Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Notes on Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Know Your Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Suggestions for Measuring Blood Pressure . . . . . . . . . . . .5
Initial Set-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Battery Installation/Replacement . . . . . . . . . . . . . . . . .7
How to Set the Date and Time . . . . . . . . . . . . . . . . . . .8
Correct Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
How to Apply the Wrist Cuff . . . . . . . . . . . . . . . . . . .10
How to Take a Reading . . . . . . . . . . . . . . . . . . . . . .11
How to Use the Memory Function . . . . . . . . . . . . . . .14
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . .18
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
1
EN-01-19[IW1]-1 10/5/04 9:14 AM Page 2
Introduction
Thank you for purchasing the Omron IW1 Automatic Wrist Blood Pressure
Monitor.
This remarkable, compact and easy to use instrument is ideal for people who
frequently monitor their own blood pressure. The small, pre-formed wrist cuff
is very convenient and easy to apply.
With the push of a button the Omron Wrist Blood Pressure Monitor measures
your blood pressure and pulse and displays the reading on a clear digital
panel. Perfect for quick, easy readings at home, at work, and while traveling.
It also stores up to 90 sets of measurements in memory and displays an
average reading based on the three most recent measurements.
The OMRON Wrist Monitor uses the oscillometric method of blood pressure
measurement. This means the monitor detects the pulse wave vibrations in the
artery of your wrist and converts the oscillations into a digital reading.
Frequently measuring the blood pressure in your wrist will provide you and
your doctor with an accurate indication of changes in your true blood
pressure.
2
EN-01-19[IW1]-1 10/5/04 9:14 AM Page 3
Notes on Safety
The OMRON IW1 is not suitable for measuring the frequency of cardiac
pacemakers.
You should never change the dosage of medication prescribed by your doctor.
People with poor peripheral circulation may find that results for measurements
taken at the wrist vary from those taken on the upper arm.
Use the OMRON IW1 only for yourself.
Caution
Self-diagnosis of measured results and treatment are dangerous. Please follow
the instructions of your doctor.
Do not use the unit on infants or persons who cannot express their consent.
Do not use the unit for any purpose other than measuring blood pressure.
Do not use a cellular phone, or other devices that emit electromagnetic fields,
near the unit. This may result in incorrect operation of the unit.
Battery liquid may leak and damage the main unit. Please observe the
following points.
• When you are not going to use the unit for a long period of time
(approximately three months or more), take out the batteries.
• Replace old batteries with new ones immediately.
• Do not use old and new batteries together.
• Do not insert the batteries with their polarities incorrectly aligned.
3
EN-01-19[IW1]-1 10/5/04 9:14 AM Page 4
Wrist Cuff
Display
STA
ME
M
MEM Button
STO RT
P
START/STOP Button
SE
T
Display
Average Value Display Memory Value Symbol
(Displayed when viewing (Displayed when viewing
the average value for last values stored in memory.)
three measurements.)
Systolic Blood Pressure Heartbeat Symbol
Irregular Heartbeat
Diastolic Blood Pressure
Symbol
Battery Low Symbol Date/Time Display
Cuff Deflation Symbol
Pulse Display
Accessories
4
EN-01-19[IW1]-1 10/5/04 9:14 AM Page 5
Notes:
* Always wait at least 2-3 minutes before taking another blood pressure
measurement.
You may require more rest time between readings depending on your
individual physiological characteristics.
* Only use the IW1 to measure your own blood pressure since the results
of measurements are stored in memory.
* Always wrap the wrist cuff around your wrist before starting to take a
measurement.
* Do not measure your blood pressure while you are in a vehicle.
* Always measure your blood pressure on the same wrist.
5
EN-01-19[IW1]-1 10/5/04 9:14 AM Page 6
Initial Set-Up
Battery Installation/Replacement
ME
M
ST OP
AR
ST
T
SE
T
2. Insert two AAA batteries in the battery
compartment, so that their polarities match the
ME
M
ST OP
AR
ST
T
SE
T
polarities of the battery compartment as
indicated.
ME
M
Note:
ST OP
AR
ST
T
SE
T
* Make sure that the battery cover is securely in
position.
Caution:
* Use two identical 1.5V AAA batteries.
Note:
* The measurement values continue to be stored in memory even after the
batteries are replaced.
6 Battery Installation/Replacement
EN-01-19[IW1]-1 10/5/04 9:14 AM Page 7
Initial Set-Up
Battery Installation/Replacement 7
EN-01-19[IW1]-1 10/5/04 9:14 AM Page 8
Initial Set-Up
Note:
* The range for the year setting is 2004 to 2030.
If the year reaches 2030, it will return to 2004.
* If you need to reset the date and time, press the SET button until the
setting you want to adjust appears on the display, then press the MEM
button to change the setting.
Note:
* If you hold down the MEM button, the digits
will advance rapidly.
Initial Set-Up
4. Repeat steps 2 and 3 to set the month and date (day).
5. Repeat steps 2 and 3 to set the hour and minutes for the time.
Note:
* The monitor will automatically turn itself off after you press the SET
button to confirm the minute setting.
Correct Usage
How to Apply the Wrist Cuff
2. Place the wrist cuff over your left wrist with your left thumb facing upward.
3. Hold the bottom part of the wrist cuff and wrap it around the wrist while
pulling so that it fits comfortably.
MEM
MEM
STA
RT
STO
P
STA
RT
SET STO
P
SET
Make sure that the wrist cuff does not cover the protruding part of the
wrist bone (ulna) on the outside of the wrist.
Unless the wrist cuff is wrapped securely around the wrist, it may not be
possible to take correct measurements.
START
STOP
SET
STO RT
P
M
Correct Usage
3. All display symbols appear briefly on the display and the wrist cuff starts
to inflate.
Notes:
* The current time is displayed and the heartbeat symbol starts to flash
while the cuff is inflating.
* Sit still and do not talk or move until the measurement is completed.
* Keep the monitor at heart level until the measurement is completed.
* To stop measurement, press the START/STOP button at any time during
measurement.
Correct Usage
5. Press the START/STOP button to turn off the
monitor.
Important:
* Your blood pressure monitor includes an irregular heartbeat feature.
Irregular heartbeats can influence the results of the measurement. The
irregular heartbeat function automatically determines if the
measurement is usable or needs to be repeated. If the measurement
results are affected by irregular heartbeats but the result is valid, the
result is shown together with the irregular heartbeat symbol ( ). If
the irregular heartbeats cause the measurement to be invalid, no result
is shown. If the irregular heartbeat symbol ( ) is shown after you
have taken a measurement, repeat the measurement. If the irregular
heartbeat symbol ( ) is shown frequently, please notify your doctor.
Note:
* Do not use this monitor to measure blood pressure for more than one
person since the measurement values are automatically stored in
memory and an average value based on the last three measurements is
calculated.
Correct Usage
What is Arrhythmia?
A heartbeat is stimulated by electrical signals that cause the heart to contract.
Arrhythmia is a condition where the heartbeat rhythm is abnormal due to
flaws in the bio-electrical system that drives the heartbeat. Typical symptoms
are skipped heartbeats, premature contraction, an abnormally rapid
(tachycardia) or slow (bradycardia) pulse. This can be caused by heart
disease, aging, physical predisposition, stress, lack of sleep, fatigue etc.
Arrhythmia can only be diagnosed by a doctor through a special
examination.
Whether the appearance of the irregular heartbeat symbol ( ) in the results
indicates arrhythmia or not can only be determined by an examination and
diagnosis by your doctor.
If the irregular heartbeat symbol ( ) is shown frequently, please notify your
doctor. Conducting self-diagnosis and treatment based on measurement results
is dangerous. Be sure to follow the instructions of your doctor.
Correct Usage
Notes:
* To ensure that the measurement results are recorded correctly, make sure
that the date and time are set correctly before taking a measurement.
* When 90 sets of readings are stored in memory, the oldest set will be
deleted to store a new set.
* The date and time of stored readings will be alternately displayed.
1. Press the MEM button, while the average reading is displayed, to view
readings stored in memory from the most recent to the oldest.
Correct Usage
2. Press the MEM button repeatedly to cycle through the readings.
3. Press the SET button, while the average reading is displayed, to view
readings from the earliest stored in memory.
Troubleshooting
Symptom Cause Correction
Replace with new
Batteries are flat.
No display appears batteries.
when the START/STOP
button is pressed. Insert the batteries with
Batteries were inserted
the correct [+] [-]
incorrectly.
polarity.
16
EN-01-19[IW1]-1 10/5/04 9:14 AM Page 17
Troubleshooting
17
EN-01-19[IW1]-1 10/5/04 9:14 AM Page 18
18
EN-01-19[IW1]-1 10/5/04 9:14 AM Page 19
Specifications
Name : OMRON Automatic Wrist Blood Pressure Monitor
Model : IW1
Display : Digital Display
Measurement : Oscillometric method
Measurement Range : Pressure: 0 to 299 mmHg
Memory : 90 measurements with date and time
Pulse : 40 to 180 beats/min
Accuracy : Pressure; Within ±3 mmHg
Pulse rate; Within ±5% of reading
Inflation : Automatic inflation by pump
Deflation : Automatic rapid deflation
Pressure Detection : Electrostatic capacity semiconductor pressure sensor
Power supply : Two AAA batteries (LR03)
Battery Life : Approximately 300 measurements when using
alkaline batteries at room temperature of 22˚C,
three times a day and inflating to 170 mmHg
Operating Temperature
and Humidity : 10°C to 40°C, 30 to 85% RH
Storage Temperature
and Humidity : -20°C to 60°C, 10 to 95% RH
Weight of Main Unit : Approximately 110 g (not including batteries)
External Dimensions : 70 mm (w) x 54 mm (h) x 37 mm (d)
(not including the wrist cuff)
Measurable
circumference of wrist : Approximately 135 mm to 215 mm
Electric Shock
Protection : Internal power supply appliance type B
Accessories : Storage case, two AAA alkaline batteries, Instruction
manual
Note:
* These specifications, to improve performance, are subject to change
without notice.