INBODY USER

The InBody270 User's Manual provides essential information regarding the installation, operation, and maintenance of the InBody270 body composition measurement device. It includes safety warnings, installation instructions, test procedures, and troubleshooting tips, as well as contact information for customer service across various regions. The manual emphasizes compliance with safety regulations to prevent injury or equipment damage.

Uploaded by

biomedicalvcare
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
35 views

INBODY USER

The InBody270 User's Manual provides essential information regarding the installation, operation, and maintenance of the InBody270 body composition measurement device. It includes safety warnings, installation instructions, test procedures, and troubleshooting tips, as well as contact information for customer service across various regions. The manual emphasizes compliance with safety regulations to prevent injury or equipment damage.

Uploaded by

biomedicalvcare
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 36

User’s Manual

270_manual_ENG_B_150608.indd 2 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
Please note the important information below before reading this manual.
This product can also be used for medical purposes as the InBody270 measures body composition.
UTION NOTE DANGER

Warning
참조 주의
Failure to comply with safety warnings and regulations can cause serious injury or death.
UTION NOTE DANGER

Caution
참조 주의
Failure to comply with safety cautions and regulations can cause injury or property damage.

InBody Co., Ltd. [HEAD OFFICE]


InBody Bldg., 54, Nonhyeon-ro 2-gil, Gangnam-gu, Seoul 135-960 KOREA
TEL: +82-2-501-3939
FAX: +82-2-578-2716
Website: http://www.inbody.com
E-mail: [email protected]

ⓒ2015 InBody Co., Ltd. All rights reserved.


Reproduction, adaptation, or translation of this manual is prohibited without prior written consent from InBody Co., Ltd
under the copyright laws. This manual might have typographical errors, and its content can be changed without a
prior notice. InBody Co., Ltd shall not be liable for any errors, incidental, or consequential damages that occurred
by not complying with the content of the User’s Manual.
Visit our website http://www.inbody.com to view and download further information about the functions of the
InBody270, the explanation of results output, and more. InBody Co., Ltd reserves the right to modify the appearance,
specifications, and etc. of the InBody270 to improve the quality of the product, without prior notice for reasons of
performance improvement.

EU Representative. [EUROPE]
DongBang Acuprime. 1 Forrest Units, Hennock Road East, Marsh Barton, Exeter EX2 8RU, U.K
TEL: +44-1392-829500 FAX: +44-1392-823232 Website: http://www.inbody.com E-mail: [email protected]

Australian Sponsor. [AUSTRALIA]


Emergo AUSTRALIA. Level 20, Tower Ⅱ, Darling Park, 201 Sussex Street, Sydney, NSW 2000, AUSTRALIA
TEL: +61-2-9006-1662 FAX: +61-2-9006-1010 Website: http://www.emergogroup.com E-mail: [email protected]

Customer Service Information


InBody [USA]
13850 Cerritos Corporate Dr., Unit C, Cerritos, CA 90703, USA
TEL: +1-323-932-6503 FAX: +1-323-952-5009 Website: http://www.inbodyusa.com E-mail: [email protected]

InBody Japan Inc. [JAPAN]


Tani Bldg., 1-28-6, Kameido, Koto-ku, Tokyo 136-0071 JAPAN
TEL: +81-3-5875-5780 FAX: +81-3-5875-5781 Website: http://www.inbody.co.jp E-mail: [email protected]

InBody China. [CHINA]


904, Xing Di Plaza, No. 1698 Yishan Road, Shanghai, 201103, CHINA
TEL: +86-21-64439738, 9739, 9705 FAX: +86-21-64439706 Website: http://www.inbody.com E-mail: [email protected]

ⓒ2015 InBody Co., Ltd. All rights reserved. BM-ENG-F9-B-150608

270_manual_ENG_B_150608.indd 3 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
User’s Manual Contents

I. InBody270 Installation
A. Product Components 4
B. Operating Environment 5
C. Installation Instructions 5
D. Initial Setup 8
E. Connecting Printer, Thermal Printer, Stadiometer, 12
Blood Pressure Monitor, Barcode Reader and SD400
F. Maintenance 15

II. InBody Test


A. Precautionary Steps 16
B. Test Instructions 17
C. Test Posture 19

III. Transportation and Storage


A. Cautions during Transportation 20
B. Repacking Instructions 20
C. Transportation and Storage Environment 20

IV. Frequently Asked Questions (FAQ)


A. Regarding the InBody 21
B. Regarding the InBody Test 23

V. Others
A. Exterior and Functions 24
B. Safety Information 27
C. Classification 29
D. Specifications 29
E. EMC declaration 31

270_manual_ENG_B_150608.indd 4 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
I. InBody270 Installation
A. Product Components
The InBody270 consists of the following components. Please make sure all of the following components
are present.
* Please inspect each component of the InBody270 for defects prior to installation.

❶ InBody270
❷ Adapter (DC 12V, 3.4A) 1 EA
Input Buttons
❸ Power cord 1 EA
❹ User’s Manual 1 EA

Upper part
Hand electrodes

Foot electrodes
Hinge

Footplate

❶ ❹

270_manual_ENG_B_150608.indd 4 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
B. Operating Environment
Please make sure that the environment is adequate for the InBody270 installation. This equipment is designed
for indoor use. If installing outdoors, the following requirements must be fulfilled.

Temperature range 10 ~ 40℃ (50 ~ 104℉)


Relative humidity 30 ~ 75% RH
Atmospheric pressure 70 ~ 106kPa

C. Installation Instructions
1. Open the packing box of the InBody270 and remove the packing pads. Then take the InBody270 out of
the box.
Polyethylene foam cover
Packing pads

CAUTION NOTE DANGER

Caution
참조 주의
• If you have any problems installing your InBody270, please contact InBody for assistance.
• Do not transport the equipment by holding the screen portion or the joints of the hand electrodes.
• Keep the packing materials provided for repacking the equipment in the future. Other wastes should be
disposed of according to relevant laws and regulations.

2. While holding the upper part lock button, raise the upper part of the InBody270 and remove the polyethylene
foam cover.

Hinge

* Please refer to the following illustrations to properly transport the equipment.

CAUTION NOTE DANGER

Caution
참조 주의
• Using the InBody270 on carpet may cause static electricity, which could damage the equipment. If installing
the InBody270 on carpet is unavoidable, please use an antistatic mat.
• Install the InBody270 on a leveled, non-vibrating surface. Installing the equipment on an uneven surface
may cause the examinee to fall down. Test results may also be inaccurate.
• Never clean the hand and foot electrodes with liquid spray or detergent directly. The equipment may corrode
and/or malfunction if the liquid or detergent leaks inside. Use the InBody Tissue when cleaning the InBody270.

270_manual_ENG_B_150608.indd 5 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
3. Level the InBody270 by rotating the leveling screws under the footplate to the left and right so that the
air bubble is centered.
* Leveling the equipment is necessary for accurate measurement of weight. There are a total of 4 leveling screws.

Level Indicator

Leveled Not leveled

Leveling screws under the footplate

CAUTION NOTE DANGER

Caution
참조 주의
• Avoid injuring your hands when rotating the leveling screws under the footplate.

4. Connect the adapter (❷) to the power input port, which is located on the rear panel (❶). Connect the adapter (❷)
to the power cord (❸). Plug the power cord (❸) into a grounded 3-socket outlet.
* The InBody270 can be used in connection with other equipment such as a stadiometer, a blood pressure monitor, data management
software called Lookin’Body, or a barcode reader. For more information, please refer to 'I. InBody270 Installation E.Connecting Printer,
Thermal Printer, Stadiometer, Blood Pressure Monitor, Barcode Reader and SD400' in User's Manual.


Power input port
Rear panel InBody

Grounded outlet
❷ ❸

3-socket outlet

CAUTION NOTE DANGER

Warning
참조 주의
• Do not place the InBody270 in a location making it difficult to disconnect the power cord.
• Do not plug in or pull out the power cord with wet hands. There is a risk of an electric shock.
• Always use an outlet connected to the power (AC 100 - 240 V). Using other power rated outlets may result in
fire or malfunction.
• When using a power surge protector, make sure that the outlet or the extension cable has adequate power capacity.

• Do not disassemble or modify the equipment including internal parts without written consent from the
manufacturer. This may cause electric shock or injury, product malfunction, inaccurate results, and will
void the manufacturer’s warranty.

270_manual_ENG_B_150608.indd 6 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
• If this equipment is modified, appropriate inspection and testing must be conducted to ensure continued safe
use of equipment.
• Do not directly contact the InBody270 with any other electronic device when the InBody270 is on.
This may result in an electric shock.
CAUTION NOTE DANGER

Caution
참조 주의
• If the InBody270 is not plugged into a grounded outlet, it may cause damage through electric surges or
product malfunction. This may affect the test results.
• The test results may be inaccurate if the InBody270 is under electrical interference. Do not install the
InBody270 near products that generate electrical interference such as fluorescent lights, large AC motor
equipment(treadmill, vibration plate, refrigerator, air-conditioner, compressor, etc.), high-frequency thermal
therapy equipments, or heating appliances. Do not share the power source of the InBody270 with other
electrical devices. This may affect the test results.
• When connecting the InBody270 with other test equipment, turn on the other equipment first. When
turning off other equipment, turn off the InBody270 first. This is necessary to minimize electrical surges
on the InBody270.
• Always use the specified adapter provided by InBody as it is a part of the InBody270. Using other adapters
may result in malfunction of the InBody270.
• Operation of the InBody270 2,000m above sea level may affect the weight measurement.
• Adapter must be arranged so that easily cut off the power when a problem occurs in the InBody270.

5. Flip the power switch to turn on the InBody270.

InBody

Power switch

270_manual_ENG_B_150608.indd 7 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
D. Initial Setup
1. The InBody270 automatically starts booting when it is turned on. While booting, it performs a self
weight calibration.
* While booting (about 5 minutes), make sure there is nothing on top of the footplate. Please do not stand on the footplate, or
place objects on the footplate.

2. Press the [Administrator Menu] button on the screen, which appears when no one is on the footplate.

Administrator Menu

3. Input the password (default password: 0000) to access the Administrator Menu.

4. The Administrator Menu will give you access to ‘Setup’ and ‘Troubleshooting’.

Setup Troubleshooting
8

270_manual_ENG_B_150608.indd 8 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
1) Setup: Configure settings and manage data according to the test environment.

01. Date/Time/Units/Country/Language/Password/Volume
: Change or modify the InBody’s basic settings.

02. Self Mode/Professional Mode


• Self Mode: The examinee takes the InBody Test by entering only his/her height.
Throughout the test, instructions and the InBody Information will be shown on screen.
• Professional Mode: An examiner is present and guiding the examinee through the InBody Test.

03. N/A

04. N/A

05. Bypass Age/Gender


: The examinees can bypass inputting their age or gender if the test environment is designed for testing
only adults or a specific gender.

06. View/Print/Delete Data


: The administrator can manage test results using ID.

07. Export Data as Excel


: You can export test results as an excel file on a USB Thumb Drive. Exported test results can be viewed
as an excel file on a computer.

08. Data Backup/Restoration/Combine


: Back up InBody Test results to a USB Thumb Drive, or restore test results using a backup file on a
USB Thumb Drive, or add test results using a backup file on a USB Thumb Drive to the InBody.

09. Printer Setup


: Connect the printer to the InBody. A connected printer will allow for printing results sheets after testing.

10. Results Sheet Types


: Select which results sheets to utilize with the InBody270.
(InBody Results Sheet, InBody Results Sheet for Children, and Thermal Results Sheet).

11. Automatic Printing Options


: This option enables automatic printing of the Results Sheet after each test. Up to two copies can be
printed at a time.

12. Paper Types


: Select the paper type for printed results sheets. Options include blank A4 paper or pre-printed InBody
Results Sheets provided by InBody.

13. Outputs/Interpretations for Results Sheet


: This option allows you to configure the outputs and interpretations appearing on the right-hand side of
the InBody Results Sheet, the InBody Results Sheet for Children, and the Thermal Results Sheet.

270_manual_ENG_B_150608.indd 9 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
14. Results Sheet Custom Logo
: Insert a logo on upper right corner of the printed results sheet.
* Please contact InBody for help with uploading or modifying a logo.

15. Printing Alignment


: Adjust the alignment of where the results will be printed on the results sheets.

16. Internet Options


: You can connect the InBody wirelessly to the network when using the data management software,
Lookin’Body.

17. Bluetooth
: Connect the InBody270 to data management software Lookin’Body via Bluetooth.

18. Manual/Automatic Weight


: Select whether to have weight automatically weighed or manually entered before testing.

19. Adjust Weight


: Adjust measured weight by a fixed value on the InBody. (Example: Workout clothes at the gym are
approximately 0.2kg; most examinees are assumed to be wearing workout clothes, so the examiner
may adjust the set value to -0.2kg.)

20. Normal Range


: Set the normal range for BMI, Percent Body Fat and Waist-Hip Ratio.
* The ideal value of BMI may also be set.

21. N/A

22. Standard Child Growth Curve


: Set the type of standard child growth curve to use on the InBody Result Sheet for Children.

23. Touchscreen Alignment


: Adjust the alignment of the touchscreen.

24. Customer Service Information


: Save the customer service contact information. Please refer to the customer service information
if you have any inquiries regarding the InBody Test, or problems that cannot be resolved through the
‘Troubleshooting’ menu.

25. Auto-Lock
: Set the password and wait time for auto-lock on the InBody270.

26. Serial Connect


: This option allows you to connect InBody with Lookin’Body member management program for PC
or with other devices over serial connection.

10

270_manual_ENG_B_150608.indd 10 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
2) Troubleshooting: See additional information on how to use the InBody. Refer to troubleshooting checklist
when there are problems that occur during the InBody use/test.

01. Customer Service Information


: See the customer service contact information saved under the Setup of the Administrator Menu
‘24. Customer Service Information’. Please contact the customer service if your problem cannot be
resolved through the ‘Troubleshooting’ or if you need further inquiries regarding the InBody Test.

02. Results Sheet does not print.


: View the troubleshooting checklist when the Results Sheet does not print by the printer connected
to the InBody.

03. Weight is not being measured.


: View the troubleshooting checklist when weight is not being measured, after stepping on to the
InBody footplate.

04. Weight measurement seems to be inaccurate.


: View the troubleshooting checklist when the weight measurement seems to be inaccurate.

05. The InBody Test has stopped.


: View the troubleshooting checklist when the InBody Test has stopped.

06. Test results seem to be inaccurate.


: View the troubleshooting checklist when the test results seem to be inaccurate.

11

270_manual_ENG_B_150608.indd 11 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
E. Connecting Printer, Thermal Printer, Stadiometer, Blood Pressure Monitor,
Barcode Reader and SD400
1. Printer
In order to print InBody Results Sheets, an InBody270 compatible printer is required.
* A list of printers compatible with the InBody270 can be found at http://www.inbodyservice.com.

1) First turn off the InBody270 and then the printer.


* You may experience connection issues in connecting the printer to the InBody270 if the InBody is turned on.

2) Plug the USB cable provided with the printer into the USB HOST port on the rear panel of the InBody270
and plug the other end of the USB cable into the printer.

USB HOST port

3) Turn on the printer.


4) Turn on the InBody270 and setup your printer under Settings of the Administrator Menu ‘09. Printer Setup’.
5) You can edit your printing settings under Settings of the Administrator Menu from ‘10. Results Sheet Types’
through ‘15. Printing Alignment’.

2. Thermal Printer
Connect thermal printer to the InBody270 to print Thermal Results Sheet.
* For best result, the InBody270 should be turned off when connecting to thermal printer.

1) Turn off the InBody270.


* For best result, the InBody270 should be turned off when connecting to thermal printer.

2) Connect the serial cable supplied with your thermal printer to the 9-pin serial port on the rear panel of the
InBody270. Then, connect the other end of the serial cable to the serial port on to thermal printer.

9-pin serial port

3) Turns on the thermal printer.


4) Turn on the InBody270. Go to Setup in Administrator Menu and select ‘Thermal Printer’ under ‘26. Serial
Connect’.
5) Go to Setup in Administrator Menu and select ‘Thermal Results Sheet’ under ‘10. Results Sheet Types’ and
configure the items printed to the Thermal Results Sheet under ‘13. Outputs/Interpretations for Results Sheet’.

12

270_manual_ENG_B_150608.indd 12 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
3. Stadiometer
If a stadiometer is connected to the InBody270, the height values measured by the stadiometer will be sent
directly to the InBody270.
* Always connect a stadiometer from InBody.

1) First turn off the InBody270 and then the stadiometer.


* You may experience connection issues in connecting the stadiometer to the InBody270 if the InBody is turned on.

2) Plug the serial cable provided with the stadiometer to the 9-pin serial port on the rear panel of the
InBody270.

9-pin serial port

3) Turn on the stadiometer.


4) Turn on the InBody270. Go to Setup in Administrator Menu and select ‘Stadiometer’ under ‘26. Serial
Connect’. If the stadiometer is connected to the InBody270, the stadiometer icon ( ) will appear
on the top left corner of the screen when no one is on the footplate.

4. Blood Pressure Monitor


If a blood pressure monitor is connected to the InBody270, the blood pressure values measured by the
blood pressure monitor will be sent directly to the InBody270.
* Always connect a blood pressure monitor from InBody.
* If you select to print blood pressure measurements under Settings of the Administrator Menu ‘13. Outputs/Interpretations for Results
Sheet’, the blood pressure measurements will be printed on the InBody Results Sheet.

1) First turn off the InBody270 and then the blood pressure monitor.
* You may experience connection issues in connecting the blood pressure monitor to the InBody270 if the InBody is turned on.

2) Plug the serial cable provided with the blood pressure monitor to the 9-pin serial port on the rear panel of
the InBody270.

9-pin serial port

3) Turn on the blood pressure monitor.


4) Turn on the InBody270. Go to Setup in Administrator Menu and select ‘Blood Pressure Monitor’ under
‘26. Serial Connect’. If the blood pressure monitor is connected to the InBody270, the blood pressure
monitor icon ( ) will appear on the top left corner of the screen when no one is on the footplate.

13

270_manual_ENG_B_150608.indd 13 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
5. Barcode Reader
If a barcode reader is connected to the InBody270, the ID can be inputted automatically.
* If the InBody cannot recognize the barcode reader, please contact InBody.

1) First turn off the InBody270.


* You may experience connection issues in connecting the barcode reader to the InBody270 if the InBody is turned on.

2) Plug the USB cable of the barcode reader into the USB HOST port on the rear panel of the InBody270.

USB HOST port

3) Turn on the InBody270. If the barcode reader is connected to the InBody270, the barcode reader
icon( ) will appear on the top left corner of the screen when no one is on the footplate.

6. SD400
Connect the SD400 to the InBody270 in order to connect the stadiometer and the blood pressure monitor
simultaneously.

1) Turn off the InBody270.


* For best result, the InBody270 should be turned off when connecting to thermal printer.

2) Connect the serial cable supplied with the SD400 to the 9-pin serial port on the rear panel of the
InBody270.
Then, connect the other end of the serial cable to the serial port of the SD400.

9-pin serial port

3) Connect your devices (such as stadiometer and blood pressure monitor) to the ports on the SD400 and turn
on the devices.
4) Turn on the InBody270. Go to Setup in Administrator Menu. Select ‘SD400’ under ‘26. Serial Connect’
and select the devices you have connected to the ports on the SD400. When your devices are connected,
the icons ( ) of your devices will appear in the top left of the test standby screen.

14

270_manual_ENG_B_150608.indd 14 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
F. Maintenance
CAUTION NOTE DANGER

Caution
참조 주의
• Do not bend the handles of the hand electrodes or rotate them in the reverse direction beyond its limitation.
• Do not extend the handles of the hand electrodes beyond its limitation.
• Do not place any objects on the footplate.
• Do not apply excessive force on the equipment.
• Turn off the equipment if you are not using it for a day or longer.
• Do not allow any liquid substances to contact the equipment directly. Keep food and drinks away from the
equipment. Substances getting inside the equipment can cause critical damage to the electronic components.
• Use a lint-free cloth to gently wipe the external surface of the equipment about once every week. Be careful not
to scratch the LCD screen.
• InBody270 does not need regular maintenance. If some problems occur while operating the device, get in touch
with the store where you purchased it or A/S manager.
We do not take the responsibility about problems caused by any arbitrary repairs.

15

270_manual_ENG_B_150608.indd 15 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
II. InBody Test
A. Precautionary Steps
CAUTION NOTE DANGER

Warning
참조 주의
• Individuals with medical implant devices such as pacemakers, or essential support devices such as patient
monitoring systems, must not use this equipment. Safe, low-level currents will flow through the body during
the test, which may cause malfunctioning of the device or endanger lives.
• Bioelectrical Impedance Analysis (BIA) uses safe low level currents, which are not harmful to the body. However,

we do not recommend pregnant women test.


• Children and people with limited mobility should be supervised or assisted when attempting to test on the InBody.
• After an individual with any kind of contagious disease or infection tests on the InBody, use an InBody Tissue

to clean the equipment.

CAUTION NOTE DANGER

Caution
참조 주의
• Stand upright for about 5 minutes before testing. Taking the test immediately after lying in bed or sitting for
a long period of time might result in a slight change in the test results. This is because body water tends to
move to the lower body as soon as the person stands or gets up.
• Do not eat before testing. In cases where the examinee has already eaten, the test should be put off for at least
two hours after the meal. This is because food mass is included in the examinee’s weight and thus, may result
in measurement errors.
• Use the bathroom before testing. Waste is not included in the body’s compositional elements, but the volume
of urine and excrement is included in the weight measurement affecting accuracy of the test results.
• Do not exercise before testing. Strenuous exercise or sharp movements can cause temporary changes in body
composition. Even light exercise can change your body composition temporarily.
• Take the test in the morning, if possible. Body water tends to gravitate towards the lower body throughout
the day, affecting accuracy of the test results.
• Thoroughly wipe the palms and soles with the InBody Tissue before testing. Testing may be difficult if the
examinee’s palms and soles are too dry or if the examinee has too many calluses.
• Avoid contact with the examinee during testing. Contact may lead to interference affecting test results.

16

270_manual_ENG_B_150608.indd 16 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
B. Test Instructions
1. Step on the footplate when the screen below is shown.
* The screens vary according to the Settings of the Administrator Menu ‘02. Self Mode/Professional Mode’.
Professional Mode: An examiner is present and guiding the examinee through the InBody Test.
Self Mode: The examinee takes the InBody Test following the instructions that are displayed on screen.

2. Weight measurement begins.

3. Input personal information.


* In Professional Mode, enter the ID.
* Input height only if using Self Mode.

Professional Mode Self Mode

17

270_manual_ENG_B_150608.indd 17 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
4. Maintain proper posture to take the test.
* Refer to ‘C. Test Posture’ for the proper posture.

5. The InBody Test begins.

Professional Mode Self Mode

6. When the test is completed, the results will be shown on screen.

Professional Mode Self Mode

18

270_manual_ENG_B_150608.indd 18 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
C. Test Posture
The examinee must maintain proper posture to have accurate test results.
* The test will proceed when there is good electrical contact.

Your arms must not touch the


sides of your body.
Keep your arms straight.

The thighs should not touch.

Hold the hand electrode so that


the 4 fingers wrap the surface
of the bottom hand electrode,
and place the thumb on the oval
electrode.

Place the heels on the rear sole Step on the footplate barefoot.
electrodes.

19

270_manual_ENG_B_150608.indd 19 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
III. Transportation and Storage
A. Cautions during Transportation
When transporting, have two people keep the InBody270 parallel to the ground.

B. Repacking Instructions
Once the InBody270 is installed, avoid transporting the equipment. If it must be transported, repack it in
the following sequence.

1. Turn off the InBody270.


2. Separate the connected adapter, cords, and cables from the equipment, and cover the InBody270 with
the polyethylene foam cover.
3. While holding the upper part lock button, fold down lower the upper part.

Polyethylene
foam cover

Lock
button

4. Put the InBody into the packing box. Place the packing pad over the equipment and tape up the
packing box.

Packing pads
Polyethylene foam cover

CAUTION NOTE DANGER

Caution
참조 주의
• Always use the protective packing materials provided by InBody when repacking.

C. Transportation and Storage Environment


1 The InBody270 should be transported or stored under the following conditions.

Temperature range -10 ~ 70℃ (14 ~ 158℉ )


Relative humidity 10 ~ 80% RH (No Condensation)
Atmospheric pressure 50 ~ 106kPa

20

270_manual_ENG_B_150608.indd 20 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
IV. Frequently Asked Questions (FAQ)
Even if no problems arise from the equipment, users may still have many questions, especially regarding
clinical procedures. Few common questions and answers are listed below. If your questions are not answered
here, please contact InBody.
* Customer contact information can be found under Settings of the Administrator Menu ‘24. Customer Service Information’.

A. Regarding the InBody


If a problem arises with the InBody270, you may first attempt to check the ‘Troubleshooting’ in the Administrator
Menu. The InBody270 can help you diagnose and solve some problems. If your problem cannot be resolved
through the ‘Troubleshooting’, please refer to the possible solutions below.

Question Answer

• My InBody270 does • Insert the power plug completely into a grounded 3-socket outlet.
not turn on.

Grounded 3-socket outlet

• When using a power surge protector, the equipment may not power on if
the power switch on the power surge protector is turned off. Check the
power surge protector which the power plug is connected to.

Power surge protector
power switch

• The problem may occur if the power cord is not completely plugged into
the adapter. Insert the power cord completely into the adapter.

• The problem may occur if you are using the power adapter that is not provide
by InBody. Always connect a power adapter (DC 12V, 3.4 A) provided
by InBody.

Power adapter Power cord

21

270_manual_ENG_B_150608.indd 21 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
Question Answer

• My touchscreen • Calibrate
the touchscreen under Settings of the Administrator Menu
is inaccurate or not ‘23. Touchscreen Alignment’.
responsive. * Press firmly to optimize touchscreen response.
• If you cannot enter the Administrator Menu due to touchscreen problems,
please restart the InBody. The InBody stores the last touchscreen alignment
and will automatically recall the previous touchscreen settings. The InBody
can also recognize if its touchscreen alignment is off screen and will
automatically take the user to the calibration screen after restarting.

•Iwould like to connect • Please refer to ‘E. Connecting Printer, Thermal Printer, Stadiometer, Blood
other equipment to the Pressure Monitor, Barcode Reader and SD400’ in section ‘I. InBody270
InBody270. Installation’ in this User’s Manual.

22

270_manual_ENG_B_150608.indd 22 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
B. Regarding the InBody Test
Some of the more common clinical questions are answered below. If additional questions or more clarification is
desired, please contact InBody.

Question Answer

• Must socks or stockings • Bare skin contact is essential in the analysis using the BIA method. Socks
be removed for the or stockings may cause a varying degree of distortion in the results. Socks
InBody Test? or stockings must be removed to obtain accurate data.

• Is it okay to wear accessories • Theideal condition for the analysis is simply standing with no clothes
(jewelry, watch, rings, etc) or and wearing no accessories. However, this may not always be possible.
metal objects while taking Therefore, we recommend that the examinee remove as many clothing items
the InBody Test? and accessories that may affect the weight as possible.

• Who cannot take the • Individualswith medical implant devices such as pacemakers, or essential
InBody Test or will have support devices such as patient monitoring systems, must not use this
difficulties taking the equipment. The currents will flow through the body during the
InBody Test? test, which may cause malfunctioning of the device or endanger lives.

• Children,amputees, or the elderly, may have trouble testing if they cannot


hold the hand electrodes or stand still on the foot electrodes.

• Can a person with metal • Theideal test methodology is where the examinee does not wear anything
implants in the body take metallic. Individuals with metallic implants may have skewed test results
the InBody Test? due to the conductivity of the metal affecting the results.

• Asthe weight of clothes and other wear affects the results of the body
composition analysis, it is strongly recommended to take off any heavy
clothing or metallic wear. Except for the weight, jewelry does not effect
the body composition analysis, as the contact point with the InBody270
are hands and feet.

• I have limited mobility • It


is impossible to test if an individual cannot maintain contact with the
and cannot maintain proper hand or foot electrodes. InBody has a line of products that conduct body
posture for the InBody Test. composition analysis on bed ridden examinees that allow the patients to
How can I still be tested? stay in bed. For more information, please contact InBody.

• Isthe electric current • The physiological electric impedance method uses safe low level currents
harmful to the body? that is not harmful to the body. The safety of the InBody has been tested
and proven. The InBody products have been approved for medical use by
the CE and all over the world. Many medical institutions around the world
are actively using the InBody.

• How often should I take • Individualswho are undergoing any programs that may affect their body
the InBody Test? composition are strongly recommended to have the InBody Test done every two
to four weeks.

• Consistent testing will allow individuals to track and monitor their progress
over time.

• What are the precautionary • Please refer to ‘A. Precautionary Steps’ in section ‘II. InBody Test’ in this
steps to ensure accuracy of User’s Manual.
the InBody Test?

23

270_manual_ENG_B_150608.indd 23 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
V. Others
* The InBody270 is manufactured according to the quality management procedure of InBody. InBody complies with the ISO9001 and
ISO13485 which are international quality management systems.
* This equipment satisfies the IEC60601-1 (EN60601-1), an international safety standard for electronic medical equipment. This equipment
also satisfies the IEC60601-1-2 (EN60601-1-2), an international standard for electromagnetic conformity.

A. Exterior and Functions


The following are the names and functions of each part of the InBody.
* Please inspect each component of the InBody270 for damage prior to installation.

1. Upper Part
❶ Hand electrode pipe: The signal cables connecting to the electrode are in this pipe.

❷ Hand electrode: Examinee holds the hand electrode so that the 4 fingers wrap the surface of the
bottom hand electrode while the thumb is placed on the oval electrode.
❸ Body: Connects the upper part of the equipment to the lower part.

❹ LCD screen: Shows each stage of the test, instructions, test results, etc. You can touch the screen to
input the data required for the test, configure settings, or view test results.
❺ Number keypad: Used for inputting age, height, and other number-based data.

❻ Setup button : Used for entering ‘Settings’ under the Administrator Menu when no one is on the footplate.

❼ Function button: Used for entering ‘Troubleshooting’ under the Administrator Menu when no one is on
the footplate.
❽ Print button: Used for printing the test results.

❾ Decimal point button: Used for inputting the decimal point in ID, height, age, or weight.

❿ Gender buttons: Used for selecting gender (Male or Female).

⓫ Enter button: Used to finish inputting data or to save changes in Administrator Menu.

⓬ Delete button: Used for deleting inputted data.

❶ ❺


❼ ❿

❷ ⓫

24

270_manual_ENG_B_150608.indd 24 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
2. Footplate
❶ Front sole electrode: The examinee makes contact with this electrode by stepping with the front part of their foot.
❷ Rear sole electrode: The examinee makes contact with this electrode by stepping with the heel of their foot.
❸ Footplate: This is connected to the scale, which measures the examinee’s weight.
❹ Level Indicator: Indicates the current horizontal level of the InBody270.
❺ Hinge: Joins the upper part and lower part of the equipment together.
❻ Leveling screws: Used for adjusting the horizontal level of the equipment.




25

270_manual_ENG_B_150608.indd 25 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
3. Rear Panel
❶ Speaker: Provides audible indication for test in progress, test complete and successfully saved setting changes.
❷ 9-pin COM serial port (Female, RS-232C): Used for connecting the InBody270 to Lookin’Body installed
on a computer, a stadiometer, a blood pressure monitor and SD400.
* The InBody270 can be connected to Lookin’Body installed on a computer using one of the ports ❷, ❸, or ❹.
* Only compatible with a InBody Stadiometer, Blood Pressure Monitor, and SD400.

❸ LAN port (10T Base): Used for connecting the InBody270 to Lookin’Body installed on a computer.
* The InBody270 can be connected to Lookin’Body installed on a computer using one of the ports ❷, ❸, or ❹.

❹ USB SLAVE port: Used for connecting the InBody270 to Lookin’Body installed on a computer.
* The InBody270 can be connected to Lookin’Body installed on a computer using one of the ports ❷, ❸, or ❹.

❺ USB HOST port: Used for connecting to a printer, a barcode reader, or a USB Thumb Drive.
❻ Power Inlet: Used for connecting the power adapter.
* Always use the adapter supplied by InBody Co., Ltd..
❼ Power switch: Used to turn the device on/off.
CAUTION NOTE DANGER

Warning
참조 주의
• Do not touch signal input, signal output or other connectors, and the patient simultaneously.
• External equipment intended for connection to signal input, signal output or other connectors, shall comply
with relevant IEC Standard(e.g., IEC60950 for IT equipment and IEC60601-1 series for medical electrical
equipment). In addition, all such combination-system-shall comply with the standard IEC60601-1 and/or
IEC60601-1-1 harmonized national standard or the combination. If in doubt, contact qualified technician
or your local representative.

❻ ❷ ❺ ❸ ❹

❼ ❶

26

270_manual_ENG_B_150608.indd 26 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
B. Safety Information
Indicators

9-pin serial port (Female, RS-232C)

LAN port (10T Base)

USB port

Safety Symbols

Dangerous High Voltage

Warning, Caution

4
BF Type Equipment

4
Adapter

4
4 Power On
44

4
Power Off
4

Etc. Symbols

0120 SN
European Conformity SN Serial number
0120
0120 SN
Manufacturer Direct current

EC REP EC REP
Authorized
SN representative in the
EC 0120
REP
0120 SN Operating instructions
EUROPEAN COMMUNTY

EC REP
EC REP

Disposal of old Electrical & Electronic Equipment


(Application in the European Union and other European countries with separate collection system.) This
symbol indicates that this product shall not be treated as household waste. Instead, it shall be handed over to the
applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is
disposed of correctly, you will help prevent potential negative consequences for the environment and human
health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed
information about recycling this product, please refer to local governing ordinances and recycling plans.

27

270_manual_ENG_B_150608.indd 27 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
Follow instructions for use
Suivez les instructions d’utilisation

WARNING
Electric shock hazard – do not dismantle.
Dismantling will void the warranty.

AVERTISSEMENT
Risque de choc électrique - ne pas démonter.
Le démontage annulera la garantie.

DANGER
Do not use this equipment with electrical medical device such as a pacemaker.
Ne pas utiliser cet équipement avec des appareils médicaux électriques comme un stimulateur cardiaque.

CAUTION
Do not spray any liquid substance directly onto the device.
Ne pulverisez aucune substances liquids directement sur l’appareil.

CAUTION
No excessive force on shoulder joint
Ne pas appliquer de force excessive sur les bars articulés.

28

270_manual_ENG_B_150608.indd 28 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
C. Classification
Body Composition Analyzer of Direct Segmental Multi-frequency Bioelectrical Impedance Analysis Method
• Type of protection against electric shock: Class I
• Type of the applied parts: BF Type
• Degree of protection against water infiltration: IPX0
• EMC Immunity: Level A
• EMC Emission: Level A
• Equipment is not suitable for use in the presence of flammable mixtures.

D. Specifications
Bioelectrical 10 Impedance Measurements by Using 2 Different Frequencies
Bioelectrical
Impedance Analysis (BIA) (20kHz, 100kHz) at Each of 5 Segments (Right Arm, Left Arm,
Impedance (Z)
Measurement Items Trunk, Right Leg, and Left Leg)

Electrode Method Tetrapolar 8-Point Tactile Electrodes

Measurement Method Direct Segmental Multi-frequency Bioelectrical Impedance Analysis Method (DSM-BIA )
Simultaneous Multi-frequency Impedance Measurement (SMF-BIA)

Body Composition
No Empirical Estimation
Calculation Method

Outputs Results and Interpretations


(InBody Results Sheet) • Body Composition Analysis (Total Body Water, Protein, Soft Lean Mass, Minerals,
Fat Free Mass, Body Fat Mass, Weight)
• Muscle-Fat Analysis (Weight, Skeletal Muscle Mass, Body Fat Mass)
• Obesity Analysis (Body Mass Index, Percent Body Fat)
• Segmental Lean Analysis (Right Arm,Left Arm, Trunk, Right Leg, Left Leg)
• Segmental Fat Analysis (Right Arm, Left Arm, Trunk, Right Leg, Left Leg)
• Body Composition History (Weight, Skeletal Muscle Mass, Percent Body Fat)
• InBody Score
• Weight Control (Target Weight, Weight Control, Fat Control, Muscle Control)
• Nutrition Evaluation (Protein, Minerals, Fat Mass)
• Obesity Evaluation (BMI, Percent Body Fat)
• Body Balance Evaluation (Upper, Lower, Upper-Lower)
• Waist-Hip Ratio (Graph)
• Visceral Fat Level (Graph)
• Research Parameters (Skeletal Muscle Mass, Fat Free Mass, Basal Metabolic Rate,
Waist-Hip Ratio, Waist Circumference, Visceral Fat Level, Obesity Degree, Recommended
calorie intake per day, Calorie Expenditure of Exercise, Blood Pressure (Systolic, Diastolic,
Pulse, Mean Artery Pressure, Pulse Pressure, Rate Pressure Product))
Results Interpretation QR Code
Impedance (Each segment and each frequency)

Outputs Results and Interpretations


(InBody Result Sheet for •Body Composition Analysis (Total Body Water, Protein, Minerals, Body Fat Mass, Weight)
Children) •Muscle-Fat Analysis (Weight, Skeletal Muscle Mass, Body Fat Mass)
•Obesity Analysis (Body Mass Index, Percent Body Fat)
•Growth Graph (Height, Weight)
•Body Composition History (Height, Weight, Skeletal Muscle Mass, Percent Body Fat)
•Growth Score
•Obesity Evaluation (BMI, Percent Body Fat)
•Nutrition Evaluation (Protein, Minerals, Fat Mass)
•Body Balance (Upper, Lower, Upper-Lower)
•Research Parameters (Skeletal Muscle Mass, Fat Free Mass, Basal Metabolic Rate,
Child Obesity Degree, Growth Score, Blood Pressure (Systolic, Diastolic, Pulse,
Mean Artery Pressure, Pulse Pressure, Rate Pressure Product))
Results Interpretation QR Code
Impedance (Each segment and each frequency)

29

270_manual_ENG_B_150608.indd 29 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
Outputs Total Body Water, Protein, Minerals, Weight, Muscle Mass, Body Fat Mass, Percent Body Fat,
(InBody Thermal Result BMI, Basal Metabolic Rate, Waist-Hip Ratio, Waist Circumference, Visceral Fat Level,
Sheet) Segmental Lean Analysis(Right Arm, Left Arm, Trunk, Right Leg, Left Leg), Segmental
Fat Analysis(Right Arm, Left Arm, Trunk, Right Leg, Left Leg), InBody Score, Fat Control,
Muscle Control, Impedance (Each segment and each frequency)

Stadiometer from InBody, Blood pressure monitor from InBody,


Optional Equipment
Thermal printer from InBody, SD400 from InBody

Logo Name, Address, and Contact Information can be shown on the InBody Results Sheet.

Digital Results LCD Monitor, Data management software Lookin’Body

Types of Result Sheets InBody Test Results Sheet, InBody Test Results Sheet for Children,
InBody Test Thermal Results Sheet

Voice Guidance Provides audible indication for test in progress, test complete, and successfully saved settings changes.

Database Test results can be saved if the member ID is utilized. The InBody can save up to 100,000 results.

Test Mode Self Mode, Professional Mode

Administrator Menu Setup: Configure settings and manage data


Troubleshooting: Additional information to help use the InBody

USB Thumb Drive Copy, backup, or restore the InBody test data (data can be viewed on Excel or Lookin’Body
data management software)

Barcode Reader The member ID will be automatically inputted when the barcode ID is scanned.

Backup data Backup data saved in the InBody by using a USB Thumb Drive, Restore results on the
InBody from a backup file.

Applied Rating Current 200µA (±40µA)

Adapter Manufacture BridgePower Corp.

Model BPM040S12F07

Power Input AC 100 - 240V, 50 - 60Hz, 1.2A

Power Output DC 12V, 3.4A

Display Type 600 × 1024 7inch Color TFT LCD

Internal Interface Touchscreen, Keypad

External Interface RS-232C 1EA, USB HOST 2EA, USB SLAVE 1EA, LAN (10T) 1EA,
Bluetooth 1EA, Wi-Fi 1EA

Compatible Printer Laser/Inkjet Printers (Printers recommended by InBody)


* A list of printers compatible with the InBody can be found at http://www.inbodyservice.com

Dimension 356 (W) × 796 (L) × 995 (H): mm


14.0 (W) × 31.3 (L) × 39.2 (H) : inch

Equipment Weight 14kg (30.9lbs)

Testing Time About 15 seconds

Operation Environment 10 ~ 40℃, 30 ~ 75% RH, 70 ~ 106kPa

Storage Environment -10 ~ 70℃, 10 ~ 80% RH, 50 ~ 106kPa (No Condensation)

Testing Weight Range 10 ~ 250kg (22.0 ~ 551.2lbs)

Testing Age Range 3 ~ 99 years

Height Range 95 ~ 220cm (3ft. 1.4in. ~ 7ft. 2.61in.)

* Specifications may change without prior notice.

30

270_manual_ENG_B_150608.indd 30 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
E. EMC declaration
The InBody270 is intended for use in the electromagnetic environment specified below. The customer or the
user of the InBody270 should assure that it is used in such an environment.

Electromagnetic emissions
Emissions test Compliance Electromagnetic environment
The InBody270 uses RF energy only for its internal function.
RF emissions CISPR 11 Group 1 Therefore, its RF emissions are very low and are not likely to
cause any interference in nearby electronic equipment.
RF emissions CISPR 11 Class A
Harmonic emissions The InBody270 is suitable for use in all establishments,
Class A
IEC 61000-3-2 including domestic establishments and those directly connected
to the public low-voltage power supply network that supplies
Voltage fluctuations/ flicker
buildings used for domestic purposes.
emissions Complies
IEC 61000-3-3

Electromagnetic immunity – for all ME equipment and ME systems


IEC 60601
Immunity test Compliance level Electromagnetic environment
test level
Electrostatic
Floors should be wood, concrete or ceramic tile.
discharge (ESD) ± 6 kV contact ± 6 kV contact
If floors are covered with synthetic material, the
± 8 kV air ± 8 kV air
relative humidity should be at least 30 %.
IEC 61000-4-2
Electrical fast ± 2 kV for power
± 2 kV for power
transient/burst supply lines supply lines Mains power quality should be that of a typical
± 1 kV for ± 1 kV for commercial or hospital environment.
input/output lines
IEC 61000-4-4 input/output lines
± 1 kV line(s) to
Surge ± 1 kV line(s) to
line(s) line(s) Mains power quality should be that of a typical
± 2 kV line(s) to ± 2 kV line(s) to commercial or hospital environment.
IEC 61000-4-5 earth
earth
<5 % UT <5 % UT
Voltage dips, short (>95 % dip in UT) (>95 % dip in UT)
for 0,5 cycle for 0,5 cycle
interruptions and 40 % UT 40 % UT Mains power quality should be that of a typical
voltage variations (60 % dip in UT) (60 % dip in UT) commercial or hospital environment. If the
for 5 cycles for 5 cycles user of the InBody270 requires continued
on power supply
70 % UT 70 % UT operation during power mains interruptions, it is
input lines (30 % dip in UT (30 % dip in UT recommended that the InBody270 be powered
for 25 cycles for 25 cycles from an uninterruptible power supply or a battery.
<5 % UT <5 % UT
IEC 61000-4-11 (>95 % dip in UT) (>95 % dip in UT)
for 5 s for 5 s

31

270_manual_ENG_B_150608.indd 31 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
Power frequency
Power frequency magnetic fields should be at
(50/60 Hz)
3 A/m 3 A/m levels characteristic of a typical location in a
magnetic field
typical commercial or hospital environment.
IEC 61000-4-8

NOTE UT is the a.c. mains voltage prior to application of the test level.

IEC 60601
Immunity test Compliance level Electromagnetic environment
test level
Portable and mobile RF communications
equipment should be used no closer to any part
of the InBody270, including cables, than the
recommended separation distance calculated
from the equation applicable to the frequency of
the transmitter.

Recommended separation distance


d=1.2√P

Conducted RF 3 Vrms d=1.2√P 80 MHz to 800 MHz


150 kHz to 80
IEC 61000-4-6 MHz 3 Vrms d=2.3√P 800 MHz to 2.5 GHz

where P is the maximum output power rating


of the transmitter in watts (W) according
to the transmitter manufacturer and d is the
Radiated RF 3 V/m 3 V/m recommended separation distance in metres (m).
80 MHz to 2.5 Field strengths from fixed RF transmitters, as
IEC 61000-4-3 GHz determined by an electromagnetic site survey,a
should be less than the compliance level in each
frequency range.ᵇ

Interference may occur in the vicinity of


equipment
marked with the following symbol:

NOTE1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption
and reflection from structures, objects and people.

ᵃ Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land
mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with
accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey
should be considered. If the measured field strength in the location in which the InBody270 is used exceeds the
applicable RF compliance level above, the InBody270 should be observed to verify normal operation. If abnormal
performance is observed, additional measures may be necessary, such as re-orienting or relocating the InBody270.

ᵇ Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.

32

270_manual_ENG_B_150608.indd 32 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine
270_manual_ENG_B_150608.indd 33 2015. 6. 8. 18:45
Downloaded from www.Manualslib.com manuals search engine
270_manual_ENG_B_150608.indd 34 2015. 6. 8. 18:45
Downloaded from www.Manualslib.com manuals search engine
270_manual_ENG_B_150608.indd 35 2015. 6. 8. 18:45
Downloaded from www.Manualslib.com manuals search engine
www.inbody.com

ⓒ2015 InBody Co., Ltd. All rights reserved. BM-ENG-F9-B-150608

270_manual_ENG_B_150608.indd 1 2015. 6. 8. 18:45


Downloaded from www.Manualslib.com manuals search engine

You might also like