The document outlines the footing design calculations for a project named P45, detailing various parameters such as bending moments, soil pressures, and reinforcement requirements. It includes definitions of key terms, code references, and specific calculations for shear and bending design. The analysis is based on ACI 318M - 11 standards and provides critical load combinations and permissible soil pressures.
The document outlines the footing design calculations for a project named P45, detailing various parameters such as bending moments, soil pressures, and reinforcement requirements. It includes definitions of key terms, code references, and specific calculations for shear and bending design. The analysis is based on ACI 318M - 11 standards and provides critical load combinations and permissible soil pressures.
FOOTING DESIGN CALCULATIONS 36. Mx = Bending Moment along column D in 'kNm' Project Name : P45 37. Mex = Eccentricity moment along column D Client Name : FAR 38. Mxx = Total Bending Moment along column D (Mx + Mex) Engineer Name : RSA 39. My = Bending Moment along column B in 'kNm' Design File : C:\Users\JoyAn\Desktop\PROJECTS\RSA 40. Mey = Eccentricity moment along column B DB\Elmo\Proj2\Staad\RCDC\FOOT\FOOTING.rcdx 41. Myy = Total Bending Moment along column B (My + Mey) Analysis File : C:\Users\JoyAn\Desktop\PROJECTS\RSA DB\Elmo\Proj2\Staad\p45.std 42. Muy = Factored moment along column B in 'kNm' Analysis Last Modified : 07/04/2024 10:01:11 am 43. Mux = Factored moment along column D in 'kNm' 44. Netdown = Net downward load in 'kN'
Definitions: 45. OB = Maximum permissible offset On bottom side Of column
46. OL = Maximum permissible offset On left side Of column 1. A = Plan area of footing base in 'sqmm' 47. Or = Maximum permissible offset On right side Of column 2. Ast (min) = Area of longitudinal reinforcement as per code in 'sqmm' 48. OT = Maximum permissible offset On top side Of column 3. Ast Prv = Area of tensile reinforcement provided in 'sqmm' 49. P = Axial load For footing sizing In 'kN' 4. Ast Rqd = Area of longitudinal reinforcement from bearing moment and minimum % steel provided by user and as per code in 'sqmm' 50. Pcr(axial) = Design pressure at the critical section in 'kN/sqm' 5. Av = Area of shear reinforcement required in 'sqmm/m' 51. P1 = Soil pressure at corner 1 In 'kN/sqm' 6. AvPrv = Area of shear reinforcement provided in 'sqmm/m' 52. P2 = Soil pressure at corner 2 'kN/sqm' 7. A1 = Bearing area of footing at slope of 1:2 in 'sqmm' 53. P3 = Soil pressure at corner 3 'kN/sqm' 8. A2 = C/s Area of column in 'sqmm' 54. P4 = Soil pressure at corner 4 'kN/sqm' 9. B = Width of footing base in 'mm' 55. q = Surcharge Load In 'kN/sqm' 10. Beff = Effective width of footing in 'mm' 56. sp = Spacing Between bars at outer most layer In 'mm' 11. Boff = Footing offset along B in 'mm' 57. SPu = Upward Soil Pressure In 'kN/sqm' 12. BoffB = Footing offset along B above column in plan in 'mm' 58. SPuL = Upward Soil Pressure from left 13. BoffT = Footing offset along B below column in planin 'mm' 59. SPuR = Upward Soil Pressure from right 14. B1 = Width of sloped footing at top in 'mm' 60. SPuB = Upward Soil Pressure from bottom 15. ColOff = Column offset in sloped footing in 'mm' 61. SPuT = Upward Soil Pressure from top 16. Cx = Width of column in 'mm' 62. Temp1 = Peak Hydration temperature In Degree 63. Temp2 = Seasonal Temperature Variations In Degree 17. Cy = Length of Column in 'mm' 64. Vs Capacity = Shear strength capacity Of provided shear reinforcement 'kN' 18. D = Depth of footing in 'mm' 65. Vs = Nominal shear strength provided by shear reinforcement, in 19. d = Effective Depth of footing in 'mm' 'kN' 20. Dfd = Depth of founding layer in 'm' 66. Vc = Nominal shear strength provided by concrete in 'kN' 21. Dw = Ground water level in 'm' 67. Vu = Design shear force in 'kN' 22. Ec = Modulus of elasticity of concrete in 'N/sqmm' 68. Vus = Strength of shear reinforcement in 'kN' 23. Es = Modulus of elasticity of steel in 'N/sqmm' 69. Vx = Shear along major axis in 'kN' 24. Foss = Safety factor against sliding 70. Vy = Shear along minor axis in 'kN' 25. Fosu = Safety factor against uplift 71. Waterpr = Upward water pressure in 'kN/sqm' 26. Fst = Stress in steel in 'N/sqmm' 72. Waterup = Upward force due to water in 'kN/sqm' 27. F'c = Characteristic strength of concrete in 'N/sqmm' 73. WFoot = Add. Wt. due to difference in concrete and soil density in 'kN' 28. Icr = Moment of Inertia of concrete crack section in 'mm4' 74. WFootc = Weight of footing and column with concrete density in 'kN' 29. L = Length of footing base in 'mm' 75. WSoil = Weight of soil covering footing area in 'kN' 30. Leff = Effective length of footing in 'mm' 76. y = Neutral axis depth. 31. Loff = Footing offset along L in 'mm' 77. Zx = Section modulus of footing base along L in 'mm4' 32. LoffL = Footing offset along L on left side of column in 'mm' 78. Zy = Section modulus of footing base along B in 'mm4' 33. LoffR = Footing offset along L on right side of column in 'mm' 79. Φ = Strength reduction factor in shear 34. L1 = Length of sloped footing at top in 'mm' 80. Φ1 = Strength reduction factor in concrete bearing Soil Weight, S1 = 0 kN 81. Φ1Pnb = Bearing strength of column in 'kN' Total Weight, W1 = F1 + S1 = 6.25 kN Code References: Offset Along L (Loff) = 350 mm ACI 318M - 11 Offset Along B (Boff) = 350 mm Sr.No. Item Clause / Table 1. Ptmax : 10.3.5 Check For Maximum Soil Pressure: 2. Ptmin : 7.12.2.1/10.5.4 Critical Analysis Load Combination = 34 3. Vc : 11.11.2.1 Critical Load Combination = [30] : (LOAD 3: DL) +(LOAD 4: LL) -0.71 (LOAD 1: EX) 4. Av : 11.4.7.2 Pcomb = 90.35 kN 5. Max Stirrup Spacing : 11.4.5.1 P = Pcomb + W1 6. Vs : 11.4.7.9 P = 96.6 kN 7. fs,perm : 10.6.4 8. fc,perm : 10.2.7.1 Mx = 0 kNm 9. Wcr : Eq 4.2(a) My = 0 kNm P/A = 96.6 kN/sqm Mx/Zx = 0 kN/sqm My/Zy = 0 kN/sqm Maximum Soil Pressure = 96.6 kN/sqm Design Code : ACI 318M - 11 Allowable Soil Pressure = 1.33x200 kN/sqm Footing No : FC1 = 266 kN/sqm Column No : C1 ( 300 mm X 300 mm) Analysis No : 63 Check For Minimum Soil Pressure: Critical Analysis Load Combination = 28 Concrete Grade : C21 Critical Load Combination = [24] : 0.6 (LOAD 3: DL) +0.71 Steel Grade(User Defined) : Fy415 (LOAD 1: EX) Steel Grade (Flexure design) : Fy415 Pcomb = 0.11 kN Steel Grade (Shear design) : Fy415 P = Pcomb + W1 x 0.6 Clear Cover : 75 mm P = 3.86 kN Dfd : 4m Mx = 0 kNm Dw : 1m My = 0 kNm P/A = 3.86 kN/sqm Density of Soil = 18 kN/cum Mx/Zx = 0 kN/sqm Soil Bearing Capacity = 200 kN/sqm My/Zy = 0 kN/sqm Permissible SBC Increase for EQ = 33 % Minimum Soil Pressure = 3.86 kN/sqm Permissible SBC Increase for Wind = 33 % > 0 Live Load Reduction = 0 % Permissible area of loss of contact = 0 % Design For Bending: Bottom Reinforcement Along L: Design cross section by Consider overburden : Average pressure pressure Critical Analysis Load Combination = 21 Critical Load Combination = [48] : 1.42 (LOAD 3: DL) -1.25 (LOAD 1: EX) Pu = 144.38 kN Footing Type : Pad Mux = 0 kNm Footing Size (L x B x D) : 1000mm X 1000mm X 250mm Muy = 0 kNm Without considering Effect of Water P/A = 144.38 kN/sqm Table Mx/Zx = 0 kN/sqm Footing Self Wt., F1 = 6.25 kN My/Zy = 0 kN/sqm SPu = 144.38 kN/sqm Sqrt (f'c) = 4.58 N/sqmm Deff = 167 mm Vu = SPu X (Loff - d) X B Beff = 1000 mm = 26.42 kN SPu = 144.38 kN/sqm φVc = 103.47 kN Mu = SPu X B X Loff X Loff / 2 One Way Shear Along L (Tension Case): = 8.84 kNm At face of column Ast Rqd = 500 sqmm Soil + Surcharge Load,q = 6.25 kN/sqm Ast (min) = 500 sqmm Deff = 167 mm Ast Prv (Distributed Across Total Width) = 5 - #16 @ 300 Beff = 1000 mm = 1005.3 sqmm Vu = q x Loff X B X 1.2 = 2.62 kN Bottom Reinforcement Along B: φVc = 103.47 kN Critical Analysis Load Combination = 21 Vu < φVc Critical Load Combination = [48] : 1.42 (LOAD 3: DL) -1.25 (LOAD 1: EX) Pu = 144.38 kN One Way Shear Along B: Mux = 0 kNm Critical Section @ d from Column Face Muy = 0 kNm P/A = 144.38 kN/sqm = 151 mm Mx/Zx = 0 kN/sqm Critical Analysis Load Combination = 21 My/Zy = 0 kN/sqm Critical Load Combination = [48] : 1.42 (LOAD 3: DL) -1.25 (LOAD 1: EX) Deff = 151 mm Pu = 144.38 kN Leff = 1000 mm Mux = 0 kNm SPu = 144.38 kN/sqm Muy = 0 kNm Mu = SPu X L X Boff X Boff / 2 P/A = 144.38 kN/sqm = 8.84 kNm Mx/Zx = 0 kN/sqm Ast Rqd = 500 sqmm My/Zy = 0 kN/sqm Ast (min) = 500 sqmm Ast Prv (Distributed Across Total Length) = 5 - #16 @ 300 Deff = 151 mm = 1005.3 sqmm Leff = 1000 mm Design For Shear: SPu = 144.38 kN/sqm One Way Shear Along L: Sqrt (f'c) = 4.58 N/sqmm Critical Section @ d from Column Face Vu = SPu X (Boff - d) X L = 167 mm = 28.73 kN Critical Analysis Load Combination = 21 φVc = 92.71 kN Critical Load Combination = [48] : 1.42 (LOAD 3: DL) -1.25 (LOAD 1: EX) Pu = 144.38 kN One Way Shear Along B (Tension Case): Mux = 0 kNm At face of Column Muy = 0 kNm Soil + Surcharge Load,q = 6.25 kN/sqm P/A = 144.38 kN/sqm Deff = 151 mm Mx/Zx = 0 kN/sqm Leff = 1000 mm My/Zy = 0 kN/sqm Vu = q x Boff X L X 1.2 = 2.62 kN Deff = 167 mm φVc = 92.71 kN Beff = 1000 mm Vu < φVc Critical Load Combination = [48] : 1.42 (LOAD 3: DL) -1.25 Design For Punching Shear: (LOAD 1: EX) Critical Section @ d/2 from Column Face Pu = 144.38 kN = 80 mm A2 = 0.09 sqm A1 = 1.69 sqm Critical Analysis Load Combination = 21 Base Area = 1 sqm Critical Load Combination = [48] : 1.42 (LOAD 3: DL) -1.25 (LOAD 1: EX) A1 > Base Area Pu = 144.38 kN Thus, A1 = 1 Mux = 0 kNm Modification Factor = SquareRoot(A1/A2) < = 2 Muy = 0 kNm SquareRoot(A1/A2) = 3.3333 P/A = 144.38 kN/sqm Thus, Modification Factor = 2 Mx/Zx = 0 kN/sqm Φ1 = 0.65 My/Zy = 0 kN/sqm Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X Column Area Deff = 159 mm = 2088.45 kN Leff = 459 mm Φ1Pnb > Pu, Hence Safe. Beff = 459 mm Punching Perimeter = 1836 mm Punching Area = 291924 sqmm SPu = Average Pressure = 144.38 kN/sqm Sqrt (f'c) = 4.58 N/sqmm Vu = { SPu [ (L x B)- (Leff x Beff)]} = 113.96 kN φVn = 501.66 kN φVc = 331.1 kN No Shear Vu < φVc Reinforcement Required
Design For Punching Shear (Tension Case):
At face of column Pu = -21.79 kN Deff = 159 mm Leff = 300 mm Beff = 300 mm Punching Perimeter = 1200 mm Punching Area = 190800 sqmm Vu = 21.79 kN φVn = 327.88 kN φVc = 216.4 kN Vu < φVc
Load Transfer Check For Load Transfer From Column To Footing