0% found this document useful (0 votes)
18 views8 pages

kickspace-installation-and-operation-manual

The KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D Installation & Operating Manual provides essential safety information, installation guidelines, and operating instructions for these heating units. It emphasizes the importance of proper electrical and water connections, as well as troubleshooting tips for common issues. The manual also includes performance data and specifications for optimal operation.

Uploaded by

Stephine Ng
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views8 pages

kickspace-installation-and-operation-manual

The KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D Installation & Operating Manual provides essential safety information, installation guidelines, and operating instructions for these heating units. It emphasizes the importance of proper electrical and water connections, as well as troubleshooting tips for common issues. The manual also includes performance data and specifications for optimal operation.

Uploaded by

Stephine Ng
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

KICKSPACE® 500, 600

600-12V, 800, 80S & 80D


INSTALLATION & OPERATING MANUAL

PLEASE LEAVE THIS MANUAL WITH THE END USER

COMPLETE HEATING SOLUTIONS


02 KICKSPACE ® 500, 600, 600-12V, 800, 80S & 80D

Contents

1.0 Safety Information 02

2.0 Installation 03

3.0 Water Connection 03

4.0 Electrical Connection 04

5.0 Controls 04

6.0 Troubleshooting 04

7.0 Appendix 05

1.0 Safety Information

The KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D MUST NOT be installed in a bathroom or
other similar high humidity area.

WARNING: KICKSPACE® 500, 600, 800, 80S & 80D models must be earthed.

For MYSON KICKSPACE® 500, 600, 600-12V, Children shall not play with the appliance.
800, 80S & 80D, a fused (3A) electrical spur with Cleaning and user maintenance shall not be made
a switch having 3mm separation on all poles must by children unless they are older than 8 years and
be provided in an easily accessible position supervised.
adjacent to the unit.
Keep the appliance and its cord out of reach of
®
For the KICKSPACE 600-12V, a fused electrical children aged less than 8 years.
spur having 3mm separation on all poles must be
Children of less than 3 years should be kept
provided in an easily accessible position adjacent
away from the unit unless continuously
to the transformer. Both the fused spur and the
supervised.
transformer must not be positioned in a
bathroom or other similar high humidity area. Children aged from 3 years and less than 8 years KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL

shall only switch on / off the appliance provided


If the supply cord to the KICKSPACE® 500, 600,
that it has been placed or installed in its normal
600-12V, 800, 80S & 80D is damaged, it must be
operating position and they have been given
replaced by the manufacturer, its service agent or
supervision or instruction concerning use of the
similar qualified persons in order to avoid a
appliance in a safe way and understand the
hazard. This appliance can be used by children
hazards involved.
aged from 8 years and above and persons with
reduced physical or mental capabilities or lack of Children aged from 3 years and less than 8 years
experience and knowledge if they have been shall not plug in, clean the appliance or perform
given supervision or instruction concerning the user maintenance.
use of the appliance in a safe way and understand
the hazards involved.
01.01.2018
KICKSPACE ® 500, 600, 600-12V, 800, 80S & 80D 03

2.0 Installation

l Before proceeding with the installation, the heating system l KICKSPACE ® 500, 600, 600-12V & 500 plinth mounting
design must be considered and the unit correctly sized to (see Fig. 2b) -

1.0
meet the heat loss requirements of the room. • As an alternative to floor mounting the unit may be fitted
into the plinth.
l Before proceeding with the installation, unpack the carton
• A suitable support must be securely fitted to the floor.
contents and check against the checklist below:
• The top of the support must be level with the lower edge of
1. KICKSPACE® unit. the cut-out when fitted.
2. Flexible hoses including isolating valves (1 pair). l KICKSPACE® 80S & 80D floor mountings (see fig. 2c) - Applies
3. Instruction manual. to 80S & 80D units in 80mm plinth height kitchen unit.
4. Warranty card. l Decide the position of the KICKSPACE®, mark out and cut the
5. Grille. plinth to the dimensions using table on page 6.

2.0
6. Screw fixing kit (with grille). l Position the KICKSPACE® under the cupboard in the required
7. Transformer (12V model only). location, with the front edge just behind the line of the plinth.
8. Connector (12V model only). l Replace the plinth and bring the KICKSPACE ® forward into
l This MYSON KICKSPACE fan convector is designed for
® the opening so the front edge projects approximately 10mm
installation in the cavity beneath kitchen cupboards on the through the plinth.
vacant floor space, or other similar locations. l Align the grille and secure it to the unit with two screws
l For KICKSPACE ® 500, 600, 600-12V & 800 a minimum of supplied (use the shorter screws). (See Fig. 3).
25mm clear headroom is required above the top of the l Secure the unit/grille to the plinth with two screws supplied
KICKSPACE® when fitted.

3.0
(use the longer screws). (See Fig. 3).
l The unit should be mounted on a clean and level floor area l Complete the electrical installation, switch on and test the
under the cupboard base. KICKSPACE® (see Fig. 3).
l KICKSPACE® 80S & 80D models can only be installed if there l When installed in a kitchen consideration should be given to
is a minimum height of 80mm from the top of the floor storage of perishable goods in the cupboard above.
covering to the underside of the kitchen unit (see Fig. 1).
l KICKSPACE ® 500, 600, 600-12V & 500 floor mounting (see
Fig. 2a) - The KICKSPACE® is normally fitted directly onto the
floor and the base of the unit is fitted with four mounting feet.

3.0 Water Connection

l The KICKSPACE® should only be used on closed circulation,


two pipe, pump assisted central heating systems. Pipework must be positioned correctly to ensure
flexible hoses are not kinked when installed
l For optimum fan convector heating performance the system
must be capable of providing sufficient hot water through the
(see Figs. 5a & 5b). Only use the hose sets
heat exchanger. This means that: supplied with this unit. Do not use old or
alternative hose sets.
1. The minimum pipe size from boiler to fan convector must
be at least 15mm. Microbore pipe MUST NOT be used.
KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL

2. Where the unit is fitted on to a system with other emitters l Connect valve ends of the flexible pipes to the KICKSPACE®.
a separate circuit for the fan convector should be Note: The direction of the arrows on the valves are not
considered to provide adequate water flow. significant in this application (see Fig. 4).
3. The system water temperature on the return of the l Open valves fully, check pipe connections for leaks and vent
KICKSPACE® must be above 43°C for the fan to switch on. the heat exchanger. A vent screw is provided to vent the heat
4. This unit is NOT suitable for one-pipe systems. exchanger.

5. Optimum performance will require effective balancing of


the whole system.
6. This unit must not be used to replace a radiator in an
existing system unless an adequate flow of water can be
guaranteed.
01.01.2018
04 KICKSPACE ® 500, 600, 600-12V, 800, 80S & 80D

4.0 Electrical Connection

WARNING: KICKSPACE® 500, 600, 800, 80S & 80D models must be earthed.

l The electrical installation must comply with local or national l If the supply cord to KICKSPACE® models 500, 600, 800, 80S
wiring regulations. and 80D is damaged, it must be replaced by the manufacturer,
its service agent or similar qualified persons in order to avoid
l This unit is supplied fitted with a 2 metre 0.75mm2 cord.
a hazard.
l For KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D a fused
l If the supply or outlet cord to KICKSPACE® 600-12V
(3A) electrical spur with a switch having 3mm separation on all
transformer is damaged, it must be replaced by the
poles must be provided in an easily accessible position
manufacturer, its service agent or similar qualified persons in
adjacent to the unit (see Fig. 6a).
order to avoid a hazard.
l For the KICKSPACE® 600-12V, a fused electrical spur having
l For the KICKSPACE® 600-12V, a connector block is supplied to
3mm separation on all poles must be provided in an easily
connect the low voltage supply from the transformer to the
accessible position adjacent to the transformer. Both the fused
supply cord fitted to the unit.
spur and the transformer must not be positioned in a bathroom
or other similar high humidity installation (see Fig. 6b).

Do not energise the electrical supply until the remaining stages of the installation have been completed.

5.0 Controls

This unit is controlled by the switches on the front of the unit The fan speed can be set to boost by switching the fan speed
(see Fig. 3). switch to II.
Ensure the electricity supply is switched on. A low speed setting is recommended for normal operation with
the higher speeds for boost heating when required.
Heating Mode
• Set the heating/fan only switch to heating Off Position
• Set fan speed control to position I Set the fan speed selector switch to the off (O) position.
• The unit will now run on low fan speed.
Fan Only Mode
The system water temperature on the return of the KICKSPACE®
must be above 43°C for the fan to switch on* If required, the KICKSPACE® can be used in summer for air
circulation without heat.
*Eg. When the mean water temperature is greater than 43°C the
fan will switch on, then when the water temperature drops below • Set the heating/fan only switch to fan only
43°C the fan will switch off. • Adjust fan speed to required setting.

Performance will depend on the water temperature at the coil and


the flow through the coil.

6.0 Troubleshooting

Once installed this fan convector becomes an integral part of a problem with this unit may be the result of system controls being
complete heating system that includes boiler, pump, other incorrectly set and can be solved easily without calling out your
emitters such as radiators and fan convectors, and a number of installer. Before calling your installer, please carry out the checks
heating controls, dependent on system complexity. An apparent listed below.
KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL

Problem Possible Causes Remedy


Unit switched off Turn on
Room thermostat not calling for heat Turn up room thermostat
Unit not switched on at fused spur Switch on at spur
Fan not working in Fuse blown at fused spur Replace fuse
heating mode Unit isolating valves shut Open valves
Water temperature of Ensure boiler, pump and other central
KICKSPACE® below 43°C heating equipment is working correctly,
if not contact your installer
Note: Operation of fan can be checked by
switching to fan only setting

If the fan convector is still faulty after checking the above, call your installer.
KICKSPACE® may have poor performance/cycle if a low water • Unit incorrectly sized for heat loss of room
temperature/flow rate is supplied, please refer to your installer as • Lack of flow to KICKSPACE® from heating system
01.01.2018

this could be from the following: • Pipe sizes/pump sized incorrectly


• System incorrectly balanced
KICKSPACE ® 500, 600, 600-12V, 800, 80S & 80D 05

7.0 Appendix

Heating Performance Data


Temperature Difference (°C)
Fan
Model Heat Output (Watts) Heat Output (Btu/h)
Speed
ΔT20 ΔT30 ΔT40 ΔT50 ΔT60 ΔT20 ΔT30 ΔT40 ΔT50 ΔT60

KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL
Normal 393 566 733 896 1056 1340 1930 2501 3057 3603
500
Boost 447 683 923 1166 1412 1524 2331 3150 3980 4817
Normal 467 729 1000 1278 1562 1592 2486 3412 4361 5330
600
Boost 607 939 1279 1625 1977 2072 3203 4363 5545 6744
Normal 467 729 1000 1278 1562 1592 2486 3412 4361 5330
600-12V
Boost 607 939 1279 1625 1977 2072 3203 4363 5545 6744
Normal 747 1077 1396 1707 2012 2550 3675 4763 5824 6864
800
Boost 845 1289 1738 2192 2649 2885 4397 5930 7478 9039
Normal 304 455 605 755 905 1037 1552 2064 2576 3088
80S
Boost 331 509 691 876 1062 1129 1737 2358 2989 3624
Normal 421 624 824 1023 1221 1436 2129 2811 3490 4166
80D
Boost 475 707 938 1169 1399 1621 2412 3200 3989 4773

Heat outputs tested in accordance with Approximate Hydraulic Resistance through Fan Convectors
BS 4856 Part 1.

01.01.2018
mm wg
Flow Rate: 340 ltr/h (75 gal/h). Litres/h
500 600 600-12V 800 80S 80D
Flow Rate Correction Factors: 455 788 1046 1046 911 592 613
455 ltr/h (100 gal/h) multiply output by 1.03. 340 488 625 625 544 372 439
227 ltr/h (50 gal/h) multiply output by 0.96. 227 231 326 326 258 207 295
113 ltr/h (25 gal/h) multiply output by 0.85. 113 82 95 95 82 95 176
Test Pressure 20 bar

4.0
Maximum Working Pressure 10 bar kPa
Litres/h
500 600 600-12V 800 80S 80D
455 7.7 10.3 10.3 8.9 5.8 6.0
340 4.8 6.1 6.1 5.3 3.6 4.3
227 2.3 3.2 3.2 2.5 2.0 2.9
113 0.8 0.9 0.9 0.8 0.9 1.7

Sound Levels Weight, Water Content and Motor Power


Sound Pressures at 2.5m (dBA) Motor Water Unit Weight 5.0
Model Model
Normal Boost Power (W) Content (l) (kg)
500 25.7 38.1 500 25 0.26 4.3
600 26.4 37.2 600 40 0.30 5.0
600-12V 29.4 39.0 600-12V* 40 0.30 7.9*
800 28.5 49.8 800 40 0.34 5.5
80S 24.5 31.4 80S 13 0.17 3.83
80D 21.8 35.6 80D 17 0.25 5.13
6.0

Sound levels tested in accordance with EN 23741. *Includes transformer.


7.0
06 KICKSPACE ® 500, 600, 600-12V, 800, 80S & 80D

7.0 Appendix (continued...)

KICKSPACE ® 500 KICKSPACE ® 600 & 600-12V KICKSPACE ® 800


View on arrow View on arrow View on arrow

Cable entries Cable entries Cable entries


54 93 54 93 54 93
67 67 67
12 12 12
24 24 24

Top view Top view Top view

82 82 82

36 Mains cable 36 Mains cable 36 Mains cable

309 309 309


Cable entry 25 Cable entry 25 Cable entry 25

129 129 129

322 376 447


FRONT GRILLE FRONT GRILLE FRONT GRILLE

101 101 101

496 550 603

KICKSPACE ® 80S KICKSPACE ® 80D


View on arrow View on arrow

Cable entries Cable entries


36 72 36 72
44 44
21 21
14 14
24.5 24.5
Top view Top view

123 123
Mains cable Mains cable
40 40
301 Cable entry 25 301 Cable entry 25

123 123

432 602
FRONT GRILLE FRONT GRILLE

80 80

560 760 KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL

Dimensions

Dimensions (mm)

Model A B

500 466 93

600 & 600-12V 520 93

800 573 93 FLOOR COVERING FLOOR COVERING

80S 530 80 80mm 80mm

80D 730 80 Fig. 1

A = Width of cutout For corresponding diagrams please


refer to Figs. 2a, 2b & 2c overleaf.
B = Height of cutout
01.01.2018
KICKSPACE ® 500, 600, 600-12V, 800, 80S & 80D 07

7.0 Appendix (continued...)

A A
A B
B B

Fig. 2a Plinth opening - floor mounting Fig. 2b Plinth opening - plinth mounting Fig. 2c Plinth opening - 80mm plinth height

Grille securing screw Flexible pipes


Heating/fan only switch
Grille securing screw

Unit securing screw

Switch for fan


Boost Isolating valves
Off
Normal
Fig. 3 Front view of unit Unit securing screw Fig. 4

WALL WALL

250
300

KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL
400
100

Fig. 5a Left hand view - suggestion only Fig. 5b Right hand view - suggestion only

Transformer

MOTOR

L
MOTOR
bl y r Mains Supply 240V br

br Fan Selector
L
Switch bl
bl
N br
g/y Fan Selector
Switch
bl

Connector
Block
01.01.2018

Chassis
Earth Fan Only/Heating
Switch Fan Only/Heating
Switch

bl bl

LOW LIMIT LOW LIMIT


THERMOSTAT THERMOSTAT
7.0

Fig. 6a KICKSPACE® 500, 600, 800, 80S & 80D wiring diagram Fig. 6b KICKSPACE® 600-12V wiring diagram
Product code and
serial number location

Product Serial Number:

COMPLETE HEATING SOLUTIONS


01.01.18

You might also like