Operation Manual ET Series Electronic Theodolite
Operation Manual ET Series Electronic Theodolite
FEATURES
BASY TO OPERATE
There are 6 keys that can perform any one of the functions,The
measured angle is displayed on the display panel.
The keyboard has double functions. The normal function is for angle
measurement. When the key [MODE] is pressed down, the second function
(distance measurement) is executed.
key alternately, the direction of the measured angle change from right to
left.
CONS Special function mode key.
HOLD The horizontal angle locking key. Press the key twice,
the horizontal angle is locked. Press the key again, then to return to the
former status.
MEAS Distance measurement key. Press the key to measure distance
precisely and continuously.
Press the key in special mode, the cursor in display board moves to
left.
the key to illuminate reticule and display board. Press the key again, the
illuminating lamp turns off. (The lamp will be off automatically while no
The two lines in the middle of the lines display angle or distance
measurements or a series of character message.Both right and left sides
display symbol or character representing content or unit.
V vertical angle % grade percentage
H horizontal angle G angle unit(Gon)
HR horizontal angle right HL horizontal angle left
m distance unit (meter) ft distance unit (foot)
Stope distance battery energy message
Height difference Horizontal distance
10
11
12
13
14
15
Eyepiece adjustment
(1) Remove the telescope lens cap.
(2) Point the telescope at the sky and rotate the eyepiece ring until
the reticule appears as its maximum sharpness.
●When looking into the eyepiece, avoid an intense look to prevent
parallax and eye fatigue, When it is hard to see the reticule due to
poor brightness, press( ) key to illuminate it.
16
17
Operation Display
18
19
●If vertical index auto compensation set is used, the vertical index
can be compensated. When the vertical index is larger than the
designed criterion, “b” will be displayed. Level the instrument
precisely until “b” disappears. Then the instrument is ready for
measurement.
●Setting vertical index zero is not necessary for horizontal angle
measurement.
●Vertical index zero should be set as the suggestion for vertical
angle measurement. The instrument is ready for measurement
when a vertical angle value appears.
20
21
22
(2) press R/L to change horizontal angle from right to left mode (
HL.V).
Turn the instrument counterclockwise (HL), sight at the object A
exactly, press O SET twice to set horizontal angle to 0°00’00” as the
initial zero direction. The steps san displaying contents are the same as 1
sighting at object A .
Turn the instrument counterclockwise and sight at objects B. The
displaying contents are the followings:
23
24
25
26
27
28
29
30
Notes!
The distance between reflector center and target center should be
adjusted as the same as the distance between theodolite transit axis
center to EDM transit axis center.
When calculating horizontal distance, height difference, the
vertical angle zero direction should be set as the instruction of
EDM in initial stting . For south ND series of EDM, vertical angle
should be set as zenith distance.
31
32
Adjustment
(1) If the point A does not move along the vertical line , first,
remove the eyepiece cover and you can see the four screws.
(2) Loosen the four reticule adjusting screws uniformly with an
adjusting pin. Rotate the reticule around the aiming axis, and align the
33
34
35
36
37
Adjustment
(1)Take down the protecting cover between the optical plummet
eyepiece and focusing knob.
(2)On the white paper with a cross drawn on it, mark the place of the
center mark when the instrument moves at every 90°, and mark them
A,B,C,D.
(3)Join the diagonals with lines (A,C and B,D),the intersecting point of
the two lines is called 0.
(4)Adjust the four adjusting screws of the optical plummet by an
38
39
40
41
Error messages
Display Meaning and solution
E 01 Something wrong with the horizontal disc.
Turn the power off. If happens again, the instrument
should be send to factory to be fixed.
E 02 Telescope has been totated too quickly.
Turn on the instrument again and set vertical index
zeroing.
E 03 The alidade has been rotated too quickly.
Press OSET key to clear. If the same thing happens
again, the instrument needs to be fixed.
E 04 Something wrong with the vertical disc photoelectric
transformer, the instrument needs to be fixed.
E 05 Something wrong with the horizontal disc
photoelectric transformer (I), the instrument needs to
be fixed.
E 06 Something wrong with the horizontal disc
photoelectric transformer (II), the instrument needs
to be fixed.
b Overpass the compensation range.
Level the instrument again.
42
11.ACCESSORIES
Packing case 1
Main body 1
Recharge 1
Plumb bob 1
Adjusting pin 2
Soft brush 1
Awl 1
Wrench 2
Woolen cloth 1
Operation manual 1
Dryer 1
Qualified card 1
43