The document outlines electrical specifications and requirements for a retail space in Plano, Texas, adhering to the ASME A17.3 code. It includes details on outlet placements, GFCI and AFCI requirements, and installation responsibilities for the electrical contractor. Additionally, it emphasizes compliance with safety standards and proper installation practices for electrical fixtures and systems.

Uploaded by

decided721
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3 views

3

The document outlines electrical specifications and requirements for a retail space in Plano, Texas, adhering to the ASME A17.3 code. It includes details on outlet placements, GFCI and AFCI requirements, and installation responsibilities for the electrical contractor. Additionally, it emphasizes compliance with safety standards and proper installation practices for electrical fixtures and systems.

Uploaded by

decided721
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

CLIENT :

Financial Manager :

NOTE
MEP applies Texas's ASME A17.3 code.

8604 PRESTON ROAD RETAIL4 SUITE 119 PLANO, TEXAS 75204


ELECTRICAL LEGEND

PRESTON VILLAGE CENTER


110V DUPLEX RECEPTACLE 12" AFF
GROUND FAULT CIRCUIT INTERRUPT
DISPLAY SHELF TYPE 1 DISPLAY SHELF TYPE 2
GFCI

WP 110V DUPLEX RECEPTACLE WATERPROOF


D SINGLE POLE SWITCH w/ DIMMER DUPLEX RECEPTACLE 12" AFF
3 THREE WAY SINGLE POLE SWITCH
4 FOUR WAY SINGLE POLE SWITCH
SINGLE POLE SWITCH
READING LIGHT IN CEILING
CEILING FAN w/LIGHTING

EXISTING OUTLETS TO REMAIN WHERE POSSIBLE.


OUTLETS, TYPICAL: UNLESS OTHERWISE NOTED, HEIGHT OF
OUTLETS AND SWITCHES WILL BE AS FOLLOWS:
DISPLAY SHELF TYPE 3 OUTLETS: CENTER 12: A.F.F. - COORDINATE WITH BASEBOARD
HEIGHT AS NECESSARY.
SWITCHES: CENTER 48" A.F.F.
BATHROOM EXHAUST FANS: ENERGY STAR RATED AND DUCTED TO
TERMINATE OUTSIDE.

GENERAL NOTE

90" 1. ARC FAULT(AFCI) REQUIRED IN FAMILY RMS, DINING RMS, PARLORS, LIBARIES, DENS
BEDROOMS, SUN ROOMS, REC RMS, CLOSETS, AND HALLWAYS AND LIGHTING.
36"
GROUND FAULT IS REQUIRED IN BATH RMS, GARAGES, ACCESSORY AREAS, EXTERIOR,
CRAWLSPACES, BASEMENTS, DISHWASHERS AND DIPOSALS.
NOTE TO SHOW COMLIANCE WITH ARC-FAULT AND GROUND FAULT OUTLETS PER ART 210.12
30" AND 210.8 CEC 2019
STAND-ALONE 2. ELECTRICAL OUTLETS IN SPACES SUCH AS BATHROOMS, LAUNDRY ROOMS, POWDER ROOMS,
DISPLAY SHELVES 144" CRAWL SPACES, UNFINISHED BASEMENT, GARAGE AND OURSIDE ARE REQUIRED TO HAVE GFCI
CHECKOUT
GFCI

PROTECTION
COUNTER
ELECTRICAL NOTES:

1. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR A COMPLETE INSTALLATION TO CODE, INCLUDING


ANY MATERIAL NOT INCLUDED ON DRAWINGS NECESSARY FOR CODE COMPLIANCE.
118" 2. ELECTRICAL CONTRACTOR TO COORDINATE DRILLING FOR ELECTRICAL RUNS WITH G.C,
3. VERIFY ALL LOCATIONS OF LIGHT/OUTLETS WITH OWNER/ARCHITECT PRIOR TO PULLING WIRE TO
DEVICES.
4. CONTRACTORS IS RESPONSIBLE FOR SIZING AND INSTALLING ALL ELECTRICAL SERVICE ACCORDING
TO LOADS OF EQUIPMENT REQUIRED AND ACCORDING TO N.E.C. Address:
5. VERIFY FIXTURE SUBSTITUTIONS WITH ARCHITECT. TEXAS, USA

6. DUPLEX RECEPTACLES TO BE GFI WHERE REQUIRED BY CODE.


7. INSTALL WIRES IN CONDUIT WHERE REQUIRED BY CODE.
8. ALL EXISTING OUTLETS NEED TO BE GROUNDED.
9. PROVIDE LIGHT FIXTURES IN TUB/SHOWER ENCLOSURE ARE LABELED "SUITABLE FOR DAMP
LOCATIONS" ELECTRICAL PLAN
10. ALL RECESSED LIGHT FIXTURES SHALL BE IC RATED OR FIXTURES NOT IDENTIFIED FOR CONTACT
WITH INSULATION SHALL HAVE ALL RECESSED PARTS SPACES AT LEAST 1/2" FROM COMBUSTIBLE
MATERIALS AND 3" FROM THERMAL INSULATION. RECESSED CANS SHALL ALSO BE AIR-TIGHT RATED.
1/4"=1'-0"

A103