0% found this document useful (0 votes)
2 views6 pages

Flexible_Fuelle_Escape

The document contains a Certificate of Conformance for a work order related to a part ordered by Marinsa International, confirming that the part meets all specified requirements. It includes inspection details, testing reports for air leak and penetrant tests, both of which indicated no defects. The final inspection was conducted by Freddy Joseph, with the document dated October 26, 2023.

Uploaded by

vicente_py
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
2 views6 pages

Flexible_Fuelle_Escape

The document contains a Certificate of Conformance for a work order related to a part ordered by Marinsa International, confirming that the part meets all specified requirements. It includes inspection details, testing reports for air leak and penetrant tests, both of which indicated no defects. The final inspection was conducted by Freddy Joseph, with the document dated October 26, 2023.

Uploaded by

vicente_py
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 6
‘zara, 1221 PM 23-0022: Work Oder: Cenfeate of Confrence Bellows Vy i Systems CERTIFICATE OF CONFORMANCE. Customer: Marns Intemational Date: 10/26/2023 nc. Cust. PO # (Item #): 0059572 (#1) Part #: 965-021-2015-31 Work Order #: 23-0922 Part Rev: 0 Qty Ordered: 1 Drawing #: 965-021-2015-31 Qty Inspected: 1 Drawing Rev: 0 Qty Accepted: 1 Date of Final 10/19/2023 Inspection: Inspected By: Danny Trinh Material or Process Name | Specification Number | Supplier | Lot Number ae ASTM A-36 APIt HT#GU23 | Penetrant inspect | Inspect all manual welds | BELI 023-PTR-0121-00 | AirLeak test | Leak Test @ 20PSI BEL1 | 029-ALT-0094-00 BELLOWS SYSTEMS, INC. CERTIFIES THAT THE ABOVE PARTS CONFIRMS IN ALL RESPECTS TO THE REQUIREMENTS OF THE PURCHASE ORDER, THE APPLICABLE DRAWINGS, AND SPECIFICATIONS. tps eslows.alonesions.com/procneorkorrs2023/23-0822StormName-canConfomarcekpdnerendy=yesdcentPrnt=yo8 " ze, 1221 PM 25-0922 Work Order: Ft Aric Master Work Order / 23-0922 / First Article Master Part #: 965-021-2015-31 Expansion Joint - 20" Overall Length: 14.6" Flanges: 150# 1/2" Plate, Fixed x Floating Fal Nemes Bellows Material: ASTM A240 Gr. 321 Liner Material: ASTM A240 Gr. 304 Flange Material: ASTM A36 or Equiv. Customer: Marinsa International Inc. ty Queued: Cale: Qty Ordered: 1 Cust. Due: 11/20/2023 ‘Status: Manufacturing Complete Part Rev: a Drawing Rev: z Standard Part Tolerance: X + 0.060 XX +0.030 XXX #0015 XXXX +0.015 ANGLE Datault Inspection Frequency: Op OP User OA im op 91% raving tepse Nem Tol pop Meh Em Ue Fe 205° (OA, an an on ‘Tag - + as — Dim nom Dim Nom Me eee 2000 0 v 1 Number oe = c Za 1 019° Calper 0.19 z a7 002070 2000 2 0.25* Caliper 0.25 2 v - i 070 “00 8005" Caliper 0.05 Z 7 OU REF ips eet aionaystens.con/procre\wororders/2023/23-0972StornName-staricemasterspintertiendy-yesidonPrnt-yes 2 feces eee o "© ening bsewe Hon Tol gp QA 98 on on an Pot Pome? eis in TS or Bek ee tom ET com Oh Se ‘om 706" caer 8 Z 08 80 BO Oe? Caper 0S OD 08s 00070 a aC ‘wee 00 a0 ie io 7 1H" Caper 1350080 im 0070 a a a ner Sepa ales oo 80 ore a a a oo oo zoi0 1002750" Tage a1g0 au 00 ee Bb HBO" Tae m0 00 ee 208 900" we 9 399 REP Noro a oa g mao 182 ber 25 2m 80 7am 708" Tew aoe m8 0 foes wv erik 2207168 ‘swuowauinbes eusyew gzz9 VAM Po0ax9 10 sy2ou! soBUEN SSIES IY YONI Aq pomoynoy ‘suowiavinbes euerew 2020 YAMA P92K9 40 120Ui So6ue 108 Pt IT :=PON as oe i oozizes 21359 Teal Ssunsaows Woes | 9 ae ava rorzeow sruun | (aeszz 91817 Ocvr2 Ovvon/2 2017 96812 19812 NIBELE ZHMELE ‘04a eversen tees) na _1vhonwnusads ‘zz0ze 90 o08e-259 (cos) Hd di Hodey jsa, jeualeW valemey Een Je Bellows ystems ne. Bellows 10850 sritemoore Pak Or. LEAKTEST INSPECTION Houston, TX, 77041, REPORT Systems ose ets TEAK TEST INSPECTION REPORT # G23-ALT-0084-00 WORK] 23-0922 ‘COMPANY. | Marinsa Internationaline, | SATE Fo20202 ORDER: PART NUMBER. ] 965-021-2015 ary [oT PURCHASE (0083572 (Hi) ‘ORDER # TESTING air MEDIUM INSPECTION CRITERIA: Test pressure = 20 PSIG (1.379 Bar) Hold Time = 1 min "ACCEPTANCE LEVEL: No Leaks Accapted from Welds Pressure during Hold = 20 PSIG (1.379 Bar) S.No DESCRIPTION ‘OBSERVATION ‘COMMENTS: 7 Test Start Time 08:00am Pressure Gauge Range 760 PSIG Pressure Gauge Calibration ‘oer2er2024 Expiration date Pressure During Testing 2OPSIG Pressure Held Time OF ming © | Pressure Gauge SN: 39234 REMARKS: No Air Leaks were found from the weld. Wald was inspected by spraying soap water tothe welds, INSPECTED BY: Freddy Joseph DATE: 10/20/2023 QUALITY ENGINEER Bellows Systems, Ine Y Bellows 10950 Brittmoore Park PENETRANT TEST Houston, T7708 INSPECTION REPORT Systems wwa:bellows-systems.com PENETRANT TEST INSPECTION REPORT #: 023-PTR-0127-00 WORK 70922 ‘COMPANY: Marinsa Intemational] DATE 70282023 ‘ORDER: Ine. PARTNO.[TAGNO] | 885-021-201637 FOF PARTS | OF PURCHASE ORDER # | 0059572 (#1) PROCEDURE: | TOOPROG21S | REV: |2 “AREAS INSPECTED. [3 TYPE OF PENETRANT: | VP-30 REMOVER’ | WATER DEVELOPER: D0 PENETRATION TINE: |20mins | DRY TIME | 18mins | DEVELOPMENT TIME: | 1S mins DESCRIPTION OF ARTICLE EXAMINED: Ingpected all welds. LIST OF INDICATIONS 'S.NO DESCRIPTION ‘OBSERVATION ‘COMMENTS: i PT performed on all Welds, No Indications Passed RESULTS) REMARKS: All Welds Passed. No repairs needed. WSPECTED SY. FREDDY JOSEPH dae (QUALITY ENGINEER) DATE: _10.23.2023

You might also like