0% found this document useful (0 votes)
14 views5 pages

3

The document outlines the specifications and requirements for a 2.5-ton manual goods cum passenger lift, detailing electrical circuits, structural elements, access provisions, and safety features. It includes instructions for power supply, ventilation, and the construction of reinforced concrete floors and walls, as well as the installation of guide rails and access doors. Additionally, it specifies the dimensions and cutouts necessary for the lift's operation and maintenance.

Uploaded by

sagarthakur2006
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views5 pages

3

The document outlines the specifications and requirements for a 2.5-ton manual goods cum passenger lift, detailing electrical circuits, structural elements, access provisions, and safety features. It includes instructions for power supply, ventilation, and the construction of reinforced concrete floors and walls, as well as the installation of guide rails and access doors. Additionally, it specifies the dimensions and cutouts necessary for the lift's operation and maintenance.

Uploaded by

sagarthakur2006
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

OWNER T0 PROVIDE FOLL0WING IEMS 6 0F 6

1POWER &LIGHTING CIRCUITS & SWITCHES.


2PHASE POWER SUPPLY TO BE TERMINATED WITH
ELCB & EARTHING UPTO MAIN SW. IN M/C LEVEL.
h 2 PHASE, 43 AMPS. 1NO. MAIN SWITCH IN MC ROOM
.1 NO. 15 AMPS. SWITCH FOR PERMANENT ELECTRIC
LIGHTING IN M/C LEVEL
d cONVENIENT OUTLET IN M/C ROOM FOR USE OF POWER
JOOLS TOERECTOR'S REQUIREMENT
e 1 NO. 15 AMPS. SWITCH IN M/C ROOM WITH WIRING FROM SW.
TO OUTLET LOCATED AT ELEVATION, FOR LIGHT IN CAR.
f. LIGHT FIXING & SWITCH IN PILAT1525 ABOVE THE
LOWEST LANDING
0. SUITABLE VANTILATION IN M/C LEVEL WITH SUITABLE
AIR-CONDITIONING.
h. SUITABLE PERMANENT ACCESS TO MACHINE LEVEL.
2 SUITABLE ACCESS DOOR WITH LOUVERS TO M/C LEVEL.
3. REINFORCED CONCRETE M/C ROOM STRUCTURAL FL0OR SLAB
150 THK DESIGNED TO SUS TAIN MIN. 1000 kg/m2 U.D.L.
AND IN ACCORDANCE WITH GOVERNING CODE
a. SLAB TO BE FINISHED LATER FOR AMBEDDING CONDUITS OR
TROUGH TO 50 DEPTH.
4. FIXED VERTICAL IRON LADDER IN PIT EXTENDING 760 MIN. ABOVE
LOWEST LANDING SILL.
5. SUITABLE HOISTWAY WALLS TO FIX GUIDE RAILS BRACKETS.
6. WALL POCKETS PER ERECTOR'S REQUIREMENT WHICH SHOULD BE
MADE GO0D TO FINAL FINISH FOR:
a. MACHINE HITCH & SUPPORT BEAMS.
b. RAIL BRACKET - Sa. 75
AT
c. HALL BUTTON - 050 THROUGH HOLE AT ALL LANDINGS
1100 POCKET CRS. FROM FINISH FLO0R LEVEL
THROUGH HOLE AT ALL
d. HALL POSITION INDICATOR - 50
LANDING AT 1560 FROM FINISH FL00R LEVEL
LANDINGS.
e. UNLOCKING DEVICE AT ALL
PLACE, FILLING IN AND PATCHING
f. GROUTING OF SILL IN
AROUND ENTRANCE.
EXACTLY IN PLUMB ONE ABOVE THE
7. ENTRANCE - FRAMES TO BE
ENTRANCE DIMENSIONS
0THER & SQUARE WITH HOISTWAY.
MAINTAINED.
BETWEEN FRAMES SHOULD BE
OF SET BACKS OR PROJECTIONS.
8. FLUSH HOISTWAY WALLS FREE
BE FLUSH ON HOISTWAY SIDE.
CEMENT BONDING OF BRICK OR TILES TO
CEILINGS TO BE TREATED
HOISTWAY PIT & M/C ROOM WALLS, FLOORS,
ACCUMULATION & CIRCULATION OF DUST.
& PAINTED TO MINIMISE
IMMEDIATELY UNDER BEARING PLATES
9. ADEQUA TE SUPPORTS
ALLOWANCE FOR IMPACI
LOADS INDICATED INCLUDE
PER REQUIREMENT.
10. SCAFFOLDINGS : AS
PROVIDED & FIXED IN POSITION TO
11. STEEL ITEMS JO BE ANY BEAM SHOULD NoT
ERECTOR'S REQUIREMENT. THE SPAN OF
EXCEED 10 TIMES |TS DEPTH.

M/C ROOMCUTOUTS
CUTOUT FOR
SIZE
MAIN ROP[S
a - Sa. 150
b - 65
( - SQ. 150
GOVERNOR ROPES
CONDUITS
:-2.5TON MANUAL G00DS CUM PASSENGER LIFT
sta
SITE
V.T SOLUTIONS DWG. NO. RSEPL-0122 REV. NO. 02
HT
4 OF6 RM
M/
1200 2850 MIN
200
4700
2000
CLEARANCE
1300
TOp
2000 3300 LJIFT WELL
03 DptH
2000 5000 HRH
04300
LINTEL
ENTRANCE
(TYP)
LANDING
AT
ALL
2000 3000
MAX
2200 RCC
BELOW
2000
02
20002150
2000 5000
250
2000
EEE
ta HEIGHT
2000
01 WELL
5000
2000 13800
CAR-RISE
20 B
LIFT-
19700
500
0

BKTS GUIDE
BKTS & GUIDE SPACING

Basement
500
FORCES ON RAIL
1600
-PIT
CLEARANCE
1020
BOTM.
R2 1100
800 700
F-1000 kaf

R1 - 200 kgf
R2 - 100 kgf

SECTION-BB
R1 R2
SITE :-2.5TON MANUAL GO0DS CUM PASSENGER LIFT
V.T SOLUTIONS DWG NO RSEPL-0122 REV NO 02
3 OF 6 3300 M/C ROOM WIDTH
3300 LIF T- WELL WIOTH
1490 1625

EXHAUcI FAN
(FLAP 1YPE)
2000 ABOVE FROM
MC ROOM FLOOR LVL
860 (BY OWNER)
1310

ROPE
THIMBLE-B
150 x5Nos, CUTOUT
MAIN KOPE

DEPTH
850 SHEAVE
CWT
400

WELL
ROPE HOIS TING HOOK
AT MC R0OM ROOF LEVEL
THIMBLE-A
T
DEPTH
LIF
3300 560 M/C 185
o400CAR
ROOM 425 D400CAR 665 665
SHEAVE-l SHEAVE
SHE A
VE-I
850
M/C
065mm CUTOUT 1590
3300 FOR GÖV. ROPE

160 1330

ELCB WITH DOUBLE


EARTHING
(BY OWNER
1000W6R OPENING
M/C ROOM
OUT WARDS (BYOWNER)
tONIROLLER

OPENING ALLFLOORs

MC ROOM PLAN
SITE :-2.5TON MANUAL GOODS CUM PASSENGER LIFT
V.T SOLUTIONS DWG. N0. RSEPL-0122 REV. NO. 02
FfL
2150 BELOw RCC LINTEL AT ALL FLOORS 0F
65
SVT 2000 CLEAR ENTRANCE
1300 HALL BUTTON
BRICK150
WALL WAI

FIRE

90 (UTOUT
ALARMFOR
CUTOUT
FORLOP 100x100x10
80x150x100

Grd

FL00R
2580
ENTRANCE
CLEAR
2000
TOTAL
:-2.5TON
MANUAL
SITE
DWG.NO. FRONT FRAME

WIDTH

ELEVATION (WALL
L-0122
TO
WALL)

GO0DS
BUNCH
400 90

CUM
ncV.NO
ASSENGER
BRICK
S70
WALL

02
LIFT
2 OF 6

575
1455

580
CWT.
FRAME
170
0.B.B.
SAR GUIDE RÀIL- 75 X65X 16 (2 SET)
GUIDE AAIL- 75x 65 9 - (1 SET)
CAR
INSIDE
2800
2920
PLATFORM

665
400CAR
215 L00CAR SHEAVE
SHEAVE
1625
1490
85

1465
590

S25

OPENING ALL FLOORS

1250 750

2000 ENTRANCE 4,00 BUNCH 570


80x150x100
CUTOUT FOR LOP 2500 CAR INSIDE BRICK WALL
HALL BUTTON
1190 HT FROM 2560 PLATFORM
FLOOR LEVEL. 2690 D.B.G
2820 D.B.B
3300 LIFT-WELL WIDTH 300 R

LIFT- WELL PLAN VISOLUTIONS SITE :-2.5TON MANUAL G00DS CUM PASSENGER LIFT
DWG. N0. RSEPL-0122 REV. NO. 02

You might also like