0% found this document useful (0 votes)
15 views

HBT4000 series--Quick Guide

The HBT4000 series internal resistance tester by Qingdao Hantek Electronic Co., Ltd. is designed for precise battery internal resistance measurements using an AC four terminal testing method. It includes safety precautions, product certifications, and operational guidelines, emphasizing the importance of proper usage and maintenance. The document also provides an overview of the product's features, user interface, and preparation steps before use.

Uploaded by

LaurentEunice
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
15 views

HBT4000 series--Quick Guide

The HBT4000 series internal resistance tester by Qingdao Hantek Electronic Co., Ltd. is designed for precise battery internal resistance measurements using an AC four terminal testing method. It includes safety precautions, product certifications, and operational guidelines, emphasizing the importance of proper usage and maintenance. The document also provides an overview of the product's features, user interface, and preparation steps before use.

Uploaded by

LaurentEunice
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 26

HBT4000 series

Internal resistance tester

Quick Guide

2023.12
Warranties and Declarations

Copyright

The copyright of this document belongs to Qingdao Hantek Electronic Co., LTD.

Statement

Qingdao Hantek Electronic Co., Ltd. reserves the right to amend this document without prior

notice. Qingdao Hantek Electronic Co., Ltd. promises that the information provided is correct

and reliable but does not guarantee that this document is free from errors. Before using this

product, please make sure that the specifications of relevant technical documents are the

latest effective version. If you use documents or products of Qingdao Hantek Electronic Co.,

LTD and need products, patents or works of third parties to cooperate with them, you shall

be responsible for obtaining the consent and authorization of the third parties. The above

consent and authorization shall not be the liability of Hantek.

Product certification

The Hantek certified HBT4000 series internal resistance tester meets Chinese national and

industry standards, and has passed CE certification and UKCA certification.

Contact Us

If you have any questions or uncertainties while using the products of Qingdao Hantek

Electronics Co., Ltd., you can obtain service and support through the following methods:

Email: [email protected] , [email protected]

Website: http://www.hantek.com
Safety requirement
CN

1 Safety requirement

1.1 Summary of general security issues

Read the following safety precautions carefully to avoid injury and to prevent
damage to this product or any product connected. To avoid possible dangers,
please use this product in accordance with the regulations.
⚫ Only professionally authorized personnel can perform repairs.
⚫ Use the correct power cord.
Only use the dedicated power cord recognized by the country where the product
is located.
⚫ Ground the product.
To avoid electric shocks, the product is grounded through a grounding
conductor of the power cable. The grounding conductor must be connected to
the ground before connecting the input or output terminals of the product.
Ensure that the product is properly grounded.
⚫ View all terminal rating values.
To avoid fire or excessive current, please check all rating values and signs on the
product. Please consult the product manual for details of the rating values
before connecting the product.
⚫ Do not operate with the cover open.
Do not run the product with the cover or panel open.
⚫ Avoid circuit exposure.
Do not touch exposed connectors and components after power is switched on.
⚫ Do not operate if the product is suspected to be faulty.
If you suspect that the product has been damaged, please ask qualified
maintenance personnel to check it.
⚫ Maintain proper ventilation.
⚫ Do not operate in a humid environment.
⚫ Do not operate in inflammable or explosive environment.
⚫ Please keep the product surface clean and dry.

Warning:

Equipment that meets Class A requirements may not provide adequate

protection for broadcast services in residential environments.


Safety requirement
CN

1.2 Security terms and signs

Security terms in this manual:

Warning:

Indicates that the operation may not cause immediate damage to you.

Warning:

Indicates that if you perform this operation, it may not immediately cause
damage to you.

Note:

Indicates that the operation may cause damage to the product or other property.

Safety terms on products:

Warning:
Indicates a potential hazard may be caused to you if you do not perform this
operation.

Safety signs on the product:

Environmental protection
Shell grounding
Warning usage period
terminal
identification

1.3 Measurement category

Measurement category

This instrument can be used for measurement under class I.

Warning:

This instrument is only allowed to be used in the specified measurement

class.

Measurement class definition


Safety requirement
CN

⚫ Class I refers to measurements taken on a circuit not directly connected to


the main power supply. For example, measurements made on circuits that
are not exported from a main power supply, especially from a protected
(internal) main power supply. In the latter case, the instantaneous stress will
change. Therefore, the user should understand the instantaneous capacity of
the instrument.
⚫ Class II refers to measurements taken on a circuit directly connected to low-
voltage instruments. For example, measurements made on household
appliances, portable tools, and similar equipment.
⚫ Class III refers to measurements taken on construction equipment. For
example, measurements made on switchboards, circuit breakers, circuits
(including cables, busbars, junction boxes, switches, sockets) in fixed
equipment, as well as equipment for industrial use and certain other
equipment (for example, fixed motors permanently connected to fixed
instruments).
⚫ Class IV refers to measurements taken at the source of low-voltage
equipment. For example, measurements made on electricity meters, primary
overcurrent protection equipment, and pulse control units.

1.4 Ventilation Requirement

To ensure sufficient ventilation, when using the instrument in a workbench or


rack, please ensure that there is a gap of at least 10 centimeters on both sides,
above, and behind it.

Note:

Poor ventilation can cause an increase in instrument temperature, leading to


instrument damage. Good ventilation should be maintained during use, and
ventilation openings should be regularly checked.

1.5 Work Environment

Operating temperature and humidity range

0 ℃ -40 ℃, below 80% RH (without condensation)

Storage temperature and humidity range

-10 ℃ -50 ℃, below 80% RH (without condensation)

Accuracy assurance temperature and humidity range

23 ° C ± 5 ° C, below 80% RH (without condensation)

Warning:
Safety requirement
CN

To avoid the risk of short circuits or electric shock inside the instrument, do

not operate the instrument in a damp environment.

Altitude

Operating and Non-operating: 2,000m.

This product is powered by mains conforming to installation (overvoltage)

category II.

Warning:

Ensure that no overvoltage (e.g. from lightning) reaches the product. Otherwise,
the operator may be in danger of receiving electric shock.

Installation (Overvoltage) Category Definitions.

Installation (overvoltage) category I refers to the signal level, which is suitable


for measuring terminals connected to equipment in the source circuit, where
measures have been taken to limit instantaneous voltage to the corresponding
low level.
Installation (overvoltage) category II refers to the local distribution level, which
is suitable for equipment connected to the mains (AC power supply).

Pollution Degree

Pollution Degree 2

Pollution Degree Definition

⚫ Pollution Degree 1: No pollution or only dry, nonconductive pollution


occurs. The pollution has no effect. For example, a clean room or air-
conditioned office environment.
⚫ Pollution Degree 2: Normally only nonconductive pollution occurs.
Temporary conductivity caused by condensation is to be expected. For
example, indoor environment.
⚫ Pollution Degree 3: Conductive pollution or dry nonconductive pollution
that becomes conductive due to condensation occurs. To be found in
industrial environment or construction sites (harsh environments). For
example, sheltered outdoor environment.
⚫ Pollution Degree 4: The pollution generates persistent conductivity caused
by conductive dust, rain, or snow. For example, outdoor areas.

Security level

Class 1 - Grounded products


Safety requirement
CN

1.6 Care and Cleaning

Care:

When storing or placing the internal resistance tester, do not expose the LCD
display to direct sunlight for a long time.

Cleaning:

According to the requirements of operating conditions, regularly check the


internal resistance tester and test line. Please clean the outer surface of the
instrument according to the following steps:
1) Use a lint free cloth to remove floating dust from the outside of the internal
resistance tester and test line. Please be extremely careful to avoid scratching the
smooth display filter material.
2) Clean the internal resistance tester with a soft cloth soaked in water. To clean
more thoroughly, a water solvent of 75% isopropanol can be used.

Note:

To avoid damaging the surface of the internal resistance tester or test line, do
not use any corrosive or chemical cleaning agents.

Warning:

Before re powering on, please confirm that the instrument has dried thoroughly
to avoid electrical short circuits or even personal injury caused by moisture.

1.7 Environmental precautions

The following symbols indicate that this product complies with the requirements
established by WEEE Directive 2002/96/EC.

Equipment recycling:

The production of this equipment requires the extraction and utilization of


natural resources. If the scrapping of this product is not handled properly, certain
substances contained in the equipment may be harmful to the environment or
human health. To avoid the release of harmful substances into the environment
and reduce the use of natural resources, it is recommended to use appropriate
methods to recycle this product to ensure that most materials can be correctly
reused.
Overview
CN

2 Overview
This document is used to guide users to quickly understand the front and rear
panels, user interface, and basic operating methods of the HBT4000 series
internal resistance tester.

Tip:

The latest version of this manual can be downloaded at


(http://www.hantek.com).

Document number:202312

Software version:

Software upgrade may change or increase product functionalities, please pay


attention to Hantek website for the latest version.

Document format conventions:

1 button
Use "square brackets+text (bold)" to represent the front panel buttons, for
example, [Utility] represents the "Utility" button.
2 menus
Use "menu text (bold)+blue" to represent a menu option, such as "other" to click
on the "other" option on the current operating interface of the instrument and
enter the "other" function configuration menu。
3 Operation steps
Use "->" to represent the next step. For example, [Utility] -> Other means click
Utility label before clicking Other menu.
4 Button icon

Icon Button Icon Button

Direction keys Screenshot key

Confirm key Menu softkeys

Document content agreement:

The HBT4000 series internal resistance tester includes the following models.
Unless otherwise specified, this manual uses HBT4563H as an example to explain
the HBT4000 series and its basic operations.
Overview
CN

Model Resistance Voltage Measuring Interface

resolution resolution range

HBT4561A 0.1μΩ 1μV 0~3.9kΩ/ RS232/485,USB,LAN,I

0~160V O,ANALOG OUTPUT

HBT4561H 0.1μΩ 1μV 0~3.9kΩ/ RS232/485,USB,LAN,I

0~160V O,ANALOG

OUTPUT,GPIB

HBT4562A 0.1μΩ 1μV 0~3.9kΩ/ RS232/485,USB,LAN,I

0~260V O,ANALOG OUTPUT

HBT4562H 0.1μΩ 1μV 0~3.9kΩ/ RS232/485,USB,LAN,I

0~260V O,ANALOG

OUTPUT,GPIB

HBT4563A 0.1μΩ 1μV 0~3.9kΩ/ RS232/485,USB,LAN,I

0~410V O,ANALOG OUTPUT

HBT4563H 0.1μΩ 1μV 0~3.9kΩ/ RS232/485,USB,LAN,I

0~410V O,ANALOG

OUTPUT,GPIB

HBT4564A 0.1μΩ 10μV 0~3.9kΩ/ RS232/485,USB,LAN,I

0~1300V O,ANALOG OUTPUT

HBT4564H 0.1μΩ 10μV 0~3.9kΩ/ RS232/485,USB,LAN,I

0~1300V O,ANALOG

OUTPUT,GPIB
Overview
CN

Model Resistance Voltage Measuring Interface

resolution resolution range

HBT4565A 0.1μΩ 10μV 0~3.9kΩ/ RS232/485,USB,LAN,I

0~1700V O,ANALOG OUTPUT

HBT4565H 0.1μΩ 10μV 0~3.9kΩ/ RS232/485,USB,LAN,I

0~1700V O,ANALOG

OUTPUT,GPIB

HBT4566A 0.1μΩ 10μV 0~3.9kΩ/ RS232/485,USB,LAN,I

0~2100V O,ANALOG OUTPUT

HBT4566H 0.1μΩ 10μV 0~3.9kΩ/ RS232/485,USB,LAN,I

0~2100V O,ANALOG

OUTPUT,GPIB
General inspection
CN

3 General inspection
Check transportation packaging

After receiving the internal resistance tester, the user should check the
equipment according to the following steps: check whether there is any damage
caused by transportation: if the packaging carton or foam plastic protective pad
is seriously damaged, please keep it until the whole machine and accessories
pass the electrical and mechanical tests.

Check attachments

The details of the provided attachments are explained in Appendix A: Models


and Accessories at the end of this manual. If missing or damaged attachments
are found, please contact the dealer responsible for this business.

Inspect the entire machine

If you find that the appearance of the instrument is damaged, the instrument is
not working properly, or it fails the performance test, please contact the dealer
responsible for this business.
Product Introduction
CN

4 Product Introduction
The HBT4000 series internal resistance tester is a battery internal resistance tester
with high precision, high resolution, and fast measurement characteristics. Using
the AC four terminal testing method to more accurately test the internal
resistance and voltage of the battery; 0.1μΩ Resistance resolution, minimum
voltage resolution 1μV. Ensure the credibility of the measurement; Built in
comparator function to automatically determine whether battery parameters
meet standards; Built in multiple high-speed communication interfaces, suitable
for more testing scenarios; Easy to operate, precise and fast, stable and reliable,
this battery internal resistance tester will be your best choice.

4.1 Introduction to Front Panel

1 Key switch 2 Menu soft keys

3 Directional keys 4 Plus keys, range keys, and minus

(up/down/left/right), confirm keys

key

5 Input ports 6 Function keys

7 LCD display screen 8 Restore default settings

9 Help 10 USB HOST interface


Product Introduction
CN

4.2 Introduction to Rear Panel

1 AC power socket 2 Shell grounding terminal

3 Fuse holder 4 Safety lock holes

5 USB DEVICE interface 6 LAN interface

7 EXT I/O interface 8 ANALOG OUTPUT interface

9 RS-232/485 interface 10 GPIB interface


Product Introduction
CN

4.3 User Interface Introduction

1 Range Quick Identification 2 Trigger sources

3 Sampling rates 4 Delay

5 USB icon display 6 USB device icon display

7 Network icon display 8 lock screen icons

9 Local/Remote Display 10 Voltage measurement values

11 Resistance measurement value 12 Auxiliary menu bar

13 Resistance range 14 Voltage range


Preparation before use
CN

5 Preparation before use

5.1 Connecting the power supply

This series of internal resistance testers can input AC power with specifications of
90-240 VAC, 47/63Hz, and 30VA. Please connect the internal resistance tester to
the power supply using the power cord provided in the attachment. Press the
power switch in the lower left corner of the front panel to turn on the
instrument. If the instrument is not turned on, please confirm that the power
cord is securely connected and ensure that the instrument is connected to a
powered power source.

Warning:

To avoid electric shock, please ensure that the instrument is properly grounded.

5.2 Adjusting the handle

To adjust the handle of the instrument, hold the handles on both sides of the
instrument and pull them outward, then rotate the handles.
Preparation before use
CN

5.3 Setting System Language

The internal resistance tester supports both Chinese and English menus, and
provides corresponding help information, prompt information, and interface
display.
Press [Utility] ->Other ->English to select the desired language. When selecting
"Chinese" or "English", the menu, help information, prompt messages, and
interface are displayed in Chinese or English, respectively.
Using the built-in help system
CN

6 Using the built-in help system


To obtain help information for any front panel buttons or menu soft keys, on the
measurement display interface, press the [?] button on the front panel, and then
press the button you need help with to obtain the operation prompt for that
button. Press the [?] button again to exit the help system.
Set parameter values
CN

7 Set parameter values


The parameter settings of this series of internal resistance testers support numeric
keyboard input. Parameter settings can be completed by left clicking, right
clicking, and confirmation keys. Move the cursor position by clicking the left and
right buttons, and click the confirm button [OK] to input. Move the cursor to the
enter key , then click [OK] to save and exit.

Note: If no settings are made on the numeric keyboard interface for more than 30
seconds, the instrument will automatically jump to the measurement display
interface.
Start using
CN

8 Start using
⚫ To prevent electric shock accidents, please do not short circuit the top of the
test line and the line with voltage.
⚫ Do not measure AC voltage, AC current, or DC current. Otherwise, it may
cause instrument damage or personal injury accidents.
⚫ To prevent electric shock, please confirm the rated value of the test wire
before measurement, and do not measure voltage higher than the rated
value.

8.1 Measurement Settings

Click the [Range] button to enter the measurement display interface.

Click the Type menu soft key to select categories such as V&R, Voltage, and
Resistance.

8.2 Set voltage range

1 Press the [Range] key to enter the measurement page;


2 Click on the Range (V) menu soft key;
3 Use the menu soft key to select the range and complete the voltage range
setting.

8.3 Setting the Resistance Range

1 Press the [Range] key to enter the measurement page;


2 Click on the Range (R) menu soft key;
3 Use the menu soft key to select the range and complete the setting of the
resistance range.
Start using
CN

8.4 Zeroing

Click on the [0 ADJ] key, or click on [Utility] ->Cal in sequence. After entering the
password, click on the [0 ADJ] soft key to execute zero adjustment. After
successful zero adjustment, the interface will pop up as shown in the following
figure. If zero adjustment fails, please check if the short circuit is correct, and then
perform zero adjustment until successful.
Remote Control
CN

9 Remote Control
The internal resistance tester can be remotely controlled in the following three
methods:

1、User-defined programming:

The Standard Commands for Programmable Instruments (SCPI) command can be


used to control the internal resistance tester. Please refer to HBT4000-SCPI for
detailed instructions on commands and programming.

2、 Use IO software:

The user can use the IO software to send commands for remote control of the
internal resistance tester. PC software IO provided by Keysight is recommended.
You can log in to Keysight official website (www.keysight.com) to download the
software.

operating steps:

⚫ Establish communication between internal resistance tester and computer


⚫ Run IO and search for internal resistance tester resources
⚫ Open the Remote Command Control panel and send the command

The internal resistance tester can communicate with PC through the following
interfaces:
1 Controlled through USB
2 Controlled through LAN
3 Controlled through RS232/485

The manual will provide detailed instructions on how to use the IO software
provided by Keysight to remotely control the internal resistance tester through
various interfaces.
Default value
CN

10 Default value
The default setting of the machine factory, press the [P] key can restore the
instrument state to the factory default value.

Function Default value

Range

Measurement type V&R

Voltage range Auto

Resistance range Auto

MEA

Sample Slow

Average 1

Trigger Internal

Absolute Open

Delay(ms) 1

SAVE/LOAD

Boot Set Default

STAT

Switch OFF

Data Temp 1000

COMP

Switch Close

Comp Mode Auto


Default value
CN

Function Default value

Buzzer Close

Resistance Limit

Voltage Limit

Utility

Brightness 50%

GPIB Address 2

Key tone OFF

Language Chinese

IP 192.168.1.127

MASK 255.255.255.0

IP MODE Manual

Serial-Baud 9600

Serial-Data 7

Serial-Check None

Serial-Stop 1
More Product Information
CN

11 More Product Information


1、 More Product Information

Click on [Utility] ->Sys Info, you can obtain the machine model, serial number,
software version, and hardware version.

2、 View the option information and the option installation

For more information on this product, please refer to the relevant manual (you
can download it from Hantek's official website (www.hantek.com)).
⚫ HBT4000 Series - User Manual: provides the function of this product to
introduce the operation method, remote control method, possible faults in
the use process and processing methods, and order information.
⚫ HBT4000-SCPI Programming Manual: provides the SCPI command set for this
product.
Warranty Summary
CN

12 Warranty Summary
Qingdao Hantek Electronics Co., Ltd. (hereinafter referred to as Hantek) promises
that the host and accessories of its production instruments will have no material
or process defects during the product warranty period.
During the warranty period, if the product is proven to be defective, Hantek will
provide free repair or replacement for the user. Please refer to the official website
of Hantek or the product warranty card for detailed warranty regulations. To
obtain the full text of repair services or warranty instructions, please contact the
Hantek repair center or local offices.
Except for the warranties provided in this summary or other applicable warranty
cards, Hantek Company does not provide any other express or implied warranties,
including but not limited to any implied warranties of product tradability and
suitability for special purposes. Under no circumstances shall Hantek be liable for
indirect, special or consequential losses.
4
5

地址:山东省青岛市高新区宝源路 780 号,联东 U 谷 35 号楼


总机:400-036-7077
电邮:[email protected]
电话:0532-55678770, 55678772, 55678773
邮编:266000
官网:www.hantek.com
青岛汉泰电子有限公司

You might also like