Rating Data Sheet E-105

The document provides detailed specifications and performance data for a heat exchanger unit, including fluid allocation, thermal properties, and construction details. It outlines parameters such as inlet and outlet temperatures, pressure drops, and heat exchange rates. Additionally, it includes information on the design pressure, temperature, and materials used in the construction of the unit.

Uploaded by

ivan94.h
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
35 views

Rating Data Sheet E-105

The document provides detailed specifications and performance data for a heat exchanger unit, including fluid allocation, thermal properties, and construction details. It outlines parameters such as inlet and outlet temperatures, pressure drops, and heat exchange rates. Additionally, it includes information on the design pressure, temperature, and materials used in the construction of the unit.

Uploaded by

ivan94.h
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

HEAT EXCHANGER RATING DATA SHEET Page 1

MKH Units

Service of Unit Item No.


Type AJ12U Orientation Horizontal Connected In 4 Parallel 1 Series
Surf/Unit (Gross/Eff) 4576,35 / 4493,73 m2 Shell/Unit 4 Surf/Shell (Gross/Eff) 1144,09 / 1123,43 m2
PERFORMANCE OF ONE UNIT
Fluid Allocation Shell Side Tube Side
Fluid Name
Fluid Quantity, Total 1000-kg/hr 1430,77 512,077
Vapor (In/Out) wt% 0,0 30,0 90,1 0,0
Liquid wt% 100,0 70,0 9,9 100,0
Temperature (In/Out) C 26,73 26,60 37,90 37,72
Density kg/m3 496,57 21,198 V/L 497,09 33,759 V/L 483,62 483,94
Viscosity cP 0,1013 0,0087 V/L 0,1018 0,0098 V/L 0,0571 0,0572
Specific Heat kcal/kg-C 0,6811 0,4513 V/L 0,6795 0,4596 V/L 0,7235 0,7225
Thermal Conductivity kcal/hr-m-C 0,0810 0,0163 V/L 0,081 0,0174 V/L 0,0869 0,0870
Critical Pressure kgf/cm2A
Inlet Pressure kgf/cm2A 10,123 16,004
Velocity m/s 1,48 1,60
Pressure Drop, Allow/Calc kgf/cm2 0,090 0,063
Average Film Coefficient kcal/m2-hr-C 3569,76 2231,83
Fouling Resistance (min) m2-hr-C/kcal 0,000205 0,000205
Heat Exchanged 34,4827 MM kcal/hr MTD (Corrected) 11,1 C Overdesign 10,64 %
Transfer Rate, Service 690,22 kcal/m2-hr-C Calculated 763,64 kcal/m2-hr-C Clean 1166,56 kcal/m2-hr-C
CONSTRUCTION OF ONE SHELL Sketch (Bundle/Nozzle Orientation)
Shell Side Tube Side
Design Pressure kgf/cm2G 10,546 14,970
Design Temperature C 37,90 37,90
1524

No Passes per Shell 1 2


mm

Flow Direction Upward Downward


Connections In mm 1 @ 488,951 1 @ 336,551 6095,9
mm

Size & Out mm 2 @ 590,551 1 @ 387,351


Rating Liq. Out mm @ @
Tube No. 3136 OD 19,050 mm Thk(Avg) 1,651 mm Length 6096, mm Pitch 23,812 mm Layout 60
Tube Type Plain Material CARBON STEEL Pairs seal strips 2
Shell ID 1524,00 mm Kettle ID mm Passlane Seal Rod No. 2
Cross Baffle Type PARALLEL DOUBLE-SEG. %Cut (Diam) 29;99 Impingement Plate None
Spacing(c/c) 343,198 mm Inlet 343,198 mm No. of Crosspasses 16
Rho-V2-Inlet Nozzle 563,88 kg/m-s2 Shell Entrance 370,90 Shell Exit 522,16 kg/m-s2
Bundle Entrance 1059,43 Bundle Exit 2726,05 kg/m-s2
Weight/Shell 26875,0 Filled with Water 41465,9 Bundle 16090,4 kg
Notes: Thermal Resistance, % Velocities; m/s Flow Fractions
Shell 21,39 Shellside 1,48 A 0,122
Tube 41,39 Tubeside 1,60 B 0,602
Fouling 34,54 Crossflow 1,79 C 0,014
Metal 2,68 Window 1,02 E 0,161
F 0,101

C:\Users\Herold\Downloads\28-08.htri

You might also like