving/Restoring/Duplicating Network module configuration settings

When restoring the file, the corresponding setting will not be set.
This may lead to restoration failure if corresponding setting was not previously set with a valid value.

4.16.1.3 Modifying JSON file examples

4.16.1.3.1 Modifying sensitive data


To change sensitive data, plain text must be filled with the new value and the Cyphered entry (if existing) must be removed:

4.16.1.3.2 Adding local users


Adding or modifying local users is not yet available, only the predefined account (main administrator) can be modified.

4.16.1.3.3 Modifying SNMP settings

Original file: Modified file:

SNMP disabled SNMP enabled on port 161


SNMPv1 disabled
SNMPv3 enabled
2 x accounts
1 x read only user (enabled) with Auth-Priv security level and passwords
1x read write user (enabled) with Auth-Priv security level and passwords
1 x active trap

Servicing the Network Management Module – 202


Saving/Restoring/Duplicating Network module configuration settings

Original file: Modified file:

4.16.1.3.4 Making a partial update/restoration

a Example: Updating/Restoring only LDAP settings


If you restore below JSON content, only LDAP settings will be updated/restored, everything else will remain unchanged.

{
"version": "x.x",
"features": {

Servicing the Network Management Module – 203


Saving/Restoring/Duplicating Network module configuration settings

"ldap": {
"data": {
"version": "x.x",
"certificateData": [],
"dmeData": {
"enabled": true,
"baseAccess": {
"security": {"ssl": 1,"verifyTlsCert": false},
"primary": {"name": "Primary","hostname": "xxxxxxxxx","port": xxxx},
"secondary": {"name": "xxxxxx","hostname": "xxxxxx","port": xxxx},
"credentials": {
"anonymousSearchBind": false,
"searchUserDN":
"CN=xxxx,OU=xxxx,OU=xxxx,OU=xxxx,DC=xxxx,DC=xxxx",
"password": {"plaintext": null}},
"searchBase": {"searchBaseDN": "DC=xxx,DC=xxx,DC=xxx"}
},
"requestParameters": {
"userBaseDN": "OU=xxxx,DC=xxxx",
"userNameAttribute": "xxxx",
"uidAttribute":"objectSid:x-x-x-xx-xxxxxxxxxx-xxxxxxxxxx-xxxxxxxxxx",
"groupBaseDN": "OU=xxxx,DC=xxxx",
"groupNameAttribute": "xx",
"gidAttribute":"objectSid:x-x-x-xx-xxxxxxxxxx-xxxxxxxxxx-xxxxxxxxxx"
},
"profileMapping": [
{ "remoteGroup": "xxxxxxxxxxxxxx","profile": 1},
{ "remoteGroup": "xxxxxxxxxxxxxx","profile": 2},
{ "remoteGroup": "","profile": 0},
{ "remoteGroup": "","profile": 0},
{ "remoteGroup": "","profile": 0}
]
}
}
},
},
"firmwareVersion": "x.x.x"
}

4.16.2 Saving/Restoring/Duplicating settings through the CLI


Navigate to Information>>>CLI>>>save_configuration | restore_configuration section to get example on how to save and restore
settings through the CLI.

4.16.3 Saving/Restoring/Duplicating settings through the Web interface


Navigate to Contextual help>>>Maintenance>>>Services section to get information on how to save and restore settings through
the Web interface.

Servicing the Network Management Module – 204


Cybersecurity considerations for electrical distribution systems

5 Securing the Network Management Module

5.1 Cybersecurity considerations for electrical distribution systems


5.1.1 Purpose
The purpose of this section is to provide high-level guidance to help customers across industries and applications apply Eaton
solutions for power management of electrical systems in accordance with current cybersecurity standards.
This document is intended to provide an overview of key security features and practices to consider in order to meet industry
recommended standards and best practices.

5.1.2 Introduction
Every day, cyber-attacks against government and commercial computer networks number in the millions. According to U.S. Cyber
Command, Pentagon systems are probed 250,000 times per hour. Similar attacks are becoming more prevalent on other kinds of
information-based smart networks as well, such as those that operate buildings and utility systems. Whether the objective is to
steal intellectual property or halt operations, the tools and the techniques used for unauthorized network access are increasingly
sophisticated.

5.1.3 Connectivity—why do we need to address cybersecurity for


industrial control systems (ICS)?
There is increasing concern regarding cybersecurity across industries where companies are steadily integrating field devices into
enterprise-wide information systems. This occurs in discrete manufacturing and process industrial environments, a wide range of
general and specific purpose commercial buildings, and even utility networks. Traditionally, electrical systems were controlled
through serial devices connected to computers via dedicated transceivers with proprietary protocols. In contrast, today’s control
systems are increasingly connected to larger enterprise networks, which can expose these systems to similar vulnerabilities that
are typically found in computer systems. The differences between information technology (IT) and ICS networks can be
summarized as follows:
• The main focus of the IT network is to ensure the confidentiality and the integrity of the data using rigorous access control
and data encryption
• The main focus of the ICS network is safety, availability, and integrity of data
• Enterprise security protects the servers’ data from attack
• Control system security protects the facility’s ability to safely and securely operate, regardless of what may befall the rest of
the network

5.1.4 Cybersecurity threat vectors


Cybersecurity threat vectors are paths or tools that an entity can use to gain access to a device or a control network in order to
deliver a malicious attack. Figure below shows examples of attack vectors on a network that might otherwise seem secure.

Securing the Network Management Module – 205


Cybersecurity considerations for electrical distribution systems

5.1.4.1 Paths to the control network

The paths in above figure include:


• External users accessing the network through the Internet
• Misconfigured firewalls
• Unsecure wireless routers and wired modems
• Infected laptops located elsewhere that can access the network behind the firewall
• Infected USB keys and PLC logic programs
• Unsecure RS-232 serial links
The most common malicious attacks come in the following forms:
• Virus—a software program that spreads from one device to another, affecting operation
• Trojan horse—a malicious device program that hides inside other programs and provides access to that device
• Worm—a device program that spreads without user interaction and affects the stability and performance of the ICS network
• Spyware—a device program that changes the configuration of a device

5.1.5 Defense in depth


While there are differences between traditional IT systems and ICS, the fundamental concept of “defense in depth” is applicable to
both. Defense in depth is a strategy of integrating technology, people, and operations capabilities to establish variable barriers
across multiple layers of an organization. These barriers include electronic countermeasures such as firewalls, intrusion detection
software/components, and antivirus software, coupled with physical protection policies and training. Fundamentally, the barriers are
intended to reduce the probability of attacks on the network and provide mechanisms to detect “intruders.”

Securing the Network Management Module – 206


Cybersecurity considerations for electrical distribution systems

5.1.6 Designing for the threat vectors

5.1.6.1 Firewalls
Firewalls provide the capability to add stringent and multifaceted rules for communication between various network segments and
zones in an ICS network. They can be configured to block data from certain segments, while allowing the relevant and necessary
data through. A thorough understanding of the devices, applications, and services that are in a network will guide the appropriate
deployment and configuration of firewalls in a network. Typical types of firewalls that can be deployed in a network include:
• Packet filter or boundary firewalls that work on the network layer
These firewalls mainly operate at the network layer, using pre-established rules based on port numbers and protocols to
analyze the packets going into or out of a separated network.
These firewalls either permit or deny passage based on these rules.
• Host firewalls
These firewalls are software firewall solutions that protect ports and services on devices. Host firewalls can apply rules that
track, allow, or deny incoming and outgoing traffic on the device and are mainly found on mobile devices, laptops, and
desktops that can be easily connected to an ICS.

• Application-level proxy firewalls


These firewalls are highly secure firewall protection methods that hide and protect individual devices and computers in a
control network. These firewalls communicate at the application layer and can provide better inspection capabilities. Because
they collect extensive log data, application-level proxy firewalls can negatively impact the performance of an ICS network.
• Stateful inspection firewalls
These firewalls work at the network, session, and application layers of the open system interconnection (OSI). Stateful
inspection firewalls are more secure than packet filter firewalls because they only allow packets belonging to allowed
sessions.
These firewalls can authenticate users when a session is established and analyze a packet to determine whether they contain
the expected payload type or enforce constraints at the application layer.
• SCADA hardware firewalls
These are hardware-based firewalls that provide defense for an ICS based on observing abnormal behavior on a device within
the control network. For example, if an operator station computer suddenly attempts to program a PLC, this activity could be
blocked and an alarm could be raised to prevent serious risk to the system.

5.1.6.2 Demilitarized zones (DMZ)


Network segmentation is a key consideration in establishing secure control networks. Firewalls should be used to create DMZ by
grouping critical components and isolating them from the traditional business IT network. A three-tier architecture should be
employed at a minimum, with a DMZ between the organization’s core network and an isolated control system’s network as shown
in below figure.

Securing the Network Management Module – 207


Cybersecurity considerations for electrical distribution systems

5.1.6.2.1 Three-tier architecture for a secure control network

Above figure shows that the control networks are divided into layers or zones based on control functions, which are then
connected by conduits (connections between the zones) that provide security controls to:
• Control access to zones
• Resist denial of services (DOS) attacks or the transfer of malware
• Shield other network systems
• Protect the integrity and the confidentiality of network traffic
Beyond network segmentation, access control (both physical and logical) should be defined and implemented.
The key consideration when designing access control is defining the required interactions both within a given zone and between
zones. These interactions should be mapped out clearly and prioritized based on need. It is important to realize that every hole
poked in a firewall and each non-essential functionality that provides access or creates additional connectivity increases potential
exposure to attacks. A system then becomes only as secure as the devices connecting to it.
If mapped correctly, the potential adverse impact to control system reliability and functionality should be negligible. However, this
element introduces additional costs (in terms of firewall and other network infrastructure) and complexity to the environment.

Securing the Network Management Module – 208


Cybersecurity considerations for electrical distribution systems

5.1.6.3 Intrusion detection and prevention systems (IDPS)


These are systems that are primarily focused on identifying possible incidents in an ICS network, logging the information about
them, attempting to stop them, and reporting them to ICS security administrators.
Because these systems are critical in an ICS network, they are regular targets for attacks and securing them is extremely important.
The type of IDPS technology deployed will vary with the type of events that need to be monitored.
There are four classes of IDPS technology:
• Network-based IDPS monitors network traffic for particular ICS network segments or devices and analyzes the network and
application protocol activity to identify suspicious activity
• Wireless IDPS monitors and analyzes wireless network traffic to identify suspicious activity involving the ICS wireless
network protocol
• Network behavior analysis IDPS examines ICS network traffic to identify threats that generate unusual traffic flows such as
DOS attacks
• Host-based IDPS monitors the characteristics and the events occurring within a single ICS network host for suspicious
activity

5.1.7 Policies, procedures, standards, and guidelines


For the defense in depth strategy to succeed, there must be well-documented and continuously reviewed policies, procedures,
standards, and guidelines.
• Policies provide procedures or actions that must be carried out to meet objectives and to address the who, what, and why
• Procedures provide detailed steps to follow for operations and to address the how, where, and when
• Standards typically refer to specific hardware and software, and specify uniform use and implementation of specific
technologies or parameters
• Guidelines provide recommendations on a method to implement the policies, procedures, and standards

5.1.7.1 Understanding an ICS network


Creating an inventory of all the devices, applications, and services that are hosted in a network can establish an initial baseline for
what to monitor. Once those components are identified and understood, control, ownership, and operational consideration can be
developed.

5.1.7.2 Log and event management


It is important to understand what is happening within the network from both a performance and security perspective. This is
especially true in a control systems environment.
Log and event management entails monitoring infrastructure components such as routers, firewalls, and IDS/IPS, as well as
host assets. Security Information and Event Management (SIEM) systems can collect events from various sources and provide
correlation and alerts.
Generating and collecting events, or even implementing a SIEM is not sufficient by itself. Many organizations have SIEM solutions,
but alerts go unwatched or unnoticed.
Monitoring includes both the capability to monitor environments and the capacity to perform the monitoring. Capability relates to
the
design and the architecture of the environment. Has it been built in a manner that takes into consideration the ability to monitor?
Capacity speaks to the resources (personnel, tools, expertise) needed to perform meaningful interpretation of the information and
initiate timely and appropriate action.
Through monitoring, the organization can identify issues such as suspicious or malicious activities. Awareness can be raised when
new (potentially unauthorized) devices appear in the environment. Careful consideration should be taken into account to ensure that
log and event management does not adversely impact the functionality or the reliability of the control system devices.

5.1.7.3 Security policy and procedures


It is important to identify “asset owners,” and to develop policies and procedures for a cybersecurity program. These policies need
to be practical and enforceable in order to be effective. Policies should also address access related issues, such as physical access,
contractors, and vendors.

Securing the Network Management Module – 209


Cybersecurity considerations for electrical distribution systems

Existing (traditional) IT standards and policies may not apply (or have not been considered) for control systems. A gap analysis
should be performed to determine which components are not covered (or not adequately covered) by existing policies.
Relationships with existing policies and standards should be explicitly identified and new or supporting policies should be
developed. It is important that industrial control system administrators have proper authorizations and full support of their
management to implement policies that will help secure the ICS network.

5.1.7.4 ICS hardening


The goal for system hardening is to reduce as many security risks as possible by securely configuring ICS networks. The idea is to
establish configurations based on what is required and eliminate unnecessary services and applications that could potentially
provide another possible entry point to an intruder.
Minimum security baselines should be established for the various platforms and products deployed (operating system, application,
and infrastructure elements such as drives, meters, HMI devices). The following actions should be implemented where applicable:
• Disable unnecessary services
• Disable anonymous FTP
• Do not use clear text protocols (e.g., use SSH v2 instead of Telnet)
• Install only required packages/applications/features
• Deploy antivirus solutions (where possible)
• Disable or otherwise control use of USB devices
• Establish a warning banner
• Change default passwords (e.g., SNMP)
It may be easier to implement these actions on devices for which you control the base operating system platform. However,
several
of the items listed above can be configured from the product specific configuration options.
Changes such as these could potentially impact the functionality of a control system device. Extensive testing needs to be
conducted before deployment to minimize this impact.

5.1.7.5 Continuous assessment and security training


It is critical that ICS network administrators and regular users be properly trained to ensure the security of the ICS and the safety of
the people who operate and depend on it.
Ongoing vulnerability assessments are critical to identify issues and understand the effectiveness of other defensible network
elements.
Assessments should include testing and validating the following:
• Monitoring capabilities and alerts are triggered and responded to as expected
• Device configuration of services and applications
• Expected connectivity within and between zones
• Existence of previously unknown vulnerabilities in the environment
• Effectiveness of patching
A program should be established for performing assessments.
The actual assessment should be performed by a qualified resource, which can be an in-house or third-party organization.
Regardless of who performs the assessments, in-house resources need to be involved in the planning, scoping, and supporting of
assessment activities and must be appropriately trained to do so.
Assessments should be conducted according to a methodology that is clearly defined to address:
• Physical security
• People and processes
• Network security
• Host security
• Applications security (both internally developed and commercially off-the-shelf (COTS))

5.1.7.6 Patch management planning and procedures


A patching and vulnerability management process should be established based on the timely awareness of issues and appropriate
action. This process should take all of the elements that make up the control system environment into consideration.
Information resources should be identified for vulnerability and advisory information for the various components in the environment.
These should include vendor-specific sources as well as other public or commercial services that provide vulnerability advisory
information. For example, the National Vulnerability Database (NVD) provides information related to vulnerabilities identified in

Securing the Network Management Module – 210


Cybersecurity considerations for electrical distribution systems

general IT components, while the Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) publishes advisories
specific to control systems.
A regular patch deployment schedule should be established for each component in the environment. Depending on the component,
this could range from a monthly schedule to an as-needed deployment, depending on the historical frequency of patch or
vulnerability related issues for the component or the vendor. Additionally, out-of-band or emergency patch management needs to
be
considered and qualifications need to be defined.
Vulnerability information and advisories should be reviewed regularly and assessments should be performed to determine the
relative severity and urgency of issues.
Elements of the process should also include the preparation, scheduling, and change controls; testing and rollback procedures;
and pre-deployment notification to stakeholders that includes scope, expectations, and reporting. Testing is a significant element,
as
the effect of the patch application needs to be clearly understood; unintended or unexpected impacts to a control system
component influence the decision to deploy a patch. In the event that it is determined that a patch cannot be safely deployed but
the severity of the issue represents a significant concern, compensating controls should be investigated.

5.1.8 Conclusion
To protect important assets, all organizations must take cybersecurity threats seriously and meet them proactively with a system-
wide defensive approach specific to organizational needs.
There is no protection method that is completely secure. A defense mechanism that is effective today may not be effective
tomorrow– the ways and means of cyber-attacks constantly change. It is critical ICS administrators remain aware of changes in
cybersecurity and continue to work to prevent any potential vulnerabilities in the systems they manage.

5.1.9 Terms and definitions


DMZ A demilitarized zone is a logical or physical sub network that interfaces an organization’s external
services to a larger, untrusted network and providing an additional layer of security.

Encryption The process of transforming plain or clear text using an algorithm to make it unreadable to anyone
except those possessing special knowledge.

ICS A device or set of device that manage, command, direct, or regulate the behavior of other devices
or systems.

Protocol A set of standard rules for data representation, signaling, authentication, and error detection
required to send information over a communications channel

5.1.10 Acronyms
COTS Commercially Off-the-Shelf

DMZ Demilitarized Zone

DOS Denial of Service

FTP File Transfer Protocol

HMI Human Machine Interface

ICS Industrial Control Systems

ICS-CERT Industrial Control Systems - Cyber Emergency Response Team

IDPS Intrusion Detection and Prevention Systems

IDS Intrusion Detection Systems

Securing the Network Management Module – 211


Cybersecurity considerations for electrical distribution systems

IPS Intrusion Prevention Systems

IT Information Technology

NVD National Vulnerability Database

OSI Open System Interconnection

PLC Programmable Logic Controller

SCADA Supervisory Control and Data Acquisition

SNMP Simple Network Management Protocol

SSH Secure Shell

SIEM Security Information and Event Management

USB Universal Serial Bus

5.1.11 References
[1] Recommended Practice: Improving Industrial Control Systems Cybersecurity with Defense-In-Depth Strategies, October 2009
https://ics-cert.us-cert.gov/sites/default/files/FactSheets/NCCIC%20ICS_FactSheet_Defense_in_Depth_Strategies_S508C.pdf
[2] NIST.SP.800-82 Guide to Industrial Control Systems (ICS) Security, June 2011
http://csrc.nist.gov/publications/nistpubs/800-82/SP800-82-final.pdf
[3] NIST.SP.800-94 Guide to Intrusion Detection and Prevention Systems (IDPS), Feb 2007
http://csrc.nist.gov/publications/nistpubs/800-94/SP800-94.pdf
[4] Common Cybersecurity Vulnerabilities in Industrial Control Systems, May 2011
http://ics-cert.uscert.gov/sites/default/files/recommended_practices/DHS_Common_Cybersecurity_Vulnerabilities_ICS_2010.pdf
[5] The Tao of Network Security Monitoring, 2005 Richard Bejtlich

Securing the Network Management Module – 212


Cybersecurity recommended secure hardening guidelines

5.2 Cybersecurity recommended secure hardening guidelines


• Introduction
• Secure configuration guidelines
• Asset Management
• Defense in Depth
• Risk Assessment
• Physical Security
• Account management
• Time Synchronization
• Deactivate unused features
• Network Security
• Remote access
• Logging and Event Management
• Malware defenses
• Secure Maintenance
• Business Continuity / Cybersecurity Disaster Recovery
• Sensitive Information Disclosure
• Decommissioning or Zeroization
• References

5.2.1 Introduction
This Network module has been designed with cybersecurity as an important consideration. Number of features are offered in the
product to address cybersecurity risks. These Cybersecurity Recommendations provide information to help users to deploy and
maintain the product in a manner that minimizes the cybersecurity risks. These Cybersecurity Recommendations are not intended
to provide a comprehensive guide to cybersecurity, but rather to complement customers’ existing cybersecurity programs.
Eaton is committed to minimizing the cybersecurity risk in its products and deploying cybersecurity best practices in its products
and solutions, making them more secure, reliable and competitive for customers.
The following whitepapers are available for more information on general cybersecurity best practices and guidelines:
Cybersecurity Considerations for Electrical Distribution Systems (WP152002EN): http://www.eaton.com/ecm/groups/public/@pub/
@eaton/@corp/documents/content/pct_1603172.pdf
Cybersecurity Best Practices Checklist Reminder (WP910003EN): http://www.cooperindustries.com/content/dam/public/
powersystems/resources/library/1100_EAS/WP910003EN.pdf
Cybersecurity Best Practices for Modern Vehicles - NHTSA: https://www.nhtsa.gov/staticfiles/nvs/pdf/
812333_CybersecurityForModernVehicles.pdf

5.2.2 Secure configuration guidelines

5.2.2.1 Asset Management


Keeping track of software and hardware assets in your environment is a pre-requisite for effectively managing cybersecurity. Eaton
recommends that you maintain an asset inventory that uniquely identifies each important component.
To facilitate this, Network module supports the following identifying information:

5.2.2.1.1 Network Module identification and its firmware information


It can be retrieved by navigating to Card>>>System information or Maintenance>>>System information.
Identification
• System name
• Product
• Physical name
• Vendor
• UUID
• Part number

Securing the Network Management Module – 213


Cybersecurity recommended secure hardening guidelines

• Serial number
• Hardware version
• Location
• Contact
Firmware information
• Firmware version
• Firmware SHA
• Firmware date
• Firmware installation date
• Firmware activation date
• Bootloader version

5.2.2.1.2 Communication settings


It can be retrieved by navigating to Settings>>>Network or Settings>>>Network & Protocol
LAN
• Link status
• MAC address
• Configuration
IPV4
• Status
• Mode
• Address
• Netmask
• Gateway
Domain
• Mode
• FQDN
• Primary DNS
• Secondary DNS
IPV6
• Status
• Mode
• Addresses

5.2.2.1.3 UPS details


It can be retrieved by navigating to Home>>>Details or Home>>>Energy flow .
Details
• Name
• Model
• P/N
• S/N
• Location
• FW version

Most of above information are discoverable using SNMP, refer to Settings>>>SNMP.

5.2.2.2 Defense in Depth


Defense in Depth basically means applying multiple counter-measures for mitigating risks, in a layered or step wise manner. A
layered approach to security as shown in the below diagram is what is recommended. Defense in Depth is the responsibility of
both the manufacturer and the customer.

Securing the Network Management Module – 214


Cybersecurity recommended secure hardening guidelines

5.2.2.3 Risk Assessment


Eaton recommends conducting a risk assessment to identify and assess reasonably foreseeable internal and external risks to the
confidentiality, availability and integrity of the system | device and its environment. This exercise should be conducted in
accordance with applicable technical and regulatory frameworks such as IEC 62443 and NERC-CIP. The risk assessment should be
repeated periodically.

5.2.2.4 Physical Security


An attacker with unauthorized physical access can cause serious disruption to system/device functionality. Additionally, Industrial
Control Protocols don’t offer cryptographic protections, making ICS and SCADA communications especially vulnerable to threats to
their confidentiality. Physical security is an important layer of defense in such cases. The Network module is designed to be
deployed and operated in a physically secure location. Following are some best practices that Eaton recommends to physically
secure your system/device:
• Secure the facility and equipment rooms or closets with access control mechanisms such as locks, entry card readers,
guards, man traps, CCTV, etc. as appropriate.
• Restrict physical access to cabinets and/or enclosures containing the Network module and the associated system. Monitor
and log the access at all times.
• Physical access to the telecommunication lines and network cabling should be restricted to protect against attempts to
intercept or sabotage communications. It’s a best practice to use metal conduits for the network cabling running between
equipment cabinets.
• The Network module supports the following physical access ports: RJ45, USB A, USB Micro-B. Access to these ports should
be restricted.
• Do not connect removable media (e.g., USB devices, SD cards, etc.) for any operation (e.g., firmware upgrade, configuration
change, or boot application change) unless the origin of the media is known and trusted.
• Before connecting any portable device through a USB port or SD card slot, scan the device for malware and viruses.

5.2.2.5 Account management


Logical access to the system | device should be restricted to legitimate users, who should be assigned only the privileges
necessary to complete their job roles/functions. Some of the following best practices may need to be implemented by
incorporating them into the organization’s written policies:
• Ensure default credentials are changed upon first login Network module should not be deployed in production environments
with default credentials, as default credentials are publicly known.
• No account sharing – Each user should be provisioned a unique account instead of sharing accounts and passwords. Security
monitoring/logging features in the product are designed based on each user having a unique account. Allowing users to
share credentials weakens security.
• Restrict administrative privileges - Attackers seek to gain control of legitimate credentials, especially those for highly
privileged accounts. Administrative privileges should be assigned only to accounts specifically designated for administrative
duties and not for regular use.
• Leverage the roles / access privileges admin, operator, viewer to provide tiered access to the users as per the business /
operational need. Follow the principle of least privilege (allocate the minimum authority level and access to system resources
required for the role).

Securing the Network Management Module – 215


Cybersecurity recommended secure hardening guidelines

• Perform periodic account maintenance (remove unused accounts).


• Ensure password length, complexity and expiration requirements are appropriately set, particularly for all administrative
accounts (e.g., minimum 10 characters, mix of upper- and lower-case and special characters, and expire every 90 days, or
otherwise in accordance with your organization’s policies).
• Enforce session time-out after a period of inactivity.

5.2.2.5.1 Description of the User management in the Network Module:


• User and profiles management: (Navigate to Settings>>>Users)
Add users (admin, operator, viewer)
Remove users
Edit users
• Password/Account/Session management: (Navigate to Settings>>>Users)
Password strength rules – Minimum length/Minimum upper case/Minimum lower case/Minimum digit/Special character
Account expiration – Number of days before the account expiration/Number of tries before blocking the account
Session expiration – No activity timeout/Session lease time
See "Default settings parameters" in the embedded help for (recommended) default values.
Additionally, it is possible to enable account expiration to force users renew their password periodically.
• Default credentials: admin/admin
The change of the default "admin" password is enforced at first connection.
It is also recommended to change the default "admin" user name through the Settings>>>Users or Settings>>>Local
users page.
Follow embedded help for instructions on how to edit a user account.
• Local and Trusted remote certificate configuration: (Navigate to Settings>>>Certificate)
Follow embedded help for instructions on how to configure it.
• Supported authentication: LDAP and Radius, follow embedded help for instructions on how to configure it.

5.2.2.6 Time Synchronization


Many operations in power grids and IT networks heavily depend on precise timing information.
Ensure the system clock is synchronized with an authoritative time source (using manual configuration, NTP). (Navigate to
Settings>>>General>>>Time&date settings)
Follow embedded help for instructions on how to configure it.

5.2.2.7 Deactivate unused features


Network module provides multiple options to upgrade firmware, change configurations, set power schedules, etc. The device also
provide multiple options to connect with the device i.e. SSH, SNMP,SMTP,HTTPS etc. Services like SNMPv1 are considered
insecure and Eaton recommends disabling all such insecure services.
• It is recommended to disable unused physical ports like USB and SD card.
• Disable insecure services like SNMP v1

5.2.2.8 Network Security


Network module supports network communication with other devices in the environment. This capability can present risks if it’s
not configured securely. Following are Eaton recommended best practices to help secure the network. Additional information
about various network protection strategies is available in Eaton Cybersecurity Considerations for Electrical Distribution Systems
[R1].
Eaton recommends segmentation of networks into logical enclaves, denying traffic between segments except that which is
specifically allowed, and restricting communication to host-to-host paths (for example, using router ACLs and firewall rules). This
helps to protect sensitive information and critical services and creates additional barriers in the event of a network perimeter
breach. At a minimum, a utility Industrial Control Systems network should be segmented into a three-tiered architecture (as
recommended by NIST SP 800-82[R3]) for better security control.
Communication Protection: Network module provides the option to encrypt its network communications. Please ensure that
encryption options are enabled. You can secure the product’s communication capabilities by taking the following steps:

Securing the Network Management Module – 216


Cybersecurity recommended secure hardening guidelines

• Local and Trusted remote certificate configuration: (Navigate to Settings>>>Certificate)


Follow embedded help for instructions on how to configure it.
Eaton recommends opening only those ports that are required for operations and protect the network communication using
network protection systems like firewalls and intrusion detection systems / intrusion prevention systems. Use the information
below to configure your firewall rules to allow access needed for Network module to operate smoothly
• Navigate to Information>>>Specifications/Technical characteristics>>>Port to get the list of all ports and services running on
the device.
• SNMP V1/SNMP V3 can be disabled or configured by navigating to Settings>>>SNMP.
Follow embedded help for instructions on how to configure it.
• If available, Modbus and Bacnet can be configured by navigating to Settings>>>Protocols or Settings>>>Industrial protocols.
Follow embedded help for instructions on how to configure it.

5.2.2.9 Remote access


Remote access to devices/systems creates another entry point into the network. Strict management and validation of termination
of such access is vital for maintaining control over overall ICS security.
Remote access capabilities and permissions can be configured in Settings>>>Remote users for LDAP and Radius.
Follow embedded help for instructions on how to configure it.

5.2.2.10 Logging and Event Management


Navigate to Information>>>List of events codes to get log information and how to export it.
Good Practices
• Eaton recommends logging all relevant system and application events, including all administrative and maintenance activities.
• Logs should be protected from tampering and other risks to their integrity (for example, by restricting permissions to access
and modify logs, transmitting logs to a security information and event management system, etc.).
• Ensure that logs are retained for a reasonable and appropriate length of time.
• Review the logs regularly. The frequency of review should be reasonable, taking into account the sensitivity and criticality of
the system | device and any data it processes.

5.2.2.11 Malware defenses


Eaton recommends deploying adequate malware defenses to protect the product or the platforms used to run the Eaton product.

5.2.2.12 Secure Maintenance


Troubleshooting information are available in the embedded help for diagnostic purposes.
The Network module includes also Servicing, Securing sections to allow a service engineer with help from site administrator to
trouble shoot the device functionality.
• Configuring/Commissioning/Testing LDAP
• Pairing agent to the Network Module
• Powering down/up applications (examples)
• Checking the current firmware version of the Network Module
• Accessing to the latest Network Module firmware/driver/script
• Upgrading the card firmware (Web interface / shell script)
• Changing the RTC battery cell
• Updating the time of the Network Module precisely and permanently (ntp server)
• Synchronizing the time of the Network Module and the UPS
• Changing the language of the web pages
• Resetting username and password
• Recovering main administrator password
• Switching to static IP (Manual) / Changing IP address of the Network Module
• Reading device information in a simple way
• Subscribing to a set of alarms for email notification
• Saving/Restoring/Duplicating Network module configuration settings
• Configuring user permissions through profiles
• Decommissioning the Network Management module

Securing the Network Management Module – 217


Cybersecurity recommended secure hardening guidelines

Eaton publishes patches and updates for its products to protect them against vulnerabilities that are discovered. Eaton encourages
customers to maintain a consistent process to promptly monitor for and install new firmware updates.
Good Practices
• Update device firmware prior to putting the device into production.
• Thereafter, apply firmware updates and software patches regularly.
Please check Eaton’s cybersecurity website for information bulletins about available firmware and software updates.
• Navigate in the help to Contextual help>>>Card>>>Administration to get information on how to upgrade the Network
Module.
• Eaton also has a robust vulnerability response process. In the event of any security vulnerability getting discovered in its
products, Eaton patches the vulnerability and releases information bulletin through its cybersecurity web site - https://
eaton.com/cybersecurity and patch through www.eaton.com/downloads.

5.2.2.13 Business Continuity / Cybersecurity Disaster Recovery

5.2.2.13.1 Plan for Business Continuity / Cybersecurity Disaster Recovery


Eaton recommends incorporating the Network module into the organization’s business continuity and disaster recovery plans.
Organizations should establish a Business Continuity Plan and a Disaster Recovery Plan and should periodically review and, where
possible, exercise these plans. As part of the plan, important system | device data should be backed up and securely stored,
including:
• Updated firmware for the Network module. Make it a part of standard operating procedure to update the backup copy as
soon as the latest firmware is updated.
• The current configuration.
• Documentation of the current permissions / access controls, if not backed up as part of the configuration.
The following section describes the details of failures states and backup functions:
• Communication and power status indicators: Navigate in the help to Information>>>Front panel connectors and LED
indicators.
• Configuration of backup and recovery: Navigate in the help to Servicing the Network Management Module>>>Saving/
Restoring/Duplicating Network module configuration settings.

5.2.2.14 Sensitive Information Disclosure


Eaton recommends that sensitive information (i.e. connectivity, log data, personal information) that may be stored by Network
module be adequately protected through the deployment of organizational security practices.
• Full name
• Email
• Phone
• Organization
• The mail credentials in the CDS storage
• PKI signed server’s (HTTP + MQTT) certificate and associated private key
• Server’s (HTTP + MQTT) self-signed private keys (they are self-generated by the device upon user request, so unique per
device)
• Username’s (in clear) and their “vCard” (Full name, Organization, Phone, Email, …)
• Hashed passwords
• IP addresses, hostnames (DNS, Gateway, mail servers, …) of customer network devices (in database or logs)
• Maintenance report AES key/password

5.2.2.15 Decommissioning or Zeroization


It is a best practice to purge data before disposing of any device containing data. Guidelines for decommissioning are provided in
NIST SP 800-88. Eaton recommends that products containing embedded flash memory be securely destroyed to ensure data is
unrecoverable.

Securing the Network Management Module – 218


Cybersecurity recommended secure hardening guidelines

*Figure and data from NIST SP800-88


• Embedded Flash Memory on Boards and Devices
• Eaton recommends the following methods for disposing of motherboards, peripheral cards such as network adapters, or any
other adapter containing non-volatile flash memory.
• Clear: If supported by the device, reset the state to original factory settings.
Navigate to Securing the Network Management Module>>>Decommissioning the Network Management module.
• Purge: If the flash memory can be easily identified and removed from the board, the flash memory may be destroyed
independently of the board that contained the flash memory. Otherwise, the whole board should be destroyed.
For the Network module the whole board should be destroyed.
• Destroy: Shred, disintegrate, pulverize, or Incinerate by burning the device in a licensed incinerator.

5.2.3 References
[R1] Cybersecurity Considerations for Electrical Distribution Systems (WP152002EN): http://www.eaton.com/ecm/groups/public/
@pub/@eaton/@corp/documents/content/pct_1603172.pdf
[R2] Cybersecurity Best Practices Checklist Reminder (WP910003EN): http://www.cooperindustries.com/content/dam/public/
powersystems/resources/library/1100_EAS/WP910003EN.pdf
[R3] NIST SP 800-82 Rev 2, Guide to Industrial Control Systems (ICS) Security, May 2015: https://nvlpubs.nist.gov/nistpubs/
SpecialPublications/NIST.SP.800-82r2.pdf
[R4] National Institute of Technology (NIST) Interagency “Guidelines on Firewalls and Firewall Policy, NIST Special Publication
800-41”, October 2009: http://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication800-41r1.pdf

Securing the Network Management Module – 219


Configuring user permissions through profiles

[R5] NIST SP 800-88, Guidelines for Media Sanitization, September 2006: http://ws680.nist.gov/publication/get_pdf.cfm?
pub_id=50819
[R6] Cybersecurity Best Practices for Modern Vehicles - NHTSA: https://www.nhtsa.gov/staticfiles/nvs/pdf/
812333_CybersecurityForModernVehicles.pdf
[R7] A Summary of Cybersecurity Best Practices - Homeland Security: https://www.hsdl.org/?view&did=806518
[R8] Characterization of Potential Security Threats in Modern Automobiles - NHTSA: https://www.nhtsa.gov/DOT/NHTSA/NVS/
Crash%20Avoidance/Technical%20Publications/2014/812074_Characterization_PotentialThreatsAutos(1).pdf
[R9] Threat Modeling for Automotive Security Analysis: http://nvlpubs.nist.gov/nistpubs/Legacy/SP/
nistspecialpublication800-41r1.pdf

5.3 Configuring user permissions through profiles


The user profile can be defined when creating a new users or changed when modifying an existing one.
Refer to the section Contextual help>>>Settings>>>Local users in the settings.

5.4 Decommissioning the Network Management module


With the increased frequency of reported data breaches, it’s becoming more and more necessary for companies to implement
effective and reliable decommissioning policies and procedures.
In order to protect the data stored on retired IT equipment from falling into the wrong hands, or a data breach, we recommend to
follow below decommissioning steps:
1- Sanitize the Network Module
Sanitization erases all the data (user name and password, certificates, keys, settings, logs...).
To sanitize the Network Module refer to the Contextual help>>>Maintenance>>>Services>>>Sanitization section.
2- Unmount the Network Module from the device.
Unscrew the Network Module and remove it from the slot.

Securing the Network Management Module – 220


Description and features

6 Servicing the EMP

6.1 Description and features


Unable to render include or excerpt-include. Could not retrieve page.

The optional Environmental Monitoring Probe


Unable to render include or excerpt-include. Could not retrieve page.

enables you to collect temperature and humidity readings and monitor the environmental data remotely.
You can also collect and retrieve the status of one or two dry contact devices (not included).
Up to 3 Environmental Monitoring Probe can be daisy chained on one device.
You can monitor readings remotely using SNMP or a standard Web browser through the Network module.
This provides greater power management control and flexible monitoring options.
The EMP device is delivered with a screw and screw anchor, nylon fasteners, tie wraps, and magnets. You can install the device
anywhere on the rack or on the wall near the rack.

For more information, refer to the device manual.

The EMP has the following features:


• The hot-swap feature simplifies installation by enabling you to install the probe safely without turning off power to the device
or to the loads that are connected to it.
• The EMP monitors temperature and humidity information to help you protect critical equipment.
• The EMP measures temperatures from 0°C to 70°C with an accuracy of ±2°C.
• The EMP measures relative humidity from 10% to 90% with an accuracy of ±5%.
• The EMP can be located some distance away from the device with a CAT5 network cable up to 50m (165 ft) long.
• The EMP monitors the status of the two user-provided contact devices.
• Temperature, humidity, and contact closure status can be displayed through a Web browser through the Network module or
LCD interface (if available)
• A Temperature and Humidity Offset can be set.

6.2 Unpacking the EMP


The
Unable to render include or excerpt-include. Could not retrieve page.

sensor will include the following:


• Dry contact terminal block
• Installation instructions
• USB to RS485 converter
• RJ45 female to female connector
• Wall mounting screw and anchor
• Rack mounting screw nut and washer
• Tie wraps (x2)
• Nylon fastener

Packing materials must be disposed of in compliance with all local regulations concerning waste.
Recycling symbols are printed on the packing materials to facilitate sorting.

Servicing the EMP – 221


Installing the EMP

6.3 Installing the EMP


6.3.1 Defining EMPs address and termination

6.3.1.1 Manual addressing


Address must be defined before the EMP power-up otherwise the changes won't be taken into account.
o not set Modbus address to 0, otherwise the EMP will not be detected.

Define different address for all the EMPs in the daisy-chain.


Set the RS485 termination (TER) to 1 on the last EMP of the daisy chain, set it to 0 on all the other EMPs.

6.3.1.1.1 Example: manual addressing of 3 EMPs connected to the Device

Green LED of the TO DEVICE RJ45 connector shows if the EMP is powered by the Network module.

6.3.2 Mounting the EMP


The EMP includes magnets, cable ties slots and keyholes to enable multiple ways of mounting it on your installation.

Servicing the EMP – 222


Installing the EMP

Bottom mounting capabilities: Side


mounting:
• magnets
• keyholes • magnets
• tie wraps • tie wraps
• nylon fastener

6.3.2.1 Rack mounting with keyhole example


To mount the EMP on the rack, use the supplied screw, washer and nut. Then, mount the EMP on the
screw and tighten it.

6.3.2.2 Rack mounting with tie wraps example


To mount the EMP on the door of the rack, use the supplied cable ties.

Servicing the EMP – 223


Installing the EMP

Bottom mounting Side mounting

6.3.2.3 Wall mounting with screws example


To mount the EMP on the wall close to the rack, use the supplied screw and screw anchor. Then, mount
the EMP on the screw and tighten it.

6.3.2.4 Wall mounting with nylon fastener example


To mount the EMP within the enclosure environment, attach one nylon fastener to the EMP and the other nylon fastener to an
enclosure rail post. Then, press the two nylon strips together to secure the EMP to the rail post.

Cut nylon fastener and stick it on the EMP bottom on the location highlighted below,this will prevent to interfere
with the EMP data acquisition parts.

Servicing the EMP – 224


Installing the EMP

6.3.3 Cabling the first EMP to the device

6.3.3.1 Available Devices

6.3.3.2 Connecting the EMP to the device


Address must be defined before the EMP power-up otherwise the changes won't be taken into account.
Do not set Modbus address to 0, otherwise the EMP will not be detected.

6.3.3.2.1 Material needed:


• EMP
• RJ45 female/female connector (supplied in EMP accessories)
• USB to RS485 converter cable (supplied in EMP accessories)
• Ethernet cable (not supplied).
• Device

6.3.3.2.2 Connection steps

STEP 1 – Connect the "USB to RS485 converter cable" to the USB port of the Device.
STEP 2 – Connect the "USB to RS485 converter cable" to the RJ45 female/female connector.
STEP 3 – Connect the Ethernet cable to the other end of the RJ45 female/female connector.
STEP 4 – Connect the other end of the Ethernet cable to the RJ-45 port on the EMP (FROM DEVICE).

Use the supplied tie wraps to secure the "RS485 to USB cable" to the Network cable.

6.3.4 Daisy chaining EMPs


Address must be defined before EMP power-up; otherwise, the changes will not be applied.
Do not set Modbus address to 0; otherwise, the EMP will not be detected.

6.3.4.1 Material needed:


• First EMP connected to the device (refer to previous section)

Servicing the EMP – 225


Installing the EMP

• Additional EMPs
• 2 x Ethernet cable (not supplied).
• Device

6.3.4.2 Connection steps

STEP 1 – Connect the Ethernet cable to the "TO SENSORS" port of the first EMP, and to the "FROM DEVICE" port of the second
EMP.
STEP 2 – Connect the Ethernet cable to the "TO SENSORS" port of the second EMP, and to the "FROM DEVICE" port of the third
EMP.

Up to 3 EMP can be daisy chained on one device.

6.3.5 Connecting an external contact device

To connect an external device to the EMP:


STEP 1 – Connect the external contact closure inputs to the terminal block on the EMP (see the table and the figure below):
• External contact device 1. Connect the return and signal input wires from device 1 to screw terminals 1.
• External contact device 2. Connect the return and signal input wires from device 2 to screw terminals 2.

Servicing the EMP – 226


Commissioning the EMP

STEP 2 – Tighten the corresponding tightening screws on top of the EMP to secure the wires.

6.4 Commissioning the EMP


6.4.1 On the Network Module device
STEP 1 – Connect to the Network Module
• On a network computer, launch a supported web browser. The browser window appears.
• In the Address/Location field, enter the IP address of the Network Module.
• Enter username, password and click on Login.
STEP 2 – Navigate to Environment menu:

STEP 3 – Proceed to the commissioning, refer to the contextual help for details.
• Click Discover. The EMP connected to the Network module appears in the table.

When discovered, the orange LEDs of the EMP RJ45 connectors shows the data traffic.
If the discovery process fails refer to the troubleshooting section.

• Press the pen logo to edit EMP information and access its settings.
• Click Define offsets to define temperature or humidity offsets if needed.
STEP 4 – Define alarm configuration, refer to the contextual help for details.
• Select the Alarm configuration page.
• Enable or disable alarms.
• Define thresholds, hysteresis and severity of temperature, humidity and dry contacts alarms.

6.5 Using the EMP for temperature compensated battery charging


This section applies only to UPS that provides temperature compensated battery charging option.

Address must be defined before EMP power-up; otherwise, the changes will not be applied.
Do not set Modbus address to 0; otherwise, the EMP will not be detected.
Define a unique address for all the EMPs in the daisy-chain.
Set the RS485 termination (TER) to 1 on the last EMP of the daisy chain. On other EMPs this should be set to 0.

Servicing the EMP – 227


Using the EMP for temperature compensated battery charging

6.5.1 Addressing the EMP


Set the address 31 to the sensor dedicated to the battery room temperature:
• Set all the Modbus address switches to 1 to set the EMP to the address 31 as indicated on the picture below:

6.5.2 Commissioning the EMP


Refer to the section Contextual help>>>Environment>>>Commissioning/Status.

6.5.3 Enabling temperature compensated battery charging in the UPS


The temperature compensated battery charging feature needs to be enabled in the UPS.

To enable the temperature compensated battery charging, refer to the UPS user manual.

Servicing the EMP – 228


Front panel connectors and LED indicators

7 Information

7.1 Front panel connectors and LED indicators

Nbr Name Description

Network connector Ethernet port

Network speed LED Flashing green sequences:

• 1 flash — Port operating at 10Mbps


• 2 flashes — Port operating at 100Mbps
• 3 flashes — Port operating at 1Gbps

Network link/activity LED • Off — UPS Network Module is not connected to the network.
• Solid yellow — UPS Network Module is connected to the network, but no activity
detected.
• Flashing yellow — UPS Network Module is connected to the network and sending
or receiving data.

AUX connector For Network Module accessories only.

Do not use for general power supply or USB charger.

Restart button Ball point pen or equivalent will be needed to restart:

• Short press (<6s) — Safe software restart (firmware safely shutdown before
restart).
• Long press (>9s) — Forced hardware restart.

ON LED Flashing green — Network Module is operating normally.

Warning LED Solid red — Network Module is in error state.

Boot LEDs Solid green and flashing red — Network Module is starting boot sequence.

Information – 229
Specifications/Technical characteristics

Settings/UPS data connector Configuration port.


Access to Network Module’s web interface through RNDIS (Emulated Network port).
Access to the Network Module console through Serial (Emulated Serial port).

Modbus connector Detachable terminal block with push-in connections: 0V / T+ / T- / R+ / R-

Shield Depending on the cabling this location may be used as a shield reference.

7.2 Specifications/Technical characteristics


Physical characteristics

Dimensions (wxdxh) 132 x 66 x 42 mm | 5.2 x 2.6 x 1.65 in

Weight 70 g | 0.15 lb

RoHS 100% compatible

Storage

Storage temperature -25°C to 70°C (14°F to 158°F)

Ambient conditions

Operating temperature 0°C to 70°C (32°F to 158°F)

Relative humidity 5%-95%, noncondensing

Module performance

Module input power 5V-12V ±5% | 1A

AUX output power 5V ±5% | 200mA

Date/Time backup CR1220 battery coin cell | The RTC is able to keep the date and the time when Network Module is OFF

Functions

Languages English, French, German, Italian, Japanese, Russian, Simplified Chinese, Spanish, Traditional Chinese

Alarms/Log Email, SNMP trap, web interface / Log on events

Network Gigabit ETHERNET, 10/100/1000Mb/s, auto neg., HTTP 1.1, SNMP V1/V2C, SNMP V3, NTP, SMTP, DHCP

Security Restricted to TLS 1.2

Supported MIBs xUPS MIB | ATS2 MIB | Standard IETF UPS MIB (RFC 1628) | Sensor MIB

Browsers Google Chrome, Firefox, Safari

Information – 230
Default settings and possible parameters

Settings (default values)

IP network DHCP enabled | NTP server: pool.ntp.org

Port 443 (https), 22 (ssh), 161 (snmp), 162 (snmp trap), 25 (smtp), 8883 (mqtts), 123 (ntp), 5353 (mdns-sd), 80 (http), 514
(syslog),636 (LDAP), 1812 (RADIUS)

Web interface access User name: admin | Password: admin


control

Settings/Device data USB RNDIS Apipa compatible | IP address: 169.254.0.1 | Subnet mask: 255.255.0.0
connector

7.3 Default settings and possible parameters


7.3.1 Meters

Default settings and possible parameters - Meters

Default setting Possible parameters

Meters/Logs Log measures every — 60s Log measures every — 3600s maximum

7.3.2 Settings

Default settings and possible parameters - General

Default setting Possible parameters

System details Location — empty Location — 31 characters maximum


Contact — empty Contact — 255 characters maximum
System name — empty System name — 255 characters maximum
Time & date settings — Manual (Time zone: Time & date settings — Manual (Time zone: selection
Europe/Paris) on map/Date) / Dynamic (NTP)

Information – 231
Default settings and possible parameters

Email notification settings No email 5 configurations maximum


Custom name — 128 characters maximum
Email address — 128 characters maximum
Hide IP address from the email body — enable/
disabled
Status — Active/Inactive

• Alarm notifications
Active — No/Yes
All card events – Subscribe/Attach logs
Critical alarm – Subscribe/Attach logs
Warning alarm – Subscribe/Attach logs
Info alarm – Subscribe/Attach logs

All device events – Subscribe/Attach


measures/Attach logs
Critical alarm – Subscribe/Attach measures
/Attach logs
Warning alarm – Subscribe/Attach
measures/Attach logs
Info alarm – Subscribe/Attach measures/
Attach logs

Always notify events with code


Never notify events with code

• Schedule report
Active — No/Yes
Recurrence – Every day/Every week/Every
month
Starting – Date and time
Card events – Subscribe/Attach logs
Device events – Subscribe/Attach
measures/Attach logs

SMTP settings Server IP/Hostname — blank Server IP/Hostname — 128 characters maximum
SMTP server authentication — disabled SMTP server authentication — disable/enable
(Username/Password — 128 characters maximum)
Port — 25
Port — x-xxx
Default sender address —
[email protected] Sender address — 128 characters maximum
Hide IP address from the email body — disabled Hide IP address from the email body — enable/
disabled
Security — enabled
Secure SMTP connection — enable/disable
Verify certificate authority — disabled
Verify certificate authority — disable/enable
SMTP server authentication — disabled

Default settings and possible parameters - Global user settings and Local users

Default setting Possible parameters

Information – 232
Default settings and possible parameters

Password settings Minimum length — enabled (8) Minimum length — enable (6-32)/disable
Minimum upper case — enabled (1) Minimum upper case — enable (0-32)/disable
Minimum lower case — enabled (1) Minimum lower case — enable (0-32)/disable
Minimum digit — enabled (1) Minimum digit — enable (0-32)/disable
Special character — enabled (1) Special character — enable (0-32)/disable

Password expiration Number of days until password expires — disabled Number of days until password expires — disable/
enable (1-99999)
Main administrator password never expires —
disabled Main administrator password never expires —
disable/enable

Lock account Lock account after xx invalid tries — disabled Lock account after xx invalid tries — disable/enable
(1-99)
Main administrator account never blocks — disabled
Main administrator account never blocks — disable/
enable

Account timeout No activity timeout — 60 minutes No activity timeout — 1-60 minutes


Session lease time — 120 minutes Session lease time — 60-720 minutes

Local users 1 user only: 20 users maximum:

• Active — Yes • Active — Yes/No


• Profile — Administrator • Profile — Administrator/Operator/Viewer
• Username — admin • Username — 255 characters maximum
• Full Name — blank • Full Name — 128 characters maximum
• Email — blank • Email — 128 characters maximum
• Phone — blank • Phone — 64 characters maximum
• Organization — blank • Organization — 128 characters maximum

Default settings and possible parameters - Remote users

Default setting Possible parameters

Information – 233
Default settings and possible parameters

LDAP Configure Configure

• Active – No • Active – No/yes


• Security • Security
SSL – SSL SSL – None/Start TLS/SSL
Verify server certificate – enabled Verify server certificate – disabled/enabled
• Primary server • Primary server
Name – Primary Name – 128 characters maximum
Hostname – blank Hostname – 128 characters maximum
Port – 636 Port – x-xxx
• Secondary server • Secondary server
Name – blank Name – 128 characters maximum
Hostname – blank Hostname – 128 characters maximum
Port – blank Port – x-xxx
• Credentials • Credentials
Anonymous search bind – disabled Anonymous search bind – disabled/
Search user DN – blank enabled
Password – blank Search user DN – 1024 characters
• Search base maximum
Search base DN – dc=example,dc=com Password – 128 characters maximum
• Request parameters • Search base
User base DN – Search base DN – 1024 characters
ou=people,dc=example,dc=com maximum
User name attribute – uid • Request parameters
UID attribute – uidNumber User base DN – 1024 characters
Group base DN – maximum
ou=group,dc=example,dc=com
Group name attribute – gid User name attribute – 1024 characters
GID attribute – gidNumber maximum
UID attribute – 1024 characters maximum
Profile mapping – no mapping
Group base DN – 1024 characters
Users preferences maximum
• Language –
English Group name attribute – 1024 characters
maximum
GID attribute – 1024 characters maximum
• Temperature unit – °C (Celsius) Profile mapping – up to 5 remote groups mapped to
• Date format – m/d/Y local profiles
• Time format – hh:mm:ss (24h)
Users preferences

• Language – English, French, German,


Italian, Japanese, Russian, Simplified
Chinese, Spanish, Traditional Chinese
• Temperature unit – °C (Celsius)/°F
(Fahrenheit)
• Date format – MM-DD-YYYY / YYY-MM-
DD / DD-MM-YYY / DD.MM.YYY / DD/
MM/YYY / DD MM YYYY
• Time format – hh:mm:ss (24h) / hh:mm:ss
(12h)

RADIUS Configure Configure

• Active – No • Active – Yes/No


• Retry number – 0 • Retry number – 0 to 128
• Primary server • Primary server
Name – blank Name – 128 characters maximum
Secret – blank Address – 128 characters maximum
Address – blank Secret – 128 characters maximum
UDP port – 1812 UDP port – 1 to 65535
Time out – 3 Time out – 3 to 60

Information – 234
Default settings and possible parameters

• Secondary server • Secondary server


Name – blank Name – 128 characters maximum
Secret – blank Address – 128 characters maximum
Address – blank Secret – 128 characters maximum
UDP port – 1812 UDP port – 1 to 65535
Time out – 3 Time out – 3 to 60
Users preferences Users preferences

• Language – • Language – English, French, German,


English Italian, Japanese, Russian, Simplified
Chinese, Spanish, Traditional Chinese
• Temperature unit – °C (Celsius)
• Temperature unit – °C (Celsius) • Date format – MM-DD-YYYY
• Date format – m/d/Y • Time format – hh:mm:ss (24h)
• Time format – hh:mm:ss (24h)

Default settings and possible parameters - Network & Protocol

Default setting Possible parameters

IPV4 Mode — DHCP Mode — DHCP/Manual (Address/Netmask/Gateway)

IPV6 Enable — checked Enabled — Active/Inactive

Mode — DHCP Mode — DHCP/Manual (Address/Prefix/Gateway)

DNS/DHCP Hostname — device-[MAC address] Hostname — 128 characters maximum


Mode — DHCP Mode :DHCP/Manual (Domain name/Primary DNS/
Secondary DNS)

Ethernet Configuration — Auto negotiation Configuration — Auto negotiation - 10Mbps - Half


duplex - 10Mbps - Full duplex - 100Mbps - Half
duplex - 100Mbps - Full duplex - 1.0 Gbps - Full
duplex

HTTPS Port — 443 Port — x-xxx


Disable Port 80 (http) - Not disabled Disable Port 80 (http) - Disabled

Syslog Inactive Inactive/Active

• Server#1 • Server#1
Name – Primary Name – 128 characters maximum
Status – Disabled Status – Disabled/Enabled
Hostname – empty Hostname – 128 characters maximum
Port – 514 Port – x-xxx
Protocol – UDP Protocol – UDP/TCP
Message transfer method – Non transparent Message transfer method – Non transparent
framing framing
Using unicode byte order mask (BOM) – Using unicode byte order mask (BOM) –
disabled disable/enable

Information – 235
Default settings and possible parameters

• Server#2 • Server#2
Name – empty Name – 128 characters maximum
Status – Disabled Status – Disabled/Enabled
Hostname – empty Hostname – 128 characters maximum
Port – 514 Port – x-xxx
Protocol – UDP Protocol – UDP/TCP
Message transfer method – DIsabled in UDP Message transfer method (in TCP) – Octet
counting/Non transparent framing
Using unicode byte order mask (BOM) –
disabled Using unicode byte order mask (BOM) –
disable/enable

Default settings and possible parameters - SNMP

Default setting Possible parameters

SNMP Activate SNMP — disabled Activate SNMP — disable/enable


Port — 161 Port — x-xxx
SNMP V1 — disabled SNMP V1 — disable/enable

• Community #1 — public • Community #1 — 128 characters


Enabled — Inactive maximum
Access — Read only Enabled — Inactive/Active
Access — Read only
• Community #2 — private
Enabled — Inactive • Community #2 — 128 characters
Access — Read/Write maximum
Enabled — Inactive/Active
SNMP V3 — enabled
Access — Read/Write
• User #1 — readonly
SNMP V3 — disable/enable
Enabled — Inactive
Access — Read only • User #1 — 32 characters maximum
Authentication — Auth (SHA-1) Enabled — Inactive/Active
Password — empty Access — Read only/Read-Write
Confirm password — empty Authentication — Auth (SHA-1)/None
Privacy — Secured - AES Password — 128 characters maximum
Key — empty Confirm password — 128 characters
Confirm key — empty maximum
Privacy — Secured - AES/None
• User#2 — readwrite
Key — 128 characters maximum
Enabled — Inactive
Confirm key — 128 characters maximum
Access — Read/Write
Authentication — Auth (SHA-1) • User#2 — 32 characters maximum
Password — empty Enabled — Inactive/Active
Confirm password — empty Access — Read only/Read-Write
Privacy — Secured - AES Authentication — Auth (SHA-1)/None
Key — empty Password — 128 characters maximum
Confirm key — empty Confirm password — 128 characters
maximum
Privacy — Secured - AES/None
Key — 128 characters maximum
Confirm key — 128 characters maximum

Trap receivers No trap Enabled — No/Yes


Application name — 128 characters maximum
Hostname or IP address — 128 characters maximum

Information – 236
Default settings and possible parameters

Port — x-xxx
Protocol — V1/V2C/V3
Trap community — 128 characters maximum

Default settings and possible parameters - Industrial protocols

Default setting Possible parameters

Modbus RTU Modbus RTU — Inactive Modbus RTU — Inactive/Active


Baud rate (bps) — 19200 Baud rate (bps) —
1200/2400/4800/9600/19200/38400/57600/1152
Parity — Even 00
Stop bits – 1 Parity — None/Even/Odd
Stop bits – 1/2

Default setting Possible parameters

Modbus TCP Modbus TCP — Inactive Modbus TCP — Inactive/Active


Port — 502 Port — x-xxx

Default setting Possible parameters

Mapping configuration No mapping Custom name – 128 characters maximum


Map – Eaton ModbusMS compatible, Eaton
PowerXpert UID 0 compatible, Card System
Information
Transport – RTU/TCP
Access – None/Read only/Read/Write
Illegal read behaviour – Return exception/Return
zeros
IP filtering – IP address
Coil/register base address shift – No shift/Shift
by 1 (JBUS)

Default setting Possible parameters

BACnet BACnet IP — Inactive BACnet IP — Inactive/Active


Device Id — Automatically generated, must be
unique, 4194304 characters maximum
Device Name — Automatically generated, must
be unique, 1-255 characters maximum, only Latin
letters, numbers, spaces, '_' and '!' symbols
Device connection control password — 6-20
characters maximum
Local port — 1-65535 characters maximum (as
all the other UDP and TCP ports)
MAC address — MAC address format
Broadcast management device — Inactive/Active

Information – 237
Default settings and possible parameters

BBMD BACnet/IP device — IP address format


BBMD Time to live — 30-1800 seconds

Default settings and possible parameters - Certificate

Default setting Possible parameters

Local certificates Common name — 64 characters maximum


Common name — Service + Hostname + selfsigned Country — Country code
Country — FR State or Province — 64 characters maximum
State or Province — 38 City or Locality — 64 characters maximum
City or Locality — Grenoble Organization name — 64 characters maximum
Organization name — Eaton Organization unit — 64 characters maximum
Organization unit — Power quality Contact email address — 64 characters maximum
Contact email address — blank

7.3.3 Sensors alarm configuration

Default settings and possible parameters - Environment Alarm configuration

Default setting Possible parameters

Temperature Enabled — No Enabled — No/Yes


Low critical – 0°C/32°F low critical<low warning<high warning<high critical
Low warning – 10°C/50°F
High warning – 70°C/158°F
High critical – 80°C/176°F

Humidity Enabled — No Enabled — No/Yes


Low critical – 10% 0%<low critical<low warning<high warning<high
critical<100%
Low warning – 20%
High warning – 80%
High critical – 90%

Dry contacts Enabled — No Enabled — No/Yes


Alarm severity – Warning Alarm severity – Info/Warning/Critical

7.3.4 User profile

Information – 238
Default settings and possible parameters

Default settings and possible parameters - User profile

Default setting Possible parameters

Profile Account details: Account details:

• Full name — Administrator • Full name — 128 characters maximum


• Email — blank • Email — 128 characters maximum
• Phone — blank • Phone — 64 characters maximum
• Organization — blank • Organization — 128 characters maximum
Preferences: Preferences:

• Language — • Language — English, French, German,


English Italian, Japanese, Russian, Simplified
Chinese, Spanish, Traditional Chinese
• Date format — MM-DD-YYYY / YYY-MM-
• Date format — MM-DD-YYYY DD / DD-MM-YYY / DD.MM.YYY / DD/
• Time format — hh:mm:ss (24h) MM/YYY / DD MM YYYY
• Temperature — °C (Celsius) • Time format — hh:mm:ss (24h) /
hh:mm:ss (12h)
• Temperature — °C (Celsius)/°F
(Fahrenheit)

Information – 239
Access rights per profiles

7.4 Access rights per profiles


7.4.1 Home

Administrator Operator Viewer

Home

7.4.2 Meters

Administrator Operator Viewer

Meters

Battery health: Launch test/Abort

Logs configuration

7.4.3 Controls

Administrator Operator Viewer

Control

7.4.4 Protection

Administrator Operator Viewer

Protection/Scheduled
shutdowns

Administrator Operator Viewer

Protection/Agent list

Administrator Operator Viewer

Protection/Agent settings

Information – 240
Access rights per profiles

Administrator Operator Viewer

Protection/Sequence

7.4.5 Environment

Administrator Operator Viewer

Environment/Commissioning

Environment/Status

Administrator Operator Viewer

Environment/Alarm
configuration

Administrator Operator Viewer

Environment/Information

7.4.6 Settings

Administrator Operator Viewer

General

Administrator Operator Viewer

Local users

Administrator Operator Viewer

Remote users

Administrator Operator Viewer

Network & Protocols

Administrator Operator Viewer

SNMP

Information – 241
Access rights per profiles

Administrator Operator Viewer

Industrial protocols/Modbus*

Administrator Operator Viewer

Industrial protocols/BACnet*

*for only

Administrator Operator Viewer

Certificate

Administrator Operator Viewer

ATS

7.4.7 Maintenance

Administrator Operator Viewer

System information

Administrator Operator Viewer

Firmware

Administrator Operator Viewer

Services

Administrator Operator Viewer

Resources

Administrator Operator Viewer

System logs

7.4.8 Alarms

Information – 242
Access rights per profiles

Administrator Operator Viewer

Alarm list

Export

Clear

7.4.9 User profile

Administrator Operator Viewer

User profile

Administrator Operator Viewer

Legal information

7.4.10 Contextual help

Administrator Operator Viewer

Contextual help

Full documentation

7.4.11 CLI commands

Administrator Operator Viewer

get release info

Administrator Operator Viewer

history

Administrator Operator Viewer

ldap-test

Administrator Operator Viewer

logout

Information – 243
Access rights per profiles

Administrator Operator Viewer

maintenance

Administrator Operator Viewer

modbus_message_display*

*for only

Administrator Operator Viewer

modbus_statistics*

*for only

Administrator Operator Viewer

netconf (read-only) (read-only)

Administrator Operator Viewer

ping

ping6

Administrator Operator Viewer

reboot

Administrator Operator Viewer

save_configuration

restore_configuration

Administrator Operator Viewer

sanitize

Administrator Operator Viewer

Information – 244
List of event codes

ssh-keygen

Administrator Operator Viewer

time (read-only) (read-only)

Administrator Operator Viewer

traceroute

traceroute6

Administrator Operator Viewer

whoami

Administrator Operator Viewer

email-test

Administrator Operator Viewer

systeminfo_statistics

Administrator Operator Viewer

certificates

7.5 List of event codes


To get access to the Alarm log codes or the System log codes for email subscription, see sections below:

7.5.1 System log codes

To retrieve System logs, navigate to Contextual help>>>Maintenance>>>System logs section and press
the Download System logs button.

Below codes are the one to be used to add "Exceptions on events notification" on email sending configurations.
Some zeros maybe added in front of the code when displayed in emails or logs.

Information – 245
List of event codes

7.5.1.1 Critical

Code Severity Log message File

0801000 Alert User account - admin password reset to default logAccount.csv

0E00400 Critical The [selfsign/PKI] signed certificate of the <service> server is not valid logSystem.csv

0A00700 Error Network module file system integrity corrupted <f/w: xx.yy.zzzz> logUpdate.csv

0000D00 Error Card reboot due to database error logSystem.csv

0700200 Error Failed to start execution of script "<script description>". Client not registered. (<script logSystem.csv
uuid>)

0700400 Error Execution of script "<script description>" failed with return code: <script return code>. logSystem.csv
(<script uuid>)

0700500 Error Execution of script "<script description>" timeout! (<script uuid>) logSystem.csv

0700700 Alert Failed to prepare isolated environment for script execution. Protection service startup is logSystem.csv
aborted.

0700800 Error Starting execution of script "<script description>" failed. (<script uuid>) logSystem.csv

0700900 Error Failed to clean isolated environment after script execution. logSystem.csv

7.5.1.2 Warning

Code Severity Log message File

0A00200 Warning Network module upgrade failed <f/w: xx.yy.zzzz> logUpdate.csv

0A00A00 Warning Network module bootloader upgrade failed <f/w: xx.yy.zzzz> logUpdate.csv

0B00500 Warning RTC battery cell low logSystem.csv

0E00200 Warning New [self/PKI] signed certificate [generated/imported] for <service> server logSystem.csv

0E00300 Warning The [self/PKI] signed certificate of the <service> server will expires in <X> days logSystem.csv

0800700 Warning User account - password expired logAccount.csv

0800900 Warning User account- locked logAccount.csv

0C00100 Warning Unable to send email: Smtp server is unknown logSystem.csv

0C00200 Warning Unable to send email: Authentication method is not supported logSystem.csv

0C00300 Warning Unable to send email: Authentication error logSystem.csv

0C00500 Warning Unable to send email: Certificate Authority not recognized logSystem.csv

0C00600 Warning Unable to send email: Secure connection required logSystem.csv

0C00800 Warning Unable to send email: Unknown error logSystem.csv

Information – 246
List of event codes

0C00B00 Warning Unable to send email: Recipient not specified logSystem.csv

0F01300 Warning Card reboot due to Device FW upgrade logSystem.csv

1000F00 Warning <feature> settings partial restoration logSystem.csv

1001000 Warning <feature> settings restoration error logSystem.csv

1000C00 Warning Settings partial restoration logSystem.csv

1000D00 Warning Settings restoration error logSystem.csv

1200100 Warning Authentication to remote server failed logSystem.csv

1200200 Warning Fetching configuration file failed with HTTP reponse: <http_code> logSystem.csv

1200300 Warning Fetching configuration file failed with cURL code: <curl_code> logSystem.csv

1200400 Warning <protocol_type> protocol is disabled logSystem.csv

1200500 Warning Config file is empty logSystem.csv

1200600 Warning Config file size <real_file_size> exceeds maximum of bytes <max_size> logSystem.csv

1200800 Warning Invalid url logSystem.csv

1200900 Warning Internal error logSystem.csv

1200A00 Warning Wrong config file format logSystem.csv

1200B00 Warning Config file has been applied partially logSystem.csv

1200C00 Warning Config file restore failed with SRR code: <code> logSystem.csv

7.5.1.3 Info

Code Severity Log message File

0A01800 Info Start of a new log entry logSystem.csv

0A00500 Notice Network module sanitized logUpdate.csv

0A00900 Notice Network module bootloader upgrade success <f/w: xx.yy.zzzz> logUpdate.csv

0A00B00 Notice Network module bootloader upgrade started <f/w: xx.yy.zzzz> logUpdate.csv

0A00C00 Notice Periodic system integrity check started logUpdate.csv

0B00100 Notice Time manually changed logSystem.csv

0B00700 Notice NTP sever not available <NTP server address> logSystem.csv

0900100 Notice Session - opened logSession.csv

0900200 Notice Session - closed logSession.csv

0900300 Notice Session - invalid token logSession.csv

0900400 Notice Session - authentication failed logSession.csv

Information – 247
List of event codes

0300F00 Notice User action - network module admin password reset switch activated logSystem.csv

0E00500 Notice [Certificate authority/ Client certificate] <id> is added for <service> logSystem.csv

0E00600 Notice [Certificate authority/ Client certificate] <id> is revoked for <service> logSystem.csv

0700100 Info Start execution of script "<script description>". (<script uuid>) logSystem.csv

0700300 Info Execution of script "<script description>" succeeded. (<script uuid>) logSystem.csv

0700600 Info/Notice/ <Script execution log message> logSystem.csv


Error/Debug

0800100 Notice User account - created <user account id> logAccount.csv

0800200 Notice User account - deleted <user account id> logAccount.csv

0800400 Notice User account - name changed <user account id> logAccount.csv

0800600 Notice User account - password changed logAccount.csv

0800800 Notice User account- password reset <user account id> logAccount.csv

0800A00 Notice User account- unlocked logAccount.csv

0800B00 Notice User account - activated <user account id> logAccount.csv

0800C00 Notice User account - deactivated <user account id> logAccount.csv

0801401 Info User account - Invalid credentials reserved username logAccount.csv

0900D00 Notice <user> connected into interactive CLI with session id XXXXXX logSession.csv

0900E00 Notice <user> disconnected from interactive CLI with session id XXXXXX logSession.csv

0900F00 Notice <user> doesn't have access to CLI - CLI session id XXXXXX logSession.csv

0901000 Notice <user> connected and executes remote command <command> into the CLI - CLI logSession.csv
session id XXXXXX

0901100 Notice <user> finished executing remote command <command> into the CLI - CLI session logSession.csv
id XXXXXX

0901200 Notice <user> connection rejected - CLI session id XXXXXX logSession.csv

0901300 Notice <user> disconnected from interactive CLI with session id XXXXXX due to session logSession.csv
timeout

0901400 Notice <user> disconnected from interactive CLI with session id XXXXXX due to concurrent logSession.csv
connection with session id XXXXXX

0100C00 Notice Syslog is started logSystem.csv

0100B00 Notice Syslog is stopping logSystem.csv

0100D00 Notice Network module is booting logSystem.csv

0100E00 Notice Network module is operating logSystem.csv

0100F00 Notice Network module is starting shutdown sequence logSystem.csv

0101000 Notice Network module is ending shutdown sequence logSystem.csv

Information – 248
List of event codes

0101400 Notice Network module shutdown requested logSystem.csv

0101500 Notice Network module reboot requested logSystem.csv

0101600 Notice Network module reboot rejected logSystem.csv

0100200 Notice <nb alarms> alarms exported and flushed logSystem.csv

0A00100 Info Network module upgrade success <f/w: xx.yy.zzzz> logUpdate.csv

0A00300 Info Network module upgrade started logUpdate.csv

0A00600 Info Network module file system integrity OK <f/w: xx.yy.zzzz> logUpdate.csv

0B00300 Info Time with NTP synchronized logSystem.csv

0B00600 Info Time settings changed logSystem.csv

0B01100 Info Time reset to last known date: "date" logSystem.csv

0C00F00 Info Test email

1000100 Info Settings saving requested logSystem.csv

1000200 Info <feature> settings saved logSystem.csv

1000A00 Info Settings restoration requested logSystem.csv

1000E00 Info <feature> settings restoration success logSystem.csv

1000B00 Info Settings restoration success logSystem.csv

0301500 Notice Sanitization switch changed logSystem.csv

0A01600 Notice Major version downgrade logUpdate.csv

0D00800 Notice DHCP client script called with <script parameters> logSystem.csv

0D00900 Notice IPv4 configuration changed to <ipsv4_address> logSystem.csv

0D01000 Notice IPv6 configuration changed to <ipsv6_address> logSystem.csv

0E00100 Notice Outlet State change logSystem.csv

1200700 Notice Config file has been applied logSystem.csv

Event with code 0700600 is used within shutdown script. The severity may vary according to the event context.

Information – 249
List of event codes

7.5.2 UPS(HID) alarm log codes


This table applies to all UPS except to the 9130 UPS.

To retrieve Alarm logs, navigate to Contextual help>>>Alarms section and press the Download alarms button.

Below codes are the one to be used to add "Exceptions on events notification" on email sending configurations.
Some zeros maybe added in front of the code when displayed in emails or logs.

7.5.2.1 Critical

Code Severity Active message Non-active message Advice

002 Critical Internal failure End of internal failure Service required

004 Critical Temperature alarm Temperature OK Check air conditioner

100 Critical Rectifier fuse fault Rectifier fuse OK Service required

105 Critical Input AC module failure Input AC module OK Service required

207 Critical Bypass AC module failure Bypass AC module OK -

208 Critical Bypass overload No bypass overload -

305 Critical Rectifier failure Rectifier OK Service required

306 Critical Rectifier overload Rectifier OK Reduce output load

308 Critical Rectifier short circuit Rectifier OK Reduce output load

400 Critical DCDC converter failure DCDC converter OK Service required

500 Critical Battery charger fault Battery charger OK Service required

607 Critical Battery test failed Battery test OK Check battery

60D Critical No battery Battery present Check battery

61B Critical Battery BMS fault Battery BMS OK Check battery

629 Critical Battery voltage low critical Battery voltage OK Check battery

62B Critical Battery voltage high critical Battery voltage OK Check battery

62D Critical Battery charge current low critical Battery charge current OK Check battery

62F Critical Battery charge current high critical Battery charge current OK Check battery

631 Critical Battery discharge current low Battery discharge current OK Check battery
critical

633 Critical Battery discharge current high Battery discharge current OK Check battery
critical

Information – 250
List of event codes

635 Critical Battery temperature low critical Battery temperature OK Check battery

637 Critical Battery temperature high critical Battery temperature OK Check battery

63E Critical Battery fault Battery OK Check battery

704 Critical Inverter internal failure UPS OK Service required

705 Critical Inverter overload No power overload Reduce output load

706 Critical Temperature alarm Temperature OK Check air conditioner

70B Critical Inverter short circuit End of inverter short circuit Service required

805 Critical Output short circuit Output OK Reduce output load

811 Critical Parallel negative power Parallel power OK Reduce output load

815 Critical Calibration fault Calibration OK Service required

81E Critical Load unprotected Load protected -

7.5.2.2 Warning

Code Severity Active message Non-active message Advice

001 Warning On battery No more on battery -

007 Warning Fan fault Fan OK Service required

00B Warning Parallel UPS redundancy lost Parallel UPS redundancy OK Reduce output load

00E Warning Parallel UPS communication lost Parallel UPS communication OK Service required

00F Warning Parallel UPS not compatible Parallel UPS compatibility OK Service required

010 Warning UPS power supply fault UPS power supply OK Service required

011 Warning Parallel UPS protection lost Parallel UPS protection OK Reduce output load

012 Warning Parallel UPS measure inconsistent Parallel UPS measure OK Service required

020 Warning On battery On normal mode

021 Warning On bypass On normal mode

022 Warning Alarm signaled No alarm reported -

103 Warning Utility breaker open Utility breaker closed -

104 Warning Input AC frequency out of range Input AC frequency in range -

106 Warning Input AC not present Input AC present -

107 Warning Input bad wiring Input wiring OK Check input wiring

108 Warning Input AC voltage out of range (-) Input AC voltage in range -

109 Warning Input AC voltage out of range (+) Input AC voltage in range -

Information – 251
List of event codes

110 Warning Building alarm (through dry Building alarm OK -


contact)

11F Warning Building alarm (through Network Building alarm OK -


module)

10A Warning Input AC unbalanced End of input AC unbalanced -

200 Warning Bypass phase out range Bypass phase in range -

201 Warning Bypass not available Bypass available Service required

202 Warning Bypass thermal overload Bypass thermal OK Reduce output load

203 Warning Bypass temperature alarm Bypass temperature OK Check air conditioner

204 Warning Bypass breaker open Bypass breaker closed -

205 Warning Bypass mode No more on bypass -

206 Warning Bypass frequency out of range Bypass frequency in range -

209 Warning Bypass voltage out of range Bypass voltage in range -

20A Warning Bypass AC over voltage End of bypass AC over voltage -

20B Warning Bypass AC under voltage End of bypass AC under voltage -

20C Warning Bypass bad wiring Bypass wiring OK Check bypass wiring

300 Warning DC bus + too high DC bus + voltage OK Service required

301 Warning DC bus - too high DC bus - voltage OK Service required

302 Warning DC bus + too low DC bus + voltage OK Service required

303 Warning DC bus - too low DC bus - voltage OK Service required

304 Warning DC bus unbalanced DC bus OK Service required

501 Warning Charger temperature alarm Charger temperature OK Service required

502 Warning Max charger voltage Charger voltage OK Service required

503 Warning Min charger voltage Charger voltage OK Service required

600 Warning Battery fuse fault Battery fuse OK Service required

602 Warning Battery fuse fault Battery fuse OK Service required

604 Warning Battery low state of charge Battery state of charge OK -

605 Warning Battery temperature alarm Battery temperature OK Service required

606 Warning Battery breaker open Battery breaker closed Service required

610 Warning Battery low voltage Battery voltage OK Check battery

613 Warning Battery voltage too high Battery voltage OK Check battery

616 Warning Battery voltage unbalanced Battery voltage OK Check battery

Information – 252
List of event codes

618 Warning Battery voltage too low Battery voltage OK Check battery

61C Warning Communication with battery lost Communication with battery Check battery
recovered

61E Warning At least one breaker in battery is All battery breakers are closed Check battery
open

61F Warning Battery State Of Charge below Battery State Of Charge OK -


limit

620 Warning Battery State Of Health below limit Battery State Of Health OK Check battery

628 Warning Battery voltage low warning Battery voltage OK Check battery

62A Warning Battery voltage high warning Battery voltage OK Check battery

62C Warning Battery charge current low Battery charge current OK Check battery
warning

62E Warning Battery charge current high Battery charge current OK Check battery
warning

630 Warning Battery discharge current low Battery discharge current OK Check battery
warning

632 Warning Battery discharge current high Battery discharge current OK Check battery
warning

634 Warning Battery temperature low warning Battery temperature OK Check battery

636 Warning Battery temperature high warning Battery temperature OK Check battery

638 Warning Battery BMS failure Battery BMS OK Check battery

639 Warning Battery temperature unbalanced Battery temperature OK Check battery

63D Warning Battery warning Battery OK Check battery

700 Warning Inverter limitation No current limitation Reduce output load

701 Warning Inverter fuse fault Inverter fuse OK Service required

70A Warning Inverter thermal overload No power overload Reduce output load

70C Warning Inverter voltage too low Inverter voltage OK Service required

70D Warning Inverter voltage too high Inverter voltage OK Service required

801 Warning Load not powered Load powered -

803 Warning Output breaker open Output breaker closed -

806 Warning Emergency power OFF No emergency OFF -

808 Warning Power overload No power overload Reduce output load

80D Warning Internal configuration failure Internal configuration OK Service required

80E Warning Overload pre-alarm No overload pre-alarm Reduce output load

810 Warning Overload alarm No overload Reduce output load

Information – 253
List of event codes

814 Warning Firmware watchdog reset Firmware watchdog OK Service required

816 Warning Compatibility failure Compatibility OK Service required

817 Warning Output over current No output over current Reduce output load

818 Warning Output frequency out of range Output frequency in range Service required

819 Warning Output voltage too high Output voltage OK Service required

81A Warning Output voltage too low Output voltage OK Service required

81B Warning UPS Shutoff requested End of UPS shutoff requested Service required

81D Warning Load not powered Load protected -

81F Warning Output phase 1 overload Output phase 1 no overload -

820 Warning Output phase 2 overload Output phase 2 no overload -

821 Warning Output phase 3 overload Output phase 3 no overload -

900 Warning Maintenance bypass Not on maintenance bypass -

901 Warning Maintenance bypass breaker Maintenance bypass breaker open -


closed

B01 Warning Batteries are aging. Consider Batteries aging condition cleared -
replacement

7.5.2.3 Info

Code Severity Active message Non-active message Advice

005 Info Communication lost (with UPS) Communication recovered (with Service required
UPS)

013 Info Upgrading: limited communication End of upgrade mode -

01E Info Inactive On normal mode

101 Info On AVR (Boost) End of AVR (Boost) -

102 Info On AVR (Buck) End of AVR (Buck) -

603 Info Battery discharging End of UPS battery discharge -

63C Info Battery information Battery OK -

A00 Info Group 1 is OFF Group 1 is ON -

A01 Info Group 2 is OFF Group 2 is ON -

A0F Info Group is OFF Group is ON -

Information – 254
List of event codes

7.5.2.4 Good
Alarms with a severity set as Good are not taken into account into the counter of active alarms.

Code Severity Active message Non-active message

009 Good On high efficiency / On ESS mode High efficiency disabled / ESS disabled

01F Good Ready On normal mode

60E Good UPS external battery set as “No battery” UPS external battery set as present

826 Good Load powered with no continuity Load protected

Information – 255
List of event codes

7.5.3 UPS(XCP and COPI) alarm log codes


Use this table for 9130, 9x55, 9395P, BladeUPS.

To retrieve Alarm logs, navigate to Contextual help>>>Alarms section and press the Download alarms button.

Below codes are the one to be used to add "Exceptions on events notification" on email sending configurations.
Some zeros maybe added in front of the code when displayed in emails or logs.

7.5.3.1 Critical

Code Severity Active message Non-active message Advice

2002 Critical Inverter AC frequency out of range Inverter AC frequency in range -

2012 Critical Emergency power OFF No emergency OFF -

2020 Critical Bypass temperature alarm Bypass temperature OK -

2022 Critical Charger power supply tripped Charger power supply no longer -
tripped

2024 Critical Inverter Temperature too high Inverter Temperature OK -

2026 Critical Rectifier current too high Rectifier OK -

2030 Critical Rectifier failure Rectifier current OK -

2031 Critical Inverter internal failure UPS OK -

2032 Critical Battery breaker failure Battery breaker OK -

2033 Critical Automatic bypass breaker failure Automatic bypass breaker OK -

2034 Critical Battery charger fault Battery charger OK -

2036 Critical Bypass AC static switch failure Bypass AC static switch OK -

2246 Critical Neutral current limitation Neutral current OK -

2048 Critical Inverter Start failure Inverter Start OK -

2051 Critical Battery ground fault Battery ground OK -

2053 Critical Non volatile memory failure Non volatile memory OK -

2055 Critical UPS shutdown imminent UPS shutdown no longer imminent -

2056 Critical Battery low state of charge Battery state of charge OK -

2058 Critical Output short circuit Output OK -

2064 Critical Rectifier self test failed Rectifier self test OK -

2068 Critical Battery voltage too high Battery voltage OK -

Information – 256
List of event codes

2070 Critical UPS power supply fault UPS power supply OK -

2073 Critical Temperature too high Temperature OK -

2075 Critical Rectifier overload Rectifier OK -

2076 Critical Rectifier Offline due to Rectifier no longer tripped -


overtemperature

2077 Critical Input AC module failure Input AC module OK -

2079 Critical Inverter self test failed Inverter self test OK -

2089 Critical Output voltage DC offset too high Output voltage DC offset OK -

2111 Critical Inverter Offline due to Inverter no longer tripped -


overtemperature

2112 Critical DC/DC converter failure DC/DC converter OK -

2116 Critical Charger voltage too low Charger voltage OK -

2126 Critical Battery totally discharged Battery no longer totally discharged -

2133 Critical Loss of Sync bus Sync bus recovered -

2149 Critical Battery needs service Battery OK -

2157 Critical Output breaker failure Output breaker OK -

2165 Critical Output phase 1 extreme overload Output phase 1 no extreme -


overload

2166 Critical Output phase 2 extreme overload Output phase 2 no extreme -


overload

2167 Critical Output phase 3 extreme overload Output phase 3 no extreme -


overload

2177 Critical Inverter Temperature sensor failed Inverter Temperature sensor OK -

2186 Critical Emergency transfer to bypass Back from bypass -

2188 Critical Bypass AC module failure Bypass AC module OK -

2191 Critical Battery fault Battery OK Check battery

2192 Critical Fuse fault Fuse OK -

2193 Critical Fan fault Fan OK -

2195 Critical Backfeed bypass contactor failure Backfeed bypass contactor OK -

2199 Critical Battery not present Battery present Check battery

2200 Critical Temperature out of range Temperature in range -

2201 Critical Transformer Temperature too high Transformer Temperature OK -

2217 Critical Utility input breaker failure Utility input breaker OK -

2220 Critical UPS module taken out of parallel UPS module back on parallel -
system system

Information – 257
List of event codes

2221 Critical Inverter output failure Inverter output OK -

2223 Critical Rectifier over temperature Rectifier temperature OK -

2229 Critical At least one critical alarm active No critical alarm active -

2238 Critical Inverter phases out of sequence Inverter phases wired OK -

2240 Critical External CAN network fault External CAN network OK -

2242 Critical Inverter breaker failure Inverter breaker OK -

2249 Critical Rectifier over temperature tripped Rectifier temperature OK -

2259 Critical Rectifier short circuit Rectifier OK -

2260 Critical Rectifier short circuit Rectifier OK -

2261 Critical Rectifier short circuit Rectifier OK -

2323 Critical Inverter overload No power overload -

2324 Critical Inverter short circuit End of inverter short circuit -

2325 Critical Bypass overload No bypass overload -

2328 Critical Bypass thermal overload Bypass thermal OK -

2364 Critical Internal failure End of internal failure -

2365 Critical Ground fault Ground OK -

2380 Critical Output phase 1 excessive overload Output phase 1 no excessive -


overload

2381 Critical Output phase 2 excessive overload Output phase 2 no excessive -


overload

2382 Critical Output phase 3 excessive overload Output phase 3 no excessive -


overload

2386 Critical Major alarm condition that makes the No longer major alarm condition -
device need service that makes the device need service

2387 Critical Battery voltage low Battery voltage no longer low -

2392 Critical Automatic bypass static switch current Automatic bypass static switch -
too high current OK

2402 Critical Parallel UPS not compatible Parallel UPS compatibility OK -

7.5.3.2 Warning

Code Severity Active message Non-active message Advice

2000 Warning Inverter voltage too high Inverter voltage OK -

2001 Warning Inverter voltage too low Inverter voltage OK -

Information – 258
List of event codes

2003 Warning Bypass AC over voltage End of bypass AC over voltage -

2004 Warning Bypass AC under voltage No Bypass AC under voltage -

2005 Warning Bypass frequency out of range Bypass frequency in range -

2006 Warning Input AC voltage out of range (+) Input AC voltage in range -

2007 Warning Input AC voltage out of range (-) Input AC voltage in range -

2008 Warning Input AC frequency out of range Input AC frequency in range -

2009 Warning Output voltage too high Output voltage OK -

2010 Warning Output voltage too low Output voltage OK -

2011 Warning Output frequency out of range Output frequency in range -

2012 Warning Emergency power OFF No emergency OFF -

2021 Warning Charger over temperature Charger temperature OK -

2023 Warning Charger over voltage or current Charger voltage or current OK -

2025 Warning Power overload No power overload -

2027 Warning Inverter output current too high Inverter output current OK -

2028 Warning DC bus voltage too high DC bus voltage OK -

2029 Warning DC bus voltage too low DC bus voltage OK -

2047 Warning Battery discharge current too high Battery discharge current OK -

2056 Warning Battery voltage or energy too low Battery voltage or energy OK -

2057 Warning On battery No more on battery -

2063 Warning Internal communication failure Internal communication OK -

2067 Warning Input AC not present Input AC present -

2075 Warning Rectifier input or output over Rectifier current OK -


current

2102 Warning Inverter L1 current too high Inverter L1 current OK -

2103 Warning Inverter L2 current too high Inverter L2 current OK -

2104 Warning Inverter L3 current too high Inverter L3 current OK -

2105 Warning Bypass available Bypass not available -

2106 Warning Utility input breaker closed Utility input breaker open -

2107 Warning Battery breaker open Battery breaker closed -

2108 Warning Inverter breaker open Inverter breaker closed -

2109 Warning Automatic bypass breaker open Automatic bypass breaker closed -

2112 Warning DC/DC converter failure DC/DC converter OK -

Information – 259
List of event codes

2118 Warning Input phases out of sequence Input phases wired OK -

2119 Warning Bypass phases out of sequence Bypass phases wired OK -

2132 Warning Parallel UPS redundancy lost Parallel UPS redundancy OK -

2137 Warning Output breaker open Output breaker closed -

2142 Warning Bypass source power not Bypass source power OK -


sufficient

2143 Warning On maintenance bypass No more on maintenance bypass -

2147 Warning Firmware watchdog reset Firmware watchdog OK -

2159 Warning Output phase 1 overload pre-alarm Output phase 1 no overload pre-alarm -

2160 Warning Output phase 2 overload pre-alarm Output phase 2 no overload pre-alarm -

2161 Warning Output phase 3 overload pre-alarm Output phase 3 no overload pre-alarm -

2162 Warning Output phase 1 overload Output phase 1 no overload -

2163 Warning Output phase 2 overload Output phase 2 no overload -

2164 Warning Output phase 3 overload Output phase 3 no overload -

2168 Warning Battery discharging Battery no longer discharging -

2169 Warning On bypass No longer on bypass -

2170 Warning Load not powered Load powered -

2176 Warning Compatibility failure Compatibility OK -

2189 Warning Load not powered Load powered -

2194 Warning Input bad wiring Input wiring OK -

2206 Warning UPS Shutdown requested End of UPS shutdown requested -

2203 Warning Ambient temperature is too high Ambient temperature is Ok -

2208 Warning Charger unable to charge battery Charger can charge battery -

2210 Warning UPS startup pending UPS startup no longer pending -

2224 Warning Internal configuration failure Internal configuration OK -

2231 Warning DC bus unbalanced DC bus OK -

2243 Warning Output watt overload No more output watt overload -

2248 Warning Input AC on generator Input AC not on generator -

2253 Warning Moment Static Switch open Moment Static Switch closed -

2259 Warning Rectifier L1 current too high Rectifier L1 current OK -

2260 Warning Rectifier L2 current too high Rectifier L2 current OK -

2261 Warning Rectifier L3 current too high Rectifier L3 current OK -

Information – 260
List of event codes

2306 Warning Bypass breaker open Bypass breaker closed -

2309 Warning Output phases are rotated Output phases wired OK -

2322 Warning Battery temperature too high Battery temperature OK -

2326 Warning Bypass phase out range Bypass phase in range -

2327 Warning Bypass voltage out of range Bypass voltage in range -

2342 Warning Overload pre-alarm No overload pre-alarm -

2364 Warning Internal failure End of internal failure -

2366 Warning Bypass bad wiring Bypass wiring OK -

2369 Warning Battery low state of charge Battery state of charge OK -

2384 Warning Major alarm condition that makes No longer major alarm condition that -
the device fail makes the device fail

2395 Warning Bypass frequency out of sync Bypass frequency no longer out of sync -

2396 Warning Input frequency out of sync Input frequency no longer out of sync -

2397 Warning Output frequency out of sync Output frequency no longer out of sync -

7.5.3.3 Info

Code Severity Active message Non-active message Advice

2014 Info Building alarm 6 No building alarm 6 -

2015 Info Building alarm 5 No building alarm 5 -

2016 Info Building alarm 4 No building alarm 4 -

2017 Info Building alarm 3 No building alarm 3 -

2018 Info Building alarm 2 No building alarm 2 -

2019 Info Building alarm 1 No building alarm 1 -

2038 Info Bypass AC sensor not Bypass AC sensor OK -


calibrated

2039 Info Input AC sensor not calibrated Input AC sensor calibrated -

2040 Info Output AC sensor not Output AC sensor calibrated -


calibrated

2041 Info Inverter sensor not calibrated Inverter sensor calibrated -

2042 Info DC bus sensor not calibrated DC bus sensor calibrated -

2043 Info Output AC current sensor not Output AC current sensor calibrated -
calibrated

Information – 261
List of event codes

2044 Info Input AC current sensor not Input AC current sensor calibrated -
calibrated

2045 Info Battery current sensor not Battery current sensor calibrated -
calibrated

2059 Info Utility AC not present Utility AC present -

2063 Info Internal communication failure Internal communication OK -

2121 Info Parallel UPS internal failure Parallel UPS OK -

2130 Info Charger current too high Charger current OK -

2135 Info Charger not synchronized with Charger synchronized with input phase -
input phase

2168 Info Battery discharging UPS battery no longer discharging -

2185 Info Automatic bypass breaker Automatic bypass breaker closed -


should be closed

2196 Info On AVR (Buck) End of AVR (Buck) -

2197 Info On AVR (Boost) End of AVR (Boost) -

2202 Info Ambient temperature is too Ambient temperature is OK -


Low

2204 Info Door or cover of the UPS open Door or cover of the UPS closed -

2211 Info Modem connection fault Modem connection OK -

2227 Info On high efficiency or ESS No longer on High efficiency or ESS -

2228 Info At least one informational alarm No informational alarms active -


active

2247 Info Battery breaker should be Battery breaker closed -


closed

2370 Info Building alarm 7 Building alarm 7 OK -

2371 Info Building alarm 8 Building alarm 8 OK -

2372 Info Building alarm 9 Building alarm 9 OK -

2383 Info Condition in the device to call No longer condition in the device to call -
user user

2385 Info Service scheduled Service no longer scheduled -

Information – 262
List of event codes

7.5.4 ATS alarm log codes


To retrieve Alarm logs, navigate to Contextual help>>>Alarms section and press the Download alarms button.

Below codes are the one to be used to add "Exceptions on events notification" on email sending configurations.
Some zeros maybe added in front of the code when displayed in emails or logs.

7.5.4.1 Critical

Code Severity Active message Non-active message Advice

F03 Critical Internal failure End of internal failure -

F08 Critical Internal failure End of internal failure -

F0B Critical Internal failure End of internal failure -

F0D Critical In short circuit Not in short circuit -

F10 Critical Load not powered Load powered with no continuity -

F11 Critical Internal failure End of internal failure -

F13 Critical Temperature out of range Temperature in range -

F1B Critical Off On preferred source -

7.5.4.2 Warning

Code Severity Active message Non-active message Advice

F00 Warning Unsynchronized sources Synchronized sources -

F01 Warning Frequency out of range Frequency in range -

F02 Warning Out of range In range -

F04 Warning Voltage in derated range Voltage in normal range -

F06 Warning Frequency out of range Frequency in range -

F07 Warning Not in range In range -

F09 Warning Voltage in derated range Voltage in normal range -

F0C Warning In overload Not in overload -

F0F Warning Internal configuration failure Internal configuration OK -

F12 Warning Overload Fault No overload fault -

F15 Warning Input waveform is not OK Input waveform is OK -

Information – 263
List of event codes

F16 Warning Voltage out of range Voltage in range -

F17 Warning Input waveform is not OK Input waveform is OK -

F18 Warning Voltage out of range Voltage in range -

F1A Warning On alternate source - -

7.5.4.3 Good
Alarms with a severity set as Good are not taken into account into the counter of active alarms.

Code Severity Active message Non-active message Advice

F05 Good Source 1 used to power the load Source 1 not used to power the load -

F0A Good Source 2 used to power the load Source 2 not used to power the load -

F19 Good On preferred source - -

Information – 264
List of event codes

7.5.5 EMP alarm log codes


To retrieve Alarm logs, navigate to Contextual help>>>Alarms section and press the Download alarms button.

Below codes are the one to be used to add "Exceptions on events notification" on email sending configurations.
Some zeros maybe added in front of the code when displayed in emails or logs.

7.5.5.1 Critical

Code Severity Active message Non-active message Advice

1201 Critical Temperature is critically low Temperature is back to low -

1204 Critical Temperature is critically high Temperature is back to high -

1211 Critical Humidity is critically low Humidity is back to low -

1214 Critical Humidity is critically high Humidity is back to high -

7.5.5.2 Warning

Code Severity Active message Non-active message Advice

1200 Warning Communication lost Communication recovered -

1202 Warning Temperature is low Temperature is back to normal -

1203 Warning Temperature is high Temperature is back to normal -

1212 Warning Humidity is low Humidity is back to normal -

1213 Warning Humidity is high Humidity is back to normal -

7.5.5.3 With settable severity

Code Severity Active message Non-active message Advice

1221 Settable Contact is active Contact is back to normal -

Information – 265
List of event codes

7.5.6 Network module alarm log codes


To retrieve Alarm logs, navigate to Contextual help>>>Alarms section and press the Download alarms button.

Below codes are the one to be used to add "Exceptions on events notification" on email sending configurations.
Some zeros maybe added in front of the code when displayed in emails or logs.

7.5.6.1 Warning

7.5.6.1.1 Protection

Code Severity Active message Non-active message Advice

1032 Warning Protection: immediate shutdown in progress Protection: immediate shutdown completed -

1053 Warning Protection: communication lost with agent Protection: communication recovered with agent -

7.5.6.1.2 Alarms

Code Severity Active message Non-active message Advice

1303 Warning Alarms: the number of alarms is too Alarms: the number of alarms is 2 000 alarms have been
high and above 6 000 back to normal erased and saved in a
backup file.

7.5.6.2 Info

7.5.6.2.1 Protection

Code Severity Active message Non-active message Advice

1016 Info Protection: sequential shutdown scheduled Protection: sequential shutdown canceled -

1017 Info Protection: sequential shutdown in progress Protection: sequential shutdown completed -

1054 Info Protection: agent is in unknown state Protection: agent is in service -

1055 Info Protection: agent is starting Protection: agent is in service -

1056 Info Protection: agent is stopping Protection: agent is in service -

1057 Info Protection: agent is stopped Protection: agent is in service -

1100 Info Schedule: shutdown date reached Schedule: shutdown initiated -

Information – 266
SNMP traps

7.5.6.2.2 Communication

Code Severity Active message Non-active message Advice

1300 Info Communication: No device connected Communication: Communication with the device is back -

1301 Info Communication: Device not supported Communication: Communication with the device is back -

7.5.6.2.3 Alarms

Code Severity Active message Non-active message Advice

1302 Info Alarms: the number of alarms is Alarms: the number of alarms is It is recommended to
high and above 5 000 back to normal Export and Clear the alarm
log.

7.6 SNMP traps

7.6.1 UPS Mib

7.6.1.1 IETF Mib-2 Ups traps


This information is for reference only.

Trap oid : Description :


.1.3.6.1.2.1.33.2.0.x

.1.3.6.1.2.1.33.2.0.1 Sent whenever the UPS transfers on battery,


then sent every minutes until the UPS Comes back to AC Input.

.1.3.6.1.2.1.33.2.0.3 Sent whenever an alarm appears.


The matching alarm oid is added as bound variables in the table below.

.1.3.6.1.2.1.33.2.0.4 Sent whenever an alarm disappears.


The matching alarm oid is added as bound variables in the table below.

Alarm oid at : Description when trap 3 Description when trap 4


.1.3.6.1.2.1.33.1.6.3.x

.1.3.6.1.2.1.33.1.6.3.1 Battery test failed Battery test OK

.1.3.6.1.2.1.33.1.6.3.2 Battery discharging End of UPS battery discharge

.1.3.6.1.2.1.33.1.6.3.3 Low battery Battery OK

.1.3.6.1.2.1.33.1.6.3.5 Temperature alarm Temperature OK

.1.3.6.1.2.1.33.1.6.3.6 Input AC not present Input AC present

Information – 267
SNMP traps

Alarm oid at : Description when trap 3 Description when trap 4


.1.3.6.1.2.1.33.1.6.3.x

.1.3.6.1.2.1.33.1.6.3.8 Power overload No power overload

.1.3.6.1.2.1.33.1.6.3.9 Bypass mode No more on bypass

.1.3.6.1.2.1.33.1.6.3.10 Bypass not available Bypass available

.1.3.6.1.2.1.33.1.6.3.13 Battery charger fault Battery charger OK

.1.3.6.1.2.1.33.1.6.3.14 Not powered Powered (Protected or Not protected)

.1.3.6.1.2.1.33.1.6.3.16 Fan fault Fan OK

.1.3.6.1.2.1.33.1.6.3.17 Battery fuse fault Battery fuse OK


Rectifier fuse fault Rectifier fuse OK
Inverter fuse fault Inverter fuse OK

.1.3.6.1.2.1.33.1.6.3.18 Internal failure End of internal failure

.1.3.6.1.2.1.33.1.6.3.20 Communication lost Communication recovered

.1.3.6.1.2.1.33.1.6.3.23 Shutdown imminent Shutdown canceled

7.6.1.2 Xups Mib traps


This information is for reference only.

Trap oid : Trap message at Code HID (For UPS 5P, 5PX, 9SX, Code XCP (For UPS Blade,
oid : 9PX, 9xPM, 9xE, 9xPS) 9395, 9395P, 9395C, 9x55)
.1.3.6.1.4.1.534.1.11
.4.1.0.x .1.3.6.1.4.1.534.1.1
1.3.0

.1.3.6.1.4.1.534.1.11 Battery discharging 603 2168


.4.1.0.3

.1.3.6.1.4.1.534.1.11 Battery low 604 2056, 2369, 2387


.4.1.0.4

.1.3.6.1.4.1.534.1.11 No more on battery 104, 106 2067


.4.1.0.5

.1.3.6.1.4.1.534.1.11 Battery OK 604 2056, 2369, 2387


.4.1.0.6

.1.3.6.1.4.1.534.1.11 Power overload 208, 306, 705, 80E, 810, 81f, 820, 2102, 2103, 2104, 2325, 2027,
.4.1.0.7 821, 808 2025, 2159, 2160, 2162, 2163,
2164, 2165, 2166, 2167, 2323,
2342, 2380, 2381, 2382

.1.3.6.1.4.1.534.1.11 Internal failure 002, 010, 105, 300, 301, 302, 2000, 2001, 2047, 2051, 2063,
.4.1.0.8 303, 305, 400, 621, 80d, 814, 2070, 2077, 2089, 2135, 2147,
816 2224, 2229, 2365, 2384, 2364,
2002, 2026, 2028, 2029, 2112,
2031, 2048, 2068

.1.3.6.1.4.1.534.1.11 Battery totally 2126


.4.1.0.9 discharged

.1.3.6.1.4.1.534.1.11 Inverter internal 704 2031


.4.1.0.10 failure

Information – 268
SNMP traps

Trap oid : Trap message at Code HID (For UPS 5P, 5PX, 9SX, Code XCP (For UPS Blade,
oid : 9PX, 9xPM, 9xE, 9xPS) 9395, 9395P, 9395C, 9x55)
.1.3.6.1.4.1.534.1.11
.4.1.0.x .1.3.6.1.4.1.534.1.1
1.3.0

.1.3.6.1.4.1.534.1.11 Bypass mode 205 2169


.4.1.0.11

.1.3.6.1.4.1.534.1.11 Bypass not available 201 2105, 2003, 2004, 2142, 2005
.4.1.0.12

.1.3.6.1.4.1.534.1.11 Load not powered 819, 81A, 818, 81D 2170


.4.1.0.13

.1.3.6.1.4.1.534.1.11 On battery 104, 106 2067, 2006, 2007, 2008, 2059


.4.1.0.14

.1.3.6.1.4.1.534.1.11 Building alarm 110 2014, 2015, 2016, 2017, 2018,


.4.1.0.15 through input dry 2019, 2370, 2371, 2372
contact

.1.3.6.1.4.1.534.1.11 Shutdown 2055


.4.1.0.16 imminent

.1.3.6.1.4.1.534.1.11 No more on bypass 205


.4.1.0.17

.1.3.6.1.4.1.534.1.11 Breaker open 103, 204, 606 2106, 2107, 2108, 2109, 2137,
.4.1.0.20 2251, 2252, 2254, 2255, 2252

.1.3.6.1.4.1.534.1.11 Battery test failed 607, 61B 2149, 2191, 2247


.4.1.0.23

.1.3.6.1.4.1.534.1.11 Diagnostic test 2053, 2064, 2079, 2176


.4.1.0.25 failed

.1.3.6.1.4.1.534.1.11 Communication lost 005


.4.1.0.26

.1.3.6.1.4.1.534.1.11 Sensor contact is


.4.1.0.30 active

.1.3.6.1.4.1.534.1.11 Sensor contact back


.4.1.0.31 to normal

.1.3.6.1.4.1.534.1.11 Parallel UPS 00B 2132


.4.1.0.32 redundancy lost

.1.3.6.1.4.1.534.1.11 Temperature alarm 004, 203, 501, 605, 706 1201, 1204, 2202, 2203, 2200,
.4.1.0.33 2020, 2021, 2024, 2073, 2111,
2201, 2223, 2249

.1.3.6.1.4.1.534.1.11 Battery charger 500 2030, 2022, 2034, 2075, 2076,


.4.1.0.34 fault 2208, 2259, 2260, 2261

.1.3.6.1.4.1.534.1.11 Fan fault 007 2193


.4.1.0.35

.1.3.6.1.4.1.534.1.11 Fuse fault 100, 600, 602, 701 2192


.4.1.0.36

.1.3.6.1.4.1.534.1.11 Sensor temperature


.4.1.0.42 is below/above
critical threshold

Information – 269
SNMP traps

Trap oid : Trap message at Code HID (For UPS 5P, 5PX, 9SX, Code XCP (For UPS Blade,
oid : 9PX, 9xPM, 9xE, 9xPS) 9395, 9395P, 9395C, 9x55)
.1.3.6.1.4.1.534.1.11
.4.1.0.x .1.3.6.1.4.1.534.1.1
1.3.0

.1.3.6.1.4.1.534.1.11 Sensor humidity is


.4.1.0.43 below/above critical
threshold

.1.3.6.1.4.1.534.1.11 Maintenance 900 2143


.4.1.0.48 bypass

.1.3.6.1.4.1.534.1.11 Charger voltage 502, 503 2023, 2116


.4.1.0.52 alarm

.1.3.6.1.4.1.534.1.11 Short circuit 308, 629, 70B, 805


.4.1.0.53

7.6.2 ATS Mib


This information is for reference only.

Trap oid : Trap description


.1.3.6.1.4.1.534.10.2.10.x

.1.3.6.1.4.1.534.10.2.10.1 Communication lost

.1.3.6.1.4.1.534.10.2.10.2 Communication recovered

.1.3.6.1.4.1.534.10.2.10.3 Output powered

.1.3.6.1.4.1.534.10.2.10.4 Output not powered

.1.3.6.1.4.1.534.10.2.10.5 Overload

.1.3.6.1.4.1.534.10.2.10.6 No overload

.1.3.6.1.4.1.534.10.2.10.7 Internal failure

.1.3.6.1.4.1.534.10.2.10.8 No internal failure

.1.3.6.1.4.1.534.10.2.10.9 Source 1 normal

.1.3.6.1.4.1.534.10.2.10.10 Source 1 out of range

.1.3.6.1.4.1.534.10.2.10.11 Source 2 normal

.1.3.6.1.4.1.534.10.2.10.12 Source 2 out of range

.1.3.6.1.4.1.534.10.2.10.13 Sources desynchronized

.1.3.6.1.4.1.534.10.2.10.14 Sources synchronized

.1.3.6.1.4.1.534.10.2.10.15 Output powered by source 1

.1.3.6.1.4.1.534.10.2.10.16 Output powered by source 2

.1.3.6.1.4.1.534.10.2.10.20 Remote temperature low

.1.3.6.1.4.1.534.10.2.10.21 Remote temperature high

Information – 270
CLI

Trap oid : Trap description


.1.3.6.1.4.1.534.10.2.10.x

.1.3.6.1.4.1.534.10.2.10.22 Remote temperature normal

.1.3.6.1.4.1.534.10.2.10.23 Remote humidity low

.1.3.6.1.4.1.534.10.2.10.24 Remote humidity high

.1.3.6.1.4.1.534.10.2.10.25 Remote humidity normal

.1.3.6.1.4.1.534.10.2.10.26 Contact 1 active

.1.3.6.1.4.1.534.10.2.10.27 Contact 1 inactive

.1.3.6.1.4.1.534.10.2.10.28 Contact 2 active

.1.3.6.1.4.1.534.10.2.10.29 Contact 2 inactive

7.6.3 Sensor Mib

7.6.3.1 Sensor Mib traps


This information is for reference only.

Trap oid : Trap description


.1.3.6.1.4.1.534.6.8.1.x.x.x

.1.3.6.1.4.1.534.6.8.1.1.0.1 Sent whenever the sensor count changes after a discovery or removing from the UI.

.1.3.6.1.4.1.534.6.8.1.1.0.2 Sent whenever one status of each sensor connected changes.

.1.3.6.1.4.1.534.6.8.1.2.0.1 Sent whenever one status of each temperature changes.

.1.3.6.1.4.1.534.6.8.1.3.0.1 Sent whenever one status of each humidity changes.

.1.3.6.1.4.1.534.6.8.1.4.0.1 Sent whenever one status of each digital input alarm changes.

7.7 CLI
CLI can be accessed through:
• SSH
• Serial terminal emulation (refer to section Servicing the Network Management Module>>>Installing the Network
Module>>>Accessing the card through serial terminal emulation).
It is intended mainly for automated configuration of the network and time settings of the network card. It can also be used for
troubleshooting and remote reboot/reset of the network interface in case the web user interface is not accessible.
Warning: Changing network parameters may cause the card to become unavailable remotely. If this happens it can only be
reconfigured locally through USB.

7.7.1 Commands available


You can see this list anytime by typing in the CLI:

Information – 271
CLI

7.7.2 Contextual help


You can see this help anytime by typing in the CLI:

help

CONTEXT SENSITIVE HELP


[?] - Display context sensitive help. This is either a list of possible
command completions with summaries, or the full syntax of the
current command. A subsequent repeat of this key, when a command
has been resolved, will display a detailed reference.

AUTO-COMPLETION
The following keys both perform auto-completion for the current command line.
If the command prefix is not unique then the bell will ring and a subsequent
repeat of the key will display possible completions.

[enter] - Auto-completes, syntax-checks then executes a command. If there is


a syntax error then offending part of the command line will be
highlighted and explained.

[space] - Auto-completes, or if the command is already resolved inserts a space.

MOVEMENT KEYS
[CTRL-A] - Move to the start of the line
[CTRL-E] - Move to the end of the line.
[up] - Move to the previous command line held in history.
[down] - Move to the next command line held in history.
[left] - Move the insertion point left one character.
[right] - Move the insertion point right one character.

DELETION KEYS
[CTRL-C] - Delete and abort the current line
[CTRL-D] - Delete the character to the right on the insertion point.
[CTRL-K] - Delete all the characters to the right of the insertion point.
[CTRL-U] - Delete the whole line.
[backspace] - Delete the character to the left of the insertion point.

ESCAPE SEQUENCES
!! - Substitute the last command line.
!N - Substitute the Nth command line (absolute as per 'history' command)
!-N - Substitute the command line entered N lines before (relative)

7.7.3 get release info

7.7.3.1 Description
Displays certain basic information related to the firmware release.

7.7.3.2 Help

get_release_info
-d Get current release date

Information – 272
CLI

-s Get current release sha1


-t Get current release time
-v Get current release version number

7.7.3.3 Specifics

7.7.3.4 Access rights per profiles


Administrator Operator Viewer

get release info

7.7.4 history

7.7.4.1 Description
Displays recent commands executed on the card.

7.7.4.2 Help

history
<cr> Display the current session's command line history(by default display
last 10 commands)
<Unsigned integer> Set the size of history list (zero means unbounded). Example 'history
6' display the 6 last command

7.7.4.3 Specifics

7.7.4.4 Access rights per profiles


Administrator Operator Viewer

history

7.7.5 logout

7.7.5.1 Description
Logout the current user.

7.7.5.2 Help

logout
<cr> logout the user

Information – 273
CLI

7.7.5.3 Specifics

7.7.5.4 Access rights per profiles


Administrator Operator Viewer

logout

7.7.6 maintenance

7.7.6.1 Description
Creates a maintenance report file which may be handed to the technical support.

7.7.6.2 Help

maintenance
<cr> Create maintenance report file.
-h, --help Display help page

7.7.6.3 Examples of usage


Generate the maintenance report by running the "maintenance" command.
Then retrieve the report from the card using SCP

7.7.6.3.1 From a linux host:


sshpass -p $PASSWORD scp $USER@$CARD_ADDRESS:report.zip .

7.7.6.3.2 From a Windows host:


pscp -scp -pw $PASSWORD $USER@$CARD_ADDRESS:report.zip report.zip
(Require pscp tools from putty)
Where:
• $USER is user name (the user shall have administrator profile)
• $PASSWORD is the user password
• $CARD_ADDRESS is IP or hostname of the card

7.7.6.4 Specifics

7.7.6.5 Access rights per profiles


Administrator Operator Viewer

maintenance

Information – 274
CLI

7.7.7 modbus_message_display
This section is only for the Modbus Network Module

7.7.7.1 Description
modbus_message_display restarts the server and displays Modbus message. This command allow you to verifiy that Modbus
server is working as expected.

7.7.7.2 Help

modbus_message_display
--help Restart server and display modbus message
-h Restart server and display modbus message

7.7.7.3 Specifics

7.7.7.4 Access rights per profiles


Administrator Operator Viewer

modbus_message_display*

*for only

7.7.8 modbus_statistics

This section is only for the Modbus Network Module

7.7.8.1 Description
modbus_statistics displays Modbus RTU and TCP status and server statistics:
• Bus character overrun count
• Bus frame error count
• Bus parity error count
• Buffer overrun count

• Bus message count


• Valid message count
• CRC error count
• Incoming message count
• Discarded message count
• Processed message count
• Success returned count
• Exception returned count

Information – 275
CLI

7.7.8.2 Help

modbus_statistics
Display modbus server statistics

-h, --help Display the help page.


-r, --reset Reset modbus server statistics.
The counter from A1.1 to A1.4 are reset only at startup of the
server.

7.7.8.3 Specifics

7.7.8.4 Access rights per profiles


Administrator Operator Viewer

modbus_statistics*

*for only

7.7.9 netconf

7.7.9.1 Description
Tools to display or change the network configuration of the card.

7.7.9.2 Help
For Viewer and Operator profiles:

netconf -h
Usage: netconf [OPTION]...
Display network information and change configuration.

-h, --help display help page


-l, --lan display Link status and MAC address
-4, --ipv4 display IPv4 Mode, Address, Netmask and Gateway
-6, --ipv6 display IPv6 Mode, Addresses and Gateway
-d, --domain display Domain mode, FQDN, Primary and Secondary DNS

For Administrator profile:

netconf -h
Usage: netconf [OPTION]...
Display network information and change configuration.
-h, --help display help page
-l, --lan display Link status and MAC address
-d, --domain display Domain mode, FQDN, Primary and Secondary DNS
-4, --ipv4 display IPv4 Mode, Address, Netmask and Gateway

Information – 276
CLI

-6, --ipv6 display IPv6 Mode, Addresses and Gateway


Set commands are used to modify the settings.
-s, --set-lan <link speed>
Link speed values:
auto Auto negotiation
10hf 10 Mbps - Half duplex
10ff 10 Mbps - Full duplex
100hf 100 Mbps - Half duplex
100ff 100 Mbps - Full duplex
1000ff 1.0 Gbps - Full duplex
-f, --set-domain hostname <hostname> set custom hostname
-f, --set-domain <mode>
Mode values:
- set custom Network address, Netmask and Gateway:
manual <domain name> <primary DNS> <secondary DNS>
- automatically set Domain name, Primary and Secondary DNS
dhcp
-i, --set-ipv4 <mode>
Mode values:
- set custom Network address, Netmask and Gateway
manual <network> <mask> <gateway>
- automatically set Network address, Netmask and Gateway
dhcp
-x, --set-ipv6 <status>
Status values:
- enable IPv6
enable
- disable IPv6
disable
-x, --set-ipv6 <mode>
Mode values:
- set custom Network address, Prefix and Gateway
manual <network> <prefix> <gateway>
- automatically set Network address, Prefix and Gateway
router
Examples of usage:
-> Display Link status and MAC address
netconf -l
-> Set Auto negotiation to Link
netconf --set-lan auto
-> Set custom hostname
netconf --set-domain hostname ups-00-00-00-00-00-00
-> Set Adress, Netmask and Gateway
netconf --set-ipv4 manual 192.168.0.1 255.255.255.0 192.168.0.2
-> Disable IPv6

7.7.9.3 Examples of usage

-> Display Link status and MAC address


netconf -l
-> Set Auto negotiation to Link
netconf -s auto
-> Set custom hostname
netconf -f hostname ups-00-00-00-00-00-00
-> Set Adress, Netmask and Gateway
netconf -i manual 192.168.0.1 255.255.255.0 192.168.0.2

Information – 277
CLI

-> Disable IPv6


netconf -6 disable

7.7.9.4 Specifics

7.7.9.5 Access rights per profiles


Administrator Operator Viewer

netconf (read-only) (read-only)

7.7.10 ping and ping6

7.7.10.1 Description
Ping and ping6 utilities are used to test network connection.

7.7.10.2 Help

ping
The ping utility uses the ICMP protocol's mandatory ECHO_REQUEST datagram
to elicit an ICMP ECHO_RESPONSE from a host or gateway. ECHO_REQUEST
datagrams (``pings'') have an IP and ICMP header, followed by a ``struct
timeval'' and then an arbitrary number of ``pad'' bytes used to fill out
the packet.

-c Specify the number of echo requests to be sent


-h Specify maximum number of hops
<Hostname or IP> Host name or IP address

ping6
The ping6 utility uses the ICMP protocol's mandatory ECHO_REQUEST datagram
to elicit an ICMP ECHO_RESPONSE from a host or gateway. ECHO_REQUEST
datagrams (``pings'') have an IP and ICMP header, followed by a ``struct
timeval'' and then an arbitrary number of ``pad'' bytes used to fill out
the packet.

-c Specify the number of echo requests to be sent


<IPv6 address> IPv6 address

7.7.10.3 Specifics

7.7.10.4 Access rights per profiles


Administrator Operator Viewer

ping

ping6

Information – 278
CLI

7.7.11 reboot

7.7.11.1 Description
Tool to Reboot the card.

7.7.11.2 Help

Usage: reboot [OPTION]


<cr> Reboot the card
--help Display help
--withoutconfirmation Reboot the card without confirmation

7.7.11.3 Specifics

7.7.11.4 Access rights per profiles


Administrator Operator Viewer

reboot

7.7.12 save_configuration | restore_configuration

7.7.12.1 Description
Save_configuration and restore_configuration are using JSON format to save and restore certain part of the configuration of the
card.

7.7.12.2 Help

save_configuration -h
save_configuration: print the card configuration in JSON format to standard output.

restore_configuration -h
restore_configuration: restore the card configuration from a JSON-formatted standard input.

7.7.12.3 Examples of usage

7.7.12.3.1 From a linux host:


Save over SSH: sshpass -p $PASSWORD ssh $USER@$CARD_ADDRESS save_configuration -p $PASSPHRASE> $FILE
Restore over SSH: cat $FILE | sshpass -p $PASSWORD ssh $USER@$CARD_ADDRESS restore_configuration -p $PASSPHRASE

7.7.12.3.2 From a Windows host:


Save over SSH: plink $USER@$CARD_ADDRESS -pw $PASSWORD -batch save_configuration -p $PASSPHRASE > $FILE
Restore over SSH: type $FILE | plink $USER@$CARD_ADDRESS -pw $PASSWORD -batch restore_configuration -p $PASSPHRASE
(Require plink tools from putty)

Information – 279
CLI

Where:
• $USER is user name (the user shall have administrator profile)
• $PASSWORD is the user password
• $PASSPHRASE is any passphrase to encrypt/decrypt sensible data.
• $CARD_ADDRESS is IP or hostname of the card
• $FILE is a path to the JSON file (on your host computer) where the configuration is saved or restored.

7.7.12.4 Specifics

7.7.12.5 Access rights per profiles


Administrator Operator Viewer

save_configuration

restore_configuration

7.7.13 sanitize

7.7.13.1 Description
Sanitize command to return card to factory reset configuration.

7.7.13.2 Access
• Administrator

7.7.13.3 Help

sanitize
-h, --help Display help page
--withoutconfirmation Do factory reset of the card without confirmation
<cr> Do factory reset of the card

7.7.13.4 Access rights per profiles


Administrator Operator Viewer

sanitize

7.7.14 ssh-keygen

7.7.14.1 Description
Command used for generating the ssh keys.

Information – 280
CLI

7.7.14.2 Help

ssh-keygen
-h, --help Display help
<cr> Renew SSH keys

7.7.14.3 Specifics

7.7.14.4 Access rights per profiles


Administrator Operator Viewer

ssh-keygen

7.7.15 time

7.7.15.1 Description
Command used to display or change time and date.

7.7.15.2 Help
For Viewer and Operator profiles:

time -h
Usage: time [OPTION]...
Display time and date.

-h, --help display help page


-p, --print display date and time in YYYYMMDDhhmmss format

For Administrator profile:

time -h
Usage: time [OPTION]...
Display time and date, change time and date.
-h, --help display help page
-p, --print display date and time in YYYYMMDDhhmmss format
-s, --set <mode>
Mode values:
- set date and time (format YYYYMMDDhhmmss)
manual <date and time>
- set preferred and alternate NTP servers
ntpmanual <preferred server> <alternate server>
- automatically set date and time
ntpauto
Examples of usage:
-> Set date 2017-11-08 and time 22:00
time --set manual 201711082200

Information – 281
CLI

-> Set preferred and alternate NTP servers


time --set ntpmanual fr.pool.ntp.org de.pool.ntp.org

7.7.15.3 Examples of usage

-> Set date 2017-11-08 and time 22:00


time --set manual 201711082200
-> Set preferred and alternate NTP servers
time --set ntpmanual fr.pool.ntp.org de.pool.ntp.org

7.7.15.4 Specifics

7.7.15.5 Access rights per profiles


Administrator Operator Viewer

time (read-only) (read-only)

7.7.16 traceroute and traceroute6

7.7.16.1 Description
Traceroute and traceroute6 utilities are for checking the configuration of the network.

7.7.16.2 Help

traceroute
-h Specify maximum number of hops
<Hostname or IP> Remote system to trace

traceroute6
-h Specify maximum number of hops
<IPv6 address> IPv6 address

7.7.16.3 Specifics

7.7.16.4 Access rights per profiles


Administrator Operator Viewer

traceroute

traceroute6

Information – 282
CLI

7.7.17 whoami

7.7.17.1 Description
whoami displays current user information:
• Username
• Profile
• Realm

7.7.17.2 Specifics

7.7.17.3 Access rights per profiles


Administrator Operator Viewer

whoami

7.7.18 email-test

7.7.18.1 Description
mail-test sends test email to troubleshoot SMTP issues.

7.7.18.2 Help

Usage: email-test <command> ...


Test SMTP configuration.

Commands:
email-test -h, --help, Display help page

email-test -r, --recipient <recipient_address>


Send test email to the
<recipient_address> Email address of the recipient

7.7.18.3 Specifics

7.7.18.4 Access rights per profiles


Administrator Operator Viewer

email-test

Information – 283
CLI

7.7.19 systeminfo_statistics

7.7.19.1 Description
Displays the following system information usage:

1. CPU
a. usage : %
b. upSince : date since the system started
2. Ram
a. total: MB
b. free: MB
c. used: MB
d. tmpfs: temporary files usage (MB)
3. Flash
a. user data
i. total: MB
ii. free: MB
iii. used: MB

7.7.19.2 Help

systeminfo_statistics
Display systeminfo statistics

-h, --help Display the help page.

7.7.19.3 Specifics

7.7.19.4 Access rights per profiles


Administrator Operator Viewer

systeminfo_statistics

7.7.20 certificates

7.7.20.1 Description
Allows to manage certificates through the CLI.

7.7.20.2 Help

certificates <target> <action> <service_name>


<target> :
- local
<action> :
- print: provides a given certificate detailed information.
- revoke: revokes a given certificate.
- export: returns a given certificate contents.

Information – 284
Legal information

- import: upload a given certificate for the server CSR. This will replace the CSR
with the certificate given.
- csr: get the server CSR contents. This will create the CSR if not already existing.
<service_name>: mqtt/syslog/webserver

7.7.20.3 Examples of usage

7.7.20.3.1 From a linux host:


print over SSH: sshpass -p $PASSWORD ssh $USER@$CARD_ADDRESS certificates local print $SERVICE_NAME
revoke over SSH: sshpass -p $PASSWORD ssh $USER@$CARD_ADDRESS certificates local revoke $SERVICE_NAME
export over SSH: sshpass -p $PASSWORD ssh $USER@$CARD_ADDRESS certificates local export $SERVICE_NAME
import over SSH: cat $FILE | sshpass -p $PASSWORD ssh $USER@$CARD_ADDRESS certificates local import $SERVICE_NAME
csr over SSH: sshpass -p $PASSWORD ssh $USER@$CARD_ADDRESS certificates local csr mqtt

7.7.20.3.2 From a Windows host: (plink tools from putty is required)


print over SSH: plink $USER@$CARD_ADDRESS -pw $PASSWORD -batch certificates local print $SERVICE_NAME
revoke over SSH: plink $USER@$CARD_ADDRESS -pw $PASSWORD -batch certificates local revoke $SERVICE_NAME
export over SSH: plink $USER@$CARD_ADDRESS -pw $PASSWORD -batch certificates local export $SERVICE_NAME
import over SSH: type $FILE | plink $USER@$CARD_ADDRESS -pw $PASSWORD -batch certificates local import
$SERVICE_NAME
csr over SSH: plink $USER@$CARD_ADDRESS -pw $PASSWORD -batch certificates local csr mqtt

7.7.20.3.3 Where:
• $USER is user name (the user shall have administrator profile)
• $PASSWORD is the user password
• $PASSPHRASE is any passphrase to encrypt/decrypt sensible data.
• $CARD_ADDRESS is IP or hostname of the card
• $FILE is a certificate file
• $SERVICE_NAME is the name one of the following services : mqtt / syslog / webserver.

7.7.20.4 Specifics

7.7.20.5 Access rights per profiles


Administrator Operator Viewer

certificates

7.8 Legal information


This Network Module includes software components that are either licensed under various open source license, or under a
proprietary license.
For more information, see to the legal Information link from the main user interface in the footer.

7.8.1 Availability of Source Code


The source code of open source components that are made available by their licensors may be obtained upon written express
request by contacting [email protected]. Eaton reserves the right to charge minimal administrative costs, in
compliance with the terms of the underlying open source licenses, when the situation requires.

Information – 285
Legal information

7.8.2 Notice for Open Source Elements


This product includes software released under BSD or Apache v2 licenses, and developed by various projects, peoples and entities,
such as, but not limited to:
• * the Regents of the University of California, Berkeley and its contributors,
• * the OpenEvidence Project,
• * Oracle and/or its affiliates,
• * Mike Bostock,
• * JS Foundation and other contributors,
• * 2011-2014 Novus Partners, Inc.
This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit. (www.openssl.org/).
This product includes cryptographic software written by Eric Young ([email protected]).
This product includes software released under MIT license, and developed by various projects, peoples and entities, such as, but
not limited to:
• * Google, Inc.,
• * the AngularUI Team
• * Lucas Galfasó
• * nerv
• * Angular
• * Konstantin Skipor
• * Filippo Oretti, Dario Andrei
• * The angular-translate team and Pascal Precht,
• * Twitter, Inc.
• * Zeno Rocha
• * Kristopher Michael Kowal and contributors
• * JS Foundation and other contributors
• * Jonathan Hieb
• * Mike Grabski
• * Sachin N.
This product includes contents released under Creative Commons Attribution 4.0, Creative Commons Attribution-ShareAlike 3.0
Unported and SIL Open Font License licenses, and created by:
• * IcoMoon
• * Dave Gandy
• * Stephen Hutchings and the Typicons team.
In order to access the complete and up to date copyright information, licenses, and legal disclaimers, see the Legal Information
pages, available from the HTML user interface of the present product.

7.8.3 Notice for our proprietary (i.e. non-Open source) elements


Copyright © 2020 Eaton. This firmware is confidential and licensed under Eaton Proprietary License (EPL or EULA).
This firmware is not authorized to be used, duplicated, or disclosed to anyone without the prior written permission of Eaton.
Limitations, restrictions and exclusions of the Eaton applicable standard terms and conditions, such as its EPL and EULA, apply.

Information – 286
Acronyms and abbreviations

7.9 Acronyms and abbreviations


AC: Alternating current.
ATS: Automatic transfer switch is an electrical switch that switches a load between two sources.
AVR: Automatic Voltage Regulation provides stable voltage to keep equipment running in the optimal range.
BBDM: Broadcast Management Device (BACnet).
BMS: A Battery Management System is any electronic system that manages li-ion battery.
bps: bit per second
BOM: In Syslog, placing an encoded Byte Order Mark at the start of a text stream can indicates that the text is Unicode and identify
the encoding scheme used.
CA: Certificate Authority
CLI: Command Line Interface.
Aim is to interact with the Network Module by using commands in the form of successive lines of text (command lines).
CSR: Certificate Signing Request
DC: Direct current.
DCC: Device Communication Control (BACnet).
DN: Distinguished Name (LDAP).
DHCPv6: The Dynamic Host Configuration Protocol version 6 is a network protocol for configuring Internet Protocol version 6 (IPv6)
hosts with IP addresses, IP prefixes and other configuration data required to operate in an IPv6 network.
It is the IPv6 equivalent of the Dynamic Host Configuration Protocol for IPv4.
DNS: The Domain Name System is a hierarchical decentralized naming system for computers, services, or other resources
connected to the Internet or a private network.
DST: The daylight saving time.
EMP: Environmental monitoring probe
GID: Group Identifier is a numeric value used to represent a specific group (LDAP).HTTPS: HTTPS consists of communication over
Hypertext Transfer Protocol (HTTP) within a connection encrypted by Transport Layer Security (TLS).
IPP: Intelligent Power Protector is a web-based application that enables administrators to manage an Devices from a browser-based
management console. Administrators can monitor, manage, and control a single Device (UPS, ATS, PDU) locally and remotely. A
familiar browser interface provides secure access to the Device Administrator Software and Device Client Software from anywhere
on the network. Administrators may configure power failure settings and define UPS load segments for maximum uptime of critical
servers. The UPS can also be configured to extend runtimes for critical devices during utility power failures. For most UPSs, the
receptacles on the rear panel are divided into one or more groups, called load segments, which can be controlled independently. By
shutting down a load segment that is connected to less critical equipment, the runtime for more critical equipment is extended,
providing additional protection.
IPv4: Internet Protocol version 4 is the fourth version of the Internet Protocol (IP).
IPv6: Internet Protocol version 6 is the most recent version of the Internet Protocol (IP).
JSON: JavaScript Object Notation is an open-standard file format that uses human-readable text to transmit data objects consisting
of attribute–value pairs and array data types.
kVA: kilovolt-ampere.
LAN: A LAN is a local area network, a computer network covering a small local area, such as a home or office.
LDAP: The Lightweight Directory Access Protocol is an industry standard application protocol for accessing and maintaining
distributed directory information services over an Internet Protocol.
MAC: A media access control address of a computer is a unique identifier assigned to network interfaces for communications at
the data link layer of a network segment.
MIB: A management information base is a database used for managing the entities in a communication network. Most often
associated with the Simple Network Management Protocol (SNMP).
NTP: Network Time Protocol is a networking protocol for clock synchronization between computer systems.P/N: Part number.

Information – 287
Acronyms and abbreviations

RTC: Real time clock.


RTU: Remote Terminal Unit
S/N: Serial number.
SMTP: Simple Mail Transfer Protocol is an Internet standard for electronic mail (email) transmission.
SNMP: Simple Network Management Protocol is an Internet-standard protocol for collecting and organizing information about
managed devices on IP networks and for modifying that information to change device behavior.
SSH: Secure Shell is a cryptographic network protocol for operating network services securely over an unsecured network.
SSL: Secure Sockets Layer, is a cryptographic protocol used for network traffic.
TCP: Transmission Control Protocol
TLS: Transport Layer Security is cryptographic protocol that provide communications security over a computer network.
TFTP: Trivial File Transfer Protocol is a simple lockstep File Transfer Protocol which allows a client to get a file from or put a file onto
a remote host.
UID: User identifier (LDAP).
UTC: Coordinated Universal Time is the primary time standard by which the world regulates clocks and time.
UPS: An uninterruptible power supply is an electrical apparatus that provides emergency power to a load when the input power
source or mains power fails.
A UPS is typically used to protect hardware such as computers, data centers, telecommunication equipment or other electrical
equipment where an unexpected power disruption could cause injuries, fatalities, serious business disruption or data loss.

Information – 288
Acronyms and abbreviations

Information – 289
Action not allowed in Control/Schedule/Power outage policy

8 Troubleshooting

8.1 Action not allowed in Control/Schedule/Power outage policy


8.1.1 Symptom
Below message is displayed when you access the Control, Schedule or Power outage policy page.
This action is not allowed by the UPS.
To enable it, please refer to the user manual of the UPS and its instructions on how to configure the UPS settings and allow remote
commands.

8.1.2 Possible Cause


1- Remote commands are not allowed due to the UPS configuration (see the action below)
2- The UPS does not support remote commands.

8.1.3 Action
Refer to the UPS user manual and its instruction on how to configure the UPS settings and allow remote commands.
Example: UPS menu Settings>>>ON/OFF settings>>>Remote command>>>Enable.

8.2 Card wrong timestamp leads to "Full acquisition has failed"


error message on Software
8.2.1 Symptoms:
IPP/IPM shows the error message "The full data acquisition has failed" even if the credentials are correct.

8.2.2 Possible cause:


The Network module timestamp is not correct.
Probably the MQTT certificate is not valid at Network module date.

8.2.3 Action:
Set the right date, time and timezone. If possible, use a NTP server, refer to Contextual help>>>Settings>>>General>>>System
details>>>Time & date settings section.

8.3 Client server is not restarting


8.3.1 Symptom
Utility power has been restored, the UPS and its load segments are powered on, but the Client server does not restart.

8.3.2 Possible Cause


The “Automatic Power ON” server setup setting might be disabled.

Troubleshooting – 290
EMP communication status shows "Lost"

8.3.3 Action
In the server system BIOS, change the setting for Automatic Power ON to "Enabled".

8.4 EMP communication status shows "Lost"


In the Network Module, in Contextual help>>>Environment>>>Commissioning/Status , EMPs are missing in the Sensor
commissioning table.

8.4.1 Symptom #1
The connection status of the sensor is "Lost"

8.4.1.1 Possible causes


The EMPs are not powered by the Network module.

8.4.1.2 Action #1-1


Launch again the discovery, if it is still not ok, go to Action #1-2.

8.4.1.3 Action #1-2


1- Check the EMPs connection and cables.
Refer to the sections Servicing the EMP>>>Installing the EMP>>>Cabling the first EMP to the device and Servicing the
EMP>>>Installing the EMP>>>Daisy chaining 3 EMPs .
2- Disconnect and reconnect the USB to RS485 cable.
3- Launch the discovery, if it is still not ok, go to Action #1-3.

8.4.1.4 Action #1-3


1- Reboot the Network module.
2- Launch the discovery.

8.5 EMP detection fails at discovery stage


In the Network Module, in Contextual help>>>Environment>>>Commissioning/Status, EMPs are missing in the Sensor
commissioning table.

8.5.1 Symptom #1
The EMPs green RJ45 LED (FROM DEVICE) is not ON.

8.5.1.1 Possible causes


The EMPs are not powered by the Network module.

8.5.1.2 Action #1-1


Launch again the discovery, if it is still not ok, go to Action #1-2.

Troubleshooting – 291
How do I log in if I forgot my password?

8.5.1.3 Action #1-2


1- Check the EMPs connection and cables.
Refer to the sections Servicing the EMP>>>Installing the EMP>>>Cabling the first EMP to the device and Servicing the
EMP>>>Installing the EMP>>>Daisy chaining 3 EMPs.
2- Disconnect and reconnect the USB to RS485 cable.
3- Launch the discovery, if it is still not ok, go to Action #1-3.

8.5.1.4 Action #1-3


1- Reboot the Network module.
2- Launch the discovery.

8.5.2 Symptom #2
The EMPs orange RJ45 LEDs are not blinking.

8.5.2.1 Possible causes


C#1: the EMP address switches are all set to 0.
C#2: the EMPs are daisy chained, the Modbus address is the same on the missing EMPs.

8.5.2.2 Action #2-1


1- Change the address of the EMPs to have different address and avoid all switches to 0.
Refer to the section Servicing the EMP>>>Defining EMPs address and termination>>>Manual addressing.
2- Disconnect and reconnect the USB to RS485 cable. The address change is only taken into account after an EMP power-up.
3- Launch the discovery, if it is still not ok, go to Action #2-2.

8.5.2.3 Action #2-2


1- Reboot the Network module.
Refer to the section Contextual help>>>Maintenance>>>Services>>>Reboot.
2- Launch the discovery.

8.6 How do I log in if I forgot my password?


8.6.1 Action
• Ask your administrator for password initialization.
• If you are the main administrator, your password can be reset manually by following steps described in the Servicing the
Network Management Module>>>Recovering main administrator password.

Troubleshooting – 292
Software is not able to communicate with the Network module

8.7 Software is not able to communicate with the Network


module
8.7.1 Symptoms
• In the Network Module, in Contextual help>>>Protection>>>Agent list>>>Agent list table, agent is showing "Lost" as a
status.
• In the Network Module, in Contextual help>>>Settings>>>Certificate>>>Trusted remote certificates, the status of
the Protected applications (MQTT) is showing "Not valid yet".
• IPP/IPM shows "The authentication has failed", "The notifications reception encountered error".

8.7.2 Possible cause


The IPP/IPM certificate is not yet valid for the Network Module.
Certificates of IPP/IPM and the Network Module are not matching so that authentication and encryption of connections between
the Network Module and the shutdown agents is not working.

8.7.3 Setup
IPP/IPM is started.
Network module is connected to the UPS and to the network.

8.7.4 Action #1
Check if the IPP/IPM certificate validity for the Network Module.
STEP 1: Connect to the Network Module
• On a network computer, launch a supported web browser. The browser window appears.
• In the Address/Location field, enter: https://xxx.xxx.xxx.xxx/ where xxx.xxx.xxx.xxx is the static IP address of the Network
Module.
• The log in screen appears.
• Enter the user name in the User Name field.
• Enter the password in the Password field.
• Click Login. The Network Module web interface appears.
STEP 2: Navigate to Settings/Certificates page
STEP 3: In the Trusted remote certificates section, check the status of the Protected applications (MQTT).
If it is "Valid" go to Action#2 STEP 2, if it is "Not yet valid", time of the need to be synchronized with IPP/IPM.
STEP 4: Synchronize the time of the Network Module with IPP/IPM and check that the status of the Protected applications
(MQTT) is now valid.
Communication will then recover, if not go to Action#2 STEP 2.

8.7.5 Action #2
Pair agent to the Network Module with automatic acceptance (recommended in case the installation is done in a secure and trusted
network).

For manual pairing (maximum security), go to Servicing the Network Management Module>>>Pairing agent to the
Network Module section and then go to STEP 2, item 1.

STEP 1: Connect to the Network Module.


• On a network computer, launch a supported web browser. The browser window appears.
• In the Address/Location field, enter: https://xxx.xxx.xxx.xxx/ where xxx.xxx.xxx.xxx is the static IP address of the Network
Module.

Troubleshooting – 293
LDAP configuration/commissioning is not working

• The log in screen appears.


• Enter the user name in the User Name field.
• Enter the password in the Password field.
• Click Login. The Network Module web interface appears.
STEP 2: Navigate to Protection/Agents list page.
STEP 3: In the Pairing with shutdown agents section, select the time to accept new agents and press the Start button
and Continue. During the selected timeframe, new agent connections to the Network Module are automatically trusted and
accepted.
STEP 4: Action on the agent (IPP/IPM) while the time to accepts new agents is running on the Network Module
Remove the Network module certificate file(s) *.0 that is (are) located in the folder Eaton\IntelligentPowerProtector\configs\tls.

8.8 LDAP configuration/commissioning is not working


Refer to the section Servicing the Network Management Module>>>Commissioning/Testing LDAP.

8.9 Modbus communication doesn't work


8.9.1 Symptoms
• Communication doesn't work

Refer to the section Servicing the Network Management Module>>>Configuring Modbus to get configuration and
testing information.

8.9.2 Possible cause


• Incorrect communication parameters.
Verify that the communication parameters are set to the desired settings.For Modbus TCP configuration refer to the
section Contextual help>>>Settings>>>Modbus>>>Modbus TCP.
For Modbus RTU configuration refer to the section Contextual help>>>Settings>>>Modbus>>>Modbus RTU.
• RS-485 communication lines are reversed
For two-wire networks refer to the section Installing the Network Management Module>>>Wiring the RS-485 Modbus RTU
terminal>>>Two-wire networks.
For four-wire networks refer to the section Installing the Network Management Module>>>Wiring the RS-485 Modbus RTU
terminal>>>Four-wire networks.
• If the Modbus Card is the last device installed in the network chain or the length of the network cable is excessive,
termination needs to be enabled.
Verify the termination settings and refer to the section Installing the Network Management Module>>>Wiring the RS-485
Modbus RTU terminal>>>Configuring the termination.

Troubleshooting – 294
Password change in My profile is not working

8.10 Password change in My profile is not working


8.10.1 Symptoms

The password change shows "Invalid credentials" when I try to change my password in My profile menu:

8.10.2 Possible cause


The password has already been changed once within a day period.

8.10.3 Action
Let one day between your last password change and retry.

8.11 SNMPv3 password management issue with Save and


Restore
8.11.1 Affected FW versions
This issue affects SNMP configuration done on versions prior to 1.7.0 when applied to versions 1.7.0 or above.

8.11.2 Symptom
SNMPv3 connectivity is not properly working after a restore settings on a 1.7.0 version or above.

8.11.3 Cause
The SNMPv3 was configured prior to 1.7.0.
In that case, SNMPv3 configuration is not well managed by the Save and by the Restore settings.

8.11.4 Action
Reconfigure your SNMPv3 users and passwords on versions 1.7.0 or above and Save the settings.
The SNMPv3 configuration can then be Restored.

8.12 The alarm list has been cleared after an upgrade


8.12.1 Symptom
After a FW upgrade, the alarm list has been cleared and is now empty.

8.12.2 Action
The alarm list has been saved on a csv file and can be retrieved using Rest API calls.

Troubleshooting – 295
The Network Module fails to boot after upgrading the firmware

8.12.2.1 Authenticate:

curl --location --request POST 'https://{{domain}}/rest/mbdetnrs/1.0/oauth2/token' \


--header 'Content-Type: application/json' \
--data-raw '{ "username":"admin", "password":"supersecretpassword", "grant_type":"password",
"scope":"GUIAccess" }'

8.12.2.2 Get Alarm Log Backup:

curl --location --request GET 'https://{{domain}}/rest/mbdetnrs/1.0/alarmService/actions/


downloadBackup' \
--header 'Authorization: Bearer {{access_token}}'

8.13 The Network Module fails to boot after upgrading the


firmware
8.13.1 Possible Cause
1- The IP address has changed.
2- The Network module LED shows solid red after the upgrade.
3- The first boot after the upgrade takes a longer time.
Note: If the application is corrupt, due to an interruption while flashing the firmware for example, the boot will be done on previous
firmware.

8.13.2 Action
1- Recover the IP address and connect to the card.
2- Reset the Network module by using the Restart button on the front panel.
3- Wait until the Network module LED shows flashing green.
Refer to Installing the Network Management Module>>>Accessing the Network Module>>>Finding and setting the IP address
section.

8.14 Web user interface is not up to date after a FW upgrade


8.14.1 Symptom
After an upgrade:
• The Web interface is not up to date
• New features of the new FW are not displayed
• An infinite spinner is displayed on a tile

8.14.1.1 Possible causes


The browser is displaying the Web interface through the cache that contains previous FW data.

8.14.1.2 Action
Empty the cache of your browser using F5 or CTRL+F5.

Troubleshooting – 296