0% found this document useful (0 votes)
36 views9 pages

358-010366-00 说明书FLA48250

This manual provides comprehensive guidelines for the installation, operation, and safety of the LiFePO4 battery system designed for household use. It includes features, specifications, installation procedures, and emergency protocols, emphasizing safety measures and proper handling. The battery system supports parallel connections, has a long cycle life, and is equipped with smart BMS for enhanced performance and protection.

Uploaded by

oaktharkyaw22
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views9 pages

358-010366-00 说明书FLA48250

This manual provides comprehensive guidelines for the installation, operation, and safety of the LiFePO4 battery system designed for household use. It includes features, specifications, installation procedures, and emergency protocols, emphasizing safety measures and proper handling. The battery system supports parallel connections, has a long cycle life, and is equipped with smart BMS for enhanced performance and protection.

Uploaded by

oaktharkyaw22
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

LiFePO4 Battery System for Households

358-010366-00A
1 ABOUT THIS MANUAL ..................................................................................................... 1
1.1 Purpose .................................................................................................................... 1
1.2 Scope ....................................................................................................................... 1
1.3 Safety Instructions ................................................................................................... 1
1.4 Can be Connected in Parallel ............................................................................... 1
2
2.1 Features ................................................................................................................... 2
2.2 Product Overview .................................................................................................... 2
2.3 Specifications .......................................................................................................... 4
2.4 Recommended Settings ......................................................................................... 4
3. Installation Procedure ..................................................................................................... 5
3.1 Setup Script ............................................................................................................. 5
3.2 Tools ......................................................................................................................... 5
3.3 Floor Installation with Base..................................................................................... 6
3.4 Installation Environment .......................................................................................... 6
3.5 Battery system switch operation.............................................................................. 7
3.6 Slap control operation ............................................................................................. 7
4. INSTALLATION .................................................................................................................. 9
4.1 Unpacking and Inspection ..................................................................................... 9
4.2 Mounting the Unit .................................................................................................. 9
4.3 Connection for Parallel Mode ............................................................................... 9
5. OPERATION ....................................................................................................................... 10
5.1 Switch On/Off .......................................................................................................... 10
5.2 LCD Display Icons ................................................................................................. 11
5.3 BMS Information Page .......................................................................................... 11
5.4 Fault Code Table ................................................................................................... 12
5.5 DIP Switch SW1-SW4 Description ....................................................................... 13
6. EMERGENCY SITUATIONS ..............................................................................................14
6.1 Fire .......................................................................................................................... 14
6.2 Leaking Batteries ................................................................................................... 14
6.3 Wet Batteries .......................................................................................................... 14
6.4 Damaged Batteries ................................................................................................. 14
6.5 Warranty .................................................................................................................. 14
1 ABOUT THIS MANUAL 2. INTRODUCTION
1.1 Purpose The battery system main using solar power system for family house. It also have a with to controller the
This manual describes the introduction, installation, operation and emergency situations of the battery bank. battery easily and protect our Household application timely.
Please read this manual carefully before installations and operations. Keep this manual for future reference.
1.2 Scope 2.1 Features
This manual provides safety and installation guidelines as well as information on tools and wiring.
LiFePO4:Higher safe performance and longer cycle life.
Multiple Protection:Built-in smart BMS and Breaker.
1.3 Safety Instructions Flexible Installation:Wall-Mounted or Floor-Mounted.
WARNING: This chapter contains important safety and operating instructions. Read and keep this Wide Compatibility:Compatible with leading inverter brands.
manual for future reference. High Scalability:Capacity up to 187.5kWh.
Long Warranty:7 Years.
1.Before using the unit, read all instructions and cautionary markings on the unit, the batteries and all Slap to wake:Slap the battery can wake up the screen.
appropriate sections of this manual. Built-in WIFI:Remote monitoring of battery pack data.
2. CAUTION –-- To reduce risk of injury,damage,even burst. please use it following using manual. In case
of causing personal
3. Do not disassemble the battery. Take it to a qualified service center when service or repair is required.
Incorrect re-assembly may result in a risk of fire.
2.2 Product Overview
4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning.
Turning off the unit will not reduce this risk.
5. CAUTION – Only qualified personnel can install this device with inverter.
6. For optimum operation of this battery, please follow required spec to select appropriate cable size.
7. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool Make life full of hope

to spark or short circuit batteries or other electrical parts and could cause an explosion or fire.
8. Please strictly follow installation procedure.
9. To support full output load, at least 2 sets of FLA48V for inverter larger than 6KVA in parallel connection.
10. GROUNDING INSTRUCTIONS - This System should be connected to a permanent grounded wiring A

system. Be sure to comply with local requirements.


11. NEVER cause AC output and DC input short circuited. Do not connect to the mains when DC input
short circuits.
12. Warning!! Only qualified service persons are able to service this device.
13. Battery should be installed indoor and kept away from water, high temperature mechanical force and flames.
14. Do not install the battery in any environment of temperature below 0°C or over 55°C,and humidity over 80%.
15. Do not put any heavy objects on the battery.

1.4 Can be connected in parallel


1. The batteries can be connected in parallel. Series connection is not allowed.
Use in upright position only.
2. The batteries are not allowed to connected with PWM controller for charging.
Special Attention: Due to the built-in protection board of the lithium battery pack is with
over-discharge protection function, it is strongly recommended to stop using the load when
the battery pack is over-discharged. The battery pack cannot be repeatedly activated for
discharge. Or the battery may be failed to be activated by the AC or PV activation cable
( It requires a special charging activation method), so cannot be charged. Therefore, when
the battery pack is low power, please charge the battery as soon as possible when main
power or solar energy is available.
Model FLA48250
B
Capacity 12500Wh
C
Battery Type LiFePO4
A A

F Nominal Voltage 51.2V

D G Operating Voltage 44.8-57.6V


E H Recommend Charge/Discharge Current[1] ≤150A
Recommend Charge/Discharge Power[1] ≤7,500W

I Maximum Charge/Discharge Current(15s) 200A


Maximum Charge/Discharge Power(15s) 10,000W
Depth of Discharge(DOD) ≥ 95%
Scalability Up to 15 units in parallel
Communication RS485 / CAN
Protection Level IP21
Cycle Life[2] ≥ 6000 Cycles
Charging Temperature Range 0-55°C
LCD display Discharging Temperature Range -20-55°C
Breaker Display LCD+LED
Power On/Charging indicator Installation Wall-Mounted / Floor-Mounted
Fuse Protection Built-in smart BMS, Fuse

Earth wire Warranty 7 years

Battery Positive + Net Weight 92kg

Switch Gross Weight 110kg

Product Dimension 783×450×274mm


Communication port
Package Dimension 900×570×450mm
Battery Negative -
[1] Recommend charge/discharge current/power is affected by temperature and SOC.

[2] Test conditions: 0.2C Charging/Discharging @25°C, 80% DOD.

2.4 Recommended Settings


Lithium battery pack is not same as lead-acid battery, so for the devices which you connect with the battery pack
for charging or discharging, such as inverters, MPPT charger controllers or UPS, please implement pre-settings
as recommended settings as below before you launched them.

Setting FLA48250

Max. Charging Voltage 57.6V

Floating Charging Voltage 57.6V

Max. Charging Current 150A*N

Cut-off Voltage 48V

Notes: “N” means the number of battery packs connected in parallel.


3.3 Floor Installation with Base
3. Installation Procedure Installation Location Requirements
3.1 Setup Script
Make life full of hope

Using wall mounted components, first fix the wall mounted components to the wall, and then lift the
machine onto the wall mounted components to secure it
Make life full of hope

Note:Do not use wall mounted components, place the chassis against the wall and secure it with fixing
components A

3.2 Tools

3.4 Installation Environment

Max.+50°C Min.-10°C RH.+5%~+95%

05
3.5 4. INSTALLATION
4.1 Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You
should have received the following items inside of package.

NO NAME SPECIFICATION PICTURE

1 CAN com line 1

2
Used for product transportation and
2 Lock wall components
wall fixation

Used for battery parallel connection Wire


3 Cables
diameter 25mm²
3

4
4 User manual User manual

5
5 Guarantee card Guarantee card

6
6 RS485 com line
7
3.6 Slap control operation
7
Wake up the screen: 8
When the screen is off,slap the battery pack to wake up the screen.
Switch power/current display:
8 CAN/RS485 com line

When the screen is on, slap the battery pack to switch power/current display.

4.2 Mounting the Unit


Consider the following points before selecting where to install:
• Do not mount the battery on flammable construction materials.
• The ambient temperature should be between 0°C and 45°C to ensure optimal operation.
• The recommended installation position is to be adhered to the wall vertically.
• Be sure to keep other objects and surfaces as shown in the right diagram to guarantee sufficient heat dissipation and
to have enough space for removing wires.

Please follow below steps to implement battery connection:


1. Assemble battery ring terminal based on recommended battery cable and terminal size.
2. Connect all battery packs as units requires. It’s suggested to connect at least 2 sets for inverter larger
than 8KVA in parallel connection.
Note: if you need the battery wake-up when the grid is back, connect the battery with grid use
power adapter and communication line 1 shown in the package list.
4.3 Connection for Parallel Mode
The FLA series battery support to be connected in parallel for expansion. If you need one more battery
5. OPERATION
bank to work in parallel mode, connect the battery as shown in PIC 1. Once the batteries are connected well, close the breaker to the ON block, press On/Off button to enable the
output of the battery pack.

Main Circuit

Make life full of hope

BTCB0606/BTCB0303

5.1 Switch On / Off


1.Switch on: press On/Off button to switch on the battery, then the battery will do self-inspection before
enable output. The LCD will show the SOC.
2.Switch off: press and hold On/Off button for 1to3 seconds, the battery will shut down directly.
Step : The schematic diagram of the parallel connection of three battery packs is shown in Figure 1. Description for Communication port

Picture PIN Description


Note:After completing the above steps, arbitrarily select the positive and negative poles of one of the battery packs to
output. After confirming the correct connection of the inverter, controller and battery, you can turn on any of the switches 1 Trigger-GND
and use the battery group happily.
2 Trigger-VCC
3 CANL-PCS
For pure off grid system ,the PV awake wire need to be connected with MPPT charge controller if the battery
pack is charged by solar panels only . The connection diagram as below : 4 CANH-PCS
5 RS485-B
6 RS485-A
7 CANL
8 CANH

Make life full of hope DIP SWITCH

1-4 Communication Address

5 Termination Resister
5.2 LCD Display Icons
Eg: Rated voltage is "51.2V"; model is "12.5KWH", Eg: "52.0V" / "3.90KW" / "70%" refers to battery voltage.
"01"is the countdown. power and SOC.

Function Description

Eg: "52.0V" / "120A" / "70%" refers to battery voltage. Eg:"52.0V" / "C09" / "70%" are battery voltage, fault
current and SOC. code and SOC respectively, and Fault icon constant.
current or watt Short press
A
the switch button to switch watt and current

Indicates battery level by 0-20%,21-40%,


41-60%61-80%,81-100%.(When
charging,this icon is displayed for horse
running;When discharging,the icon displays
constant).

5.4 Fault Code Table

5.3 BMS Information Page Cell overvoltage

Cell undervoltage

Eg:“515” is the software version ;“400” is the IAP


Charge overcurrent
version and temporary version;“02” is the countdown.

Discharge overcurrent

MOS overtemperature

MOS undertemperature
Cell ovetemperature
6. EMERGENCY SITUATIONS
Felicity cannot guarantee battery absolute safety.
Cell undertemperature
6.1 Fire
In case of fires, make sure that the following equipment is available near the system.
• SCBA (self-contained breathing apparatus) and protective gear in compliance with the Directive on Personal
Protective Equipment 89/686/EEC.
• NOVEC 1230, FM-200, or dioxide extinguisher
Batteries may explode when heated above 150°C. KEEP FAR AWAY from the battery if it catches fire.

6.2 Leaking Batteries


If the battery pack leaks electrolyte, avoid contact with the leaking liquid or gas. If one is exposed the leaked
substance, immediately perform the cations described below.
1. Please check whether the circuit breaker is closed; • Inhalation: Evacuate the contaminated area, and seek medical attention.
2. Please check whether the fuse is normal;
C14 Output loss • Contact with eyes: Rinse eyes with running water for 5 minutes, and seek medical attention.
3. Restart the unit, If the error happens again, please
return to repair center. • Contact with skin: Wash the affected area thoroughly with soap and water, and seek medical attention.
• Ingestion: Induce vomiting, and seek medical attention.

5.5 DIP Switch SW1-SW4 Description 6.3 Wet Batteries


DIP switch SW1-SW4 Description ① If the battery pack is wet or submerged in water, do not let people access it, and contact your supplier for help.
Sw1 SW2 SW3 SW4 Remarks DIP switch SW5 Description②
0 0 0 0 means ID=0,communication address is0x00/0x10③ SW5 Remarks 6.4 Damaged Batteries
1 0 0 0 means ID=1,communication address is0x01④ means connect Damaged batteries are not fit for use and are dangerous and must be handled with the utmost care. It may
0 1 0 0 means ID=2,communication address is0x02 1 120Ω resistor
leak electrolyte or produce flammable gas. If the battery pack seems to be damaged, pack it in its original
1 1 0 0 means ID=3,communication address is0x03 means disconnect
0 120Ω resistor container, and then return it to your supplier.
0 0 1 0 means ID=4,communication address is0x04
1 0 1 0 means ID=5,communication address is0x05
0 1 1 0 means ID=6,communication address is0x06 6.5 Warranty
1 1 1 0 means ID=7,communication address is0x07 Products that are operated strictly in accordance with the user manual are covered by the warranty. Any
0 0 0 1 means ID=8,communication address is0x08 violation of this manual may void the warranty.
1 0 0 1 means ID=9,communication address is0x09 Limitation of Liability
0 1 0 1 means ID=10,communication address is0x0A Any product damage or property loss caused by the following conditions, Felicity does not assume any direct
1 1 0 1 means ID=11,communication address is0x0B
or indirect liability.
0 0 1 1 means ID=12,communication address is0x0C
• Product modified, design changed or parts replaced.
1 0 1 1 means ID=13,communication address is0x0D
• Changed, or attempted repairs and erasing of series number or seals;
0 1 1 1 means ID=14,communication address is0x0E
1 1 1 1 means ID=15,communication address is0x0F • System design and installation are not in compliance with standards and regulations;
Remark①: 1 in SW1-SW5 indicates ON status, and 0 indicates OFF status. • The product has been improperly stored in end user’s premises;
Remark②: When multiple battery packs communicate, the last battery pack SW5 needs to be in the ON • Transport damage (including painting scratch caused by movement inside packaging during shipping). A
status, otherwise the communication may have interference.
claim should be made directly to shipping or insurance company.
Remark③: When the battery pack ID is set to 0, it means stand-alone operation, and it is not necessary to
detect whether the parallel condition is satisfied ⑤
Remark④: When the battery pack ID is set to 1-15, it means that the parallel operation is required, and it is
necessary to detect whether the parallel condition is satisfied ⑤
Remark⑤: The parallel condition is that the difference between the battery voltage of the local battery and
all the battery pack voltages is <3V, otherwise wait until the condition is satisfied