0% found this document useful (0 votes)
3 views

Worcester MT10 Mechanical Programmer Installation and Servicing Instructions

The document provides safety instructions for the installation and operation of the MT 10 timer, emphasizing the need for an approved installer and cautioning against connecting the timer to the mains supply. It includes detailed diagrams and specifications related to the timer's functionality. The document is published by Worcester Heat Systems Ltd.

Uploaded by

pablo
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3 views

Worcester MT10 Mechanical Programmer Installation and Servicing Instructions

The document provides safety instructions for the installation and operation of the MT 10 timer, emphasizing the need for an approved installer and cautioning against connecting the timer to the mains supply. It includes detailed diagrams and specifications related to the timer's functionality. The document is published by Worcester Heat Systems Ltd.

Uploaded by

pablo
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

8 716 106 641 GB (04.

09) Gm

MT 10
7716 192 036

6 7 2 0 6 1 1 7 9 2 -0 0 .1 R
24 Hour
MT 10

Safety Instructions
B These instructions must be observed to ensure proper functioning of the timer.
B The timer should only be fitted by an approved installer.
B The timer must not be connected to the 230 V mains supply.

CAUTION, ISOLATE MAINS ELECTRICITY SUPPLY BEFORE STARTING


ANY WORK AND OBSERVE ALL RELEVANT SAFETY PRECAUTIONS.

"Greenstar i,
Greenstar Si control panel"

3 4 3 4
2 5 2 5

1 6 1 6

max max

14 13 12
11
15
12
10
16
120

17

9
18

9 3
19

7
20

6
21

18...24 V DC
22

23 6 3
10 mA
24 1 2

on on
off
off

133 33
6 720 611 792-12.1R

1.1

2 8 716 106 641 GB (04.09)


MT 10

230V AC
6 720 611 792-03.1R

2.1

6 720 611 792-03.1R

2.2

2.
1.

3.
6 720 611 792-04.1R

4.

2.3

8 716 106 641 GB (04.09) 3


MT 10

2. 2.

1.

6 720 611 792-05.1R

2.4

5.
6.

4.
6 720 611 792-06.1R

3.

2.5

4 8 716 106 641 GB (04.09)


MT 10

16 15 14 16 15 14
17 13 17 13
18 12 18 12

12
12

19
19

11
11

20
20

10
10

21
21

9 3 9 3

9
9

22
22

8
8

23
23

7
7

24
24

6 6
6 6
1 1
5 5
2 4 2 4
3 3

6 720 611 792-11.1R

3.1

17
= 18

16 15 14
17 13
18 12
12
19

11
20

10
21

9 3
9
22

8
23

7
24

6
6
1
5
2 4
3

6 720 611 792-07.1R

3.2

8 716 106 641 GB (04.09) 5


MT 10

18

8
9 3

19

7
20

6
21

5
22

4
23 6 3
24 1 2

on

off

on =

AUTO

off =
6 720 611 792-08.1R

3.3

30
:
22
..

15
0 .

16 14
17 13
18 12
:3

12
ON 1 6

19

11
20

10
21

9 3
9
22

:3 0
8
23

... 8
24

6
6
1 5
2
30

3 4
6:
N

6 720 611 792-09.1R

3.4

6 8 716 106 641 GB (04.09)


MT 10

OF
F
8:
30

...
16
16 15

:
14

30
17 13
18 12

12
19

11
20

10
21

9 3

9
22

8
23

7
24

6
1 6 5
2 4
3

OF
F 2
2 :3 0 . . . 6 : 3 0

6 720 611 792-10.1R

3.5

8 716 106 641 GB (04.09) 7


MT 10

on off on off on off on off on off


°C °C °C °C °C °C °C °C °C °C

Worcester Heat Systems Ltd.


Cotswold Way
Warndon
Worcester WR4 9SW
Great Britain

www.worcester-bosch.co.uk